USER GUIDE SCC-AO10 Isolated Analog Output Module The SCC-AO10 is an isolated voltage output module wit h an output range of ±10 V. The output voltage level is controlled by the DA C output of an E/M Series DAQ device. You can incr ease the output voltage level to ±20 V by connect ing two SCC-AO 10 modules in series.
SCC-AO10 Isolated Analog Output Module Use r Guide 2 ni.com monospace T e xt in this font denotes text or ch aracters that you should enter from the keyboard, sections of code, programming examples, and syntax examples.
© National Instruments Corpor ation 3 SCC-AO10 Isolated Analog Output Mo dule U ser Guide Note Software scaling of measurements is not supported on the Macintosh operating system. Refer to the SCC-AO10 Connector Pin Assignments section. Y ou can do wnload NI documents from ni.
SCC-AO10 Isolated Analog Output Module Use r Guide 4 ni.com Figures 1 and 2 show the SCC-A O10 c onnected to a nonreferenced load and to a load w ith a hi gh common-mode voltage.
© National Instruments Corpor ation 5 SCC-AO10 Isolated Analog Output Mo dule U ser Guide Figure 3. Connecting T wo SCC-AO10 Modules in Series The SC-2345/2350 routes the E/M Series D A Q device analog output channels A O 0 and A O 1 to the SCC-A O10 modules, and the resu lting maximum output voltage range is ±20 V .
SCC-AO10 Isolated Analog Output Module Use r Guide 6 ni.com Using the SCC-AO10 This section contains information regarding scali ng voltage measurements and isolated ground references. Scaling V oltage Measurements The SCC-AO10 is a ±10 V isolated analog output module.
© National Instruments Corpor ation 7 SCC-AO10 Isolated Analog Output Mo dule U ser Guide 5. Adjust the offset potentiometer on the top of the SCC-A O10 unt il the voltmeter reads 0 VDC ±100 μ V . The of fset is no w calibrated. 6. Using your software, hav e A O ( X ) output 9.
SCC-AO10 Isolated Analog Output Module Use r Guide 8 ni.com Power Requirement Analog power ............... ................. .........180 mW max at full load 172 mW max w ith no load + 15 V .... ................. .............. ............6 mA max at full load 5.
© National Instruments Corpor ation 9 SCC-AO10 Isolated Analog Output Mo dule U ser Guide Maximum W orking Voltage (Signal + common- mode) each input should remain within 42.4 V peak or 60 VDC of ground. Maximum working voltage refers to the signal voltage plus the CMV .
SCC-AO10 Isolated Analog Out put Module Use r Guide 10 ni.com Safety This product meets the requirements of the follow ing standards of safety for electrical equipment for measurement, contro l, and l.
© National Instruments Corpor ation 11 SCC-AO10 Isolat ed Analog Output Module User Guide Environmental Management NI is committed to designing and manufacturing products in an environmentally responsible man ner. NI recognizes that eliminating certain hazardous substances from our products is beneficial to the environment and to NI customers.
National Instruments, NI, ni.com, and LabVIEW are tradem arks of National Instruments Corporation. Refer to t he Terms of Use section on ni.com/legal for mor e information a bout National Instruments trademarks. Other product and compan y names mentioned herein are trademarks or trad e names of their respective companie s.
An important point after buying a device National Instruments SCC-AO10 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought National Instruments SCC-AO10 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data National Instruments SCC-AO10 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, National Instruments SCC-AO10 you will learn all the available features of the product, as well as information on its operation. The information that you get National Instruments SCC-AO10 will certainly help you make a decision on the purchase.
If you already are a holder of National Instruments SCC-AO10, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime National Instruments SCC-AO10.
However, one of the most important roles played by the user manual is to help in solving problems with National Instruments SCC-AO10. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device National Instruments SCC-AO10 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center