EN
Patton electronic logo
Official user manual

Patton electronic 1060

10 pages·76 KB·Network Card·PDF·ENDEFRITNLJA
Patton electronic 1060
Table of Contents 61 sections MODEL 1060 AC Powered, Asynchronous Short Range Modem · USER MANUAL · 1.2 CE NOTICE · 1.1 RADIO AND TV INTERFERENCE · … ShowHide
Page 1 of the Patton electronic 1060 user manual — MODEL 1060 AC Powered, Asynchronous Short Range Modem
Page 1 · click to enlarge
Page 1

P.S. Please tell us where you purchased this product

It is our business to serve you. If you are not satisfied with any aspect of this product or the service provided from Patton Electronics or its distributors, please let us know.

We are committed to a quality product at a quality price. Patton Electronics is BABT and ISO 9001 certified. We meet and exceed the highest standards in the industry (CE, UL, etc.).

We would like to hear from you. Please contact us in any of the following ways to tell us how you like this product and how we can meet your product needs today and in the future.

We manufacture one of the widest selections of data communications products in the world including CSU/DSU's, network termination units, powered and self-powered short range modems, fiber optic modems, interface converters, baluns, electronic data switches, data-line surge protectors, multiplexers, transceivers, hubs, print servers and much more. We produce these products at our Gaithersburg, MD, USA, facility, and can custom manufacture products for your unique needs.

Thank you for purchasing Patton Electronics products! We do appreciate your business. I trust that you find this user manual helpful.

Thank you.

Web: http://www.patton.com Sales E-mail: sales@patton.com Support E-mail: support@patton.com Phone - Sales (301) 975-1000 Phone - Support (301) 975-1007 Fax: (301) 869-9293 Mail: Patton Electronics Company 7622 Rickenbacker Drive Gaithersburg, MD 20879 USA

Burton A.Patton Vice President

An ISO-9001 Certified Company

C E R T I F I E D

Part #07M1060-C Doc. #058011C Revised 11/3/97

Patton electronic 1060 — MODEL 1060 AC Powered, Asynchronous Short Range Modem diagram (page 1)
Fig. 1 · MODEL 1060 AC Powered, Asynchronous Short Range Mode…

MODEL 1060 AC Powered, Asynchronous Short Range Modem

USER MANUAL

SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 http://www.patton.com

Dear Valued Customer,

Page 2 of the Patton electronic 1060 user manual — 1.3 SERVICE
Page 2 · click to enlarge
Page 2

The CE symbol on your Patton Electronics equipment indicates that it is in compliance with the Electromagnetic Compatibility (EMC) directive and the Low Voltage Directive (LVD) of the Union European (EU). A Certificate of Compliance is available by contacting Technical Support.

1.2 CE NOTICE

The Model 1060 generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television reception. The Model 1060 has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the Model 1060 does cause interference to radio or television reception, which can be determined by disconnecting the RS-232 interface, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).

1.1 RADIO AND TV INTERFERENCE

Patton Electronics warrants all Model 1060 components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.

1.0 WARRANTY INFORMATION

Patton Electronics' technical staff is also available to answer any questions that might arise concerning the installation or use of your Model 1060. Technical Service hours: 8AM to 5PM EST, Monday through Friday.

All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Service at (301) 975-1007, http://www.patton.com or support@patton.com.

1.3 SERVICE

Page 3 of the Patton electronic 1060 user manual — ON
Page 3 · click to enlarge
Page 3

The Model 1060 is housed in a sturdy metal case and comes with either 115 or 220V external transformers. This is the top-of-the-line in asynchronous short range modems.

In addition, the Model 1060 is perfect for low power RS-232 environments. The new Model 1060 is AC powered, and therefore is the recommended solution for RS-232 environments whose interface voltages are below RS-232 specifications. The Model 1060 supports data rates to 115.2 Kbps and extends RS-232 transmission distances up to 14 miles over two twisted pair.

The Model 1060 Series asynchronous short range modem is equipped with a virtual wish list of “bells and whistles”: Point-to-point or multipoint applications are supported. Two separate control signals may be passed (one each way), each with switch-selectable pin assignments. Data lines are protected from ground loops and electrically volatile environments by optical isolation and Silicon Avalanche Diodes. System integrity can be evaluated using two built-in test modes: local analog loopback and remote analog loopback. Tri- state LEDs monitor transmit data, receive data and control signals. Finally, 4-wire connections may be made using either RJ-11 jack or terminal blocks—both are included.

2.2 DESCRIPTION

2.1 FEATURES

Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to contact Patton Electronics Technical Support at (301) 975-1007.

  • Data rates to 115.2 Kbps
  • Built-in optical isolation & high speed surge protection
  • Distances up to 14 miles (19 AWG TWP @ 1200 bps)
  • Tri-state LED indicators
  • Point-to-point or multipoint
  • Local and remote loopback test modes
  • DCE/DTE switch selectable
  • Hardware and software flow control support
  • Externally powered
  • Made in the U.S. A.

2.0 GENERAL INFORMATION

If you are installing these units in a point-to-point application with a computer, printer or terminal, configure the DIP switches on both Model 1060s as follows:

3.1.1 POINT-TO-POINT CONFIGURATION

In the majority of applications, you won't need an in-depth knowledge of the Model 1060's capabilities to get up and running. The following "quick set-up" DIP switch configurations cover most Model 1060 operating environments. (Note: DIP switch 8 not used)

3.1 "QUICK SET-UP" INSTRUCTIONS

The Model 1060 features externally accessible configuration switches, located on the underside of the unit; there is no need to open the case to configure the Model 1060. Figure 1 (below) shows the location of the DIP switch set, as well as the two DCE/DTE switches.

Switch Number: 1 2 3 4 5 6 7 Positions OFF OFF OFF ON ON ON OFF

Figure 1. Switch locations underneath Model 1060

3.0 CONFIGURATION

1 2 3 4 5 6 7 8

ON

DTE DCE

DTE DCE

REAR

FRONT

DIP Switches

Page 4 of the Patton electronic 1060 user manual — 3.1.2 MULTIPOINT CONFIGURATION
Page 4 · click to enlarge
Page 4

3.3 SPECIAL CONFIGURATION

Correct setting of the DCE/DTE switches eliminates the need for RS-232 crossover cables. If the RS-232 device you are connecting to the Model 1060 is a PC, terminal or host, or is wired like one, set both of the DCE/DTE switches to "DCE". If the RS-232 device you are connecting to the Model 1060 is a modem or multiplexer, or is wired like one, set both of the DCE/DTE switches to "DTE".

3.2 DCE/DTE SWITCH SETTINGS

The Model 1060 supports multipoint operation in either daisy chain or star configurations. For multipoint configuration and wiring information, refer to Section 4.2, pages 7.

3.1.2 MULTIPOINT CONFIGURATION

**Multiple output pins generate the same signal simultaneously

*Multiple input pins are "or-tied"—if any input goes low, carrier is dropped

Table 1. All possible switch settings for the Model 1060 5

Mode (DCE/DTE)Control Input (CIn)Control Output (COut)+Voltage Output (VOut)Carrier Controlled by (CIn)Switch Settings 1234567 DCE4 4 4,11,20* 4,11,20* 4 4 4,11,20* 4,11,20*8 66 8Disabled Enabled Disabled Enabled Disabled Enabled Disabled EnabledON ON OFF OFF ON ON OFF OFFON OFFON OFFOFF OFF ON ON OFF OFF ON ONOFF ONOFF ONOFF ON OFF ON OFF ON OFF ON DTE8 8 5,6,8* 5,6,8* 8 8 5,6,8* 5,6,8*4 11,20**11,20** 4Disabled Enabled Disabled Enabled Disabled Enabled Disabled EnabledON ON OFF OFF ON ON OFF OFFON OFFON OFFOFF OFF ON ON OFF OFF ON ONOFF ONOFF ONOFF ON OFF ON OFF ON OFF ON

+Voltage Output (+Vout):

The Control Output signal is transmitted by the local Model 1060 to its attached DTE device. This signal should be the same logic state as the Control Input signal on the remote 1060. This signal is required in half-duplex/switched carrier environments or in hardware flow control applications.

Control Output (Cout):

The Control Input signal is used by the local Model 1060 as an input signal to activate its transmitter (“Enabled” settings) and allow data transmission to the remote device. This is required for half-duplex/ switched-carrier environments as well as in hardware flow control applications. In the “Disabled” settings, the 1060 is always “turned on” and sends a continuous carrier to the remote 1060.

Control Input (Cin):

Switch Settings

Page 5 of the Patton electronic 1060 user manual — GND † 1 6 GND †
Page 5 · click to enlarge
Page 5

If your two twisted pair line terminates in bare wires, strip the ends and connect the individual leads to each Model 1060's terminal block. Be sure the end-to-end connections follow the diagram above.

4.1.1 TWISTED PAIR CONNECTION USING TERMINAL BLOCKS

These short range modems are designed to work in pairs. You will need one at each end of a 4-wire twisted pair circuit. The pairs must be "dry" (unconditioned) metallic wire, 19 - 26 AWG. The smaller gauges limit distance somewhat compared with larger gauges. When you have completed wiring for your data circuit, the pin connections should be as shown below:

4.1 TWISTED PAIR WIRING OVERVIEW

The Model 1060 is easy to install. After configuring the DIP switches and DCE/DTE switches, connect the two twisted pairs using one of two methods: terminal blocks or RJ-11 jack. Figure 2 (below) shows the location of the terminal blocks and RJ-11 jack, as well as the female DB-25, on the rear of the Model 1060.

Powered Async. Short Range Modem

XMT + RCV+ XMT - RCV - G G RCV - XMT - RCV + XMT +

Figure 2. Rear view of 1060 showing interface connectors

4.0 INSTALLATION

To Shield (Optional) } One Pair

RX+ RXGND TXTX+

Made In The USA

} One Pair

‡Standard color codes—yours may be different

†Connection to ground is optional

For proper signal crossing between two Model 1060s using RJ-11 connectors, pin-out the twisted pair cable according to the diagram below.

If your two-pair cable is terminated in an RJ-11 plug, you may use the RJ-11 jack in the back of the Model 1060 to make the connection. The RJ-11 jack on a Model 1060 series Short Range Modem is prewired for a standard TELCO wiring environment. To be sure you have the right wiring, use the diagram below as a guide.

4.1.2 TWISTED PAIR CONNECTION USING RJ-11

RCV- 2 4 XMT- XMT+ 3 5 RCV+ XMT- 4 2 RCV- RCV+ 5 3 XMT+ GND† 6 1 GND†

GND † 1 6 GND †

SIGNAL PIN# PIN# SIGNAL

RJ-11 SIGNAL 1 GND †

AT&T standard modular color codes

2 RCV- 3 XMT+ 4 XMT- 5 RCV+ 6 GND†

1. Blue 2 - Yellow 3 - Green 4 - Red 5 - Black 6 - White

Line Power · RS-232 Interface

Page 6 of the Patton electronic 1060 user manual — HOST FIRST SLAVE SECOND SLAVE
Page 6 · click to enlarge
Page 6

In a multipoint topology, you must configure the master Model 1060's DIP switches differently than those of the slave Model 1060(s). Here are the proper DIP switch settings for a daisy chain topology:

Figure 3 (below) shows how to wire the two-pair cables properly for a Model 1060 daisy chain topology. Note that the ground connection is not needed.

Using a daisy chain topology, you may connect as many as 10 Model 1060s together in a master/slave arrangement. Maximum distance between the units will vary based upon the number of drops, data rate, wire gauge, etc. Call Patton Technical Support for specific distance estimates.

4.2.1 DAISY CHAIN TOPOLOGY

The Model 1060 supports multi-point applications using either a star or daisy chain topology. Both topologies require special wiring, as well as specific DIP switch settings for master and slave units.

4.2 WIRING FOR MULTIPOINT CIRCUITS

Switch Number 1 2 3 4 5 6 7 Master Positions ON ON ON OFF Slave Positions ON ON ON OFF OFF OFF ON

XMT+ RCV+ RCV+ XMTRCVRCVRCV+ XMT+ XMT+ RCVXMTXMT-

HOST FIRST SLAVE OTHER SLAVE(S)

Figure 3. Model 1060 daisy chain wiring

To connect the Model 1060 to a piece of data terminal or data communications hardware, use a straight through RS-232 cable. Plug the cable directly into the DB-25 port on the rear of the Model 1060. The DCE/DTE switches eliminate the need for a crossover cable.

4.3 RS-232 CONNECTION

In a multipoint topology, you must configure the master Model 1060's DIP switches differently than those of the slave Model 1060(s). Here are the proper DIP switch settings for a star topology:

Figure 4 (below) shows how to wire the two-pair cables properly for a Model 1060 star topology. Note that the ground connection is not needed.

Using a star topology, you may connect several Model 1060s together in a master/slave arrangement. Maximum distance between the units will vary based upon the number of drops, data rate, wire gauge, etc. Call Patton Technical Support for specific distance estimates.

4.2.2 STAR TOPOLOGY

Switch Number 1 2 3 4 5 6 7 Master Positions ON ON ON OFF Slave Positions ON ON ON OFF OFF OFF ON

HOST FIRST SLAVE SECOND SLAVE

RCVXMTXMT-

RCV+ XMT+ XMT+

XMTRCVRCV-

XMT+ RCV+ RCV+

Figure 4. Model 1060 star wiring

Page 7 of the Patton electronic 1060 user manual — TX+
Page 7 · click to enlarge
Page 7

The first test mode is Local Analog Loop (V.54 Loop 3). Any data sent to the local Model 1060 in this mode will be echoed (returned) back to the user device. For example, characters typed on the keyboard of a terminal will appear on the terminal screen (see Figure 5 on the following page).

5.2.1 LOCAL ANALOG LOOP

Select the test modes by depressing the "Loopback Test" switch. When in loopback mode, the "Loopback Test" LED will glow red. Two tests are possible using this switch: Local Analog Loop (LAL), and Remote Analog Loop (RAL).

5.2 LOOPBACK TEST MODES

4. The control in and control out indicators glow red for a "low" signal and green for a "high" signal. The specific pin number associated with these indicators will vary according to the switch settings you have selected (see Section 3.0 Configuration).
3. The tri-state TD and RD indicators blink red and green with data activity. Solid red indicates a low RS-232 logic level and no color indicates no activity on the line. Note: RS-232 devices idle in a low state, so the LED will glow red if the connections are correct and the RS-232 device is in an idle state.
2. The loopback test LED glows when the loopback test switch has been depressed and is in a test mode.

The Model 1060 incorporates six front panel LEDs that show the status of the modem:

5.1 LED INDICATORS

Once you have configured each Model 1060 properly and connected it, simply plug in the AC power adapter to get it running; there is no power switch on the Model 1060. You can monitor the operation of the Model 1060 using the front panel LED indicators and built-in loopback test modes.

1. The power LED glows when AC power is applied to the modem.

5.0 OPERATION

The second test mode is Remote Analog Loop. To enter this mode, set one of the Model 1060s (local) in test mode by depressing the "Loopback Test" switch. Any characters sent from the remote 1060 will be returned to it (see Figure 5). If no characters are echoed back, check the wiring between the two Model 1060s. Be sure to wire the units according to the instructions in Section 4.0 Installation.

5.2.2 REMOTE ANALOG LOOP

RD

TD

RD

TD

Local 1060 In Loopback Mode

Local 1060 In Normal Mode

RX+

RX-

TX-

TX+

Figure 5. Loopback Test Modes

RX+

RX-

TX-

TX+

Remote 1060 In Normal Mode

Remote 1060 In Normal Mode

TX+

TX-

RX-

RX+

TX+

TX-

RX-

RX+

TD

RD

TD

RD

Page 8 of the Patton electronic 1060 user manual — APPENDIX B
Page 8 · click to enlarge
Page 8
Weight13.2 oz. (without transformer)
Dimensions4.127"W x 1.52"H x 5.0"L
Humidity5 to 95% noncondensing
Altitude0-15,000 feet
Temperature Range0-60°C (32-140°F)
Power SupplyWall mount, 9-12VAC, 200ma
Surge SuppressionOver-voltage protection for opto-Isolators
Optical Isolation2500V RMS (minimum)
DiagnosticsLocal Analog Loopback (LAL), Remote
IndicatorsTri-state for transmit data, receive data,
ApplicationsPoint-to-point or multipoint
Data Rates0 - 115,200 bps
Twisted Pair InterfaceTerminal blocks, RJ-11 jack
Serial InterfaceEIA RS-232 (CCITT V.24), DB-25 female
Range(See table on page 14)
Transmission Line19 to 26 AWG twisted pair
Transmission FormatAsynchronous

via Silicon Avalanche Diodes

control in, control out; dual-state for power,

Model 1060 Distance Table in Miles (km) Data RateWire Gauge 19 (.9mm)22 (.5mm)24 (.4mm) 115,2001.8 (2.9).75 (1.2).38 (.6) 57,6002.5 (4.0)1.3 (2.1).95 (1.5) 38,4003.7 (6.0)1.5 (2.4)1.33 (2.1) 19,2004.17 (6.7)1.9 (3.1)1.42 (2.3) 9,6005.41 (8.7)2.6 (4.2)2.08 (3.3) 4,8007.05 (11.3)3.8 (6.1)2.84 (4.6) 2,40011.5 (18.5)7.0 (11.3)4.83 (7.8) 1,20014.0 (22.5)8.5 (13.7)5.68 (9.1)

To reduce the potential of difficulties in the field, we recommend that the cable used to connect the Model 1060s have a capacitance of no greater than 20pF/ft., and that the wire be no thinner than 26 AWG. The Model 1060 is designed to withstand normal environmental noise and conditions. However, other environmental factors too numerous to discuss may affect proper operation. The distance table above should be used as a general guideline only.

Using the above characteristics as a baseline, we estimate the distance limitations for the Model 1060 to be as follows.

The Patton Model 1060 is designed and tested to communicate over twisted-pair cable with the following characteristics:

19 AWG 83nF/mi or 15.72 pF/ft. .0163Ω/ft. 22 AWG 83nF/mi or 15.72 pF/ft. .0326Ω/ft. 24 AWG 83nF/mi or 15.72 pF/ft. .05165Ω/ft.

Wire Gauge Capacitance Resistance

PATTON MODEL 1060 CABLE RECOMMENDATIONS

Data Rate 115,200 1.8 (2.9) .75 (1.2) .38 (.6) 57,600 2.5 (4.0) 1.3 (2.1) .95 (1.5) 38,400 3.7 (6.0) 1.5 (2.4) 1.33 (2.1) 19,200 4.17 (6.7) 1.9 (3.1) 1.42 (2.3) 9,600 5.41 (8.7) 2.6 (4.2) 2.08 (3.3) 4,800 7.05 (11.3) 3.8 (6.1) 2.84 (4.6) 2,400 11.5 (18.5) 7.0 (11.3) 4.83 (7.8) 1,200 14.0 (22.5) 8.5 (13.7) 5.68 (9.1)

Model 1060 Distance Table in Miles (km)

Wire Gauge 19 (.9mm) 22 (.5mm) 24 (.4mm)

APPENDIX B

Analog Loopback (RAL) · test

Page 9 of the Patton electronic 1060 user manual — APPENDIX D BLOCK DIAGRAM
Page 9 · click to enlarge
Page 9

From Model 1060 Data Term. Ready (DTR) - 20

DIRECTION STANDARD "DCE" SETTING DIRECTION

DIRECTION STANDARD "DTE" SETTING DIRECTION

To Model 1060 Data Term. Ready (DTR) - 20

PATTON MODEL 1060 INTERFACE PIN ASSIGNMENTS

APPENDIX C

1. (FG) Frame Ground 2- (TD) Transmit Data From Model 1060 3- (RD) Receive Data To Model 1060 4- (RTS) Request to Send From Model 1060 5- (CTS) Clear to Send To Model 1060 6- (DSR) Data Set Ready To Model 1060 7- (SG) Signal Ground 8- (DCD) Data Carrier Detect To Model 1060
1. (FG) Frame Ground 2- (TD) Transmit Data To Model 1060 3- (RD) Receive Data From Model 1060 4- (RTS) Request to Send To Model 1060 5- (CTS) Clear to Send From Model 1060 6- (DSR) Data Set Ready From Model 1060 7- (SG) Signal Ground 8- (DCD) Data Carrier Detect From Model 1060
Patton electronic 1060 — PATTON MODEL 1060 INTERFACE PIN ASSIGNMENTS diagram (page 9)
Fig. 2

APPENDIX D BLOCK DIAGRAM

11- From Model 1060 · 11- To Model 1060

Page 10 of the Patton electronic 1060 user manual — SYMPTOM PROBLEM SOLUTION
Page 10 · click to enlarge
Page 10

"TD" and "RD" LEDs indicate activity, but "CD" LED is unlit or red (should be green)

"TD" and "RD" LEDs indicate activity, but units will not communicate or data is garbled

SYMPTOM PROBLEM SOLUTION

3. Poor twisted pair connections to Model 1060s
2. Poor quality twisted pair circuit
1. Distance/bit rate capacity exceeded
2. Poor twisted pair connections to Model 1060s
1. Defective twisted pair line
3. Improper bit rate setting
2. Improper twisted pair wiring
1. Improper RS-232 wiring

APPENDIX E TROUBLESHOOTING

3. Check screw terminal/RJ-11 connections to Model 1060s; check integrity of plug RJ-11 terminations
2. Use a different twisted pair circuit if available
1. Check specifications in Appendix B
2. Check screw terminal/RJ-11 connections to Model 1060s; check integrity of plug RJ-11 terminations
1. Test continuity of twisted pair line
3. Make sure the bit rates on all connected serial devices are the same
2. Compare your twisted pair wiring with the diagram in Section 4.1
1. Check wiring between Model 1060 and connected serial device—it should be straight through

No data transfer in either or both directions

LEDs do not light when AC power transformer is plugged into wall

SYMPTOM PROBLEM SOLUTION

APPENDIX E TROUBLESHOOTING (CONTINUED)

5. Distance specifications exceeded
4. Improper "control input" pin setting
3. Improper bit rate setting
2. Improper DCE/DTE setting
1. Improper twisted pair wiring
4. AC power adapter is defective
3. Outlet is defective
2. Loose power connection
1. The AC transformer is not plugged into the Model 1060
5. Check specifications in Appendix B
4. The transmitter must be enabled by a specific "control input" pin (refer to Table 1 in Section 3.3)
3. Be sure all bit rate settings on all connected serial ports are the same
2. Set both DCE/DTE switches alike, according to the instructions in Section 3.2
1. Compare your twisted pair wiring with the diagram in Section 4.1
4. Call Patton Electronics for a replacement adapter
3. Try a different outlet
2. Make sure the AC connection is flush
1. Have another cup of coffee!

Occasional data errors

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Patton electronic 1060

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Patton electronic 1060

Be the first to ask — other owners or our team will answer.

Original document

Patton electronic 1060 manual PDF

10 pages·76 KB·Network Card·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…