Air-Conditioners SLZ-A09, A12, A18AR

OPERATION MANUAL For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.

FOR USER

English

BEDIENUNGSHANDBUCH Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen. MANUEL D’UTILISATION Pour une utilisation correcte sans risques, veuillez lire le manuel d’utilisation en entier avant de vous servir du climatiseur.

FÜR BENUTZER

Deutsch

POUR L’UTILISATEUR

Français

BEDIENINGSHANDLEIDING Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de airconditioner gebruikt.

VOOR DE GEBRUIKER

Nederlands

MANUAL DE INSTRUCCIONES Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado para garantizar un uso seguro y correcto.

PARA EL USUARIO

Español

ISTRUZIONI DI FUNZIONAMENTO Leggere attentamente questi istruzioni di funzionamento prima di avviare l’unità, per un uso corretto e sicuro della stessa.

PER L’UTENTE

Italiano

E°XEIPI¢IO O¢H°IøN XPH™Eø™ °È· ·ÛÊ¿ÏÂÈ· Î·È ÛˆÛÙ‹ ¯Ú‹ÛË, ·Ú·Î·Ï›ÛÙ ‰È·‚¿ÛÂÙ ÚÔÛ¯ÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ¯Ú‹Ûˆ˜ ÚÈÓ ı¤ÛÂÙ Û ÏÂÈÙÔ˘ÚÁ›· ÙË ÌÔÓ¿‰· ÎÏÈÌ·ÙÈÛÌÔ‡.

∂ÏÏËÓÈο

MANUAL DE OPERAÇÃO Para segurança e utilização correctas, leia atentamente o manual de operação antes de pôr a funcionar a unidade de ar condicionado.

PARA O UTILIZADOR

Português

DRIFTSMANUAL Läs denna driftsmanual noga för säkert och korrekt bruk innan luftkonditioneringen används.

FÖR ANVÄNDAREN

Svenska

°π∞ ∆√¡ Ã∏™∆∏

Page 3 of the Mitsubishi Electronics A12 user manual — SLZ-A09/A12/A18AR
Page 3 · click to enlarge
Page 3

2. Operation

  • 2.1. Description of “AUTO RESTART FUNCTION”
  • This unit is equipped with the auto restart function. When the main power is turned on, the air conditioner will start operation automatically in the same mode as set with the remote controller before the shutoff of main power.
  • If the unit was set to off with the remote controller before the shutoff of main power, it will remain stopped even after the main power is turned on.
  • If the unit was in the TEST RUN before the shutoff of main power, it will start operation, at main power on, in the same mode as set with the remote controller before the TEST RUN.

DRY HEAT

AUTO COOL

VANE

FAN

  • 2.2. Remote controller (How to set the batteries) 1 Remove the back lid and insert batteries. Then reattach the back lid.
  • Insert the minus pole of the batteries first.
  • Check if the polarity of the batteries is correct. 2 Press the RESET button.
  • If the RESET button is not pressed, the remote controller may not operate correctly.
  • Press using a thin stick.

SELECT

TIME

Mitsubishi Electronics A12 — SELECT diagram (page 3)
Fig. 1
  • 2.3. Switching the unit on/off
  • The power supply should not be turned off while the air conditioner is in use. This can cause the unit to break down. 1 Press the ON/OFF button.
  • Even if you press the ON/OFF button immediately after shutting down the operation in progress, the air conditioner will not start for about three minutes. This is to prevent the internal components from being damaged. A For the after-mentioned operating functions of the remote controller,

A

all items are indicated in this illustration.

2.4. Mode select 1If the unit is off, press the ON/OFF button to turn it on. 2Press the operation mode MODE button and select the operation mode. Each time the operation mode

A

MODE button is pressed the moves. (A)

SLZ-A09/A12/A18AR

Information for multi system air conditioner (Outdoor unit: MXZ series) sMulti system air conditioner (Outdoor unit: MXZ series) can con-

  • nect two or more indoor units with one outdoor unit. According to the capacity, two or more units can operate simultaneously.
  • When you try to operate two or more indoor units with one outdoor unit simultaneously, one for the cooling and the other for heating, the operation mode of the indoor unit that operates earlier is selected. The other indoor units that will start the operation later cannot operate, indicating an operation state. In this case, please set all the indoor units to the same operation mode.
  • There might be a case that the indoor unit, which is operating in (AUTO) mode. Cannot change over to the operating mode (COOL ↔ HEAT) and becomes a state of standby.
  • When indoor unit starts the operation while the defrosting of outdoor unit is being done, it takes a few minutes (max. about 15 minutes) to blow out the warm air.
  • In the heating operation, though indoor unit that does not operate may get warm or the sound of refrigerant flowing may be heard, they are not malfunction. The reason is that the refrigerant continuously flows into it.
Show 5 more labels / short text on this page
s · Automatic (cooling/heating) mode · Cooling mode · Drying mode · Heating mode
Page 4 of the Mitsubishi Electronics A12 user manual — RESET
Page 4 · click to enlarge
Page 4

2. Operation

2.5. Selecting a temperature s To decrease the room temperature: 1 Press

TOO WARM button to set the desired temperature. A The selected temperature is displayed. • Each time you press the button, the temperature value decreases by 1 °C.

A

ON/OFF

TOO WARM

TOO COOL

sTo increase the room temperature: 1Press

TOO COOL button to set the desired temperature. A The selected temperature is displayed. • Each time you press the button, the temperature value increases by 1 °C.

AUTO COOL

FAN

SELECT

DRY HEAT

VANE

TIME

MODE

  • Available temperature ranges are as follows: Cooling/Drying: 19 - 30 °C Heating: 17 - 28 °C Automatic: 19 - 28 °C

RESET

2.6. Selecting a fan speed 1 Press

FAN button to select a desired fan speed. • Each time you press the button, available options change with the dis- play A on the remote controller, as shown below.

A

Fan speedRemote controller display LowMediumHigh 3-stageMMM

ON/OFF

TOO WARM

TOO COOL

FAN

SELECT

AUTO COOL

VANE

TIME

DRY HEAT

  • In the following situations, the display differs from the fan speed of the unit.
  • In the case of DEFROST/STAND BY lamp lighting of the unit.
  • Just after the heating mode (while waiting to change to another mode).
  • When the temperature of the room is higher than the temperature setting of the unit operating in the heating mode.
  • In drying mode, the indoor fan sometimes stops.

MODE

RESET

2.7. Adjusting vertical airflow direction The vertical air vane helps select the vertical direction of the airflow. 1Press VANE button to select the vertical airflow direction. A Each time you press the button, the option changes are displayed on

A

the remote controller, as shown below.

ON/OFF

TOO WARM

TOO COOL

1 → 2 → 3 → 4 → 5

FAN

SELECT

AUTO COOL

  • 1 Horizontal airfrow 30° 4 Downword airfrow 70° 2 Downword airfrow 45° 5 Swing 3 Downword airfrow 55°
  • In either cooling or drying mode, if you select 2 or 3 or 4 when the fan speed is Low or Medium, the airconditioner will switch automatically to Horizontal airflow 1 mode after one hour. In the following situations, the display differs from the vertical airflow direction of the unit.
  • In the case of DEFROST/STAND BY lamp lighting of the unit.
  • When the temperature of the room is higher than the temperature setting of the unit operating in the heating mode.

TIME 1

DRY HEAT

VANE

MODE

RESET

2.8. Using the timer It is convenient to set the timer when you go to bed, when you get home, when you get up, etc. 1Select the timer mode by pressing the

SELECT button during operation. A Each time this button is pressed, the timer mode is changed in se-

B A

ON/OFF

TOO WARM

TOO COOL

quence:

(OFF TIMER) (ON TIMER) TIMER RELEASE

FAN

SELECT

AUTO COOL

2Set the time of the timer using the TIME button. B Each time this button is pressed, the set time increases by 1 hour to

DRY HEAT

VANE

TIME

12 hours.

MODE

To release the timer• Press the

RESET

SELECT button until (OFF TIMER) and (ON TIMER) are not displayed.

Show 6 more labels / short text on this page
For SLZ-A09/A12/A18AR · For SLZ-A09/A12/A18AR · s · For SLZ-A09/A12/A18AR · h · For SLZ-A09/A12/A18AR
Page 5 of the Mitsubishi Electronics A12 user manual — B A
Page 5 · click to enlarge
Page 5

2. Operation

2.9. Emergency operation When the remote controller cannot be used When the batteries of the remote controller run out or the remote controller malfunctions, the emergency operation can be done using the emergency buttons on the grille.

  • A DEFROST/STAND BY lamp B Operation lamp C Emergency operation switch (heating) D Emergency operation switch (cooling) E Receiver Starting operation
  • To operate the cooling mode, press the button D .
  • To operate the heating mode, press the button C . Note:
  • Details of emergency mode are as shown below. Details of EMERGENCY MODE are as shown below. However, the temperature control does not work for 30 minutes in test run and the unit is set to continuous operation. The fan speed is set to High in test run and shifts to Medium after 30 minutes.

A B C D E

Operation modeCOOLHEAT Set temperature Fan speed24°C med.24°C med. Airflow directionHorizontal 30°Downward 70°
Mitsubishi Electronics A12 — A B C D E diagram (page 5)
Fig. 2

3. Care and cleaning

  • Caution:
  • Always turn off the power, first on the remote controller and then the main switch, before cleaning or servicing the unit.
  • When installing or removing the filter or the intake grille, do not stand on an unsteady surface. You may fall and injure yourself. Be also careful not to let dust fall into your eyes. Dirty or clogged filters block the airflow and reduce efficiency. Very dirty filters can damage the air-conditioner itself. Intake grille removal 1 Pull the catch on the intake grille in the direction indicated by the arrow and it should open. 2 Unhook the hinges to remove the intake grille from the grille. Filter removal 1 Open the intake grille. 2 Release the catch on the center edge of the intake grille and pull the filter forward to remove the filter.

B A

D

A Catch B Grille C Intake grille D Filter

Mitsubishi Electronics A12 — B A diagram (page 5)
Fig. 3
  • 3.1. Cleaning the filters and the indoor unit Cleaning the filter
  • Clean the filter using a vacuum cleaner. If you do not have a vacuum cleaner, tap the filter against a solid object to knock off dirt and dust.
  • If the filter is especially dirty, wash it in lukewarm water. Take care to rinse off any detergent thoroughly and allow the filter to dry completely before putting it back into the unit.
  • Caution:
  • Do not dry the filter in direct sunlight or by using a heat source, such as an electric heater: this may warp it.
  • Do not wash the filter in hot water (above 50°C), as this may warp them.
  • Make sure that the air filter is always installed. Operating the unit without air filter can cause malfunction.
Mitsubishi Electronics A12 — B A diagram (page 5)
Fig. 4
  • Cleaning the indoor unit
  • Wipe the outside of the unit with a clean, dry, soft cloth.
  • Clean off any oil stains or finger marks using a neutral household detergent (such as dishwashing liquid or laundry detergent).
Page 6 of the Mitsubishi Electronics A12 user manual — TV
Page 6 · click to enlarge
Page 6

4. Troubleshooting

Before you call out a repair man, check the following table to see whether there is a simple solution to your problem.

ProblemSolutionProblemSolution Unit does not cool or heat very well.Clean the filter.The operation lamp of the wireless remote controller’s receiver is flashing.A self-diagnostic function is being performed to preserve the air conditioner. * Do not attempt to make repairs yourself. Turn the main switch off and contact the dealer from whom you bought the air conditioner. Provide him or her with the name of the unit and the number of times the operation lamp of the wireless remote controller’s receiver flashes. The airflow direction suddenly changes.After one hour of cooling mode or drying mode operation with the airflow in a downward direction, the unit will automatically change to the “Horizontal airflow” mode. When the unit is in the heating or defrosting mode, it will automatically change to the “Horizontal airflow” mode. A white mist is expelled from the indoor unit.This may occur just after the unit is turned on when a high level of humidity is present in the room. Unit operates even if ON/OFF button has not been pressed.It occurs for the AUTO RESTART FUNCTION mode. Press the ON/OFF button to stop operation. The air conditioner cannot be operated for about 3 minutes when restarted.This protects the air conditioner according to instructions from the microprocessor. Please wait. No indication of wireless remote controller, indication is dim, or signal transmission cannot reach remote controller sensor.The batteries have run out. Replace the batteries with new ones (size AAA), and then press the reset button. Though both alkaline batteries and manganese batteries can be used, alkaline batteries are recommended because their service life is longer than that of manganese batteries. * If indication is not detected even when new batteries have been replaced, check that the batteries have been installed properly. Air does not blow out soon in the heating operation.Please wait as the air conditioner is preparing to blow out warm air. The start and stop functions are not available just after restarting the unit.Wait about three minutes (operation has stopped to prevent damage to the air conditioner). The operation is stopped for about 10 minutes in the heating operation.Defrosting of the outdoor unit is being done (Defrosting operation). Since this is completed in 10 minutes, please wait. (When the external temperature is too low and humidity is too high, frost is formed.)

If none of the above apply, turn the main switch off and contact the dealer from whom you bought the air-conditioner, telling him the model name and the nature of the problem. Do not try to fix the unit yourself.

  • In any of the following cases, turn off the main power switch and contact your local dealer for service:
  • The operation lamp (on the main unit) flashes.
  • The switches do not work properly.
  • The circuit breaker trips frequently (or the fuse blows frequently).
  • Water has accidentally been splashed into the unit.
  • Water leaks from the unit.
  • Something is accidentally dropped into the air-conditioner.
  • An unusual noise is heard during operation.

The following do not indicate any malfunction: Odours: smells such as tobacco or cosmetic odours may persist after they have been sucked into the unit. Sound of liquid flowing inside indoor unit: this can occur during or after operation and is simply the sound of refrigerant being circulated inside the unit. Ticking sound coming from indoor unit: this can occur when cooling or heating has just begun or has just stopped. It is caused by the indoor unit shrinking or expanding slightly due to the change in temperature.

5. Installation, relocation and inspection

Installation place Avoid installing the air conditioner in the following places. • Where flammable gas could leak.

Inverter type fluorescent lamp

Wall, etc.

To prevent the effect of a fluorescent lamp, keep it away as far apart as possible.

  • Where there is much machine oil.
  • Salty place such as the seaside.
  • Where sulfide gas is generated such as a hot spring.
  • Where there is oil splashing or much oily smoke.

To prevent picture distortion or noise, keep 1 m or more apart.

100 mm or more

400 mm or more

TV

Warning: If the air conditioner operates but does not cool or heat (depending on model) the room, consult your dealer since there may be a refrig- erant leak. Be sure to ask the service representative whether there is refrigerant leakage or not when repairs are carried out. The refrigerant charged in the air conditioner is safe. Refrigerant nor- mally does not leak, however, if refrigerant gas leaks indoors, and comes into contact with the fire of a fan heater, space heater, stove, etc., harmful substances will be generated.

Well- ventilated dry place · Radio

Page 7 of the Mitsubishi Electronics A12 user manual — 6. Specifications
Page 7 · click to enlarge
Page 7

5. Installation, relocation and inspection

  • Electrical work
  • Provide an exclusive circuit for power supply of the air conditioner.
  • Be sure to observe the breaker capacity.
  • Warning:
  • The customer should not install this unit. If the unit is installed incorrectly, fire, electric shock, injury due to a falling unit, water leakage, etc. may result.
  • Do not connect using branched outlet or an extension cord, and do not attach many loads to one electric outlet. A fire or electric shock may result from poor contact, poor insulation, exceeding the permissible current, etc. Consult your dealer.
  • Caution:
  • Apply grounding Do not connect a grounding wire to a gas pipe, water pipe, lightning rod or ground wire of a telephone. If a grounding is incorrect, it may cause an electric shock.
  • Install an earth leakage breaker depending on the place where the air conditioner is to be installed (humid place, etc.). If the earth leakage breaker is not installed, it may cause an electric shock.
  • Inspection and maintenance
  • When the air conditioner is used for several seasons, the capacity may be lowered due to dirt inside the unit.
  • Depending upon the conditions of use, an odor may be generated or dirt, dust, etc. may prevent proper drainage.
  • It is recommended to apply inspection and maintenance (charged) by a specialist in addition to normal maintenance. Consult your dealer.
  • Also consider operation sound
  • Do not put an object around the air outlet of the outdoor unit. It may cause lowering of capacity or increase operating sound.
  • If abnormal sound is heard during operation, consult your dealer.

Relocation • When the air conditioner is to be removed or reinstalled because of rebuilding, moving, etc., special techniques and work are required.

Disposal • To dispose of this product, consult your dealer.

If you have any question, consult your dealer.

6. Specifications

ModelSLZ-A09ARSLZ-A12ARSLZ-A18AR FunctionCoolingHeatingCoolingHeatingCoolingHeating Power supply~/N, 220-240V, 50Hz CapacitykW2.53.03.23.84.34.8 BTU/h8,50010,20010,90012,90014,60016,300 InputkW0.760.871.061.071.531.50 Indoor unitSLZ-A09ARSLZ-A12ARSLZ-A18AR Airflow (Lo-Hi)CMM8-109-119-11 Noise level (Lo-Hi)dB32-3834-3935-40 Weightkg16.5 + Grille 316.5 + Grille 316.5 + Grille 3 Outdoor unitSUZ-A09VRSUZ-A12VRSUZ-A18VR Noise leveldB464855 Refrigerant R410Akg0.80.91.8 Weightkg333472 Notes: 1. Rating conditions (cooling) Indoor : 27°C DB, 19°C WB Outdoor : 35°C DB 2. Rating conditions (heating) Indoor : 20°C DB Outdoor : 7°C DB, 6°C WB 3. Specifications subject to change without notice. Guaranteed operating range Indoor Outdoor Upper limit 32°C DB, 23°C WB 46°C DB, – Cooling Lower limit 21°C DB, 15°C WB -10°C DB, – Upper limit 27°C DB 24°C DB, 18°C WB Heating Lower limit 20°C DB -10°C DB, -11°C WB IndoorOutdoor CoolingUpper limit32°C DB, 23°C WB46°C DB, – Lower limit21°C DB, 15°C WB-10°C DB, – HeatingUpper limit27°C DB24°C DB, 18°C WB Lower limit20°C DB-10°C DB, -11°C WB

Units should be installed by licensed electric contractor accordingly to local code requirement.

Page 8 of the Mitsubishi Electronics A12 user manual — The product at hand is based on the following EU regulations:
Page 8 · click to enlarge
Page 8

This product is designed and intended for use in the residential,

commercial and light-industrial environment.

  • Low Voltage Directive 73/23/ EEC
  • Electromagnetic Compatibility Directive 89/ 336/ EEC

The product at hand is based on the following EU regulations:

Please be sure to put the contact address/telephone number on

this manual before handing it to the customer.

HEAD OFFICEMITSUBISHI DENKI BLDG., 2-2-3, MARUNOUCHI, CHIYODA-KU, TOKYO 100-8310, JAPAN

Printed in Thailand BG79U162H01

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Unit does not cool or heat very well.Clean the filter. p.6
The airflow direction suddenly changes.After one hour of cooling mode or drying mode operation with the airflow in a downward direction, the unit will auto- matically change to the “Horizontal air- flow” mode. p.6
The airflow direction suddenly changes.When the unit is in the heating or defrost- ing mode, it will automatically change to the “Horizontal airflow” mode. p.6
A white mist is expelled from the indoor unit.This may occur just after the unit is turned on when a high level of humidity is present in the room. p.6
A white mist is expelled from the indoor unit. p.6
The air conditioner cannot be operated for about 3 minutes when restarted.This protects the air conditioner accord- ing to instructions from the microproces- sor. Please wait. p.6
The air conditioner cannot be operated for about 3 minutes when restarted. p.6
Air does not blow out soon in the heating operation.Please wait as the air conditioner is pre- paring to blow out warm air. p.6
The start and stop functions are not avail- able just after restarting the unit.Wait about three minutes (operation has stopped to prevent damage to the air con- ditioner). p.6
The operation is stopped for about 10 minutes in the heating operation.Defrosting of the outdoor unit is being done (Defrosting operation). Since this is completed in 10 minutes, please wait. (When the external tempera- ture is too low and humidity is too high, frost is formed.) p.6

Ask about the Mitsubishi Electronics A12

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Mitsubishi Electronics A12

Be the first to ask — other owners or our team will answer.

Original document

Mitsubishi Electronics A12 manual PDF

8 pages·477 KB·Air Conditioner·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…