MODEL 1092A High Speed, 2-Wire/4-Wire, Sync & Async Short Range Modem

Part# 07M1092A-E Doc# 033031UD Revised 03/29/00
SALES OFFICE (301)975-1000 TECHNICAL SUPPORT (301)975-1007 http://www.patton.com
An ISO-9001 · Certified Company



1.3 SERVICE
Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to contact Patton Electronics Technical Support at (301) 975-1007.
All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Service at:
tel: (301)975-1007; email: support@patton.com; or, www: http://www.patton.com.
Patton Electronics' technical staff is also available to answer any questions that might arise concerning the installation or use of your Model 1092A. Technical Service hours: 8AM to 5PM EST, Monday through Friday.
The Patton Electronics Model 1092A KiloModem 2W/4WTM baseband modem allows synchronous or asynchronous data transmissions up to 11 miles (17.6 km) over one or two twisted pair (2 or 4 Wire). Supporting synchronous speeds up to 128 kbps and asynchronous speeds up to 38.4 kbps, the 1092A widens the bottleneck for high speed LAN interconnection or high speed internet links.
The Model 1092A is remotely manageable when connected to a rack-mounted Model 1092ARC and using a Model 1001MC Management Card. Perfect for synchronous tail-circuit applications, the Model 1092A supports internal, external or receive loopback synchronous clocking. Data rates and asynchronous data format may be configured locally using DIP switches.
The Model 1092A features replaceable DCE-DTE interface modules. Available interfaces include V.24/RS-232, V.35, RS-422/530, G.703, X.21, and 10BaseT Ethernet. Line connection is made by RJ- 45C jack. The standard Model 1092A is powered by a 100/230VAC(Universal) supply. The internal DC power supply option supports any DC input between 40-60VDC.

2.3 1092A SNMP MANAGEMENT SOLUTIONS
The Model 1092A is equipped with two sets of eight DIP switches, which allow configuration of the unit to a wide variety of applications. This section describes switch locations and explains all possible configurations.
Model 1092A is SNMP manageable when it is connected to a rack-mounted Model 1092ARC . SNMP management is enabled through a 1001MC rack management card located in the Patton Electronics Rack System.
2.3.1 HTTP/HTML Management
The Model 1092A uses a unique set of 16 external mini DIP switches that allow configuration to a wide range of applications. The 16 external switches are grouped into two eight-switch sets, and are externally accessible from the underside of the Model 1092A (See Figure 2).
The 1001MC maintains HTML pages that can be viewed through a web browser. You can display remote statistics and configure Model 1092A parameters simply by entering the 1001MC’s IP address into the browser


Front Back
OFF
S1
Figure 2. Underside of Model 1092A, Showing Location of DIP Switches
The two sets of DIP switches on the underside of the Model 1092A will be referred to as S1 and S2. As Figure 3 shows the orientation of all DIP switches is the same with respect to “ON” and “OFF” positions.

OFF
Figure 3. Close Up of Configuration Switches (both sets are identical in appearance)

3.1.1 Configuration DIP Switch Set “S1”
Use the eight switches in DIP Switch Set “S1” to configure the data rate, asynchronous or synchronous data format, transmit clock source and response to RDL request. The following table summarizes default positions of DIP Switch S1. Detailed descriptions of each switch follow the table.
Use Switch S1-3 to control the behavior of the DSR signal at the EIA interface during the line loopback test.
S-3 Setting On DSR is on during local line loop Off DSR is off during local line loop
When setting the 1092A to SNMP Management, the DTE rate switches (S1-1, S1-2, and S2-1) are also needed to be at the ON position. Therefore, to set a 1092A unit SNMP management mode, the following switches have to be at the ON position, S1-1, S1-2, S2-1, and S1-4.
Use Switch S1-4 to configure the 1092A’s management setting.
S1-4 Setting On SNMP Management Off Control Port Management
Always at off position
Use Switches S1-1 and S1-2 with Switch S2-1 to configure the Async or Sync bit rate for Model 1092A. The following table summarizes default positions of DIP Switch S2. Detailed descriptions of each switch follow the table.
Use Switches S1-6 and S1-7 to configure the 1092A for internal, external, or receive recover clock mode.
S1-6 S1-7 Clock Mode Description On On Internal System clock generated internally
Off On External (DTE) System clock derived from terminal interface
On Off Receive Recover System clock derived from the received line signal.
Off Off Hardware Reset Reset to use hardware switches for configuration

Use Switch S1-8 to allow Model 1092A to enter the Remote Digital Loopback diagnostic test when requested to do so by the far end Model 1092A For example, when Switch S1-8 is set to “ON”, it will enter RDL mode (See Section 5.3.2) when requested to do so by the remote Model 1092A.
Use Switch S2-3 to enable Local Line Loopback control from the local DTE interface (See Section 5.3.1).
S2-3 Activation Description Off Disabled Ignore Local Line Loop Back request from DTE interface
S1-8 Setting On Response to RDL Request Enabled Off Response to RDL Request Disabled
On Enabled Respond to Line Loop Back request from DTE interface
3.1.2 Configuration DIP Switch Set “S2”
Use the DIP Switches in Switch S2 to enable 19.2 kbps synchronous operation, 2-Wire/4-Wire configuration and loopback modes from DTE . The following table summarizes default positions of DIP Switch S2. Detailed descriptions of each switch follow the table.
Use Switch S2-4 to configure 2-Wire or 4-Wire twisted pair operation.
S2-4 Setting Description Off 2-Wire 2-Wire Operation On 4-Wire 4-Wire Operation
Use Switch S2-6 to enable RDL control from the local DTE. In the enabled setting, the 1092A responds to RDL requests from the local DTE by sending an RDL loop request to the remote Model 1092A (See Section 5.3.2).
S2-3 Activation Description Off Disabled Ignore Remote Digital Loopback request from DTE interface
On Enabled Respond to Remote Digital Loop Back request from DTE interface
Use Switch S2-1 with Switches S1-1 and S1-2 to enable additional data rates. The Table in Section 3.1.1 shows all possible bit rate settings for Switches S1-1, S1-2, and S2-1.
Use Switch S2-2 to enable or disable the front panel toggle switches.
S2-2 Setting On Disable the Front Panel Switches Off Enable the Front Panel Switches

3.2.1 Configuring the Local 1092A
The Model 1092A features a menu-driven command system that allows you to configure the local 1092A. Follow the instructions below to configure the Model 1092A using the software switches:
To configure the local 1092A, make a selection from the following MAIN MENU.

9600 Baud 8 data bits, 1 stop bit, no parity Local echo CR-CR/LF on inbound data ANSI, VT-100 emulation
Select Option 1 to display the most recent configuration of the local Model 1092A (See below). The Model 1092A uses the active configuration for its operation. If you make changes to the configuration, you must select MAIN MENU Option 8. This will update the unit to the new active configuration.
Patton Electronics Copyright
(C) 2000


Select Option 2 to display the configuration of the hardware DIP- switches. To use the Hardware Configuration for the Active Configuration, select MAIN MENU Option 5. Then select “Use Hardware DIP-Switches”. Finally, select MAIN MENU Option 8 to save the changes.
Select Option 4 to edit the software configuration of the Model 1092A. To save changes after editing the software configuration, select MAIN MENU Option 5, then select “Use Software Switches” and then select MAIN MENU Option 8.
******************************************************** * SOFTWARE CONFIGURATION MENU - Esc to MAIN MENU * 1. DTE Rate * * 2. Data Format (Async/Sync) * * 3. Clock Mode * * 4. DSR during Local Line Loop * * 5. Response to Remote Digital Loop * * 6. DTE controlled Local Line Loop * * 7. DTE controlled Digital Loop * * 8. 4-Wire/2-Wire selection ******************************************************** Enter your selection (1-7)>

Select Option 3 to display the configuration of the software switches. To use the software configuration for the Active Configuration, select MAIN MENU, Option 5. Then select “Use Software Switches”. Finally, select MAIN MENU Option 8 to save the changes.
Select Option 1 in the SOFTWARE CONFIGURATION menu to select the async. or sync. DTE Rate of the Model 1092A. The selections are shown below.



Select Option 2 in the SOFTWARE CONFIGURATION Menu to select the async or sync data format (See below).
Select Option 4 in the SOFTWARE CONFIGURATION to configure the behavior of the local Data Set Ready (DSR) signal during the Local Line Loop test mode (below).


Select Option 3 in the SOFTWARE CONFIGURATION Menu to select the sync clock mode (See below).
Select Option 5 in the SOFTWARE CONFIGURATION Menu to instruct the Model 1092A to either respond or ignore the Remote Digital Loop request from the remote 1092A.


Set this option as follows:
Master Clock - Internal: Selection 1 allows the Model 1092A to generate an internal clock as the timing source.
Master Clock - External: Selection 2 allows the Model 1092A to Derive the system clock from the locally connected DTE.
Select Option 6 in the SOFTWARE CONFIGURATION Menu to instruct the Model 1092A to either respond or ignore Local Line Loop requests from the DTE. To instruct the Model 1092A to respond to Local Line Loop requests from the DTE, select Enable (Option 1). To instruct the 1092A to ignore Local Line Loop requests from the DTE interface, select Disable (Option 2).
Slaved to Receive Clock: Selection 3 to allows the Model 1092A to derive the timing source from the incoming data stream from the remote Model 1092A.


Select Option 7 in the Menu to enable DTE control of the Remote Digital Loop Menu (See below). The
Select Option 6 from MAIN MENU to display the Modem Status (below). Press the space bar on the keyboard to update and redisplay the screen.
interface by selecting Enable (Option 1). To instruct the 1092A to ignore this request from the DTE interface, select Disable (Option 2).


Select Option 8 in the SOFTWARE CONFIGURATION configure 2-Wire or 4-Wire operation.
******************************************************* * 2-Wire/4-Wire Selection * * 1. 4-Wire Mode * * 2. 2-Wire Mode *******************************************************
Select Option 7 from the MAIN MENU to select the test mode status of the Model 1092A. (below). The Model 1092A Test Mode settings help to verify the integrity of the data link and isolate communication difficulties.
MAIN MENU selects whether the Model

settings for its active configuration. If Options 1 or 2 are selected, the 1092A will use the current hardware or software switch settings as the
Option 8 to implement the changes.


The Model 1092A Test Modes are described on the following page.
Once the Model 1092A is properly configured, it is ready to connect to the twisted pair interface, to the serial port, and to the power source. This section tells you how to make these connections.
To run or terminate a particular test, key in the option to get to that screen menu.
OFF Terminates all tests
The Model 1092A supports communication between two DTE devices at distances to 5 miles (8 km) over 24AWG (.5mm) twisted pair wire. There are two essential requirements for installing the Model 1092:
511 Initiates the built-in test pattern generator and detector.
511 with Errors Initiates the built-in test pattern generator and detector. The test pattern generator also injects intentional errors approximately once per second.
Local Line Loop Initiates the Local Line Loop test and starts and 511 the internal 511 generator and detector.
Local Line Loop Initiates the Local Line Loop test and starts and 511 w/errors the internal 511 generator and detector. In this test, the 511 pattern generator injects intentional errors into the data stream.
Remote Digital Initiates the Remote Digital Loopback test. Loop Any data sent to the remote 1092A is returned to the originating device.
The RJ-45 connector on the Model 1092A’s twisted pair interface is polarity insensitive and is wired for a two-wire or four-wire interface. The signal/pin relationships are shown in Figure 4 below.
Remote Digital Initiates the Remote Digital Loopback test Loop and 511 and starts the internal 511 generator and detectors.
Remote Digital Initiates the Remote Digital Loopback test Loop and and starts the 511test patterns. In this test 511 with errors the 511 pattern generator will inject initial errors into the data stream.

1 (N/C) 2 (GND) 3 (4-Wire Rx) 4 (2-Wire TIP/4-Wire Tx) 5 (2-Wire RING/4-Wire Tx) 6 (4-Wire Rx) 7 (GND) 8 (N/C)
1 2 3 4 5 6 7 8
The Modem Status Screen is displayed upon initiating a test. Press ‘ESC’ to return to the Test Mode Menu.
Press the space bar to update and redisplay the status.
Figure 4. Model 1092A twisted pair line interface.

SIGNAL PIN# PIN# SIGNAL
The serial port interface on the Model 1092A uses interchangeable QuikConnect™ Modules. Each QuikConnect™ Module has a 50-pin card edge connector on one side and a serial port interface on the other. Figure 5 below shows how a QuikConnect™Module plugs into the back of the Model 1092A.

Tx 4 3 Rx Tx 5 6 Rx
Rx 3 4 Tx Rx 6 5 Tx
Figure 5. Installation of Model 1092A Plug-in Serial Interface Module
4.2.1 Changing QuikConnect™Modules
When you purchase a particular version of the Model 1092A, it should be shipped to you with the appropriate QuikConnect™Module already installed. If you need to install a different QuikConnect™ Module, follow these steps:
Removing the Existing QuikConnect™Module
Installing the New QuikConnect™Module

4.2.4 Configuring the X.21 QuikConnect™ Module
The serial port on the X.21 QuikConnect™Module is default wired as a DCE, but may be switched to a DTE. This is done by reversing the orientation of the DCE/DTE strap, as described below:
To reverse DCE/DTE orientation, remove the module according to the instructions in Section 4.2.1. The DCE/DTE strap is located on the bottom side of the module’s PC board. The arrows on the top of the strap indicate the configuration of the X.21 port (for example, if the DCE arrows are pointing toward the DB-15 connector, the X.21 port is wired as a DCE). Reverse the DCE/DTE orientation by pulling the strap out of its socket, rotating it 180º, then plugging the strap back into the socket. You will see that the DCE/DTE arrows now point in the opposite directions, showing the new configuration of the X.21 port. Reinstall the module according to the instructions in Section 4.2.1.
The Model 1092A is available with two power supply options:
Universal Interface AC Power Supply option (Model 1092A-UI) operates in environments ranging from 100 to 253 VAC, with no re- configuration necessary (see Appendix B for available domestic and international power cords).
4.2.2 Connecting to a “DTE” Device
The serial port on most QuikConnect™interface modules (all except the X.21 module) is hard-wired as a DCE. Therefore these modules “want” to plug into a DTE such as a terminal, PC or host. When making the connection to your DTE device, use a straight through cable of the shortest possible length—we recommend 6 feet or less. When purchasing or constructing an interface cable, please refer to the pin diagrams in Appendix C as a guide.
DC Power Supply option (Model 1092A-DC) operates in 48 VDC environments and is equipped with a 3-pin “terminal strip” style connector.
4.3.1 Connecting to an AC Power Source
4.2.3 Connecting to a “DCE” Device
The Universal Interface AC Supply is equipped with a male IEC-320 power connection. A domestic (US) power supply cord is supplied with the unit at no extra charge. To connect the standard or universal power supply, follow these steps:
If the Model 1092A’s QuikConnect™ interface module is hard- wired as a DCE (all except the X.21 module), you must use a null modem cable when connecting to a modem, multiplexer or other DCE device. This cable should be of the shortest possible length—we recommend 6 feet or less. When purchasing or constructing a null modem interface cable, use the pin diagrams in Appendix C as a guide.

4.3.2 Connecting to a DC Power Source
Once the Model 1092A is properly configured and installed, it should operate transparently. This sections describes power-up, reading the LED status monitors, and using the built-in loopback test modes.
The 48 VDC power supply option uses a 3-pin terminal block with spring-type connectors. Please refer to the Model 1090 Series Service Manual.
5.1 POWER-UP To apply power to the Model 1092A, first be sure that you have read Section 4.3, and that the unit is connected to the appropriate power source. Then power-up the unit using the rear power switch.
5.2 LED STATUS MONITORS The Model 1092A features eight front panel LEDs that monitor power, the DTE signals, network connection and test modes. Figure 6 (below) shows the front panel location of each LED. Following Figure 6 is a description of each LEDs function.

Figure 6. Model 1092A Front Panel
TD & RD Glows yellow to indicate an idle condition of Binary “1” data on the respective terminal interface signals. Green indicates Binary “0” data.
CTS Glows green to indicate that the Clear to Send signal from the modem is active. Yellow indicates an inactive Clear to Send signal from the modem.
CD Glows yellow if no carrier signal is being received from the remote modem. Green indicates that the remote modem’s carrier is being received.
DTR Glows green to indicate that the Data Terminal Ready signal from the terminal is active.
ER Glows red to indicate the likelihood of a Bit Error in the received signal. During the 511 or 511/E test, ER will flash to indicate that the Test Pattern Detector has detected a bit error.
TM Glows yellow to indicate that the Model 1092A has

been placed in Test Mode. The unit can be placed in test mode by the local or remote user.
5.3.2 Remote Digital Loopback (RDL)
NS Glow red to indicate that the local Model 1092A has not yet connected with the remote
The Remote Digital Loopback (RDL) test checks the performance of both the local and remote Model 1092As, and the communication link between them. Any characters sent to the remote Model 1092A in this test mode will be returned back to the originating device (see Figure 8, below). For example, characters typed on the keyboard of the local terminal will appear on the local terminal screen after having been passed to the remote Model 1092A and looped back.
The Model 1092A offers two proprietary loopback test modes, plus a built-in V.52 BER test pattern generator, to evaluate the condition of the modems and the communication link. These tests can be activated physically from the front panel, or via the interface.
5.3.1 Local Line Loopback (LLB) The Local Line Loopback (LLB) test checks the operation of the local Model 1092A, and is performed separately on each unit. Any data sent to the local Model 1092A in this test mode will be echoed (returned) back to the user device (see Figure 7, below). For example, characters typed on the keyboard of a terminal will appear on the
Local 1092A Remote 1092A

Figure 8. Remote Digital Loop

To perform an RDL test, follow these steps:
Figure 7. Local Line Loopback
terminal screen.
- Move the front panel toggle switch to the Left to “Remote”. - Raise the RDL signal on the interface (see Appendix C). - Set Remote Loopback from the VT100 screen.
To perform an LLB test, follow these steps: 1. Activate LLB. This may be done in one of three ways: - Move the front panel toggle switch to the right to
“Local”. - Raise the LLB signal on the interface (see Appendix C). - Set Local Loop from the VT100 screen.
Once LLB is activated, the Model 1092A transmitter output is connected to its own receiver. Data is also looped back to the line. The “TM” LED should be lit.
RDL initiated · LLB initiated

5.3.3 Using the V.52 (BER) Test Pattern Generator
To use the V.52 BER tests in conjunction with the Remote Digital Loopback tests (or with Local Line Loopback tests), follow these instructions:
Diagnostics: V.52 compliant bit error rate pattern (511/511E pattern) generator and detector with error injection mode; Local Line Loopback and Remote Digital Loopback, activated by front panel switch or via serial interface
Connectors: RJ-45 on line side; DB-25 female, M/34 female or DB-15 female on serial interface side, depending upon which interface module is installed.
Power: 100-253 VAC, 50-60 Hz (universal input); 48 VDC (option). 10 watts.
2-Wire Distance Table in miles (km)
AWG Wire Gauge (mm)
19(.9) 22(.6) 24(.5) 6(.4)
All Rates 10.8(17.2) 7.2(11.5) 5.0(8.0) 3.4 (5.5)
4-Wire Distance Table in miles (km)
19(.9) 22(.6) 24(.5) 6(.4)
All Rates 11.4(18.2) 7.6(12.1) 5.3(8.5) 3.6(5.7)
Data Rate · Data Rate · Wire Gauge

APPENDIX C
PATTON ELECTRONICS MODEL 1092A FACTORY REPLACEMENT
PATTON ELECTRONICS MODEL 1092A INTERFACE PIN
PARTS AND ACCESSORIES
ASSIGNMENT
Patton Electronics Model # Description
RS-232, RS-530 Interface Pin Description
IM1/A V.24 with DB25F IM1/B RS422/RS530 with DB25F IM1/C V.35 with M34F IM1/D X.21 with DB15F IM1/E V.35 with DB25F IM1/F 64KG.703 with RJ45 IM1/I 10BT with RJ45 IM1/JO Voice Data Module IM1/I4 10BT 4-Port Ethernet Bridge IM1/JS Voice Data Module 0805US American Power Cord 0805EUR European Power Cord CEE 7 0805UK United Kingdom Power Cord 0805AUS Australia/New Zealand Power Cord 0805DEN Denmark Power Cord 0805FR France/Belgium Power Cord 0805IN India Power Cord 0805IS Israel Power Cord 0805JAP Japan Power Cord 0805SW Switzerland Power Cord
1 FG (Frame Ground) 2 TD (Transmit Data) 3 RD (Receive Data) 4 RTS (Request to Send) 5 CTS (Clear to Send) 6 DSR (Data Set Ready) 7 SGND (Signal Ground) 8 CD (Carrier Detect) 9 RC/ (Receive Timing-B) 10 CD/ (Carrier Detect-B) 11 XTC/ (External Transmit Clock) 12 TC/ (Transmit Timing-B) 13 CTS/ (Clear to Send) 14 TD/ (Transmit Data-B) 15 TC (Trasmit Timing-A) 16 RD (Receive Data) 17 RC (Receive Timing) 18 LLB (Local Line Loop) 19 RTS/ (Request to Send) 20 DTR (Data Terminal Ready) 21 RDL (Remote Digital Loop) 22 DSR/ (Data Set Ready) 23 DTR/ (Data Terminal Ready) 24 XTC (External Transmit Clock) 25 TM (Test Mode)
(DB-25 Female Connector) · (DCE Configuration) · Pin # Signal

APPENDIX C
PATTON ELECTRONICS MODEL 1092A INTERFACE PIN
PATTON ELECTRONICS MODEL 1092A INTERFACE PIN
ASSIGNMENT
ASSIGNMENT
V.35 Interface (M/34F Female Connector)
X.21 Interface (DB-15 Female Connector)
Pin # Signal B SGND (Signal Ground) C RTS (Request to Send) D CTS (Clear to Send) E DSR (Data Set Ready) F CD (Carrier Detect) H DTR (Data Terminal Ready)
Pin # Signal 1 Frame Ground 2 T (Transmit Data-A) 3 C (Control-A) 4 R (Receive Data-A) 5 I (Indication-A) 6 S (Signal Element timing-A) 7 BT (Byte Timing-A) 8 SGND (Signal Ground) 9 T/ (Transmit Data-B) 10 C/ (Control-B) 11 R/ (Receive Data-B) 12 I/ (Indication-B) 13 S/ (Signal Element Timing-B)
L LLB (Local Line Loop) M TM (Test Mode) N RDL (Remote Digital Loop) P TD(Transmit Data) R RD (Receive Data) S TD/ (Transmit Data-B) T RD/ (Receive Data-B) U XTC (External Transmit Clock) V RC(Receive Timing) W XTC/ (External Transmit Clock)
X RC/ (Receive Timing) Y TC(Transmit Timing-A) AA TC/ (Transmit Timing-B)
14 BT/ (Byte Timing-B)

APPENDIX D APPENDIX D
PATTON ELECTRONICS MODEL 1092A PATTON ELECTRONICS MODEL 1092A
PATTON ELECTRONICS MODEL 1092A
QUICK START GUIDE QUICK START GUIDE
CONTROL PORT PIN ASSIGNMENT
The 1092A control port is an 8 position connector, compliant with EIA/TIA-561.
Pin Function RJ45 Pin No.
S1-1 "ON" S1-2 "OFF" S1-3 "ON" S1-4 and 5 "OFF" S1-6 and 7 "ON" S1-8 "ON" S2-1, 2, and 3 "OFF" S2-4 "ON" (4-wire operation) "OFF" (2-wire operation) S2-5 "OFF" S2-6, 7 and 8 "ON"
Receive data (to DTE) 5
Transmit data (from DTE) 6
S1-1 "ON" S1-2 "OFF" S1-3 "ON" S1-4 and 5 "OFF" S1-6 "ON" S1-7 "OFF" S1-8 "ON" Switch S2 settings are the same as the MASTER UNIT.