
Home Smart Center
MODEL: ML-001 / ML-100
TM
CUSTOMER SERVICE 17 Sheard Avenue, Brampton, Ontario, Canada L6Y 1J3 Tel : (905) 456-8883 Fax : (905) 456-7819 Email : support@skylinkhome.com
P/N. 101Z379-001 FEB, 2011
®

Home Smart Center
USER'S INSTRUCTIONS

When using your telephone equipment, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following:
Attention
This product is not an alarm system providing facilities to summon assistance, for use by persons who can be considered to be living at risk. This product is not intended to for use in health care signaling equipment or directly connect to central-station (Police, Medical, Fire).

Declaration of Conformity
‘’This product meets the applicable Industry Canada technical specifications.”
Application of Council Directive(s) :
Radio Equipment and Telecommunication Terminal Equipment
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local telecommunications com- pany. The equipment must also be installed using an acceptable method of connection. In some cases, the company’s inside wiring associated with a single line individual service may be extended by means of a certified connector assembly (telephone extension cord). The customer should be aware that compliance with the above conditions may not prevent degradation of service in some situations.
Directive (1999/5/EC) - R&TTE
Standard(s) to which Conformity is Declared:
EN 55022:1998+A1: 2000, EN 610000-3-2: 2000,
EN 61000-3.3: 1995 +A1:2001, EN 55024: 1998+A1: 2001,
Safety:
Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to disconnect the equipment.
Telephony:
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone lines and internal metallic water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.
36 Au Pui Wan Street, Fo Tan, N.T., Hong Kong
Model No.: AM-002
Serial No.: Not Labelled
‘’The Ringer Equivalence Number is an indication of the maximum number of terminals allowed to be connected to a telephone inter- face. The termination on an interface may consist of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not exceed five.’’
I, the undersigned, hereby declare that the equipment specified above conforms to the above
Directive (s) and Standard(s).
Joe Ng Project Manager



Consumer Information:
Overview
a) This equipment complies with Part 68 of the FCC rules and the require- ments adopted by the ACTA. On the bottom of this equipment is a label that contains, among other information, a product identifier in the format US:AAAEQ##TXXXX. If requested, this number must be provided to the telephone company.
Congratulations on your purchase of a Home Smart Center. This is a security control panel which not only functions as a security system, but also monitors your premises by giving you alert notification when the system is not armed. It is also a home automation center, which allows you to remotely control house- hold appliances and lights, even when you are away from home. It can be controlled by dialing in from any touch tone phone, which makes it even more convenient and powerful. Additional accessories such as different kinds of sensors and controllers can be added to suit your specific needs. This user instructions will guide you through the whole setup procedure as well as all the programming instructions. Please follow the instructions closely, you should find it very easy to set up the system.
b) An applicable certification jacks Universal Service Order Codes (USOC) for the equipment is provided (i.e., RJ11C) in the packaging with each piece of approved terminal equipment.
c) A plug and jack used to connect this equipment to the premises wiring and telephone network must comply with the applicable FCC Part 68 rules and requirements adopted by the ACTA. A compliant telephone cord and modular plug is provided with this product. It is designed to be connected to a compatible modular jack that is also compliant. See installation instructions for details.
Alert When Home (System Not Armed)
Alarm Not Home (System Armed)
d) The REN is used to determine the number of devices that may be con- nected to a telephone line. Excessive RENs on a telephone line may result in the devices not ringing in response to an incoming call. In most but not all areas, the sum of RENs should not exceed five (5.0). To be certain of the number of devices that may be connected to a line, as determined by the total RENs, contact the local telephone company. [For products approved after July 23, 2001, the REN for this product is part of the product identifier that has the format US:AAAEQ##TXXXX. The digits represented by ## are the REN without a decimal point (e.g., 03 is a REN of 0.3). For earlier products, the REN is separately shown on the label.]
Zone 1 Sensor 1 Triggered
In the package, you should find the following items:
e) If this equipment AM-002 causes harm to the telephone network, the telephone company will notify you in advance that temporary discontinu- ance of service may be required. But if advance notice isn’t practical, the telephone company will notify the customer as soon as possible. Also, you will be advised of your right to file a complaint with the FCC if you believe it is necessary.
WD-101
operations or procedures that could affect the operation of the equipment. If this happens the telephone company will provide advance notice in order for you to make necessary modifications to maintain uninterrupted service.
Beep Beep · Alarm

INTRODUCTION
Secondary Password ____________________
Duress Password ____________________

(4B-101 -installed) - 2 PCS 3V Lithium Battery CR-2032

Ball-head joint (For ML-100A Only)

Mounting Plate (For ML-100A Only)
Control Modules settings



Control Module SW-100 (US and Canada) - To turn home appliances / lights on / off - Max rating: 960W (Resistive)

Control Module SW-101U (UK), SW-101F (French), SW-101G (German) (3 models for 3 countries) - To turn home appliances / lights on / off
Emergency Dialer (AD-433S) - External dialer with user programmable voice message - Calls up to 9 phone numbers - One personal voice recording up to 40 seconds - Can be installed anywhere within 100 feet from the control panel, with a phone socket
Swing door opener (DM-100) - Remotely open / close a swing door - Fits most interior doors
905-608-9223

INSTALLATION
Audio Sensor (AS-101) - When audio level exceeds preset limit, it will trigger the alarm - Place beside smoke detector, CO detector, so when these detectors are triggered, the control panel will be triggered
It is important determine where the control panel will be located. Please follow the criteria below to select the ideal location for the control panel.
- Place it where electrical outlet and phone line can be accessed - Place it where it is easily accessible by the users - Place it away from any doors or windows which could be accessed by non-intended users - Place is away from extreme temperature sources such as oven, stove and away from large metal objects which could affect the wireless performance
Remote Control (4B-101) - Additional keychain remotes for other family members - To arm, disarm or trigger the panic alarm with this remote
After a location has been selected, you may begin the installation and connect all the necessary wires and power up the unit.
Keypad Control (KP-434) - External keypad control - To arm, disarm or trigger the the panic alarm with this remote - Ideal mounting locations include upper floor, backdoor, or garage
Wrist Watch Style Panic Remote (HW-101) - Activate the panic alarm instantly with this remote - Wear it as a watch - Splashproof design, can be worn during showering

Panic Transmitter (PT-101) - Activate the panic alarm instantly with this remote - Wear it as a pendant - Splashproof design, can be worn during showering
Audio Alarm (AA-433) - External Siren - Powered by AC adapter with backup battery
® · ®

ACCESSORIES
Additional sensors and transmitters as well as add on accessories are available to work with your system.
Connect the 2 wires to the battery. Red wire connects to the “+” terminal on the battery. Black wire connects to the “-” terminal on the battery. Markings on the battery should face up.
Door/Window Sensor (WD-101) - Magnetic Contact Sensor - For all doors or windows - Batteries included
Plug in the wire from the battery to the battery socket inside the battery compartment.
Repeater (RP-434) - Extend the operation range between 2 wireless devices, such as any sensors and control panel - Doubles the operation range automatically between sensors and control panel
Water Sensor (FS-101) - Alerts you when water is detected - Ideal for water detection in basement, under the sink, even bathroom
TM Sensor (GS-101) (Available in US and Canada) - Monitors your garage door - Alerts you when the garage door is left open
TM Sensor (GS-102) (Available outside US and Canada) - Monitors your garage door - Alerts you when the garage door is left open
Indoor/Outdoor Motion Sensor (PS-101) - Monitors area in a 110 degree ARC and up to 40 feet away from the sensor
(Optional) · 7-1/8"

INSTALLATION
Sensors
Master Password can be used for programming, arming, disarming the system, and telephone access. The default Master Password is [1234].
Secondary Password can be used for arming, disarming the system, and telephone access. Secondary Password cannot be used for programming. The default Secondary Password is [0000].
Duress Password is used when you are forcibly compelled to disarm the control panel. Entering the duress password will stop the siren from sounding but the control panel will silently call the emergency phone numbers for help. The default Duress Password is [3838]. You should definitely change this password and let all the users know this password.
It is strongly recommended to change all 3 passwords when you first set up the system.
In order to change the password, follow the procedures below.

TROUBLE SHOOTING
Control Panel
You can program up to 6 Emergency Phone Numbers. When the system is in panic, the control panel will call these phone numbers and announce its status.
The 6 emergency phone numbers include: - 5 voice message phone numbers - 1 Contact ID message phone number
Program the following for Voice Message Phone Numbers - Phone memory (from 1 to 5), this is where the phone numbers will be stored - Phone number, up to 29 digits. - Redial count, this is how many times that phone number will be called, from 1 to 9 times. - Repeat count, this is how many times the emergency message will be repeated, from 1 to 9 times.
**Note: You may enter a 3-second pause between digits by pressing [Mute] if needed. You may also enter consecutive multiple pause periods. For example, you may enter a phone number: (123)-456-7890 [Mute] 1234. After the phone number (123)-456-7890 is dialed, it will wait for 3 seconds, then dial 1234, which can be a password to a paging system, or an access code for a phone dialing system.

INSTALLATION
Note: - It’s not recommended to program 911, fire station or any emergency services phone numbers into any of the phone memories without their approvals. - Ensure to program a valid phone number and write down the programmed phone number on the System Setting Information provide on the back of this user's instructions. - You may quit programming by pressing [PROG] button at any time. - If no phone number is programmed, the ARM LED will continue to flash.

Press once will enable “Event Trigger On”, press again will enable “Event Trigger Off”. This row of buttons operates in toggle manner, between event trigger on and event trigger off.
After you have programmed all the phone numbers, you should verify you have programmed the phone numbers correctly. This can be done by triggering the alarm silently by entering the duress password, so it dials to the programmed phone numbers without sounding the alarm.

Note: You must inform the recipients of the programmed phone numbers, so they know what to expect when they receive the phone call from the control panel during an emergency. These recipients should know the password to your control panel if you expect them to have remote access of your control panel. For more informa- tion regarding receiving the emergency call, please refer to page 26.
1. Press [Arm], you should hear beeping from the control panel. 2. Press [3838]. Beeping will stop, and the control panel will start to dial the first number. 3. The called party should receive the call. Pick up the call and say “Hello”, an emergency message “System Panic” will be played. If the programmed phone doesn’t ring, ensure the phone number is programmed correctly, or reprogram this phone number again. 4. After the emergency message has been played for several times (depending on how many times it was programmed), the called party will hear “Enter Password”. 5. Enter either the master password or secondary password. If the correct password is accepted, you will hear “Password Accepted”, otherwise, you will hear “Password Failure”. 6. Press [0][#] on the telephone to hang up. 7. The control panel will start to dial the next programmed phone number.
to an emergency call. - The password is treated as a confirmation of the emergency message. Once a
valid password is entered, the control panel will not call that number again, it will proceed to the next number. - If any one of the called parties disarms the control panel, the control panel will
not continue to dial the remaining phone numbers. - After calling all the programmed phone numbers, the control panel will be back
to the previous operation mode.

HOME AUTOMATION
Contact ID Phone number
You can program a telephone number for calling to the central monitoring station. When the system is in panic, the control panel will call this phone number and will send out a Contact ID message with event code 140, which represents “General Alarm”.
You can control up to 5 different devices not only manually, but also automatically. It is called Event Trigger. That means when a sensor is triggered, the control panel will transmit a signal to activate the designated control module. Applications include:
Follow the instructions below to program the necessary info in order to call a monitoring station:
(walking into a room, lights on automatically), this is called "Event Trigger on".
- Phone number of central monitoring station (up to 29 digits) - Account number given by the Central Monitoring Station
from a room, turns lights off), this is called "Event Triggered off".
Event trigger is only applicable to the sensor(s) and control module in the same zone. For example, you can program control module 1 to be on or off when zone 1 sensor(s) is triggered. You can also program control module 2 to be on / off when zone 2 sensor(s) is triggered.

Factory Default: This feature is disabled for all zones at the factory.
Press [0] You will hear [Phone Zero] Enter phone memory
To change the event trigger setting follow the instructions below.
During emergency, the Contact ID phone number has the highest priority, it will be the first number to call.

You will hear [Phone Accepted] indicating the phone number has been programmed successfully.
After [7] is entered, some zone LEDs will be off, on or flash. This indicates the setting of event trigger.
Select which zone you would like to enable / disable event trigger.
Refer to the diagram below to select the appropriate setting.
If event trigger “ON” is enabled, that zone LED will be on. If event trigger “OFF” is enabled, that zone LED will flash. If it is disabled, the zone LED will be off. You are allowed to make multiple changes before terminating programming mode.
Event Trigger On · Event Trigger Off

INSTALLATION
In order to program the account number, follow the procedures follow:
Off Zone is not occupied by any control module
Flashes twice That means a remote has occupied that zone. THIS IS NOT A CONTROL MODULE, THEREFORE, SHOULD NOT BE ERASED.
Press [PROG] Press [MPIN]
Flashes once That zone is occupied by a control module. You may select this zone to erase this control module.
Flashes once, That means this zone is occupied by a remote AND a control module. then twice You may select this zone to erase the control module.
Press [0] Select to add / change account number
[0] = Add/change account number
** Table F: Zone LED status for erasing control module.
Enter [New 4- digit Account Number]
Enter new account number
Enter the 4-digit account number given by the central monitoring station.
This number can be a combination of 0-9, B,C,D,E & F.
Part 2 Erase communication from Control Panel to Control Module
To enter 0-9: Enter by the keypad 0-9 directly.
Remove the control module from the electrical outlet
To enter B,C,D,E,F: Press [STATUS] and the ARM light will stay on. Then press the following keys for the correspond- ing letters (1=B, 2=C, 3=D, 4=E, 5=F).
2 To erase the memory of the control module
Press and hold the learn button on the control module while plugging in the control module to an electrical outlet.
Control module LED will flash rapidly indicating all the memory is erased. You may now release the learn button.
Press [STATUS] to return back to number-mode when you want to input numbers. The ARM light will turn off.
You can toggle between the number or letter mode by pressing [STATUS] when entering the account number.
Once the memory of the control module is erased, all of its memory is cleared. If you have other remotes / control panels controlling this control module, you need to re-program those remotes / control panels.
5 3 beeps if new account number is accepted. You will hear [Password Accepted]
Enter [New 4- digit Account Number]
Enter the new account num- ber again for confirmation
Enter Programming mode · Press [2] · Select password programming

HOME AUTOMATION
To turn off a light with the control panel: 1. Press the device number button on the control panel, i.e. pressing 1 will turn off device 1, pressing 2 will turn off device 2. 2. You will hear [Device X Off], where X is the device number. 3. You will also see the PROG LED flashing, indicating the control panel is sending out the wireless signal to control the specific device. 4. If the receiver receives the signal, the control panel will announce [Device Off Accepted].
You can deactivate the digital dialer by erase the phone number memory for central monitoring station.
Press [PROG] Press [MPIN]
To turn on a light with the control panel: 1. Press the number below the device number that you would like to turn on, i.e. pressing 6 will turn on device 1, pressing 7 will turn on device 2. 2. You will hear [Device X On], where X is the device number. 3. You will also see the PROG LED flashing, indicating the control panel is sending out the wireless signal to control the specific device. 4. If the receiver receives the signal, the control panel will announce [Device On Accepted].
Select phone number programming
Press [0] Enter phone memory
Press [ARM] You will hear [Phone Zero Empty Memory] indicating the phone number have been deleted, the digital dialer is deactivated.
Confirm delete the phone number.
To erase a control module from the control panel, it is similar to learning a control module, which involves 2 parts.
Part 1 Erase the memory of the Control Panel
[0] Select erase control module programming
After [0] is entered, some zone LEDs will flash or stay off. The zone LEDs represent whether that zone is occupied by any control module. **See Table F
To erase an occupied control module, press [1] to [5].
Select the control module location you would like to erase
Refer to the table below to select the control module location.
After you have selected the remote location, you will hear 3 beeps and verbal confirmation [Device X Empty Memory], where X is the control module location you have selected.
Enter Program- ming mode · Press [1] · Enter Programming mode

INSTALLATION (ML-100A Only)
Control Module [1] is represented by zone LED 1

Window / Door Sensor is used to monitor doors or windows that open and close. When these doors / windows are open or closed, the sensors will transmit a signal to the control panel to notify the user. These sensors consist of 2 parts, one is the transmitter, the other is the magnet.
Before installing the sensor, remove the battery isolator by pulling out the yellow tab. Once the isolator is removed, the corresponding zone LED on the control panel will flash and buzzer will beep. If the magnetic contact is closed, the beeping will stop.
Part 2 Learn signal from Control Panel to Control Module
Zone 1 Sensor 1 and Zone 2 Sensor 1. Trigger the sensor and listen to the beeping and zone LED to determine which one is zone 1 and which is zone 2.
Press and hold the learn button on the Control Module until its LED starts to flash.
LED on the Control Module will flash indicating it is in learn mode.
The transmitters should be mounted on the door frame or window frame by double sided tape. The magnet should be mounted on the door or window by either double sided tape or screws. Make sure the magnet is aligned with the red marking on the transmitter. If the surface of the frame is flat enough, double- sided foam tape is sufficient, otherwise, it is recommended to screw the mounting plate to the frame, then apply double sided tape. After mounting the sensor, if the AAA+ logo is inverted, remove the front cover and rotate it so the AAA+ logo is in the upright position.
[6] to [0] Transmit an ON signal for the selected device from the Control Panel to the Control Module.
Refer to the chart below to determine which button [6] to [0] to press. You should transmit the “ON” command for the selected device.
After [X] is entered, you will hear [Device X On] indicating you have trans- mitted an ON signal for device X, where X is the Control Module Location. The LED on the Control Module should be off, indicating it has learned the signal, you may now release the learn button and the LED will stay on again.
Sensor Magnet on the left Magnet on the right
Double-sided foam tape Mounting plate and screws (optional)
TRANSMIT BUTTON [X]
Testing: After mounting the sensor, test the sensor by opening and closing the door or window. Open the door or window will result in the followng:
Transmitter · Magnet · Enter Programming mode

HOME AUTOMATION

Part 1 Learn signal from Control Module to Control Panel

After [4] is entered, some zone LEDs will flash or stay off. The zone LEDs represent whether that zone is already occupied by another control module.**See Table E.
damaging them. Mounting the sensors at a higher position will also result in better operating range.
[1] to [5] After you have selected the control module location, that zone LED will be on.
Select the location [1], [2], [3], [4], or [5].
- Do not mount the sensor to the exterior of the door / window, always mount the
sensor to the interior side of the door / window to avoid being damaged or stolen by non-intended users.
Activate the control module by pressing its learn button once quickly.
Once the signal is transmitted to the Control Panel, that signal will be stored.
You will hear [Device X Accepted], where “X” is the control module location.
The motion sensor is most suitable for guarding a large area such as living room, family room, or bedroom. It can also be used to monitor a hallway or stairway.

Undo the screw on the back of the motion sensor and remove the battery cover. Connect a 9V alkaline battery to the battery connector. Please note the polarity.
Off Zone is not occupied by any control module
Flashes once This zone is occupied by another control module. Programming another remote to this zone will overwrite the previous control module.
If you are planning to install the motion sensor outdoor, you should reduce the sensitivity by placing the jumper at location “2”. For indoor application, if you want to reduce the sensitivity, you can change the jumper setting to “2” as well.
Flashes twice This zone is occupied by a remote. You can still program a control module to this zone, and it will not overwrite the remote you have in this zone.
Flashes once, This zone is occupied by a remote AND a control module. If you then twice program another control module to this zone, it will overwrite the previous control module, but not the remote.
Caution: Depending on the environment, if you experience a false trigger when the motion sensor is placed outdoors, you should relocate it or even place it indoors. Wind blowing at a tree, or direct sunshine could cause a false trigger. Therefore, if the location at where the motion sensor is mounted could cause a false trigger, you should change the mounting location for such sensor.
** Table E: Zone LED status for learning control module.
Sensitivity

INSTALLATION (ML-100A Only)
The Control Panel can be used to control lights and home applicances with a Control Module, (Control Module is sold separately). Garage door opener can be controlled with a Garage Door Receiver (sold separately). The Control Panel can control up to 5 Control Modules / Garage Door Receivers.
For outdoor monitoring, please refer to page 33 to program the motion sensor to Alert Zone.
You may now close the battery cover and re-insert the screw. Mount the ball-head joint on the wall with screws provided. Slide the back of the sensor into the ball-head joint. The mounting angle can be adjusted.
There are 3 ways to control these modules / receivers:

Testing Walk test should be performed after the motion sensor is mounted. Walk in the detected area, if motion is detected, a red light inside the sensor will glow. If the red light does not glow, motion has not been detected and you may need to re-position the sensor. Ensure you walk test all the locations that you would like the motion sensor to cover.
Note: - Perform the walk test after you have inserted the battery for more than 1 minute. - Before performing the walk test, the sensor should not detect any motion. - After motion is detected once, the sensor will not be triggered unless no motion is detected for 20 seconds. Therefore, wait for at least 20 seconds during walk testing between 2 activations.
These control modules should be programmed to the control panel as device 1 to 5. Please follow the programming instructions below to program these control modules.
SENSOR
0 1 2 3 4 5 6 7 8 9 10 11 12 13
Both control panel and control module are transceivers, meaning they can transmit and receive signals from each other. For home automation, the user will initiate an action from the control panel, such as sending a signal to turn on the light, then the control module will receive such signal and respond. The control module will then send back a confirmation to the control panel to indicate the light has been turned on.

You have now successfully installed and programmed the Control Panel and its sensors. Please follow the rest of the instructions for operations and advanced programming.
Therefore, during programming, it is required to program 2 things:

The Control Panel is always in one of the 2 operating modes:

The Control Panel will be in alert mode automatically if the system is not armed. Alert mode allows users inside the premises to know what sensor is triggered. It is intended to be used when someone stays inside the premises.
In alert mode, the control panel will give you notification of the triggered sensor(s) by voice announcement, unique beeping and LED flashing.
1 Number of beeps Zone of the triggered sensor 2 Number of flashes of zone LED Sensor number of the triggered sensor
Proceed to the following to erase a sensor.

Alert Mode Examples (Door/Window sensor sold separately)

After [9] is entered, some zone LEDs will flash or stay off. The zone LEDs represent whether that zone is occupied by any sensor. **See Table D below.
To erase an occupied sensor, press [1] to [0].
Refer to the table below to select the remote location.
After you have selected the sensor, you will hear 3 beeps and verbal confirmation [Zone X Sensor Y Empty Memory], where X and Y are the zone and sensor numbers you have selected.
Flashes once This zone is occupied by sensor 1.
Flashes twice This zone is occupied by sensor 2.
-For motion sensor, the alert notification was disabled at the factory default. To perform the walk test, it requires to enable the Alert Zone (Bypass Zone) feature in the Control Panel. After the walk test, it needs to disable this alert zone feature otherwise it will bypass the signal in the alarm mode. Please refer to the page 33, "Alert Zone" for detail. Please refer to information.
Flashes once, This zone is occupied by sensors 1 and 2. then twice
** Table D: Zone LED status for erasing sensors.


zone 1 Beep / Alarm Y / N Disabled / On / Off Y / N zone 2 Beep / Alarm Y / N Disabled / On / Off Y / N zone 3 Beep / Alarm Y / N Disabled / On / Off Y / N zone 4 Beep / Alarm Y / N Disabled / On / Off Y / N zone 5 Beep / Alarm Y / N Disabled / On / Off Y / N
When the alert beeping becomes undesired, you can terminate the beeping in 3 different ways:
Pressing the mute button will temporary disable the beeping for all the activated sensors. For example, if a window with a window sensor will be open for a long period of time, the continuous beeping may become undesired. Pressing the mute button will temporary disable the beeping for this sensor only, it will still beep if other sensors are triggered. This sensor will beep again if this window is closed, and then opened.

Beep / Alarm Auto Mute Event Trigger Alert zone 1 Beep / Alarm Y / N Disabled / On / Off Y / N zone 2 Beep / Alarm Y / N Disabled / On / Off Y / N zone 3 Beep / Alarm Y / N Disabled / On / Off Y / N zone 4 Beep / Alarm Y / N Disabled / On / Off Y / N zone 5 Beep / Alarm Y / N Disabled / On / Off Y / N
You may refer to each column representing the zone dependent feature, to program each zone with the selected feature. For example, Auto Mute feature is only enabled for zone 3, when you are in the auto mute programming, you should enable this feature for zone 3 only, the rest of the zones should have this feature disabled. Repeat this step for all 4 zone dependent features during programming.
The beeping can be disabled for all zones by changing the buzzer mode selector.
- If the buzzer mode selector is at "I", beeping is enabled. - If the buzzer mode selector is at "II IIII II II", beeping is disabled.
[3] Select learn sensor programming
After [3] is entered, some zone LEDs will flash once, or twice, some will be off. The zone LEDs represent whether that zone is already occupied by another sensor. **See Table D next page.
If beeping is disabled, all sensor alert beeping will be disabled, however, the voice announcement and LED flashing will still function.
If this feature is enabled for that zone, beeping will be terminated automatically after 15 seconds . Refer to "Advanced Programming" - Auto Mute" on page 32 for more information on how to enable this feature.
[0] to [9] After you have selected the zone, that zone LED will be on.
Refer to the diagram below to select the sensor location, which includes the zone and sensor number.
Activate the sensor you would like to program to this zone.
Once the sensor is activated, the signal will be transmitted to the Control Panel which will be stored.
You will hear [Zone X Sensor Y Accepted], where X and Y are the zone and sensor numbers you have selected.

System Status
The control panel continuously monitors the system status as well as all the sensors status. It will monitor occurrences such as triggered sensors, low battery sensors, malfunction sensors, or phone line failure etc.
You can program up to 10 sensors to the control panel. There are 5 zones on the control panel, each zone can program up to 2 sensors. Before program- ming a sensor, you must decide which sensor location (zone number and sensor number) you would like to program the sensor to. It is strongly recom- mended that you refer to “Sensor Location Selection Guide” before deciding which sensor location you would like to program the new sensors to. Some features you may need to consider are: 1) Beep/Alarm setting, 2) auto mute, 3) alert zone , 4) event trigger. Explanation for each feature can be found in the following pages in Advanced Programming:
In order to check the system status, user can press the “Status” button on the control panel, voice announcement will be made regarding the system and sensor status. When the “Status” button is pressed, you will be notified if any of the following events is occurring:
- System armed or disarmed - Any triggered sensors - Any sensors with low battery warning - Any sensors with failure warning - Phone line failure
Refer to page 23 for more details regarding system failures.
Arming the System
You can program up to 10 sensors to the control panel. There are 5 zones and maximum 2 sesnors per zone. The 4 features mentioned above are Zone dependent features meaning both sensors in that zone will operate based on the setting for that zone. So if you program 2 sensors into one zone, those 2 sensors will react in the same manner for those zone dependent features. For example, if you enable the Auto-Mute feature for zone 1, both zone 1 sensor 1, and zone 1 sensor 2 will have this feature enabled. It is not possible to enable a zone dependent feature for sensor 1 only, but not sensor 2. Therefore, the followings are some suggestions of how you should select the sensor location.
You should arm the system when you are the last person to leave the house. By arming the system, the control panel will call the preprogrammed emergency phone numbers and the siren will sound when break-in occurs.
To arm the system, follow the procedures below:


Remote [6] is represented by zone LED 1

all sensors are in closed position, i.e. (close all doors, windows, no movement should be detected etc). - The control panel can be armed if there are sensors with low battery or failure
Follow the instructions below to erase keychain or keypad remotes / receivers.
[0] Select erase remote programming
After [0] is entered, some zone LEDs will flash or stay off. The zone LEDs represent whether that zone is occupied by any remote. ** See Table B below.
If a sensor is triggered while the control panel is armed, such as entering a house with an armed control panel, an entry delay will be triggered. User is allowed to disarm the control panel during the 30-second entry delay. If the control panel is not disarmed within 30 seconds, siren will sound immediately and emergency calls will be made. To disarm the control panel, follow the instructions below.
To erase an occupied remote, press [6] to [0].
Select remote location you would like to erase
Select a remote location [6], [7], [8], [9] or [0].
After you have selected the remote location, you will hear 3 beeps and verbal confirmation [Device X Empty Memory], where X is the remote location you have selected.

Off Zone is not occupied by any remote
Flashes twice This zone is occupied by a remote. You may select this zone to erase this remote.
Flashes once This zone is occupied by a control module (Optional). THIS IS NOT A REMOTE CONTROL, THEREFORE, SHOULD NOT BE ERASED. (Refer to page 43 Erase Control Module for more information)
2.Enter password within 30 seconds or press the disarm button on the keychain remote.
Flashes once, This zone is occupied by a remote AND a control module. then twice You may select this zone to erase the remote.
** Table B: Zone LED status for erasing keychain/keypad remote(s). * Please refer to erase control module on page 43.
Enter Programming mode

Additional keychain or keypad remotes can be programmed to the control panel. Maximum of 5 keychain/keypad remotes can be programmed to the control panel.
- Keychain or keypad remotes should be programmed to Device 6 to Device 0.
Follow the instructions below to program remote(s) to remote location(s) 6, 7, 8, 9, or 0, which is the bottom row of the numeric keypad of the control panel.
touch tone phone. Please refer to “Remote Operation by Telephone” on page 27.
- If 3 consecutive incorrect passwords are entered, alarm will sound immediately,
the control panel will be in panic mode, and start calling the emergency phone numbers.
[4] Select learn remote programming
After [4] is entered, some zone LEDs will flash or stay off. The zone LEDs represent whether that zone is already occupied by another remote. ** See Table A below.
If "System Panic" is announced from the control panel after it has been disarmed, that means the alarm was triggered when it was in armed mode. Follow the procedures below to set the control panel back to standby mode.
1. If the alarm was caused by sensor(s), there will be flashing LEDs and beeping indicating which sensor(s) triggered the alarm. You may want to check the condition of the triggered sensor(s), the sensor(s) may be damaged if there were break-ins. 2. You need to reset the sensor manually by triggering it twice, i.e. open and then close a door / window sensor, or walk in front of the motion sensor. The LED representing that sensor will stop flashing after it receives the signal from the sensor. 3. You must now enter the password again on the control panel or press the disarm button on the keychain remote, as an acknowledgement of the alarm event. This will set the control panel back to standby mode.
[6] to [0] Select remote location (Max. 5 remotes)
Select a remote location [6], [7], [8], [9] or [0].
After you have selected the remote location, that zone LED will be on.
Activate the remote by pressing any one of the buttons.
Trigger remote Once the signal is transmitted to the Control Panel, that signal which will be stored.
You will hear [Device X Accepted], where “X” is the remote location.
Off Zone is not occupied by any remote
Flashes twice This zone is occupied by another remote. Programming another remote to this zone will overwrite the previous remote.
Flashes once This zone is occupied by a control module* (Optional). You can still program a remote to this zone, and it will not overwrite the control module* you have in this zone. (Refer to page 40 Home Automation for more information)
If you are forcibly compelled to disarm the control panel, you may enter the Duress Password. Entering the duress password will terminate the entry delay, i.e. no more entry delay beeping. But the control panel will silently call the emergency phone numbers for help. The called party will hear the voice announcement “System Panic”.
Flashes once, This zone is occupied by a remote AND a control module*. then twice If you program another remote to this zone, it will overwrite the previous remote, but not the control module*.
** Table A: Zone LED status for learning keychain/keypad remote(s). * Please refer to learn control module on page 40.
Enter Program- ming mode

To enable alert zone feature, follow the instructions below.

Pressing the panic button on the control panel or keychain remote will cause the siren to sound and outgoing calls will be made to the preprogrammed phone numbers, “System Panic” will also be announced. This can be used in any emergency situation.
After [8] is entered, some zone LEDs will flash or stay on. This indicates whether alert zone is selected.
To stop the siren and disarm the system, user can enter a valid password, or press the disarm button on the keychain remote. This will terminate the siren and the control panel from calling the rest of the emergency phone numbers.
Select which zone you would like to select as Alert Zone.
Refer to the diagram below to select the appropriate setting.
If alert zone is selected, that zone LED will be on. If it is not selected, the LED will flash. You are allow to make multiple changes before terminat- ing programming mode.

- Control other Skylink receiver such as Garage Door Receiver

Control Panel constantly monitors itself and its sensors. If there are any trouble conditions, the control panel will advise the user. These trouble conditions include:
- Phone Line Failure - Sensor Failure (loss of supervisory signal) - Low Battery – Control Panel - Low Battery – Sensors
When the phone line is disconnected or malfunctions, the control panel will instantly notify the user by:
When phone line failure occurs, please check the phone line connection, ensure the phone line is plugged into both the control panel and the wall socket securely. You should also check the phone line with a normal telephone to determine if it can dial out to a phone number. If it cannot dial out, that indicates the phone line is not in service, you should contact your local phone company.

The control panel constantly monitors its sensors, if the control panel fails to communicate with any sensors, it will notify the user by:
ENABLE AUTO MUTE
When sensor failure occurs, try the following:
As explained earlier, the control panel can operate in 2 different modes, 1) Alert Mode, 2) Alarm Mode. In alarm mode, when a sensor is triggered, the control panel will either give a 30 seconds entry delay, or siren will sound immediately (with instant alarm). However, there are sensors that you do not want to trigger the alarm when the system is armed. Such as an outdoor sensor, or any other sensors that you only want to give you alert notification. Under such circum- stances, zone(s) can be programed to react only when the control panel is in alert mode, these zones will be automatically bypassed when the control panel is in alarm mode. These zones can also be considered as "Bypass zones".
Control Panel
The control panel is powered mainly by the adapter. However, during power outage, it will be powered by the rechargeable backup battery. Under standby conditions, these batteries can last for 48 hours.
When the backup battery is running low, the “LO BATT” LED on the control panel will be on, indicating the backup battery should be recharged. To recharge the backup battery, plug in the power adapter. It takes approx. 20 hours to fully charge the backup battery.
- You do not consider the sensors in that zone an emergency - Sensors in that zone are located outdoors - When nobody is at home, you do not want to know the status of the sensor(s) in
Sensors (For ML-100A Only)
Factory Default: This feature was disabled for all zones at the factory.
All of the sensors are battery powered. Depending on the operating condition and environment, the battery life varies from 9 months to 2 years. 9V alkaline battery is used for the motion sensor, the battery life is approximately 9 months. Door / Window Sensor operates on a Lithium CR-2032 battery, with battery life of approximately 2 years. For other sensors, please refer to the user’s instructions regarding the battery life.

When the sensor is running low in battery, the sensor will send a wireless low battery signal to the control panel. The zone LED representing that sensor will be on steadily, indicating sensor(s) in that zone is in trouble condition. Control Panel will also have an announcement to advise the user the trouble condition is low battery, such as “zone X sensor Y low battery”, where X and Y represent the zone and sensor number. Please replace the battery of that sensor.
When a sensor is triggered in alert mode, audio warning will be emitted, either beep or alarm. For example, if a door is opened, the beep will not stop until the door is closed. If the door is open for 2 hours, the beep will go on for 2 hours. There are times that this is not desired. With the auto mute feature enabled, the beep will go on for only 20 seconds. After that, even if the sensor remains open, the beep will stop only the zone LED will flash to indicate the sensor is triggered. Beep will go on again if the sensor is closed and opened again.
Keychain Remote (For ML-100A Only)
The battery of the keychain remote (Alkaline, Type 23A, 12V) needs to be replaced when either one of the followings occurs:
Factory Default: This feature was disabled for all zones at the factory.
To replace the battery:
To enable auto mute feature, follow the instructions below.
[6] Select Auto Mute Enable / Disable
After [6] is entered, some zone LEDs will flash or stay on. This indicates whether Auto Mute is enabled or disabled.
Select which zone you would like to enable / disable auto mute.
Refer to the diagram below to select the appropriate setting.
If auto mute is enabled, that zone LED will be on. If it is disabled, the LED will flash. You are allow to make multiple changes before terminating programming mode.
Enable Auto Mute: [6] to [0].
Terminate programming mode.
PROG LED will be off, and you will hear 3 beeps.
[PROG] when finished.
Enter Program- ming mode

Follow the procedures below to program the beep / alarm setting.
If you are on the list as one of the recipients of the emergency call, you should read the following instructions carefully. You should also notify all the persons you will be calling so they know how to react when they receive the emergency call.

The control panel will call you when there are emergencies such as break-ins, smoke, fire events, or someone at home needs assistance.
After [5] is entered, some zone LEDs will flash or stay on. This indicates whether that zone is set to beep or alarm.
Refer to the diagram below to select the appro- priate setting.
Select which zone you would like to Beep or Alarm.
If Alarm is set for that zone, that zone LED will be on. If Beep is set, the LED will flash. You are allowed to make multiple changes before terminating programming mode.
PROG LED will be off, and you will hear 3 beeps.

Zone 1 Sensor 1 Triggered
-Arm -Disarm -Check status -Control lighting etc. -Disconnect
Example: If you would like to change the setting for zone 5 from “Beep” to “Alarm”, simply press [0] at step 3. This will change the zone 5 setting to “Alarm”.
Enter Password

If a zone is set to “Beep”, the control panel will give entry / exit delay. If a zone is set to “Alarm”, the siren will sound immediately without entry delay
The control panel can be operated while you are away from home. You can have access to the control panel with any touch tone phone to perform a variety of operations, listed below.
- Alarm Mode (System Armed): If a sensor is triggered (i.e. opening a door) with the alarm setting on, the siren will sound immediately without entry delay, it is called “Instant Alarm”. The siren will not stop until the siren timeout or a valid password is entered. Control panel will call the emergency phone numbers to notify the users of the alarm situation.
- Arm - Disarm - Lights, Home Applicances on / off (Requires additonal Control Module) - Garage door open / close (Requires additional Garage Door Receiver) - System status - Disconnect
When a sensor is triggered, there are 4 options:
There are 2 ways you can have access to the remote phone operation:
Disarmed (Alert) 1) Beep 2) Alarm sounds immediately
Armed (Alarm) 3) Entry / Exit Delay 4) Alarm sounds and calls preprogrammed phone numbers immediately
Factory Default: All zones were programmed to Beep at the factory.
- You need immediate attention if that sensor is triggered, such as flood sensor,
smoke sensor etc. - The sensor will not be triggered on a daily basis, such as a door that you
normally will not open, and if it opens, you would like to know immediately.

Advanced Programming allows users to customize the control panel to react differently under different conditions. Features such as:
SYSTEM OPERATION PHONE COMMAND DESCRIPTION
- When a sensor is triggered, the control panel can beep or alarm - Beeping can be terminated automatically after a fixed period of time for some sensors - Some sensors can be programmed to beep only, never alarm - When a door is open, turn lights on - Program additional sensors and remotes
Turn on device x [x] = 1 to 5
Turn devices on will hear [Device X On]. When the control module receives the on signal, it will turn on the plugged in device, and send a confirmation back to the control panel. You will then hear [Device On Accepted].
Turn off device x x = [1 to 5]
Turn devices off will hear [Device X Off]. When the control module receives the off signal, it will turn off the plugged in device, and send a confirmation back to the control panel. You will then hear [Device Off Accepted].
You will hear system status announcement
[PROG] + [1] Program Phone Numbers
You will hear [System Armed]
[PROG] + [2] Program Password
[PROG] + [3] Learn Sensors
You will hear [System Disarmed]
[PROG] + [4] Learn Keychain or Keypad Transmitters / Control Modules
[PROG] + [5] Beep / Alarm Setting
[PROG] + [6] Auto Mute Setting
[PROG] + [7] Event Trigger Setting
[PROG] + [8] Alert Zone (Bypass) Setting
[PROG] + [9] Erase Sensors
[PROG] + [0] Erase Keychain or Keypad Transmitters / Control Modules
Follow the instructions below to have access to Advanced Programming.
User can customize the audio warning so that when a sensor is triggered, the control panel may beep or alarm may sound instantly. Depending on whether the control panel is armed or disarmed, the audio warning is different.
If a zone is set to “Beep”, the control panel will beep when a sensor is triggered, until the sensor is deactivated. Motion Sensor activation will not cause any beeping unless the zone for the motion sensor is programmed as a "Bypass Zone" (see page 33).
If a zone is set to “Alarm”, alarm will sound instantly when a sensor is triggered. Alarm will stop when the sensor is deactivated, or reaches a 3-minute time out period.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.