NN Northbank, Irlam Manchester M44 5BD United Kingdom
NN TEL: (203) 359-1660NN FAX: (203) 359-7700
NN TEL: (514) 856-6928NN FAX: (514) 856-6886
ISO 9002 CertifiedN River Bend Technology Centre
ISO 9001 CertifiedN Stamford CT 06907-0047
NN Laval (Quebec) H7L 5A1
It is the policy of OMEGA to comply with all worldwide safety and EMC/EMI regulations that apply.
OMEGA is constantly pursuing certification of its products to the European New Approach
The information contained in this document is believed to be correct, but OMEGA Engineering,
Inc. accepts no liability for any errors it contains, and reserves the right to alter specifications
12450ML-99 Rev.F MQS1297/0202
This device is marked with the international caution symbol. It is important to read the
Setup Guide before installing or commissioning this device as it contains important
OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and
workmanship for a period of 13 months from date of purchase. OMEGA Warranty adds an
additional one (1) month grace period to the normal one (1) year product warranty to cover
handling and shipping time. This ensures that OMEGA’s customers receive maximum
If the unit should malfunction, it must be returned to the factory for evaluation. OMEGA’s
Customer Service Department will issue an Authorized Return (AR) number immediately upon
phone or written request. Upon examination by OMEGA, if the unit is found to be defective it will
be repaired or replaced at no charge. OMEGA'S WARRANTY does not apply to defects resulting
from any action of the purchaser, including but not limited to mishandling, improper interfacing,
operation outside of design limits, improper repair, or unauthorized modification. This
WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence
of being damaged as a result of excessive corrosion; or current, heat, moisture or vibration;
improper specification; misapplication; misuse or other operating conditions outside of OMEGA’s
control. Components which wear are not warranted, including but not limited to contact points,
OMEGA is pleased to offer suggestions on the use of its various products. However, OMEGA
neither assumes responsibility for any omissions or errors nor assumes liability for any damages
that result from the use if its products in accordance with information provided by OMEGA, either
verbal or written. OMEGA warrants only that the parts manufactured by it will be as specified and
free of defects. OMEGA MAKES NO OTHER WARRANTIES OR REPRESENTATIONS OF ANY
KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED
WARRANTIES INCLUDING ANY WARRANTY OF MERCHANTABILITY AND FITNESS FOR A
additionally, purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or
Direct all warranty and repair requests/inquiries to the OMEGA Customer Service Department.
BEFORE RETURNING ANY PRODUCT(S) TO OMEGA, PURCHASER MUST OBTAIN AN
DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to
OMEGA for current repair charges. Have the
OMEGA’s policy is to make running changes, not model changes, whenever an improvement is
This document may not be copied, photocopied, reproduced, translated, or reduced to any
electronic medium or machine-readable form, in whole or in part, without prior written consent
PATENT NOTICE: This product is covered by one or more of the following patents: U.S.
Pat. No. Des. 336,895; 5,274,577 / CANADA 2052599; 2052600 / ITALY 1249456;
1250938 / FRANCE BREVET No. 91 12756 / SPAIN 2039150; 2048066 / UK PATENT No. GB2 249 837; GB2 248 954 / GERMANY DE 41 34398 C2. The “Meter Case Bezel
Design” is a trademark of NEWPORT Electronics, Inc., registered in the U.S. USED
FOR NON-WARRANTY REPAIRS, consult
should then be marked on the outside of the return package and on any correspondence.
following information available BEFORE
Directives. OMEGA will add the CE mark to every appropriate device upon certification.
possible. This affords our customers the latest in technology and engineering.
damage whatsoever arising out of the use of the Product(s) in such a manner.
UNDER LICENSE. OTHER INTERNATIONAL PATENTS PENDING.
OMEGA is a registered trademark of OMEGA ENGINEERING, INC.
© Copyright 2002 OMEGA ENGINEERING, INC. All rights reserved.
contacting OMEGA:
information relating to safety and EMC.
FOR WARRANTY RETURNS, please have
the following information available BEFORE
of OMEGA ENGINEERING, INC.
coverage on each product.
prevent breakage in transit.
connected applications.
contacting OMEGA:
fuses, and triacs.
Engineering, Inc.
without notice.
READ 1
INPUT2
SETPTS /MAX /MIN MENU RESET
READ 2
SETPTS /MAX /MIN MENU RESET
Dec pt
SETPTS /MAX /MIN MENU RESET
REset2
SETPTS /MAX /MIN MENU RESET
5. Press MENU. The meter stores changes and displays:
CNTBY
Input Values section of this quick start.
“001000”. (Use /MIN to scroll through
displays “000000”. Enter the INPUT 1
through digits and /MAX to change
number. Change the meter to read
Press /MIN. The meter displays
“000000”. Enter the INPUT 2 value
number. Change the meter to read
mode. The meter is now scaled to
read 0 to 100.0 for a 4-20 mA input.
Press /MIN to display a six-digit
3. Press MENU. The meter displays “INPUT 2”:
Press /MIN to display a six digit
Press /MIN again. The meter
2. Press MENU. The meter displays “READ 1”:
“000000”. (Use /MIN to scroll
Values section of this quick start.
stored
stored
SETPTS /MAX /MIN MENU RESET
Scale Input Values
the digit’s value.)
Dec pt
SETPTS /MAX /MIN MENU RESET
FFFFFF.
INPUT1
SETPTS /MAX /MIN MENU RESET
INPUT2
SETPTS /MAX /MIN MENU RESET
IN CNF
SETPTS /MAX /MIN MENU RESET
INp6=0
SETPTS /MAX /MIN MENU RESET
CNTBY
will now read the input signal (4mA = ≈ 000000.
and /MAX to change the digit’s value).
4. Press MENU until the meter displays:
necessary, to read “FFFFFF.” (Use
/MAX to change the decimal point
Change the meter to read “INP.6=1”
(Use /MIN to scroll through digits
1. Press MENU. The meter displays:
Press /MIN to display “INP6=0”
INPUT 1 = _________________
INPUT 2 = _________________
Set Default Decimal Point
stored
Refer to this as Input One.
Refer to this as Input Two.
and 20mA = ≈ 020000.).
position).
® · ® · ®


Quick Start Setup scales your meter to read 0 to 100.0 for a
CURRNT
SETPTS /MAX /MIN MENU RESET
3. Press MENU. The meter stores changes (if applicable), then displays “RDG.CNF”:
rdg.CNF
SETPTS /MAX /MIN MENU RESET
RDG.1=0
SETPTS /MAX /MIN MENU RESET
RDG.2=1
SETPTS /MAX /MIN MENU RESET
INPUT
input range of 4-20mA or 0-20 mA.
“RDG.2=1”. Selecting “RDG.2=1”
enables an active decimal point.
stored
SETPTS /MAX /MIN MENU RESET
enables direct formatting.
Quick Start Setup
Quick Start Setup.
flashing.
b. Verify the P1 power and P3 and P9 input connections.
enter and scroll through a submenu.
change the value of a submenu.
once) or exit the configuration
menus (press twice).
P3 N/C
setpoint values.
+S
–S
–E
RTN
to the next.
c. Check your power source.
d. Check your signal source.
a. Remove ac power.
PROVIDED
(-) (4-20mA)
sensor excitation.
MENU
/MIN
/MAX
RESET
screw.
uses the C2 (4 - 20mA) range. If your meter is setup for a
DC1 - DC10 are voltage ranges. This quick start manual
Check the serial label on the top of the meter case. The
model number’s last 3 digits indicate if the meter is set up
Contact the nearest Customer Service Department using
the numbers listed on the front of this quickstart manual if
any of these parts are missing, or if you have questions .
the factory default settings of current input and 24 Vdc
range other than C2, consult the reference manual.
sensor excitation. To start your unit you:
P1 Connector
P1
N L
Using This Quick Start Manual
following items to set up your unit:
Connect ac Power
~ AC Neutral
connection.
(+)