F565101p.1Operating Instructionsp.1Air Conditionerp.1CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKEp.1Thank you for purchasing Panasonic Air Conditionerp.2SAFETY PRECAUTIONSp.2Warningp.2During Installation During Installationp.2Cautionp.2During Operation During Operationp.2TABLE OF CONTENTp.2REGULATORY INFORMATIONp.3Environmental Requirements nvironmental Requirementsp.3End-of-Life Disposal End-of-Life Disposalp.3Indoor Unit Indoor Unitp.4Indicatorp.4Outdoor Unit Outdoor Unitp.4INTRO TO FILTER CLEANING ■ Aboutp.6Filter Cleaning Devicep.6AUTO FILTER CLEANINGp.7Filter Cleaning Indicatorp.7AUTO AUTOp.7AIR CONDITIONER TIMER AIR CONDITIONER TIMERp.7FORCE CLEANING FORCE CLEANINGp.7TIMER FILTER CLEANINGp.8MANUAL FILTER CLEANINGp.9CHANGE FILTER CLEANING DEFAULT SETTINGp.10Press to select OFF. 2p.10Press to select your desired fi lter cleaning setting: 4p.10AUTO, HEAT, COOL, DRYp.11HEAT - Heating Operation 2p.11Select your desired temperature. (16°C~30°C)p.11VENTILATIONp.12FAN SPEED, AIR SWINGp.13AIR SWINGp.13Press to select fan speedp.13To confi rm the setting. 3p.15CARE & MAINTENANCEp.16MOVABLE FRONT PANEL MOVABLE FRONT PANELp.16INDOOR UNITp.16MOVABLE FRONT PANEL & TOP GRILLp.16TOP GRILL TOP GRILLp.16Wipe gently. INDOOR UNIT INDOOR UNITp.16Top air fi lterp.16Super allerubuster fi lterp.16Front air fi lterp.16AIR FILTERp.17REMOVE THE FRONT AIR FILTER REMOVE THE FRONT AIR FILTERp.17SUPER ALLERU-BUSTERp.17FILTER INSTALLATIONp.17REMOVE THE TOP AIR FILTER REMOVE THE TOP AIR FILTERp.17Pull the air fi lter towards you. 3p.17REMOVE THE SUPER ALLERU-BUSTER FILTER REMOVE THE SUPER ALLERU-BUSTER FILTERp.17Detach the fi lter gently. 4p.17NON SERVICEABLE CRITERIASp.19FUNZIONAMENTO ANOMALOp.19OMSTANDIGHEDEN WAARIN U HULP MOET INROEPENp.19CRITÉRIOS SEM MANUTENÇÃOp.19ΠΕΡΙΠΤΩΣΕΙΣ ΠΟΥ ΔΕΝ ΑΝΤΙΜΕΤΩΠΙΖΟΝΤΑΙ ΑΠΟ ΤΟ ΧΡΗΣΤΗp.19КРИТЕРИИ ЗА ПОВРЕДАp.19Printed in Malaysiap.20Web Site: http://www.panasonic.co.jp/global/ F565101p.20OPSC0601-02p.20
Page 1 of the Panasonic CS-XE12EKE user manual — F565101
Page 1 · click to enlarge
Page 1

F565101

Operating Instructions

Air Conditioner

CS-XE9EKE CU-XE9EKE CS-XE12EKE CU-XE12EKE

Panasonic CS-XE12EKE — F565101 diagram (page 1)
Fig. 1

ENGLISH Before operating the unit, read these operating instructions thoroughly and keep them for future reference. 2 ~ 17 ESPAÑOL Antes de utilizar la unidad, sírvase leer atentamente estas instrucciones de funcionamiento y conservarlas como futuro elemento de consulta. 18 ~ 33 ITALIANO Prima di utilizzare l’unità si prega di leggere attentamente le istruzioni e di conservare questo opuscolo per potervi fare riferimento in futuro. 34 ~ 49 NEDERLANDS Leest u voor het gebruik de instructie en bewaar deze om later te kunnen raadplegen. 50 ~ 65 PORTUGUÊS Antes de ligar a unidade, leia cuidadosamente este manual de utilização e guarde-o para futura referência. 66 ~ 81 EΛΛΗΝΙΚΆ Προτού θέσετε τη μονάδα σε λειτουργία, διαβάστε προσεκτικά αυτές τις οδηγίες χρήσης και φυλάξτε τις για μελλοντική αναφορά. 82 ~ 97 БЪЛГАРСКИ Преди да задействате климатика, прочетете внимателно инструкциите за употреба и ги запазете за бъдещи справки. 98 ~ 113

Manufactured by: Panasonic HA Air-Conditioning (M) Sdn. Bhd. Lot 2, Persiaran Tengku Ampuan, Section 21, Shah Alam Industrial Site, 40300 Shah Alam, Selangor, Malaysia.

© 2005 Panasonic HA Air-Conditioning (M) Sdn Bhd (11969-T). All rights reserved. Unauthorized copying and distribution is a violation of law.

Page 2 of the Panasonic CS-XE12EKE user manual — TABLE OF CONTENT
Page 2 · click to enlarge
Page 2

Thank you for purchasing Panasonic Air Conditioner

SAFETY PRECAUTIONS

  • Definition

To prevent personal injury, injury to others, or property damage, please observe the following.

Warning

During Installation During Installation

Incorrect operation due to failure to follow instructions may cause harm or damage, the seriousness of which is classifi ed as below:

  • Do not install, remove and reinstall the unit by yourself; improper installation will cause leakage, electric shock or fi re. Please consult an authorized dealer or specialist for the installation work.
  • This equipment must be earthed and installed with ELCB. It may cause electrical shock or fi re in case of malfunction During Operation During Operation
  • Do not share the same power outlet with other equipment.
  • Do not modify power cords.
  • Do not use extension cords.
  • Do not operate with wet hands.
  • Do not operate or stop the unit by inserting or pulling out the power plug.
  • Do not insert your fi ngers or other objects into the indoor or outdoor unit.
  • Do not attempt to repair the unit by yourself.
  • Do not use rechargeable (Ni-Cd) batteries.
  • Keep the remote control away from infants and small children to prevent them from accidentally swallowing the batteries.
  • Insert the power plug properly.
  • Use the specifi ed supply cord.
  • If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualifi ed persons in order to avoid a hazard.
  • Remove the batteries if the unit is not going to be used for a long period of time.
  • New batteries of the same type must be inserted following the polarity stated to prevent malfunction of the remote control.

Warning

This sign warns of death

or serious injury.

Caution

This sign warns of injury

or damage to property.

  • In case of emergency or abnormal conditions (burning, unusual odour, etc), turn off the power supply and unplug.

The instructions to be followed are classifi ed by the following symbols:

Caution

During Installation During Installation

  • Ensure that the drainage pipe is connected properly. Otherwise, leakage may occur.

an action that is

PROHIBITED.

  • Do not install the unit in a potentially explosive atmosphere.

During Operation During Operation

  • Do not pull the cord to disconnect the plug.
  • Do not wash the unit with water, benzene, thinner or scouring powder.
  • Do not use for other purposes such as preservation of food.
  • Do not use any combustible equipment in front of the airfl ow outlet.
  • Do not sit or place anything on the indoor or outdoor unit.
  • Do not expose directly to cold air for a long period.
  • Switch off the power supply and unplug before cleaning or servicing.
  • Turn off the power supply and unplug if the unit is not used for a long period of time.
  • This air conditioner is equipped with a built-in surge protective device. However, in order to further protect your air conditioner from being damaged by abnormally strong lightning activity, you may want to disconnect it from the power supply. Do not touch the air conditioner during lightning, it may cause electric shock.

actions that are COMPULSORY.

  • Aerate the room regularly.
  • After long periods of use, make sure the installation rack is not damaged.

TABLE OF CONTENT

SAFETY PRECAUTIONS, REGULATORY INFORMATION 2~3 PRODUCT OVERVIEW 4~5 INTRO TO FILTER CLEANING 6 AUTO FILTER CLEANING, TIMER FILTER CLEANING 7~8 MANUAL FILTER CLEANING 9 CHANGE FILTER CLEANING DEFAULT SETTING 10 AUTO, HEAT, COOL, DRY, VENTILATION 11~12 FAN SPEED, AIR SWING 13 POWERFUL, QUIET, TIMER 14~15 CARE & MAINTENANCE 16~17

This symbol denotes · These symbols denote

Page 3 of the Panasonic CS-XE12EKE user manual — End-of-Life Disposal End-of-Life Disposal
Page 3 · click to enlarge
Page 3

REGULATORY INFORMATION

  • Operation Condition

The appliance is not intended for use by young children or the infi rm person without supervision. Young children should be supervised to ensure that they do not play with the appliance.

Use this air conditioner under the following temperature range.

Temperature (°C)Indoor *DBT*WBT COOLINGMaximum3223 Minimum1611 HEATINGMaximum30– Minimum16–

Environmental Requirements nvironmental Requirements

Battery disposal The batteries must be recycled or disposed of properly.

Temperature (°C)Outdoor *DBT*WBT COOLINGMaximum4326 Minimum-15– HEATINGMaximum2418 Minimum-15–

End-of-Life Disposal End-of-Life Disposal

*DBTDry bulb temperature *WBT: Wet bulb temperature

“Instructions for end-user” for air conditioners:

This air conditioner bears the above mark, indicating that electrical equipment should not be disposed of alongside general household waste. European Community countries (*), should have a dedicated collection system for these products. Do not try to dismantle the system yourself as this could have harmful effects on your health and on the environment as a result of incorrect waste handling. This dismantling and disposal of refrigerant, oil and other parts must be done by a qualifi ed installer in accordance with relevant local and national regulations. Air conditioners must be treated at a specialized treatment facility for re-use, recycling and recovery and should not be disposed of in the municipal waste stream. Please contact your installer, dealer or local authority for more information. Penalties may also be applicable for incorrect disposal of waste products, in accordance with national legislation.

  • This unit is still able to operate as a cooler with outdoor temperature as low as -15°C in a non-living room, such as a computer room, with a room temperature of 16°C or above, and room humidity up to 80%.
  • When the outdoor temperature drops to -15°C, compressor will be cut off and resume operation again once the temperature rises to more than -15°C.

*subject to the national law of each member state

Information on Disposal in other countries outside the European Union This symbol is only valid in the European Union. If you wish to discard this product, please contact your installer, dealer or local authority and ask for the correct method of disposal.

The illustrations in this manual are for explanation purposes only and may differ from the actual unit. It is subjected to change without notice for future improvement.

Replacement or installation of power plugs shall be performed by authorized/qualifi ed personnel only.The wires in this mains lead are coloured in accordance with the following code:

Wiring colour may vary depending on a country wiring code’s standard.

Show 9 more labels / short text on this page
Terminals wires · colours (GB Standard) · red · live · brown · black · neutral · blue · green-yellow earth green/yellow
Page 4 of the Panasonic CS-XE12EKE user manual — Indicator
Page 4 · click to enlarge
Page 4
  • About PRODUCT OVERVIEW

Note: * Movable front panel will open slightly for air intake purposes once the air conditioner operation starts. Movable front panel will remain open during air conditioner operation. It will close automatically once the air conditioner operation stops. In such a condition, do not interrupt the movable front panel movement as this may cause malfunction or unit breakdown. The above condition does not apply for fi lter cleaning.

  • To operate the unit if the remote control is misplaced or malfunctioning.
StepActionMode 1Press once.Automatic 2Press and hold until you hear one beep, then release.Force cooling 3Repeat step 2. Press and hold until you hear two beeps, then release.Normal cooling 4Repeat step 3. Press and hold until you hear three beeps, then release.Force heating

Indoor Unit Indoor Unit

Filter cleaning indication light

Super alleru buster filter

  • To turn off, press the AUTO OFF/ON button again.

Indicator

Outdoor Unit Outdoor Unit

Show 14 more labels / short text on this page
Auto OFF/ON Button · Air intake · Filter cleaning device · Movable front panel* · Air filter · Auto OFF/ON button · Air filter fastener · Airflow direction · louver · Receiver · Discharged air · Air inlet (rear) · Air inlet (side) · Air outlet
Page 5 of the Panasonic CS-XE12EKE user manual — Indoor Unit Indoor Unit
Page 5 · click to enlarge
Page 5
Panasonic CS-XE12EKE — Indoor Unit Indoor Unit diagram (page 5)
Fig. 2 · Indoor Unit Indoor Unit
  • Timer operation will be based on current time set.
  • The batteries can be used for approximately 1 year.
  • Certain fluorescent lights may interfere with signal transmission. Please consult your nearest authorized dealer.

* For normal operation, the and buttons are not in use.

  • In the event of an error, the unit will stop and the timer indicator will blink. Notes:
  • The unit may be operable (with 4 beeps) on a limited basis, depending on the error.
2. Press until you hear beep sound, then jot down the error code.
4. Turn the unit off and reveal the error code to your nearest dealer.
Page 6 of the Panasonic CS-XE12EKE user manual — Filter Cleaning Device
Page 6 · click to enlarge
Page 6

INTRO TO FILTER CLEANING ■ About

Filter cleaning function helps to:

  • Clean the filters automatically on a regular basis.
  • Avoid airflow blockage caused by dusty filter.
  • Prevent growth of mold inside the unit.
  • Improve heating/cooling effect that saves energy consumption.

Filter Cleaning Device

  • By default, filter cleaning will run automatically once the unit is turned off if the air conditioner:

- Operates continuously for at least 2 hours and above, and

- Accumulative operation time is at least 2 hours and above.

  • The filter surface is divided into rows. Each cleaning cycle will clean one row at a time. The numbers of rows to be cleaned will be based on the air conditioner’s accumulative operation time and model purchased. The following table is an example for model 1.5 HP.
Accumulative operation time (<less than)

Number of cleaning cycle (1 cycle: < 4 minutes)

< 2 hours 0

2 hours and < 6 hours 2

6 hours and < 9 hours 3

9 hours and < 12 hours 4

12 hours and < 15 hours 5

15 hours and < 18 hours 6

18 hours and < 21 hours 7

21 hours and < 24 hours 8

  • The number of cleaning cycle depends on the fan speed setting as well. The table above is an example when the fan speed setting is HI. The number of cleaning cycle will be lesser if the fan speed setting is lower.
  • You can also set the filter cleaning manually. For details, see Timer Filter Cleaning and Manual Filter Cleaning in the following pages.
  • When the fi rst air conditioner operation is initialized, fi lter cleaning will run one cycle automatically.

► This is a normal operation to make sure the fi lter cleaning device is able

to move smoothly. ► Filter cleaning will not be terminated by pressing any of the remote

control buttons. Filter cleaning will stop by itself after operates for one cycle.

Filter cleaning · Auto Filter Cleaning

Page 7 of the Panasonic CS-XE12EKE user manual — FORCE CLEANING FORCE CLEANING
Page 7 · click to enlarge
Page 7

AUTO FILTER CLEANING

  • About
  • The fi lter cleaning indicator light will move to left or right when fi lter cleaning is in progress.
  • Filter cleaning in progress will be cancelled if:

- Certain button on the remote

control are pressed.

- The air conditioner main unit’s

movable front panel is lifted up.

- There is a power failure.

Filter Cleaning Indicator

AUTO AUTO

  • Filter cleaning will run automatically after the air conditioner operation stops (air conditioner is turned off using remote control).
  • After the filter cleaning is completed, the air conditioner operation will remain off.

AIR CONDITIONER TIMER AIR CONDITIONER TIMER

  • Filter cleaning will run automatically after the air conditioner operation stops (air conditioner is turned off by the air conditioner timer).
  • After the filter cleaning is completed, the air conditioner operation will remain off.

FORCE CLEANING FORCE CLEANING

  • Once the air conditioner operation time exceeds 24 hours, the unit is forced to run filter cleaning.
  • After the filter cleaning is completed, the air conditioner operation will resume automatically.
  • Timer indicator is blinking and error code H51 is revealed on the display.

► The fi lter cleaning device is jammed because the fi lter is not installed

correctly. ► The fi lter cleaning device is malfunction.

  • Timer indicator is blinking and error code H52 is revealed on the display.

► The fi lter cleaning device is malfunction. ► Printed circuit board is malfunction.

  • Note :
  • To reveal the error code, please refer to Product Overview’s troubleshooting-error code checking.
  • The condition above does not affect the unit’s operation.
  • In case of malfunction, please consult your nearest authorized dealer.

Filter cleaning · Auto Filter Cleaning

Page 8 of the Panasonic CS-XE12EKE user manual — TIMER FILTER CLEANING
Page 8 · click to enlarge
Page 8

TIMER FILTER CLEANING

  • About
  • Filter cleaning timer can be set to run at a specified time daily, given that the air conditioner accumulative operation time is at least 30 minutes and above.
Panasonic CS-XE12EKE — TIMER FILTER CLEANING diagram (page 8)
Fig. 3
Panasonic CS-XE12EKE — TIMER FILTER CLEANING diagram (page 8)
Fig. 4
  • Filter cleaning timer overrides air-conditioner’s timer in any given setting.
Panasonic CS-XE12EKE — TIMER FILTER CLEANING diagram (page 8)
Fig. 5
  • Once filter cleaning timer starts, air conditioner operation will stop. After the filter cleaning is completed, the air conditioner operation will resume automatically.
Panasonic CS-XE12EKE — TIMER FILTER CLEANING diagram (page 8)
Fig. 6

Press to select your desired time.

Press to set cleaning timer.

  • To reveal filter cleaning timer start time:

Press .

Panasonic CS-XE12EKE — TIMER FILTER CLEANING diagram (page 8)
Fig. 7
  • To restore the filter cleaning timer after power is resumed:
Panasonic CS-XE12EKE — TIMER FILTER CLEANING diagram (page 8)
Fig. 8

Press , then press .

  • To return to normal display / exit:

Press or close the remote control cover.

Panasonic CS-XE12EKE — TIMER FILTER CLEANING diagram (page 8)
Fig. 9
  • Set the fi lter cleaning timer to run at an appropriate time to avoid any interruption during normal operation.

2 Press to confi rm the setting.

Press to turn on cleaning timer. ON is shown on the display.

is shown on the display.

  • To cancel fi lter cleaning timer, press , then press .

Timer Filter Cleaning

Page 9 of the Panasonic CS-XE12EKE user manual — MANUAL FILTER CLEANING
Page 9 · click to enlarge
Page 9

MANUAL FILTER CLEANING

  • About
  • Press once to run a comprehensive fi lter cleaning.
  • A comprehensive fi lter cleaning may take less than an hour to complete.
Panasonic CS-XE12EKE — MANUAL FILTER CLEANING diagram (page 9)
Fig. 10
  • When is pressed, this operation has the highest priority over other operation modes. The air conditioner operation will stop. After the fi lter cleaning is completed, the air conditioner operation will resume automatically.

Press to clean the fi lter manually.

  • After extended non-use, it is recommended to manually run fi lter cleaning before air conditioner operation is initialized.
  • Press to cancel manual fi lter cleaning.
  • The fi lter cleaning device stops half way in the middle of the main unit.

► To return the fi lter cleaning device to the original position, press and

hold for more than 5 seconds. ► To change the fi lter cleaning device from right side (original position) to

left side, press and hold for more than 5 seconds, then press .

Manual Filter Cleaning

Page 10 of the Panasonic CS-XE12EKE user manual — Press to select your desired fi lter cleaning setting: 4
Page 10 · click to enlarge
Page 10

CHANGE FILTER CLEANING DEFAULT SETTING

  • Setting
  • To disable the fi lter cleaning permanently, follow steps 1 to 3 as shown below.
  • As a default setting, fi lter cleaning will run automatically once the air conditioner unit is turned off.

Press and hold until you hear 3 beeps (about 11 seconds). 1 Press once. You will hear 1 beep.* 2

Press and hold for more than 20 seconds. ON will blink on the display.*

Press to select OFF. 2

Panasonic CS-XE12EKE — Press to select OFF. 2 diagram (page 10)
Fig. 11 · Press to select OFF. 2
Panasonic CS-XE12EKE — Press to select OFF. 2 diagram (page 10)
Fig. 12 · Press to select OFF. 2
Panasonic CS-XE12EKE — Press to select OFF. 2 diagram (page 10)
Fig. 13 · Press to select OFF. 2

Auto OFF/ ON button. Press 3 times until you hear 3 continuous beeps.* 3

Press to select your desired fi lter cleaning setting: 4

When you hear Setting

  • 1 beep
  • Filter cleaning will run automatically after the air conditioner operation stops (air conditioner is turned off using remote control).
  • After the fi lter cleaning is completed, the air conditioner operation will remain off.
  • 2 beeps **
  • Filter cleaning will run automatically before the air conditioner operation starts (air conditioner is either turned on using remote control or turned on by the air conditioner timer).
  • After the fi lter cleaning is completed, the air conditioner operation will start automatically.
  • 3 beeps **
  • Filter cleaning will run automatically before the air conditioner operation starts (air conditioner is turned on using remote control).
  • After the fi lter cleaning is completed, the air conditioner operation will start automatically.

Press to confi rm the setting. CLEANING will disappears from the display.

  • Filter cleaning will run automatically after the air conditioner operation stops (air conditioner is either turned off using remote control or turned off by the air conditioner timer).
  • After the fi lter cleaning is completed, the air conditioner operation will remain off. * Use a sharp end object to press this button. ** The setting is valid only if the following conditions are fulfi lled: 1. The air conditioner is turned off for at least 3 minutes. 2. The air conditioner has operated continuously for at least 2 hours in previous operation.
  • Auto and timer fi lter cleaning are no longer valid.
  • Select ON in step 2 above to enable fi lter cleaning.
  • Manual fi lter cleaning is operable

by pressing . For detail, see manual fi lter cleaning page.

Disable Filter Cleaning · 1 long beep · (default setting)

Page 11 of the Panasonic CS-XE12EKE user manual — Select your desired temperature. (16°C~30°C)
Page 11 · click to enlarge
Page 11

AUTO, HEAT, COOL, DRY

  • Operation Details

AUTO - Automatic Operation

  • Unit selects the operation mode according to temperature setting, outdoor and room temperature.
Panasonic CS-XE12EKE — AUTO, HEAT, COOL, DRY diagram (page 11)
Fig. 14
Panasonic CS-XE12EKE — AUTO, HEAT, COOL, DRY diagram (page 11)
Fig. 15
  • The power indicator blinks during operation.
  • Operation mode is reselected every 30 minutes.
Panasonic CS-XE12EKE — AUTO, HEAT, COOL, DRY diagram (page 11)
Fig. 16

HEAT - Heating Operation 2

  • In heating mode, it takes a while for the unit to warm up. The power indicator blinks during this operation.
Panasonic CS-XE12EKE — HEAT - Heating Operation 2 diagram (page 11)
Fig. 17 · HEAT - Heating Operation 2

Select your desired temperature. (16°C~30°C)

Select your desired operation.

COOL - Cooling Operation

  • Enjoy cool air at your desired temperature.
Panasonic CS-XE12EKE — Select your desired temperature. (16°C~30°C) diagram (page 11)
Fig. 18 · Select your desired temperature. (16°C~30°C)

DRY - Soft Dry Operation

  • Keeps your environment dehumidifi ed by running a very gentle cooling operation.
  • During soft dry operation, the indoor fan operates at low fan speed.
Panasonic CS-XE12EKE — Select your desired temperature. (16°C~30°C) diagram (page 11)
Fig. 19 · Select your desired temperature. (16°C~30°C)
Panasonic CS-XE12EKE — Select your desired temperature. (16°C~30°C) diagram (page 11)
Fig. 20 · Select your desired temperature. (16°C~30°C)
  • A temperature setting 1°C higher in cooling operation or 2°C lower in heating operation than the desired temperature equates to a 10% power saving.
  • , and operations are available in all modes.
  • Press to stop the operation.
  • Mist emerges from indoor unit. ► Condensation effect due to cooling process.
  • Heating/cooling operation does not work. ► Ensure temperature is set correctly. ► Make sure windows and doors are closed. ► Make sure inlet and outlet vents are cleared.
  • Water fl owing sound during operations. ► Cause by refrigerant fl ow inside the unit.
Page 12 of the Panasonic CS-XE12EKE user manual — VENTILATION
Page 12 · click to enlarge
Page 12

VENTILATION

  • Operation Details
  • To aerate the room.
  • As a default setting, ventilation will be turned on automatically once the air conditioner operation starts.
VENTILATIONSimultaneous
  • Operates simultaneously with Auto/ Cooling/Heating/Drying operation.
  • Press repeatedly to select your desired ventilation setting. Auto/Cooling/Heating/Drying operation remains as normal regardless of ventilation setting.

Select your desired ventilation setting.

  • When is pressed, all of the air conditioner operations are turned off.
VENTILATIONIndependent
  • Ventilation operates independently.
  • Ventilation can be turned on when the air conditioner is in nonoperation mode.
  • Fan speed in this setting remains as AUTO.
  • Press to turn off the ventilation operation.
  • Timer indicator is blinking and error code H50 is revealed on the display.

► Ventilation fan motor may be locked due to piles of dust accumulated in

the ventilation area and fails to discharge. ► Printed circuit board is malfunction. ► Ventilation fan motor is malfunction.

  • Note :
  • To reveal the error code, please refer to Product Overview’s troubleshooting-error code checking.
  • The condition above does not affect the unit’s operation.
  • In case of malfunction, please consult your nearest authorized dealer.
Show 5 more labels / short text on this page
Operation · Low Ventilation · No Ventilation · Auto Ventilation · Operation
Page 13 of the Panasonic CS-XE12EKE user manual — Press to select fan speed
Page 13 · click to enlarge
Page 13

FAN SPEED, AIR SWING

  • Operations Details
  • There are 5 fan speeds, as well as automatic*. * For automatic fan speed, the speed of the indoor fan is automatically adjusted according to the operation.

AIR SWING

  • Keeps the room ventilated.
  • There are 5 options for vertical/ horizontal airfl ow direction.
  • Do not adjust the vertical and horizontal louvers by hand.

Press to select fan speed

  • If automatic vertical airfl ow direction has been set, the louvers swing up and down automatically.
  • For HEATING operation, the air blows horizontally for a while, then starts to blow downwards.
  • If automatic horizontal airfl ow direction has been set, the louvers swing left and right automatically.
  • For HEATING operation, the airfl ow louvers start to swing left/right after the temperature rises.

Adjust the airfl ow direction louver.

  • The room has a peculiar odour. ► This may be a damp smell emitted by the wall, carpet, furniture or

clothing.

  • Indoor fan stops occasionally during automatic fan speed setting.

► This helps to remove the surrounding odours.

  • Indoor fan stops occasionally during heating operation.

► To avoid unintended cooling effect.

Page 14 of the Panasonic CS-XE12EKE user manual — FAN SPEED, AIR SWING
Page 14 · click to enlarge
Page 14
Panasonic CS-XE12EKE — FAN SPEED, AIR SWING diagram (page 14)
Fig. 21
  • To reduce power consumption during cooling operation, close the curtains to prevent the sunlight and heat from coming in.
  • and operations are not able to operate at the same time.
  • and operations could be cancelled by pressing the respective button again.
  • Noisy during operation. ► The unit may have been installed at an incline, or the movable front
  • Operation is delayed a few minutes after restart. ► The delay is a protection to the unit’s compressor.
  • Outdoor unit emits water/steam. ► Condensation or evaporation occurs on pipes.
Page 15 of the Panasonic CS-XE12EKE user manual — To confi rm the setting. 3
Page 15 · click to enlarge
Page 15
  • Operation Details TIMER
  • The timer allows you to turn the air conditioner on or off automatically.
  • The unit may start in preliminary operation before the actual set time when ON timer has been set.
  • The set timer repeats daily once set.
  • If there is a power failure, you can restore the previous setting (once power is resumed) by pressing the

To select ON or OFF timer. 1 To select your desired time.

button.

  • If the timer is cancelled, press to restore the previous setting.
  • Hint
  • To dim the indicator display:
Panasonic CS-XE12EKE — To confi rm the setting. 3 diagram (page 15)
Fig. 22 · To confi rm the setting. 3

Press and hold for 5 seconds. To cancel, press the again for 5 seconds.

To confi rm the setting. 3

  • The timer is valid only when the clock is set correctly.
  • You can set your preferred time for ON and OFF timers. The unit will turn on or off automatically.
  • To cancel ON or OFF timer, press or , then press
  • Timer indicator always on. ► The timer setting repeats daily once set.
  • Power indicator blinks before the unit is switched on. ► This is a preliminary step in preparation for the operation when the ON

timer has been set.

  • Remote control does not work. ► The batteries are inserted incorrectly or need replacing.
  • The unit does not work. ► The circuit breaker is tripped or the timer is set incorrectly.
Page 16 of the Panasonic CS-XE12EKE user manual — Top air fi lter
Page 16 · click to enlarge
Page 16

CARE & MAINTENANCE

  • Washing Instructions
  • Do not use benzene, thinner, bleach or scouring powder.

Switch off the power supply witch off the power supply before cleaning before cleaning

  • Use only soaps ( ≃ pH7) or neutral household detergent .
  • Do not use water hotter than 40°C.

MOVABLE FRONT PANEL MOVABLE FRONT PANEL

INDOOR UNIT

  • Wipe the unit gently with a soft, dry cloth.

Raise and pull to remove. Wash gently and dry.

MOVABLE FRONT PANEL & TOP GRILL

  • Do not remove the movable part from the front panel.
  • Soak cloth/sponge in lukewarm water with detergent. Squeeze it dry and wipe the panels. Repeat same step again, but this time soak cloth in lukewarm water without any detergent.
  • Do not dry the parts with a hair dryer, a stove, or under direct sunlight.
  • Dry the parts under the shades.

TOP GRILL TOP GRILL

Push up and pull to remove. Wash gently and dry.

  • Please consult your nearest authorized dealer for seasonal inspection.

Wipe gently. INDOOR UNIT INDOOR UNIT

Top air fi lter

Super allerubuster fi lter

Front air fi lter

  • For extended non-use
  • Activate heating for 2~3 hours to thoroughly dry the unit.
  • Turn off the power supply and unplug.
  • Remove the remote control batteries.
Page 17 of the Panasonic CS-XE12EKE user manual — Detach the fi lter gently. 4
Page 17 · click to enlarge
Page 17

CARE & MAINTENANCE

  • About

Switch off the power supply witch off the power supply before cleaning before cleaning

AIR FILTER

  • Wash any dusty fi lter whenever necessary.
  • Wash/rinse the fi lter gently with water to avoid damage to the unit surface.

REMOVE THE FRONT AIR FILTER REMOVE THE FRONT AIR FILTER

  • Replace any damage fi lters.

SUPER ALLERU-BUSTER

Push upwards to unlock the air fi lter fastener.

  • Vacuum the fi lter whenever necessary.
  • Replace the fi lter every 10 years or purchase the replacement fi lter if it is damaged.
Part noCZ-SA15P

FILTER INSTALLATION

  • To make sure the front air fi lter is inserted correctly: 1. Press both hollow parts until the projections are clicked. 2. Push downwards to lock the air fi lter fastener.

Press both hollow parts with fi ngers and pull out the air fi lter. 2

REMOVE THE TOP AIR FILTER REMOVE THE TOP AIR FILTER

Pull the air fi lter towards you. 3

  • To make sure the fi lter cleaning device is able to move smoothly:

REMOVE THE SUPER ALLERU-BUSTER FILTER REMOVE THE SUPER ALLERU-BUSTER FILTER

Press and hold for 10 seconds.

Detach the fi lter gently. 4

  • To reinstall the fi lter after cleaning is completed, repeats the illustration steps in a backward order, from step 4 to step 1.
  • Hints
  • For best performance, it is recommended to install the air conditioner in a room away from the kitchen.
  • Air conditioner installed near a kitchen is more likely to run a risk of damaging the air conditioner fi lter caused by oily air and dust. A fi lter exposed to excessive oily air cannot be cleaned thoroughly with auto fi lter cleaning.

Projections · Air filter fastener

Page 19 of the Panasonic CS-XE12EKE user manual — КРИТЕРИИ ЗА ПОВРЕДА
Page 19 · click to enlarge
Page 19

NON SERVICEABLE CRITERIAS

TURN OFF POWER SUPPLY and CALL Authorized Distributor under the following conditions:

  • Abnormal noise during operation.
  • Circuit breaker switches off frequently.
  • Water/foreign particles have entered the Remote Control.
  • Power cord becomes unnaturally warm.
  • Water leak from Indoor unit.
  • Switches or buttons are not functioning properly.

NO UTILICE LA UNIDAD SI...

  • Si se dan las siguientes circunstancias, CORTE LA ALIMENTACIÓN y LLAME al distribuidor autorizado
  • Si escucha ruidos extraños durante el funcionamiento
  • Si el interruptor del circuito salta frecuentemente
  • Si entra agua o elementos extraños en el mando a distancia
  • Si el cable de alimentación y el enchufe se recalientan
  • Si hay escapes de agua de la unidad interior
  • Los interruptores o los botones no funcionan correctamente

FUNZIONAMENTO ANOMALO

Se si verifi ca una delle seguenti condizioni, spegnere immediatamente l’interruttore generale e chiamare il rivenditore autorizzato:

  • Durante il funzionamento si sentono rumori anomali.
  • L’interruttore salvavita scatta frequentemente.
  • Penetrazione di acqua o di corpi estranei nel telecomando.
  • Il cavo di alimentazione su surriscalda in modo
  • L’unità interna perde acqua. anomalo.
  • Funzionamento anomalo di interruttori o pulsanti.

OMSTANDIGHEDEN WAARIN U HULP MOET INROEPEN

SCHAKEL DE STROOMTOEVOER UIT en RAADPLEEG een erkend verdeler onder de volgende omstandigheden:

  • Een abnormaal lawaai tijdens de werking.
  • De zekering springt regelmatig uit.
  • Water of vreemde deeltjes zijn in de afstandsbediening
  • De stroomdraad wordt onnatuurlijk warm. binnengedrongen.
  • De schakelaars of knoppen werken niet zoals het hoort.
  • Er lekt water uit de binneneenheid.

CRITÉRIOS SEM MANUTENÇÃO

DESLIGUE O SISTEMA DE ALIMENTAÇÃO e CONTACTE o Distribuidor Autorizado nas seguintes condições:

  • Ruído anormal durante o funcionamento.
  • Os interruptores do disjuntor desligam-se
  • Água/partículas estranhas entraram no controlo remoto. frequentemente.
  • Fuga de água da unidade interior.
  • O fi o distribuidor de corrente aquece de forma anormal.
  • Os interruptores ou botões não estão a funcionar devidamente.

ΠΕΡΙΠΤΩΣΕΙΣ ΠΟΥ ΔΕΝ ΑΝΤΙΜΕΤΩΠΙΖΟΝΤΑΙ ΑΠΟ ΤΟ ΧΡΗΣΤΗ

ΔΙΑΚΟΨΤΕ ΤΗΝ ΠΑΡΟΧΗ ΡΕΥΜΑΤΟΣ και ΚΑΛΕΣΤΕ κάποιο εξουσιοδοτημένο κατάστημα στις παρακάτω περιπτώσεις:

  • Θόρυβος κατά τη λειτουργία .
  • Συχνή πτώση του ασφαλειοδιακόπτη .
  • Είσοδος νερού / σωματιδίων στο τηλεχειριστήριο .
  • Αποσυνδέστε την παροχή ρεύματος .
  • Διαρροή νερού από την εσωτερική μονάδα .
  • Οι διακόπτες ή τα πλήκτρα δε λειτουργούν σωστά .

КРИТЕРИИ ЗА ПОВРЕДА

ИЗКЛЮЧЕТЕ ЗАХРАНВАНЕТО и се ОБАДЕТЕ на оторизирания дистрибутор при следните условия:

  • Необичаен звук по време на работа .
  • Прекъсвачът на ел . верига се изключва често .
  • Вода / чужди частици са попаднали в дистанционното управление .
  • Захранващият кабел се загрява необичайно .
  • Изтича вода от Вътрешния уред .
  • Копчетата или бутоните не функционират правилно .
Page 20 of the Panasonic CS-XE12EKE user manual — Printed in Malaysia
Page 20 · click to enlarge
Page 20

Matsushita Electric Industrial Co., Ltd.

Printed in Malaysia

Web Site: http://www.panasonic.co.jp/global/ F565101

OPSC0601-02

Ask about the Panasonic CS-XE12EKE

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Panasonic CS-XE12EKE

Be the first to ask — other owners or our team will answer.

Original document

Panasonic CS-XE12EKE manual PDF

20 pages·4.1 MB·Air Conditioner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…