Page 1 of the LST BC216-3 user manual — Description
Page 1 · click to enlarge
Page 1
LST BC216-3 — Control Panel Extension diagram (page 1)
Fig. 1 · Control Panel Extension

Control Panel Extension

LST BC216-3 — Control Panel Extension diagram (page 1)
Fig. 2 · Control Panel Extension
LST BC216-3 — Control Panel Extension diagram (page 1)
Fig. 3 · Control Panel Extension
LST BC216-3 — Control Panel Extension diagram (page 1)
Fig. 4 · Control Panel Extension

Bcnet216: BCE216-3LG

LST BC216-3 — Bcnet216: BCE216-3LG diagram (page 1)
Fig. 5 · Bcnet216: BCE216-3LG
  • BCnet sectional control panel with two integrated loop interfaces
  • Extends a BCnet sectional control panel BC216-2 or BC216-3 by two loops
  • Analogue ringbus technology with unshielded detector cabling
  • Easy installation, also possible later on

Fire is a permanent threat to life and property. There- fore, immediate response to a fi re is imperative. The main objective of the fi re detection control panel Series BC216 is to alarm and to react in time and, conse- quently, save lives and protect property. For decades LST have focused their aims to undertaking unrivaled efforts in order to realize new innovations in the security area. Research, development and production are loca-

ted within LST premises, thus guaranteeing fl exible and reliable individual solutions.

Using a 32-bit multiprocessor system, the fi re detection control panel Series BC216 ensures topmost effi ciency and speed – prerequisites for saving lives and minimi- zing damage to property.

LST BC216-3 — Bcnet216: BCE216-3LG diagram (page 1)
Fig. 6 · Bcnet216: BCE216-3LG

Description

The BCnet Sectional Control Panel/Extension BCE216- 3LG allows for the extension of a fi re detection control panel BCnet216 by two ADM loops. The extension is in- tegrated into the fi re detection control panel BCnet216 by installing it in a BCnet sectional control panel BC216- 2 or BC216-3 and connecting it to the GSSnet cabling via the GSSnet interface on the extension.

The loop processing functions of the BCE216-3LG fully correspond to the functions of a BCnet Sectional Con- trol Panel BC216-2 equipped with two Loop Interfaces LIF64-1.

The ADM loop principle offers intelligent analogue ring- bus technology with bi-directional data transfer. Each loop provides for the software-aided administration of up to 198 physical address points in a maximum of 128 detector zones.

The 24V supply of the BCnet Sectional Control Panel/Ex- tension BCE216-3LG is powered from the BCnet sectio- nal control panel in whose cabinet it has been installed; it does not have a power supply or battery charger of its own. The extension is designed as compact unit and mounted on a pivoting sheet steel carrier.

Easy parameterisation by means of PC software en- ables you to optimally adapt the control panel to your individual requirements.

BCE216-3LG_DBL_LST_EN_0804.PDF • PAGE 1 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED
Page 2 of the LST BC216-3 user manual — Clear Concept
Page 2 · click to enlarge
Page 2
LST BC216-3 — Clear Concept diagram (page 2)
Fig. 7 · Clear Concept

Clear Concept

The BCnet Sectional Control Panel/Extension BCE216-3LG extends a BCnet sectional control panel BC216-2 or BC216-3, respectively, by two ADM loops. It provides the following features:

  • At a possible breakdown of the central processing unit which is integrated on the extension, the diversifi ed redundancy concept ensures secure alarm recognition.
  • The parameter data can be created by means of the PC software PARSOFT and loaded into the control panel in a comfortable way. Thus, a quick and effi cient transfer of the system confi guration into the control panel is guaranteed.
  • AUTO setup facilitates parameterisation when the control panel is commissioned or expanded and thus helps to save time.
  • Detectors and modules in ADM loop technology can be connected to each Loop Interface LIF64-1. Depending on the parameterisation, either the Apollo/Discovery protocol or the System Sensor/200 protocol is used to achieve bi-directional data transfer.
  • Logical combinations of detectors and detector zones for the activation of external controls and alarming devices facilitate maximum fl exibility. Thus, no additional expenses arise for external relays, logic gates or timers. Thanks to the wide range of parameterisation possibilities, individual requirements even under the most diffi cult ambient conditions can be combined into a reasonable fi re protection strategy.
  • By integrating input and output modules on any position in the loop you can realize enablements or disablements as well as control tasks in your system without having to care for additional wires.
  • The free combination of detectors and modules into logic sectors allows for the joint operation of defi ned parts of the system even beyond the limits of loops or sectional control panels.
  • The use of unshielded loop cables allows for costsaving and uncomplicated installation as well as for the possibility of reusing the existing cabling.

The BCnet Sectional Control Panel/Extension BCE216-3LG is suitable for later installation in the wall mount cabinet.

Owing to the compact design, a maximum of four loops can be centralized in one single place. The required bat- teries are accommodated in the wall mount cabinet or in an external auxiliary case. Series BC216 thus stands for modularity and easy expansion.

This product complies with all relevant standards of EN 54 and is VdS-certifi ed. In addition, the product also holds several country-specifi c approvals and certifi ca- tes. LST‘s high quality level is secured by a permanent- ly monitored quality management system certifi ed by ISO 9001.

BCE216-3LG_DBL_LST_EN_0804.PDF • PAGE 2 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED
Page 3 of the LST BC216-3 user manual — Permanent Connection
Page 3 · click to enlarge
Page 3

Permanent Connection

By means of a BCnet Sectional Control Panel/Extension

loops. In one case, you thus have up to four loops at your disposal. In addition, a variety of peripheral de- vices can be connected to this device:

BCE216-3LG, a Fire Detection Control Panel BC216-2 or BC216-3, respectively, can be extended by two

  • Fire brigade key safe
  • Fire brigade control unit
  • Acoustic and optical signaling devices
  • External protocol printer
  • Remote display and operating panels
  • Remote indication unit
  • Actuations
  • Electronic monitoring system
  • Transmitting device for the actuation of pagers via ESPA protocol
  • Modules for remote parameterisation and remote maintenance via computer newtork, modem or GSM connection
  • Transmitter module for the transmission of messages via SMS or e-mail – and much more.
LST BC216-3 — Permanent Connection diagram (page 3)
Fig. 8 · Permanent Connection

BCE216-3LG_DBL_LST_EN_0804.PDF • PAGE 3 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED
Page 4 of the LST BC216-3 user manual — Specifi cations
Page 4 · click to enlarge
Page 4

Distributed Intelligence in the GSSnet

The fi re detection control panel BCnet216 opens up ma- nifold possibilities for the realization of specifi c requests of fi re detection, especially in spacious buildings, high- rise buildings or wide-stretched areas. The decentralized security network that has been crea- ted by BCnet216 offers increased security and reduces the total expenses due to a much lower cabling volume. The consistent ring-shaped cabling guarantees commu- nication between the sectional control panels even in the event of a line fault.

Cabling of the detectors is required only between two neighboring sectional control panels. This clear and fl exible arrangement of the sectional control panel cre- ates a powerful network. In this way, most economical cabling and thus effi cient use of the installation expen- ses is guaranteed. Larger distances between individual sectional control panels can be bridged through the use of optical fi ber modems or long distance modems.

The entire virtual control panel BCnet216 provides for the monitoring in mid-sized and large systems, applying the same technology and the same software tools as with the single control panel BC216-1. This guarantees a minimum of training and expansion costs as well as expenses of the user and thus guarantees the optimal use of resources during the usable life of the building.

A sectional control panel of the BCnet216 is parame- terised as main operating unit for the administration of the GSSnet, all other members can be equipped with or without a display and operating unit. The system is designed modularly and can be gradually expanded according to future demands. The maximum size of a BCnet216 comprises 127 network members, 9700 detector zones, 9700 actuations, 999 alarming devices, 99 transmitting devices as well as 199 logic sectors. Different interfaces are available for the con- nection of external information devices, e.g., a facility management system or a remote maintenance sys- tem.

BCnet sectional control panels are available in wall mount cabinets, as 19“ compact version and in 19“ slide-in technology.

LST BC216-3 — Distributed Intelligence in the GSSnet diagram (page 4)
Fig. 9 · Distributed Intelligence in the GSSnet

Extinguishing Control System

If required, the BCnet216 can be easily expanded to an extinguishing control panel LCnet216 according to EN 12094-1. The panel can control up to 127 fl ooding zones in a maximum of 127 extinguishing systems. The function of the extinguishing control panel is fully in- tegrated into the fi re detection control panel BCnet216, a combined operation is therefore possible.

The LCnet216 is certifi ed to EN 54-2, EN 54-4, EN 12094-1 and VdS as a pure extinguishing control panel and as a combined fi re detection and extinguis- hing control panel. Optionally, the LCnet216 can be implemented with full hardware redundancy.

LST BC216-3 — Extinguishing Control System diagram (page 4)
Fig. 10 · Extinguishing Control System

Specifi cations

Supply voltage 21 – 30 VDC

Current consumption at 24V 140mA (without detectors)

Idle loop current typ. 300µA per detector/module

Total loop current max. 300mA (at reduced line resistance)

Idle loop voltage typ. 26V (Apollo/Discovery) or typ. 29V (System Sensor/200), respectively

Loop line resistance max. 50Ω per core

Number of ADM loops 2

Number of detector zones max. 128 per loop, max. 144 in total

Ambient temperature -5°C to +50°C

Dimensions W × H × D 248 × 222 × 28 (mm)

Weight approx. 675g

Part No. 214034

Order name BCnet Sectional Control Panel/Extension BCE216-3LG

BCE216-3LG_DBL_LST_EN_0804.PDF • PAGE 4 A Building Safety. Building Security.

  • © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH
  • A-1231 WIEN
  • WIEGELESTRASSE 36
  • TEL +43 1 52114-0
  • FAX +43 1 52114-27 [email protected]
  • <a href="http://WWW.LST.AT" rel="nofollow noopener" target="_blank">WWW.LST.AT</a>
  • ALL RIGHTS RESERVED
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the LST BC216-3

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the LST BC216-3

Be the first to ask — other owners or our team will answer.

Original document

LST BC216-3 manual PDF

4 pages·353 KB·Network Card·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…