OPERATION MANUAL For safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.
English
BEDIENUNGSHANDBUCH Zum sicheren und einwandfreien Gebrauch der Klimaanlage dieses Bedienungshandbuch vor Inbetriebnahme gründlich durchlesen. MANUEL D’UTILISATION Pour une utilisation correcte sans risques, veuillez lire le manuel d’utilisation en entier avant de vous servir du climatiseur.
Deutsch
POUR L’UTILISATEUR
Français
BEDIENINGSHANDLEIDING Voor een veilig en juist gebruik moet u deze bedieningshandleiding grondig doorlezen voordat u de airconditioner gebruikt.
Nederlands
MANUAL DE INSTRUCCIONES Lea este manual de instrucciones hasta el final antes de poner en marcha la unidad de aire acondicionado para garantizar un uso seguro y correcto.
Español
ISTRUZIONI DI FUNZIONAMENTO Leggere attentamente questi istruzioni di funzionamento prima di avviare l’unità, per un uso corretto e sicuro della stessa.
Italiano
E°XEIPI¢IO O¢H°IøN XPH™Eø™ °È· ·ÛÊ¿ÏÂÈ· Î·È ÛˆÛÙ‹ ¯Ú‹ÛË, ·Ú·Î·Ï›ÛÙ ‰È·‚¿ÛÂÙ ÚÔÛ¯ÙÈο ·˘Ùfi ÙÔ ÂÁ¯ÂÈÚ›‰ÈÔ ¯Ú‹Ûˆ˜ ÚÈÓ ı¤ÛÂÙ Û ÏÂÈÙÔ˘ÚÁ›· ÙË ÌÔÓ¿‰· ÎÏÈÌ·ÙÈÛÌÔ‡.
MANUAL DE OPERAÇÃO Para segurança e utilização correctas, leia atentamente o manual de operação antes de pôr a funcionar a unidade de ar condicionado.
Português
DRIFTSMANUAL Läs denna driftsmanual noga för säkert och korrekt bruk innan luftkonditioneringen används.
Svenska
°π∞ ∆√¡ Ã∏™∆∏


AUTO COOL
VANE
FAN
TIME

all items are indicated in this illustration.
2.4. Mode select 1If the unit is off, press the ON/OFF button to turn it on. 2Press the operation mode MODE button and select the operation mode. Each time the operation mode
MODE button is pressed the moves. (A)
Information for multi system air conditioner (Outdoor unit: MXZ series) sMulti system air conditioner (Outdoor unit: MXZ series) can con-

TOO WARM button to set the desired temperature. A The selected temperature is displayed. • Each time you press the button, the temperature value decreases by 1 °C.
ON/OFF
TOO WARM
TOO COOL
sTo increase the room temperature: 1Press
TOO COOL button to set the desired temperature. A The selected temperature is displayed. • Each time you press the button, the temperature value increases by 1 °C.
FAN
SELECT
DRY HEAT
VANE
TIME
MODE
2.6. Selecting a fan speed 1 Press
FAN button to select a desired fan speed. • Each time you press the button, available options change with the dis- play A on the remote controller, as shown below.
TOO WARM
TOO COOL
FAN
SELECT
AUTO COOL
VANE
TIME
DRY HEAT
RESET
2.7. Adjusting vertical airflow direction The vertical air vane helps select the vertical direction of the airflow. 1Press VANE button to select the vertical airflow direction. A Each time you press the button, the option changes are displayed on
the remote controller, as shown below.
TOO WARM
TOO COOL
1 → 2 → 3 → 4 → 5
SELECT
AUTO COOL
DRY HEAT
VANE
MODE
RESET
2.8. Using the timer It is convenient to set the timer when you go to bed, when you get home, when you get up, etc. 1Select the timer mode by pressing the
SELECT button during operation. A Each time this button is pressed, the timer mode is changed in se-
ON/OFF
TOO WARM
TOO COOL
quence:
FAN
SELECT
AUTO COOL
2Set the time of the timer using the TIME button. B Each time this button is pressed, the set time increases by 1 hour to
VANE
TIME
12 hours.
SELECT button until (OFF TIMER) and (ON TIMER) are not displayed.

2.9. Emergency operation When the remote controller cannot be used When the batteries of the remote controller run out or the remote controller malfunctions, the emergency operation can be done using the emergency buttons on the grille.

D
A Catch B Grille C Intake grille D Filter



Before you call out a repair man, check the following table to see whether there is a simple solution to your problem.
If none of the above apply, turn the main switch off and contact the dealer from whom you bought the air-conditioner, telling him the model name and the nature of the problem. Do not try to fix the unit yourself.
The following do not indicate any malfunction: Odours: smells such as tobacco or cosmetic odours may persist after they have been sucked into the unit. Sound of liquid flowing inside indoor unit: this can occur during or after operation and is simply the sound of refrigerant being circulated inside the unit. Ticking sound coming from indoor unit: this can occur when cooling or heating has just begun or has just stopped. It is caused by the indoor unit shrinking or expanding slightly due to the change in temperature.
Installation place Avoid installing the air conditioner in the following places. • Where flammable gas could leak.
Inverter type fluorescent lamp
Wall, etc.
To prevent the effect of a fluorescent lamp, keep it away as far apart as possible.
To prevent picture distortion or noise, keep 1 m or more apart.
100 mm or more
400 mm or more
Warning: If the air conditioner operates but does not cool or heat (depending on model) the room, consult your dealer since there may be a refrig- erant leak. Be sure to ask the service representative whether there is refrigerant leakage or not when repairs are carried out. The refrigerant charged in the air conditioner is safe. Refrigerant nor- mally does not leak, however, if refrigerant gas leaks indoors, and comes into contact with the fire of a fan heater, space heater, stove, etc., harmful substances will be generated.
Well- ventilated dry place · Radio

Relocation • When the air conditioner is to be removed or reinstalled because of rebuilding, moving, etc., special techniques and work are required.
Disposal • To dispose of this product, consult your dealer.
If you have any question, consult your dealer.
Units should be installed by licensed electric contractor accordingly to local code requirement.

commercial and light-industrial environment.
Please be sure to put the contact address/telephone number on
this manual before handing it to the customer.
Printed in Thailand BG79U162H01
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Unit does not cool or heat very well. | Clean the filter. | p.6 | |
| The airflow direction suddenly changes. | After one hour of cooling mode or drying mode operation with the airflow in a downward direction, the unit will auto- matically change to the “Horizontal air- flow” mode. | p.6 | |
| The airflow direction suddenly changes. | When the unit is in the heating or defrost- ing mode, it will automatically change to the “Horizontal airflow” mode. | p.6 | |
| A white mist is expelled from the indoor unit. | This may occur just after the unit is turned on when a high level of humidity is present in the room. | p.6 | |
| A white mist is expelled from the indoor unit. | p.6 | ||
| The air conditioner cannot be operated for about 3 minutes when restarted. | This protects the air conditioner accord- ing to instructions from the microproces- sor. Please wait. | p.6 | |
| The air conditioner cannot be operated for about 3 minutes when restarted. | p.6 | ||
| Air does not blow out soon in the heating operation. | Please wait as the air conditioner is pre- paring to blow out warm air. | p.6 | |
| The start and stop functions are not avail- able just after restarting the unit. | Wait about three minutes (operation has stopped to prevent damage to the air con- ditioner). | p.6 | |
| The operation is stopped for about 10 minutes in the heating operation. | Defrosting of the outdoor unit is being done (Defrosting operation). Since this is completed in 10 minutes, please wait. (When the external tempera- ture is too low and humidity is too high, frost is formed.) | p.6 |