Part# 07M1094-C Doc# 032031UC R evised 04/13/99
USER MANUAL MODEL 1094 KiloModem-768
SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com

The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). A Certificate of Compliance is available by contacting Technical Support.
The Model 1094 generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and tele- vision reception. The Model 1094 has been tested and found to com- ply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interfer- ence will not occur in a particular installation. If the Model 1094 does cause interference to radio or television reception, which can be deter- mined by removing power from the unit, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).
Patton Electronics warrants all Model 1094 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modifi- cation. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequen- tial damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.
Patton Electronics’ technical staff is also available to answer any questions that might arise concerning the installation or use of your Model 1094. Technical Support hours: 8AM to 5PM EST, Monday through Friday.
All warranty and non-warranty repairs must be returned freight pre- paid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping contain- er. This number may be obtained from Patton Electronics Technical Service at:

The Model 1094 features replaceable DCE-DTE QuickConnect™ interface modules. Several different modules are available (call Patton Sales for details). Line connection is made by RJ-45 jack. Internal AC power supply options include 120 or 230VAC (switchable), 85-256VAC (universal) or 48VDC.
The Patton Model 1094 Synchronous Short Range Modem is designed for point-to-point, high speed communication over 4-wires (two twisted pair). Supporting switch-selectable data rates of 384 and 768 kbps, the Model 1094 is perfect for connecting two bridge/routers, or for similar campus applications at distances up to 4.9 miles (7.9 km). The Model 1094 incorporates built-in V.54 loopback tests, a V.52 BERT pattern generator and seven front panel LED indicators. Data integrity is enhanced by automatic equalization and gain control. The Model 1094 also incorporates transformer isolation and surge protection to guard data and connected equipment against the hazards of ground loops and transient surges. Clocking options include internal, external and receive recover clock.
2.1 FEATURES
Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warrant- ed for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to con- tact Patton Electronics Technical Support at (301) 975-1007.
The Model 1094’s DIP switches are located on the underside of the unit (see Figure 1, below). Figure 2 shows the orientation of the switch set. All possible settings for the Model 1094’s DIP switches are presented in the summary table and descriptions on the following pages.
The Model 1094 is equipped with one set of eight DIP switches, and one set of four DIP switches (all externally accessible). These DIP switches allow configuration of clock source, carrier control, loopback tests and data rate. This section describes switch locations and explains all possible configurations.
Figure 1. Underside of Model 1094 Showing External DIP Switch Locations
Figure 2. Close Up of Configuration Switches
1 2 3 4 5 6 7 8
3.0 CONFIGURATION
S1 S2
S1 S2
FRONT
1 2 3 4 5 6 7 8
ON
1 2 3 4
1 2 3 4
OFF
front panel activated)

3.1.1 Switch Set S1
Position Function Factory Default
S1-8 V.54 Enable/Disable Off Enabled
S1-7 DTE Control of LAL Off Disabled
S1-6 DTE Control of RDL Off Disabled
S1-5 Carrier Control Off Constant
S1-4 LDL Off Disabled
S1-3 RTS/CTS Delay On Short Delay
S1-2 Clock Source* On
S1-1 Clock Source* On
*See Note in SWITCH SET S1 (Below) for X.21 Clock Sources
} Internal
The setting for switch S1-7 determines whether DTE control of local analog loopback test is enabled or disabled. If DTE control is dis- abled, the LAL test can only be initiated by the front panel switch.
The setting for switch S1-6 determines whether DTE control of remote-digital loopback test is enabled or disabled. If DTE control is disabled, the RDL test can only be initiated by the front panel switch.
The setting for switch S1-5 determines whether the carrier is “con- stantly on” or “controlled by RTS”. This setting allows for operation in switched carrier or hardware handshaking applications.
Switch S1-4 determines whether the frontt panel switch can acti- vate a Local Digital Loopback (LDL) diagnostic test.
Switch S1-3 is used in combination to determine the amount of delay between the time RTS is activated and the 1094 activates the CTS.
S1-7 Setting On DTE control enabled Off DTE control disabled
S1-6 Setting On DTE control enabled Off DTE control disabled
S1-5 Setting On Controlled by RTS Off Constantly ON
S1-4 Function On LDL Control Enabled Off LDL Control Disabled
S1-3 Function On Short delay (1-4 ms) Off Long delay (8-20 ms)

The settings for DIP switches S2-1 through S2-4 determine the synchronous data rate of the Model 1094. All possible settings (includ- ing the default) are shown below:
3.1.2 Switch Set S2
The setting for switch S1-8 determines whether the Model 1094 will respond when it receives the V.54 sequence. If you suspect the Model 1094 may be getting tricked into the loopback test by false detection of user data, you can try setting this to “Disable.”
S2-1 S2-2 S2-3 S2-4 Setting Off On On On 384 kbps On Off Off Off 768 kbps (default)
S1-8 Setting On Disabled Off Enabled
*Connection to ground is optional
The Model 1094 uses a modular RJ-45 jack for twisted pair line connection. The signal/pin relationships are shown below:
The Model 1094 supports communication between two terminal devices at distances to 4.9 miles (7.9 km) and data rates to 768 kbps. There are two essential requirements for installing the Model 1094:
Once the Model 1094 is properly configured, it is ready to connect to the twisted pair interface, to the serial port, and to the power source. This section tells you how to make these connections.
1 XMT+ 2 XMT- 3 N/C 4 GND* 5 GND* 6 N/C 7 RCV+ 8 RCV-
4.0 INSTALLATION
1 2 3 4 5 6 7 8

The serial port interface on the Model 1094 uses interchangeable Quick Connect Modules. Each Quick Connect Module has a 50-pin card edge connector on one side and a serial port interface on the other. Figure 3 (below) shows how a Quick Connect™ Module plugs into the back of the Model 1094.
*Connection to ground is optional
When connecting two Model 1094’s, it is necessary to use a crossover cable. The diagram below shows how a crossover cable should be constructed.
Figure 3. Installation of Model 1094 Plug-in Serial Interface Module
XMT+ 1 8 RCV- XMT- 2 7 RCV+ GND* 4 5 GND* GND* 5 4 GND* RCV+ 7 2 XMT- RCV- 8 1 XMT+
0 OFF
1 ON
When you purchase a particular version of the Model 1094, it should be shipped to you with the appropriate QuickConnect™ Module already installed. If you need to install a different QuickConnect™ Module, follow these steps.
Removing the Existing QuickConnect™ Module
Installing the New QuickConnect™ Module
RJ-45 Cable (4-Wire) · Line · Interface Port

To reverse DCE/DTE orientation, remove the module according to the instructions in Section 4.2.1. The DCE/DTE strap is located on the bottom side of the module’s PC board. The arrows on the top of the strap indicate the configuration of the X.21 port (for example, if the DCE arrows are pointing toward the DB-15 connector, the X.21 port is wired as a DCE). Reverse the DCE/DTE orientation by pulling the strap out of its socket, rotating it 180º, then plugging the strap back into the socket. You will see that the DCE/DTE arrows now point in the opposite directions, showing the new configuration of the X.21 port. Reinstall the module according to the instructions in Section 4.2.1.
The serial port on the X.21 QuickConnect™ Module is default wired as a DCE, but may be switched to a DTE. This is done by reversing the orientation of the DCE/DTE strap, as described below:
If the Model 1094’s QuickConnect™ interface module is hard- wired as a DCE (all except the X.21 module), you must use a null modem cable when connecting to a printer, modem, multiplexer or other DCE device. This cable should be of the shortest possible length—we recommend 6 feet or less. When purchasing or construct- ing a null modem interface cable, use the pin diagrams in Appendix D as a guide.
The serial port on most QuickConnect™ interface modules (all except the X.21 module) is hard-wired as a DCE. Therefore these modules “want” to plug into a DTE such as a terminal, PC or host. When making the connection to your DTE device, use a straight through cable of the shortest possible length—we recommend 6 feet or less. When purchasing or constructing an interface cable, please refer to the pin diagrams in Appendix D as a guide.
The two AC power supply options–Standard and Universal–are equipped with a male IEC-320 power connection. A domestic (US) power supply cord is supplied with the unit at no extra charge. To con- nect the standard or universal power supply, follow these steps:
The DC power supply option (Model 1094-DC) operates in 48 VDC environments and is equipped with a 3-pin terminal block with spring-type contacts (please refer to the Model 1094 Service Manual for wiring instructions).
The Universal Interface power supply option (Model 1094-UI) operates in environments ranging from 85 to 265 VAC, with no re-con- figuration necessary (see Appendix C for available domestic and inter- national power cords).
The Standard power supply option (Model 1094 or 1094-230) is factory configured for either 115 or 230 VAC, depending on how the product is ordered, and is available with a variety of domestic and inter- national power cords (see Appendix C).
The Model 1094 is available with three power supply options:

The Model 1094 features seven front panel LEDs that monitor transmit data, receive data, request to send, carrier detect, data termi- nal ready, test modes and error conditions. Figure 4 (below) shows the front panel location of each LED. Following Figure 6 is a description of each LED’s function.
Before applying power to the Model 1094, first be sure that you have read Section 4.3, and that the your power source matches the power rating shown on the bottom label of the Model 1094. Failure to do so could result in damage to the unit and connected equipment, and may constitute a fire hazard. If your Model 1094 is AC powered, plug the AC power cord into both the Model 1094 and the AC outlet. Then power-up the unit using the rear power switch. If your Model 1094 is DC powered, and has been connected to the DC power source according to the instructions in Section 4.3, turn on the DC power supply and then power-up the unit using the rear power switch.
Once the Model 1094 is properly configured and installed, it should operate transparently. This sections describes power-up, read- ing the LED status monitors, and using the built-in loopback test modes.
TD and RD Will glow red to indicate an idle condition of Binary 1 data on the respective terminal interface signals. Green indicates Binary“0 data.
CD Will glow red if no carrier signal is being received from the remote modem. Green indicates that the remote modem’s carrier is being received.
RTS Will glow green to indicate that the Request to Send signal from the terminal is active.
Figure 4. Model 1094 Front Panel
Model 1090 KiloModem PS High Speed Sync. Short Range Modem
Local - Normal - Remote -
- 511E - Normal - 511
To perform an Analog Loopback test, follow these steps:
The Local Analog Loopback (LAL) test checks the operation of the local Model 1094. Any data sent to the local Model 1094 in this test mode will be echoed (returned) back to the user device. For example, characters typed on the keyboard of a terminal will appear on the ter- minal screen (see Figure 5, below).
The Model 1094 is equipped with three sets of diagnostics to eval- uate the condition of the local and remote units, as well as the twisted pair link between them: local analog loopback (LAL) and remote digital loopback (RDL) according to the CCITT V.54 Standard, and bit error rate BER test according to the CCITT V.52 Standard.
A. Activate Local Analog Loopback. This may be done in one of two ways: First, by moving the front panel toggle switch UP to Local. Second, by raising signal LOCAL LOOPBACK on the terminal interface (for pin numbers, see Appendix D). Once LAL is activated, the Model 1094 transmit output is connected to its own receiver. The TM LED should be lit. (continued)
TM Will glow green to indicate that the Model 1094 has been placed in Test Mode. The unit can be placed in test mode by the local user or by the remote user.
DTR Will glow green to indicate that the Data Terminal Ready signal from the terminal is active.
ER Will glow red to indicate the likelihood of a Bit Error in the received signal. During the 511 or 511/E test, ER will flash to indicate that the Test Pattern Detector has detected a bit error.
Figure 5. Local Analog Loop
Test Modes · Local 1094

To perform an RDL test, follow these steps:
The Remote Digital Loopback (RDL) test checks the performance of both the local and remote Model 1094', and the communication link between them. Any characters sent to the remote Model 1094 in this test mode will be returned back to the originating device (see Figure 6, below).
C. If the BER test equipment indicates a fault and the Local Analog Loopback test was successful for both Model 1094s, you may have a problem with the line between the Model 1094s. You should inspect the line for proper connections.
B. Perform a BER (bit error rate) test on the system, using BER testers on both ends.
A. Activate RDL. This may be done in one of two ways: First, by moving the front panel toggle switch DOWN to “Remote”. Or, second, by raising the REMOTE LOOPBACK signal on the terminal interface (for pin numbers, see Appendix D).
C. Perform a BER (bit error rate) test on each unit using a separate BER tester. If the BER test equipment indicates no faults but the data terminal indicates a fault, follow the manufacturer's checkout procedures for the data terminal. Also, check the interface cable between the terminal and the Model 1094.
B. Verify that the data terminal equipment is operating properly and can be used for a test. If a fault is indicated, call a technician or replace the unit.
Figure 6. Remote Digital Loop
Local 1094 Remote 1094
The Local Digital Loopback (LDL) test checks the local and remote 1094s and all communication paths. In LDL, the TX/RX circuit of the local 1094 closes, thereby allowing characters sent from BOTH the local terminal and remote terminal to loop back (echo) to themselves (See Figure 7, below). To accurately perform LDL diagnostics, techni- cians must send characters (or BER diagnostics) from each end. To perform a LDL, follow the instructions below:
D. If the BER test equipment indicates a fault and the Local Analog Loopback test was successful for both Model 1094s, you may have a problem with the line between the Model 1094s. You should inspect the line for proper connections.
C. Perform a BER (bit error rate) test on the system, using BER testers on both ends.
B. Enable LDL by moving the front panel toggle switch up to “Local”, Or, by raising the signal LL on the terminal interface(for pin numbers, see Appendix D).
A. On the bottom of the unit, turn S1-4 to the ON position.
Figure 7. Local Digital Loop

The Model 1094 has a built-in test pattern generator and detector. It can be invoked at both ends of a link simultaneously or it can be used with the Local Analog or Remote Digital Loopbacks. The follow- ing example requires two operators: one to initiate and monitor the test at the local Model 1094, and one at the remote Model 1094. To use the V.52 BER test by itself, both operators should simultaneously follow these steps.
A successful 511/E test will confirm that the link is in place, and that the Model 1094 built-in 511 generator and detector are working properly.
modules. Twisted Pair Interface: 8-position modular jack (RJ-45) Power: 115/230 VAC (switch selectable), 50/60 Hz; 85 - 256 VAC, 50/60 Hz (universal input option); 48 VDC (option). 5 watts. Temperature Range: 0-50°C (32-122°F) Altitude: 0-15,000 feet Humidity: 5 to 95% non-condensing Dimensions: 7.3” x 6.6” x 1.62” (185mm x 168mm x 41mm) Weight: 2.02 lbs. 1.0 Kg
Transmission Format: Synchronous Transmission Line: Unconditioned twisted pair 19 - 26 AWG Clocking: Internal, external or receive loopback Distance: Up to 4.9 miles (7.9 km) (19 AWG @ 384 kbps) Data Rates: 384 and 768 kbps (switch selectable) Carrier Control: Constantly on or Controlled by RTS RTS/CTS Delay: No delay, short delay (1 - 4 ms), long delay (8 - 20 ms). Diagnostics: V.52 compliant bit error rate pattern (511/511E pattern) generator and detector with error injection mode; V.54 compliant—local analog loopback and remote digital loopback, activated by front panel switch or via serial interface LED Status: TD, RD, RTS, CD, DTR, ER and TM Indicators: (test mode) Isolation: Minimum 3000V RMS via transformers Surge Protection: Immune to IEC-801-5 Level 2, 1kV DCE/DTE Interface: Field-replaceable Quick ConnectTM
APPENDIX A

To gain optimum performance from the Model 1094 Series, please keep the following guidelines in mind:
The Patton Model 1094 operates at frequencies of 512 kHz or less and has been performance tested by Patton technicians using twisted-pair cable with the following characteristics:
19 AWG/0.9mm 83nF/mi or 15.72 pF/ft. .0163 Ohms/ft. 22 AWG/0.6mm 83nF/mi or 15.72 pF/ft. .0326 Ohms/ft. 24 AWG/0.5mm 83nF/mi or 15.72 pF/ft. .05165 Ohms/ft. 26 AWG/0.4mm 83nF/mi or 15.72 pF/ft. .08347 Ohms/ft.
Wire Gauge Capacitance Resistance
19 AWG ( 0.9 mm) 384 4.9(7.9) 3.4(5.5) 2.7(4.3) 1.9(3.1) 768 3.1(4.9) 2.2(3.5) 1.8(2.9) 1.3(2.0)
Model 1094 Distance Table in Miles (km)
22 AWG (0.6mm)
24 AWG (0.5 mm)
26 AWG (0.4 mm)
Patton Model # Description
0805US American Power Cord 0805EUR European Power Cord CEE 7 0805UK United Kingdom Power Cord 0805AUS Australia/New Zealand Power Cord 0805DEN Denmark Power Cord 0805FR France/Belgium Power Cord 0805IN India Power Cord 0805IS Israel Power Cord 0805JAP Japan Power Cord 0805SW Switzerland Power Cord 07M1090SVC Service Manual 07M1094 User Manual
PATTON ELECTRONICS MODEL 1094 FACTORY REPLACEMENT PARTS AND ACCESSORIES
Data Rate (kbps) · Wire Gauge

RS-232, RS-530 Interface Pin Description (DB-25 Female Connector) (DCE Configuration)
1 FG (Frame Ground) 2 TD (Transmit Data) 3 RD (Receive Data) 4 RTS (Request to Send) 5 CTS (Clear to Send) 6 DSR (Data Set Ready) 7 SGND (Signal Ground) 8 CD (Carrier Detect) 9 RC/ (Receive Timing-B) 10 CD/ (Carrier Detect-B) 11 XTC/ (External Transmit Clock) 12 TC/ (Test Control-B) 13 CTS/ (Clear to Send) 14 TD/ (Transmit Data-B) 15 TC (Test Control-A) 16 RD (Receive Data) 17 RC (Receive Timing) 18 LLB (Local Line Loop) 19 RTS/ (Request to Send) 20 DTR (Data Transfer Rate) 21 DL (Remote Digital Loop) 22 DSR/ (Data Set Ready) 23 DTR/ (Data Transfer Rate) 24 XTC (External Transmit Clock) 25 TM (Test Mode)
Pin # Signal
B SGND (Signal Ground) C RTS (Request to Send) D CTS (Clear to Send) E DSR (Data Set Ready) F CD (Carrier Detect) H DTR (Data Transfer Ready) L LLB (Local Line Loop) M TM (Test Mode) N RDL (Remote Digital Loop) P TD(Transmit Data) R RD (Receive Data) S TD/ (Transmit Data-B) T RD/ (Receive Data-B) U XTC (External Transmit Clock) V RC(Receive Timing) W XTC/ (External Transmit Clock) X RC/ (Receive Timing) Y TC(Test Control-A) AA TC/ (Test Control-B)
PATTON ELECTRONICS MODEL 1094 INTERFACE PIN ASSIGNMENTS (Continued)
V.35 Interface (M/34F Female Connector) (DCE Configuration)
Pin # Signal

1 Frame Ground 2 T (Transmit Data-A) 3 C (Control-A) 4 R (Receive Data-A) 5 I (Indication-A) 6 S (Signal Element Timing-A) 7 BT (Byte Timing-A) 8 SGND (Signal Ground) 9 T/ (Transmit Data-B) 10 C/ (Control-B) 11 R/ (Receive Data-B) 12 I/ (Indication-B) 13 S/ (Signal Element Timing-B) 14 BT/ (Byte Timing-B)
PATTON ELECTRONICS MODEL 1094 INTERFACE PIN ASSIGNMENT (Continued)
X.21 Interface (DB-15 Female Connector) (DTE /DCE Configuration)
Copyright © 1997 Patton Electronics Company All Rights Reserved
Pin # Signal
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Figure 5. Local Analog Loop | p.8 | ||
| To perform an Analog Loopback test, follow these steps: A. Activate Local Analog Loopback. This may be done in one of two ways: First, by moving the front panel toggle switch UP to Local. Second, by raising signal LOCAL LOOPBACK on the terminal interface (for pin numbers, see Appendix D). Once LAL is activated, the Model 1094 transmit output is connected to its own receiver. The TM LED should be lit. (continued) | p.8 | ||
| To perform an Analog Loopback test, follow these steps: A. Activate Local Analog Loopback. This may be done in one of two ways: First, by moving the front panel toggle switch UP to Local. Second, by raising signal LOCAL LOOPBACK on the terminal interface (for pin numbers, see Appendix D). Once LAL is activated, the Model 1094 transmit output is connected to its own receiver. The TM LED should be lit. (continued) | p.8 | ||
| Remote 1094 Local 1094 | p.9 | ||
| Remote 1094 Local 1094 | p.9 | ||
| Figure 6. Remote Digital Loop | p.9 | ||
| To perform an RDL test, follow these steps: A. Activate RDL. This may be done in one of two ways: First, by moving the front panel toggle switch DOWN to “Remote”. Or, second, by raising the REMOTE LOOPBACK signal on the terminal interface (for pin numbers, see Appendix D). B. Perform a BER (bit error rate) test on the system, using BER testers on both ends. C. If the BER test equipment indicates a fault and the Local Analog Loopback test was successful for both Model 1094s, you may have a problem with the line between the Model 1094s. You should inspect the line for proper connections. | p.9 | ||
| To perform an RDL test, follow these steps: A. Activate RDL. This may be done in one of two ways: First, by moving the front panel toggle switch DOWN to “Remote”. Or, second, by raising the REMOTE LOOPBACK signal on the terminal interface (for pin numbers, see Appendix D). B. Perform a BER (bit error rate) test on the system, using BER testers on both ends. C. If the BER test equipment indicates a fault and the Local Analog Loopback test was successful for both Model 1094s, you may have a problem with the line between the Model 1094s. You should inspect the line for proper connections. | p.9 |