Instruction/ maintenance manual of the product XP-400 Napco Security Technologies
Go to page of 28
XP-400 & RPXP4GT keypad Control Panel/Communicator Installation Instructions W I1370 1/05 © NAPCO 2005 ®.
2 WI1370 XP-4 00 Inst alla tion Instru ctio ns General Information The NAP CO EXPRESS XP-400 contr ol panel provides up to 4 ha rdwired/w ireless zon es. Up t o four 4-digit user co des can be prog rammed. A mbush, when sel ected, us es User 4 code as an A mbush code.
3 Specifications Current & Vo ltage Rating s Alarm Output ------------- ------------- Burg: 12 VDC, 2A (max.) Output Current Limiting -- ------------ Burg: 2.
4 WI1370 XP-4 00 Inst alla tion Instru ctio ns 4 zone Control Panel Keypad Zone Doubling Resistors (2.2K & 3.9K) Operating Instructions XP-400 Programming Instructions XP-400 XP-400 RPXP4GT ZDR OI.
5 Programming the Panel Ref er to XP-4 00 Prog ram min g Inst ructi ons (WI1 371) Defaulting the Panel 1. Remove power from the panel. 2. Rem ove all wiring f rom terminal 15 (PGM) and terminal 3. 3. Connect terminal 15 (PGM) to terminal 3. 4. Apply power to the XP-400 control panel.
6 WI1370 XP-4 00 Inst alla tion Instru ctio ns Installa tion Mounting the Panel Mount the Panel close to an unswi tched AC source, a cold-water pipe ground, and a telephone line connection. Mounting the Keypad A keypad should be located near an e xit/entry door.
7 PGM Wiring The PGM is a switched negativ e output that is activated depending on th e programming option (s) that have been selected [ 08], [23] - [25]. Connect the devi ce controlled by the PGM between +PWR and th e PGM terminal (maximum load of 50 mA).
8 WI1370 XP-4 00 Inst alla tion Instru ctio ns A rming /Dis armin g with a K eyf ob The system can be armed by pr essing the K key, and disarmed by pressing the L key on the Keyfob. Zones programmed as Exit/Entry Follower Zones can be bypassed when the M or N keys on the Keyfob hav e been programmed for Interior [81- 82].
9 Full Setting the S ystem with Automatic Byp as sing - H ome /A way with De lay Zones From the Keypad Press C B to return protection to Home /Away wit h Dela y Zone s that have been automatically bypassed. T hree minutes are allowed to walk through Exit/ Entry and Exit/Entry Follower Zones .
10 WI1370 XP-4 00 Inst alla tion Instru ctio ns While in Us er Progr am Mode t he W Armed, X READY and H System Trouble LEDs will continue to fl ash, follow the example below to program a User 2’s code to 1923. User Mode Pr ogr amm ing Exa mple : 1.
11 Dealer Comm ands A6 Download (Programming Requi red) Establish a connection b etween the PCD phone line and the Control Panel phone line. W hen ready, tell the installer to arm, then disarm. Then enter A6 in order to establish a connection. Phone connection to installer will go "dead" as downloader and panel connect.
12 WI1370 XP-4 00 Inst alla tion Instru ctio ns To eliminate this fixed 20-second entry delay, also program zones as Exit/Entry Follower Zones [02]. To return protection to zones of this type, press cb from the keypad or M or N from a Keyfob. Program the Keyfob AUX 1 or AUX 2 button for Full Set [81-7].
13 [08]PGM Output Enables the PGM Output on a zone trip for each zone selected. The PGM Output will remain ON until reset. System Times [10]E xit D elay The delay time which perm its exit through an Exit/Entry Zone [00] after the system is armed, allows a user to leave the prem ises without setting off an immediate alarm.
14 WI1370 XP-4 00 Inst alla tion Instru ctio ns [21]Ke yp ad Features 2 (1) Audible Panic - Keypad Panic will not turn the Bell on unless thi s option is programmed. (2) Exit/Entry with Urgency - select to give an audible indication of Exit and Entry tim es.
15 (3) Panic - Progr am to activate the PGM on a Panic alarm. (4) Test Time r - Program to activate the PGM during a Test Ti mer report. [25]Programmable Output Features 3 (1) AC Fail - Program to activate the PGM on the loss of AC. (15 minute delay) (2) Low Battery - Program to activ ate the PGM on a Low Battery condition.
16 WI1370 XP-4 00 Inst alla tion Instru ctio ns Pager Alarm data is the same as 4/2 fo rmat with the exception that the 2 digit Report Code is transmitted before the 4 digit Subscriber ID. [33]Receiv er Options (1) 2300 Hz HS/Kissoff - Select 2300 H z Handshake and Kissoff.
17 [37]System Repor ting, Telco 1 (1 ) Y AC F a i l R e p o r t - Pro gram to acti vat e a n AC Fail report (15 minute f ixed report dela y). (2) Low Bat tery Report - Program to activate a Low Battery report. (3) *Trouble Report - Program to activate a Trouble report.
18 WI1370 XP-4 00 Inst alla tion Instru ctio ns Telephone Number 3 Programming [50] - [59] Programming is the same as for Telco 1. Program to split/double report to Telco 3. Refer to sections [30] through [39]. Report Codes [60] Zo ne R eport Co des Report Code fo r Zones 1 through 4.
19 [66]Ambush Re port Code Program a 2-digit report code for Ambush. To send an ambush report, pro gram a User Code for User 4, Program report User 4 as Ambush [20-4] and Select reporting f or Telco 1 [36-2] and/or Telco 3 [56-2].
20 WI1370 XP-4 00 Inst alla tion Instru ctio ns [71-74] Wirel ess Transmitters Enter the RF ID# and the point number that is to be mapped to the zone. Programming Exampl e Map point 1 of a window door transmitter with an RF ID# of 0012B0:0 to Zone 3. 1.
21 7 Full Set System Program a 7 in the AUX 1 and/or AUX 2 option to Fully Set the System when the K and the M or N butt on s on th e Keyfob are pressed, or when the M or N buttons are pressed when the system is armed with Exit/Entry Follower Zones or Home/Away with Delay Zones that have been bypassed.
22 WI1370 XP-4 00 Inst alla tion Instru ctio ns Site At the site perform the following three steps: 1. Arm the panel. 2. Disarm the panel. 3. Enter A6 .
23 System Trouble s Use the System Trouble chart on the following page to determine the specific System Trouble (s). During normal panel operation th e H SYSTEM LED has the following two modes of op e.
24 WI1370 XP-4 00 Inst alla tion Instru ctio ns Keypad Beeps or H SYSTEM Flashes Zone LED ON System Trouble Condition Cause/Action 1 Beep Y LED 1 Y AC Power Failure Thi s tro ubl e will occur if AC power i s not presen t. Ensure that t he tr ansfo r mer is c onne cted to an uns witc hed po wer so urc e.
25 Troubles hooting 1. The bell output drops to about 3 volts in alarm. The ba tte ry/b ell ci rcuit i s p rotect ed by a PC boa rd trac e whic h may have bu rned open by reversal of the battery leads. It is on the ba ck of th e PC boa rd just adja cent to the re d & black battery leads.
26 WI1370 XP-4 00 Inst alla tion Instru ctio ns 8. How do I remove Keypad Sounde r on Ala r m? The keypad sounder follows the Bu rg Output. If you need to remove the Ke ypad Soun der, the n you m ust rem ove the B urg Output from that zone. 9. Transmitters not responding? Open Transm itte r cas e - Keypad shou ld go into X-Mitter Tamper Trouble.
27 16 VAC 20 VA TRAN SFO R MER NAPCO TRF12 (OR EQUIVALENT SEE WI1370). Class 2 Tra nsf orm e r. (3) -4 +5 +6 1 2 +3 GEM-RECV-XP8 + RED (+) BLACK E1 E2 RECHA RGEA BLE BATTER Y 12 VDC 4AH OR 7AH ALL OUT.
NAPCO LI MI TED WARR ANTY NAPC O SECU RIT Y SYST EMS , INC. (NAPC O) war rants its produ cts to b e free fr om man ufact urin g defect s in mat erials and work m anship f or thirty-six m onths follo wing the date of manufacture.
An important point after buying a device Napco Security Technologies XP-400 (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Napco Security Technologies XP-400 yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Napco Security Technologies XP-400 - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Napco Security Technologies XP-400 you will learn all the available features of the product, as well as information on its operation. The information that you get Napco Security Technologies XP-400 will certainly help you make a decision on the purchase.
If you already are a holder of Napco Security Technologies XP-400, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Napco Security Technologies XP-400.
However, one of the most important roles played by the user manual is to help in solving problems with Napco Security Technologies XP-400. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Napco Security Technologies XP-400 along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center