EN
Panamax logo
Official user manual

Panamax Surge Protection Module (MODCAT5)

2 pages·322 KB·Surge Protector·PDF·ENDEFRITNLJA
Panamax Surge Protection Module (MODCAT5)
Table of Contents 69 sections INSTRUCTIONS FOR PANAMAX SIGNAL LINE PROTECTION MODULES - PREMIUM SERIES · Model: MOD-AT2 (Secondary Protector) · LINE IN RJ-45 · EQUIP · … ShowHide
Page 1 of the Panamax Surge Protection Module (MODCAT5) user manual — 800-472-5555 www.panamax.com
Page 1 · click to enlarge
Page 1

INSTRUCTIONS FOR PANAMAX SIGNAL LINE PROTECTION MODULES - PREMIUM SERIES

Model: MOD-AT2 (Secondary Protector)

LINE IN RJ-45

EQUIP

OUT RJ-45

MOD-AT8110

LINE IN RJ-45

EQUIP

OUT RJ-45

MOD-AT4

MOD-DT4

LINE IN S110D

LINE IN RJ-14

EQUIP

OUT RJ-14

EQUIP

OUT S110D

LINE IN S110D

EQUIP

LINE IN S110D

LINE IN RJ-14

EQUIP

OUT RJ-14

EQUIP

OUT S110D

MOD-AT2

LINE IN RJ-11

EQUIP

OUT S110D

LINE IN RJ-11

EQUIP

WIRING DIAGRAM AND SPECIFICATIONS

OUT LINE IN

EQUIP

OUT RJ-11

EQUIP

OUT RJ-11

MOD-AT2 For Analog Telephone Lines

LINE IN RJ-11

EQUIP

OUT RJ-11

LINE IN RJ-11

OUT RJ-11

MOD-AT2

OUT LINE IN

EQUIP

MOD-AT2 MOD-AT4 MOD-AT8110 MOD-DT4

  • 4 Wires (1 RJ-14) Protected
  • 260 Volt Clamping
  • Auto-resetting PTC's

LINE IN RJ-11 SAT / CATV

MOD-DBSTV

MOD-SPKP

MOD-CAT5

EQUIP

OUT RJ-11

OUTSIDE LINES

RECEIVER

The MOD-AT2 module is designed to protect standard phone lines connected to computer modems, telephones, pay-per-view ports, etc. It will also protect DSL lines (ADSL, G.Lite) going into the DSL modem. The MOD-AT2 module will protect a single phone line using an RJ-11 (2 wire) cord or a dual phone line using an RJ-14 (4 wire) cord.

1. Connect the telephone line to the LINE jack on the module.

MOD-UTP

OUT LINE IN

EQUIP.

SAT / CATV

SAT / CATV

2. Use a modular cord to connect the EQUIP modular jack to the equipment to be protected.

MOD-UTP MOD-CAT5 MOD-DBSTV MOD-SPKP

These modules are approved accessories for use with compatible Panamax AC base units. Compatible base units include the following:

DISCONTINUED PRODUCTS

CURRENT PRODUCTS

Model: MOD-AT4 (Secondary Protector)

AC Base Units

AC Base Units

WIRING DIAGRAM AND SPECIFICATIONS

M8HT-PRO

PM8-EX

M4-EX

M8C-EX

M4 M4T M4L

M8 M8T M8C

M8KSU M8COM M8KSU

M8-HT

PM8T-EX

M4T-EX

M8DBS-EX

LINE IN RJ-45

EQUIP

OUT RJ-45

PM8-HT

PM8C-EX

M8-EX

M8C-Pro

MOD-AT4

PM8DBS-EX

M8C-EX

M8HC-Pro

LINE IN RJ-14

EQUIP

1. 8 1 - 4 1 - 4 1 - 4

LINE IN S110D

OUT RJ-14

EQUIP

1. 8 1 - 4 1 - 4 1 - 4

OUT S110D

When properly installed, the base unit’s Connected Equipment Protection Policy remains valid. All modules include a small rectangular bracket and mounting screws. This bracket replaces the small triangular wall-mount bracket that comes with the models listed in the CURRENT PRODUCTS above.

LINE IN RJ-11

EQUIP

OUT RJ-11

LINE IN RJ-11

EQUIP

OUT RJ-11

  • Lines
  • 4 Pairs (8 wires) Protected
  • 260 Volt Clamping
  • Straight-Through Pinout

Installation Instructions

The MOD-AT4 module is designed to pro- tect standard phone lines and DSL (ADSL, G.Lite) lines. Multiple input & output jacks provide complete installation flexibility. The following diagram shows how the jacks/wires are interconnected. Different cables/connections can be split or com- bined to accommodate a variety of installa- tions. For example:

  • Two RJ14 (dual-line) cords connected to the LINE side (upper 2 jacks) can be split to four RJ11 (single-line) cords on the EQUIP side .
1. Mount the rectangular bracket to the back of the AC base unit with the #8-32 x 5/16” machine screws. Note: The brass ground connector must be used with the bracket in order to bond the module ground to the base unit’s ground.

Module

  • Four RJ11 (single-line) cords connected to the LINE side can be combined into a single RJ45 (8 wire) cord (upper jack) on the EQUIP side.
2. Mount the signal line module to the bracket (screws provided with the module).

Bracket

  • Incoming lines can be punched-down on the 110 jack on the LINE side and four RJ11 (single-line) cords will connect from the EQUIP side to the equipment.
3. Optional – The assembled base unit and module(s) may be wall mounted if desired.
4. Connect the wiring to the signal line module as shown in the appropriate following section.

Model: MOD-AT8110 (Secondary Protector)

All telephone input/output connections will be labeled with LINE and EQUIP.

AC Base Unit

WIRING DIAGRAM AND SPECIFICATIONS

LINE IN

EQUIP.

MOD-AT8110

OUT

It is very important to connect telephone signal lines properly.

LINE IN S110D

EQUIP

OUT S110D

An easy access PULL OUT card is included on the back of each module for wiring diagrams and specifications.

110 IDC 110 IDC

  • MOD-AT8110 For Analog Telephone Lines
  • 16 Wires (two 110 punch-downs) Protected
  • 260 Volt Clamping
  • Auto-resetting PTC's

There are no designated input/output connections on coaxial protection modules. These are bi-directional modules in both transmission fre- quency and voltage.

SAT / CATV

The MOD-AT8110 module is designed to protect up to 8 standard phone lines using 110 punchdown connectors on both the input LINE and output EQUIP.

cable to the LINE IN punchdown block on the module.

2. Punch down another cable to the EQUIP OUT punchdown block on the module and connect to the phone equipment.
1. Cut the cable from the primary protector to the correct length and punch down the

800-472-5555 www.panamax.com

Show 34 more labels / short text on this page
Pull Out · Pull Out · Pull Out · Pull Out · Pull Out · Pull Out Card · Pull Out · Pull Out · Pull Out · Bl Bl · Or Or · Pull Out · Gr Gr · Br Br · MOD-AT4 For Analog · Telephone · Pull Out Card · Ground Connector · Ground Connector · Ground Connector · Blue · Blue · Orange · Orange · Green · Green · Brown · Brown · Pull Out · Blue Blue · Orange Orange · Green Green · Brown Brown · Pull Out
Page 2 of the Panamax Surge Protection Module (MODCAT5) user manual — INS0769 REV .D 06/07
Page 2 · click to enlarge
Page 2

INSTRUCTIONS FOR PANAMAX SIGNAL LINE PROTECTION MODULES - PREMIUM SERIES

Model: MOD-DT4 (Secondary Protector) Model: MOD-DBSTV (Secondary Protector)

WIRING DIAGRAM AND SPECIFICATIONS

WIRING DIAGRAM AND SPECIFICATIONS

PINS 3, 4

LINE IN RJ-45

EQUIP

LINE IN RJ-11 SAT / CATV

Coax protectors are bi-directional. There is no "IN" or "OUT".

LINE EQUIP

OUT RJ-45

MOD-DBSTV

MOD-DT4

EQUIP

LINE IN RJ-14

EQUIP

OUT RJ-14

EQUIP

1. 4 1 - 4 1 - 8

OUT RJ-11

SAT 1

MOD-DBSTV For Digital Satellite & CATV Systems

LINE IN S110D

OUT S110D

3 Sat/CATV Lines Protected

RJ-11

LINE IN RJ-11

EQUIP

75 Volt Clamping <1 0.5dB 0 MHz to 2.2 GHz

OUT RJ-11

1. 4 1 - 4 1 - 4

SAT / CATV

SAT / CATV

1 Phone Line Protected

LINE IN RJ-11

EQUIP

OUT RJ-11

SAT 2 CATV

  • MOD-DT4 For Digital Telephone Lines
  • 4 Pairs (8 wires) Protected
  • 70 Volt Clamping
  • Straight-Through Pinout

The MOD-DT4 module is designed to pro- tect Digital Station (DS) Set phone lines. Station Set lines that leave the building are a pathway for surges (backdoor) to enter the phone system. This is why the lines FROM the Station Sets are connected to the LINE side of the module and the EQUIP side of the module is connected to the phone sys- tem. Multiple input & output jacks provide complete installation flexibility. The follow- ing diagram shows how the jacks/wires are interconnected. Different cables/connec- tions can be split or combined to accommo- date a variety of installations.

For example: • Station Set lines from the phone system can be punched-down on the 110 jack on the EQUIP side and four RJ11 (2 wire) cords will connect from the LINE side to the Station Sets.

The MOD-DBSTV module provides protec- tion for 3 SAT / CABLE / ANT and 1 tele- phone line.

1. Connect the Satellite LNB or Cable TV coax cable from the wall/floor jack to one of the “F” connectors labled SAT/CATV on the module
  • Station Set lines from the phone system can be punched-down on the 110 jack on the EQUIP side and two RJ14 (4 wire) cords will connect from the LINE side (upper 2 jacks) to the Station Sets.
2. Use a coax patch cord to connect the other SAT/CATV labeled modular “F” connector to the equipment to be protected.
3. Repeat steps 1 and 2 for up to 2 additional satellite or cable TV lines.
4. Connect the telephone line to the LINE jack on the module.

Model: MOD-UTP (Isolated Loop Circuit Protector)

5. Use a modular cord to connect the EQUIP modular jack to the equipment to be protected.

WIRING DIAGRAM AND SPECIFICATIONS

MOD-UTP

MOD-UTP For 10/100 Base-T Ethernet

OUT LINE IN

EQUIP.

  • 4 Wires (Pins 1, 2, 3, 6) Protected
  • 7 Volt Clamping

Model: MOD-SPKP (Isolated Loop Circuit Protector)

WIRING DIAGRAM AND SPECIFICATIONS

Use modules bonding-strap connection to attach ground, shield or drain wires.

The MOD-UTP module is designed to pro- tect networked computer equipment. It will protect one Ethernet 10/100 Base-T, Token Ring, Arcnet, or AppleTalk network line.

2. Use a modular cord to connect the EQUIP modular jack to the equipment to be protected.

MOD-SPKP

OUTSIDE LINES

RECEIVER

Please note: The protection circuitry will not work if the signal lines are reversed.

1. Connect the network line from wall/floor jack to the LINE jack on the module.

MOD-SPKP For Outdoor Speaker, Keypad, Control & Security Wires

  • 8 Wires Protected, 47 Volt Clamping
  • 7 Amp (per wire) Capacity,
  • 12 AWG Max. Wire Size

Model: MOD-CAT5 (Isolated Loop Circuit Protector)

The MOD-SPKP module is designed to protect outdoor speaker, keypad, control and security wires (8 wires or 4 pairs). Equipment lines that lead outside the build- ing are pathways for surges (sometimes called backdoor surges) to enter the equip- ment. This is why the lines FROM the out- door equipment is connected to the LINE side of the module and the EQUIP side of the module is connected to the equipment.

2. Connect the wires from the outdoor equipment to terminals on the LINE side of the module.

SPECIFICATIONS

MOD-CAT5 For 10/100/1000 Base-T Ethernet

MOD-CAT5

3. Connect the wires from the EQUIP side of the module to the equipment.
  • 8 Wires (4 Pairs) Protected
  • 19 Volt Clamping
  • CAT5E Compliant
4. If the cable has a shield or drain wire, connect it to the modules bonding-strap connection located on the upper right portion of the module. If more than one module is connected to the AC base unit, placing this module at the top may allow for easier connection of shield or drain wires.

The MOD-CAT5 module is designed for high-speed data applications-networks including CAT 5, fast Ethernet, ATM, and other high-speed active transport devices.

1. Connect the CAT 5 cable connected on either side on the module to the wall/floor jack and then to the equipment to be protected. There is no “IN” or “OUT”. MOD-CAT5 is bi-directional.
1. Strip the ends of the individual wires about 1/4 inch. The screw clamp terminals will work with a range of wire sizes (up to 12AWG). Spade lugs are not required, but may be used.

INS0769 REV .D 06/07

Show 10 more labels / short text on this page
Bl Bl · Or Or · Pull Out · Gr Gr · Br Br · Pull Out Card · 260 Volt Clamping · Pull Out · Pull Out · Pull Out

Ask about the Panamax Surge Protection Module (MODCAT5)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Panamax Surge Protection Module (MODCAT5)

Be the first to ask — other owners or our team will answer.

Original document

Panamax Surge Protection Module (MODCAT5) manual PDF

2 pages·322 KB·Surge Protector·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…