Instruction/ maintenance manual of the product R380-SS METRObility Optical Systems
Go to page of 36
R ADIANCE M UL TI -R AT E L INE C ARD MULTIRATE LB BP PWR 1 2 SD LB BP SD RX TX RX TX Installation & User Guide Model: R380-SS.
Radiance Multi-Rate Line Card Line Card: R380-SS ______ Multi-rate SFP to SFP Small Form-Factor Pluggable (SFP) Multimode Optics: O21 1-M5 ______ 1 Gbps SFP LC (multimode, 500 m) O221-M5 ______ Multi-rate SFP LC (multimode, 1.
O413-40-47 ____ Multi-rate SFP LC (CWDM, 155 Mbps to 2.7 Gbps, 1470 nm, 40 km) O413-40-49 ____ Multi-rate SFP LC (CWDM, 155 Mbps to 2.7 Gbps, 1490 nm, 40 km) O413-40-51 ____ Multi-rate SFP LC (CWDM, 155 Mbps to 2.7 Gbps, 1510 nm, 40 km) O413-40-53 ____ Multi-rate SFP LC (CWDM, 155 Mbps to 2.
4 T able of Contents Radiance Multi-Rate Line Card Installation & User Guide Overview ............................................................................................................... 5 Installation Guide ............................
Radiance Multi-Rate Line Card 5 Overview The Radiance multi-rate line card with dual small form-factor pluggable (SFP) optics provides a simple and versatile solution for converting between two physical data formats. Use it to connect multimode to singlemode fiber , or singlemode fiber with different wavelengths.
6 The Radiance multi-rate line card includes the following key features: • Support for frequencies ranging from 44.7 Mbps up to 2.7 Gbps. • Auto-detection or manual frequency settings. • T emperature and optical power monitors. • A wide range of SFP transceiver options compliant with Multi-Source Agree- ment (MSA) specifications.
Radiance Multi-Rate Line Card 7 • Operates in any Metrobility chassis enclosure such as the Radiance R5000, R1000, R400, R200, or RD-20. • Manageable using Metrobility’ s NetBeacon and W ebBeacon element management software, or any standard SNMP-based management application.
8 Installation Guide Installation Guide * DIP switches can also be managed via console commands or through Metrobility NetBeacon or WebBeacon management software.
Radiance Multi-Rate Line Card 9 Configuring the Data Rate SW2 is used to set the initial data rate on the R380. The data rate is determined by the 6-bit binary code derived from the position of the DIP switches. The table below describes the settings supported by the multi-rate line card.
10 Installation Guide Loopback (LBCK) Switch Loopback is enabled independently on each port. When loopback is enabled, the port’ s transmitter is connected to its receiver , thus return- ing incoming data back to the sender . Use LBCK1 to set loopback on Port 1, and LBCK2 for Port 2.
Radiance Multi-Rate Line Card 11 Install the SFP Optics The R380 line card requires two small form-factor pluggable (SFP) optics. Optics are shipped separately . The table below lists the recom- mended optics to use based on the network protocol and fiber type.
12 Installation Guide MULTIRATE 1 2 LB BP PWR SD RX TX RX TX RX TX SEC LK AT LB BP SD IMPORT ANT : The multi-rate line card is designed and tested to operate using only Metr obility-supplied SFP transceivers. Safety , performance, and r eliability are guaranteed only when Metr obility- supplied transceivers ar e used.
Radiance Multi-Rate Line Card 13 5 • Insert the card into a slot on the chassis making sure that the top and bottom edges of the circuit board are aligned with the top and bottom card guides in the chassis. Do not force the card into the chassis unnecessarily .
14 Installation Guide Model # Fiber T ype Max Distance O21 1-40 ........................... singlemode ................................... 40 km O21 1-70 ........................... singlemode ................................... 70 km O21 1-1A .......
Radiance Multi-Rate Line Card 15 • The port’ s receiver detects the presence of optical power and the port’ s CDR circuitry has locked onto the incoming signal. For information on replacing the SFP transceiver, refer to Changing the SFP Optics .
16 User Guide User Guide This section contains information regarding the operating featur es of the Radiance multi-rate line card. LED Operation Several LEDs are visible on the front panel. These include the power (PWR), signal detect (SD), loopback (LB), and bypass (BP) LEDs.
Radiance Multi-Rate Line Card 17 SFP Monitors Advanced management capabilities on the Radiance multi-rate line card enables the monitoring of the following parameters for each SFP port transceiver with digital diagnostics.
18 User Guide Loopback The Radiance multi-rate line card features loopback testing capability to help verify proper operation and to isolate problems within a particular segment of the network.
Radiance Multi-Rate Line Card 19 Dual-Port Loopback In this mode, data on both ports of the multi-rate line card are looped back to their sending devices. Dual-port loopback is configurable through hardware or software by enabling loopback on Port 1 and Port 2 simultaneously .
20 User Guide Link Loss Return Both ports on the Radiance multi-rate interface line card are designed with Link Loss Return functionality for troubleshooting remote connections. When LLR is enabled * , the port’ s transmitter shuts down if its receiver fails to detect a valid link signal.
Radiance Multi-Rate Line Card 21 Link Loss Carry Forward The Radiance multi-rate line card incorporates LLCF to assist in troubleshooting a remote connection. When LLCF is enabled * , the ports do not transmit a signal until they receive a signal from the opposite port.
22 User Guide T opology Solutions Enterprise Switch Workgroup Hub Fiber Optic Links Copper Links Switch Switch PC running Network Management Software Servers Enterprise Radiance R5000 Central Service .
Radiance Multi-Rate Line Card 23 Central Office Drop & Insert Drop & Insert Drop & Pass Drop & Pass Drop & Pass Radiance R5000 with R380 Line Cards Radiance R4000 with 4-Channel CW.
24 User Guide Changing the SFP Optics The multi-rate line card supports two replaceable small form-factor pluggable (SFP) transceivers. This section explains how to remove and install the optics on the card. Metrobility SFP transceivers are hot-swappable.
Radiance Multi-Rate Line Card 25 T echnical Specifications Data Rate ____________________ 44.7 Mbps to 2.7 Gbps, depending on optics Power Requir ements _______________________________ 5 V DC @ 1 A, 5.
26 User Guide Multimode Fiber Optic Plug-in (O292-M5) Connector _____________________________________________________ LC W avelength _______________________________________________ 1310 nm Data Rate _.
Radiance Multi-Rate Line Card 27 Singlemode Fiber Optic Plug-in (O383-20-55) for BWDM Connector _____________________________________________________ SC TX W avelength ________________________________.
28 User Guide Singlemode Fiber Optic Plug-in (O21 1-70) Connector _____________________________________________________ LC W avelength _______________________________________________ 1550 nm Data Rate ____________________________________ 1.06 Gbps to 1.
Radiance Multi-Rate Line Card 29 Singlemode Fiber Optic Plug-in (O281-80) Connector _____________________________________________________ LC W avelength _______________________________________________.
30 User Guide Singlemode Fiber Optic Plug-in (O41 1-80-31 to -45) for CWDM Connector _____________________________________________________ LC W avelength __________________________________ (see tables on next page) Data Rate ____________________________________ 1.
Radiance Multi-Rate Line Card 31 s h t g n e l e v a W s c i t p O M D W C l e d o M r e b m u N h t g n e l e v a Ws r e b m u N l e d o Mh t g n e l e v a W 1 3 - 0 8 - 1 1 4 Om n 0 1 3 1 , 7 4 - 0 .
32 User Guide Acronyms and Abbreviations BP Bypass BWDM Bidirectional W avelength Division Multiplexing CDR Clock and Data Recovery CDRB Clock and Data Recovery Bypass CWDM Coarse W avelength Division.
Radiance Multi-Rate Line Card 33 Product Safety , EMC and Compliance Statements This equipment complies with the following requirements: •U L •C B • CSA • EN60950 (safety) • FCC Part 15, Cla.
34 User Guide Warranty and Servicing Three-Y ear W arranty for the Radiance Multi-Rate Line Card Metrobility Optical Systems, Inc. warrants that every Radiance multi-rate line card will be free from defects in material and workmanship for a period of THREE YEARS from the date of Metrobility shipment.
Radiance Multi-Rate Line Card 35 ADDITIONAL IMPOR T ANT W ARRANTY INFORMA TION: The Radiance multi-rate line card is designed to operate using only the Metrobility-supplied small form-factor pluggable (SFP) transceivers specified in this manual.
Product Manuals The most recent version of this manual is available online at http://www .metrobility .com/support/manuals.htm Product Registration T o register your product, go to http://www .metrobility .com/support/registration.asp 25 Manchester Street, Merrimack, NH 03054 USA tel: 1.
An important point after buying a device METRObility Optical Systems R380-SS (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought METRObility Optical Systems R380-SS yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data METRObility Optical Systems R380-SS - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, METRObility Optical Systems R380-SS you will learn all the available features of the product, as well as information on its operation. The information that you get METRObility Optical Systems R380-SS will certainly help you make a decision on the purchase.
If you already are a holder of METRObility Optical Systems R380-SS, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime METRObility Optical Systems R380-SS.
However, one of the most important roles played by the user manual is to help in solving problems with METRObility Optical Systems R380-SS. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device METRObility Optical Systems R380-SS along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center