Quick Start Guide

It is not intended nor approved for use in an industrial or residential environment.


1.1 Contents of Package
1.2 What you will need
1.3 Identify the connector and attach the cables
All connectors are on the rear panel of the CL2300 Router.

Figure 1. All connectors are on the rear panel of the CL2300 Ethernet Extender
Connect the Line Interface
To function properly, the CL2300 must be connected using a twisted-pair, unconditioned, dry, metal wire, between 19 (0.9mm) and 26 AWG (0.4mm). Leased circuits that run through signal equalization equipment are not acceptable.
The Long Range Ethernet Extender is equipped with a RJ-45 interface jack (Line), which conforms to the T568B standard. Any standard Category 5e cable can be used to directly connect two routers. Depending on the router model, it will have a two-wire, four-wire or eight-wire interface. Observe the signal/pin relationship on the CL2300’s Line interface jack for each pair in Figure 2. Figure 4 shows the proper way to wire a cable with a RJ- 45 jack on one end and four RJ-11jacks on the other.


Figure 2. CL2300 (RJ-45) twisted pair line interface

Figure 3. CopperLink Pinout for two devices

Figure 4. RJ-45 to RJ-11 cable

2.1 Connecting Console Interface
Install the supplied RJ-45-to-RJ-45 cable with the DB9-RJ45 adapter between the CL2300 RS-232 port and an open serial port on your computer. If you need to assemble your own cable, refer to the pinout diagram in figure 5.
RJ-45 Jack Signal Name DB-9
6 DSR 1 CD 4 DTR 5 SG 2 RD (driven by access server) 3 TD (received by access server) 8 CTS (driven by access server) 7 RTS (received by access server)
Wired together (No other electrical connection)
1 2 3 4 5 6 7 8
Figure 5. DB-9-to-RJ-45 cable diagram
2.2 Connect the Ethernet Interface
The Long Range Ethernet Extender has four unshielded RJ-45 auto-MDIX10/100Base-T interfaces. These are designed to connect directly to a 10/100Base-TX network. Figure 6 shows the signal/pin relationships on this interface. You may connect this port to a hub or PC using a straight through or crossover cable that is up to 328 ft long.
2.3 Connect the PoE Interface (optional)
The RJ-45 port is an Auto-MDIX 10/100Base-T interface. This port is designed to connect directly to a 10/ 100Base-T network. Figure 6 shows the signal/pin relationships on this interface. You may connect this port to any Ethernet enabled device using a straight-through or crossover cable that is up to 328 ft long. PoE enabled devices such as IP cameras, Voice over IP (VoIP) phones and wireless access points may draw the PoE. The router injects power on the data pair pins 1/2 (PoE+) and 3/6 (PoE-) of the connector labeled “Eth 3.” The power injec- tion conforms to the 802.3af specification, and will deliver the 55 volts with a maximum of 13 watts. A 12 volt 3 amp external power supply is required for PoE.
1 TX+ (data output, PoE+)
1 2 3 4 5 6 7 8
2 TX- (data output, PoE-)
3 RX+ (data input, PoE+)
6 RX- (data input, PoE-)
Figure 6. CL230010/100Base-T RJ-45 Connector Pinout

2.4 Connect the Power Source
The Long Range Ethernet Extender does not have a power switch; it powers on once the device is plugged in.
The power connection is made via the barrel jack on the rear panel of the CL2300. No configuration is necessary for the power supply.
2.5 Router/Bridge Status LEDs
The LEDs indicate the status of power, the WAN (CopperLink) PoE, and Ethernet connections.

Table 1. CL2300 front panel LEDs

Figure 7. CL2300 front panel
The CL2300 provides a browser interface that allows you to configure and manage the Ethernet extender. After you set up the IP address for the CL2300, you can access the Web interface applications directly in your Web browser by entering the configured IP address. You can then use your Web browser to list and manage configu- ration parameters from a PC.
3.1 Connect with Web GUI

Once the network connection is established, you will be able to reach the CL2300 Web GUI. Login to the Web GUI using the following credentials in figure 8.

Figure 8. Login
The CL2300 includes a Wizard within the GUI. The Icon to the wizard is in the top right corner of your browser as it displays in figure 9.

Figure 9. Wizard Home page
Once the wizard icon is selected, you will have the options of supported set ups as shown in figure 10. Click on CL2300 Basic Setup.


Figure 10. Choose Wizard
Clicking on the CL2300 Basic Setup will bring up the most common configurations used on the CopperLink Ether- net Extenders.
Figure 11 depicts options to configure through the Basic Setup wizard.

Figure 11. Basic Setup
management).
- DHCP: The CL2300 management port will accept an IP address from a DHCP server.
- Both: This choice will assign two IP addresses (one static and one DHCP to the management port
- Management VLAN ID: (Optional) define a VLAN ID for management traffic.

- Line Type (Local or Remote): This will set the Ethernet Extender as Local or Remote. Local is typically
used at the network, Remote is typically used at the remote device or remote network. Your CopperLink 2300 when received in a 2pk is already configured one CL2300 as Local and one CL2300 as Remote.
- Service Mode: Configures the number of pairs (wires) you want to use. The CL2300 will default to the
maximum number of wires available on your version of the CopperLink. CL2301 (2-wire); CL2302 (4- wire); CL2304 (8-wire).
- Annex: Please consult support before changing this setting.
2300 is defaulted to automatically select the optimal rate based on the distance (adaptive).
On the bottom right corner of the CL2300 Basic Configuration wizard page to preview configurations and reboot. Figure 12 depicts is what you can expect to see if you click on the preview tab.

Figure 12. Configure Preview Option
When the user chooses the save and reboot option a prompt will ask you to confirm. If the configuration is cor- rect, select “Yes” as shown in figure 13.


Figure 13. Confirmation
Typically the time to reboot and reestablish a CopperLink link and pass traffic once again will be under 2 min- utes.
You can connect a PC to configure the CopperLink 2300 using the CLI.
4.1 Connect with SSH
4.2 Connect with Console
4.3 Change the IP address (default: 192.168.200.10)
Follow the command sequence below:
node~>enable node~#configure node~(cfg)#context ip router node~(ctx-ip)[router]#interface LAN node~(if-ip)[router.LAN]#no ipaddress 192.168.200.10/24 node~(if-ip)[router.LAN]#ipaddress /

4.4 Change the default username
The default username will be removed once a new one is created.
Follow the command sequence below:
node~>enable node~#configure node~(cfg)#superuser password
4.5 Save the Configuration
Follow the command sequence below:
node~>enable node~#configure node~(cfg)#copy running-config startup-config
4.6 CopperLink LINE Commands
Local and Remote: This will set the Ethernet Extender as Local or Remote. Local is typically used at the net- work, Remote is typically used at the remote device or remote network. Your CopperLink 2300 when received in a 2pk is already configured one CL2300 as Local and one CL2300 as Remote.
Annex Type: Please consult support before changing this setting.
node~(prt-line)[]# annex-type { b-g | a-f }
Line Rate Configuration: This will increase the line rate of the CL2300. Your CopperLink 2300 is defaulted to automatically select the optimal rate based on the distance (adaptive).
node(prt-line)[0/0]# payload-rate {adaptive [max ] |
}
Modulation Scheme: Note higher TC-PAM rates will increase maximum payload rates available but will decrease distance. Your CopperLink 2300 is defaulted to automatically select the optimal setting. Please consult manual for the rate reach chart to determine your optimal setting if you choose to hard set this value. Higher TC- PAM rates are ideal for shorter cable runs offering max symmetrical (upstream/downstream) speeds of 11.4 Mbps (TCPAM64) and 15.3 Mbps (TCPAM128) per pair.
node(prt-line)[0/0]# tcpam {auto(16/32) | auto(64/128) | 16 | 32 |
node~(prt-line)# port dsl 0 0
node(prt-line)# mode {local|remote} · 64 | 128}

Signal to Noise Ratio: Configures the acceptable noise margin for adaptive rate. SNR is the relative strength of the DSL signal to Noise ratio. 6dB is generally the lowest dB recommended in order for the modem to synch. As overall bandwidth increases, your signal to noise ratio decreases; the higher the number the better. Your CL2300 is defaulted at 6 giving you the highest likelihood to connect.
node(prt-line)[0/0]# snr-margin
Below 6dB bad 6dB-10dB fair 11dB-20dB good
Description: This is the description of the port/line (CopperLink connection). (Ex: "This line goes to building 4") When entering a description with spaces in the text, the description must be in quotations.
Use Profile: Configures the acceptable noise margin for adaptive rate. SNR is the relative strength of the DSL signal to Noise ratio. 6dB is generally the lowest dB recommended in order for the modem to synch.
node~(prt-dsl)[0/0]# use profile
Service Mode: Configures the number of pairs (wires) you want to use. The CL2300 will default to the maxi- mum number of wires available on your version of the CopperLink. CL2301 (2-wire); CL2302 (4-wire); CL2304 (8-wire).
node~(prt-line)[0/0]# service-mode { 2-wire | 4-wire | 6-wire | 8-
Shutdown: Disables or Enables CopperLink port(s).
Exit: Return to parent mode.
Show: Displays all the configured options of the CL2300 CopperLink port(s).
node(cfg)# show prt-line 0 0
For detailed information about configuring and operating guidance, set up procedures, and troubleshooting, refer to the CopperLink 2300 Series User Manual available online at www.patton.com/manuals

B.1 EMC
B.2 Safety
B.3 PSTN Regulatory
This equipment complies with Part 68 of FCC rules and the requirements adopted by ACTA. On the bottom side of this equipment is a label that contains—among other information—a product identifier in the format US: AAAEQ##TXXXX. If requested, this number must be provided to the telephone company.
The method used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA.
If this equipment causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinuance of service may be required. But if advance notice isn’t practical, the telephone com- pany will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.

The telephone company may make changes in its facilities, equipment, operations or procedures that could affect the operation of the equipment. If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service.
If trouble is experienced with this equipment, for repair or warranty information, please contact our company. If the equipment is causing harm to the telephone network, the telephone company may request that you discon- nect the equipment until the problem is resolved.
Connection to party line service is subject to state tariffs. Contact the state public utility commission, public ser- vice commission or corporation commission for information.
C.1 Industry Canada Notice
This equipment meets the applicable Industry Canada Terminal Equipment Technical Specifications. This is con- firmed by the registration number. The abbreviation, IC, before the registration number signifies that registra- tion was performed based on a Declaration of Conformity indicating that Industry Canada technical specifications were met. It does not imply that Industry Canada approved the equipment.
This Declaration of Conformity means that the equipment meets certain telecommunications network protective, operational and safety requirements. The Department does not guarantee the equipment will operate to the user's satisfaction. Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above condition may not prevent degradation of service in some situations. Repairs to some certified equipment should be made by an authorized maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment. Users should ensure for their own protection that the ground connections of the power utility, telephone lines and internal metallic water pipe system, are connected together. This protection may be particularly important in rural areas.
This equipment generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television recep- tion. This equipment has been tested and found to comply with the limits for a Class A computing device in accor- dance with the specifications in Subpart B of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the equipment causes interference to radio or television reception, which can be determined by disconnecting the cables, try to correct the interference by one or more of the fol- lowing measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).

We certify that the apparatus identified above conforms to the requirements of Council Directive 1999/5/EC on the approximation of the laws of the member states relating to Radio and Telecommunication Terminal Equip- ment and the mutual recognition of their conformity.
The safety advises in the documentation accompanying the products shall be obeyed. The conformity to the above directive is indicated by the CE sign on the device.
The signed Declaration of Conformity can be downloaded from www.patton.com/certifications/.
D R M Green
European Compliance Services Limited.
Oxford, OX1 1BE, UK
F.1 Copyright statement
Copyright © 2013, Patton Electronics Company. All rights reserved.
The information in this document is subject to change without notice. Patton Electronics assumes no liability for errors that may appear in this document.
F.2 Trademarks statement
The term CopperLink is a trademark of Patton Electronics Company. All other trademarks presented in this document are the property of their respective owners.
F.3 Warranty, Trademark, & Compliance Information
For warranty, trademark and compliance information, refer to the CopperLink User Manual located online at www.patton.com/manuals
In accordance with the requirements of council directive 2002/96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of- life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling.
Greyfriars Court · Paradise Square
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.