Leased-Line Extenders over IP
Getting Started Guide

Sales Office:
Technical Support:
E-mail:
support@patton.com
: Part Number:
07M2292-GS, Rev. A
Revised:
+1 (301) 975-1000 · +1 (301) 975-1007 · April 13, 2009

Patton Electronics Company, Inc.
7622 Rickenbacker Drive Gaithersburg, MD 20879 USA
are trademarks of Patton Electronics Company. All other trademarks presented in this document are the property of their respective owners.
Copyright © 2009, Patton Electronics Company. All rights reserved.
The information in this document is subject to change without notice. Patton Elec- tronics assumes no liability for errors that may appear in this document.
The software described in this document is furnished under a license and may be used or copied only in accordance with the terms of such license.
warrants all SmartNode extender components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of the shipment.
This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If the product fails to perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall
be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product.
specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.

1 General information 14
2 Applications overview 19
3 Hardware installation 21
4 Getting started with the SmartNode 32
5 LEDs status and monitoring 36
6 Contacting Patton for assistance 38
A Compliance information 41
B Specifications 43
C Cabling 46
D Port pin-outs 50
E Installation checklist 52


1 SmartNode extender (SmartNode 2294 shown) 15 2 Examples of SmartNode 2292 and 2294 Series rear panels 16 3 SmartNode 2294 power input connectors 17 4 SmartNode 2292 and 2294 front panels 18 5 Leased-line extension application 20 6 Rear view showing location of Ethernet connectors and voice ports (SmartNode 2294 shown) 26 7 Analog connection 26 8 Analog connection 27 9 RJ-11 pinout diagram 27 10 Connecting a SmartNode 2294 Series device to a hub 28 11 Connecting to a host 29 12 Power connector location on rear panel 30 13 SmartNode extender front panel LEDs and Console port locations (SmartNode 2294 shown) 31 14 Steps for setting up a new SmartNode 33 15 Connecting to the terminal 34 16 Examples of SmartNode 2292 and 2294 Series front panels 37 17 Connecting a serial terminal 47 18 Ethernet cross-over 48 19 Ethernet straight-through 49 20 Connecting an FXS device 49 21 EIA-561 (RJ-45 8-pin) port 51

1 General conventions 12 2 Rear panel ports 17 3 Installation checklist 23 4 Sample site log entries 24 5 RJ-11 socket 27 6 Ethernet 10/100Base-T (RJ-45) port pin-outs (SmartNode 2294 Series) 28 7 Factory default IP address and network mask configuration 34 8 SmartNode LED Indications 37 9 RJ-45 socket 51 10 RJ-11 socket 51 11 Installation checklist 53

This guide describes the SmartNode 2294 and 2292 Series hardware, installation and basic configuration. For detailed software configuration information refer to the
and the avail- able Configuration Notes.
SmartWare Software Configuration Guide
This guide is intended for the following users:
This guide contains the following chapters and appendices:
you install the extender.
before

Model 2292 & 2294 Series Getting Started Guide
refer to potential property damage.
relate to personal injury issues, and
Calls attention to important information.
The shock hazard symbol and WARNING heading indicate a potential electric shock hazard. Strictly follow the warning instructions to avoid injury caused by electric shock.
The alert symbol and WARNING heading indicate a potential safety hazard. Strictly follow the warning instructions to avoid personal injury.
The shock hazard symbol and CAUTION heading indicate a potential electric shock hazard. Strictly follow the instructions to avoid property damage caused by electric shock.
The alert symbol and CAUTION heading indicate a potential haz- ard. Strictly follow the instructions to avoid property damage.
About this guide

Model 2292 & 2294 Series Getting Started Guide
This device contains no user serviceable parts. The equipment shall be returned to Patton Electronics for repairs, or repaired by qualified service personnel.
Mains Voltage: Do not open the case when the power cord is connected. For systems without a power switch, line voltages are present within the power supply when the power cord is connected.
The external power adapter shall be a listed Limited Power Source. Ensure that the power cable used meets all applicable standards for the country in which it is to be installed, and that it is connected to a wall outlet which has earth ground. The mains outlet that is utilized to power the devise shall be within 10 feet (3 meters) of the device, shall be easily accessible, and pro- tected by a circuit breaker.
Hazardous network voltages are present in WAN ports regardless of whether power to the SmartNode is ON or OFF. To avoid electric shock, use caution when near WAN ports. When detaching cables, detach the end away from the SmartNode first.
Do not work on the system or connect or disconnect cables during periods of lightning activity.
Before opening the chassis, disconnect the telephone network cables to avoid contact with telephone line voltages.
In accordance with the requirements of council directive 2002/ 96/EC on Waste of Electrical and Electronic Equipment (WEEE), ensure that at end-of-life you separate this product from other waste and scrap and deliver to the WEEE collection system in your country for recycling.

Model 2292 & 2294 Series Getting Started Guide
When starting to install interface cards place the interface card on its shielded plastic bag if you lay it on your bench.
Electrostatic Discharge (ESD) can damage equipment and impair electrical circuitry. It occurs when electronic printed circuit cards are improperly handled and can result in complete or intermit- tent failures. Do the following to prevent ESD:
Always follow ESD prevention procedures when removing and replacing cards.
Wear an ESD-preventive wrist strap, ensuring that it makes good skin contact. Connect the clip to an unpainted surface of the chassis frame to safely channel unwanted ESD voltages to ground.
To properly guard against ESD damage and shocks, the wrist strap and cord must operate effectively. If no wrist strap is available, ground yourself by touching the metal part of the chassis.

Model 2292 & 2294 Series Getting Started Guide
This section describes the typographical conventions and terms used in this guide.
The procedures described in this manual use the following text conventions:
Table 1. General conventions
About this guide

Model 2292 & 2294 Series Getting Started Guide
About this guide


Model 2292 & 2294 Series Getting Started Guide
1 • General information
The SmartNode 2292 and 2294 Series Leased-Line Extenders (see figure 1) combine IP routing, VPN/Secu- rity, and Quality of Service for up to 4 transparent voice channels and FAX calls over any IP or PSTN network. Leverage low-cost IP services with packet-voice for complete branch office voice and data connectivity.

Figure 1. SmartNode extender (SmartNode 2294 shown)
The SmartNode 2292 and 2294 Leased-Line Extenders, equipped with two 10/100Base-T Ethernet ports pro- vide; voice over IP (VoIP) and Internet telephony plus Internet access routing, VPN and firewall functions, and extensive Quality of Service (QoS) functions.
The SmartNode 2292 and 2294 Leased-Line Extenders perform the following major functions:
SmartNode Series Leased-Line Extenders overview

Model 2292 & 2294 Series Getting Started Guide 1 • General information
SmartNode 2292 and 2294 Leased-Line Extenders The SmartNode 2292 and 2294 models are compact Leased-Line Extenderss over IP that support two or four VoIP channels, depending on the number of ports (see figure 2).

Figure 2. Examples of SmartNode 2292 and 2294 Series rear panels
The following base models (each equipped with two 10/100Base-T Ethernet ports) are available:
The port combinations are indicated in the extension of the model code. T he following model code conven- tions apply:
For example, the model code 2294/EUI describes a SmartNode configured as follows:
SmartNode Series Leased-Line Extenders overview 16

Model 2292 & 2294 Series Getting Started Guide 1 • General information

External power supply connector (accepts 12 VDC, 1.25 A, from external AC adapter)
Figure 3. SmartNode 2294 power input connectors
Ports descriptions The SmartNode 2292 Series rear panel ports are described in table 2.
Table 2. Rear panel ports
Rear panel RJ-45 connectors (see figure 6 on page 26) that connect the extender to an
Ethernet device (e.g., a cable or DSL modem, LAN hub or switch).
Analog voice port Rear panel FXS RJ-11(6 position, 4 wire) connectors (see figure 6 on page 26) that
connect the extender with an analog terminal. Power Rear panel The gateway is available in a DC or AC power input version (see
figure 3), labeled as follows:
Console Front panel Used for service and maintenance, the Console port (see figure 4 on page 18),
an RS-232 RJ-45 connector, connects the extender to a serial terminal such as a PC or ASCII terminal (also called a dumb terminal).
Reset button behavior The SmartNode devices have a Reset button on the rear panel. It is used as follows:
SmartNode Series Leased-Line Extenders overview 17
Port Location Description · 10/100 Ethernet

Model 2292 & 2294 Series Getting Started Guide 1 • General information

Figure 4. SmartNode 2292 and 2294 front panels
SmartNode Series Leased-Line Extenders overview 18

Typical application 20
Leased-line extension 20

Model 2292 & 2294 Series Getting Started Guide 2 • Applications overview
Leased-line extension The SmartNode 2292 and 2294 Series Leased-Line Extenders allow you to save big on leased line costs. Using only one extender on each side, audio information on up to four leased-lines can be transported over a packet- based network. This essentially ensures that with just Internet access at two locations, four leased lines between these two locations can be established.
Combine this with IP routing, VPN/Security, and Quality of Service for up to 4 transparent voice channels and FAX calls over any IP or PSTN network, the 2292/2294 leverages low-cost IP services with packet-voice for complete branch office voice and data connectivity.

Figure 5. Leased-line extension application
Typical application 20


Model 2292 & 2294 Series Getting Started Guide 3 • Hardware installation
Before you start the actual installation, it is strongly recommended that you gather all the information needed to install and setup the device. See table 3 for an example of what pre-installment checks you might need to carry out. Having carried out the pre-installation checks enables you to install and set up your SmartNode extender into an existing infrastructure with confidence.
The mains outlet that is utilized to power the equipment must be within 1 foot (0.3048 meters) of the device and shall be easily accessible.
Before installing the SmartNode extender device, the following tasks should be completed:
When you finish preparing for SmartNode extender installation, go to section “Installing the SmartNode extender” on page 25 to install the device.
Planning the installation 22

Model 2292 & 2294 Series Getting Started Guide 3 • Hardware installation
Installation checklist The installation checklist (see table 3) lists the tasks for installing a SmartNode 2292 or 2294 Series extender. Make a copy of this checklist and mark the entries as you complete each task. For each SmartNode 2292 or 2294 Series extender, include a copy of the completed checklist in your site log.
Table 3. Installation checklist
Task Verified by Date
Network information available & recorded in site log
Site power voltages verified
Installation site pre-power check completed
All printed documents available
SmartWare release & build number verified
Rack, desktop, or wall mounting of chassis completed
Initial electrical connections established
ASCII terminal attached to console port
Cable length limits verified
Planning the installation 23

Model 2292 & 2294 Series Getting Started Guide 3 • Hardware installation
Site log Patton recommends that you maintain a site log to record all actions relevant to the system, if you do not already keep such a log. Site log entries should include information such as listed in table 4.
Table 4. Sample site log entries
Installation Make a copy of the installation checklist and insert it into the site log
Upgrades and maintenance Use the site log to record ongoing maintenance and expansion history
Configuration changes Record all changes and the reasons for them
Maintenance Schedules, requirements, and procedures performed
Comments Notes, and problems
Software Changes and updates to SmartWare software
Network information Network connection considerations that you should take into account for planning are provided for several types of network interfaces are described in the following sections.
Network Diagram Draw a network overview diagram that displays all neighboring IP nodes, connected elements and telephony components.
IP related information Before you can set up the basic IP connectivity for your SmartNode 2292 or 2294, you should have the fol- lowing information:
Software tools You will need a PC (or equivalent) with a VT-100 emulation program (e.g. HyperTerminal) to configure the software on your SmartNode extender.
Power source If you suspect that your AC power is not reliable, for example if room lights flicker often or there is machinery with large motors nearby, have a qualified professional test the power. Install a power conditioner if necessary.
Planning the installation 24
Entry Description

Model 2292 & 2294 Series Getting Started Guide 3 • Hardware installation
Location and mounting requirements The SmartNode extender is intended to be placed on a desktop or similar sturdy, flat surface that offers easy access to the cables. Allow sufficient space at the rear of the chassis for cable connections. Additionally, you should consider the need to access the unit for future upgrades and maintenance.
When you finish installing the SmartNode, go to chapter 4, “Getting started with the SmartNode” on page 32.
Mounting the SmartNode extender Place the extender on a desktop or similar sturdy, flat surface that offers easy access to the cables. The extender should be installed in a dry environment with sufficient space to allow air circulation for cooling.
Do not work on the system or connect or disconnect cables during periods of lightning activity.
The Interconnecting cables shall be acceptable for external use and shall be rated for the proper application with respect to voltage, current, anticipated temperature, flammability, and mechanical serviceability.
Installing extender cables takes place in the following order:
Installing the SmartNode extender 25

Model 2292 & 2294 Series Getting Started Guide 3 • Hardware installation
Installing an interface cable on the extender’s voice ports The SmartNode extender comes with at least two voice ports (see figure 6) located on the back of the extender. The voice ports are connected to analog devices via cables (see figure 7) terminated with RJ-11 connectors (see figure 9 and table 5 on page 27 for pin-out information).

Figure 6. Rear view showing location of Ethernet connectors and voice ports (SmartNode 2294 shown)
Figure 7. Analog connection
Installing the SmartNode extender 26


Model 2292 & 2294 Series Getting Started Guide 3 • Hardware installation
Figure 8. Analog connection

Figure 9. RJ-11 pinout diagram
Table 5. RJ-11 socket
3 Ring (-) 4 Tip (+)
Installing the SmartNode extender 27
Pin Signal

Model 2292 & 2294 Series Getting Started Guide 3 • Hardware installation
Installing the Ethernet cable The SmartNode 2292 Series has automatic MDX (auto-cross-over) detection and configuration on the Ether- net ports. Any of the two ports can be connected to a host or hub/switch with a straight-through wired cable (see figure 10 on page 28). Ethernet devices (10Base-T or 100Base-T) are connected to the SmartNode’s Ether- net ports (see table 6 for port pin-out listing) via a cable terminated with RJ-45 plugs. Because the SmartNode 2294 Series does not have the MDX feature, a cross-over cable is required when connecting SmartNode 2294 Series devices to a host (see figure 11 on page 29).
Table 6. Ethernet 10/100Base-T (RJ-45) port pin-outs (SmartNode 2294 Series)

Figure 10. Connecting a SmartNode 2294 Series device to a hub
Installing the SmartNode extender 28
Pin Signal

Model 2292 & 2294 Series Getting Started Guide 3 • Hardware installation

Figure 11. Connecting to a host
Installing the SmartNode extender 29

Model 2292 & 2294 Series Getting Started Guide 3 • Hardware installation
Connecting to external power source The extender comes with an external power supply. This section describes installing the power cord into the extender. Do the following:

External power supply connector (accepts 12 VDC, 1.25 A, from external AC adapter)
Figure 12. Power connector location on rear panel

The extender power supply automatically adjusts to accept an input voltage from 100 to 240 VAC (50/60 Hz).
Verify that the proper voltage is present before plugging the power cord into the receptacle. Failure to do so could result in equipment damage.
Installing the SmartNode extender 30

Model 2292 & 2294 Series Getting Started Guide 3 • Hardware installation

Figure 13. SmartNode extender front panel LEDs and Console port locations (SmartNode 2294 shown)
Congratulations, you have finished installing the SmartNode extender! Now go to chapter 4, “Getting started with the SmartNode” on page 32.
Installing the SmartNode extender 31


Model 2292 & 2294 Series Getting Started Guide 4 • Getting started with the SmartNode
This chapter leads you through the basic steps to set up a new SmartNode and to download a configuration.
Patton SmartNodes can be used for a wide variety of IP-based network applications. To support and ease the configuration of the SmartNodes configuration, templates for the most important applications are available on the Patton server at www.patton.com/voip
The main steps for setting up a new SmartNode are shown in figure 14.

Ethernet interface ETH0 PC or workstation or VT-100 emulation terminal
SmartNode. You do not have to load a configuration file.
Figure 14. Steps for setting up a new SmartNode
Introduction 33

Model 2292 & 2294 Series Getting Started Guide 4 • Getting started with the SmartNode
Power connection and default configuration First the SmartNode must be connected to the mains power supply with the power cable. Wait until the 'Run' LED stops blinking and lights constantly. Now the SmartNode is ready.
The factory default configuration for the Ethernet interface IP addresses and network masks are listed in table 7.
Table 7. Factory default IP address and network mask configuration

Interface Ethernet 0 (ETH0) DHCP DHCP Interface Ethernet 1 (ETH1) 192.168.1.1 255.255.255.0
Both Ethernet interfaces are activated upon power-up.
Connect with the serial interface The Console port is wired as an EIA-561, RS-232 port. Use the included Model 16F-561 adapter and cable (see figure 15) between the SmartNode’s Console port and a PC or workstation’s RS-232 serial interface. Activate the terminal emulation program on the PC or workstation that supports the serial interface (e.g. HyperTerm).

Figure 15. Connecting to the terminal
Configure the IP address 34

Model 2292 & 2294 Series Getting Started Guide 4 • Getting started with the SmartNode
Login 1. Accessing your SmartNode via the local console port (or via a Telnet session) causes the login screen to dis- play. Type the factory default login: administrator and leave the password empty. Press the Enter key after the password prompt.
login:administrator
172.16.40.1> 2. After you have successfully logged in you are in the operator execution mode, indicated by > as command line prompt. With the commands enable and configure you enter the configuration mode.
172.16.40.1>enable
172.16.40.1#configure
172.16.40.1(cfg)# 3. Enter the following commands for the first SmartNode 229x device in the pair:
Copy nvram:a-side-config startup-config
Copy running-config startup-config 4. Follow the same procedure for the other SmartNode 229x device in the pair:
Copy nvram:b-side-config startup-config
Note The configuration above is only a sample configuration that you may use as an example. You should specify your own parameters such as your IP address and other related parameters as required. For detailed information about configuring and operating your SmartNode, set-up procedures, and trouble- shooting, refer to the SmartNode Series SmartWare Software Configuration Guide on the CD-ROM that came with your unit.
The steps above will configure the IP addresses as well as the required configurations for voice connections.
Configure the IP address 35
Copy running-config startup-config

Status LEDs 37

Model 2292 & 2294 Series Getting Started Guide 5 • LEDs status and monitoring

This chapter describes SmartNode VoIP extender front panel LEDs. Figure 16 shows SmartNode 2292 and 2294 Series LEDs. LED definitions are listed in table 8 on page 37.
Figure 16. Examples of SmartNode 2292 and 2294 Series front panels
Table 8. SmartNode LED Indications
Note If an error occurs, all LEDs will flash once per second. Power When lit, indicates power is applied. Off indicates no power applied. Run When lit, indicates normal operation. Flashes once per second during boot (startup). VoIP Link When lit, indicates the gateway is registered on a gatekeeper, media gateway con- troller, associated to a remote unit, or has an active VoIP connection. Off indicates the unit is not configured or registered and has no active VoIP connection. Flashing green indicates that the unit is attempting or has failed to associate/register Voice port Solid when leased line channel is operational. Should not be off or blinking. Ethernet (each port) • Link: Lit when Ethernet link is up.
LED Description · Status LEDs 37


Model 2292 & 2294 Series Getting Started Guide 6 • Contacting Patton for assistance
This chapter contains the following information:
Patton Electronics offers a wide array of free technical services. If you have questions about any of our other products we recommend you begin your search for answers by using our technical knowledge base. Here, we have gathered together many of the more commonly asked questions and compiled them into a searchable database to help you quickly solve your problems:
Patton Electronics is an ISO-9001 certified manufacturer and our products are carefully tested before ship- ment. All of our products are backed by a comprehensive warranty program.
Warranty coverage Our products are under warranty to be free from defects, and we will, at our option, repair or replace the prod- uct should it fail within one year from the first date of shipment. Our warranty is limited to defects in work- manship or materials, and does not cover customer damage, lightning or power surge damage, abuse, or unauthorized modification.
Out-of-warranty service Patton services what we sell, no matter how you acquired it, including malfunctioning products that are no longer under warranty. Our products have a flat fee for repairs. Units damaged by lightning or other catastro- phes may require replacement.
Returns for credit Customer satisfaction is important to us, therefore any product may be returned with authorization within 30 days from the shipment date for a full credit of the purchase price. If you have ordered the wrong equipment or you are dissatisfied in any way, please contact us to request an RMA number to accept your return. Patton is not responsible for equipment returned without a Return Authorization.
Introduction 39

Model 2292 & 2294 Series Getting Started Guide 6 • Contacting Patton for assistance
Return for credit policy • Less than 30 days: No Charge. Your credit will be issued upon receipt and inspection of the equipment.
RMA numbers RMA numbers are required for all product returns. You can obtain an RMA by doing one of the following:
All returned units must have the RMA number clearly visible on the outside of the shipping container. Please use the original packing material that the device came in or pack the unit securely to avoid damage during shipping.
Shipping instructions The RMA number should be clearly visible on the address label. Our shipping address is as follows:
Patton will ship the equipment back to you in the same manner you ship it to us. Patton will pay the return shipping costs.
Warranty Service and Returned Merchandise Authorizations (RMAs) 40


Model 2292 & 2294 Series Getting Started Guide A • Compliance information
EMC • EN55022, Class A
This equipment conforms to the requirements of Council Directive 1999/5/EC on the approximation of the laws of the member states relating to Radio and Telecommunication Terminal Equipment and the mutual rec- ognition of their conformity.
The safety advice in the documentation accompanying this product shall be obeyed. The conformity to the above directive is indicated by CE sign on the device.
The signed Declaration of Conformity can be downloaded at www.patton.com/certifications
Safety • EN60950 · Compliance 42


Model 2292 & 2294 Series Getting Started Guide B • Specifications
2 audio lines (2292)
4 audio lines (2294)
Bandwidth 4kHz, Impedance 600-ohm
Narrow Band FXS style hybrid transmit/receive
Two 10/100 Ethernet ports
Complete IP access router
DHCP Client & server
Static firewall, NAT, NAPT RFC 1631 access control lists
IPsec, IKE, AES/DES/3DES Encryption
Traffic management, shaping and policing
IEEE 802.1p, TOS, DiffServ labeling
IEEE 802.1Q, VLAN tag insertion/deletion (simultaneous support of multiple VLANs)
H.323v4, SIPv2 (B2BUA
support of multiple registrars and direct
IP dialing) • SIP call transfer, redirect
DTMF in-band & out-of-band

Model 2292 & 2294 Series Getting Started Guide B • Specifications
CODEC G.711 a-law/mu-law, G.723, G.729ab,
G.726, G.727. T.38 fax relay (9.6 k, 14.4k)
G.711 transparent fax and bypass
Web/HTTP, CLI with local console and remote Telnet access
TFTP configuration & firmware loading
SNMP MIB II and product MIB
Secure Mass provisioning for both firmware and unit configuration
Built-in diagnostic tools (trace, debug, call generator)
CPU Motorola MPC875 @66MHz
Memory 32MB SDRAM/8MB Flash
Power 100–240 VAC (50/60Hz)
Power dissipation 4-8W, model dependent
Humidity
5–80%, non-condensing · Voice Processing 45


Model 2292 & 2294 Series Getting Started Guide C • Cabling
This section provides information on the cables used to connect the SmartNode and the interface cards to the existing network infrastructure and to third party products.
The SmartNode can be connected to a serial terminal over its serial console port, as depicted in figure 17.

Figure 17. Connecting a serial terminal
Introduction 47

Model 2292 & 2294 Series Getting Started Guide C • Cabling
Ethernet devices (10Base-T/100Base-T) are connected to the SmartNode over a cable with RJ-45 plugs. Use a cross-over cable to a host, or a straight cable to a hub. See figure 18 (host) and figure 19 on page 49 (hub) for the different connections.

Figure 18. Ethernet cross-over
Ethernet 10Base-T and 100Base-T 48


Model 2292 & 2294 Series Getting Started Guide C • Cabling
Figure 19. Ethernet straight-through
Applicable to SmartNodes equipped with FXS ports. The FXS ports are connected to analog terminals (phones, fax machines, answering machines) via cables terminated with RJ-11 connectors (see section “Voice port” on page 51 for details on port pinouts).

Figure 20. Connecting an FXS device
Analog FXS 49


Model 2292 & 2294 Series Getting Started Guide D • Port pin-outs
This section provides pin-out information for the ports of the SmartNode.
Figure 21. EIA-561 (RJ-45 8-pin) port
Table 9. RJ-45 socket
The voice ports use an RJ-11 connector with 6 positions. The midle two positions 3 and 4 are used according to table 10.
Table 10. RJ-11 socket
3 Ring (-) 4 Tip (+)
Pin Signal · Pin Signal · Introduction 51

Introduction 53

Model 2292 & 2294 Series Getting Started Guide E • Installation checklist
This appendix lists the tasks for installing a SmartNode 2292 or 2294 Series extender (see table 11) . Make a copy of this checklist and mark the entries as you complete each task. For each SmartNode 2292 or 2294 Series extender, include a copy of the completed checklist in your site log.
Table 11. Installation checklist
Task Verified by Date
Network information available & recorded in site log
Site power voltages verified
Installation site pre-power check completed
All printed documents available
SmartWare release & build number verified
Rack, desktop, or wall mounting of chassis completed
Initial electrical connections established
ASCII terminal attached to console port
Cable length limits verified
Pages referenced in this manual — manufacturer, support and downloads.