Time Zones The RE-1 contains an internal clock and calendar. Seven programmable “time zones” allow setting time periods to schedule system functions. Each time zone can be active or inactive on certain days. Keypad entry codes, wireless transmitters, automatic access control, call forwarding, and the “Do Not Disturb” feature can each be set to only be active during a specifi c time zone period. Up to ten “holiday” days can be programmed. Each of the seven time zones can be set to be active or inactive during a holiday.
Linear’s RE-1 Telephone Entry System is designed for residential or light commercial access control applications. The speakerphone, keypad, radio receiver, and optional video camera are housed in a rugged enclosure that can be mounted to a pedestal or bolted directly to a wall. The die-cast keypad keys have bright, easy-to- read graphics and are lit with an overhead light. The two operation buttons; CALL and HELP, are machined for heavy-duty reliability.
Arriving visitors will approach the unit and place a call to the residence by pressing the CALL button. The RE-1 will acquire the residence’s local telephone line and generate distinctive rings to the house telephones. The resident, knowing that the distinctive ring is originating from the access area, can answer any house telephone and converse with the visitor. If the resident decides to grant access to the visitor, they can activate either output relay in the RE-1 by pressing a key on the telephone’s keypad. If the resident decides not to grant access, hanging up or pressing a key will disconnect the visitor’s call.
Portal Supervision The SENSE/INHIBIT input can be used two ways. If programmed for “door sense”, a switch on the door detects forced entry or door ajar situations. If programmed for “inhibit”, the input can be wired to a “service” switch or automatic timer that will disable the Relay #1 when required.
Hardwired Activation The OPEN REQUEST input can be wired to an exit loop detector or exit photo beam to allow automatic exit activation. An emergency access keyswitch can be mounted in the RE-1 case to allow keyed entry for authorized personnel.
Call Waiting If the resident is using the telephone at the time a visitor calls, the RE-1 will sound beeps on the telephone line to announce that a visitor is calling. The resident can press a key on the telephone to place the outside caller on hold and communicate with the visitor. After granting or denying access to the visitor, the outside caller will be re-connected to the resident.
Access Security The “anti-passback” feature allows the option of preventing the use of the same code or the same transmitter again before the programmed time elapses. The “keypad lockout” feature discourages tampering by disabling the keypad for one minute after a programmable number of incorrect entry codes has been entered at the keypad.
Call Forwarding Programmable call forwarding allows the RE-1 to dial any selected telephone number when a visitor presses the CALL button. For example, with call forwarding enabled, the RE-1 could dial a cell phone to contact the resident while outside or away from the residence. The resident will be able to communicate with the visitor and grant or deny access from the remote telephone.
Event Log An access log of up to 450 events is stored in the unit’s memory. System activity is logged as it occurs with the date and time of the event. The access log data can be retrieved locally or remotely with a computer through the RE-1’s built-in modem.
Local & Remote Programming The system’s built-in programming software can be accessed on-site or off-site using a computer with any Internet browser. The software’s graphic display of each of the programming steps make programming easy. Without a computer, the RE-1 can be programmed with its main keypad, from any local telephone connected to the same line, or by calling from any remote telephone. The EEPROM memory retains all entry codes, transmitter information, and programming, even without power.
Alternate Numbers For installations where multiple residences exist inside the same controlled opening (such as a guest house or granny fl at) three alternate calling numbers can be programmed. The alternate numbers can be called by entering a short code at the keypad.
Local Control The resident can issue control commands from the local telephones without a call from a visitor. By dialing a specifi c series of digits, the resident can control either of the two relays. The resident can also initiate voice communications with the entry system.
Obstacle Detection Linear’s Model MGT safety edge transmitter is compatible with the RE-1 This MGT detects and transmits obstacle events to the RE-1 receiver. Obstacle signals from an MGT transmitter will activate Relay #2.
Up to 100 entry codes, from 1 to 6 digits in length, can be programmed. Each entry code can activate either, or both, of the relay outputs. Linear’s Model AM-KP keypad can be used as a secondary remote keypad for the RE-1. Up to 24 sets of block coded MegaCode® transmitters (up to 100 transmitters total) can be used to gain access through the RE-1’s built-in radio receiver. Each transmitter can be individually suspended or re-activated. One facility code can be programmed to identify each block of transmitters. Programming of individual (non-block coded) transmitters is not supported by the RE-1.
Alarm Interface Relay #2 can be programmed for alarm shunt to bypass an alarm loop during entry, or alarm trigger to cause an alarm during forced entry. Four activation options are available for Relay #2.
Voice Synthesizer A built-in voice synthesizer sounds voice prompts through the speaker, local and remote telephones.

The quality of the system’s audio communications is related to the type of telephone wire and its installation. Noise and hum can be introduced into the telephone wires. Use only high-quality telephone wire rated for direct underground burial. All telephone wire should be twisted-pair.
Before beginning installation, please review the entire instructions and become familiar with the system’s operation, wiring, and programmable options.
For pedestrian door or gate installations, mount the Entry System on a rigid wall near the controlled door. Avoid mounting the unit in a location where regular mechanical shock will occur due to a slamming door or spring loaded pedestrian gate. For vehicular gate installations, mount the Entry System in clear view of the gate, but far enough from the gate so the user cannot touch the gate from the keypad.
Use the supplied 16-volt 20-VA transformer to power the RE-1. DO NOT POWER ANY OTHER EQUIPMENT FROM THE SAME TRANSFORMER, use a separate power supply. Keep the system power wires as short as practical to reduce the chance of noise and hum pickup.
SERIOUS INJURY OR DEATH, MAKE SURE THAT THE UNIT IS FAR ENOUGH FROM THE GATE SO THAT THE USER CANNOT TOUCH THE GATE WHILE OPERATING THE KEYPAD. HOWEVER, FOR SAFETY, THE GATE MUST BE FULLY VISIBLE FROM THE KEYPAD.
An in-line ferrite RFI fi lter has been included with this unit to install during the wiring of the RE-1 Residential Telephone Entry System.
must be performed at the time the RE-1 is installed. 1. Open the ferrite RFI fi lter case by gently pulling on the side locking tab and swinging the case open (see Figure 1). ★ CAUTION: The ferrite parts of the RFI fi lter are fragile.
To avoid damage to the unit from static discharges, connect the RE-1’s EARTH GROUND and case ground terminals to a good earth grounding point within 10 feet. The case ground terminal is the #8 screw located on the backplate above the wire entry hole. Also, the RE-1’s Telephone Bypass Module must be grounded to provide surge protection for the telephone line. Suggested wiring size is 12 AWG for earth ground.
DO NOT DROP THE FILTER ON A HARD SURFACE! Damage to the fi lter may result. 2. After completing the RE-1 installation, route all wires except the AC transformer and telephone lines through the grove in the ferrite core of the RFI fi lter. The fi lter must be installed outside of the RE-1 case. With the wires captured inside, close the ferrite RFI fi lter case and snap it shut (see Figure 1). ✦ NOTE: Be sure the fi lter is located no further than two inches from the
For convenience, the RE-1 is provided with removable terminal strips. It is important that these strips be removed evenly in order to avoid causing permanent damage to them.
rear case cover of the RE-1.
SWING FILTER CASE OPEN
wires.
FERRITE CORE
Figure 1. RFI Filter Installation



12 RELAY TERMINAL BLOCK For Relay #1 and Relay #2 output connections to the access control devices.
1 KEYPAD Die-cast metal 12-key keypad with tactile action. For system programming and keying in entry codes.
13 RELAY INDICATORS Indicators for Relay #1 and Relay #2 will light when the relay is activated.
2 DOWNLIGHT Illuminates keypad and visitor operation buttons. The light can be programmed to operate dusk to dawn and adjusts its time depending on the system’s geographic location.
14 ANTENNA TERMINAL BLOCK For shield and center conductor connection of the coax cable from the system’s built-in radio antenna.
3 OPTIONAL CCTV CAMERA Location for the optional Model RE-BWC1 CCTV camera. The camera views the keypad area and has infrared lighting for nighttime use.
15 LINE MONITOR JUMPER For testing and troubleshooting. Remove jumper to listen to telephone line audio through the speaker.
4 MICROPHONE The high-sensitivity microphone monitors sound at the keypad area for the entry system’s speakerphone.
16 DIGITAL SPEECH VOLUME CONTROL Controls the audio level of the voice synthesizer. This adjustment effects the audio level of the voice synthesizer and system tone from the speaker.
5 CALL BUTTON Pressing this button causes the system to call the residence telephones with a distinctive ring signal.
17 STATUS INDICATORS Six indicators light to display system power, radio, and modem status.
6 HELP BUTTON Pressing this button causes the system to play the help message to instruct the visitor on system use.
18 VIDEO CONNECTOR For cable connection to a video monitor. (Optional Model RE-BWC CCTV camera required).
7 SPEAKER Weatherproof speaker for system operation and programming.
19 CAMERA CONNECTOR Provides power and video connection for the optional Model RE- BWC CCTV camera.
8 INTEGRAL ANTENNA Hidden antenna receives wireless radio signals from transmitters.
9 OPTIONAL KEYLOCK Location for mounting access keylock. (MEDECO keylock with stainless steel cover shown).
20 RESTART BUTTON Pressing this button restarts the system. This button DOES NOT erase any programming data.
10 MAIN TERMINAL BLOCK For power, backup battery, sense inputs, open request inputs, and remote keypad connections.
21 TELEPHONE TERMINAL BLOCK For telephone line and earth ground connections.
11 SPEAKERPHONE VOLUME CONTROL Controls the audio level produced by the speaker during communications between the visitor and the resident.


3 AMPS AT 30 VOLTS AC OR DC MAXIMUM
3 AMPS AT 30 VOLTS AC OR DC MAXIMUM
STAKE

TELEPHONE WIRING
The RE-1 connects between the incoming telephone line of the residence and local telephone sets.
The RE-1 Entry System can be mounted on a standard pedestal. 1. Open the RE-1 case by removing the two security screws with the wrench provided (see Figure 2). 2. Use four security bolts and locking nuts to secure the backplate to the pedestal (see Figure 3).
The RE-1’s Telephone Bypass Module provides surge protection and a switch to remove the RE-1 from the telephone line and re-connect the local telephones to the telephone system. ALL TELEPHONE WIRING FOR THE RE-1 MUST PASS THROUGH THE BYPASS MODULE. The bypass module is housed in a weather-resistant enclosure and should be located in an area that is easily accessible to the resident. In case of system trouble, the resident can use the bypass switch to remove the RE-1 from the telephone system.
The RE-1 Entry System can be mounted directly to a wall or fl at surface. 1. Open the RE-1 case by removing the two security screws with the wrench provided (see Figure 2). 2. Use the appropriate fasteners to secure the system’s backplate to the mounting surface. When mounting the system to a concrete wall, use concrete wedge anchors (see Figure 4).
REMOVE THE TWO SECURITY SCREWS TO OPEN THE CASE
1. Connect the bypass module’s EARTH GROUND terminal to a good earth ground. 2. Before connecting the incoming telephone line to the bypass module check the polarity of the wires with a DC voltmeter. Connect the negative wire (RING - usually green) to the bypass module TELCO RING terminal. Connect the positive wire (TIP - usually red) to the bypass module TELCO TIP terminal. 3. Connect the resident’s local telephone line RING (usually green) to the bypass module HOUSE RING. Connect the local telephone line TIP (usually red) to the bypass module HOUSE TIP terminal. 4. Connect the RE-1 TELCO RING to the bypass module RE-1 TELCO RING terminal. Connect the RE-1 TELCO TIP to the bypass module RE-1 TELCO TIP terminal. 5. Connect the RE-1 HOUSE RING to the bypass module RE-1 HOUSE RING terminal. Connect the RE-1 HOUSE TIP to the bypass module RE-1 HOUSE TIP terminal.
Figure 2. Opening the RE-1 Case
PEDESTAL MOUNTING MOUNT BACKPLATE WITH SECURITY BOLTS AND LOCKNUTS
PEDESTAL CAUTION! BE SURE THE MOUNTING HARDWARE DOES NOT EXTEND MORE THAN 1/2" INSIDE THE BACKPLATE OR ELECTRICAL DAMAGE MAY OCCUR
Figure 3. Pedestal Mounting Backplate
BYPASS MODULE
EARTH
RE-1 ENTRY SYSTEM
TIP
TELCO
RING
CASE GROUND
TIP
HOUSE
RING
WALL MOUNTING
CASE GROUND SCREW
TO HOUSE
RING
PHONES
TIP
HOUSE
RING
RE-1 HOUSE
TIP
TELEPHONE
BYPASS MODULE
RING
RE-1 TELCO
USE WEDGE ANCHORS FOR CONCRETE OR OTHER APPROPRIATE ANCHORS FOR DIFFERENT MATERIALS
EARTH GROUND
GROUND
RING
STAKE
LINE
TELCO
TIP
Figure 5. Telephone Wiring
Figure 4. Wall Mounting Backplate

Shared Line
Pressing the Call button on the RE-1 will cause the RE-1 to generate a ring signal as if it were an intercom station. A live phone line is not used and the RE-1 provides power for the remote intercom phone.
This is the standard confi guration. The telephone line is routed through the RE-1 to the house phones. Pressing the Call button on the RE-1 will cause the RE-1 to disconnect the house phones from the telephone company line and generate a ring signal that is heard on the house phones.
resident calling is not available.
See PPN #52 for programming options.
TO HOUSE INTERCOM TELEPHONES
RING
HOUSE
RE-1 ENTRY SYSTEM
TIP
RING
RE-1 HOUSE
TO HOUSE
RING
TIP
TELEPHONE
PHONES
TIP
HOUSE
BYPASS MODULE
RING
RING
RE-1 TELCO
RE-1 HOUSE
TELEPHONE
TIP
EARTH GROUND
BYPASS MODULE
RING
RING
RE-1 TELCO
STAKE TIP
TELCO
TIP
EARTH GROUND
GROUND
FROM TELEPHONE
RING
TELCO
COMPANY
TIP
EARTH
RE-1 ENTRY SYSTEM
10' MAXIMUM WIRE RUN
TIP
10' MAXIMUM WIRE RUN
RING
TELCO
GROUND
GROUND
CASE GROUND
STAKE
STAKE
TIP
HOUSE
RING
Figure 6. Shared Line Wiring
Figure 8. Intercom Mode Wiring
Pressing the Call button on the RE-1 will cause the RE-1 to sieze the phone line and dial out to an outside number.
Pressing the Call button on the RE-1 will cause the RE-1 to sieze the phone line and provide immediate communications with the PBX system.
See PPN #54 for programming options.
See PPN #54 for programming options.
RE-1 ENTRY SYSTEM
TO PBX SYSTEM
RING
RING
HOUSE
TIP
HOUSE
TIP
RING
RING
RE-1 HOUSE
RE-1 HOUSE
TELEPHONE
TIP
TELEPHONE
TIP
BYPASS MODULE
BYPASS MODULE
RING
RE-1 TELCO
RING
RE-1 TELCO
EARTH GROUND FROM TELEPHONE
TIP
TIP
EARTH GROUND
RING
RING
TELCO
TELCO
COMPANY
TIP
STAKE TIP
GROUND
RING
TIP
RING
TIP
EARTH
10' MAXIMUM WIRE RUN
HOUSE
TELCO
10' MAXIMUM WIRE RUN
GROUND
GROUND
EARTH
RE-1 ENTRY SYSTEM
STAKE
STAKE
TIP
TELCO
Figure 7. Dedicated Line Wiring
CASE GROUND
TIP
RING
HOUSE
Figure 9. Ring Down Mode Wiring


1. Install a low voltage electric door strike or magnetic lock as a locking device for the door or pedestrian gate. 2. Install the power supply or transformer for the locking device. DO NOT POWER THE RE-1 FROM THIS POWER SUPPLY. 3. Connect one wire from the power supply to one wire from the locking device. 4. Route two wires between the locking device and the RE-1. Connect one wire to the remaining wire of the locking device. Connect the other wire to the remaining wire of the power supply. • For a door strike, connect the wires to the RE-1 Relay #1 COM & N.O. terminals.
diagram. 2. If an access keyswitch is required refer to the Optional Keyswitch section of this manual for details on keyswitch wiring and installation. 3. If an external timer for preventing access at certain times is required, route two wires from the RE-1 to the timer contacts. Connect the timer contacts to the RE-1 SENSE #1 and COMMON terminals. ✦ NOTE: If the sense input is going to be used as an inhibit input, it must
be programmed to select that input type. See programming PPN #29.
2 WIRES FOR DOOR SENSE SWITCH
4 WIRES FOR TELEPHONE
DOOR SENSE SWITCH
RE-1 ENTRY SYSTEM
ELECTRIC DOOR STRIKE
2 WIRES FOR RE-1 POWER FROM TRANSFORMER
2 WIRES FOR DOOR STRIKE
NOTE: ROUTE TELEPHONE WIRES AWAY FROM POWER WIRES
2 WIRES FROM RE-1 TO GATE OPEN TERMINALS
2 WIRES FROM TRANSFORMER FOR RE-1 POWER
2 WIRES FOR DOOR STRIKE POWER FROM POWER SUPPLY
Figure 13. Door Installation Example Figure 11. Gate Installation Example
RELAY
RELAY
RELAY
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
N.O.
N.C.
ELECTRIC DOOR STRIKE
RE-1 TERMINALS
RE-1 TERMINALS
REQUIRED WIRING
DOOR STRIKE POWER SUPPLY
TRANSFORMER
TRANSFORMER
TRANSFORMER
OPTIONAL WIRING
TRANSFORMER
BATTERY NEGATIVE
BATTERY NEGATIVE
REQUIRED WIRING
BATTERY POSITIVE
INHIBIT
BATTERY POSITIVE
SENSE #1
SENSE #1
OPTIONAL WIRING
OPEN #1
OPEN #1
SENSE #2
SENSE #2
OPEN #2
ACCESS KEYSWITCH
OPEN #2
DOOR SENSE SWITCH
COMMON
COMMON
KEYPAD CLK
KEYPAD CLK
KEYPAD DVAL
KEYPAD DVAL
KEYPAD DAT 0
KEYPAD DAT 0
ACCESS KEYSWITCH
KEYPAD DAT 1
KEYPAD DAT 1
KEYPAD GND
KEYPAD GND
KEYPAD PWR
KEYPAD PWR
Figure 12. Gate Installation Wiring
Figure 14. Door Installation Wiring

OPTIONAL REMOTE KEYPAD
The optional Model AM-KP remote keypad can be used with the RE-1 entry system. A typical application for the remote keypad would be to control a second door or gate. Entry codes are the only method of access allowed at a remote keypad. The default system setting will cause the remote keypad to activate Relay #2. 1. Mount the AM-KP keypad onto a pedestal or to a wall. 2. Route 6-conductor cable from the RE-1 to the AM-KP. • For wire runs up to 300 feet use 24 AWG Belden Type 9931 or equivalent.
COMPLETE. 1. Route two wires between the RE-1 and the power transformer. • For power wire runs up to 100 feet, use 18 AWG, THHN 600-volt insulated wire.
Use of battery backup is optional. It will allow the RE-1 to operate for short periods of time without AC power. Two 12-volt backup batteries in series are recommended to obtain the proper working voltage for the RE-1. A single 12-volt battery can be used, although the call waiting beeps and the ring voltage will be lower than normal when fi ve telephones are connected. The door or gate access device must use some type of battery backup for the entire system to be functional. Backup batteries will not fi t into the RE-1 housing. Protect the backup batteries inside a rain-tight NEMA enclosure suitable for the installation.
calendar and programming memory during power outages. 1. Route two wires between the RE-1 and the backup batteries. 2. Connect two 1.2 Amp/hour (minimum), 12-volt, gel cell batteries in series (Battery #1 negative to Battery #2 positive). 3. Connect the Battery #1 positive to the RE-1 BATTERY POSITIVE terminal. 4. Connect the Battery #2 negative to the RE-1 BATTERY NEGATIVE terminal. ✦ NOTE: The RE-1 does not supply battery charging current. An
external battery charger will be required to maintain the batteries.
For the best ground, use size 12 gauge solid wire or larger to connect the to an 8-foot copper ground rod. Locate the ground rod next to the Power and Telephone company rods and bond the rods together with a new clamp. Do not disturb the clamps installed by the Power or Telephone Company. Alternately, connect to a cold water pipe for the earth ground. 1. Connect the RE-1 EARTH terminal to the earth ground wire. 2. Connect the Telephone Bypass Module EARTH GROUND terminal to the earth ground wire.
Figure 16. Setting the Keypad Device Address
RE-1 TERMINALS
TRANSFORMER
RE -1 TRANSFORMER
TRANSFORMER BATTERY NEGATIVE
TRANSFORMER BATTERY NEGATIVE
BATTERY POSITIVE
12 VOLT 1.2 AMP/HR BATTERY
12 VOLT 1.2 AMP/HR BATTERY
SENSE #1
USE BELDEN 9931 (24 AWG) CABLE FOR RUNS UP TO 300 FEET
SENSE #1
NOTE: BACKUP BATTERIES WILL REQUIRE AN EXTERNAL CHARGER
SENSE #2
OPEN #1
USE WEICO 9405 (20 AWG) CABLE FOR RUNS UP TO 500 FEET
RING
SENSE #2
COMMON
HOUSE
KEYPAD CLK
TIP
OPEN #2
RING
KEYPAD DVAL
RE-1 HOUSE
COMMON
KEYPAD DAT 0
TIP
TELEPHONE
KEYPAD CLK
CLK
RING
BYPASS MODULE
KEYPAD DAT 1
RE-1 TELCO
KEYPAD DVAL
DVAL
KEYPAD GND
TIP
EARTH GROUND
RING
KEYPAD DAT 0
DAT0
AM-KP REMOTE KEYPAD
KEYPAD PWR
TELCO
TIP
KEYPAD DAT 1
DAT1
RE-1 TERMINALS
RING
TIP
RING
TIP
EARTH
KEYPAD GND
GND
HOUSE
TELCO
GROUND
KEYPAD PWR
PWR
STAKE
Figure 15. Power, Backup Battery & Ground Wiring
Figure 17. Remote Keypad Wiring

A keyswitch can be installed in the RE-1 Entry System to provide keyed access. The RE-1 case is designed to accept the following keyswitch:
KNOX COMPANY
800-552-5669 www.knoxbox.com
Keyswitch Installation
1. Disconnect the wiring harness connector and remove the antenna terminal block. Remove the four circuit board retaining screws and the RE-1 circuit board (see Figure 18). 2. Remove the screw and washer that retain the keyswitch hole access plate (see Figure 19). 3. Hold the lock cover and plastic spacer in place on the RE-1 case. Secure the assembly with four screws, lock washers, and nuts. Slide the keyswitch into the hole, oriented as shown (see Figure 20). Secure the keyswitch with the large switch nut. Use bolt cutters to trim the two screws closest to the case edge so they will clear the circuit board (see Figure 21). 4. Plug the two keyswitch snap-on wire leads (supplied with the switch) onto the keyswitch COM and N.O. pins (see Figure 21). 5. Replace the RE-1 circuit board. Secure the board with the four screws. Reconnect the antenna terminal block and wiring harness connector. 6. Connect one keyswitch wire to the RE-1 OPEN #1 terminal. Connect the other keyswitch wire to the RE-1 COMMON terminal.
INSTALL COVER PLATE AND SPACER WITH FOUR SCREWS, LOCKNUTS, & NUTS
SPACER
INSERT KEYSWITCH INTO HOLE WITH KEYSLOT ORIENTED AS SHOWN
Figure 20. Installing the Keyswitch
COM
REMOVE CIRCUIT BOARD
N.O. SWITCH PINS
SWITCH SECURED WITH LARGE NUT BOLTS CUT SHORT TO CLEAR CIRCUIT BOARD
REMOVE THESE 4 SCREWS
Figure 18. Removing the RE-1 Circuit Board
Figure 21. Keyswitch Wire Connections
TRANSFORMER
RE-1 TERMINALS
TRANSFORMER
BATTERY NEGATIVE
BATTERY POSITIVE
SENSE #1
OPEN #1
SENSE #2
OPEN #2
ACCESS KEYSWITCH
COMMON
KEYPAD CLK
KEYPAD DVAL
KEYPAD DAT 1
REMOVE THE COVER PLATE
KEYPAD GND
KEYPAD PWR
Figure 22. Keyswitch Wiring Figure 19. Removing the Keyswitch Hole Access Plate

Linear’s Model RE-BWC1 (P/N ACP00886A) CCTV camera can be installed inside the RE-1 Entry System. The camera provides a video signal for viewing the area in front of the entry system. The camera is continuously powered by the RE-1. The camera’s infrared light emitters illuminate the area directly on front of the entry system for nighttime or low light operation. The RE -1 CAMERA jack is used to connect the camera to the main circuit board with the double-ended modular cable supplied with the camera. This cable routes power to, and video from the camera. The RE-1 VIDEO jack is for connection to a video cable with a Type “BNC” connector. Up to 300 feet of 75-ohm RG-59 video cable can be used. Longer cable runs may require the use of a video amplifi er.
1. Disconnect the wiring harness connector and remove the antenna terminal block. Remove the four circuit board retaining screws and the RE-1 circuit board (see Figure 23). 2. Mount the camera assembly into the RE-1 case. Secure the camera with the two screws provided (see Figure 24). 3. Connect the wiring harness 2-pin lighting power wiring connector onto the camera’s infrared lighting power connector (see Figure 25). 4. Replace the RE-1 circuit board. Secure the board with the four screws. Reconnect the antenna terminal block and wiring harness connector. 5. Plug the double-ended modular cable into camera’s jack and the RE-1 CAMERA jack (see Figure 26). 6. Connect the video cable to the RE-1 VIDEO connector (see Figure 27).
INSERT WIRING HARNESS PLUG INTO THE 2-PIN LIGHTING CONNECTOR
Figure 25. Connecting the Camera’s Lighting Power
PLUG THE CAMERA CABLE INTO THE CAMERA'S JACK AND THE RE-1'S CAMERA JACK
CAMERA CABLE FROM CAMERA'S JACK
RE-1 CAMERA
JACK
REMOVE THESE 4 SCREWS
Figure 26. Connecting the Camera Cable
Figure 23. Removing the RE-1 Circuit Board
CONNECT THE VIDEO CABLE FOR THE MONITOR TO THE RE-1'S VIDEO OUTPUT CONNECTOR
TO PREVENT INTERNAL INFRARED LIGHT FROM ENTERING THE CAMERA, BE SURE THE FOAM GASKET AROUND THE CAMERA'S LENS PRESSES FIRMLY AGAINST THE RE-1'S FACEPLATE
Figure 24. Mounting the Camera in the RE-1
Figure 27. Connecting the Video Cable

3. Double-click on “Local RE-1”. (The Local RE-1 icon can be dragged to the desktop for easy future access). 4. Enter the RE-1’s programming master password (123456, unless changed) into the “Password” area. Select “Save Password” if you want the computer to retain the password. 5. Select “Connect” and wait for the modem to connect to the RE-1. 6. Switch to the browser software and enter into the address line: “http://192.168.20.10/re1.html” (save this address as a “favorite” or “bookmark” so you won’t have to enter it each time you connect). 7. Follow the screen links to select the RE-1 items to program. 8. When fi nished programming, double-click on the dial-up networking icon in the status area of the task bar and select “Disconnect” to terminate the connection. ✦ NOTE: Be sure to disconnect when programming is completed.
The RE-1 can be programmed locally or remotely. The system’s built-in programming software can be accessed on-site or off-site using a computer with any Internet browser. Without a computer, the RE-1 can be programmed from its main keypad, from any local TouchTone® telephone connected to the same line, or from any remote TouchTone® telephone by calling the unit. To guide you through the programming, the RE-1’s voice synthesizer will announce programming prompts over the telephone.
Navigating through the RE-1’s programming “pages” is similar to browsing through your favorite web site’s pages. Anyone familiar with the Internet will fi nd programming the RE-1 with a computer very easy. The RE-1’s memory contains the “pages” that the computer will view. When selections and changes are made on the computer, the RE-1’s memory is programmed to your custom settings.
Creating Remote Computer Dial-up Connection 1. From “My Computer” select “Dial-up Networking” and select “Make New Connection”. 2. Name the connection “Remote RE-1” and verify that the installed modem is listed as the device the select “Next”. 3. For the telephone number enter the telephone number of the line that the RE-1 is installed on, select “Next”, then select “Finish”. 4. Right-click on “Remote RE-1” and select “Properties”. 5. From the “General” tab, in the “Connect Using” area, select “Confi gure...”. 6. From the “General” tab, in the “Speaker volume area”, set the volume to “High”. 7. Select the “Connection” tab. 8. Select “Advanced...” 9. In the “Use error control” area, de-select “Compress data” and select “OK” 10. Select “OK” again. 11. Select the “Server Types” or “Networking” tab. 12. In the “Advanced Options” area, de-select “Enable software compression”. 13. In the “Allowed network protocols” area, de-select “NetBEUI” and de-select “IPX/SPX Compatible”. Only “TCP/IP” should be selected. 14. Select “TCP/IP Settings...”. 15. Select “Specify an IP address”. 16. Enter “192.168.20.11” as the “IP address”. 17. De-select “Use IP header compression” and de-select “Use default gateway on remote network” then select “OK”. 18. Select “OK” again to complete the properties settings. Connecting Remotely 1. Start your browser software. If your browser is set to automatically dial your normal Internet provider when the browser is opened, cancel the dialing when it starts. 2. From “My Computer” select “Dial-up networking”. 3. Double-click on “Remote RE-1”. (The Remote RE-1 icon can be dragged to the desktop for easy future access). 4. Enter the RE-1’s programming master password (123456, unless changed) into the “Password” area. Select “Save Password” if you want the computer to retain the password. 5. Select “Connect” and wait for the modem to dial the RE-1. 6. Select “Cancel” after two rings. 7. Wait about 10 seconds, but not longer than 30 seconds, then repeat Steps 3-5. The RE-1 should answer. 8. Wait for the connection to establish. 9. Switch to the browser software and enter into the address line: “http://192.168.20.10/re1.html” (save this address as a “favorite” or “bookmark” so you won’t have to enter it each time you connect). 10. Follow the screen links to select the RE-1 items to program. 11. When fi nished programming, double-click on the dial-up networking icon in the status area of the task bar and select “Disconnect” to terminate the connection. ✦ NOTE: Be sure to disconnect when programming is completed.
operating system. For other types of computers and operating systems call Linear Technical Services for assistance. 1. A dial-up modem must be installed. 2. Dial-up networking must be installed. 3. An internet browser must be installed.
Creating a Local Computer Dial-up Connection 1. From “My Computer” select “Dial-up Networking” and select “Make New Connection”. 2. Name the connection “Local RE-1” and verify that the installed modem is listed as the device then select “Next”. 3. For the telephone number enter “###”, select “Next”, then select “Finish”. ✦ NOTE: The “###” prefi x to access programming is the default value for
the RE-1. It can be changed in the RE-1 using PPN #72. Be sure the prefi x entered as the telephone number matches what has been set in the RE-1 if it has been changed from the default. 4. Right-click on “Local RE-1” and select “Properties”. 5. From the “General” tab, in the “Connect Using” area, select “Confi gure...”. 6. From the “General” tab, in the “Speaker volume area”, set the volume to “High”. 7. Select the “Connection” tab. 8. Select “Advanced...” 9. In the “Use error control” area, de-select “Compress data” and select “OK” 10. Select “OK” again. 11. Select the “Server Types” or “Networking” tab. 12. In the “Advanced Options” area, de-select “Enable software compression”. 13. In the “Allowed network protocols” area, de-select “NetBEUI” and de-select “IPX/SPX Compatible”. Only “TCP/IP” should be selected. 14. Select “TCP/IP Settings...”. 15. Select “Specify an IP address”. 16. Enter “192.168.20.11” as the “IP address”. 17. De-select “Use IP header compression” and de-select “Use default gateway on remote network” then select “OK”. 18. Select “OK” again to complete the properties settings. Connecting Locally 1. Start your browser software. If your browser is set to automatically dial your normal Internet provider when the browser is opened, cancel the dialing when it starts. 2. Start “Dial-up networking”.














BE SURE ONLY THESE FIRST TWO BOXES ARE CHECKED

























REMOTE PROGRAMMING ACCESS
Remote Programming with a Telephone
Start with Step 1 below for local programming with the unit’s keypad or a local telephone. 1. Enter “###” (unless the programming prefi x has been changed) then the Master Programming Code (123456, unless it has been changed), then “#”. 2. Use the telephone keys or keypad to make any programming changes. Refer to the next section for details of the keystrokes for each programming PPN. The voice synthesizer will sound programming prompts. 3. To disconnect after programming, enter “99#”. ✦ NOTE: The RE-1 will automatically exit programming mode after fi ve
For remote programming, the RE-1 can be called from any TouchTone® telephone. Once the connection is made, the programming keystrokes are identical to what would be entered at the unit’s keypad or from a local telephone. Refer to the next section for details of the keystrokes for each programming PPN.
Remote Telephone Connection 1. Dial the telephone number of the line that the RE-1 is connected to. 2. Let the telephone ring twice and hang up. 3. After 10 seconds, but before 30 seconds, call back to the same telephone number. 4. The RE-1 will answer and sound a tone for 2 seconds. 5. The RE-1 will wait for approximately six seconds for the caller to enter the Master Programming Code. 6. Enter password (123456, unless it has been changed), then “#”. 7. Use the telephone keypad to make any programming changes. Refer to the next section for details of the keystrokes for each programming PPN. The voice synthesizer will sound programming prompts. 8. To disconnect after programming, enter “99#”.
minutes of no programming activity.

FACTORY DEFAULTS PPN 1 ENTRY CODE LENGTH 4 DIGITS PPN 8 TRANSMITTER LEFT (OR TOP LEFT) BUTTON ACTIVATES RELAY #1 TRANSMITTER RIGHT (OR TOP RIGHT) BUTTON ACTIVATES RELAY #2 TRANSMITTER TOP BUTTON ACTIVATES RELAYS #1 AND #2 TRANSMITTER LOWER LEFT BUTTON ACTIVATES NONE TRANSMITTER LOWER RIGHT BUTTON ACTIVATES NONE PPN 10 ENTRY TIME ZONES DISABLED PPN 12 HOLIDAYS NONE SET PPN 20 CLOCK & CALENDAR NOT SET PPN 21 RELAY #1 ON TIME 2 SECONDS PPN 22 RELAY #2 ON TIME 2 SECONDS PPN 23 MAIN KEYPAD ACTIVATES RELAY #1 OR #2 PPN 23 REMOTE KEYPAD ACTIVATES RELAY #2 PPN 24 RELAY #2 ALARM FUNCTION DISABLED PPN 26 MGT GATE EDGE TRANSMITTER DISABLED PPN 27 RELAY #2 ALTERNATE FUNCTION 2ND GATE OR DOOR PPN 28 REMOTE KEYPAD ADDRESS 3 PPN 29 SENSE INPUT ALTERNATE FUNCTION RELAY #1 SENSE RELAY #2 SENSE PPN 30 KEYPAD LOCKOUT COUNT 5 TRIES BEFORE LOCKOUT PPN 31 ANTI-PASSBACK TIME ANTI-PASSBACK DISABLED PPN 32 MAXIMUM NUMBER OF VISITOR RINGS 5 RINGS PPN 33 MODEM RING DETECT ON PPN 34 CALL FORWARDING DIALING METHOD TONE PPN 40 KEYPAD BEEPS ON PPN 41 RELAY #1 TONE OFF PPN 42 RELAY #2 TONE OFF PPN 43 RELAY TONE DURATION 1 SECOND PPN 44 VOICE SYNTHESIZER ON PPN 45 VISITOR TALK TIME LIMIT 60 SECONDS PPN 46 DAYLIGHT SAVING TIME AUTOMATIC ADJUSTMENT ON PPN 50 CALL WAITING FEATURE ON PPN 51 PRIVACY FEATURE OFF PPN 53 AUTOMATIC GATE/DOOR OPEN TIME NOT SET PPN 54 CALL FORWARDING FEATURE OFF PPN 55 ALTERNATE RESIDENT TELEPHONE NUMBERS ALL DISABLED PPN 71 RESIDENCE RESPONSE TELEPHONE KEYS 1 - ACTIVATE RELAY #1 2 - ACTIVATE RELAY #2 9 - DISCONNECT VISITOR 6 - SWITCH TO/FROM CALL WAITING PPN 72 RESIDENCE PROGRAMMING PREFIX ### PPN 72 RESIDENCE COMMAND PREFIX ## PPN 98 MASTER PROGRAMMING CODE 123456
PROGRAMMING CONTROL USAGE KEYSTROKES ENTER PROGRAMMING ###MASTER CODE# ESCAPE/CANCEL * EXIT PROGRAMMING 99#
PROGRAM POSITION NUMBERS (PPN) ENTRY CODE LENGTH PPN 1 PAGE 20 ADDING A NEW ENTRY CODE PPN 2 PAGE 20 REMOVING A SINGLE ENTRY CODE PPN 3 PAGE 20 ADDING TRANSMITTERS PPN 4 PAGE 21 SUSPEND OR ACTIVATE A SINGLE TRANSMITTER PPN 5 PAGE 21 ADDING A TEMPORARY ACCESS CODE PPN 6 PAGE 20 ASSIGNING TRANSMITTER BUTTONS TO RELAYS PPN 8 PAGE 21 SETTING THE TIME ZONES PPN 10 PAGE 20 SETTING THE HOLIDAY DAYS PPN 12 PAGE 20 SETTING THE CLOCK & CALENDAR PPN 20 PAGE 20 RELAY #1 ON TIME PPN 21 PAGE 22 RELAY #2 ON TIME PPN 22 PAGE 22 MAIN & REMOTE KEYPAD RELAY AND TIME ZONE PPN 23 PAGE 22 RELAY #2 ALARM FUNCTION PPN 24 PAGE 22 MGT GATE EDGE TRANSMITTER SETUP PPN 26 PAGE 22 RELAY #2 ALTERNATE OPTIONS PPN 27 PAGE 22 REMOTE KEYPAD ADDRESS PPN 28 PAGE 22 SENSE INPUT ALTERNATE FUNCTION PPN 29 PAGE 22 KEYPAD LOCKOUT COUNT PPN 30 PAGE 22 ANTI-PASSBACK TIME PPN 31 PAGE 22 MAXIMUM NUMBER OF VISITOR RINGS PPN 32 PAGE 21 MODEM RING DETECT ON/OFF PPN 33 PAGE 23 CALL FORWARDING DIALING METHOD PPN 34 PAGE 21 KEYPAD BEEPS ON/OFF PPN 40 PAGE 24 RELAY #1 TONE ON/OFF PPN 41 PAGE 24 RELAY #2 TONE ON/OFF PPN 42 PAGE 24 RELAY TONE DURATION PPN 43 PAGE 24 VOICE SYNTHESIZER ON/OFF PPN 44 PAGE 24 VISITOR TALK TIME LIMIT PPN 45 PAGE 21 DAYLIGHT SAVING TIME AUTOMATIC ADJUSTMENT ON/OFF PPN 46 PAGE 24 CALL WAITING ON/OFF PPN 50 PAGE 21 PRIVACY FEATURE SCHEDULE PPN 51 PAGE 21 INTERCOM MODE ON/OFF PPN 52 PAGE 21 AUTOMATIC DOOR/GATE OPEN TIME PPN 53 PAGE 24 CALL FORWARDING FEATURE PPN 54 PAGE 22 ALTERNATE RESIDENT TELEPHONE NUMBERS PPN 55 PAGE 22 RESIDENT RESPONSE TELEPHONE KEYS PPN 71 PAGE 22 RESIDENT PROGRAMMING & COMMAND PREFIXES PPN 72 PAGE 22 ERASING ALL TRANSMITTERS PPN 95 PAGE 21 ERASING ALL ENTRY CODES PPN 97 PAGE 20 CHANGING THE MASTER CODE PPN 98 PAGE 20 RESET SYSTEM DEFAULTS PPN 200 PAGE 22
for writing down other programming selections.
E D O C R E T S A M E D O C R E T S A M E D O C R E T S A M E D O C R E T S A M E D O C R E T S A M

ENTRY CODE PROGRAMMING
Setting the Entry Code Length Default: 4 digits Sets the number of digits for all the entry codes programmed.
The 6-digit Master Programming Code (default = 123456) is used to enter Programming Mode from a local or remote telephone or the keypad.
default of four digits, make this change fi rst, before programming any entry codes. Adding a New Entry Code
Use this PPN to add up to 100 entry codes.
minutes of programming inactivity.
Re-entering a Command After a Mistake
If an incorrect entry, or an incorrect key is pressed during programming, to clear the keypad:
Time Zone Code = The new entry code: 1-999999, depending on code length Relay = Relay that entry code will activate: 1 = Relay #1 2 = Relay #2 3 = Both Relays 4 = Latch Relay #1 (no access restrictions, latches relay, unlatch relay by re-entering code) Time Zone = 0 = no time zone; 1-7 to restrict access per time zone 1-7 If the new entry code chosen is already being used for another entry code, the system will reject the code. A new unique entry code needs to be entered.
Changing the Master Code
Use this PPN to change the six-digit Master Programming Code. Be sure to write down the new code.
Setting the Clock And Calendar
The time and date set in the clock and calendar control the system time zones, holiday schedules, and time stamping of the event log. The GTZ setting controls when the downlight is on. The RE-1 has an on-board lithium battery to maintain the date and time if power is removed from the unit.
✦ NOTE: Refer to PPN #23 for main and remote relay activation options.
Temporary entry codes with a starting and ending date can be created to permit limited access. Temporary entry codes will expire and no longer be able to grant access outside the programmed dates and a programmed number of uses. The total number of temporary and regular entry codes cannot exceed 100.
Year Hour Minute AM/PM GTZ Day of Week: 1 = Sun; 2 = Mon; 3 = Tue; 4 = Wed; 5 = Thu; 6 = Fri; 7 = Sat
Month = 1-12; Day = 1-31; Year = 2000-2127; Hour = 1-12 (in standard, non-daylight saving time)
Minute = 0-59; AM/PM: 0 = AM; 1 = PM GTZ (Geographic Time Zone): 0 = None (disables nightime keypad lighting);
Number Valid From Valid Thru Code = The new entry code: 1-999999, depending on code length Relay = Relay that entry code will activate: 1 = Relay #1 2 = Relay #2 3 = Both Relays Time Zone = 0 = no time zone; 1-7 to restrict access per time zone 1-7 Number = Number of times (1-255) that the entry code is allowed access Valid From = First date (MMDDYY) that the entry code is valid Valid Thru = Last date (MMDDYY) the entry code is valid. If the new temporary entry code chosen is already being used for another entry code, the system will reject the code. A new unique temporary entry code needs to be entered.
1 = Eastern; 2 = Central; 3 = Mountain; 4 = Pacifi c; 5 = Alaska; 6 = Hawaii
Seven time zones are available for restricting access, automatic gate entry, call forwarding schedule, assigning an access groups for transmitters, assigning a temporary entry code, and setting the “Do Not Disturb” schedule. A time zone constrained event will be allowed or occur between the start and end times on the active days selected.
✦ NOTE: Refer to PPN #23 for main and remote relay activation options.
Removing a Single Entry Code
Use this PPN to delete an entry code.
End Minute AM/PM Time Zone Number = 1-7 Active Days (Enter up to 8 digits): 1 = Sun; 2 = Mon; 3 = Tue; 4 = Wed; 5 = Thu; 6 = Fri; 7 = Sat; 8 = Holidays Start Hour = 1-12 Start Minute = 0-59 AM/PM: 0 = AM; 1 = PM End Hour = 1-12 End Minute = 0-59 AM/PM: 0 = AM; 1 = PM
Press: Code Code Code = The entry code to remove.
★ WARNING: This command will remove all entry codes.
Setting the Holiday Days
Up to ten holidays can be programmed. Holidays are used to restrict access on holiday days. If an entry method (code or transmitter) is assigned to a time zone, holidays must be set as an active day to allow access on holidays.

TELEPHONE PROGRAMMING
Maximum Number of Visitor Rings Default: 5 Rings Changes the maximum number of distinctive rings that the RE-1 will generate to the local telephones when the CALL button is pressed.
Up to 24 groups of transmitters can be assigned common access privileges sharing the same one or two time zones. Up to 100 transmitters total in all groups combined can be used in each RE-1 system.
Call Forwarding Dialing Method Default: Tone Sets the dialing method used during call forwarding to either tone or pulse style.
Time Zone 1 Time Zone 2 Number = Number of transmitters in the group Facility Code = Facility code 0-15 marked on block of transmitters; First ID = 5-digit ID number of fi rst transmitter in group. Time Zone 1 = 0 = no time zone; 1-7 to restrict access per time zone 1-7 Time Zone 2 = 0 = no time zone; 1-7 to restrict access per time zone 1-7
Visitor Talk Time Limit Default: 60 Seconds Sets the time that the visitor is allowed to talk to the resident. Ten seconds before the time expires, the voice synthesizer will announce “ten seconds”, and at fi ve seconds it will announce “fi ve seconds”, to the visitor. If the voice synthesizer is disabled (PPN #44), a beep will sound each second during the last ten seconds of time allowed.
✦ NOTE: If the Time Zone 1 entry is set to “0”, the Time Zone 2 entry is
ignored.
Each transmitter programmed can be individually suspended from use for access with this programming PPN. The transmitter will remain suspended until it is re-activated using this same programming PPN.
Press: Facility ID Action Facility = Facility code 0-15 of transmitter ID = 5-digit ID number of transmitter Action: 0 = Suspend transmitter; 1 = Re-activate transmitter
Call Waiting Feature On/Off Default: On Turns the call waiting feature on or off. If call waiting is on (factory default) and the resident is on the telephone at the same time a visitor calls, the RE-1 will generate beeps on the resident’s telephone line to signal that a visitor is calling. The resident has the option to switch to the visitor’s call. If the call waiting feature is off and the resident is on the telephone at the same time a visitor calls, the RE-1 will announce “resident busy” to the visitor.
transmitters from the memory.
Assigning Transmitter Buttons to Relays Defaults: Left (or Top Left) = Relay #1 Right (or Top Right) = Relay #2 Top Button = Both Relays Lower Left = None Lower Right = None The RE-1 can be programmed to control which relay will activate from which transmitter button. This setting will effect all transmitters (single and multi-channel) used with the RE-1
Privacy Feature Schedule Default: Off The privacy feature will block visitor’s calls and call forwarding during the selected Time Zone or at all times. If the privacy feature is active and a visitor calls, the RE-1 will announce “do not disturb resident”. If call forwarding is scheduled (PPN #54) and the privacy feature is active, the RE-1 will announce “do not disturb resident” and visitor’s call will not be forwarded.
Press: Privacy Time Zone Privacy: 0 = Privacy feature OFF 1 = Privacy feature ON (scheduled by Time Zone) 2 = Privacy feature ON at all times Time Zone = 1-7 (Privacy feature active during this Time Zone)
Press: Button Relay Button: 1 = Right (or Top Right); 2 = Left (or Top Left) 4 = Top; 5 = Bottom Right; 6 = Bottom Left Relay: 0 = None; 1 = Relay #1; 2 = Relay #2; 3 = Both Relays
Intercom Mode On/Off Default : Off The RE-1 includes an Intercom Mode that allows the unit to be operated independent of the Public Switched Network. In this mode, the RE-1 directly supplies the power for the house telephone(s) connected to it. To use the RE-1 in intercom mode, connect the telephone line as shown under Telephone Wiring Options on Page 6. Note that the RE-1’s Telephone Bypass Module is included in the circuit for additional telephone line surge protection. Be sure the Telephone Bypass Module’s switch is in the NORMAL position.
RIGHT BUTTON
AS LEFT BUTTON
LEFT BUTTON BOTTOM-LEFT
LEFT BUTTON
BUTTON
BOTTOM-RIGHT
ACT-31
BUTTON
ACT-34
SINGLE-CHANNEL
TRANSMITTERS
ACT-21
FOUR-CHANNEL
TRANSMITTER
Network, the call forwarding and alternate resident telephone dialing features will not be available. This programming step turns the intercom mode on or off. If intercom mode is on, the RE-1 will power the house telephone(s). If intercom mode is off, the Telephone Company will power the house telephone(s).
TOP BUTTON
BOTH EQUALS
RIGHT BUTTON
TOP BUTTON
RIGHT BUTTON
LEFT BUTTON
LEFT BUTTON
RIGHT BUTTON
BOTTOM-RIGHT
LEFT BUTTON
BUTTON BOTTOM-LEFT
BUTTON
Press Intercom Mode
ACT-22
MDT-4
THREE-CHANNEL
FIVE-CHANNEL
TRANSMITTER
TRANSMITTERS

Call Forwarding Feature Default: OFF The call forwarding feature will allow a visitor to contact the resident at the programmed telephone number instead of through the local telephone line. The feature can be set to be active during a selected Time Zone or at all times. The telephone number programmed can contain an extension number and an optional time delay before dialing the extension.
Resident Response Telephone Keys Defaults: Key A “1” = Activates Relay #1 Key B “2” = Activates Relay #2 Key C “9” = Disconnect Visitor’s Call Key D “6” = Switch To/From Call Waiting The resident response keys are the telephone keys that the resident uses to grant access and control calls from a visitor. The keys for the four functions can be customized. Enter all four keys each time this programming PPN is used.
Telephone Number Extension Delay Forwarding: 0 = Call forwarding feature OFF 1 = Call forwarding feature ON at all times 2 = Call forwarding feature ON (scheduled by Time Zone) 3 = Forward the call if there was no resident answer Time Zone = 1-7 (Call forwarding feature active during this Time Zone) Telephone Number = Up to 11-digit telephone number Extension = Up to 4-digit telephone extension number Delay = 1-25 seconds (delay between telephone number and extension)
Press: Keys ABCD Keys ABCD: Enter 4 digits for the response keys A, B, C, & D Key A = Activates Relay #1 Key B = Activates Relay #2 Key C = Disconnects the Visitor’s Call Key D = Switches to and from a call holding on call waiting
Command = “##” The resident command prefi x is entered on a local telephone prior to entering a command number to control one of the relays or open voice communications with the RE-1. The resident programming prefi x is entered on a local telephone or the main keypad prior to programming the RE-1.
Example, call forwarding with only a phone number:
A special feature is implemented for “Ring Down” PBX systems. If no telephone number is programmed and call forwarding is enabled, the unit will connect immediately without dialing.
Press: Programming Command Programming: 0 = “###”; 1 = “***”; 2 = “*#*”; 3 = “#*#” Command: 0 = “##”; 1 = “**”; 2 = “*#”; 3 = “#*” ADVANCED SYSTEM PROGRAMMING
Example, call forwarding with extension and no time zone:
Reset System Defaults
Extension Delay
The system can be reset back to the factory defaults with this programming PPN. EXECUTING THIS PPN WILL NOT ERASE ANY ENTRY CODES OR TRANSMITTERS THAT HAVE BEEN PROGRAMMED.
Example, call forwarding scheduled by time zone:
Press: Relay #1 On Time Default 2: Seconds Changes the length of time Relay #1 activates when triggered.
Example, call forwarding off:
Relay #2 On Time Default: 2 Seconds Changes the length of time Relay #2 activates when triggered.
Alternate Resident Telephone Numbers Default: All Disabled For installations where multiple residences exist behind shared controlled access, the RE-1 can dial three alternate telephone numbers. The visitor can call an alternate number by entering “1#”, “2#”, or “3#” on the main keypad.
Main & Remote Keypad Relay and Time Zone Default: Main Keypad = Set by Entry Code, No Time Zone Remote Keypad = Relay #2, No Time Zone Sets the relay and time zone that the main and remote keypad will use.
Press: Keypad Relay Time Zone Keypad: 1 = Main Keypad 2 = Remote Keypad (Also see PPN #28) Relay: 1 = Relay #1 2 = Relay #2 3 = Set by entry code Time Zone: 0 = no time zone 1-7 to restrict access per time zone 1-7
Telephone Number Extension Delay Location: 1 = “1#” location; 2 = “2#” location; 3 = “3#” location Enable: 0 = Disable; 1 = Unconditionally enable Telephone Number: Up to 11-digit telephone number Extension: Up to 4-digit telephone extension number Delay: 1-25 seconds (delay between telephone number and extension)
option should be set to “3”.

Relay #2 Alternate Options Default: Access Relay Relay #2 can be used for functions other than triggering a gate operator or door strike. Relay #2 can be programmed to shunt alarm contacts during Relay #1 activation or perform up to fi ve Alarm Functions. Two PPN numbers are used to program the Relay #2 options.
Sense Input Alternate Function Defaults: SENSE #1 = SENSE SENSE #2 = SENSE Each of the two SENSE inputs can be independently programmed to act as INHIBIT inputs. As an INHIBIT input, as long as the input is grounded, access can not be granted for that input’s relay (1 or 2). A typical application would be connection of an external timer or service switch to temporarily prevent visitors from activating the access device.
Press: Role Role: 0 = Access Relay 1 = Alarm Shunt (Follows Relay #1 activation, used to shunt external alarm contacts with Relay #2’s contacts) 2 = Obstacle Detector 3 = Activate during one or more of the fi ve Alarm Functions programmed below
Press: Input Type Input: 1 = SENSE #1 2 = SENSE #2 Type: 0 = Input will perform as SENSE 1 = Input will perform as INHIBIT
✦ NOTE: More than one alarm function can be enabled at a time. Up to fi ve
digits can be entered for “Activate”.
Keypad Lockout Count Default: 5 Tries The Keypad Lockout Count sets the number of incorrect code entry attempts required to place the keypad in “lockout” for a one minute period. During “lockout” the keypad will not accept any code entries. The Keypad Lockout Count effects both the main and remote keypads.
Press: Activate Activate: 0 = No alarm function (default) 1 = On forced entry (activates when SENSE #1 input opens without Relay #1 activation) 2 = On door/gate ajar (activates when SENSE #1 input stays open for longer than one minute after Relay #1 activation) 3 = On main keypad lockout (activates when the main keypad is in “lockout” from too many incorrect code attempts) 4 = On remote keypad lockout (activates when the remote keypad is in “lockout” from too many incorrect code attempts) 5 = On driveway sensor (activates when SENSE #2 input closes)
Anti-passback Time Default: Off The Anti-passback feature prevents the same entry code or transmitter from being used to gain access more than once during the set time.
Linear’s Model MGT Gate Edge Transmitter can be used with the RE-1 for obstacle detection. When the gate edge sensor triggers the MGT transmitter, the RE-1 can be programmed to activate Relay #2 which would in turn, activate the obstacle input of the gate operator.
Modem Ring Detect On/Off Default: On The RE-1’s built-in modem monitors the telephone line for telephone rings. When the Modem Ring Detect is enabled, the modem will answer the telephone if two consecutive telephone calls occur within 30 seconds. The Modem Ring Detect can be disabled, this will also disable any computer based programming of the RE-1.
Press: Obstacle Facility ID Obstacle: 0 = No MGT obstacle transmitter (default) 1 = MGT obstacle transmitter used Facility: Facility code 0-15 of MGT transmitter ID = 5-digit ID number of transmitter
“0”.
Remote Keypad Address Default: 3 If a Linear Model AM-KP is used as a remote keypad the ADDRESS switch in the remote keypad needs to match the “address” setting in the RE-1. For most installations, simply set the remote keypad’s ADDRESS switch to “3” to match the RE-1 default setting. If required, use the following programming PPN to change the address number.
RESTART button.

Keypad Beeps On/Off Default: On The default setting causes the main keypad to beep when each key is pressed. The beeps can be disabled.
The RE-1 Entry System audio levels can be adjusted to suit the installation requirements. If required, make these adjustments after programming, but before closing and securing the RE-1 case.
The SPEAKERPHONE VOLUME adjustment controls the audio level that the RE-1 speaker produces during communications between the visitor and the resident.
Relay #1 Tone On/Off Default: Off The default setting does not cause the annunciator to sound when Relay #1 is activated. The Relay #1 activation tone can be enabled.
to cut-out as the system switches from talk to listen. 1. Have someone waiting to receive the call. Push the CALL button to call the residence. 2. Have the resident talk at a normal volume level while adjusting the SPEAKERPHONE VOLUME control. Adjusting the control clockwise increases the volume, counterclockwise decreases the volume.
Relay #2 Tone On/Off Default: Off The default setting does not cause the annunciator to sound when Relay #2 is activated. The Relay #2 activation tone can be enabled.
The DIGITAL SPEECH VOLUME adjustment controls the audio level of the voice synthesizer. This adjustment effects the audio level of the voice synthesizer from the speaker and through the telephone. 1. Push the HELP button to cause the voice synthesizer to sound the help message. 2. Adjust the DIGITAL SPEECH VOLUME to suit the installation. Adjusting the control clockwise increases the volume, counterclockwise decreases the volume.
Relay Tone Duration Default: 1 Second The default setting causes the annunciator to sound for 1 second when Relay #1 or Relay #2 is activated (if the tones are enabled). The length of the activation annunciation can be changed.
Voice Synthesizer On/Off Default: On When the voice synthesizer is on the RE-1 will sound voice prompts during operation and programming. If the voice synthesizer is off, the system will sound beeps to indicate conditions. The HELP button will announce “Enter code or press call button to contact resident” regardless of this setting. The beeps produced when the voice synthesizer is off are:
Automatic Daylight Saving Time Clock Adjustment On/Off Default: On The RE-1’s internal clock used for controlling system functions and time stamping of the event log automatically adjusts for daylight saving time. The time will change on the fi rst Sunday in April, and on the last Sunday of October. For areas where daylight saving time is not observed, this feature may be disabled.
Press: Daylight Saving Daylight Saving: 0 = Daylight Saving Adjust OFF 1 = Daylight Saving Adjust ON
Automatic Door/Gate Open Time Default: Not Set Each control relay can be programmed for automatic activation. One or two Time Zones can be assigned to a relay. The relay will activate and remain latched during the active period of the Time Zone.
Press: Relay 1st Time Zone 2nd Time Zone Relay: 1 = Relay #1 2 = Relay #2 1st Time Zone = Time Zone 1-7 2nd Time Zone = Time Zone 1-7 (enter “0” if the 2nd time zone is not used)

(see PPN #72).
pressing on the telephone.
Relay #1 by pressing , or activating Relay #2 by pressing .
pressing or by hanging up.
changed (see PPN #71).
, , or . The three numbers are defi ned by programming.

Some of the programming PPN’s may be commonly used by the resident. Following are quick references to the keystrokes required.
Rings = 1-15 Rings maximum
assumes that the default has not been changed.
Press: Limit
To Enter Programming Mode
Limit = 15-255 Seconds allowed
Master Code = the current 6-digit Master Programming Code
Press: Call Waiting
To Exit Programming Mode & Save Changes
Call Forwarding
Re-entering a Command After a Mistake
Press: Forwarding Time Zone Telephone Number
If an incorrect entry, or an incorrect key is pressed during programming, to clear the keypad:
Forwarding: 0 = Call forwarding feature OFF 1 = Call forwarding feature ON at all times 2 = Call forwarding feature ON (scheduled by Time Zone) Time Zone = 1-7 (Call forwarding feature active during this Time Zone) Telephone Number = Up to 11-digit telephone number Extension = Up to 4-digit telephone extension number Delay = 1-25 seconds (delay between telephone number and extension) Example: Press: Telephone Number
Adding a Entry Code
Press: Code Code Relay Time Zone
Code = The new entry code: 1-999999, depending on code length Relay = Relay output entry code will activate: 1 = Relay #1 2 = Relay #2 3 = Both Relays 4 = Relay #1 as priority user (no access restrictions) Time Zone = 0 = no time zone; 1-7 to restrict access per time zone 1-7
Press: Privacy Time Zone
Privacy: 0 = Privacy feature OFF 1 = Privacy feature ON (scheduled by Time Zone) 2 = Privacy feature ON at all times Time Zone = 1-7 (Privacy feature active during this Time Zone)
Press: Code Code Relay Time Zone Number
Valid From Valid Thru
Code = The new entry code: 1-999999, depending on code length Relay = Relay output entry code will activate: 1 = Relay #1 2 = Relay #2 3 = Both Relays Time Zone = 0 = no time zone; 1-7 to restrict access per time zone 1-7 Number = Number of times (1-255) that the entry code is allowed access Valid From = First date (MMDDYY) that the entry code is valid Valid Thru = Last date (MMDDYY) the entry code is valid.
Press: Relay 1st Time Zone 2nd Time Zone
Relay: 1 = Relay #1 2 = Relay #2 1st Time Zone = Time Zone 1-7 2nd Time Zone = Time Zone 1-7 (enter “0” if the 2nd time zone is not used)
Setting Time Zones
Press: Code Code
Press: Time Zone Number Active Days Start Hour
Code = The entry code to remove.
Start Minute AM/PM End Hour End Minute AM/PM Time Zone Number = 1-7 Active Days (Enter up to 8 digits): 1 = Sun; 2 = Mon; 3 = Tue; 4 = Wed; 5 = Thu; 6 = Fri; 7 = Sat; 8 = Holidays Start Hour = 1-12 Start Minute = 0-59 AM/PM: 0 = AM; 1 = PM End Hour = 1-12 End Minute = 0-59 AM/PM: 0 = AM; 1 = PM
Press: Facility ID Action
Facility = Facility code 1-16 of transmitter (0 = no facility code) ID = 5-digit ID number of transmitter Action: 0 = Suspend transmitter; 1 = Re-activate transmitter
Press: Holiday Number Month Day
Holiday Number = 1-10 Month = 1-12 Day = 1-31

TROUBLESHOOTING
MECHANICAL Case dimensions: 6.45” W x 10.81” H x 3.74” D ELECTRICAL Voltage: 16 Volts AC or 12-24 Volts DC Current: 650 mA AC typical, 1300 mA AC maximum Backup Battery: Externally charged 12-24 Volt DC source Backup Battery Current: with 12-volt backup battery 250 mA standby 600 mA ringing one phone 1100 mA maximum with 24-volt backup battery 200 mA standby 350 mA ringing one phone 600 mA maximum Outputs: Relay #1 Form “C” 3 Amps @ 30 Volts maximum Relay #2 Form “C” 3 Amps @ 30 Volts maximum Inputs: Two normally closed door sense/inhibit inputs Two normally open request to exit inputs RADIO Frequency: 318 Mhz ± 500 KHz @ 23°C RF 3db Bandwidth: 4 MHz Typical Sensitivity: -97 dBm Minimum (-100 dBm Typical) Encoding: Linear MegaCode® Format ENVIRONMENTAL Temperature: -22°F to 149°F (-30°C to 65°C) Humidity: 5% to 95% non-condensing DIMENSION DRAWING
6.45" 3.74"
10.81"
times”, no programming entry is needed for the time zone (see example in PPN #54).
5.95"
3.39"
Relay #1 will not latch from the keypad
2.75"
1.30" DIA.
2.75"

S E N O Z E M I T S E N O Z E M I T S E N O Z E M I T S E N O Z E M I T S E N O Z E M I T
S Y A D E VIT C A S Y A D E VIT C A S Y A D E VIT C A S Y A D E VIT C A S Y A D E VIT C A E M IT T R A T S E M IT T R A T S E M IT T R A T S E M IT T R A T S E M IT T R A T S E M IT D N E E M IT D N E E M IT D N E E M IT D N E E M IT D N E
E N O Z E N O Z E N O Z E N O Z E N O Z N U S N U S N U S N U S N U S N O M N O M N O M N O M N O M E U T E U T E U T E U T E U T D E W D E W D E W D E W D E W U H T U H T U H T U H T U H T I R F I R F I R F I R F I R F T A S T A S T A S T A S T A S S Y A D IL O H S Y A D IL O H S Y A D IL O H S Y A D IL O H S Y A D IL O H R U O H R U O H R U O H R U O H R U O H E T U N I M E T U N I M E T U N I M E T U N I M E T U N I M M P/ M A M P/ M A M P/ M A M P/ M A M P/ M A R U O H R U O H R U O H R U O H R U O H E T U N I M E T U N I M E T U N I M E T U N I M E T U N I M M P/ M A M P/ M A M P/ M A M P/ M A M P/ M A
E M IT E M IT E M IT E M IT E M IT

S Y A D I L O H S Y A D I L O H S Y A D I L O H S Y A D I L O H S Y A D I L O H

Y A D IL O H Y A D IL O H Y A D IL O H Y A D IL O H Y A D IL O H E M A N E M A N E M A N E M A N E M A N H T N O M H T N O M H T N O M H T N O M H T N O M Y A D Y A D Y A D Y A D Y A D
E D O C R E T S A M E D O C R E T S A M E D O C R E T S A M E D O C R E T S A M E D O C R E T S A M
R E B M U N G N I D R A W R O F L L A C R E B M U N G N I D R A W R O F L L A C R E B M U N G N I D R A W R O F L L A C R E B M U N G N I D R A W R O F L L A C R E B M U N G N I D R A W R O F L L A C
1 R E B M U N E N O H P E L E T E T A N R E T L A 1 R E B M U N E N O H P E L E T E T A N R E T L A 1 R E B M U N E N O H P E L E T E T A N R E T L A 1 R E B M U N E N O H P E L E T E T A N R E T L A 1 R E B M U N E N O H P E L E T E T A N R E T L A
RESIDENT RESPONSE TELEPHONE KEY FOR RELAY #1 71 1
RESIDENT RESPONSE TELEPHONE KEY FOR RELAY #2 71 2
2 R E B M U N E N O H P E L E T E T A N R E T L A 2 R E B M U N E N O H P E L E T E T A N R E T L A 2 R E B M U N E N O H P E L E T E T A N R E T L A 2 R E B M U N E N O H P E L E T E T A N R E T L A 2 R E B M U N E N O H P E L E T E T A N R E T L A
RESIDENT RESPONSE TELEPHONE KEY FOR VISITOR DISCONNECT 71 9
RESIDENT RESPONSE TELEPHONE KEY FOR SWITCH TO/FROM CALL WAITING 71 6
3 R E B M U N E N O H P E L E T E T A N R E T L A 3 R E B M U N E N O H P E L E T E T A N R E T L A 3 R E B M U N E N O H P E L E T E T A N R E T L A 3 R E B M U N E N O H P E L E T E T A N R E T L A 3 R E B M U N E N O H P E L E T E T A N R E T L A

E D O C Y R T N E E D O C Y R T N E E D O C Y R T N E E D O C Y R T N E E D O C Y R T N E # Y A L E R # Y A L E R # Y A L E R # Y A L E R # Y A L E R E N O Z E M IT E N O Z E M IT E N O Z E M IT E N O Z E M IT E N O Z E M IT E D O C Y R T N E E D O C Y R T N E E D O C Y R T N E E D O C Y R T N E E D O C Y R T N E # Y A L E R # Y A L E R # Y A L E R # Y A L E R # Y A L E R E N O Z E M IT E N O Z E M IT E N O Z E M IT E N O Z E M IT E N O Z E M IT
R E S U R E T TI M S N A R T R E S U R E T TI M S N A R T R E S U R E T TI M S N A R T R E S U R E T TI M S N A R T R E S U R E T TI M S N A R T Y TILI C A F Y TILI C A F Y TILI C A F Y TILI C A F Y TILI C A F
E D O C E D O C E D O C E D O C E D O C E D O C D I E D O C D I E D O C D I E D O C D I E D O C D I E N O Z E M IT T S 1 E N O Z E M IT T S 1 E N O Z E M IT T S 1 E N O Z E M IT T S 1 E N O Z E M IT T S 1 E N O Z E M IT D N 2 E N O Z E M IT D N 2 E N O Z E M IT D N 2 E N O Z E M IT D N 2 E N O Z E M IT D N 2 P U O R G X T P U O R G X T P U O R G X T P U O R G X T P U O R G X T
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _
2 _ _ 1 _ _ 2 _ _ 1 _ _

Changes or modifi cations not expressly described in this manual or approved by the manufacturer could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
This Linear product is warranted against defects in material and workmanship for twenty-four (24) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until Warranty Expiration Date as labeled on the product. This Linear LLC Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
Linear radio controls provide a reliable communications link and fi ll an important need in portable wireless signaling. However, there are some limitations which must be observed.
Copyright © 2008 Linear LLC 217490 C
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.