
and MT3334ZDXV
Data/Fax Modem Data/Fax/Voice Modem
Owner's Manual (User Guide)

Models MT3334ZDX and MT3334ZDXV
This publication may not be reproduced, in whole or in part, without prior expressed written permission from Multi-Tech Systems, Inc. All rights reserved.
Copyright © 1997-2004, by Multi-Tech Systems, Inc.
Multi-Tech Systems, Inc. makes no representations or warranties with respect to the contents hereof and specifically disclaims any implied warranties of merchantability or fitness for any particular purpose. Furthermore, Multi-Tech Systems, Inc. reserves the right to revise this publication and to make changes from time to time in the content hereof without obligation of Multi-Tech Systems, Inc. to notify any person or organization of such revisions or changes.
This Product is covered by one or more of the following U.S. Patent Numbers: 5.301.274; 5.309.562; 5.355.365; 5.355.653; 5.452.289; 5.453.986; 5,535,204. Other Patents Pending.
A Initial release for publication on CD (4/26/04)
Previous release incorporated new commands. (11/24/97)
MultiModem, MultiModemZDX/V, Multi-Tech, and the Multi-Tech logo are trademarks of Multi-Tech Systems, Inc. Microsoft, Windows, and Windows 95 are registered trademarks of the Microsoft Corporation. All brand and product names mentioned in this publication are trademarks or registered trademarks of their respective companies.
Multi-Tech Systems, Inc.
2205 Woodale Drive Mounds View, Minnesota 55112 U.S.A.
(763) 785-3500 or (800) 328-9717
Technical Support (800) 972-2439 Internet Address: http://www.multitech.com
User Guide · S000343A Revision A · Revision Description


Introduction
Welcome to the world of data communications. You have acquired one of the finest intelligent data/fax modems available today, the MultiModemZDX, from Multi-Tech Systems. This Owner’s Manual will help you install, configure, test and use your MultiModemZDX.
In addition to the contents of the MultiModemZDX package, you will need the following equipment.
The MultiModemZDX (MT3334ZDX or MT3334ZDXV) can be connected to any computer with an RS-232 serial port, such as the IBM PC, XT, AT, and PS/2 computers, and most IBM compatibles. Note that your computer system should have a processing speed of at least 75 MHz in order to take full advantage of the telephony features of this product.
You will need a serial cable to connect the MultiModemZDX to your computer. Serial cables are available at computer stores and many office supply stores. The cable must have a DB-25P connector at the modem end. For IBM and compatible computers, the other end may have a DB- 25P connector or a DB-9S connector, depending on your particular computer and whether you are using the COM1 or the COM2 serial port.
You must have a telephone line with a conveniently located connector (jack) to accept the cable that comes with the MultiModemZDX. If you do not have a telephone jack near your computer, you should install an extension before proceeding.

You will need data communications (datacomm), fax communications software and, for the MultiModemZDX, an appropriate application software package to access the Personal Voice-Mail features of the MultiModemZDXV. The MultiModemZDX is also compatible with datacomm and fax programs you may already own.
General features include:

This manual is divided into five chapters and three appendices. The information contained in each chapter and appendix is as follows:
Chapter 1 begins with a short product introduction and description; followed by a guide (which you are now reading) to the use of this manual.
Chapter 2 documents the procedure for connecting the MultiModemZDX to your computer and to the phone line. Details are given, supported by illustrations as a guide for installing your MultiModemZDX to the point of operation. There is also a Troubleshooting section in the event your MultiModemZDX is not operating properly.

Chapter 3 documents default and option ATcommands, S-Registers and Result Codes supported by the MultiModemZDX.
Chapter 4 covers the modem's built-in test features. These are: Power- on Self Test, Local Analog Loopback, Digital Loopback and Remote Digital Loopback Tests. We have included a description of each test and how to use each test procedure.
Chapter 5 provides instructions for getting modems serviced at the factory, statements on your ten-year warranty, information about our user Bulletin Board Service (BBS) and receiving technical support via the CompuServe and Internet forums.
Appendix A - Technical Specifications
Appendix B - Tone Dial Frequencies
Appendix C - Regulatory Information

Introduction
This chapter will provide you with the basic steps necessary to install and configure your MultiModemZDX. Before attempting any procedure, be sure to read the safety warnings in the following section.
The installation of the MultiModemZDX consists of making the physical connections necessary to render the modem functional with your computer. This includes making the proper serial, phone line, and power connections.
RS232 PHONE LINE
RJ11/PSTN Connection Power Connector (to Transformer)
Figure 2-1. MultiModemZDX Connections
DB25 to Computer · RJ11/Phone Connection

To install your MultiModemZDX:
The LINE jack is not interchangeable with the PHONE jack on the MultiModemZDX. Do not plug the telephone into the LINE jack or the line cable into the PHONE jack.
6. Make sure modem and computer/terminal serial port baud rates are adjusted. (Note that several programs can check this for you. If you have MS-DOS 5.0 or higher, a program called MSD.EXE [Microsoft Diagnostics] is in your DOS directory. Typing MSD at the DOS prompt brings up a screen that provides a variety of information about your computer. Select COM ports and it lists information about your com port, e.g., UART Type, Address, and IRQ, to name a few. Once you know your serial port's UART type, you can set your communications's software appropriately.)



The MultiModemZDX has ten LED indicators (Figure 2-3) to report status (such as verifying proper installation) and line activity (such as monitoring the status of a connection).
Figure 2-3. Front Panel
Transmit Data. The TD LED flashes when data is being transmitted (on for a space, off for a mark). Signals on this circuit are generated by the terminal and transferred to the transmitter of the MultiModemZDX. The transmitting terminal should hold this line in the marking state when no data is being transmitted, including intervals between characters or words. The TRANSMIT (TD) LED indicates the status of this circuit.
Receive Data. The RD LED flashes when data is being received (on for a space, off for a mark). Data signals received from the remote MultiModemZDX are presented on this line. When no carrier signal is being received (pin 8 negative), this line will be forced into a marking condition. The RECEIVE (RD) LED indicates the status of this signal.

Carrier Detect. This LED lights when a valid carrier signal from another modem is detected.
V.34. This LED is lit when the modem is connected in V.34 mode at 33,600 bps.
V.32bis. This LED is lit when the modem is connected in V.32bis mode. Note at speeds lower than a V.32bis connection, the MultiModemZDX speed LEDs remain unlit.
9600bps. This LED is lit when the modem is connected at 9600 bps.
Off Hook. The condition of Off Hook indicates to the central office that the MultiModemZDX wants the phone line to do something (i.e., dial or answer a call). This LED is also lit when the MultiModemZDX has achieved on-line status.

Terminal Ready. When TR is lit, the MultiModemZDX can answer an incoming call. This signal (TR or DTR) provides a means for the terminal or computer to control the MultiModemZDX's connection to the communications channel. A high DTR signal is required by the MultiModemZDX to be able to communicate. The state of the TR LED matches that of the DTR circuit on pin 20 of the RS232/V.24 interface.
Error Correction. This LED is lit when the modem is set for V.42 error correction, and flashes on and off when data compression is activated.
Fax. This LED is lit when the modem is connected in Fax mode.
As soon as you have connected power to the modem, if you’re an experienced modem user, you may simply want to check your modem’s settings for data compression, error correction, and so on. You may find that you can get moving quite quickly if you just issue the AT&V<cr> command. This command lists how your modem is currently configured. If you come across a setting you’re unsure of, refer to Chapter 3 of this manual for AT command and S-Register explanations and defaults. If you’re a novice, please continue to the next sections of this chapter.

You control your MultiModemZDX by issuing AT commands and setting S-Registers. Right now your MultiModemZDX is set up for the most typical user application, that is, as a traditional modem set to make a dial-up call to a remote installation where the call is answered automatically; therefore, you shouldn’t need to change the current default configuration. (If however, you know that your application does not follow this profile, please refer to Chapter 3 for AT Commands and S-Registers.)
In operating your MultiModemZDX it is likely that you will use your data communications software to either:
Either way, you need to understand that an AT command is the method by which your modem is controlled, and must therefore prefix nearly all commands. AT stands for attention, and alerts the modem that a command follows. You may enter these commands with either upper- or lower-case characters. Entering AT automatically sets the modem’s serial baud rate to match your computer’s and also sets the modem’s parity. It also clears the modem’s command buffer. Once you’re in terminal mode, enter AT followed by <CR> to check whether your modem is operational. If everything’s fine, your modem will respond OK.
You can dial by using the ATD command and the phone number of the modem with which you wish to connect, e.g., ATD6127853500. Your modem will dial the number; a “scrambling” noise is heard as the modem negotiates the kind of connection it can make, and once the modems have settled on a common connection, a connect message on your computer’s video is displayed. To hang up a call, enter +++ATH<CR>. Your modem will return on hook, just as if you had returned a phone’s handset to its cradle. Your video now displays OK, signifying that your modem is ready for your next command.

The Remote Configuration feature is a network management tool that allows you to configure modems remotely. This means you could configure modems anywhere in your network from one location without having to visit the sites or rely on remote users to follow your instructions. You can download new parameters and implement new features.
S-Register S9 has been set up to contain the special Remote Configuration escape code. When calling a Remote Configuration equipped modem, you enter the proper Remote Escape Code entering your Set-up Password. You can then execute AT commands as if you were connected locally. If you set S-Register S9 to 0 (zero), Remote Configuration is disabled. Setting S9 to a value other than zero, defines the escape key. For example, if S9 = 37, the % (percent sign) would be the escape key. The S9 value can be stored with the &W0 command.
To store the remote configuration password, type the following:
The password can be from 1 to 8 characters in length and is case sensitive. This password can be changed in command mode but not in remote configuration. If no user password has been stored, the default password is "MTSMODEM". If a user password has been set, the default password is disabled.
To enter Remote Configuration from online mode, enter the value in S9 three times, the type ATpassword . For example:
If S9 = 37, enter: %%%ATpassword and you will be in command mode.
AT#S=password

Communications software must be configured to work with the MultiModemZDX, your computer, and the remote system it is calling. Fortunately, most communications programs make the process easy by providing a default initialization string to your modem as well as defaults for most of the other required parameters.
Some software programs allow you to select your modem type from a menu. By this method, initialization strings that correspond to a particular modem type can be selected to operate optimally with the software it is utilizing.

Figure 2-4. MultiModemZDX Initialization Setup
Other software programs require you enter an initialization string in the software modem setup screen. If this is the requirement in your software application, enter the following command string to initialize your modem: AT&F<cr>
This setting configures your modem to operate optimally with the software it is utilizing.

To confirm that your modem (hardware) and communications package (software) is working properly:

Figure 2-5. MultiModemZDX Configuration Confirmation

Your MultiModemZDX was thoroughly tested at the factory before it was shipped. If you are unable to make a successful connection or if you experience data loss or garbled characters during your connection, it is possible that the modem is defective. However, it is more likely that the source of your problem lies elsewhere. Problems you may encounter include:
When you turn on the MultiModemZDX, the LED indicators on the front panel should flash briefly as the modem runs a self-test. If the LEDs remain off, the modem is probably not receiving power.


To look for address or IRQ conflicts if you use Windows 3.1x, select File, Run in Program Manager, type MSD, and press ENTER. Then select Mouse, COM Ports, and IRQ Status and note the addresses and IRQs that are in use. If you find an IRQ conflict, note which IRQs are not being used, then change one of the conflicting devices to use one of the unused IRQs. If you find an address conflict, change the address of one of the conflicting devices.
To change a port address or IRQ in Windows 3.1x, double-click the Control Panel icon, then the Ports icon. Click on the port you want to change, click Settings, click Advanced, and select the new port address and/or interrupt. If you wish to use COM3 or COM4, note that COM3 shares an IRQ with COM1, as does COM4 with COM2, so you should change their IRQs to unused ones, if possible.
If you use Windows 95, right-click on My Computer, select Properties from the menu, click on the Device Manager tab, double-click on Ports, then double-click on the Communications Port your modem is connected to. In the port’s Properties sheet, click on the Resources tab to see the port’s Input/Output range and Interrupt Request. If another device is using the same address range or IRQ, it will appear in the Conflicting Device List. Uncheck Use Automatic Settings to change the port’s settings so they do not conflict with the other device, or select the port the conflicting device is on and change it instead. If you need to open your computer to change switches or jumpers on the conflicting device; refer to the device’s documentation.

There can be several reasons the MultiModemZDX fails to make a connection. Possibilities include
You can narrow the list of possibilities by using extended result codes. To enable them, enter ATV1X4 and press ENTER while in terminal mode, or include V1X4 in the modem’s initialization string. When you dial again, the modem will report the call’s progress.
If you must dial 9 to get an outside line, the easiest way to dial it automatically is to include it in the modem’s dial prefix, e.g., ATDT9,. Note the comma, which inserts a pause before the number is dialed. By inserting 9, into the dial prefix, you do not have to include it in each directory entry.

To change the dial prefix in your communications package, select Setup, Modem; then select the modem type you are using, and type the new prefix in the Dial Prefix box. To change the dial prefix in Windows Terminal, select Settings, Modem Commands. To change it in Windows 95 HyperTerminal, select Call, Connect from the menu bar, click Dialing Properties, and type 9 in the local and long distance boxes in How I Dial from This Location.

You can automatically disable call waiting by including the disabling code in the modem’s dial prefix (e.g., ATDT*70,—note the comma, which inserts a pause before the number is dialed). To change the dial prefix in your communications package, select Setup, Modem; then select the modem type you are using, and type the new prefix in the Dial Prefix box. To change the dial prefix in Windows Terminal, select Settings, Modem Commands. To change it in Windows 95 HyperTerminal, select Call, Connect from the menu bar, click Dialing Properties, check This Location has Call Waiting, and select the correct code for your phone service.



Result Codes
Command Summary
This section summarizes your modem’s AT commands, S-Registers and Result codes.
Command: AT Attention Code Values: n/a Description: The attention code precedes all command lines except A/ and the escape sequence.
Command: ENTER or Carriage Return <CR> Key Values: n/a Description: Press the ENTER or Carriage Return key to execute most commands.
Command: A Answer Values: n/a Description: Answer an incoming call before the final ring.
Command: A/ Repeat Last Command Values: n/a Description: Repeat the last command string. Do not precede this command with AT. Do not press ENTER to execute.
Command: Bn Communication Standard Setting Values: n = 0 or 1 Default: 1 Description: B0 Select ITU-T V.22 mode when modem is at 1200 bps.
B1 Select Bell 212A when modem is at 1200 bps.
Command: Cn Carrier Control Values: n = 1 Default: 1 Description: C1 Normal transmit carrier switching (included for backward compatibility with some software).

Command: Ds Dial Values: s = dial string (phone number and dial modifiers) Default: none Description: Dial telephone number s, where s may be up to 40 characters long and include the 0–9, *, #, A, B, C, and D characters, and the L, P, T, V, W, S, comma (,), semicolon (;), !, @, ^ and $ dial string modifiers.
Dial string modifiers:
L Redial last number. (Must be placed immediately after ATD.) P Pulse-dial following numbers in command . T Tone-dial following numbers in command (default). V Switch to speakerphone mode and dial the following number. Use ATH command to hang up. W Wait for a new dial tone before continuing to dial. (X2, X4, X5, X6, or X7 must be selected.) S Dial a telephone number previously stored using the &Zn=x command (see &Zn=x command for further information). The range of n is 0-3. , Pause during dialing for time set in register S8. ; Return to command mode after dialing. (Place at end of dial string.) ! Hook flash. Causes the modem to go on-hook for one-half second, then off-hook again. @ Wait for quiet answer. Causes modem to wait for a ringback, then 5 seconds of silence, before processing next part of command. If silence is not detected, the modem returns a NO ANSWER code. $ Calling Card “Bong” Detection ^ Disable data calling tone transmission.
Command: En Echo Command Mode Characters Values: n = 0 or 1 Default: 1 Description: E0 Do not echo keyboard characters to the computer. E1 Do echo keyboard characters to the computer.

Command: Fn Echo Online Data Characters Values: n = 1 Default: 1 Description: F0 Enable online data character echo. (Not supported.) F1 Disable online data character echo (included for backward compatibility with some software).
Command: Hn On-Hook/Off-Hook Control Values: n = 0 or 1 Default: 0 Description: H0 Go on-hook to hang up. H1 Go off-hook to make the phone line busy.
Command: In Information Request Values: n = 0–4 Default: None Description: I0 Display default speed and controller firmware version. I1 Calculate and display ROM checksum (e.g., “12AB”). I2 Check ROM and verify the checksum, displaying OK or ERROR. I3 Display default speed and controller firmware version. I4 Display firmware version for data pump (e.g., “94”).
Command: Ln Monitor Speaker Volume Values: n = 0, 1, 2, or 3 Default: 2 Description: L0 Select low volume. L1 Select low volume. L2 Select medium volume. L3 Select high volume.
Command: Mn Monitor Speaker Mode Values: n = 0, 1, 2, or 3 Default: 1 Description: M0 Speaker always off. M1 Speaker on until carrier signal detected. M2 Speaker always on when modem is off-hook. M3 Speaker on until carrier is detected, except while dialing.

Command: Nn Modulation Handshake Values: n = 0 or 1 Default: 1 Description: N0 Modem performs handshake only at communication standard specified by S37 and the B command. N1 Modem begins handshake at communication standard specified by S37 and the B command. During handshake, fallback to a lower speed can occur.
Command: On Return Online to Data Mode Values: 0 or 1 Default: None Description: O0 Exit online command mode and return to data mode (see +++AT Escape Sequence command). O1 Issue a retrain and return to online data mode.
Command: Qn Enable/Disable Result Codes Values: n = 0 or 1 Default: 0 Description: Q0 Enable Result Codes. Q1 Disable Result Codes.
Command: Sr=n Set Register Value Values: r = S-register number; n varies Default: None Description: Set value of register Sr to value of n, where n is entered in decimal format.
Command: Sr? Read Register Value Values: r = S-register number Default: None Description: Read value of register Sr and display value in 3- digit decimal form.
Command: Vn Terse/Verbose Result Code Format Values: n = 0 or 1 Default: 1 Description: V0 Displays Result Codes as digits (terse response). V1 Displays Result Codes as words (verbose response).

Command: Xn Result Code Selection Values: n = 0–4 Default: 4 Description: X0 Basic Result Codes (e.g., CONNECT); does not look for dial tone or busy signal. X1 Extended Result Codes (CONNECT 33600 V42bis, etc.); does not look for dial tone or busy signal. X2 Extended Result Codes with NO DIALTONE; does not look for busy signal. X3 Extended Result Codes with BUSY; does not look for dial tone. X4 Extended Result Codes with NO DIALTONE and BUSY.
Command: Yn Long Space Disconnect Values: n = 0 Default: 0 Description: Y0 Disable sending or responding to long space break signal on disconnect. Y1 Enable sending or responding to long space break signal on disconnect. (Not supported.)
Command: Zn Modem Reset Values: n = 0 or 1 Default: None Description: Z0 Reset modem to profile saved by the last &W command. Z1 Same as Z0.
Command: &Cn Data Carrier Detect (DCD) Control Values: n = 0 or 1 Default: 1 Description: &C0 Ignores the state of carrier on the remote modem and DCD circuit is always on. &C1 DCD turns on when the remote modem’s carrier signal is detected and DCD is off when the carrier signal is not detected.

Command: &Dn Data Terminal Ready (DTR) Control Values: n = 0, 1, 2, or 3 Default: 2 Description: &D0 Modem ignores the true status of the DTR signal and responds as if it is always on. &D1 When DTR drops while in online data mode, the modem enters command mode, issues an OK, and remains connected. &D2 When DTR drops while in online data mode, the modem hangs up. &D3 When DTR drops, the modem hangs up and resets as if an ATZ command were issued.
Command: &Fn Load Factory Default Settings Values: n = 0 Default: None Description: &F0 Load factory settings as active configuration.
Command: &Gn V.22bis Guard Tone Control Values: n = 0, 1, or 2 Default: 0 Description: &G0 Disable guard tone. &G1 Enable 550 Hz guard tone. &G2 Enable 1800 Hz guard tone.
Command: &Jn Auxiliary Relay Control Values: n = 0 Default: 0 Description: &J0 The auxiliary relay is never closed. &J1 Not supported—responds ERROR.
Command: &Kn Flow Control Selection Values: n = 0, 3, or 4 Defaults: 3 Description: &K0 Flow control disabled. &K3 Enable CTS/RTS hardware flow control. &K4 Enable XON/XOFF software flow control.
Command: &Mn Communications Mode Values: n = 0 Defaults: 0 Description: &M0 Asynchronous mode.

Command: &Qn Asynchronous Communications Mode Values: n = 0, 5, or 6 Defaults: 5 Description: &Q0 Asynchronous with data buffering. Same as \N0. &Q5 Error control with data buffering. Same as \N3. &Q6 Asynchronous with data buffering. Same as \N0.
Command: &Sn Data Set Ready (DSR) Control Values: n = 0 or 1 Default: 0 Description: &S0 Force DSR high (on). &S1 Let DSR follow CD.
Command: &Tn Test Commands Values: n = 0, 1, 3 or 6 Default: None Description: &T0 Abort. Stop any test in progress. &T1 Local analog loop test. &T3 Local digital loopback test. &T6 Remote digital loopback test.
Command: &V View Current Configuration Values: n/a Description: Displays the active modem settings.
Command: &Wn Store Current Configuration Values: n = 0 Default: None Description: &W0 Store active modem settings in NVRAM; load them at power-on or following the ATZ command instead of loading the factory defaults from ROM.
Command: &Yn Select Stored Configuration for Hard Reset Values: n = 0 Default: 0 Description: &Y0 Select stored configuration 0 on power-up. (For backward compatibility with some software.)
Command: &Zn=x Store Telephone Number Values: n = 0, 1, 2 or 3 x = Dialing string Default: None Description: Stores telephone dial string x in memory location n. Dial the stored number using the command ATDS=n.

Command: \Kn Set Break Control Values: n = 5 Default: 5 Description: \K5 Modem sends break signal received from the DTE to the remote modem.
Command: \Nn Error Correction Mode Selection Values: n = 0–5 Default: 3 Description: \N0 Non-error correction mode with data buffering (same as &Q6). \N1 Direct mode. \N2 MNP reliable mode. \N3 V.42/MNP auto-reliable mode. \N4 V.42 reliable mode. \N5 V.42, MNP, or non-error correction (same as \N3).
Command: \Vn Protocol Result Code Values: n = 0 or 1 Default: 1 Description: \V0 Disable protocol Result Code appended to DCE speed. \V1 Enable protocol Result Code appended to DCE speed.
Command: %Cn Data Compression Control Values: n = 0 or 1 Default: 1 Description: %C0 Disable V.42bis/MNP 5 data compression. %C1 Enable V.42bis/MNP 5 data compression.
Command: $D DTR Dialing Values: n = 0 or 1 Default: 0 Description: $D0 Disables DTR Dialing. $D1 Enables DTR Dialing.

Command: $MB Modem Baud Rate Values: n = speed Default: 33600 Description: $MB75 Selects CCITT V.23 mode. $MB300 Selects 300 bps on-line. $MB1200 Selects 1200 bps on-line. $MB2400 Selects 2400 bps on-line. $MB4800 Selects 4800 bps on-line. $MB9600 Selects 9600 bps on-line. $MB14400 Selects 14400 bps on-line. $MB19200 Selects 19200 bps on-line. $MB28800 Selects 28800 bps on-line. $MB33600 Selects 33600 bps on-line.
Command: $SB Serial Port Baud Rate Values: n = speed Default: 115200 Description: $SB300 Selects 300 bps at serial port. $SB1200 Selects 1200 bps at serial port. $SB2400 Selects 2400 bps at serial port. $SB4800 Selects 4800 bps at serial port. $SB9600 Selects 9600 bps at serial port. $SB19200 Selects 19200 bps at serial port. $SB38400 Selects 38400 bps at serial port. $SB57600 Selects 57600 bps at serial port. $SB115200 Selects 115200 bps at serial port.

Certain Command Mode configurations are stored in memory registers called, S-Registers. The S command is used to assign a value to, and to read the current value of an S-Register. To assign a value to an S- Register, enter the letter S, followed by the S-Register number and an equals sign (=). To read an S-Register value, enter the letter S followed by the S-Register number and a question mark (?), then hit RETURN. To verify that the S-Register value was entered correctly, enter for example, ATS8? and hit RETURN. You should receive a response of the assigned value given to that S-Register.
Register: S0 Unit: rings Range: 0, 1–255 Default: 0 Description: Sets the number of rings before the modem answers. ATS0=0 disables auto-answer completely.
Register: S1 Unit: rings Range: 0, 1–255 Default: 0 Description: Counts the number of rings that have occurred.
Register: S2 Unit: decimal Range: 0-127 128-255 Default: 43(+) Description: Sets ASCII code for the escape character. Values greater than 127 disable the escape sequence.
Register: S3 Unit: decimal Range: 0-127 Default: 13(^M) Description: Sets ASCII code for the carriage return character.
Register: S4 Unit: decimal Range: 0–127 Default: 10(^J) Description: Sets ASCII code for the line feed character.

Register: S5 Unit: decimal Range: 0-32, 33-127 Default: 8(^H) Description: Sets ASCII code for the backspacecharacter. Values greater than 32 disable the backspace character.
Register: S6 Unit: seconds Range: 2-65 Default: 2 Description: Sets the time the modem waits after it goes off- hook before it begins to dial the telephone number.
Register: S7 Unit: seconds Range: 1-255 Default: 50 Description: Sets the time the modem waits for a carrier signal before aborting a call. Also sets the wait for silence time for the @ dial modifier.
Register: S8 Unit: seconds Range: 0-65 Default: 2 Description: Sets the length of a pause caused by a comma character in a dialing command.
Register: S9 Unit: ASCII Range: 0-127 Default: 0 Description: Defines Remote Configuration Escape Character.
Register: S10 Unit: 100ms Range: 1-254 Default: 20 Description: Sets how long a carrier signal must be lost before the modem disconnects.

Register: S11 Unit: 1 ms Range: 50-150 Default: 95 Description: Sets spacing and duration of dialing tones.
Register: S28 Unit: decimal Range: 0, 1-255 Default: 1 Description: 0 disables, 1–255 enables V.34 modulation.
Register: S30 Unit: 1 minute Range: 0-255 Default: 0 Description: S30 specifies the length of time (in minutes) that the modem waits before disconnecting when no data is sent or received. This function is only applicable to buffer mode.
Register: S35 Unit: decimal Range: 0-1 Default: 0 Description: 0 disables, 1 enables the V.25 data calling tone, which allows remote data/fax/voice discrimination.
Register: S36 Unit: decimal Range: {0,2}, {1,3}, {4,6}, {5,7} Default: NA Description: This register specifies the action to take in the event of negotiation failure when error control is selected. (See S48.)

Register: S37 Unit: decimal Range: 0-19 Default: 0 Description: Sets the maximum dial line rate. 0 = maximum modem speed 1 = reserved 2 = 1200/75 bps 3 = 300 bps 4 = reserved 5 = 1200 bps 6 = 2400 bps 7 = 4800 bps 8 = 7200 bps 9 = 9600 bps 10 = 12000 bps 11 = 14400 bps 12 = 16800 bps 13 = 19200 bps 14 = 21600 bps 15 = 24000 bps 16 = 26400 bps 17 = 28800 bps 18 = 31200 bps 19 = 33600 bps Register: S42 Unit: decimal Range: 0-1 Default: 1 Description: For testing and debugging only. Enables/disables the V.32bis and V.22bis auto rate. Retrain and fallback are disabled in data mode. 0 = disable; 1 = enable.
Register: S43 Unit: decimal Range: 0-1 Default: 1 Description: For testing and debugging only. Enables/disables V.32bis start-up auto mode operation. 0 = disable; 1 = enable.

Register: S48 Unit: decimal Range: 7 or 128 Default: 7 Description: The following chart lists the S36 and S48 configuration settings necessary to negotiate certain types of connections.

Register: S89 Unit: seconds Range: 0, 5-255 Default: 10 Description: Sets the length of time in the off-line command mode before the modem goes into standby mode. A value of zero prevents standby mode; a value of 1–4 sets the value to 5.

When the modem receives an AT command from the terminal or PC, it tries to execute the command, then sends a status message to the PC or terminal which reports the "results" of the command (hence the name "result codes"). The MultiModemZDX Command mode provides you with several responses, or “Result Codes”, that provide visual responses during Command mode operation. These Result Codes are displayed on your PC's video monitor.
0 OK Command executed 1 CONNECT Modem connected to line 2 RING Ring signal detected 3 NO CARRIER Carrier signal lost or not detected 4 ERROR Invalid command 5* CONNECT 1200 Connected at 1200 bps 6 NO DIALTONE No dial tone detected 7 BUSY Busy signal detected 8 NO ANSWER No answer at remote end 10* CONNECT 2400 Connected at 2400 bps 11* CONNECT 4800 Connected at 4800 bps 12* CONNECT 9600 Connected at 9600 bps 13* CONNECT 14400 Connected at 14400 bps 14* CONNECT 19200 Connected at 19200 bps 24* CONNECT 7200 Connected at 7200 bps 25* CONNECT 12000 Connected at 12000 bps 26* CONNECT 16800 Connected at 16800 bps 40* CONNECT 300 Connected at 300 bps 55* CONNECT 21600 Connected at 21600 bps 56* CONNECT 24000 Connected at 24000 bps 57* CONNECT 26400 Connected at 26400 bps 58* CONNECT 28800 Connected at 28800 bps 59* CONNECT 31200 Connected at 31200 bps 60* CONNECT 33600 Connected at 33600 bps 88 DELAYED Delay is in effect for the dialed number 89 BLACKLISTED Dialed number is blacklisted 90 BLACKLIST FULL Blacklist is full
* EC is added to these Result Codes when the extended Result Codes configuration option is enabled. EC is replaced by one of the following codes, depending on the type of error control connection: V42bis (V.42 error control [LAP-M] and V.42bis data compression); V42 (V.42 error control [LAP-M] only); MNP5 (MNP 4 error control and MNP 5 data compression); MNP4 (MNP 4 error control only); NoEC (No error control protocol).
Terse Verbose Description

Local Analog Loopback Test/V.54 Loop 3
In this test, data from your computer or terminal is sent to your modem's transmitter, converted into analog form, looped back to the receiver, converted into digital form and then received back at your monitor for verification. No connection to the phone line is required. See Figure 4-1.

Figure 4-1. Local Analog Loopback Test
The test procedure is as follows:

The Digital Loopback Test is an on-line test that loops data sent from one modem across the phone line to another modem, then back to the first modem. See Figure 4-2.
There are two ways to put a modem into Digital Loopback mode.
All loopback tests will operate at all speeds except 300 bps. Disable error correction (AT\N0&W0<CR>) before engaging in loopback tests.
In this test the local modem is placed in Digital Loopback mode. Data is entered and transmitted from the remote modem (which is not in digital loopback mode), sent across the phone line to the local modem and looped back to the remote modem.
The test procedure is as follows:
5. Data is typed from the remote keyboard. For this test, typing multiple upper case "U" characters is a good way to send an alternating test pattern of ones and zeros. The data received by the local modem will enter its analog receiver, be converted to digital data, be reconverted into analog, and then looped through its transmitter back to the remote modem. Your modem passes this test if the data entered from the remote keyboard is the same as the data received on the remote monitor.


Figure 4-2. Digital Loopback Test(local/manual)
In this test, your modem must be On-line with another modem set up to respond to a request for Digital Loopback (note that some modems may not support Remote Loopback or may have this feature disabled). The test procedure is as follows:

5. Type data from your keyboard. For this test, typing multiple upper case "U" characters is a good way to send an alternating test pattern of ones and zeros. The data received by the remote modem will enter its analog receiver, be converted to digital data, be reconverted into analog, and then looped through its transmitter back to the local modem. Your modem passes this test if the data entered from the local keyboard is the same as the data received on your monitor.

Figure 4-3. Digital Loopback Test (remote/automatic)

See New Warranty Policy - Multi-Tech Web Site
This chapter starts out with statements about your modem's 10-year warranty (limited to customers in the U.S., Canada, Mexico and the United Kingdom). The next section, Tech Support, should be read carefully if you have questions or problems with your modem. It includes the technical support telephone numbers, space for recording your modem information, and an explanation of how to send in your modem should you require service.
Multi-Tech Systems, Inc. (“MTS”) warrants that its products will be free from defects in material or workmanship for a period of ten years from the date of purchase, or if proof of purchase is not provided, ten years from date of shipment. MTS MAKES NO OTHER WARRANTY, EXPRESSED OR IMPLIED, AND ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY DISCLAIMED. This warranty does not apply to any products which have been damaged by lightning storms, water, or power surges or which have been neglected, altered, abused, used for a purpose other than the one for which they were manufactured, repaired by the customer or any party without MTS’s written authorization, or used in any manner inconsistent with MTS’s instructions.
MTS’s entire obligation under this warranty shall be limited (at MTS’s option) to repair or replacement of any products which prove to be defective within the warranty period, or, at MTS’s option, issuance of a refund of the purchase price. Defective products must be returned by Customer to MTS’s factory transportation prepaid.
MTS WILL NOT BE LIABLE FOR CONSEQUENTIAL DAMAGES AND UNDER NO CIRCUMSTANCES WILL ITS LIABILITY EXCEED THE PURCHASE PRICE FOR DEFECTIVE PRODUCTS.

To register your Multi-Tech product on-line, click on the following link:
http://www.multitech.com/support/register.htm
Multi-Tech has an excellent staff of technical support personnel available to help you get the most out of your Multi-Tech product. If you have any questions about the operation of this unit, call 1-800-972-2439. Please fill out the modem information (below), and have it available when you call. If your modem requires service, the tech support specialist will guide you on how to send in your modem (see Section 5.3.2).
Please fill in the following information on your Multi-Tech modem. This will help tech support in answering your questions.
Modem Model No.:
Modem Serial No.:
The modem model and serial numbers are silkscreened on the bottom of your modem. The software versions are printed on the diskette labels. Type ATI4 to display the modem firmware version. Please note the status of your modem before calling tech support. This screen messages, diagnostic test results, problems with a specific application, etc. Use the space below to note modem status:

If your tech support specialist decides that service is required, modems may be sent (freight prepaid) to our factory. Return shipping charges will be paid by Multi-Tech Systems (within North America).
Include the following with your modem:
If you need to inquire about the status of the returned product, be prepared to provide the serial number of the product sent (see previous section).
Send modems to this address:
MULTI-TECH SYSTEMS, INC.
ATTN: SERVICE OR REPAIRS

Multi-Tech Systems maintains a Bulletin Board Service (BBS) for its customers. The information available via the BBS includes: new product information, product upgrade data, problem solving tips, and a message service for you to leave questions for which you would like additional information. The phone number for the Multi-Tech BBS is (612) 785-3702 or (800) 392-2432 (U.S.A. and Canada).
The BBS can be accessed by any asynchronous modem operating at speeds of 33,600-1200 bps (V.34 and downward compatible) with a setting of word length of 8 bits, 1 stop bit, and no parity.
To log on to the Multi-Tech BBS, perform the following steps:
If you know the file name:

If you don’t know the file name:
When you log on, the BBS will tell you if you have a personal message (mail). At the prompt Would you like to read it now?, type R to read the message. This is the only point at which you can read your mail, since you cannot read any messages from the Message Menu.
The Multi-Tech BBS has no public discussion areas. To leave a personal message, select the Message Menu by typing M at the Main Menu. Type E, then press RETURN to select the Sysop conference. Enter the name of the recipient (or “Sysop”), the subject, and the message text. Press ESCAPE to finish, then type S to save the message and exit. To abort the message at any point, leave any of the fields blank and press RETURN.

When you log on, the BBS will ask if you would like to view the bulletin menu. The bulletins are menu-driven; to read a bulletin, enter its number. You can also access the bulletins by typing B at the Main Menu.
In addition to the BBS, Multi-Tech provides support through CompuServe's Modem Vendor Forum (GOMODEMVEN) under GO MULTITECH. Refer to your CompuServe documentation for special operating procedures.
Multi-Tech is a commercial provider on the Internet, and we retrieve e-mail messages from the following mailboxes on a periodic basis:
mtsmktg@multitech.com Marketing Dept. mtssales@multitech.com Sales Dept. international@multitech.com International Marketing & Sales writers@multitech.com Publications Dept.
If you prefer to recieve support via the internet, you can contact Tech Support via e-mail.
Multi-Tech's presence includes a Web site at:
and an ftp site at:
ftp://ftp.multitech.com
Multi-Tech's fax-back system provides 24-hour access to sales, marketing, and technical literature. Dial 612-717-5888, follow the voice prompts, and request document number 10 for a catalog of available documents.
For convenience, have your fax number handy: From the catalog of available documents, you can order newsletters, white papers, press releases, etc. from the sales and marketing index (pages 1-4), or order basic modem operation and troubleshooting guides from the technical support and engineering index. Just enter the applicable FB Doc. # from the left column of the catalog.

Your MultiModemZDX meets the following specifications:
Model Numbers MT3334ZDX, and MT3334ZDXV
Data Rates (modem) 33,600, 31,200, 28,800, 26,400, 24,000, 21,600, 19,200, 16,800, 14,400, 12,000, 9600, 7200, 4800, 2400, 1200, 0-300 bps
Data Rates (fax) 14,400, 9600, 7200, 4800, 2400 bps
Data Format Serial, binary, asynchronous at 75-300, 1200, 2400, 4800, 7200, 9600, 14,400, 16,800 or 19,200, 21,600, 24,000, 26,400, 28,800, 31,200, 33,600 bps
Compatibility ITU V.42bis, V.42, Enhanced V.34, ITU V.32bis, V.32, V.21, V.22bis, V.22, V.23, ITU V.17, Group 3 T.4, T.30 and EIA TR- 29 Class 2
Fax Compatibility ITU-T V.17, Group 3, V.29, V.27ter and EIA TR-29 Class 2
Voice Compatibility IS-101 AT+V command compatible (MT3334ZDXV only)
Error Correction/ V.42 (LAP-M or MNP 3 & 4),
Data Compression V.42bis, (4:1 throughput), MNP 5 (2:1 throughput)
Speed Conversion Serial port data rates adjustable to 300, 1200, 2400, 4800, 9600, 19,200, 38,400, 57,600 and 115,200 bps
Flow Control Xon/Xoff, Hardware RTS/CTS, ENQ/ACK
Mode of Operation Fax On-line modes, and “AT” command modes supporting Full duplex over dial- up lines, "+V AT" (for MT3334ZDXV only) Answering Machine and Voice Mail functions
Tradename MultiModemZDX

Intelligent Features Automatic or manual dialing, Automatic or manual answer, Microprocessor- controlled, remote configuration, EIA extended Automode, adaptive line probing, automatic symbol rate and carrier frequency during start-up, retrain and rate renegotiation, DTMF detection, Autodial, Redial, Repeat dial, Dial linking, Tone dial, Dial pauses, Call status display, Auto-parity and data rate selection, Keyboard-controlled modem options, Nonvolatile memory and on-screen displays for modem option parameters and two telephone numbers/command lines of up to 60 digits each, Help menus
Command Buffer 60 characters
Data Modulation Trellis Coded Modulation (TCM) at 33,600, 31,200, 28,800, 26,400, 24,000, 21,600, 19,200, 16,800, 14,400, 12,000 and 9600 bps, Quadrature Amplitude Modulation (QAM) at 9600 (non-trellis), 4800 and 2400 bps, PSK at 1200 bps, FSK at 300 bps
Fax Modulation V.17 TCM at 14400, 12000, 9600, and 7200 bps V.29 QAM at 9600 and 7200 bps V.27ter DPSK at 4800 and 2400 bps V.21CH2 FSK at 300 bps (Half Duplex)
Carrier Frequencies 1800 Hz V.32/V.32bis/Enhanced V.34/ 33.6K/31.2K/28.8K/26.4K/24K/21.6K/ 19.2K/16.8K/14.4K/12K/9.6K/4.8K
Voice Compression PCM 128, 8000 kHz or and Sampling Rate IMA ADPCM 8000 kHz (selectable via +V commands). Note that your computer system should have a processing speed of at least 75 MHz to take full advantage of the telephony features of this product.
Appendices

Carrier Frequencies Transmit Originate: 1200 Hz 2400 & 1200 bps Transmit Answer: 2400 Hz (V.22bis/V.22) Receive Originate: 2400 Hz Receive Answer: 1200 Hz
V.21 980 Hz Mark, 1180 Hz Space for Transmit Originate 1650 Hz Mark, 1850 Hz Space for Transmit Answer 1650 Hz Mark, 1850 Hz Space for Receive Originate 980 Hz Mark, 1180 Hz Space for Receive Answer
V.23 390 Hz Mark, 450 Hz Space for Transmit Originate 1300 Hz Mark, 2100 Hz Space for Transmit Answer 1300 Hz Mark, 2100 Hz Space for Receive Originate 390 Hz Mark, 450 Hz Space for Receive Answer
Transmit Level -11dBm (dial-up)
Frequency Stability ±0.01%
Receiver Sensitivity -43 dBm under worst-case conditions
AGC Dynamic Range 43 dB
Carrier Frequencies · Carrier Frequencies Fax

Interface EIA RS232C/CCITT V.24
Connectors DB25 (RS232C) connector; Two RJ11 modular phone jack: for line, and telephone set, power jack.
Diagnostics Power-on Self Test, Local Analog Loop, Local Digital Loop, Remote Digital Loop.
Indicators LEDs for Send Data, Receive Data, Carrier Detect, various speed indicators, Off Hook, Terminal Ready, Error Correction, Fax.
Controls Power ON/OFF Switch
Speaker Speaker with software- or command- controlled volume.
Operating 0° to 50° C Temperature
Power Requirement 115 Volts AC, 60 Hz, .3 amp (2-prong outlet-mounted transformer); 240V/50Hz optional (international)
Power Consumption 5 Watts
Dimensions 14.8 x 10.8 x 2.9 cm (L x W x D)
Limited Warranty Five years
Appendices · Weight 224 grams

1 2 3 A
4 5 6 B
7 8 9 C
0 # D *
Hz 1209 1336 1477 1633
The tone-dialing method combines two frequencies for each of the twelve digits found on a Touch Tone dial pad. This method is referred to as Dual- Tone Multi-Frequency (DTMF) dialing. The four horizontal rows on a Touch-Tone keypad use the four low frequencies (697, 770, 852, 941 Hz), while the three vertical columns use the three high frequencies (1209, 1336, 1477 Hz). The generally accepted tone frequency tolerance is +0.02%.
For example, the digit 4 would be dialed by combining two tone frequencies. It would use the frequency 770 Hz from the second row, and the frequency 1209 Hz from the first column. In another example, the digit 9 would be dialed with the tone frequencies of 852 Hz and 1477 Hz.
The extended DTMF characters (A, B, C, D) are the high-end frequencies (1633 Hz) defined on some telephone sets with a fourth vertical column of buttons. This fourth column provides for extended PBX control functions; the actual functions provided are dependent on the PBX manaufacturer's implementation and feature set.
Hz Digits

Multi-Tech Web Site Publishes Current Regulations
An FCC-compliant telephone cord and modular plug is provided with this equipment. This equipment is designed to be connected to the telephone network or premises wiring using a compatible modular jack which is Part 68 compliant. See installation instructions for details.
3. The ringer equivalence number (REN) is used to determine the quantity of devices which may be connected to the telephone line. Excessive REN’s on the telephone line may result in the devices not ringing in response to an incoming call. In most, but not all areas, the sum of the REN’s should not exceed five (5.0). To be certain of the number of devices that may be connected to the line, as determined by the total REN’s, contact the telephone company to determine the maximum REN for the calling area.
Appendices

Manufacturer: Multi-Tech Systems, Inc. Model Numbers: MT3334ZDX, MT3334ZDXV FCC Registration #: AU7USA-31068-MME Ringer Equivalence: 0.4B Modular Jack (USOC) RJ11C or RJ11W (single line) Service Center in USA: Multi-Tech Systems Inc. 2205 Woodale Drive Mounds View, MN 55112 Voice (612) 785-3500/ FAX (612) 785-9874

NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a residential installation. This equipment generates, uses and can radiate radio frequency energy, and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit different from that of which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
The Telephone Consumer Protection Act of 1991 makes it unlawful for any person to use a computer or other electronic device to send any message via a telephone fax machine unless such message clearly contains in a margin at the top or bottom of each page or the first page of the transmission, the date and time it is sent and an identification of the business or other entity, or other individual sending the message and the telephone number of the sending machine or such business, other entity, or individual. See the cover page of your fax software manual for setup details.
This device complies with Part 15 of the FCC rules. Operation is subject to the following conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.
Appendices

Notice: The ringer equivalence number (REN) assigned to each terminal device provides an indication of the maximum number of terminals allowed to be connected to a telephone interface. The termination of a interface may consist of any combination of devices subject only to the requirement that the sum of the ringer equivalence numbers of all the devices does not exceed 5. The ringer equivalence number for this product is 0.2.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.

Approved for connection to telecommunications system specified in the instructions for use subject to the conditions set out in them.
This apparatus has been approved for the use of the following facilities:
When correctly installed and maintained, the modem will present no hazard to the user. When correctly installed the modem will be connected to the PSTN or a PW and to a Data Terminal Equipment (DTE), whose modem connections comply with ITU recommendation V28. The DTE connections are therefore taken to be safe voltages (less than ± 30 volts).
The main power source shall be installed near to the equipment and shall be easily accessible. The plug that connect to the apparatus to the main power supply must be fitted with a 5A fuse that complies with BSI1362.
Ports which are capable of connecting to other apparatus are defined as SELV. To ensure conformity with EN41003, ensure that these ports are only connected to ports of the same type on other apparatus.
Appendices

a. The modem is suitable for connection to the Public Switched Telephone Network (PSTN) provided by British Telecommunications plc or Kingston Communications (Hull) plc. Circuit supply by British Communications, Mercury Communication, or Hull City Council. Only direct exchange lines may be used, not shared service.
b. The modem is suitable for household, office, and similar general indoor use. It is not suitable for use as an extension to a payphone.
c. BT lines supplied must support either loop disconnect or multifrequency tone signalling.
d. REN (Ringer Equivalence Number).
The REN value of a unit is calculated from 3/n where n is the total number of units which can be connected in parallel which will still cause the standard bell (as defined in BS6305 Appendix D) to ring.
REN values of less than 0.3 cannot be assigned.
If a telephone or other device is connected in parallel with the modem, the combined REN must not exceed 4. A BT supplied telephone may be assumed to have REN of 1.0 unless otherwise noted.
The approval of this modem for connection to the British Telecom public switched telephone network is INVALIDATED if the apparatus is subject to any modification in any material way not authorized by BABT or if it is used with or connected to:
i. internal software that has not been formally accepted BABT.
ii. external control software or external control apparatus which cause the operation of the modem associated call set-up equipment to contravene the requirements of the standard set out in BABT/SITS/ 82/005S/D.
All other apparatus connected to this modem and thereby connected directly or indirectly to the British Telecom public switched telephone network must be approved apparatus as defined in Section 22 of the British Telecommunications Act 1984.
The REN number for this apparatus = 1

a. The modem is not capable of allowing Auto Call using '999' or other PABX emergency numbers.
b. Modes other than modes 1, 2, or 3 should not be used on the BT PSTN. This modem is a mode 1 device.
c. Users are advised to check the numbers entered during the Auto Call set up phase prior to dialing.
d. The user should not issue any sequence of commands to the modem which would cause the modem to exceed the maximum allowable pause of 8 seconds from the time the modem goes off hook until dialing begins.
e. For correct operation of the call progress monitor, the power has to be properly connected and switched on.
a. The modem is not suitable for use on circuits with British Telecommunications signaling at a normal frequency of 2280 Hz.
b. The modem does not require signaling or otherwise employ the frequency range dc to 200 Hz.
c. The modem may be connected to a point to point two-wire or four- wire Private Circuit.
d. The modem does not require dc from the Private Circuit for correct operation. The modem may be damaged if connected, in a private circuit mode, to a circuit supplying dc current (the maximum permissible direct current is zero amps).
Appendices

The CE mark is affixed to the enclosed Multi-Tech product to confirm compliance with the following European Community Directives:
Council Directive 89/336/EEC of 3 May 1989 on the approximation of laws of Member States relating to electromagnetic compatibility;
Council Directive 73/23/EEC of 19 February 1973 on the harmonization of the laws of Member States relating to electrical equipment designed for use within certain voltage limits;
Council Directive 93/68/EEC of 22 July 1993 on the harmonization of CE marking requirements.
Modems connected to the Australian telecommunications network must have a valid AUSTEL permit. This modem has been specifically configured to ensure compliance with AUSTEL Standards. The following commands can affect compliance and must not be set outside the acceptable range.
Modem Commands:
Command Default Permissible Range A: - Do not use ATB B0 Do not change AT&G &G2 Do not change AT&P &P1 Do not change ATSn see table below
S-Register Default Permissible Range S6 4 2 - 5
and · both amended by

Call Attempts/Retries:
Applications software shall be configured so that no more than 3 attempts are made to establish a connection to a given number (Note: if the modem can detect service tones, up to 10 attempts can be made). There must be at least 2 seconds between call attempts. If the call sequence is unsuccessful, there shall be a delay of at least 30 minutes before attempting to call the number again.
Failure to set the modem, and any communications software used with the modem, to the values shown above will result in the modem being operated in a non-compliant manner. Consequently, there would be no permit in force for this equipment, and the Telecommunications Act 1991 prescribes a penalty of $12,000 for the connection of non-permitted equipment.
For Voice Modems:
“Distortion may be generated because of low bit rate voice, and reduced voice quality may result.”
Refer to the applicable MultiModemII Owner’s Manual for additional information.
Protection Against Contact with TNV Circuit (Internal PC Cards)
The protective cover is fastened to the modem card by means that will only allow a tool to remove the cover. “Warning: removal of the protective cover will render the AUSTEL permit void.”
“Use of pulse dialing, when this equipment is connected to the same line as other equipment, may give rise to “bell tinkle” or noise and may also cause a false answer condition. Should such problems occur, the user should NOT contact the Telecom Faults Service.”
“The preferred method of dialing is to use DTMF tones, as this is faster than pulse (decadic) dialing and is readily available on almost all New Zealand telephone exchanges.”
“WARNING NOTICE: No ‘111’ or other calls can be made from this device during a mains power failure”.
Appendices

Compression, data 6 CompuServe/Internet 51 Connection 22 Connectors 55 Controls 55
Data 6 Carrier Detect (DCD) Control 31 Compression 52 Compression Control 34 Features 6 Format 52 Modulation 53 Data Rates (bps) 52 Data Set Ready (DSR) Control 33 Data Terminal Ready (DTR) Control 32 Datacomm software 6, 20 DB-25 Connector 5 DB-9 Connector 5 Diagnostics 55 Dial Command 28 Dimensions 55 Downloading a File 49
Echo Command Mode Characters Command 28 Echo Online Data Characters Command 29 Enable/Disable Result Codes 30 ENTER or Carriage Return Key 27 Error Correction 14, 52 Mode Selection 34 European Low Voltage Directive 61 Extended DTMF Characters 56
Index

Fall-forward 6 Fallback 6 Fax 6, 7 Command set 7 Features 7 Transmission speeds 7 Fax Modulation 53 Fax-Back Service 51 FCC Regulations 57 Flow Control 52 Flow Control 25 Frequency Stability 54 Front Panel 19
Garbage Characters 26 Guard Tone Control 32
Hardware/Software Confirmation 18
Indicators 55 Information Request Command 29 Initialization Strings 20, 22 Installation 9 Intelligent Features 53 Interface 55 Internet 51
Kingston Communications (Hull) 62

Leaving a Message 50 LED Indicators 12 LEDs 19 Limited Warranty 46, 55 Line Feed Character (S4) 36 Load Factory Default Settings 32 Logging on to the BBS 49 Long Space Disconnect 31 Losing Data 25
MNP 5 25 Data compression 6 MNP error correction 6 Mode of Operation 52 Model Number 52 Modem Cannot Connect When Answering 24 Modem CE Mark EMC and Safety Compliance 64 Modem Disconnects While Online 24 Modem Does Not Respond to Commands 20 Modem Reset 31 Modulation Handshake 30 Monitor Speaker Mode 29 Monitor Speaker Volume Command 29 MT5634ZDXv Connections 9, 11 MT5634ZDXv Initialization setup 17 Multi-Tech BBS 49 MultiExpress for Windows 23, 24
On-hook/off-hook 29 On-Hook/Off-Hook Control 29 Operating Temperature 55
Index

Pause, Dialing 37 Power Requirements 55 Power Supply 10, 19 Protocol Result Code 34 Protocols 25
Read Register Value 30 Reading a Message 50 Receive Data 12 Receiver Sensitivity 54 Repeat Last Command 27 Result Code Selection 31 Result Codes 22 Return Character (S3) 36 Return Online to Data Mode 30 Ringer Equivalence Number 62 RS-232 5
Select Stored Configuration for Hard Reset 33 Serial Cable 20 Serial Port 21, 25 Set Break Control 34 Set Register Value 30 Software User License Agreement 47 Speaker 55 Speakerphone 7 Speed Conversion 52 Speed, transmission
Data 6 Fax 7 Store Current Configuration 33 Store Telephone Number 33

Telephone line 5, 22 Terminal mode 20 Terse/Verbose 41 Result Code Format 30 Test Commands 33 Testing 19, 22 Self-test 19 Tradename 52 Transmit Data 12 Transmit Level 54
UARTs 25 16550 25
V.22 mode 27 V.22bis Guard Tone command 32 V.42 error correction 6 V.42bis data compression 6 View Current Configuration Command 33 Voice 7 Command set 7 Features 7 Voice Compatibility 52 Voice Compression 53 Voice Compression and Sampling Rate 53
Warranty 10, 46 Weight 55 Windows 3.1 25 serial port driver 25
Xmodem 25
Index
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.