Page 1 of the Patton electronic 1010A user manual — SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007
Page 1 · click to enlarge
Page 1

Part# 07M1010A-A Doc# 039011UA Revised 11/8/95

MODEL 1010A Miniature, High Speed Short Range Modem with Transformer Isolation

USER MANUAL

Patton electronic 1010A — MODEL 1010A Miniature, High Speed Short Range Modem with Transformer Isolation diagram (page 1)
Fig. 1 · MODEL 1010A Miniature, High Speed Short Range Modem…

SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007

Page 2 of the Patton electronic 1010A user manual — 1.0 WARRANTY INFORMATION
Page 2 · click to enlarge
Page 2
Patton electronic 1010A — A PPENDIX D BLOCK DIAGRAM diagram (page 2)
Fig. 2

A PPENDIX D BLOCK DIAGRAM

All warranty and non-warranty repairs must be returned freight prepaid and insured to Patton Electronics. All returns must have a Return Materials Authorization number on the outside of the shipping container. This number may be obtained from Patton Electronics Technical Service at (301) 975-1007. Packages received without an RMA number will not be accepted. Patton Electronics' technical staff is also available to answer any questions that might arise concerning the installation or use of your Model 1010A. Technical Service hours: 8AM to 5PM EST, Monday through Friday.

1.2 SERVICE

The Model 1010A generates and uses radio frequency energy, and if not installed and used properly—that is, in strict accordance with the manufacturer's instructions—may cause interference to radio and television reception. The Model 1010A has been tested and found to comply with the limits for a Class A computing device in accordance with the specifications in Subpart J of Part 15 of FCC rules, which are designed to provide reasonable protection from such interference in a commercial installation. However, there is no guarantee that interference will not occur in a particular installation. If the Model 1010A does cause interference to radio or television reception, which can be determined by disconnecting the RS-232 interface, the user is encouraged to try to correct the interference by one or more of the following measures: moving the computing equipment away from the receiver, re-orienting the receiving antenna, and/or plugging the receiving equipment into a different AC outlet (such that the computing equipment and receiver are on different branches).

1.1 RADIO AND TV INTERFERENCE

Patton Electronics warrants all Model 1010A components to be free from defects, and will—at our option—repair or replace the product should it fail within one year from the first date of shipment. This warranty is limited to defects in workmanship or materials, and does not cover customer damage, abuse or unauthorized modification. If this product fails or does not perform as warranted, your sole recourse shall be repair or replacement as described above. Under no condition shall Patton Electronics be liable for any damages incurred by the use of this product. These damages include, but are not limited to, the following: lost profits, lost savings, and incidental or consequential damages arising from the use of or inability to use this product. Patton Electronics specifically disclaims all other warranties, expressed or implied, and the installation or use of this product shall be deemed an acceptance of these terms by the user.

1.0 WARRANTY INFORMATION

Page 3 of the Patton electronic 1010A user manual — APPENDIX C RS-232C PIN CONFIGURATIONS
Page 3 · click to enlarge
Page 3

The Model 1010A also incorporates high speed avalanche diodes that intercept data line transient surges and shunt them safely to chassis ground. With surge handling capacity of 600W per wire at 1mS, the 1010A can protect itself and connected equipment from nearby lightning strikes and other surges of electromagnetic radiation.

An external DCE/DTE switch lets you connect to the serial port of either a computer/terminal (DTE) or a modem (DCE) without using a crossover cable. The Model 1010A is available with three 4 wire interface options: RJ-11, RJ-45 or terminal blocks with strain relief.

The Patton Model 1010A miniature, high speed, transformer isolated short range modem lets two asynchronous RS-232 devices communicate between buildings, over two twisted pair. Supporting asynchronous data rates to 115.2 Kbps, the Model 1010A derives the necessary power for operation from the data and control voltages on the RS-232 interface. DC transformer isolation on the line side gives the Model 1010A immunity to ground loops that would otherwise hamper between-building communications.

2.2 DESCRIPTION

2.1 FEATURES

Thank you for your purchase of this Patton Electronics product. This product has been thoroughly inspected and tested and is warranted for One Year parts and labor. If any questions or problems arise during installation or use of this product, please do not hesitate to contact Patton Electronics Technical Support at (301) 975-1007.

  • Provides surge protection of 600 Watts per wire
  • No AC power or batteries required—draws all necessary operating power from the RS-232 interface
  • Very thin case (.75") for closely spaced computer ports
  • Externally accessible DCE/DTE switch makes configuration easy
  • Loops back all handshaking signals on the RS-232 interface
  • Supports data rates to 115.2 Kbps, distances to 8.5 miles
  • Supports asynchronous RS-232 communication over 2 twisted pair
  • Immune to ground loops caused by ground potential differences
  • Transformer coupled for DC isolation between modems

2.0 GENERAL INFORMATION

1. (FG) Frame Ground 2- (TD) Transmit Data 3- (RD) Receive Data 4- (RTS) Request to Send 5- (CTS) Clear to Send 6- (DSR) Data Set Ready 7- (SG) Signal Ground 8- (DCD) Data Carrier Detect Data Term Ready (DTR) - 20

APPENDIX C RS-232C PIN CONFIGURATIONS

RS-232C INTERFACE (DCE)

Page 4 of the Patton electronic 1010A user manual — 3.0 CONFIGURATION
Page 4 · click to enlarge
Page 4

Weight: 2 oz.

HumidityUp to 95% non-condensing
Altitude0-15,000 feet
Temperature Range0-60°C (32-140°F)
Power SupplyNone required; uses power from EIA data and control signals

Connectors: DB-25 male or female on RS-232 side; RJ-11, RJ-45 or terminal block with strain relief on line side

Control Signals: DSR and DCD follow DTR from the terminal (DTE); CTS follows RTS from the terminal (DTE)

Factory Switch SettingDCE (transmits from RS-232 on pin 3)
Dimensions2.66" x 2.10" x 0.73"

Surge Protection: 600W power dissipation at 1 mS; component response time of 1 pS; installed response time of 2 µs

IsolationMinimum 1500 V RMS via custom transformers
Data Rates50 - 115.2 Kbps
InterfacesEIA RS-232, CCITT V.24
Range(See table below)
Transmission LineTwo unconditioned twisted pair 19 - 26 AWG
Transmission FormatAsynchronous, full duplex

Data Rate 115,200 0.6 0.45 0.3 57,600 2.0 1.5 1.0 38,400 2.4 1.8 1.2 19,200 2.6 2.0 1.2 9,600 4.0 2.5 1.6 4,800 5.0 3.5 2.2 2,400 6.8 4.7 3.2 1,200 8.5 5.7 3.8

Model 1010A Distance Table (miles)

APPENDIX B SPECIFICATIONS

Wire Gauge 19 24 26

Model 1010A Distance Table (miles) Data RateWire Gauge 192426 115,2000.60.450.3 57,6002.01.51.0 38,4002.41.81.2 19,2002.62.01.2 9,6004.02.51.6 4,8005.03.52.2 2,4006.84.73.2 1,2008.55.73.8

The figure below shows the location of the DCE/DTE switch on the PC board, as well as the location of the terminal block and surge suppressors.

The Model 1010A is designed to be easy to use. There are no internal jumpers or DIP switches to set, so there is no need to open the case to configure the unit (you may need to open the case for wire connection—refer to section 4.0). The only configuration necessary for operation is proper setting of the external DCE/DTE switch.

DCE/DTE Switch Surge Suppressors

3.0 CONFIGURATION

DCE DTE

DCE DTE

Transformers · Terminal Block

Page 5 of the Patton electronic 1010A user manual — 4.2 CONNECTION TO THE RS-232 INTERFACE
Page 5 · click to enlarge
Page 5

The RJ-11 and RJ-45 connectors on the Model 1010A's twisted pair interface are pre-wired for a standard TELCO wiring environment. The signal/pin relationships are shown below:

4.1.1 TWISTED PAIR CONNECTION USING RJ-11 OR RJ-45

For your convenience, the Model 1010A is available with three different twisted pair interfaces: RJ-11 jack, RJ-45 jack and terminal blocks with strain relief.

2. To function properly, the Model 1010A needs two twisted pairs of metallic wire. These pairs must be unconditioned , dry metallic wire, between 19 and 26 AWG (the higher number gauges may limit distance somewhat). Standard dial-up telephone circuits, or leased circuits that run through signal equalization equipment, are not acceptable.
1. These units work in pairs . Therefore, you must have one Model 1010A at each end of a two twisted pair interface.

The Model 1010A supports data-only communication between two RS-232 devices at distances to 8.5 miles and data rates to 115.2 Kbps. There are two essential requirements for installing the Model 1010A:

4.1 CONNECTION TO THE TWISTED PAIR INTERFACE

Once you have properly configured the DTE/DCE switch, you are ready to connect the Model 1010A to your system. This section tells you how to properly connect the Model 1010A to the twisted pair and RS-232 interfaces, and how to operate the Model 1010A.

1 GND* 1 N/C 2 RCV- 2 GND* 3 XMT+ 3 RCV- 4 XMT- 4 XMT+ 5 RCV+ 5 XMT- 6 GND 6 RCV+ 7 GND 8 N/C

RJ-11 SIGNAL RJ-45 SIGNAL

4.0 INSTALLATION

(Note: If your system requires hardware flow control, you will need the Patton Model 1012 or Model 1060 Short Range Modem. Call Patton Customer Service at 301-975-1007 for more information).

Once the Model 1010A is properly installed, it should operate transparently—as if it were a standard cable connection. Operating power is derived from the RS-232 data and control signals; there is no "ON/OFF" switch. All data signals from the RS-232 interface are passed straight through. All control signals from the RS-232 interface are looped back.

4.3 OPERATING THE MODEL 1010A

(Note: If you must use a cable to connect the Model 1010A to the RS-232 device, make sure it is a straight through cable of the shortest possible length—we recommend 6 feet or less).

Once you have configured the Model 1010A for DTE or DCE and connected the twisted pair wires correctly, all that remains is to plug the 1010A directly into the DB-25 port of the RS-232 device. After doing so, remember to insert and tighten the two captive connector screws.

4.2 CONNECTION TO THE RS-232 INTERFACE

11. Insert one captive screw through a saddle washer, then insert the captive screw with the washer on it through the hole in the DB-25 end of the case. Snap that side of the case closed. Repeat the process for the other side. This completes cable installation.
10. BEND the top half of the case as necessary to place it over the strain relief assembly. Do not snap the case together yet.
Page 6 of the Patton electronic 1010A user manual — GND † 1-----------------------6 GND †
Page 6 · click to enlarge
Page 6
9. Insert the strain relief assembly with the wire going through it into the slot in the bottom half of the modem case and set it into the recess in the case.
8. Place the 2 halves of the strain relief assembly on either side of the telephone wire and press together very lightly. Slide the assembly so that it is about 2 inches from the terminal posts and press together firmly. If your cable diameter is too small or too large for our strain relief, please contact our technical support. We have strain relief assemblies to accommodate most cable diameters.

+RCVG -XMT+ +RCVG -XMT+

If your RS-422 application requires you to connect two pairs of bare wires to the Model 1010A, you will need to open the case to access the terminal blocks. The following instructions will tell you how to open the case, connect the bare wires to the terminal blocks, and fasten the strain relief collar in place so that the wires won't pull loose.

4.1.2 TWISTED PAIR CONNECTION USING TERMINAL BLOCKS

†Connection to ground is optional

When connecting two Model 1010As, it is necessary to use a "cross over" cable. The diagram below shows how a cross over cable should be constructed for an environment where both Model 1010As use a 6-wire RJ-11 connector. Similar logic should be followed when using RJ-45 connectors or a combination of the two.

RCV- 2 4 XMT- XMT+ 3 5 RCV+ XMT- 4 2 RCV- RCV+ 5 3 XMT+ GND† 6 1 GND†

GND † 1 6 GND †

SIGNAL PIN# PIN# SIGNAL

1 2 3 4 5 6

1 2 3 4 5 6 7 8

RJ-11 Cable (4-Wire) · (continued)

Page 7 of the Patton electronic 1010A user manual — +RCVG -XMT+
Page 7 · click to enlarge
Page 7
Patton electronic 1010A — To Shield (Optional) } One Pair diagram (page 7)
Fig. 3 · To Shield (Optional) } One Pair
3. Strip back the insulation on each of the 2 twisted pair wires about .25".
2. Strip the outer insulation from the twisted pairs about one inch from the end.

Once the unit has been opened, you will be able to see the terminal blocks located at the rear of the PC board.

1. Open the unit by gently inserting a screw driver between the DB-25 connector and the lip of the plastic case (see below). You don't have to worry about breaking the plastic, but be careful not to bend the D-sub connector.
7. When you finish connecting the wires to the terminal block, the assembly should resemble the diagram below:
6. If there is a shield around the telephone cable, it may be connected to "G" on the terminal block. To avoid ground loops, we recommend connecting the shield at the computer end only. A ground wire is not necessary for proper operation of the Model 1010A.

Ultimately, you will want to construct a two pair cross over cable that makes a connection with the RS-422 device as shown below:

5. Connect the other pair of wires to RCV+ and RCV- (receive positive and negative) on the terminal block, again making careful note of which color is positive, and which color is negative.
4. Connect one pair of wires to XMT+ and XMT- (transmit positive and negative) on the terminal block, making careful note of which color is positive, and which color is negative.

XMT + RCV+ XMT - RCV - G G RCV - XMT - RCV + XMT +

To Shield (Optional) } One Pair

+RCVG -XMT+

} One Pair

Ask about the Patton electronic 1010A

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Patton electronic 1010A

Be the first to ask — other owners or our team will answer.

Original document

Patton electronic 1010A manual PDF

7 pages·218 KB·Network Card·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…