Table of Contents 22 sections MODEL 1184 & MODEL 1185 Kilolight™ Single Fiber Modems · USER MANUAL · 1.3 SERVICE · 2.2 DESCRIPTION · … ShowHide
Page 1 of the Patton electronic 1184 user manual — MODEL 1184 & MODEL 1185 Kilolight™ Single Fiber Modems
Page 1 · click to enlarge
Page 1

An ISO-9001 Certified Company

Part# 07M1185-C Doc# 035011U-C Revised 08/16/99

Patton electronic 1184 — MODEL 1184 & MODEL 1185 Kilolight™ Single Fiber Modems diagram (page 1)
Fig. 1 · MODEL 1184 & MODEL 1185 Kilolight™ Single Fiber Mode…

MODEL 1184 & MODEL 1185 Kilolight™ Single Fiber Modems

USER MANUAL

SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com

Page 2 of the Patton electronic 1184 user manual — MODEL 1184 & MODEL 1185 Kilolight™ Single Fiber Modems
Page 2 · click to enlarge
Page 2
Page 2 of the Patton electronic 1184 user manual — MODEL 1184 & MODEL 1185 Kilolight™ Single Fiber Modems
Page 3 of the Patton electronic 1184 user manual — 2.0 GENERAL INFORMATION
Page 3 · click to enlarge
Page 3

Patton Electronics' technical staff is also available to answer any questions that might arise concerning the installation or use of your Model 1184 or 1185. Technical Service hours: 8AM to 5PM EST, Monday through Friday.

All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Service at (301) 975-1007, at our web site at http://www.patton.com, or at support@patton.com.

1.3 SERVICE

The Model 1184 and 1185 also incorporate V.54 compliant local and remote loopback test modes that are activated by a convenient front panel switch. LED status indicators monitor interface data and control signals as well as test mode status. Available with options for AC or DC power supply, the Models 1184 and 1185 conveniently fit in a wide range of applications and power supply environments.

Both Models 1184 and 1185 feature replaceable Patton’s DCE- DTE QuickConnect™ interface modules. Available interfaces include V.24/RS-232, V.35, RS-422/530, X.21, Ethernet Bridge and G.703. Fiber connections are made using a ST or SMA type interface.

The Patton Model 1184 and 1185 are designed for high speed RS-232 communication over a single multi-mode fiber. Operating up to 128 kbps synchronous and 19.2 kbps asynchronous data rates, Model 1184 is perfect for campus applications where data integrity is a must. And Model 1185 is even faster at a bursty 256 kbps synchronous or 38.4 kbps async.! Synchronous clocking options include internal, external, or receive recovered clock.

2.2 DESCRIPTION

2.1 FEATURES

Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to contact Patton Electronics Technical Support at (301) 975-1007;

  • Model 1184: Synchronous data rates: 4.8 - 128 kbps Asynchronous data rates: 0-19.2 kbps
  • Model 1185 : Synchronous data rates: 2.4 - 256 kbps Asynchronous data rates: 0 - 38.4 kbps
  • Full duplex operation over a single multi-mode fiber optic cable
  • Point-to-point distances up to 3 miles
  • Internal, external or receive recovered clocking options
  • Field Replaceable DTE-DCE QuickConnect™ interface modules: V.24/RS-232, V.35, RS-422/530, X.21 and G.703
  • V.54 compliant local and Remote Digital Loopback tests
  • 8 Front Panel LED Status Indicators
  • Available with ST or SMA Fiber Connectors
  • Made in the U.S.A.

2.0 GENERAL INFORMATION

Page 4 of the Patton electronic 1184 user manual — 1184 AND 1185 S1 SUMMARY TABLE
Page 4 · click to enlarge
Page 4
3.0 CONFIGURATION Both Models 1184 and 1185 use a mini DIP switch package that allows configuration to a wide range of applications. These switches are located on the bottom side of the PC board. Figure 1 shows the switch locations with respect to the other components on the PC board. Because all eight switches are externally accessible, there is no need to open the case to configure the unit. ON 1 2 3 4 5 6 7 8 Figure 1. Underside of Model 1184/1185, Showing Location of DIP Switches 3.1 CONFIGURATION SET “S1” The switches shown in Figure 2 below and on DIP switch S1 are used to set the async or sync data rates, LAL and DL diagnostic functions and the clock mode setting. The default settings for DIP switch S1 are shown in the table on page 6. Following the table are detailed descriptions for each switch. ON ON OFF 1 2 3 4 5 6 7 8 Figure 2. Close Up of Configuration Switches 5
1184 AND 1185 S1 SUMMARY TABLE PositionFunctionFactory Default S1-1* S1-2* S1-3* S1-4*Data Rate Data Rate Data Rate Data RateOff } Off 64 Off kbps On S1-5 S1-6Clock Source Clock SourceOn } Internal On S1-7DTE Control of DLOff Disabled S1-8DTE Control of LALOff Disabled

1 2 3 4 5 6 7 8

ON

Switch S1-1 through S1-4 (Model 1184:): Async/Sync Data Rate

*NOTE: Both Models 1184 and 1185 use Switches S1-S4 to set the async or sync data rate. Refer to the sections below to set the Model 1184 or 1185 rates.

Position Function Factory Default

S1-4* Data Rate On

S1-3* Data Rate Off

S1-2* Data Rate Off

S1-1* Data Rate Off

S1-8 DTE Control of LAL Off Disabled

S1-7 DTE Control of DL Off Disabled

S1-6 Clock Source On

S1-5 Clock Source On

1184 AND 1185 S1 SUMMARY TABLE

Internal }

}

}

Async Setting · 64 kbps · Sync Settings

Page 5 of the Patton electronic 1184 user manual — }
Page 5 · click to enlarge
Page 5

Data Max Distance S1-1 S1-2 S1-3 S1-4 Rate (kbps) in miles (km)

On Model 1185 Switches S1-1, S1-2, S1-3 and S1-4 set two parameters: synchronous or asynchronous data rate and the maximum transmission distance between two Model 1185s.

Switch S1-1 through S1-4 (Model 1185): Async/Sync Data Rate

On On On Off 2.4 1.5 (2.4) Off On On On 9.6 3.0 (4.8) On Off On Off 14.4 1.5 (2.4) On Off On On 19.2 3.0 (4.8) Off Off On Off 28.8 1.5 (2.4) Off Off On On 38.4 3.0 (4.8) On On Off On 48.0 3.0 (4.8) Off On Off Off 56.0 1.5 (2.4) Off Off Off On 64.0 3.0 (4.8) Off On On Off 72.0 1.5 (2.4) Off 128.0 1.5 (4.8) On On Off Off 144.0 1.5 (2.4) Off On Off On 192.0 1.5 (2.4) On 256.0 1.5 (2.4)

On Off Off On 0-19.2 3.0 (4.8) On Off Off Off 0-38.4 1.5 (2.4)

}

}

The setting for switch S1-8 determines whether DTE control of local analog loopback test is enabled or disabled. If DTE control is disabled, the LAL test can only be initiated by the front panel switch. If DTE control is not available, set switch S1-8 to the Off position.

Switch S1-8DTE Control of LAL

The setting for Switch S1-7 determines whether DTE control of remote digital loopback test is enabled or disabled. If DTE control is disabled, the DL test can only be initiated by the front panel switch. If DTE control is not available, set switch S1-7 to the Off position.

Switch S1-7DTE Control of DL

Switches S1-5 and S1-6 are set in combination to determine Model 1184 and 1185 transmit clock source.

Switches S1-5 and S1-6Clock Source

S1-7 Setting Description On Enabled Respond to LAL requests from DTE Off Disabled Ignore LAL requests from the DTE

S1-7 Setting Description On Enabled Respond to DL requests from DTE Off Disabled Ignore DL requests from the DTE

Off Off Received Recover Transmit clock derived from the received line signal

Off On External Transmit clock derived from terminal interface

On On Internal Transmit clock generated internally

S1-5 S1-6 Setting Description On Off Internal Transmit clock generated internally

Async Settings · Sync Settings

Page 6 of the Patton electronic 1184 user manual — 4.2 CONNECTION TO THE SERIAL PORT
Page 6 · click to enlarge
Page 6
Patton electronic 1184 — 4.1 CONNECTION TO THE FIBER INTERFACE diagram (page 6)
Fig. 2
Patton electronic 1184 — 4.1 CONNECTION TO THE FIBER INTERFACE diagram (page 6)
Fig. 3

These short range modems are designed to work in pairs. You will need one at each end of single 50 or 62.5 micron multi-mode fiber cable. The fiber cable connects to each Model 1184 or 1185 using either an ST or an SMA connector. Figure 4 below shows a close-up of both connector types.

The Model 1184 supports communication between two terminal equipment at distances to 3 miles (4.8km) and data rates to 128 kbps (sync) or 19.4 kbps (async). Model 1185 also supports distances up to 3 miles (4.8km), but at rates up to 256 kbps (sync) or 38.4 (async). Figure 3 shows the position of the interface connectors on the Model 1184 or 1185 back panel.

4.1 CONNECTION TO THE FIBER INTERFACE

Once the Model 1184 or 1185 is properly configured, it is ready to connect to the fiber interface, to the serial port, and to the power source. This section tells you how to make these connections.

Figure 3. Rear Panel of Model 1184/1185, Showing Interface and Power Connectors

Figure 4. Close-up of ST and SMA Connectors

4.0 INSTALLATION

Patton electronic 1184 — 4.0 INSTALLATION diagram (page 6)
Fig. 4

Removing the Existing QuickConnect™ Module

When you purchase a particular version of the Model 1184 or 1185, it should be shipped to you with the appropriate QuickConnect™ Module already installed. If you need to install a different QuickConnect™ Module, follow these steps:

4.2.1 Changing QuickConnect™ Modules

The serial port interface on the Model 1184 and 1185 uses interchangeable QuickConnect™ Modules. Each QuickConnect™ Module has a 50-pin card edge connector on one side and a serial port interface on the other. Figure 2 below shows how a QuickConnect™ Module plugs into the back of the Model 1184/1185.

4.2 CONNECTION TO THE SERIAL PORT

3. Grasp the two thumbscrews and gently pull the module from the unit. Apply equal force to the thumbscrews to keep the module straight during the removal process.
2. Loosen the two thumbscrews on the module by turning them counterclockwise.
1. Turn the power switch off. Leave the power cord plugged into a grounded outlet to keep the unit grounded.

Figure 5. Installation of Model 1184/1185 Plug-in Serial Interface Module

Line · Interface Port

Page 7 of the Patton electronic 1184 user manual — 4.3 POWER CONNECTION
Page 7 · click to enlarge
Page 7

The serial port on most QuickConnect™ interface modules is hard- wired as a DCE (all except the X.21 module). Therefore you must use a null modem cable when connecting to a modem, multiplexer or other DCE device. This cable should be of the shortest possible length—we recommend 6 feet or less. When purchasing or constructing a null modem interface cable, use the pin diagrams in Appendix D as a guide.

4.2.3 Connection to a “DCE” Device

The serial port on most QuickConnect™ interface modules (all except the X.21 module) are hard-wired as DCE. Therefore these modules “want” to plug into a DTE such as a terminal, PC or host. When making the connection to your DTE device, use a straight through cable of the shortest possible length—we recommend 6 feet or less. When purchasing or constructing an interface cable, please refer to the pin diagrams in Appendix D as a guide.

4.2.2 Connection to a “DTE” Device

Installing the New QuickConnect™ Module

5. To secure the module in place, push the thumbscrews into the chassis and turn the screws clockwise to tighten.
4. With the card edge contacts aligned with the socket, firmly seat the module by using your thumbs to apply pressure directly to the right and left edges of the module faceplate. Applying moderate and even pressure should be sufficient to seat the module. You should hear it “click” into place.
3. While keeping the module’s faceplate parallel with the Model 1184/1185 rear panel, slide the module straight in–so that the card edge contacts line up with the socket inside the chassis.
2. Hold the module with the faceplate toward you and align the module with the guide slots in the rear panel of the Model 1184/1185.
1. Make sure the power switch is off. Leave the power cord plugged into a grounded outlet to keep the unit grounded.

The two AC power supply options–Standard and Universal–are equipped with a male IEC-320 power connection. A domestic (US) power supply cord is supplied with the unit at no extra charge. To connect the standard or universal power supply, follow these steps:

4.3.1 Connecting to an AC Power Source

DC Power Supply option (Model 1184/1185-DC) operates in 48 VDC environments and is equipped with a 3-pin “terminal strip” style connector.

Universal Interface AC Power Supply option (Model 1184/1185- UI) operates in environments ranging from 85 to 256 VAC, with no re- configuration necessary (see Appendix C for available domestic and international power cords).

4.3 POWER CONNECTION

To reverse DCE/DTE orientation, remove the module according to the instructions in Section 4.2.1. The DCE/DTE strap is located on the bottom side of the module’s PC board. The arrows on the top of the strap indicate the configuration of the X.21 port (for example, if the DCE arrows are pointing toward the DB-15 connector, the X.21 port is wired as a DCE). Reverse the DCE/DTE orientation by pulling the strap out of its socket, rotating it 180º, then plugging the strap back into the socket. You will see that the DCE/DTE arrows now point in the opposite directions, showing the new configuration of the X.21 port. Reinstall the module according to the instructions in Section 4.2.1.

The serial port on the X.21 QuickConnect™ Module is default wired as a DCE, but may be switched to a DTE. This is done by reversing the orientation of the DCE/DTE strap, as described below:

4.2.4 Re-configuring the X.21 QuickConnect™ Module

Standard AC Power Supply option (Model 1184/1185, or 1184/1185-230) is switchable between 100 and 253 VAC and is available with a variety of domestic and international power cords. (See Appendix C).

3. Turn the rear power switch ON.
2. Plug the power cord into a nearby AC power outlet.
1. Attach the power cord (supplied) to the shrouded male IEC-320 connector on the rear of the Model 1184 or 1185.

The Model 1184/1185 is available with three power supply options:

Page 8 of the Patton electronic 1184 user manual — 5.0 OPERATION
Page 8 · click to enlarge
Page 8

The 48 VDC power supply option uses a 3-pin terminal block with spring-type connectors. Please refer to the Model 1090 Series Service Manual.

4.3.2 Connecting to a DC Power Source

The Model 1184 and 1185 feature eight front panel LEDs that monitor power, the DTE signals, network connection and test modes. Figure 6 (below) shows the front panel location of each LED. Following Figure 6 is a description of each LEDs function.

5.2 LED STATUS MONITORS

To apply power to the Model 1184/1185, first be sure that you have read Section 4.3, and that the unit is connected to the appropriate power source. Then power-up the unit using the rear power switch.

5.1 POWER-UP

Once the 1184 or 1185 is properly configured and installed, it should operate transparently. This sections describes power-up, reading the LED status monitors, and using the built-in loopback tests.

NS Glows red to indicate that the local Model 1184/1185 has not yet connected with the remote 1184/1185.

TM Glows red to indicate that the Model 1185 has been placed in Test Mode. The unit can be placed in test mode by the local or remote user. For RDL, the TM LED will only glow red on the local unit.

ER Glows red to indicate the likelihood of a Bit Error in the received signal.

DTR Glows green to indicate that the Data Terminal Ready signal from the terminal is active.

CD Glows red if no carrier signal is being received from the remote modem. Green indicates that the remote modem’s carrier is being received.

RTS Glows green to indicate that the Request to Send signal from the DTE is active.

TD & RD Glows red to indicate an idle condition of Binary “1” data on the respective terminal interface signals. Green indicates Binary “0” data.

RD TD RTS CD DTR ER NS TM TEST MODES

Figure 6. Model 1185 Front Panel

5.0 OPERATION

Model 1185 High Speed Single Fiber Modem

- Remote - Normal - Local

Page 9 of the Patton electronic 1184 user manual — 5.3 DIAGNOSTICS
Page 9 · click to enlarge
Page 9

To perform a Local Analog Loopback test, follow these steps.

The Local Analog Loopback (LAL) test checks the operation of the local Model 1184 or 1185 and is performed separately on each unit. Any data sent to the local Model 1184/1185 in this test mode will be echoed (returned) back to the user device. (See Figure 7, below). For example, characters typed on the keyboard of a terminal will appear on the terminal screen.

5.3.1 Local Analog Loopback

Model 1184 and 1185 are equipped with V.54 diagnostics that may be used to to evaluate the condition of the local and remote units, as well as the twisted pair link between them: local loopback (LAL) and remote digital loopback (DL).

5.3 DIAGNOSTICS

3. Perform a BER (bit error rate) test on each unit using a separate BER tester. If the BER test equipment indicates no faults but the data terminal indicates a fault, follow the manufacturer's checkout procedures for the data terminal. Also, check the interface cable between the terminal and the Model 1184/1185.
2. Verify that the data terminal equipment is operating properly and can be used for a test. If a fault is indicated, call a technician or replace the unit.
1. Activate LAL either by moving the front panel toggle switch DOWN to “Local”, or; by raising the appropriate signal on the DTE interface. Once Local Analog Loopback is activated, the Model 1184/1185’s transmit output is connected to its own receiver. The test LED should glow.

Figure 7. Local Analog Loopback

To perform an DL test, follow these steps:

The Remote Digital Loopback test checks the performance of both the local and remote Model 1184/1185, and the communication link between them. Any characters sent to the remote unit in this test mode will be returned back to the originating device (see Figure 7).

5.3.2 Remote Digital Loopback

3. If the BER test equipment indicates a fault and the Local Analog Loopback test was successful for both Model 1184 or 1185s, you may have a problem with the line between the units. You should inspect the line for proper connections.
2. Perform a BER (bit error rate) test on the system, using BER testers on both ends.
1. Activate DL. This may be done in one of two ways: First, by moving the front panel toggle switch DOWN to “Remote”. Or, second, by raising the DL signal on the terminal interface (for pin numbers, see Appendix D).

Figure 7. Remote Digital Loop

Local Model 1184/1185

Page 10 of the Patton electronic 1184 user manual — FACTORY REPLACEMENT PARTS AND ACCESSORIES
Page 10 · click to enlarge
Page 10

Transmission: Asynchronous and Synchronous Clocking: Internal, external or derived from receive signal Distance: 3 miles maximum (4.8km) 1184 Data Rates: Asynchronous: 0 to 19.2 kbps Synchronous: 4.8, 9.6, 14.4, 19.2, 28.8, 32.0, 56.0, 64.0, 128.0 kbps 1185 Data Rates: Asynchronous: 2.4 to 38.4 kbps Synchronous: 2.4, 9.6, 14.4, 28.8, 38.4, 56.0, 64.0, 72.0, 128.0, 144.0, 192.0, 256.0 kbps Handshaking: Software (XON/XOFF) or hardware (RTS/CTS). Both modes available at all times. Connectors: Either ST or SMA Link Budget: 12 dB (62.5 micron), 8 dB (50.0 micron) Diagnostics: V.54 Compliant - Local Analog Loopback and Remote Digital Loopback bit error rate pattern Fiber Modes: Single 50 or 62.5 micron core, multi-mode fiber optic cable LED Indicators TD, RD, RTS, DTR, ER, NS and TM Interface Modules: EIA RS-232/CCITT V.24, RS-232/530, CCITT V.35, X.21, Ethernet Bridge and G.703 Power: 115/230 VAC (switch selectable), 50/60 Hz, 5 Watts; 85V - 256 VAC, 50/60 Hz (universal input option); 48 VDC (option). 5 Watts. Regulatory FCC part 15 Class A Compliance: UL 1950, EN60950 89/336/EEC, 73/23/EEC IEC 825 Class 1 equipment Temperature Range: 0-50°C (32-122°F) Altitude: 0-15,000 feet Humidity: 5 to 95% non-condensing Dimensions: 7.3” x 6.6” x 1.62” ( mm x mm x mm) Weight: 2.02 lbs. 1.0 Kg

SPECIFICATIONS

APPENDIX A

Patton Model # Description

IM1/A V.24 with DB25F IM1/B RS422/RS530 with DB25F IM1/C V.35 with M34F IM1/D X.21 with DB15F IM1/E V.35 with DB25F IM1/F G.703 with RJ45 IM1/G High Speed Async w/DB-25F IM1/I Ethernet Bridge 0805US American Power Cord 0805EUR European Power Cord CEE 7 0805UK United Kingdom Power Cord 0805AUS Australia/New Zealand Power Cord 0805DEN Denmark Power Cord 0805FR France/Belgium Power Cord 0805IN India Power Cord 0805IS Israel Power Cord 0805JAP Japan Power Cord 0805SW Switzerland Power Cord 07M1090SVC Service Manual

FACTORY REPLACEMENT PARTS AND ACCESSORIES

APPENDIX B

Page 11 of the Patton electronic 1184 user manual — APPENDIX C
Page 11 · click to enlarge
Page 11

B SGND (Signal Ground) C RTS (Request to Send) D CTS (Clear to Send) E DSR (Data Set Ready) F CD (Carrier Detect) H DTR (Data Transfer Ready) L LLB (Local Line Loop) M TM (Test Mode) N DL (Remote Digital Loop) P TD(Transmit Data) R RD (Receive Data) S TD/ (Transmit Data-B) T RD/ (Receive Data-B) U XTC (External Transmit Clock) V RC(Receive Timing) W XTC/ (External Transmit Clock) X RC/ (Receive Timing) Y TC(Test Control-A) AA TC/ (Test Control-B)

V.35 Interface Pin Description M/34 Female Connector

APPENDIX C

RS-232, RS-530 and V.35 Interface Pin Description (DB-25 Female Connector)

1 FG (Frame Ground) 2 TD (Transmit Data) 3 RD (Receive Data) 4 RTS (Request to Send) 5 CTS (Clear to Send) 6 DSR (Data Set Ready) 7 SGND (Signal Ground) 8 CD (Carrier Detect) 9 RC/ (Receive Timing-B) 10 CD/ (Carrier Detect-B) 11 XTC/ (External Transmit Clock) 12 TC/ (Test Control-B) 13 CTS/ (Clear to Send) 14 TD/ (Transmit Data-B) 15 TC (Test Control-A) 16 RD (Receive Data) 17 RC (Receive Timing) 18 LLB (Local Line Loop) 19 RTS/ (Request to Send) 20 DTR (Data Transfer Rate) 21 DL (Remote Digital Loop) 22 DSR/ (Data Set Ready) 23 DTR/ (Data Transfer Rate) 24 XTC (External Transmit Clock) 25 TM (Test Mode)

Pin # Signal · Pin # Signal · APPENDIX C (cont)

Page 12 of the Patton electronic 1184 user manual — APPENDIX C
Page 12 · click to enlarge
Page 12

1 Frame Ground 2 T (Transmit Data-A) 3 C (Control-A) 4 R (Receive Data-A) 5 I (Indication-A) 6 S (Signal Element Timing-A) 7 BT (Byte Timing-A) 8 SGND (Signal Ground) 9 T/ (Transmit Data-B) 10 C/ (Control-B) 11 R/ (Receive Data-B) 12 I/ (Indication-B) 13 S/ (Signal Element Timing-B) 14 BT/ (Byte Timing-B)

X.21 Interface Pin Description (DB-15 Female Connector)

1 RD+ (Receive Data Tip) 2 RD- (Receive Data Ring) 3 Not Used 4 TD- (Transmit Data Ring) 5 TD+ (Transmit Data Tip) 6 Not Used 7 Not Used 8 Not Used

G.703 Interface Pin Assignment (RJ45 8-Pin Modular)

Show 4 more labels / short text on this page
Pin # Signal · APPENDIX C (cont) · Pin # Signal · APPENDIX C (cont)
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Local Model 1184/1185 p.9
Figure 7. Local Analog Loopback To perform a Local Analog Loopback test, follow these steps. 1. Activate LAL either by moving the front panel toggle switch DOWN to “Local”, or; by raising the appropriate signal on the DTE interface. Once Local Analog Loopback is activated, the Model 1184/1185’s transmit output is connected to its own receiver. The test LED should glow. NOTE: Although the local Model 1184/1185 cannot communicate with the remote Model 1185/1185 in this mode, the synchronized connection between the two modems remains intact. 2. Verify that the data terminal equipment is operating properly and can be used for a test. If a fault is indicated, call a technician or replace the unit. 3. Perform a BER (bit error rate) test on each unit using a separate BER tester. If the BER test equipment indicates no faults but the data terminal indicates a fault, follow the manufacturer's checkout procedures for the data terminal. Also, check the interface cable between the terminal and the Model 1184/1185. p.9
Figure 7. Local Analog Loopback To perform a Local Analog Loopback test, follow these steps. 1. Activate LAL either by moving the front panel toggle switch DOWN to “Local”, or; by raising the appropriate signal on the DTE interface. Once Local Analog Loopback is activated, the Model 1184/1185’s transmit output is connected to its own receiver. The test LED should glow. NOTE: Although the local Model 1184/1185 cannot communicate with the remote Model 1185/1185 in this mode, the synchronized connection between the two modems remains intact. 2. Verify that the data terminal equipment is operating properly and can be used for a test. If a fault is indicated, call a technician or replace the unit. 3. Perform a BER (bit error rate) test on each unit using a separate BER tester. If the BER test equipment indicates no faults but the data terminal indicates a fault, follow the manufacturer's checkout procedures for the data terminal. Also, check the interface cable between the terminal and the Model 1184/1185. p.9

Ask about the Patton electronic 1184

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Patton electronic 1184

Be the first to ask — other owners or our team will answer.