RE-1p.1Residential Telephone Entry Systemp.1With Built-in Wireless Receiverp.1Installation, Programming, and Operation Instructionsp.1(760) 438-7000 USA & Canada (800) 421-1587 & (800) 392-0123p.1Toll Free FAX (800) 468-1340p.1www.linearcorp.comp.1CONTENTS FEATURESp.2RESIDENT PROGRAMMING QUICK REFERENCE . . . . . . 26p.2PRODUCT DESCRIPTIONp.3System Featuresp.3Operationp.3Access Mediap.3INSTALLATION INFORMATIONp.4Telephone Wiresp.4System Locationp.4Power Supplyp.4★ WARNING FOR ALL GATE INSTALLATIONS: TO AVOIDp.4RFI Filter Installationp.4Earth Groundp.4Removable Terminal Stripsp.4RFI FILTER INSTALLED WITHIN 2" OF RE-1 CASEp.4PULL ON PLASTIC TAB TO UNLOCK FILTER CASEp.4SWING FILTER CASE OPENp.4PHONE AND TRANSFORMER WIRES OUTSIDE OF FILTERp.4FERRITE COREp.4COMPONENT LOCATIONSp.5WIRING DIAGRAMp.6STAKEp.6ENTRY SYSTEM MOUNTINGp.7TELEPHONE WIRINGp.7Pedestal Mountingp.7Telephone Bypass Modulep.7Wall Mountingp.7Typical Telephone Wiringp.7TELEPHONEp.7BYPASS MODULEp.7EARTHp.7RE-1 ENTRY SYSTEMp.7TIPp.7TELCOp.7RINGp.7CASE GROUNDp.7HOUSEp.7CASE GROUND SCREWp.7TO HOUSEp.7PHONESp.7RE-1 HOUSEp.7RE-1 TELCOp.7GROUNDp.7TO TELCOp.7LINEp.7TELEPHONE WIRING OPTIONSp.8Intercom Modep.8Shared Linep.8TO HOUSE INTERCOM TELEPHONESp.8STAKE TIPp.8FROM TELEPHONEp.8COMPANYp.810' MAXIMUM WIRE RUNp.8Dedicated Linep.8Ring Down Modep.8TO PBX SYSTEMp.8EARTH GROUND FROM TELEPHONEp.8CONTROL WIRINGp.10Door or Pedestrian Gate Controlp.10Gate Controlp.10GATE OPERATOR (BEHIND GATE)p.102 WIRES FOR DOOR SENSE SWITCHp.104 WIRES FOR TELEPHONEp.10DOOR SENSE SWITCHp.10ELECTRIC DOOR STRIKEp.102 WIRES FOR RE-1 POWER FROM TRANSFORMERp.102 WIRES FOR DOOR STRIKEp.10NOTE: ROUTE TELEPHONE WIRES AWAY FROM POWER WIRESp.102 WIRES FROM RE-1 TO GATE OPEN TERMINALSp.102 WIRES FROM TRANSFORMER FOR RE-1 POWERp.10RELAYp.10COMp.10GATE OPERATOR OPENp.10
Page 1 of the Linear Telephone Entry System (RE-1) user manual — (760) 438-7000 USA & Canada (800) 421-1587 & (800) 392-0123
Page 1 · click to enlarge
Page 1

RE-1

Residential Telephone Entry System

Linear Telephone Entry System (RE-1) — RE-1 diagram (page 1)
Fig. 1

With Built-in Wireless Receiver

Installation, Programming, and Operation Instructions

(760) 438-7000 USA & Canada (800) 421-1587 & (800) 392-0123

Toll Free FAX (800) 468-1340

www.linearcorp.com

Page 2 of the Linear Telephone Entry System (RE-1) user manual — Table of Contents
Page 2 · Contents
Contents

Contents

RE-1p.1Residential Telephone Entry Systemp.1With Built-in Wireless Receiverp.1Installation, Programming, and Operation Instructionsp.1(760) 438-7000 USA & Canada (800) 421-1587 & (800) 392-0123p.1Toll Free FAX (800) 468-1340p.1www.linearcorp.comp.1CONTENTS FEATURESp.2RESIDENT PROGRAMMING QUICK REFERENCE . . . . . . 26p.2PRODUCT DESCRIPTIONp.3System Featuresp.3Operationp.3Access Mediap.3INSTALLATION INFORMATIONp.4Telephone Wiresp.4System Locationp.4Power Supplyp.4★ WARNING FOR ALL GATE INSTALLATIONS: TO AVOIDp.4RFI Filter Installationp.4Earth Groundp.4Removable Terminal Stripsp.4RFI FILTER INSTALLED WITHIN 2" OF RE-1 CASEp.4PULL ON PLASTIC TAB TO UNLOCK FILTER CASEp.4SWING FILTER CASE OPENp.4PHONE AND TRANSFORMER WIRES OUTSIDE OF FILTERp.4FERRITE COREp.4COMPONENT LOCATIONSp.5WIRING DIAGRAMp.6STAKEp.6ENTRY SYSTEM MOUNTINGp.7TELEPHONE WIRINGp.7Pedestal Mountingp.7Telephone Bypass Modulep.7Wall Mountingp.7Typical Telephone Wiringp.7TELEPHONEp.7BYPASS MODULEp.7EARTHp.7RE-1 ENTRY SYSTEMp.7TIPp.7TELCOp.7RINGp.7CASE GROUNDp.7HOUSEp.7CASE GROUND SCREWp.7TO HOUSEp.7PHONESp.7RE-1 HOUSEp.7RE-1 TELCOp.7GROUNDp.7TO TELCOp.7LINEp.7TELEPHONE WIRING OPTIONSp.8Intercom Modep.8Shared Linep.8TO HOUSE INTERCOM TELEPHONESp.8STAKE TIPp.8FROM TELEPHONEp.8COMPANYp.810' MAXIMUM WIRE RUNp.8Dedicated Linep.8Ring Down Modep.8TO PBX SYSTEMp.8EARTH GROUND FROM TELEPHONEp.8CONTROL WIRINGp.10Door or Pedestrian Gate Controlp.10Gate Controlp.10GATE OPERATOR (BEHIND GATE)p.102 WIRES FOR DOOR SENSE SWITCHp.104 WIRES FOR TELEPHONEp.10DOOR SENSE SWITCHp.10ELECTRIC DOOR STRIKEp.102 WIRES FOR RE-1 POWER FROM TRANSFORMERp.102 WIRES FOR DOOR STRIKEp.10NOTE: ROUTE TELEPHONE WIRES AWAY FROM POWER WIRESp.102 WIRES FROM RE-1 TO GATE OPEN TERMINALSp.102 WIRES FROM TRANSFORMER FOR RE-1 POWERp.10RELAYp.10COMp.10GATE OPERATOR OPENp.10
Page 3 of the Linear Telephone Entry System (RE-1) user manual — Access Media
Page 3 · click to enlarge
Page 3

PRODUCT DESCRIPTION

System Features

Time Zones The RE-1 contains an internal clock and calendar. Seven programmable “time zones” allow setting time periods to schedule system functions. Each time zone can be active or inactive on certain days. Keypad entry codes, wireless transmitters, automatic access control, call forwarding, and the “Do Not Disturb” feature can each be set to only be active during a specifi c time zone period. Up to ten “holiday” days can be programmed. Each of the seven time zones can be set to be active or inactive during a holiday.

Linear’s RE-1 Telephone Entry System is designed for residential or light commercial access control applications. The speakerphone, keypad, radio receiver, and optional video camera are housed in a rugged enclosure that can be mounted to a pedestal or bolted directly to a wall. The die-cast keypad keys have bright, easy-to- read graphics and are lit with an overhead light. The two operation buttons; CALL and HELP, are machined for heavy-duty reliability.

Operation

Arriving visitors will approach the unit and place a call to the residence by pressing the CALL button. The RE-1 will acquire the residence’s local telephone line and generate distinctive rings to the house telephones. The resident, knowing that the distinctive ring is originating from the access area, can answer any house telephone and converse with the visitor. If the resident decides to grant access to the visitor, they can activate either output relay in the RE-1 by pressing a key on the telephone’s keypad. If the resident decides not to grant access, hanging up or pressing a key will disconnect the visitor’s call.

Portal Supervision The SENSE/INHIBIT input can be used two ways. If programmed for “door sense”, a switch on the door detects forced entry or door ajar situations. If programmed for “inhibit”, the input can be wired to a “service” switch or automatic timer that will disable the Relay #1 when required.

Hardwired Activation The OPEN REQUEST input can be wired to an exit loop detector or exit photo beam to allow automatic exit activation. An emergency access keyswitch can be mounted in the RE-1 case to allow keyed entry for authorized personnel.

Call Waiting If the resident is using the telephone at the time a visitor calls, the RE-1 will sound beeps on the telephone line to announce that a visitor is calling. The resident can press a key on the telephone to place the outside caller on hold and communicate with the visitor. After granting or denying access to the visitor, the outside caller will be re-connected to the resident.

Access Security The “anti-passback” feature allows the option of preventing the use of the same code or the same transmitter again before the programmed time elapses. The “keypad lockout” feature discourages tampering by disabling the keypad for one minute after a programmable number of incorrect entry codes has been entered at the keypad.

Call Forwarding Programmable call forwarding allows the RE-1 to dial any selected telephone number when a visitor presses the CALL button. For example, with call forwarding enabled, the RE-1 could dial a cell phone to contact the resident while outside or away from the residence. The resident will be able to communicate with the visitor and grant or deny access from the remote telephone.

Event Log An access log of up to 450 events is stored in the unit’s memory. System activity is logged as it occurs with the date and time of the event. The access log data can be retrieved locally or remotely with a computer through the RE-1’s built-in modem.

Local & Remote Programming The system’s built-in programming software can be accessed on-site or off-site using a computer with any Internet browser. The software’s graphic display of each of the programming steps make programming easy. Without a computer, the RE-1 can be programmed with its main keypad, from any local telephone connected to the same line, or by calling from any remote telephone. The EEPROM memory retains all entry codes, transmitter information, and programming, even without power.

Alternate Numbers For installations where multiple residences exist inside the same controlled opening (such as a guest house or granny fl at) three alternate calling numbers can be programmed. The alternate numbers can be called by entering a short code at the keypad.

Local Control The resident can issue control commands from the local telephones without a call from a visitor. By dialing a specifi c series of digits, the resident can control either of the two relays. The resident can also initiate voice communications with the entry system.

Obstacle Detection Linear’s Model MGT safety edge transmitter is compatible with the RE-1 This MGT detects and transmits obstacle events to the RE-1 receiver. Obstacle signals from an MGT transmitter will activate Relay #2.

Access Media

Up to 100 entry codes, from 1 to 6 digits in length, can be programmed. Each entry code can activate either, or both, of the relay outputs. Linear’s Model AM-KP keypad can be used as a secondary remote keypad for the RE-1. Up to 24 sets of block coded MegaCode® transmitters (up to 100 transmitters total) can be used to gain access through the RE-1’s built-in radio receiver. Each transmitter can be individually suspended or re-activated. One facility code can be programmed to identify each block of transmitters. Programming of individual (non-block coded) transmitters is not supported by the RE-1.

Alarm Interface Relay #2 can be programmed for alarm shunt to bypass an alarm loop during entry, or alarm trigger to cause an alarm during forced entry. Four activation options are available for Relay #2.

Voice Synthesizer A built-in voice synthesizer sounds voice prompts through the speaker, local and remote telephones.

Page 4 of the Linear Telephone Entry System (RE-1) user manual — PHONE AND TRANSFORMER WIRES OUTSIDE OF FILTER
Page 4 · click to enlarge
Page 4

INSTALLATION INFORMATION

Telephone Wires

The quality of the system’s audio communications is related to the type of telephone wire and its installation. Noise and hum can be introduced into the telephone wires. Use only high-quality telephone wire rated for direct underground burial. All telephone wire should be twisted-pair.

Before beginning installation, please review the entire instructions and become familiar with the system’s operation, wiring, and programmable options.

System Location

For pedestrian door or gate installations, mount the Entry System on a rigid wall near the controlled door. Avoid mounting the unit in a location where regular mechanical shock will occur due to a slamming door or spring loaded pedestrian gate. For vehicular gate installations, mount the Entry System in clear view of the gate, but far enough from the gate so the user cannot touch the gate from the keypad.

  • Minimum size of 24 AWG for up to 800 feet.
  • Minimum size of 22 AWG for up to 1600 feet.
  • Minimum size of 20 AWG for up to 2200 feet.
  • Minimum size of 18 AWG for up to 3600 feet. DO NOT ROUTE TELEPHONE AND AC WIRING INSIDE THE SAME CONDUIT . Route all telephone wires inside a dedicated conduit that is at least six inches away from any AC line wiring.

Power Supply

Use the supplied 16-volt 20-VA transformer to power the RE-1. DO NOT POWER ANY OTHER EQUIPMENT FROM THE SAME TRANSFORMER, use a separate power supply. Keep the system power wires as short as practical to reduce the chance of noise and hum pickup.

★ WARNING FOR ALL GATE INSTALLATIONS: TO AVOID

SERIOUS INJURY OR DEATH, MAKE SURE THAT THE UNIT IS FAR ENOUGH FROM THE GATE SO THAT THE USER CANNOT TOUCH THE GATE WHILE OPERATING THE KEYPAD. HOWEVER, FOR SAFETY, THE GATE MUST BE FULLY VISIBLE FROM THE KEYPAD.

  • For low voltage power wire runs up to 100 feet, use 18 AWG, THHN 600-volt insulated wire.
  • For low voltage power wire runs up to 200 feet, use 16 AWG, THHN 600-volt insulated wire.

RFI Filter Installation

  • Use 22 AWG or larger (depending on the load) for all other connections. ALWAYS REMOVE POWER PRIOR TO SERVICING

An in-line ferrite RFI fi lter has been included with this unit to install during the wiring of the RE-1 Residential Telephone Entry System.

✦ NOTETo insure FCC Part 15 Class B compliance, the following steps

Earth Ground

must be performed at the time the RE-1 is installed. 1. Open the ferrite RFI fi lter case by gently pulling on the side locking tab and swinging the case open (see Figure 1). ★ CAUTION: The ferrite parts of the RFI fi lter are fragile.

To avoid damage to the unit from static discharges, connect the RE-1’s EARTH GROUND and case ground terminals to a good earth grounding point within 10 feet. The case ground terminal is the #8 screw located on the backplate above the wire entry hole. Also, the RE-1’s Telephone Bypass Module must be grounded to provide surge protection for the telephone line. Suggested wiring size is 12 AWG for earth ground.

DO NOT DROP THE FILTER ON A HARD SURFACE! Damage to the fi lter may result. 2. After completing the RE-1 installation, route all wires except the AC transformer and telephone lines through the grove in the ferrite core of the RFI fi lter. The fi lter must be installed outside of the RE-1 case. With the wires captured inside, close the ferrite RFI fi lter case and snap it shut (see Figure 1). ✦ NOTE: Be sure the fi lter is located no further than two inches from the

Removable Terminal Strips

For convenience, the RE-1 is provided with removable terminal strips. It is important that these strips be removed evenly in order to avoid causing permanent damage to them.

rear case cover of the RE-1.

1. Be certain power is off before removing or installing these strips.
2. With a small screwdriver, gently slide the blade between the terminal strip and protective label.
3. Slightly pry fi rst one end, then the other, and then the middle. Repeat the process until the terminal strip can be removed straight off the circuit board by hand. Be very careful to not damage circuit board traces.

RFI FILTER INSTALLED WITHIN 2" OF RE-1 CASE

4. When re-installing the terminal strips, press down straight and evenly. Do not remove or install one end fi rst. This will bend pins on the circuit board, which will damage the terminal strip internally. This damage is permanent and can not be repaired by simply straightening the pins on the circuit board.

PULL ON PLASTIC TAB TO UNLOCK FILTER CASE

SWING FILTER CASE OPEN

✦ NOTEUnscrew the terminal screws several turns before inserting

wires.

PHONE AND TRANSFORMER WIRES OUTSIDE OF FILTER

FERRITE CORE

Figure 1. RFI Filter Installation

Page 5 of the Linear Telephone Entry System (RE-1) user manual — COMPONENT LOCATIONS
Page 5 · click to enlarge
Page 5
Linear Telephone Entry System (RE-1) — COMPONENT LOCATIONS diagram (page 5)
Fig. 2
Linear Telephone Entry System (RE-1) — COMPONENT LOCATIONS diagram (page 5)
Fig. 3

COMPONENT LOCATIONS

12 RELAY TERMINAL BLOCK For Relay #1 and Relay #2 output connections to the access control devices.

1 KEYPAD Die-cast metal 12-key keypad with tactile action. For system programming and keying in entry codes.

13 RELAY INDICATORS Indicators for Relay #1 and Relay #2 will light when the relay is activated.

2 DOWNLIGHT Illuminates keypad and visitor operation buttons. The light can be programmed to operate dusk to dawn and adjusts its time depending on the system’s geographic location.

14 ANTENNA TERMINAL BLOCK For shield and center conductor connection of the coax cable from the system’s built-in radio antenna.

3 OPTIONAL CCTV CAMERA Location for the optional Model RE-BWC1 CCTV camera. The camera views the keypad area and has infrared lighting for nighttime use.

15 LINE MONITOR JUMPER For testing and troubleshooting. Remove jumper to listen to telephone line audio through the speaker.

4 MICROPHONE The high-sensitivity microphone monitors sound at the keypad area for the entry system’s speakerphone.

16 DIGITAL SPEECH VOLUME CONTROL Controls the audio level of the voice synthesizer. This adjustment effects the audio level of the voice synthesizer and system tone from the speaker.

5 CALL BUTTON Pressing this button causes the system to call the residence telephones with a distinctive ring signal.

17 STATUS INDICATORS Six indicators light to display system power, radio, and modem status.

6 HELP BUTTON Pressing this button causes the system to play the help message to instruct the visitor on system use.

18 VIDEO CONNECTOR For cable connection to a video monitor. (Optional Model RE-BWC CCTV camera required).

7 SPEAKER Weatherproof speaker for system operation and programming.

19 CAMERA CONNECTOR Provides power and video connection for the optional Model RE- BWC CCTV camera.

8 INTEGRAL ANTENNA Hidden antenna receives wireless radio signals from transmitters.

9 OPTIONAL KEYLOCK Location for mounting access keylock. (MEDECO keylock with stainless steel cover shown).

20 RESTART BUTTON Pressing this button restarts the system. This button DOES NOT erase any programming data.

10 MAIN TERMINAL BLOCK For power, backup battery, sense inputs, open request inputs, and remote keypad connections.

21 TELEPHONE TERMINAL BLOCK For telephone line and earth ground connections.

11 SPEAKERPHONE VOLUME CONTROL Controls the audio level produced by the speaker during communications between the visitor and the resident.

Page 6 of the Linear Telephone Entry System (RE-1) user manual — STAKE
Page 6 · click to enlarge
Page 6

WIRING DIAGRAM

Linear Telephone Entry System (RE-1) — WIRING DIAGRAM diagram (page 6)
Fig. 4

3 AMPS AT 30 VOLTS AC OR DC MAXIMUM

3 AMPS AT 30 VOLTS AC OR DC MAXIMUM

STAKE

STAKE

Page 7 of the Linear Telephone Entry System (RE-1) user manual — TO TELCO
Page 7 · click to enlarge
Page 7

ENTRY SYSTEM MOUNTING

TELEPHONE WIRING

Pedestal Mounting

The RE-1 connects between the incoming telephone line of the residence and local telephone sets.

The RE-1 Entry System can be mounted on a standard pedestal. 1. Open the RE-1 case by removing the two security screws with the wrench provided (see Figure 2). 2. Use four security bolts and locking nuts to secure the backplate to the pedestal (see Figure 3).

Telephone Bypass Module

The RE-1’s Telephone Bypass Module provides surge protection and a switch to remove the RE-1 from the telephone line and re-connect the local telephones to the telephone system. ALL TELEPHONE WIRING FOR THE RE-1 MUST PASS THROUGH THE BYPASS MODULE. The bypass module is housed in a weather-resistant enclosure and should be located in an area that is easily accessible to the resident. In case of system trouble, the resident can use the bypass switch to remove the RE-1 from the telephone system.

Wall Mounting

The RE-1 Entry System can be mounted directly to a wall or fl at surface. 1. Open the RE-1 case by removing the two security screws with the wrench provided (see Figure 2). 2. Use the appropriate fasteners to secure the system’s backplate to the mounting surface. When mounting the system to a concrete wall, use concrete wedge anchors (see Figure 4).

Telephone Wiring

  • DO NOT ROUTE TELEPHONE AND AC WIRING INSIDE THE SAME CONDUIT. Route all telephone wires inside a dedicated conduit that is at least six inches away from any AC line wiring.
  • All telephone wiring must be made on the “house” side of the telephone company’s demarcation device (the terminal block where the telephone line connects to the residence).
  • If any security system or personal alert system at the residence is connected to the telephone line, be sure that it is connected to the line ahead of the Telephone Bypass Module using a RJ-31X or RJ-38X interface.
  • Use only high-quality telephone wire rated for direct underground burial. All telephone wire should be twisted-pair with a minimum size of 24 AWG.

REMOVE THE TWO SECURITY SCREWS TO OPEN THE CASE

Typical Telephone Wiring

1. Connect the bypass module’s EARTH GROUND terminal to a good earth ground. 2. Before connecting the incoming telephone line to the bypass module check the polarity of the wires with a DC voltmeter. Connect the negative wire (RING - usually green) to the bypass module TELCO RING terminal. Connect the positive wire (TIP - usually red) to the bypass module TELCO TIP terminal. 3. Connect the resident’s local telephone line RING (usually green) to the bypass module HOUSE RING. Connect the local telephone line TIP (usually red) to the bypass module HOUSE TIP terminal. 4. Connect the RE-1 TELCO RING to the bypass module RE-1 TELCO RING terminal. Connect the RE-1 TELCO TIP to the bypass module RE-1 TELCO TIP terminal. 5. Connect the RE-1 HOUSE RING to the bypass module RE-1 HOUSE RING terminal. Connect the RE-1 HOUSE TIP to the bypass module RE-1 HOUSE TIP terminal.

Figure 2. Opening the RE-1 Case

PEDESTAL MOUNTING MOUNT BACKPLATE WITH SECURITY BOLTS AND LOCKNUTS

PEDESTAL CAUTION! BE SURE THE MOUNTING HARDWARE DOES NOT EXTEND MORE THAN 1/2" INSIDE THE BACKPLATE OR ELECTRICAL DAMAGE MAY OCCUR

Figure 3. Pedestal Mounting Backplate

TELEPHONE

BYPASS MODULE

EARTH

RE-1 ENTRY SYSTEM

TIP

TELCO

RING

CASE GROUND

TIP

HOUSE

RING

WALL MOUNTING

CASE GROUND SCREW

TO HOUSE

RING

PHONES

TIP

HOUSE

RING

RE-1 HOUSE

TIP

TELEPHONE

BYPASS MODULE

RING

RE-1 TELCO

USE WEDGE ANCHORS FOR CONCRETE OR OTHER APPROPRIATE ANCHORS FOR DIFFERENT MATERIALS

TIP

EARTH GROUND

GROUND

TO TELCO

RING

STAKE

LINE

TELCO

TIP

Figure 5. Telephone Wiring

Figure 4. Wall Mounting Backplate

Page 8 of the Linear Telephone Entry System (RE-1) user manual — RING
Page 8 · click to enlarge
Page 8

TELEPHONE WIRING OPTIONS

Intercom Mode

Shared Line

Pressing the Call button on the RE-1 will cause the RE-1 to generate a ring signal as if it were an intercom station. A live phone line is not used and the RE-1 provides power for the remote intercom phone.

This is the standard confi guration. The telephone line is routed through the RE-1 to the house phones. Pressing the Call button on the RE-1 will cause the RE-1 to disconnect the house phones from the telephone company line and generate a ring signal that is heard on the house phones.

✦ NOTEIn this mode, remote programming, call forwarding or alternate

resident calling is not available.

See PPN #52 for programming options.

CASE GROUND

TO HOUSE INTERCOM TELEPHONES

RING

HOUSE

RE-1 ENTRY SYSTEM

TIP

RING

RE-1 HOUSE

TO HOUSE

RING

TIP

TELEPHONE

PHONES

TIP

HOUSE

BYPASS MODULE

RING

RING

RE-1 TELCO

RE-1 HOUSE

TELEPHONE

TIP

EARTH GROUND

RING TIP RING TIP EARTH HOUSE TELCO RING TIP HOUSERING TIP TELCOEARTH

TIP

BYPASS MODULE

RING

RING

RE-1 TELCO

STAKE TIP

TELCO

TIP

EARTH GROUND

GROUND

FROM TELEPHONE

RING

TELCO

COMPANY

TIP

EARTH

RE-1 ENTRY SYSTEM

10' MAXIMUM WIRE RUN

TIP

10' MAXIMUM WIRE RUN

RING

TELCO

GROUND

GROUND

CASE GROUND

STAKE

STAKE

TIP

HOUSE

RING

Figure 6. Shared Line Wiring

Dedicated Line

Figure 8. Intercom Mode Wiring

Pressing the Call button on the RE-1 will cause the RE-1 to sieze the phone line and dial out to an outside number.

Ring Down Mode

Pressing the Call button on the RE-1 will cause the RE-1 to sieze the phone line and provide immediate communications with the PBX system.

See PPN #54 for programming options.

See PPN #54 for programming options.

CASE GROUND

RE-1 ENTRY SYSTEM

TO PBX SYSTEM

RING

RING

HOUSE

TIP

HOUSE

TIP

RING

RING

RE-1 HOUSE

RE-1 HOUSE

TELEPHONE

TIP

TELEPHONE

TIP

BYPASS MODULE

BYPASS MODULE

RING

RE-1 TELCO

RING

RE-1 TELCO

EARTH GROUND FROM TELEPHONE

TIP

TIP

EARTH GROUND

RING

RING

TELCO

TELCO

COMPANY

TIP

STAKE TIP

GROUND

RING

TIP

RING

TIP

EARTH

10' MAXIMUM WIRE RUN

HOUSE

TELCO

10' MAXIMUM WIRE RUN

GROUND

GROUND

EARTH

RE-1 ENTRY SYSTEM

STAKE

STAKE

TIP

TELCO

Figure 7. Dedicated Line Wiring

RING

CASE GROUND

TIP

RING

HOUSE

Figure 9. Ring Down Mode Wiring

Page 9 of the Linear Telephone Entry System (RE-1) user manual — TELEPHONE WIRING OPTIONS
Page 9 · click to enlarge
Page 9
MULTIPLE UNIT INSTALLATIONS Any of the four basic operation modes (Shared Line, Dedicated Line, Intercom, and Ring Down) may be used with multiple RE-1s in the same installation. The telephone line wiring is “daisy chained” (the telephone line routes through one unit to the next) as shown below. Always connect the telephone line + to TIP, and - to RING. The Telephone Bypass Module only performs the bypass function in the Shared Line Mode, but it will provide extra electrical surge protection in all modes. A surge on the TELCO terminals will be suppressed through the EARTH GROUND terminal. Always use separate AC transformers to power each RE-1. When multiple units are connected together, only two units can be controlled by resident telephone commands, and only one unit can be programmed to answer the telephone (PPN #33) for remote telephone commands. Remote programming via computer is not supported when using multiple RE-1s.Command Prefi x for Multiple Units Programming and relay control may be through the individual RE-1 keypads or through the house telephone(s) when using the Shared Line or Intercom Modes. To support using the house telephone(s) to issue commands, each RE-1 must be programmed to a different “command prefi x” (PPN #72). • Set one unit’s command prefi x to • Set the other unit’s command prefi x to In the case of simultaneous visitors at different units when using the Shared Line Mode, putting one RE-1 “on hold” to communicate with the second RE-1, then returning to the fi rst RE-1 is not recommended. Instead, fi nish all communications with the fi rst RE-1 before servicing the second RE-1. Simultaneous visitors at multiple units used on a single line wired in the Ring Down Mode will cause a “conference call” effect between units SHARED LINE FIRST LAST MODE RE-1 RE-1 ENTRY ENTRY SYSTEM SYSTEMINTERCOM PROGRAM THIS FIRST LAST MODE RE-1 UNIT ONLY FOR RE-1 RE-1 "INTERCOM MODE" ENTRY ENTRY (PPN #52) SYSTEM SYSTEM CASE CASE GROUND GROUND TO HOUSE HOUSE TELCO HOUSE TELCO TELEPHONES RING RING EARTH RING RING EARTH TIP RING HOUSE TIP RE-1 RING TELEPHONE HOUSE TIP BYPASS MODULE RE-1 RING TELCO TIP GE RA OR UT NH D TELCORI TN IG P T CE OLF E MR P PO H AM O NN YE G SR TO AU KN ED G SR TO AU KN ED G SR TO AU KN EDCASE CASE GROUND GROUND TO INTERCOM HOUSE TELCO HOUSE TELCO TELEPHONES RING RING EARTH RING RING EARTH TIP DO NOT CONNECT TO A LIVE TELEPHONE LINE RING HOUSE TIP RE-1 RING TELEPHONE HOUSE TIP BYPASS MODULE RE-1 RING TELCO TIP EARTH GROUND GROUND GROUND TELCORI TN IG STAKE STAKE P G SR TO AU KN ED DEDICATED LINE FIRST LAST MODE RE-1 RE-1 ENTRY ENTRY SYSTEM SYSTEM CASE CASE PROGRAM ALL GROUND GROUND RE-1 UNITS FOR "CALL FORWARDING" (PPN #54) HOUSE TELCO HOUSE TELCO EARTH EARTH RING TIP RING HOUSE TIP RE-1 RING TELEPHONE HOUSE TIP BYPASS MODULE RE-1 RING TELCO TIP EARTH FROM GROUND GROUND GROUND TELCORI TN IG T CE OOLE RMP PH BO XN YE STAKE STAKE P P A N G SR TO AU KN EDRING DOWN FIRST LAST MODE RE-1 RE-1 ENTRY ENTRY SYSTEM SYSTEM CASE CASE PROGRAM ALL GROUND GROUND RE-1 UNITS FOR "RING DOWN MODE" (PPN #54) IF DESIRED, CHANGE HOUSE TELCO HOUSE TELCO RESIDENT RESPONSE KEYS EARTH EARTH (PPN #71) RING TIP RING TIP RING TIP RING TIP RING HOUSE TIP RE-1 RING TELEPHONE HOUSE TIP BYPASS MODULE RE-1 RING TELCO TIP EARTH GROUND GROUND GROUND TELCORI TN IG F PR BO XM STAKE STAKE P G SR TO AU KN ED Figure 10. Multiple Unit Wiring
Page 10 of the Linear Telephone Entry System (RE-1) user manual — TIMER
Page 10 · click to enlarge
Page 10

CONTROL WIRING

Door or Pedestrian Gate Control

1. Install a low voltage electric door strike or magnetic lock as a locking device for the door or pedestrian gate. 2. Install the power supply or transformer for the locking device. DO NOT POWER THE RE-1 FROM THIS POWER SUPPLY. 3. Connect one wire from the power supply to one wire from the locking device. 4. Route two wires between the locking device and the RE-1. Connect one wire to the remaining wire of the locking device. Connect the other wire to the remaining wire of the power supply. • For a door strike, connect the wires to the RE-1 Relay #1 COM & N.O. terminals.

Gate Control

1. Route two wires between the gate and the RE-1. Connect the gate operator’s OPEN terminals to the RE-1 Relay #1 COM & N.O. terminals. ✦ NOTE: For operator wiring specifi cs, refer to the gate operator’s wiring

diagram. 2. If an access keyswitch is required refer to the Optional Keyswitch section of this manual for details on keyswitch wiring and installation. 3. If an external timer for preventing access at certain times is required, route two wires from the RE-1 to the timer contacts. Connect the timer contacts to the RE-1 SENSE #1 and COMMON terminals. ✦ NOTE: If the sense input is going to be used as an inhibit input, it must

  • For a magnetic lock, connect the wires to the RE-1 Relay #1 COM & N.C. terminals. 5. If an access keyswitch is required refer to the Optional Keyswitch section of this manual for details on keyswitch wiring and installation. 6. To use the door sense feature to detect forced entry or door ajar conditions, install a normally closed door switch on the door or pedestrian gate and route two wires from the switch to the RE-1. Connect the door sense switch to the RE-1 SENSE #1 and COMMON terminals. See programming PPN #24 & #27 to defi ne when Relay #2 will activate based on the sense input.

be programmed to select that input type. See programming PPN #29.

GATE OPERATOR (BEHIND GATE)

2 WIRES FOR DOOR SENSE SWITCH

4 WIRES FOR TELEPHONE

4 WIRES FOR TELEPHONE

DOOR SENSE SWITCH

RE-1 ENTRY SYSTEM

ELECTRIC DOOR STRIKE

2 WIRES FOR RE-1 POWER FROM TRANSFORMER

2 WIRES FOR DOOR STRIKE

NOTE: ROUTE TELEPHONE WIRES AWAY FROM POWER WIRES

2 WIRES FROM RE-1 TO GATE OPEN TERMINALS

2 WIRES FROM TRANSFORMER FOR RE-1 POWER

2 WIRES FOR DOOR STRIKE POWER FROM POWER SUPPLY

Figure 13. Door Installation Example Figure 11. Gate Installation Example

RELAY

RELAY

RELAY

RELAY

N.O.

COM

N.C.

N.O.

COM

N.C.

N.O.

COM

N.C.

N.O.

COM

N.C.

GATE OPERATOR OPEN

ELECTRIC DOOR STRIKE

RE-1 TERMINALS

RE-1 TERMINALS

REQUIRED WIRING

DOOR STRIKE POWER SUPPLY

TRANSFORMER

TRANSFORMER

TRANSFORMER

OPTIONAL WIRING

TRANSFORMER

BATTERY NEGATIVE

BATTERY NEGATIVE

REQUIRED WIRING

BATTERY POSITIVE

INHIBIT

BATTERY POSITIVE

SENSE #1

TIMER

SENSE #1

OPTIONAL WIRING

OPEN #1

OPEN #1

SENSE #2

SENSE #2

OPEN #2

ACCESS KEYSWITCH

OPEN #2

DOOR SENSE SWITCH

COMMON

COMMON

KEYPAD CLK

KEYPAD CLK

KEYPAD DVAL

KEYPAD DVAL

KEYPAD DAT 0

KEYPAD DAT 0

ACCESS KEYSWITCH

KEYPAD DAT 1

KEYPAD DAT 1

KEYPAD GND

KEYPAD GND

KEYPAD PWR

KEYPAD PWR

Figure 12. Gate Installation Wiring

Figure 14. Door Installation Wiring

Show 4 more labels / short text on this page
#1 · #2 · #1 · #2
Page 11 of the Linear Telephone Entry System (RE-1) user manual — OPEN #2
Page 11 · click to enlarge
Page 11

POWER, BATTERY, & GROUND WIRING

OPTIONAL REMOTE KEYPAD

Power Wiring

The optional Model AM-KP remote keypad can be used with the RE-1 entry system. A typical application for the remote keypad would be to control a second door or gate. Entry codes are the only method of access allowed at a remote keypad. The default system setting will cause the remote keypad to activate Relay #2. 1. Mount the AM-KP keypad onto a pedestal or to a wall. 2. Route 6-conductor cable from the RE-1 to the AM-KP. • For wire runs up to 300 feet use 24 AWG Belden Type 9931 or equivalent.

✦ NOTEDO NOT APPLY POWER UNTIL THE INSTALLATION IS

COMPLETE. 1. Route two wires between the RE-1 and the power transformer. • For power wire runs up to 100 feet, use 18 AWG, THHN 600-volt insulated wire.

  • For power wire runs up to 200 feet, use 16 AWG, THHN 600-volt insulated wire. 2. Connect the wires to the transformer. Connect the other end of the wires to the two RE-1 TRANSFORMER terminals.
  • For wire runs up to 600 feet use 20 AWG Weico Type 9405 or equivalent. 3. Set the DEVICE ADDRESS rotary switch in the AM-KP to match the remote keypad address in the RE-1 (default = 3). 4. Connect the 6-conductor cable as shown in Figure 17. 5. Secure and lock the AM-KP to its mounting plate.

Backup Battery

Use of battery backup is optional. It will allow the RE-1 to operate for short periods of time without AC power. Two 12-volt backup batteries in series are recommended to obtain the proper working voltage for the RE-1. A single 12-volt battery can be used, although the call waiting beeps and the ring voltage will be lower than normal when fi ve telephones are connected. The door or gate access device must use some type of battery backup for the entire system to be functional. Backup batteries will not fi t into the RE-1 housing. Protect the backup batteries inside a rain-tight NEMA enclosure suitable for the installation.

✦ NOTEBackup batteries are not required to maintain the RE-1 clock/

calendar and programming memory during power outages. 1. Route two wires between the RE-1 and the backup batteries. 2. Connect two 1.2 Amp/hour (minimum), 12-volt, gel cell batteries in series (Battery #1 negative to Battery #2 positive). 3. Connect the Battery #1 positive to the RE-1 BATTERY POSITIVE terminal. 4. Connect the Battery #2 negative to the RE-1 BATTERY NEGATIVE terminal. ✦ NOTE: The RE-1 does not supply battery charging current. An

external battery charger will be required to maintain the batteries.

Earth Ground

For the best ground, use size 12 gauge solid wire or larger to connect the to an 8-foot copper ground rod. Locate the ground rod next to the Power and Telephone company rods and bond the rods together with a new clamp. Do not disturb the clamps installed by the Power or Telephone Company. Alternately, connect to a cold water pipe for the earth ground. 1. Connect the RE-1 EARTH terminal to the earth ground wire. 2. Connect the Telephone Bypass Module EARTH GROUND terminal to the earth ground wire.

SET SWITCH TO NUMBER 3

Figure 16. Setting the Keypad Device Address

TRANSFORMER

RE-1 TERMINALS

TRANSFORMER

RE -1 TRANSFORMER

TRANSFORMER BATTERY NEGATIVE

TRANSFORMER BATTERY NEGATIVE

BATTERY POSITIVE

12 VOLT 1.2 AMP/HR BATTERY

12 VOLT 1.2 AMP/HR BATTERY

BATTERY POSITIVE

SENSE #1

USE BELDEN 9931 (24 AWG) CABLE FOR RUNS UP TO 300 FEET

OPEN #1

SENSE #1

NOTE: BACKUP BATTERIES WILL REQUIRE AN EXTERNAL CHARGER

SENSE #2

OPEN #1

USE WEICO 9405 (20 AWG) CABLE FOR RUNS UP TO 500 FEET

OPEN #2

RING

SENSE #2

COMMON

HOUSE

KEYPAD CLK

TIP

OPEN #2

RING

KEYPAD DVAL

RE-1 HOUSE

COMMON

KEYPAD DAT 0

TIP

TELEPHONE

KEYPAD CLK

CLK

RING

BYPASS MODULE

KEYPAD DAT 1

RE-1 TELCO

KEYPAD DVAL

DVAL

KEYPAD GND

TIP

EARTH GROUND

RING

KEYPAD DAT 0

DAT0

AM-KP REMOTE KEYPAD

KEYPAD PWR

TELCO

TIP

KEYPAD DAT 1

DAT1

RE-1 TERMINALS

RING

TIP

RING

TIP

EARTH

KEYPAD GND

GND

HOUSE

TELCO

GROUND

KEYPAD PWR

PWR

STAKE

Figure 15. Power, Backup Battery & Ground Wiring

Figure 17. Remote Keypad Wiring

Page 12 of the Linear Telephone Entry System (RE-1) user manual — KEYPAD DAT 0
Page 12 · click to enlarge
Page 12

OPTIONAL KEYSWITCH

A keyswitch can be installed in the RE-1 Entry System to provide keyed access. The RE-1 case is designed to accept the following keyswitch:

KNOX COMPANY MODEL 3501

KNOX COMPANY

800-552-5669 www.knoxbox.com

Keyswitch Installation

1. Disconnect the wiring harness connector and remove the antenna terminal block. Remove the four circuit board retaining screws and the RE-1 circuit board (see Figure 18). 2. Remove the screw and washer that retain the keyswitch hole access plate (see Figure 19). 3. Hold the lock cover and plastic spacer in place on the RE-1 case. Secure the assembly with four screws, lock washers, and nuts. Slide the keyswitch into the hole, oriented as shown (see Figure 20). Secure the keyswitch with the large switch nut. Use bolt cutters to trim the two screws closest to the case edge so they will clear the circuit board (see Figure 21). 4. Plug the two keyswitch snap-on wire leads (supplied with the switch) onto the keyswitch COM and N.O. pins (see Figure 21). 5. Replace the RE-1 circuit board. Secure the board with the four screws. Reconnect the antenna terminal block and wiring harness connector. 6. Connect one keyswitch wire to the RE-1 OPEN #1 terminal. Connect the other keyswitch wire to the RE-1 COMMON terminal.

INSTALL COVER PLATE AND SPACER WITH FOUR SCREWS, LOCKNUTS, & NUTS

COVER PLATE ASSEMBLY

SPACER

INSERT KEYSWITCH INTO HOLE WITH KEYSLOT ORIENTED AS SHOWN

Figure 20. Installing the Keyswitch

DISCONNECT THESE TWO CONNECTORS

COM

REMOVE CIRCUIT BOARD

N.O. SWITCH PINS

SWITCH SECURED WITH LARGE NUT BOLTS CUT SHORT TO CLEAR CIRCUIT BOARD

CONNECT SWITCH WIRES TO COM AND N.O. PINS

REMOVE THESE 4 SCREWS

Figure 18. Removing the RE-1 Circuit Board

Figure 21. Keyswitch Wire Connections

REMOVE THE SCREW AND WASHER

TRANSFORMER

RE-1 TERMINALS

TRANSFORMER

BATTERY NEGATIVE

BATTERY POSITIVE

SENSE #1

OPEN #1

SENSE #2

OPEN #2

ACCESS KEYSWITCH

COMMON

KEYPAD CLK

KEYPAD DVAL

KEYPAD DAT 0

KEYPAD DAT 1

REMOVE THE COVER PLATE

KEYPAD GND

KEYPAD PWR

Figure 22. Keyswitch Wiring Figure 19. Removing the Keyswitch Hole Access Plate

Page 13 of the Linear Telephone Entry System (RE-1) user manual — IMPORTANT!
Page 13 · click to enlarge
Page 13

OPTIONAL CCTV CAMERA

Linear’s Model RE-BWC1 (P/N ACP00886A) CCTV camera can be installed inside the RE-1 Entry System. The camera provides a video signal for viewing the area in front of the entry system. The camera is continuously powered by the RE-1. The camera’s infrared light emitters illuminate the area directly on front of the entry system for nighttime or low light operation. The RE -1 CAMERA jack is used to connect the camera to the main circuit board with the double-ended modular cable supplied with the camera. This cable routes power to, and video from the camera. The RE-1 VIDEO jack is for connection to a video cable with a Type “BNC” connector. Up to 300 feet of 75-ohm RG-59 video cable can be used. Longer cable runs may require the use of a video amplifi er.

Camera Installation

1. Disconnect the wiring harness connector and remove the antenna terminal block. Remove the four circuit board retaining screws and the RE-1 circuit board (see Figure 23). 2. Mount the camera assembly into the RE-1 case. Secure the camera with the two screws provided (see Figure 24). 3. Connect the wiring harness 2-pin lighting power wiring connector onto the camera’s infrared lighting power connector (see Figure 25). 4. Replace the RE-1 circuit board. Secure the board with the four screws. Reconnect the antenna terminal block and wiring harness connector. 5. Plug the double-ended modular cable into camera’s jack and the RE-1 CAMERA jack (see Figure 26). 6. Connect the video cable to the RE-1 VIDEO connector (see Figure 27).

INSERT WIRING HARNESS PLUG INTO THE 2-PIN LIGHTING CONNECTOR

Figure 25. Connecting the Camera’s Lighting Power

DISCONNECT THESE TWO CONNECTORS

PLUG THE CAMERA CABLE INTO THE CAMERA'S JACK AND THE RE-1'S CAMERA JACK

REMOVE CIRCUIT BOARD

CAMERA CABLE FROM CAMERA'S JACK

RE-1 CAMERA

JACK

REMOVE THESE 4 SCREWS

Figure 26. Connecting the Camera Cable

Figure 23. Removing the RE-1 Circuit Board

SECURE THE CAMERA ASSEMBLY WITH TWO SCREWS

CONNECT THE VIDEO CABLE FOR THE MONITOR TO THE RE-1'S VIDEO OUTPUT CONNECTOR

IMPORTANT!

TO PREVENT INTERNAL INFRARED LIGHT FROM ENTERING THE CAMERA, BE SURE THE FOAM GASKET AROUND THE CAMERA'S LENS PRESSES FIRMLY AGAINST THE RE-1'S FACEPLATE

Figure 24. Mounting the Camera in the RE-1

Figure 27. Connecting the Video Cable

Page 14 of the Linear Telephone Entry System (RE-1) user manual — Windows98™ Setup (SEE NEXT PAGES FOR WINDOWS XP™ AND WINDOWS VISTA™ SETUP)
Page 14 · click to enlarge
Page 14

PROGRAMMING ACCESS

3. Double-click on “Local RE-1”. (The Local RE-1 icon can be dragged to the desktop for easy future access). 4. Enter the RE-1’s programming master password (123456, unless changed) into the “Password” area. Select “Save Password” if you want the computer to retain the password. 5. Select “Connect” and wait for the modem to connect to the RE-1. 6. Switch to the browser software and enter into the address line: “http://192.168.20.10/re1.html” (save this address as a “favorite” or “bookmark” so you won’t have to enter it each time you connect). 7. Follow the screen links to select the RE-1 items to program. 8. When fi nished programming, double-click on the dial-up networking icon in the status area of the task bar and select “Disconnect” to terminate the connection. ✦ NOTE: Be sure to disconnect when programming is completed.

The RE-1 can be programmed locally or remotely. The system’s built-in programming software can be accessed on-site or off-site using a computer with any Internet browser. Without a computer, the RE-1 can be programmed from its main keypad, from any local TouchTone® telephone connected to the same line, or from any remote TouchTone® telephone by calling the unit. To guide you through the programming, the RE-1’s voice synthesizer will announce programming prompts over the telephone.

Programming with a Computer

Navigating through the RE-1’s programming “pages” is similar to browsing through your favorite web site’s pages. Anyone familiar with the Internet will fi nd programming the RE-1 with a computer very easy. The RE-1’s memory contains the “pages” that the computer will view. When selections and changes are made on the computer, the RE-1’s memory is programmed to your custom settings.

Creating Remote Computer Dial-up Connection 1. From “My Computer” select “Dial-up Networking” and select “Make New Connection”. 2. Name the connection “Remote RE-1” and verify that the installed modem is listed as the device the select “Next”. 3. For the telephone number enter the telephone number of the line that the RE-1 is installed on, select “Next”, then select “Finish”. 4. Right-click on “Remote RE-1” and select “Properties”. 5. From the “General” tab, in the “Connect Using” area, select “Confi gure...”. 6. From the “General” tab, in the “Speaker volume area”, set the volume to “High”. 7. Select the “Connection” tab. 8. Select “Advanced...” 9. In the “Use error control” area, de-select “Compress data” and select “OK” 10. Select “OK” again. 11. Select the “Server Types” or “Networking” tab. 12. In the “Advanced Options” area, de-select “Enable software compression”. 13. In the “Allowed network protocols” area, de-select “NetBEUI” and de-select “IPX/SPX Compatible”. Only “TCP/IP” should be selected. 14. Select “TCP/IP Settings...”. 15. Select “Specify an IP address”. 16. Enter “192.168.20.11” as the “IP address”. 17. De-select “Use IP header compression” and de-select “Use default gateway on remote network” then select “OK”. 18. Select “OK” again to complete the properties settings. Connecting Remotely 1. Start your browser software. If your browser is set to automatically dial your normal Internet provider when the browser is opened, cancel the dialing when it starts. 2. From “My Computer” select “Dial-up networking”. 3. Double-click on “Remote RE-1”. (The Remote RE-1 icon can be dragged to the desktop for easy future access). 4. Enter the RE-1’s programming master password (123456, unless changed) into the “Password” area. Select “Save Password” if you want the computer to retain the password. 5. Select “Connect” and wait for the modem to dial the RE-1. 6. Select “Cancel” after two rings. 7. Wait about 10 seconds, but not longer than 30 seconds, then repeat Steps 3-5. The RE-1 should answer. 8. Wait for the connection to establish. 9. Switch to the browser software and enter into the address line: “http://192.168.20.10/re1.html” (save this address as a “favorite” or “bookmark” so you won’t have to enter it each time you connect). 10. Follow the screen links to select the RE-1 items to program. 11. When fi nished programming, double-click on the dial-up networking icon in the status area of the task bar and select “Disconnect” to terminate the connection. ✦ NOTE: Be sure to disconnect when programming is completed.

System Requirements

✦ NOTEThese requirements are for a PC running the Windows™

operating system. For other types of computers and operating systems call Linear Technical Services for assistance. 1. A dial-up modem must be installed. 2. Dial-up networking must be installed. 3. An internet browser must be installed.

Windows98™ Setup (SEE NEXT PAGES FOR WINDOWS XP™ AND WINDOWS VISTA™ SETUP)

Creating a Local Computer Dial-up Connection 1. From “My Computer” select “Dial-up Networking” and select “Make New Connection”. 2. Name the connection “Local RE-1” and verify that the installed modem is listed as the device then select “Next”. 3. For the telephone number enter “###”, select “Next”, then select “Finish”. ✦ NOTE: The “###” prefi x to access programming is the default value for

the RE-1. It can be changed in the RE-1 using PPN #72. Be sure the prefi x entered as the telephone number matches what has been set in the RE-1 if it has been changed from the default. 4. Right-click on “Local RE-1” and select “Properties”. 5. From the “General” tab, in the “Connect Using” area, select “Confi gure...”. 6. From the “General” tab, in the “Speaker volume area”, set the volume to “High”. 7. Select the “Connection” tab. 8. Select “Advanced...” 9. In the “Use error control” area, de-select “Compress data” and select “OK” 10. Select “OK” again. 11. Select the “Server Types” or “Networking” tab. 12. In the “Advanced Options” area, de-select “Enable software compression”. 13. In the “Allowed network protocols” area, de-select “NetBEUI” and de-select “IPX/SPX Compatible”. Only “TCP/IP” should be selected. 14. Select “TCP/IP Settings...”. 15. Select “Specify an IP address”. 16. Enter “192.168.20.11” as the “IP address”. 17. De-select “Use IP header compression” and de-select “Use default gateway on remote network” then select “OK”. 18. Select “OK” again to complete the properties settings. Connecting Locally 1. Start your browser software. If your browser is set to automatically dial your normal Internet provider when the browser is opened, cancel the dialing when it starts. 2. Start “Dial-up networking”.

Page 15 of the Linear Telephone Entry System (RE-1) user manual — UN-CHECK THESE THREE BOXES
Page 15 · click to enlarge
Page 15

SETTING UP A WINDOWS XP™ DIAL-UP NETWORK CONNECTION

1. FROM CONTROL PANEL SELECT "NETWORK CONNECTIONS" THEN SELECT "NEW CONNECTION WIZARD"
2. THE NEW CONNECTION WIZARD WILL START CLICK "NEXT"
3. NEW CONNECTION WIZARD - "NETWORK CONNECTION TYPE" SELECT "CONNECT TO THE INTERNET" OPTION
Linear Telephone Entry System (RE-1) — SETTING UP A WINDOWS XP™ DIAL-UP NETWORK CONNECTION diagram (page 15)
Fig. 5
Linear Telephone Entry System (RE-1) — SETTING UP A WINDOWS XP™ DIAL-UP NETWORK CONNECTION diagram (page 15)
Fig. 6
Linear Telephone Entry System (RE-1) — SETTING UP A WINDOWS XP™ DIAL-UP NETWORK CONNECTION diagram (page 15)
Fig. 7
6. NEW CONNECTION WIZARD - "CONNECTION NAME" ENTER "RE-1 LOCAL" FOR A LOCAL CONNECTION OR "RE-1 REMOTE" FOR A REMOTE CONNECTION AS THE "ISP NAME"
4. NEW CONNECTION WIZARD - "GETTING READY" SELECT "SET UP MY CONNECTION MANUALLY"
5. NEW CONNECTION WIZARD - "INTERNET CONNECTION" SELECT "CONNECT USING DIAL UP MODEM"
Linear Telephone Entry System (RE-1) — SETTING UP A WINDOWS XP™ DIAL-UP NETWORK CONNECTION diagram (page 15)
Fig. 8
Linear Telephone Entry System (RE-1) — SETTING UP A WINDOWS XP™ DIAL-UP NETWORK CONNECTION diagram (page 15)
Fig. 9
Linear Telephone Entry System (RE-1) — SETTING UP A WINDOWS XP™ DIAL-UP NETWORK CONNECTION diagram (page 15)
Fig. 10
7. NEW CONNECTION WIZARD - "PHONE NUMBER TO DIAL" FOR A REMOTE CONNECTION, ENTER THE PHONE NUMBER OF THE RE-1'S PHONE LINE. FOR A LOCAL CONNECTION ENTER "###" (THE DEFAULT LOCAL ACCESS PASSWORD)
8. NEW CONNECTION WIZARD - "INTERNET ACCOUNT INFORMATION" ENTER "Linear" AS USER NAME AND "123456" AS PASSWORD
9. NEW CONNECTION WIZARD - "COMPLETING THE WIZARD" SELECT "ADD SHORTCUT" AND CLICK "FINISH"
Linear Telephone Entry System (RE-1) — SETTING UP A WINDOWS XP™ DIAL-UP NETWORK CONNECTION diagram (page 15)
Fig. 11
Linear Telephone Entry System (RE-1) — SETTING UP A WINDOWS XP™ DIAL-UP NETWORK CONNECTION diagram (page 15)
Fig. 12
Linear Telephone Entry System (RE-1) — SETTING UP A WINDOWS XP™ DIAL-UP NETWORK CONNECTION diagram (page 15)
Fig. 13

UN-CHECK THESE THREE BOXES

11. CLICK "PROPERTIES" TO SET OPTIONS 12. SELECT "NETWORKING" TAB, THEN CLICK PROPERTIES FOR "INTERNET PROTOCOL (TCP/IP)
13. SELECT "USE THE FOLLOWING IP ADDRESS" AND ENTER 192.168.20.11 THEN CLICK "ADVANCED...".
14. UN-CHECK "USE DEFAULT GATEWAY ON REMOTE NETWORK" AND UN-CHECK "USE IP HEADER COMPRESSION" THEN CLICK OK
Linear Telephone Entry System (RE-1) — UN-CHECK THESE THREE BOXES diagram (page 15)
Fig. 14
Linear Telephone Entry System (RE-1) — UN-CHECK THESE THREE BOXES diagram (page 15)
Fig. 15
Linear Telephone Entry System (RE-1) — UN-CHECK THESE THREE BOXES diagram (page 15)
Fig. 16
Linear Telephone Entry System (RE-1) — UN-CHECK THESE THREE BOXES diagram (page 15)
Fig. 17
10. DOUBLE-CLICK ON DESKTOP ICON TO LAUNCH THE CONNECTION WINDOW

BE SURE ONLY THESE FIRST TWO BOXES ARE CHECKED

Page 16 of the Linear Telephone Entry System (RE-1) user manual — 3. THE MODEM WILL DIAL THE NUMBER
Page 16 · click to enlarge
Page 16

CONNECTING TO THE RE-1 WITH WINDOWS XP™

1. DOUBLE-CLICK ON DESKTOP ICON TO LAUNCH THE CONNECTION WINDOW

2. CLICK "DIAL" TO START THE CONNECTION

Linear Telephone Entry System (RE-1) — 2. CLICK "DIAL" TO START THE CONNECTION diagram (page 16)
Fig. 18

3. THE MODEM WILL DIAL THE NUMBER

4. ONLY WHEN CONNECTING REMOTELY, AFTER THREE RINGS, CLICK "CANCEL", WAIT 10 SECONDS THEN REPEAT STEPS 1-3. THE RE-1 WILL ANSWER THE PHONE ON THE SECOND CALL ATTEMPT
Linear Telephone Entry System (RE-1) — 3. THE MODEM WILL DIAL THE NUMBER diagram (page 16)
Fig. 19
5. THE RE-1 WILL VERIFY THE USERNAME AND PASSWORD
6. AFTER CONNECTING, SWITCH TO YOUR MICROSOFT INTERNET EXPLORER BROWSER SOFTWARE AND ENTER THIS ADDRESS: http://192.168.20.10/re1.html
Linear Telephone Entry System (RE-1) — 3. THE MODEM WILL DIAL THE NUMBER diagram (page 16)
Fig. 20
Page 17 of the Linear Telephone Entry System (RE-1) user manual — 2. CLICK ON "SETUP A CONNECTION OR NETWORK"
Page 17 · click to enlarge
Page 17

SETTING UP A WINDOWS VISTA™ DIAL-UP NETWORK CONNECTION (PART 1)

1. FROM THE START MENU, CLICK ON "CONNECT TO"

2. CLICK ON "SETUP A CONNECTION OR NETWORK"

Linear Telephone Entry System (RE-1) — 2. CLICK ON "SETUP A CONNECTION OR NETWORK" diagram (page 17)
Fig. 21
Linear Telephone Entry System (RE-1) — 2. CLICK ON "SETUP A CONNECTION OR NETWORK" diagram (page 17)
Fig. 22
3. CHOOSE "SET UP A DIAL-UP CONNECTION" 4. CLICK ON THE MODEM TO BE USED FOR THE CONNECTION
Linear Telephone Entry System (RE-1) — 2. CLICK ON "SETUP A CONNECTION OR NETWORK" diagram (page 17)
Fig. 23
Linear Telephone Entry System (RE-1) — 2. CLICK ON "SETUP A CONNECTION OR NETWORK" diagram (page 17)
Fig. 24
5. FILL IN THE INFORMATION FOR THE CONNECTION 6. CLICK ON "SET UP THE CONNECTION ANYWAY"
Linear Telephone Entry System (RE-1) — 2. CLICK ON "SETUP A CONNECTION OR NETWORK" diagram (page 17)
Fig. 25
Linear Telephone Entry System (RE-1) — 2. CLICK ON "SETUP A CONNECTION OR NETWORK" diagram (page 17)
Fig. 26
Page 18 of the Linear Telephone Entry System (RE-1) user manual — 7. CLICK ON "CLOSE"
Page 18 · click to enlarge
Page 18

SETTING UP A WINDOWS VISTA™ DIAL-UP NETWORK CONNECTION (PART 2)

7. CLICK ON "CLOSE"

8. FROM THE START MENU, CLICK ON "CONNECT TO" AND SELECT "RE-1"
Linear Telephone Entry System (RE-1) — 7. CLICK ON "CLOSE" diagram (page 18)
Fig. 27
Linear Telephone Entry System (RE-1) — 7. CLICK ON "CLOSE" diagram (page 18)
Fig. 28
9. IN THE CONNECT WINDOW, SELECT "PROPERTIES" 10. CLICK ON "CONFIGURE" AND UN-CHECK ALL HARDWARE FEATURES
Linear Telephone Entry System (RE-1) — 7. CLICK ON "CLOSE" diagram (page 18)
Fig. 29
Linear Telephone Entry System (RE-1) — 7. CLICK ON "CLOSE" diagram (page 18)
Fig. 30
11. CLICK ON "OK" THEN CLICK ON "NETWORKING" TAB. HIGHLIGHT "INTERNET PROTOCOL VERSION 4 (TCP/IPv4)" AND CLICK ON "PROPERTIES"
12. CLICK ON "USE THE FOLLOWING IP ADDRESS" AND ENTER 192.168.20.11
13. CLICK ON "ADVANCED" AND UN-CHECK "USE IP HEADER COMPRESSION"
Linear Telephone Entry System (RE-1) — 7. CLICK ON "CLOSE" diagram (page 18)
Fig. 31
Linear Telephone Entry System (RE-1) — 7. CLICK ON "CLOSE" diagram (page 18)
Fig. 32
Linear Telephone Entry System (RE-1) — 7. CLICK ON "CLOSE" diagram (page 18)
Fig. 33
Page 19 of the Linear Telephone Entry System (RE-1) user manual — 2. THE MODEM WILL DIAL THE NUMBER
Page 19 · click to enlarge
Page 19

CONNECTING TO THE RE-1 WITH WINDOWS VISTA™

1. CLICK ON "DIAL" START THE CONNECTION

Linear Telephone Entry System (RE-1) — 1. CLICK ON "DIAL" START THE CONNECTION diagram (page 19)
Fig. 34
Linear Telephone Entry System (RE-1) — 1. CLICK ON "DIAL" START THE CONNECTION diagram (page 19)
Fig. 35

2. THE MODEM WILL DIAL THE NUMBER

3. ONLY WHEN CONNECTING REMOTELY, AFTER THREE RINGS, CLICK "CANCEL", WAIT 10 SECONDS THEN REPEAT STEPS 1-3. THE RE-1 WILL ANSWER THE PHONE ON THE SECOND CALL ATTEMPT
Linear Telephone Entry System (RE-1) — 2. THE MODEM WILL DIAL THE NUMBER diagram (page 19)
Fig. 36
4. THE RE-1 WILL VERIFY THE USERNAME AND PASSWORD
5. AFTER CONNECTING, SWITCH TO YOUR MICROSOFT INTERNET EXPLORER BROWSER SOFTWARE AND ENTER THIS ADDRESS: http://192.168.20.10/re1.html
Linear Telephone Entry System (RE-1) — 2. THE MODEM WILL DIAL THE NUMBER diagram (page 19)
Fig. 37
Page 20 of the Linear Telephone Entry System (RE-1) user manual — Programming with a Local Telephone or the Unit’s Keypad
Page 20 · click to enlarge
Page 20

LOCAL PROGRAMMING ACCESS

REMOTE PROGRAMMING ACCESS

Programming with a Local Telephone or the Unit’s Keypad

Remote Programming with a Telephone

Start with Step 1 below for local programming with the unit’s keypad or a local telephone. 1. Enter “###” (unless the programming prefi x has been changed) then the Master Programming Code (123456, unless it has been changed), then “#”. 2. Use the telephone keys or keypad to make any programming changes. Refer to the next section for details of the keystrokes for each programming PPN. The voice synthesizer will sound programming prompts. 3. To disconnect after programming, enter “99#”. ✦ NOTE: The RE-1 will automatically exit programming mode after fi ve

For remote programming, the RE-1 can be called from any TouchTone® telephone. Once the connection is made, the programming keystrokes are identical to what would be entered at the unit’s keypad or from a local telephone. Refer to the next section for details of the keystrokes for each programming PPN.

Remote Telephone Connection 1. Dial the telephone number of the line that the RE-1 is connected to. 2. Let the telephone ring twice and hang up. 3. After 10 seconds, but before 30 seconds, call back to the same telephone number. 4. The RE-1 will answer and sound a tone for 2 seconds. 5. The RE-1 will wait for approximately six seconds for the caller to enter the Master Programming Code. 6. Enter password (123456, unless it has been changed), then “#”. 7. Use the telephone keypad to make any programming changes. Refer to the next section for details of the keystrokes for each programming PPN. The voice synthesizer will sound programming prompts. 8. To disconnect after programming, enter “99#”.

minutes of no programming activity.

Page 21 of the Linear Telephone Entry System (RE-1) user manual — PROGRAMMING REFERENCE
Page 21 · click to enlarge
Page 21

PROGRAMMING REFERENCE

FACTORY DEFAULTS PPN 1 ENTRY CODE LENGTH 4 DIGITS PPN 8 TRANSMITTER LEFT (OR TOP LEFT) BUTTON ACTIVATES RELAY #1 TRANSMITTER RIGHT (OR TOP RIGHT) BUTTON ACTIVATES RELAY #2 TRANSMITTER TOP BUTTON ACTIVATES RELAYS #1 AND #2 TRANSMITTER LOWER LEFT BUTTON ACTIVATES NONE TRANSMITTER LOWER RIGHT BUTTON ACTIVATES NONE PPN 10 ENTRY TIME ZONES DISABLED PPN 12 HOLIDAYS NONE SET PPN 20 CLOCK & CALENDAR NOT SET PPN 21 RELAY #1 ON TIME 2 SECONDS PPN 22 RELAY #2 ON TIME 2 SECONDS PPN 23 MAIN KEYPAD ACTIVATES RELAY #1 OR #2 PPN 23 REMOTE KEYPAD ACTIVATES RELAY #2 PPN 24 RELAY #2 ALARM FUNCTION DISABLED PPN 26 MGT GATE EDGE TRANSMITTER DISABLED PPN 27 RELAY #2 ALTERNATE FUNCTION 2ND GATE OR DOOR PPN 28 REMOTE KEYPAD ADDRESS 3 PPN 29 SENSE INPUT ALTERNATE FUNCTION RELAY #1 SENSE RELAY #2 SENSE PPN 30 KEYPAD LOCKOUT COUNT 5 TRIES BEFORE LOCKOUT PPN 31 ANTI-PASSBACK TIME ANTI-PASSBACK DISABLED PPN 32 MAXIMUM NUMBER OF VISITOR RINGS 5 RINGS PPN 33 MODEM RING DETECT ON PPN 34 CALL FORWARDING DIALING METHOD TONE PPN 40 KEYPAD BEEPS ON PPN 41 RELAY #1 TONE OFF PPN 42 RELAY #2 TONE OFF PPN 43 RELAY TONE DURATION 1 SECOND PPN 44 VOICE SYNTHESIZER ON PPN 45 VISITOR TALK TIME LIMIT 60 SECONDS PPN 46 DAYLIGHT SAVING TIME AUTOMATIC ADJUSTMENT ON PPN 50 CALL WAITING FEATURE ON PPN 51 PRIVACY FEATURE OFF PPN 53 AUTOMATIC GATE/DOOR OPEN TIME NOT SET PPN 54 CALL FORWARDING FEATURE OFF PPN 55 ALTERNATE RESIDENT TELEPHONE NUMBERS ALL DISABLED PPN 71 RESIDENCE RESPONSE TELEPHONE KEYS 1 - ACTIVATE RELAY #1 2 - ACTIVATE RELAY #2 9 - DISCONNECT VISITOR 6 - SWITCH TO/FROM CALL WAITING PPN 72 RESIDENCE PROGRAMMING PREFIX ### PPN 72 RESIDENCE COMMAND PREFIX ## PPN 98 MASTER PROGRAMMING CODE 123456

PROGRAMMING CONTROL USAGE KEYSTROKES ENTER PROGRAMMING ###MASTER CODE# ESCAPE/CANCEL * EXIT PROGRAMMING 99#

PROGRAM POSITION NUMBERS (PPN) ENTRY CODE LENGTH PPN 1 PAGE 20 ADDING A NEW ENTRY CODE PPN 2 PAGE 20 REMOVING A SINGLE ENTRY CODE PPN 3 PAGE 20 ADDING TRANSMITTERS PPN 4 PAGE 21 SUSPEND OR ACTIVATE A SINGLE TRANSMITTER PPN 5 PAGE 21 ADDING A TEMPORARY ACCESS CODE PPN 6 PAGE 20 ASSIGNING TRANSMITTER BUTTONS TO RELAYS PPN 8 PAGE 21 SETTING THE TIME ZONES PPN 10 PAGE 20 SETTING THE HOLIDAY DAYS PPN 12 PAGE 20 SETTING THE CLOCK & CALENDAR PPN 20 PAGE 20 RELAY #1 ON TIME PPN 21 PAGE 22 RELAY #2 ON TIME PPN 22 PAGE 22 MAIN & REMOTE KEYPAD RELAY AND TIME ZONE PPN 23 PAGE 22 RELAY #2 ALARM FUNCTION PPN 24 PAGE 22 MGT GATE EDGE TRANSMITTER SETUP PPN 26 PAGE 22 RELAY #2 ALTERNATE OPTIONS PPN 27 PAGE 22 REMOTE KEYPAD ADDRESS PPN 28 PAGE 22 SENSE INPUT ALTERNATE FUNCTION PPN 29 PAGE 22 KEYPAD LOCKOUT COUNT PPN 30 PAGE 22 ANTI-PASSBACK TIME PPN 31 PAGE 22 MAXIMUM NUMBER OF VISITOR RINGS PPN 32 PAGE 21 MODEM RING DETECT ON/OFF PPN 33 PAGE 23 CALL FORWARDING DIALING METHOD PPN 34 PAGE 21 KEYPAD BEEPS ON/OFF PPN 40 PAGE 24 RELAY #1 TONE ON/OFF PPN 41 PAGE 24 RELAY #2 TONE ON/OFF PPN 42 PAGE 24 RELAY TONE DURATION PPN 43 PAGE 24 VOICE SYNTHESIZER ON/OFF PPN 44 PAGE 24 VISITOR TALK TIME LIMIT PPN 45 PAGE 21 DAYLIGHT SAVING TIME AUTOMATIC ADJUSTMENT ON/OFF PPN 46 PAGE 24 CALL WAITING ON/OFF PPN 50 PAGE 21 PRIVACY FEATURE SCHEDULE PPN 51 PAGE 21 INTERCOM MODE ON/OFF PPN 52 PAGE 21 AUTOMATIC DOOR/GATE OPEN TIME PPN 53 PAGE 24 CALL FORWARDING FEATURE PPN 54 PAGE 22 ALTERNATE RESIDENT TELEPHONE NUMBERS PPN 55 PAGE 22 RESIDENT RESPONSE TELEPHONE KEYS PPN 71 PAGE 22 RESIDENT PROGRAMMING & COMMAND PREFIXES PPN 72 PAGE 22 ERASING ALL TRANSMITTERS PPN 95 PAGE 21 ERASING ALL ENTRY CODES PPN 97 PAGE 20 CHANGING THE MASTER CODE PPN 98 PAGE 20 RESET SYSTEM DEFAULTS PPN 200 PAGE 22

✦ NOTEProgramming worksheets are supplied at the rear of this manual

for writing down other programming selections.

E D O C R E T S A M E D O C R E T S A M E D O C R E T S A M E D O C R E T S A M E D O C R E T S A M

Page 22 of the Linear Telephone Entry System (RE-1) user manual — Press: 000000 000000
Page 22 · click to enlarge
Page 22

BASIC SYSTEM PROGRAMMING

ENTRY CODE PROGRAMMING

Entering Programming Mode

Setting the Entry Code Length Default: 4 digits Sets the number of digits for all the entry codes programmed.

The 6-digit Master Programming Code (default = 123456) is used to enter Programming Mode from a local or remote telephone or the keypad.

PressLength Length = 2 - 6 for entry code length
PressMaster Code Master Code = the current 6-digit Master Programming Code
✦ NOTEIf the Entry Code Length is going to be changed from the factory

Exiting Programming Mode

default of four digits, make this change fi rst, before programming any entry codes. Adding a New Entry Code

Press✦ NOTE: The RE-1 will automatically exit Programming Mode after fi ve

Use this PPN to add up to 100 entry codes.

minutes of programming inactivity.

Press: Code Code Relay

Re-entering a Command After a Mistake

If an incorrect entry, or an incorrect key is pressed during programming, to clear the keypad:

Time Zone Code = The new entry code: 1-999999, depending on code length Relay = Relay that entry code will activate: 1 = Relay #1 2 = Relay #2 3 = Both Relays 4 = Latch Relay #1 (no access restrictions, latches relay, unlatch relay by re-entering code) Time Zone = 0 = no time zone; 1-7 to restrict access per time zone 1-7 If the new entry code chosen is already being used for another entry code, the system will reject the code. A new unique entry code needs to be entered.

Press:

Changing the Master Code

Use this PPN to change the six-digit Master Programming Code. Be sure to write down the new code.

Press: New Master Code New Master Code

Setting the Clock And Calendar

The time and date set in the clock and calendar control the system time zones, holiday schedules, and time stamping of the event log. The GTZ setting controls when the downlight is on. The RE-1 has an on-board lithium battery to maintain the date and time if power is removed from the unit.

✦ NOTE: Refer to PPN #23 for main and remote relay activation options.

Adding a Temporary Entry Code

Temporary entry codes with a starting and ending date can be created to permit limited access. Temporary entry codes will expire and no longer be able to grant access outside the programmed dates and a programmed number of uses. The total number of temporary and regular entry codes cannot exceed 100.

Press: Day of Week Month Day

Year Hour Minute AM/PM GTZ Day of Week: 1 = Sun; 2 = Mon; 3 = Tue; 4 = Wed; 5 = Thu; 6 = Fri; 7 = Sat

Press: Code Code Relay Time Zone

Month = 1-12; Day = 1-31; Year = 2000-2127; Hour = 1-12 (in standard, non-daylight saving time)

Minute = 0-59; AM/PM: 0 = AM; 1 = PM GTZ (Geographic Time Zone): 0 = None (disables nightime keypad lighting);

Number Valid From Valid Thru Code = The new entry code: 1-999999, depending on code length Relay = Relay that entry code will activate: 1 = Relay #1 2 = Relay #2 3 = Both Relays Time Zone = 0 = no time zone; 1-7 to restrict access per time zone 1-7 Number = Number of times (1-255) that the entry code is allowed access Valid From = First date (MMDDYY) that the entry code is valid Valid Thru = Last date (MMDDYY) the entry code is valid. If the new temporary entry code chosen is already being used for another entry code, the system will reject the code. A new unique temporary entry code needs to be entered.

1 = Eastern; 2 = Central; 3 = Mountain; 4 = Pacifi c; 5 = Alaska; 6 = Hawaii

Setting the Time Zones

Seven time zones are available for restricting access, automatic gate entry, call forwarding schedule, assigning an access groups for transmitters, assigning a temporary entry code, and setting the “Do Not Disturb” schedule. A time zone constrained event will be allowed or occur between the start and end times on the active days selected.

Press: Time Zone Number Active Days

✦ NOTE: Refer to PPN #23 for main and remote relay activation options.

Start Hour Start Minute AM/PM End Hour

Removing a Single Entry Code

Use this PPN to delete an entry code.

End Minute AM/PM Time Zone Number = 1-7 Active Days (Enter up to 8 digits): 1 = Sun; 2 = Mon; 3 = Tue; 4 = Wed; 5 = Thu; 6 = Fri; 7 = Sat; 8 = Holidays Start Hour = 1-12 Start Minute = 0-59 AM/PM: 0 = AM; 1 = PM End Hour = 1-12 End Minute = 0-59 AM/PM: 0 = AM; 1 = PM

Press: Code Code Code = The entry code to remove.

Erasing All Entry Codes

★ WARNING: This command will remove all entry codes.

Press: 000000 000000

Setting the Holiday Days

Up to ten holidays can be programmed. Holidays are used to restrict access on holiday days. If an entry method (code or transmitter) is assigned to a time zone, holidays must be set as an active day to allow access on holidays.

PressHoliday Number Month Day Holiday Number = 1-10 Month = 1-12 Day = 1-31
Page 23 of the Linear Telephone Entry System (RE-1) user manual — MDT-2
Page 23 · click to enlarge
Page 23

TRANSMITTER PROGRAMMING

TELEPHONE PROGRAMMING

Adding Transmitters

Maximum Number of Visitor Rings Default: 5 Rings Changes the maximum number of distinctive rings that the RE-1 will generate to the local telephones when the CALL button is pressed.

Up to 24 groups of transmitters can be assigned common access privileges sharing the same one or two time zones. Up to 100 transmitters total in all groups combined can be used in each RE-1 system.

PressRings Rings = 1-15 Rings maximum

Press: Number Facility Code First ID

Call Forwarding Dialing Method Default: Tone Sets the dialing method used during call forwarding to either tone or pulse style.

Time Zone 1 Time Zone 2 Number = Number of transmitters in the group Facility Code = Facility code 0-15 marked on block of transmitters; First ID = 5-digit ID number of fi rst transmitter in group. Time Zone 1 = 0 = no time zone; 1-7 to restrict access per time zone 1-7 Time Zone 2 = 0 = no time zone; 1-7 to restrict access per time zone 1-7

PressMethod Method: 1 = Pulse; 2 = Tone

Visitor Talk Time Limit Default: 60 Seconds Sets the time that the visitor is allowed to talk to the resident. Ten seconds before the time expires, the voice synthesizer will announce “ten seconds”, and at fi ve seconds it will announce “fi ve seconds”, to the visitor. If the voice synthesizer is disabled (PPN #44), a beep will sound each second during the last ten seconds of time allowed.

✦ NOTE: If the Time Zone 1 entry is set to “0”, the Time Zone 2 entry is

ignored.

Suspend or Activate a Transmitter

Each transmitter programmed can be individually suspended from use for access with this programming PPN. The transmitter will remain suspended until it is re-activated using this same programming PPN.

PressLimit Limit = 15-255 Seconds allowed

Press: Facility ID Action Facility = Facility code 0-15 of transmitter ID = 5-digit ID number of transmitter Action: 0 = Suspend transmitter; 1 = Re-activate transmitter

Call Waiting Feature On/Off Default: On Turns the call waiting feature on or off. If call waiting is on (factory default) and the resident is on the telephone at the same time a visitor calls, the RE-1 will generate beeps on the resident’s telephone line to signal that a visitor is calling. The resident has the option to switch to the visitor’s call. If the call waiting feature is off and the resident is on the telephone at the same time a visitor calls, the RE-1 will announce “resident busy” to the visitor.

Erasing All Transmitters

★ WARNINGPerforming this command will remove all

transmitters from the memory.

Press: 000000 000000

PressCall Waiting Call Waiting: 1 = ON; 0 = OFF

Assigning Transmitter Buttons to Relays Defaults: Left (or Top Left) = Relay #1 Right (or Top Right) = Relay #2 Top Button = Both Relays Lower Left = None Lower Right = None The RE-1 can be programmed to control which relay will activate from which transmitter button. This setting will effect all transmitters (single and multi-channel) used with the RE-1

Privacy Feature Schedule Default: Off The privacy feature will block visitor’s calls and call forwarding during the selected Time Zone or at all times. If the privacy feature is active and a visitor calls, the RE-1 will announce “do not disturb resident”. If call forwarding is scheduled (PPN #54) and the privacy feature is active, the RE-1 will announce “do not disturb resident” and visitor’s call will not be forwarded.

Press: Privacy Time Zone Privacy: 0 = Privacy feature OFF 1 = Privacy feature ON (scheduled by Time Zone) 2 = Privacy feature ON at all times Time Zone = 1-7 (Privacy feature active during this Time Zone)

Press: Button Relay Button: 1 = Right (or Top Right); 2 = Left (or Top Left) 4 = Top; 5 = Bottom Right; 6 = Bottom Left Relay: 0 = None; 1 = Relay #1; 2 = Relay #2; 3 = Both Relays

Intercom Mode On/Off Default : Off The RE-1 includes an Intercom Mode that allows the unit to be operated independent of the Public Switched Network. In this mode, the RE-1 directly supplies the power for the house telephone(s) connected to it. To use the RE-1 in intercom mode, connect the telephone line as shown under Telephone Wiring Options on Page 6. Note that the RE-1’s Telephone Bypass Module is included in the circuit for additional telephone line surge protection. Be sure the Telephone Bypass Module’s switch is in the NORMAL position.

BOTH FUNCTION

RIGHT BUTTON

AS LEFT BUTTON

LEFT BUTTON BOTTOM-LEFT

LEFT BUTTON

BUTTON

BOTTOM-RIGHT

ACT-31

BUTTON

ACT-34

SINGLE-CHANNEL

MDT

TRANSMITTERS

ACT-21

FOUR-CHANNEL

TRANSMITTER

Network, the call forwarding and alternate resident telephone dialing features will not be available. This programming step turns the intercom mode on or off. If intercom mode is on, the RE-1 will power the house telephone(s). If intercom mode is off, the Telephone Company will power the house telephone(s).

TOP BUTTON

TOP BUTTON

BOTH EQUALS

RIGHT BUTTON

TOP BUTTON

RIGHT BUTTON

LEFT BUTTON

LEFT BUTTON

RIGHT BUTTON

BOTTOM-RIGHT

LEFT BUTTON

BUTTON BOTTOM-LEFT

BUTTON

Press Intercom Mode

ACT-22

Intercom Mode1 = ON; 0 = OFF

MDT-2

MDT-4

THREE-CHANNEL

FIVE-CHANNEL

TRANSMITTER

TRANSMITTERS

Page 24 of the Linear Telephone Entry System (RE-1) user manual — Press: Location Enable
Page 24 · click to enlarge
Page 24

Call Forwarding Feature Default: OFF The call forwarding feature will allow a visitor to contact the resident at the programmed telephone number instead of through the local telephone line. The feature can be set to be active during a selected Time Zone or at all times. The telephone number programmed can contain an extension number and an optional time delay before dialing the extension.

Resident Response Telephone Keys Defaults: Key A “1” = Activates Relay #1 Key B “2” = Activates Relay #2 Key C “9” = Disconnect Visitor’s Call Key D “6” = Switch To/From Call Waiting The resident response keys are the telephone keys that the resident uses to grant access and control calls from a visitor. The keys for the four functions can be customized. Enter all four keys each time this programming PPN is used.

Press: Forwarding Time Zone

Telephone Number Extension Delay Forwarding: 0 = Call forwarding feature OFF 1 = Call forwarding feature ON at all times 2 = Call forwarding feature ON (scheduled by Time Zone) 3 = Forward the call if there was no resident answer Time Zone = 1-7 (Call forwarding feature active during this Time Zone) Telephone Number = Up to 11-digit telephone number Extension = Up to 4-digit telephone extension number Delay = 1-25 seconds (delay between telephone number and extension)

Press: Keys ABCD Keys ABCD: Enter 4 digits for the response keys A, B, C, & D Key A = Activates Relay #1 Key B = Activates Relay #2 Key C = Disconnects the Visitor’s Call Key D = Switches to and from a call holding on call waiting

Resident Programming and Command Prefi xes Defaults: Programming = “###”

Command = “##” The resident command prefi x is entered on a local telephone prior to entering a command number to control one of the relays or open voice communications with the RE-1. The resident programming prefi x is entered on a local telephone or the main keypad prior to programming the RE-1.

Example, call forwarding with only a phone number:

Press: or Telephone Number

A special feature is implemented for “Ring Down” PBX systems. If no telephone number is programmed and call forwarding is enabled, the unit will connect immediately without dialing.

Press: Programming Command Programming: 0 = “###”; 1 = “***”; 2 = “*#*”; 3 = “#*#” Command: 0 = “##”; 1 = “**”; 2 = “*#”; 3 = “#*” ADVANCED SYSTEM PROGRAMMING

Example, call forwarding with extension and no time zone:

Press: or Telephone Number

Reset System Defaults

Extension Delay

The system can be reset back to the factory defaults with this programming PPN. EXECUTING THIS PPN WILL NOT ERASE ANY ENTRY CODES OR TRANSMITTERS THAT HAVE BEEN PROGRAMMED.

Example, call forwarding scheduled by time zone:

Press: Time Zone Telephone Number

Press: Relay #1 On Time Default 2: Seconds Changes the length of time Relay #1 activates when triggered.

Extension Delay NOTETime zone is only used with forwarding = 2
PressTime Seconds = Output time in seconds 0-60

Example, call forwarding off:

Relay #2 On Time Default: 2 Seconds Changes the length of time Relay #2 activates when triggered.

Press:

PressTime Seconds = Output time in seconds 0-60

Alternate Resident Telephone Numbers Default: All Disabled For installations where multiple residences exist behind shared controlled access, the RE-1 can dial three alternate telephone numbers. The visitor can call an alternate number by entering “1#”, “2#”, or “3#” on the main keypad.

Main & Remote Keypad Relay and Time Zone Default: Main Keypad = Set by Entry Code, No Time Zone Remote Keypad = Relay #2, No Time Zone Sets the relay and time zone that the main and remote keypad will use.

Press: Location Enable

Press: Keypad Relay Time Zone Keypad: 1 = Main Keypad 2 = Remote Keypad (Also see PPN #28) Relay: 1 = Relay #1 2 = Relay #2 3 = Set by entry code Time Zone: 0 = no time zone 1-7 to restrict access per time zone 1-7

Telephone Number Extension Delay Location: 1 = “1#” location; 2 = “2#” location; 3 = “3#” location Enable: 0 = Disable; 1 = Unconditionally enable Telephone Number: Up to 11-digit telephone number Extension: Up to 4-digit telephone extension number Delay: 1-25 seconds (delay between telephone number and extension)

✦ NOTETo have an entry code select which relay activates, the relay

option should be set to “3”.

Page 25 of the Linear Telephone Entry System (RE-1) user manual — Model MGT Gate Edge Transmitter Setup
Page 25 · click to enlarge
Page 25

Relay #2 Alternate Options Default: Access Relay Relay #2 can be used for functions other than triggering a gate operator or door strike. Relay #2 can be programmed to shunt alarm contacts during Relay #1 activation or perform up to fi ve Alarm Functions. Two PPN numbers are used to program the Relay #2 options.

Sense Input Alternate Function Defaults: SENSE #1 = SENSE SENSE #2 = SENSE Each of the two SENSE inputs can be independently programmed to act as INHIBIT inputs. As an INHIBIT input, as long as the input is grounded, access can not be granted for that input’s relay (1 or 2). A typical application would be connection of an external timer or service switch to temporarily prevent visitors from activating the access device.

Press: Role Role: 0 = Access Relay 1 = Alarm Shunt (Follows Relay #1 activation, used to shunt external alarm contacts with Relay #2’s contacts) 2 = Obstacle Detector 3 = Activate during one or more of the fi ve Alarm Functions programmed below

Press: Input Type Input: 1 = SENSE #1 2 = SENSE #2 Type: 0 = Input will perform as SENSE 1 = Input will perform as INHIBIT

✦ NOTE: More than one alarm function can be enabled at a time. Up to fi ve

digits can be entered for “Activate”.

Keypad Lockout Count Default: 5 Tries The Keypad Lockout Count sets the number of incorrect code entry attempts required to place the keypad in “lockout” for a one minute period. During “lockout” the keypad will not accept any code entries. The Keypad Lockout Count effects both the main and remote keypads.

Press: Activate Activate: 0 = No alarm function (default) 1 = On forced entry (activates when SENSE #1 input opens without Relay #1 activation) 2 = On door/gate ajar (activates when SENSE #1 input stays open for longer than one minute after Relay #1 activation) 3 = On main keypad lockout (activates when the main keypad is in “lockout” from too many incorrect code attempts) 4 = On remote keypad lockout (activates when the remote keypad is in “lockout” from too many incorrect code attempts) 5 = On driveway sensor (activates when SENSE #2 input closes)

PressCount Count = 2-7 Incorrect entries

Anti-passback Time Default: Off The Anti-passback feature prevents the same entry code or transmitter from being used to gain access more than once during the set time.

PressTime Time: 0 = No anti-passback 1-4 = Anti-passback time (in minutes)

Model MGT Gate Edge Transmitter Setup

Linear’s Model MGT Gate Edge Transmitter can be used with the RE-1 for obstacle detection. When the gate edge sensor triggers the MGT transmitter, the RE-1 can be programmed to activate Relay #2 which would in turn, activate the obstacle input of the gate operator.

Modem Ring Detect On/Off Default: On The RE-1’s built-in modem monitors the telephone line for telephone rings. When the Modem Ring Detect is enabled, the modem will answer the telephone if two consecutive telephone calls occur within 30 seconds. The Modem Ring Detect can be disabled, this will also disable any computer based programming of the RE-1.

Press: Obstacle Facility ID Obstacle: 0 = No MGT obstacle transmitter (default) 1 = MGT obstacle transmitter used Facility: Facility code 0-15 of MGT transmitter ID = 5-digit ID number of transmitter

PressDetect Detect: 0 = Ring detect OFF 1 = Ring detect ON
✦ NOTEThe Facility and ID entries are not required if Obstacle is set to

“0”.

Remote Keypad Address Default: 3 If a Linear Model AM-KP is used as a remote keypad the ADDRESS switch in the remote keypad needs to match the “address” setting in the RE-1. For most installations, simply set the remote keypad’s ADDRESS switch to “3” to match the RE-1 default setting. If required, use the following programming PPN to change the address number.

PressAddress Address: 0 = Remote keypad disabled 1-6 = Keypad address 1-6
✦ NOTEAfter changing the keypad address, restart the system using the

RESTART button.

Page 26 of the Linear Telephone Entry System (RE-1) user manual — Digital Speech Volume
Page 26 · click to enlarge
Page 26

SYSTEM ADJUSTMENTS

Keypad Beeps On/Off Default: On The default setting causes the main keypad to beep when each key is pressed. The beeps can be disabled.

The RE-1 Entry System audio levels can be adjusted to suit the installation requirements. If required, make these adjustments after programming, but before closing and securing the RE-1 case.

PressKeypad Beeps Keypad Beeps: 0 = Beeps OFF 1 = Beeps ON

Speakerphone Volume

The SPEAKERPHONE VOLUME adjustment controls the audio level that the RE-1 speaker produces during communications between the visitor and the resident.

Relay #1 Tone On/Off Default: Off The default setting does not cause the annunciator to sound when Relay #1 is activated. The Relay #1 activation tone can be enabled.

✦ NOTEAdjusting the speaker volume too high will cause the speech
PressRelay #1 Tone Relay #1 Tone: 0 = Tone OFF 1 = Tone ON

to cut-out as the system switches from talk to listen. 1. Have someone waiting to receive the call. Push the CALL button to call the residence. 2. Have the resident talk at a normal volume level while adjusting the SPEAKERPHONE VOLUME control. Adjusting the control clockwise increases the volume, counterclockwise decreases the volume.

Relay #2 Tone On/Off Default: Off The default setting does not cause the annunciator to sound when Relay #2 is activated. The Relay #2 activation tone can be enabled.

Digital Speech Volume

PressRelay #2 Tone Relay #2 Tone: 0 = Tone OFF 1 = Tone ON

The DIGITAL SPEECH VOLUME adjustment controls the audio level of the voice synthesizer. This adjustment effects the audio level of the voice synthesizer from the speaker and through the telephone. 1. Push the HELP button to cause the voice synthesizer to sound the help message. 2. Adjust the DIGITAL SPEECH VOLUME to suit the installation. Adjusting the control clockwise increases the volume, counterclockwise decreases the volume.

Relay Tone Duration Default: 1 Second The default setting causes the annunciator to sound for 1 second when Relay #1 or Relay #2 is activated (if the tones are enabled). The length of the activation annunciation can be changed.

PressTone Length Tone Length = Tone length in Seconds 1-15

Voice Synthesizer On/Off Default: On When the voice synthesizer is on the RE-1 will sound voice prompts during operation and programming. If the voice synthesizer is off, the system will sound beeps to indicate conditions. The HELP button will announce “Enter code or press call button to contact resident” regardless of this setting. The beeps produced when the voice synthesizer is off are:

  • 1 Short beep — Keypad key pressed
  • 2 Short beeps — Programming entry was valid
  • 1 Long beep — Programming entry was invalid
PressVoice Voice: 0 = Voice synthesizer OFF 1 = Voice synthesizer ON

Automatic Daylight Saving Time Clock Adjustment On/Off Default: On The RE-1’s internal clock used for controlling system functions and time stamping of the event log automatically adjusts for daylight saving time. The time will change on the fi rst Sunday in April, and on the last Sunday of October. For areas where daylight saving time is not observed, this feature may be disabled.

Press: Daylight Saving Daylight Saving: 0 = Daylight Saving Adjust OFF 1 = Daylight Saving Adjust ON

Automatic Door/Gate Open Time Default: Not Set Each control relay can be programmed for automatic activation. One or two Time Zones can be assigned to a relay. The relay will activate and remain latched during the active period of the Time Zone.

Press: Relay 1st Time Zone 2nd Time Zone Relay: 1 = Relay #1 2 = Relay #2 1st Time Zone = Time Zone 1-7 2nd Time Zone = Time Zone 1-7 (enter “0” if the 2nd time zone is not used)

Page 27 of the Linear Telephone Entry System (RE-1) user manual — Requesting Access with a Visitor Call to an Alternate Number
Page 27 · click to enlarge
Page 27

RE-1 OPERATION

Residence Telephone Commands

  • The system can be controlled by the resident without a call from a visitor by using any telephone connected to the local line.

Requesting Access with an Entry Code

  • Visitors have up to 40 seconds to key in their entry code.
  • To activate and latch Relay #1 press
  • Up to eight seconds are allowed between each keystroke.
  • To activate and latch Relay #2 press
  • All digits of the entry code must be entered. Example: If the code is 0042, the user must enter “0 0 4 2”.
  • To release Relay #1 press
  • If the wrong key is pressed, pressing the key will reset the keypad. The correct code can then be entered.
  • To release Relay #2 press
  • To begin voice communications with the RE-1 press
  • After a correct code is entered, and if the conditions for granting access are fulfi lled, the programmed relay will activate for the programmed time.
✦ NOTEThe “##” command prefi x is programmable and can be changed
  • If the number of incorrect codes entered exceeds the keypad lockout count, the keypad will be locked and not accept any entries for one minute.

(see PPN #72).

Obstacle Transmitter Supervision

  • If the Model MGT obstacle transmitter has a supervisory condition, a one-second beep will be heard on any telephone connected to the local line when the telephone is off-hook (dialing during this beep is not recommended).
  • If the Anti-passback feature is enabled, the entry code will be unusable until the anti-passback time expires.

Requesting Access with a Wireless Transmitter

  • Activate a wireless transmitter within radio range (up to 300 feet) of the RE-1.
  • Servicing the MGT transmitter (replacing the batteries, correcting the tamper condition, etc.) will correct the supervisory condition and stop the one-second beeps.
  • After a valid transmitter is decoded, and if the conditions for granting access are fulfi lled, relay will activate for the programmed time.

Remote Telephone Commands

  • If the Anti-passback feature is enabled, the transmitter will be unusable until the anti-passback time expires.
  • The system can be operated from a remote phone. 1. Dial the phone number for the RE-1. Wait two rings then hang up. 2. Wait at least 10, but not longer than 30 seconds and re-dial the phone number for the RE-1. 3. The RE-1 will answer. Wait for the modem tones to fi nish then enter your 6 digit password followed by #. 4. The RE-1 will respond with “Entry OK”.

Requesting Access with a Visitor Call

  • The visitor presses the CALL button.
  • The RE-1 disconnects the local telephones from the incoming telephone line and generates distinctive rings to the local telephones.
  • The resident answers the call and converses with the visitor to determine if access will be granted.
  • To latch Relay #1 press
  • To latch Relay #2 press
  • If the resident is using the telephone at the same time a visitor calls, and the Call Waiting feature is enabled, the RE-1 will sound beeps on the telephone line to notify that a visitor is calling. The resident can place the outside caller on hold and switch to (and from) the visitor by
  • To release Relay #1 press
  • To release Relay #2 press
  • The RE-1 will respond with “Entry OK”.

pressing on the telephone.

  • The resident can use the telephone’s keypad to grant access activating
  • To disconnect press

Relay #1 by pressing , or activating Relay #2 by pressing .

  • The resident can disconnect the visitor without granting access by

pressing or by hanging up.

  • If the Call Forwarding feature is enabled, the system will forward the visitor’s call to an outside telephone number during the programmed time for call forwarding. The resident can control access from the forwarded telephone number.
  • The system can be programmed to produce a “Do Not Disturb” message for the visitor during times when privacy is desired. No call will be generated to the residence and access will be denied.
  • Pressing the key will cancel the call.
✦ NOTEThe telephone control keys are programmable and can be

changed (see PPN #71).

Requesting Access with a Visitor Call to an Alternate Number

  • The system can be programmed to provide up to three alternate telephone numbers to dial for installations where multiple residences are secured by shared controlled access.
  • The visitor can call the alternate telephone numbers by pressing:

, , or . The three numbers are defi ned by programming.

Page 28 of the Linear Telephone Entry System (RE-1) user manual — Setting the Holiday Days
Page 28 · click to enlarge
Page 28

RESIDENT PROGRAMMING QUICK REFERENCE

Maximum Number of Visitor Rings

Some of the programming PPN’s may be commonly used by the resident. Following are quick references to the keystrokes required.

Press: Rings

Rings = 1-15 Rings maximum

✦ NOTEThe “###” is the default command prefi x. The following example

assumes that the default has not been changed.

Visitor Talk Time Limit

Press: Limit

To Enter Programming Mode

Limit = 15-255 Seconds allowed

Press: Master Code

Master Code = the current 6-digit Master Programming Code

Call Waiting Feature On/Off

Press: Call Waiting

To Exit Programming Mode & Save Changes

Call Waiting1 = ON; 0 = OFF

Press:

Call Forwarding

Re-entering a Command After a Mistake

Press: Forwarding Time Zone Telephone Number

If an incorrect entry, or an incorrect key is pressed during programming, to clear the keypad:

Extension Delay

Forwarding: 0 = Call forwarding feature OFF 1 = Call forwarding feature ON at all times 2 = Call forwarding feature ON (scheduled by Time Zone) Time Zone = 1-7 (Call forwarding feature active during this Time Zone) Telephone Number = Up to 11-digit telephone number Extension = Up to 4-digit telephone extension number Delay = 1-25 seconds (delay between telephone number and extension) Example: Press: Telephone Number

Press:

Adding a Entry Code

Press: Code Code Relay Time Zone

Code = The new entry code: 1-999999, depending on code length Relay = Relay output entry code will activate: 1 = Relay #1 2 = Relay #2 3 = Both Relays 4 = Relay #1 as priority user (no access restrictions) Time Zone = 0 = no time zone; 1-7 to restrict access per time zone 1-7

“Do Not Disturb” Privacy Feature On/Off

Press: Privacy Time Zone

Privacy: 0 = Privacy feature OFF 1 = Privacy feature ON (scheduled by Time Zone) 2 = Privacy feature ON at all times Time Zone = 1-7 (Privacy feature active during this Time Zone)

Adding a Temporary Entry code

Press: Code Code Relay Time Zone Number

Valid From Valid Thru

Code = The new entry code: 1-999999, depending on code length Relay = Relay output entry code will activate: 1 = Relay #1 2 = Relay #2 3 = Both Relays Time Zone = 0 = no time zone; 1-7 to restrict access per time zone 1-7 Number = Number of times (1-255) that the entry code is allowed access Valid From = First date (MMDDYY) that the entry code is valid Valid Thru = Last date (MMDDYY) the entry code is valid.

Automatic Door/Gate Open Time

Press: Relay 1st Time Zone 2nd Time Zone

Relay: 1 = Relay #1 2 = Relay #2 1st Time Zone = Time Zone 1-7 2nd Time Zone = Time Zone 1-7 (enter “0” if the 2nd time zone is not used)

Removing a Single Entry Code

Setting Time Zones

Press: Code Code

Press: Time Zone Number Active Days Start Hour

Code = The entry code to remove.

Start Minute AM/PM End Hour End Minute AM/PM Time Zone Number = 1-7 Active Days (Enter up to 8 digits): 1 = Sun; 2 = Mon; 3 = Tue; 4 = Wed; 5 = Thu; 6 = Fri; 7 = Sat; 8 = Holidays Start Hour = 1-12 Start Minute = 0-59 AM/PM: 0 = AM; 1 = PM End Hour = 1-12 End Minute = 0-59 AM/PM: 0 = AM; 1 = PM

Suspend or Activate a Single Transmitter

Press: Facility ID Action

Facility = Facility code 1-16 of transmitter (0 = no facility code) ID = 5-digit ID number of transmitter Action: 0 = Suspend transmitter; 1 = Re-activate transmitter

Setting the Holiday Days

Press: Holiday Number Month Day

Holiday Number = 1-10 Month = 1-12 Day = 1-31

Page 29 of the Linear Telephone Entry System (RE-1) user manual — MOUNTING PLATE
Page 29 · click to enlarge
Page 29

SPECIFICATIONS

TROUBLESHOOTING

MECHANICAL Case dimensions: 6.45” W x 10.81” H x 3.74” D ELECTRICAL Voltage: 16 Volts AC or 12-24 Volts DC Current: 650 mA AC typical, 1300 mA AC maximum Backup Battery: Externally charged 12-24 Volt DC source Backup Battery Current: with 12-volt backup battery 250 mA standby 600 mA ringing one phone 1100 mA maximum with 24-volt backup battery 200 mA standby 350 mA ringing one phone 600 mA maximum Outputs: Relay #1 Form “C” 3 Amps @ 30 Volts maximum Relay #2 Form “C” 3 Amps @ 30 Volts maximum Inputs: Two normally closed door sense/inhibit inputs Two normally open request to exit inputs RADIO Frequency: 318 Mhz ± 500 KHz @ 23°C RF 3db Bandwidth: 4 MHz Typical Sensitivity: -97 dBm Minimum (-100 dBm Typical) Encoding: Linear MegaCode® Format ENVIRONMENTAL Temperature: -22°F to 149°F (-30°C to 65°C) Humidity: 5% to 95% non-condensing DIMENSION DRAWING

System will not go into programming mode

1. Wrong master code entered.

System completely dead

1. No power from transformer. Check voltage at RE-1 transformer terminals. 2. Verify that terminal blocks are fi rmly plugged into circuit board.

Buzz on speaker

1. Check for 24 volt AC power shorted to wiring conduit. 2. Check for telephone line shorted to ground. 3. Verify that telephone wires are twisted pair. 4. Verify that the RE-1 and the Telephone Bypass Module are connected to earth ground. 5. Check 16 VAC voltage at RE-1 transformer terminals.

Buzz on telephone line

1. Switch the Telephone Bypass Module to bypass. Connect line ring and tip to house ring and tip. Check line for buzz with test set. 2. Disconnect 16 VAC wires from terminal strip, if buzz goes away, one side of the transformer wires is grounded. 3. Check all connections for any shorts to ground.

Telephones in residence will not ring

1. Verify that the “Do Not Disturb” feature is not on while testing. 2. Verify that the Call Forwarding feature is not forwarding the calls at the time. 3. Check 16 VAC voltage at RE-1 transformer terminals. 4. Disconnect the house telephone line and connect a test telephone to the RE-1 house ring and tip terminals. See if the test telephone rings.

6.45" 3.74"

System will not answer an incoming call

1. Modem ring detect (PPN #33) disabled. 2. Calling pattern incorrect. Let telephone ring once, hang up, wait 10-30 seconds, then call again.

Call forwarding feature is not working

1. Incorrect phone number has been programmed (PPN #54) ✦ NOTE: If you are programming the call forwarding feature as “on at all

10.81"

times”, no programming entry is needed for the time zone (see example in PPN #54).

Entry code will not activate relay

1. Entry code not set up for proper relay (PPN #2). 2. Time zone is active for the relay.

Remote keypad does not work

1. Remote keypad address is not enabled (PPN #28). 2. Remote keypad relay is not selected (PPN #23).

5.95"

3.39"

Main or remote keypad will not activate a relay

1. Keypad is not assigned to a relay (PPN #23). 2. Entry code is not assigned to correct relay (PPN #2).

Gate does not open/close at programmed time

1. Time was not entered as local time (PPN #20). 2. Auto Daylight Saving Time disabled in area that observes daylight saving (PPN #46). 3. Automatic Door/Gate time zone is not properly programmed (PPN #53).

.28" DIA. 4 PLACES

Relay #1 will not latch from the keypad

2.75"

#8-32 TAPPED

1. Add an entry code with the relay programmed as a 4 (latch relay #1, PPN #2).

1.30" DIA.

2.75"

MOUNTING PLATE

Page 30 of the Linear Telephone Entry System (RE-1) user manual — PROGRAMMING WORKSHEET
Page 30 · click to enlarge
Page 30

PROGRAMMING WORKSHEET

S E N O Z E M I T S E N O Z E M I T S E N O Z E M I T S E N O Z E M I T S E N O Z E M I T

S Y A D E VIT C A S Y A D E VIT C A S Y A D E VIT C A S Y A D E VIT C A S Y A D E VIT C A E M IT T R A T S E M IT T R A T S E M IT T R A T S E M IT T R A T S E M IT T R A T S E M IT D N E E M IT D N E E M IT D N E E M IT D N E E M IT D N E

E N O Z E N O Z E N O Z E N O Z E N O Z N U S N U S N U S N U S N U S N O M N O M N O M N O M N O M E U T E U T E U T E U T E U T D E W D E W D E W D E W D E W U H T U H T U H T U H T U H T I R F I R F I R F I R F I R F T A S T A S T A S T A S T A S S Y A D IL O H S Y A D IL O H S Y A D IL O H S Y A D IL O H S Y A D IL O H R U O H R U O H R U O H R U O H R U O H E T U N I M E T U N I M E T U N I M E T U N I M E T U N I M M P/ M A M P/ M A M P/ M A M P/ M A M P/ M A R U O H R U O H R U O H R U O H R U O H E T U N I M E T U N I M E T U N I M E T U N I M E T U N I M M P/ M A M P/ M A M P/ M A M P/ M A M P/ M A

E M IT E M IT E M IT E M IT E M IT

Linear Telephone Entry System (RE-1) — PROGRAMMING WORKSHEET diagram (page 30)
Fig. 38

S Y A D I L O H S Y A D I L O H S Y A D I L O H S Y A D I L O H S Y A D I L O H

Linear Telephone Entry System (RE-1) — PROGRAMMING WORKSHEET diagram (page 30)
Fig. 39

Y A D IL O H Y A D IL O H Y A D IL O H Y A D IL O H Y A D IL O H E M A N E M A N E M A N E M A N E M A N H T N O M H T N O M H T N O M H T N O M H T N O M Y A D Y A D Y A D Y A D Y A D

E D O C R E T S A M E D O C R E T S A M E D O C R E T S A M E D O C R E T S A M E D O C R E T S A M

R E B M U N G N I D R A W R O F L L A C R E B M U N G N I D R A W R O F L L A C R E B M U N G N I D R A W R O F L L A C R E B M U N G N I D R A W R O F L L A C R E B M U N G N I D R A W R O F L L A C

1 R E B M U N E N O H P E L E T E T A N R E T L A 1 R E B M U N E N O H P E L E T E T A N R E T L A 1 R E B M U N E N O H P E L E T E T A N R E T L A 1 R E B M U N E N O H P E L E T E T A N R E T L A 1 R E B M U N E N O H P E L E T E T A N R E T L A

RESIDENT RESPONSE TELEPHONE KEY FOR RELAY #1 71 1

RESIDENT RESPONSE TELEPHONE KEY FOR RELAY #2 71 2

2 R E B M U N E N O H P E L E T E T A N R E T L A 2 R E B M U N E N O H P E L E T E T A N R E T L A 2 R E B M U N E N O H P E L E T E T A N R E T L A 2 R E B M U N E N O H P E L E T E T A N R E T L A 2 R E B M U N E N O H P E L E T E T A N R E T L A

RESIDENT RESPONSE TELEPHONE KEY FOR VISITOR DISCONNECT 71 9

RESIDENT RESPONSE TELEPHONE KEY FOR SWITCH TO/FROM CALL WAITING 71 6

3 R E B M U N E N O H P E L E T E T A N R E T L A 3 R E B M U N E N O H P E L E T E T A N R E T L A 3 R E B M U N E N O H P E L E T E T A N R E T L A 3 R E B M U N E N O H P E L E T E T A N R E T L A 3 R E B M U N E N O H P E L E T E T A N R E T L A

Page 31 of the Linear Telephone Entry System (RE-1) user manual — CONTROL WIRING
Page 31 · click to enlarge
Page 31

E D O C Y R T N E E D O C Y R T N E E D O C Y R T N E E D O C Y R T N E E D O C Y R T N E # Y A L E R # Y A L E R # Y A L E R # Y A L E R # Y A L E R E N O Z E M IT E N O Z E M IT E N O Z E M IT E N O Z E M IT E N O Z E M IT E D O C Y R T N E E D O C Y R T N E E D O C Y R T N E E D O C Y R T N E E D O C Y R T N E # Y A L E R # Y A L E R # Y A L E R # Y A L E R # Y A L E R E N O Z E M IT E N O Z E M IT E N O Z E M IT E N O Z E M IT E N O Z E M IT

R E S U R E T TI M S N A R T R E S U R E T TI M S N A R T R E S U R E T TI M S N A R T R E S U R E T TI M S N A R T R E S U R E T TI M S N A R T Y TILI C A F Y TILI C A F Y TILI C A F Y TILI C A F Y TILI C A F

E D O C E D O C E D O C E D O C E D O C E D O C D I E D O C D I E D O C D I E D O C D I E D O C D I E N O Z E M IT T S 1 E N O Z E M IT T S 1 E N O Z E M IT T S 1 E N O Z E M IT T S 1 E N O Z E M IT T S 1 E N O Z E M IT D N 2 E N O Z E M IT D N 2 E N O Z E M IT D N 2 E N O Z E M IT D N 2 E N O Z E M IT D N 2 P U O R G X T P U O R G X T P U O R G X T P U O R G X T P U O R G X T

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

2 _ _ 1 _ _ 2 _ _ 1 _ _

Page 32 of the Linear Telephone Entry System (RE-1) user manual — IMPORTANT WIRELESS INFORMATION
Page 32 · click to enlarge
Page 32

LINEAR LIMITED WARRANTY

FCC NOTICE

Changes or modifi cations not expressly described in this manual or approved by the manufacturer could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

This Linear product is warranted against defects in material and workmanship for twenty-four (24) months. The Warranty Expiration Date is labeled on the product. This warranty extends only to wholesale customers who buy direct from Linear or through Linear’s normal distribution channels. Linear does not warrant this product to consumers. Consumers should inquire from their selling dealer as to the nature of the dealer’s warranty, if any. There are no obligations or liabilities on the part of Linear LLC for consequential damages arising out of or in connection with use or performance of this product or other indirect damages with respect to loss of property, revenue, or profi t, or cost of removal, installation, or reinstallation. All implied warranties, including implied warranties for merchantability and implied warranties for fi tness, are valid only until Warranty Expiration Date as labeled on the product. This Linear LLC Warranty is in lieu of all other warranties express or implied. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help.

IMPORTANT WIRELESS INFORMATION

Linear radio controls provide a reliable communications link and fi ll an important need in portable wireless signaling. However, there are some limitations which must be observed.

  • For U.S. installations only: The radios are required to comply with FCC Rules and Regulations as Part 15 devices. As such, they have limited transmitter power and therefore limited range.
  • A receiver cannot respond to more than one transmitted signal at a time and may be blocked by radio signals that occur on or near their operating frequencies, regardless of code settings.
  • Changes or modifi cations to the device may void FCC compliance.
  • Infrequently used radio links should be tested regularly to protect against undetected interference or fault.
  • A general knowledge of radio and its vagaries should be gained prior to acting as a wholesale distributor or dealer, and these facts should be communicated to the ultimate users.

Copyright © 2008 Linear LLC 217490 C

Ask about the Linear Telephone Entry System (RE-1)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Linear Telephone Entry System (RE-1)

Be the first to ask — other owners or our team will answer.

Original document

Linear Telephone Entry System (RE-1) manual PDF

32 pages·1.1 MB·Network Router·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…