Instruction manual IMPORT ANT Please make certain that the person who is to use this equipment carefully reads and understands these instructions before starting operations. ESP AÑOL: PÁGINA 29 FRANÇAIS: P AGE 57 T o learn more about Porter -Cable visit our website at: http://www .
2- ENG A10260 SAFETY GUIDELINES - DEFINITIONS Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury . Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury .
3- ENG A10260 IMPORT ANT SAFETY INSTRUCTIONS Save these instructions Improper operation or maintenance of this product could result in serious injury and property damage. Read and understand all warnings and operation instructions before using this equipment.
4- ENG A10260 WARNING: Risk of Bursting Air T ank: The following conditions could lead to a weakening of the tank, and result in a violent tank explosion and could cause property damage or serious injury .
5- ENG A10260 WARNING: Risk to Breathing WARNING: Risk of Electrical Shock HAZARD HAZARD Y our air compressor is powered by electricity . Like any other electrically powered device, If it is not used properly it may cause electric shock. Repairs attempted by unqualified personnel can result in serious injury or death by electrocution.
6- ENG A10260 WARNING: Risk of Burns T ouching exposed metal such as the compressor head or outlet tubes, can result in serious bur ns. Never touch any exposed metal parts on compressor during or immediately after operation. Compressor will remain hot for several minutes after operation.
7- ENG A10260 Review and underst and all instructi ons and warnings in this manual. Become famil iar with the operation and contr ols of the air compress or . Keep operati ng area clear of all persons, pets, and obstacle s. Keep childr en away fro m the air compr essor at all times .
8- ENG A10260 GLOSSAR Y DUTY CYCLE SPECIFICA TIONS Accessories for this unit are available at the store the unit was purchased. ACCESSORIES Model No. C5510 Running Horsepower 1.
9- ENG A10260 T o Install Handle The wheels and handle do not provide adequate clearance, stability , or support for pulling the unit up and down stairs or steps. The unit must be lifted or pushed up a ramp. Do not lift the unit by the manifold assembly , the unit could be damaged.
10- ENG A10260 Assemble Rubber Feet 1. Attach rubber feet with the screws, washers, and nuts provided as shown. 2. Tighten securely . T o Assemble Wheels It will be necessary to brace or support one side of the unit when installing the wheels because the compressor will have a tendency to tip.
11- ENG A10260 T o Add Oil T o Pump Compressors are shipped without oil. A small amount of oil may be present in the pump upon receipt of the air compressor . This is due to plant testing and does not mean the pump contains oil. Do not attempt to operate this air compressor without first adding oil to the crankcase.
12- ENG A10260 GROUNDING INSTRUCTIONS Risk of Electrical Shock. In the event of a short circuit, grounding reduces the risk of shock by providing an escape wire for the electric current.
13- ENG A10260 120/240 Dual V oltage Motor This model has a dual voltage motor , 120 and 240 volt. It is wired for 120 volt but can be converted to 240 volt operation. Instructions for connecting the motor for operation at 240 volt can be found printed on the label attached to the side of the motor .
14- ENG A10260 Description of Operation Become familiar with these controls before operating the unit. On/Aut o/Off Lever : T ur n this switch to " On/A uto" to provi de automat ic power to the pressur e switch and " Off" to remove power at the end of each use.
15- ENG A10260 Drain V alve: The drain valve is located at the base of the air tank and is used to drain condensation at the end of each use. Check V alve: When the air compressor is operating, the check valve is "open", allowing compressed air to enter the air tank.
16- ENG A10260 How to Start: 1. T urn the On/Auto/Off lever to "On/Auto" and allow tank pressur e to build. Motor will stop when tank pressure reaches "cut-out" pressure. 2. Pull the regulator knob out and tur n clockwise to increase pressure.
17- ENG A10260 MAINTENANCE Customer Responsibilities Daily or after each use Before each use ● ● ● ● Every 8 hours Every 40 hours Every 100 hours Y early Every 160 hours ● ● 1 1- more freq.
18- ENG A10260 T o Drain T ank NOTE: Operation of the air compressor will cause condensation to build up in the air tank. Always drain tank on a washable surface or in a suitable container to prevent damaging or staining surfaces. 1. Set the On/Auto/Off lever to "Off".
19- ENG A10260 T o Replace Belt Serious injury or damage may occur if parts of the body or loose items get caught in moving parts. Never operate the unit with the belt guard removed. The belt guard should be removed only when the compressor is unplugged.
20- ENG A10260 Air Compressor Pump Intake and Exhaust V alves Once a year have a T rained Service T echnician check the air compressor pump intake and exhaust valves.
21- ENG A10260 SERVICE AND ADJUSTMENTS T o Replace or Clean Check V alve 1. Release all air pressure from air tank. See "T o Drain T ank" in the "Maintenance" section. 2. Unplug air compressor . 3. Using an adjustable wrench loosen outlet tube nut at air tank and pump.
22- ENG A10260 T o Replace Regulator 1. Release all air pressur e from air tank. See "T o Drain T ank" in the "Maintenance" section. 2. Set the On/Auto/Off lever to "Off" and unplug unit. 3. Using an adjustable wrench remove the outlet pressure gauge and quick connect from the regulator .
23- ENG A10260 STORAGE Before you store the air compressor , make sure you do the following: 1. Review the "Maintenance" section on the preceding pages and perform scheduled maintenance as necessary . 2. Set the On/Auto/Off lever to " Off" and unplug unit.
24- ENG A10260 TROUBLESHOOTING PROBLEM CAUSE CORRECTION Pressur e switch does not shut off motor when compressor reaches "cut- out" pressur e. Pressur e switch "cut-out" too high. Move On/Auto/Off lever to the " Off" position, if the unit does not shut off contact a T rained Service T echnician.
25- ENG A10260 PROBLEM CAUSE CORRECTION Compressor is not supplying enough air to operate accessories. Prolonged excessive use of air . Compressor is not large enough for air requirement. Hole in hose. Check valve restricted. Air leaks. Restricted air intake filter .
26- ENG A10260 PROBLEM CAUSE CORRECTION Motor will not run. Fuse blown, circuit breaker tripped. 1. Check fuse box for blown fuse and replace as necessary . Reset circuit breaker . Do not use a fuse or circuit breaker with higher rating than that specified for your particular branch circuit.
27- ENG A10260 PROBLEM CAUSE CORRECTION Knocking Noise. Possible defect in safety valve. Operate safety valve manually by pulling on ring. If valve still leaks, it should be replaced. Loose pulley . Tighten pulley set screw , see Parts manual for torque specifications.
28- ENG A10260 LIMITED W ARRANTY PORTER-CABLE CORPORA TION warrants to the original purchaser that all products covered under this warranty are free from defects in material and workmanship.
An important point after buying a device Oki C5510 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Oki C5510 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Oki C5510 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Oki C5510 you will learn all the available features of the product, as well as information on its operation. The information that you get Oki C5510 will certainly help you make a decision on the purchase.
If you already are a holder of Oki C5510, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Oki C5510.
However, one of the most important roles played by the user manual is to help in solving problems with Oki C5510. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Oki C5510 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center