1 W415-0434 / C / 03.24.05 INST ALLER: THESE INSTRUCTIONS MUST BE CONVEYED TO AND REMAIN WITH THE HOMEOWNER. Wolf Steel Ltd., 24 Napoleon Rd., Barrie, ON L4M 4Y8 Canada • (705)721-1212 • fax(705)722-6031 www .napoleonfireplaces.com • ask@napoleon.
2 W415-0434 / C / 03.24.05 PG 2-5 INTRODUCTION Warranty Dimensions General Instructions General Information Care of Glass & Plated Parts 5-10 V E N T I N G V ent lengths V enting S pecifications A.
3 W415-0434 / C / 03.24.05 ALL SPECIFICA TIONS AND DESIGNS ARE SUBJECT T O CHANGE WITHOUT PRIOR NOTICE DUE T O ON-GOING PRODUCT IMPROVEMENTS. NAPOLEON® IS A REGISTERED TRADEMARK OF WOLF STEEL L TD. PA TENTS U.S. 5.303.693.801 - CAN. 2.073.41 1, 2.082.
4 W415-0434 / C / 03.24.05 Purge all gas lines with the glass door of the fireplace op e n . Assure that a continuous gas flow is at the burner before cl o s i ng the door . Under extreme vent configurations, allow several minutes (5-15) for the flame to stabilize after ignition.
5 W415-0434 / C / 03.24.05 Do not use abrasive cleaners to clean plated parts. Buff lightly with a clean dry cloth. The glass is 3/16" ceramic glass available from your Napoleon / Wolf S teel Ltd. dealer . DO NOT SUBSTITUTE MA TERIALS. Clean the glass af ter the first 10 hours of operation with a recommended gas fireplace glass cleaner .
6 W415-0434 / C / 03.24.05 when (H T ) < (V T ) Simple venting configuration (only one 90° elbow) VERTICAL RISE IN FEET V T FIGURE 4 See graph to determine the required vertical rise V T for the required horizontal run H T .
7 W415-0434 / C / 03.24.05 H 2 H 1 V 1 90° See graph to determine the required ver- tical rise V T for the required horizontal run H T . V 1 = V T = 6 ft H 1 =3 f t H 2 =5 f t H R = H 1 + H 2 = 3 + 5 = 8 ft H O = .03(two 90° elbows - 90°) = .03(180° - 90°) = 2.
8 W415-0434 / C / 03.24.05 REQUIRED VERTICAL RISE IN F E E T V T HOR IZON T AL VENT RUN PLUS OFFSET IN FEET H T The shaded area within the lines represents acceptable values for H T and V T .
9 W415-0434 / C / 03.24.05 0 51 0 1 5 2 0 10 20 3 25 30 19 MAXIMUM VERTICAL RISE IN FEET V T HO RIZ O N T AL VENT RUN PLUS OFFSET IN FE E T T The shaded area within the lines represents acceptable values for H T and V T . See graph to determine the required vertical rise V T for the required horizontal run H T .
10 W415-0434 / C / 03.24.05 AIR TERMINAL INST ALLA TIONS * * * Recommended to prevent condensation on windows and thermal breakage * * * * * * * * * * It is recommended to use a hea t shie ld and to maximize the distance to vinyl clad soffits.
11 W415-0434 / C / 03.24.05 FIGURE 14 OR This application occurs when venting through a roof. Installation kits for various roof pitches are available from your Na- poleon dealer .
12 W415-0434 / C / 03.24.05 FIGURE 20 Use only approved aluminum flexible liner kits marked " Wo lf Steel Appr oved V enting" as identified by the stamp only on the 7" outer liner . For optimum performance it is recommended that all horizontal runs have a minimum ¼ inch rise per foot using flexible venting.
13 W415-0434 / C / 03.24.05 FIGURE 23 1. Move the fireplace into position. 2. Fasten the roof support to the roof using the screws provided. FIGURE 16. The roof support is optional. In this case the venting is to be adequately supported using either an alternate method suitable to the authority having ju- risdiction or the optional roof sup- port.
14 W415-0434 / C / 03.24.05 * * * * * When using the optional ornamental facia and panels, the minimum height from the top of the unit to the mantle is 7". ** A steel stud header is recommended, however tradi- tional combustible header material may be used.
15 W415-0434 / C / 03.24.05 Combustible mantle clearance can vary according to the mantle depth. Use the graph to help evaluate the clear- ance needed. FIGURE 37 MANTLE CLEARANCES ** EXAMPLE A - NON-COMB USTIBLE MA TERIAL It is best to frame your fireplace after it is positioned and the vent system is installed.
16 W415-0434 / C / 03.24.05 Open the valve control door. Hook the top and bottom door latches, located at the right side of the door into the corre- sponding slots in the door.
17 W415-0434 / C / 03.24.05 A C B L38 LOUVRE INST ALLA TION FIGURE 43 a-c HOOD Attach the hood by pressing the top flange into the clips along the top of the louvre opening. Secure using a screw through the centre slot. LOWER LOUVRES Insert the hinge clips into the slots located at the bottom left and right corners of the unit.
18 W415-0434 / C / 03.24.05 Glowing embers (not supplied) maybe used to enhance the flame's appearance. 4. Place log #4, with the charred branch pointed inward. Locate the pins into the holes in log#1 and log#2, this will hold the rear log in position.
19 W415-0434 / C / 03.24.05 The FIRE LOG ACCENT LIGHT is provided with a manual "in- line" switch to turn the light on and off. There are alternate meth- ods of operating the light. An example of one method would be to "hard-wire" a wall switch.
20 W415-0434 / C / 03.24.05 BL OWER INST ALLA TION FIGURE 51 The Napoleon ST ARfire comes equipped with a blower , a heat sensor , variable on/off speed control and a power cord.
21 W415-0434 / C / 03.24.05 A. This fireplace is equipped with a pilot which must be lit by hand while following these instructions exactly . B. Before operating smell all around the fireplace area for gas and next to the floor because some gas is heavier than air and will settle on the floor .
22 W415-0434 / C / 03.24.05 Closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports. The flame may not appear yellow immediately; allow 15 to 30 minutes for the final flame colour to be estab- lished.
23 W415-0434 / C / 03.24.05 # P A RT NO . DESCRIPTION 1 W135-0205 # 1 - R EA R L OG 2 W135-0206 # 2 - M I DDLE LOG 3 W135-0207 # 3 - RIG HT LO G 4 W135-0208 # 4 - LEF T L OG 5 W135-0218 # 5 - C RO SS .
24 W415-0434 / C / 03.24.05 * W ARNING: This is a fast acting thermocouple. It is an integral safety component. Replace only with a fast acting thermocouple supplied by Wolf S teel Ltd.
25 W415-0434 / C / 03.24.05 White / grey film forms. Sulphur from fuel is being deposited on glass, logs or combustion chamber sur- faces. - clean the glass with a gas fireplace glass cleaner . DO NOT CLEAN GLASS WHEN HOT . If deposits are not cleaned of f regularly , the glass may become permanently marked.
26 W415-0434 / C / 03.24.05 Remote wall switch is in "OFF" position; main burner comes on when gas knob is turned to "ON" po- sition. Wall switch is mounted up- side down - reverse. Faulty valve. - replace. - replace. Remote wall switch is grounding.
27 W415-0434 / C / 03.24.05 W olf Steel Fir eplace Ser vice Histor y This fireplace must be serviced annually depending on usage. Date Service T echnician Name Service Performed Special Concerns Deale.
28 W415-0434 / C / 03.24.05 NO TES.
An important point after buying a device Napoleon Fireplaces GD70NT-S (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Napoleon Fireplaces GD70NT-S yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Napoleon Fireplaces GD70NT-S - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Napoleon Fireplaces GD70NT-S you will learn all the available features of the product, as well as information on its operation. The information that you get Napoleon Fireplaces GD70NT-S will certainly help you make a decision on the purchase.
If you already are a holder of Napoleon Fireplaces GD70NT-S, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Napoleon Fireplaces GD70NT-S.
However, one of the most important roles played by the user manual is to help in solving problems with Napoleon Fireplaces GD70NT-S. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Napoleon Fireplaces GD70NT-S along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center