EN
Linear logo
Official user manual

Linear Intercom Station (LIN-501C)

2 pages·1.1 MB·Network Router·PDF·ENDEFRITNLJA
Linear Intercom Station (LIN-501C)
Table of Contents 13 sections AM-SEK / LIN-501C Quick Start Guide AM-SEK / LIN-501C Quick Start Guide · Communicating with the Access Network · Overview · Programming PC Overview · … ShowHide
Page 1 of the Linear Intercom Station (LIN-501C) user manual — LIN-501C General Specifications
Page 1 · click to enlarge
Page 1

AM-SEK / LIN-501C Quick Start Guide AM-SEK / LIN-501C Quick Start Guide

Communicating with the Access Network

Using Ping to Test IP Addresses 1. From the Windows START menu, select RUN. 2. Enter COMMAND (or CMD) into the OPEN: field and press OK. The DOS command prompt window will open. 3. To test an IP address enter PING and the IP address. 4. If the Ping command displays “Request timed out.” the IP address is not currently used. The address can be assigned to a LIN-501C module.

Overview

Programming PC Overview

Local Connecting with AccessBase2000

The AM-SEK Kit includes a LIN-501C Serial-to-Ethernet Module that provides a standard network TCP/IP connection for Linear’s AM3Plus, AE1000Plus, and AE2000Plus access controllers. The module can be used as an alternative to a traditional telephone modem typically used for remote access to Plus panel controllers.

At the installation site, a programming PC needs to be connected to the Local Area Network. This PC can be a permanent one in the installation, or can be a temporary PC brought in by the installer.

After opening the AccessBase2000 application, go to the network settings screen and set each active network to connect using the virtual COM port number (COM2 - COM8) that was setup to communicate with its LIN-501C module.

Administrator access will be required to setup the virtual COM ports on the PC. The virtual COM ports are assigned the IP address and port number of each LIN-501C module.

The LIN-501C module connects between the Plus panel’s RS‑232 Serial port and the installation’s Local Area Network (LAN). Access to the panel can be locally through the LAN or remotely from the Wide Area Network (WAN). Typically the module is connected to a port on a router located on the installation’s LAN.

Local Connecting with AXNET

If AccessBase2000 is used to manage the access network, it needs to be installed on the management PC. To avoid overwriting the installation’s database, don’t run AccessBase2000 remotely on a separate setup PC.

Linear Intercom Station (LIN-501C) — Local Connecting with AXNET diagram (page 1)
Fig. 1 · Local Connecting with AXNET

Create a Windows direct connect network when setting up for AXNET communications. Be sure to select the virtual COM port number assigned to the LIN-501C module for the “Communications Cable Between Two Computers” setting. Be sure to configure the port speed to 38400 bps.

In Plus panel networks, with multiple panels interconnected via RS‑485 wiring, the LN-501C module connects to Node #1 of an AXNET network, or Node #1 of any AccessBase2000 network.

If AXNET is going to be used to manage the access network, the PC will use a Windows direct connect network connection to communicate with the access network. Refer to Page 5 of AXNET manual P/N 226505 for details on setting up the Windows direct connect network connection.

Remote Connecting with AccessBase2000

After opening the AccessBase2000 application, go to the network settings screen and set each active network to connect using the virtual COM port number (COM2 - COM8) that was setup to communicate with the router’s external IP address and module’s public port number.

The LIN-501C does not replace the RS-485 and modem connections in a multiple access panel network. It does enable using an Ethernet network connection (instead of a direct serial connection or modem) between a Windows PC and supported Linear access panels to access and configure the panels using AXNET and/or AccessBase2000 applications.

5. If the Ping command displays replies from the IP address, the address is already being used by a device and cannot be assigned to a LIN-501C module.

Module Installation 1. Mount the LIN-501C module in a secure and weather protected location. 2. Connect the modular jack end of the A2C-DB9 cable to the RS-232 Port of the Linear “Plus” panel. 3. Connect the DB9 connector end of the A2C-DB9 cable to the COM port on the LIN-501C module. 4. Connect a CAT-5 network cable between the LAN connector on the LIN-501C module and an open port on the Local Area Network’s router (300 foot cable length maximum). 5. Route the wire from the power supply and connect the power supply cable RED (+) and BLACK (-) terminals on the plug-in terminal block. Plug the terminal block into the module. 6. Repeat Steps 1-5 for each additional LIN-501C module installed for different access networks in the installation. 7. When power is applied, a module’s RUN indicator should light and the LAN indicator should flash.

✓ ✓ NOTEIn existing installations, it is not recommended to
Linear Intercom Station (LIN-501C) — Remote Connecting with AccessBase2000 diagram (page 1)
Fig. 2 · Remote Connecting with AccessBase2000

connect with AccessBase2000 remotely on a separate setup PC. The installation’s database in the local PC could get overwritten, causing LOSS OF ALL CARDHOLDER DATA and other programming! Always backup installation data!

For easy configuration and setup, Windows® based software utilities are included on the installation CD. The utility software is used for setting up the LIN-501C module’s IP address and the computer’s virtual COM ports. The utility software is compatible with Windows XP®, Windows Vista®, and Windows 7®. To help with the module and router network configuration, a log sheet is provided to document the installation settings.

Remote Connecting with AXNET

Create a Windows direct connect network when setting up for AXNET communications. Be sure to select the virtual COM port number that was setup to communicate with the router’s external IP address and module’s public port number. Be sure to configure the port speed to 38400 bps. After the network connection is made and connected, use an Internet Web browser to connect to the AXNET panel.

Network Issues

Linear Intercom Station (LIN-501C) — Network Issues diagram (page 1)
Fig. 3 · Network Issues

Computer network topologies range from simple to complex. These instructions outline installation for a basic local area network. Large and complex networks may require setup that is beyond the scope of these instructions. If setup issues arise while configuring the LIN-501C module, seek assistance from the IT professional responsible for maintaining the network.

AM-SEK Kit Includes:

Software CD & Quick Start

LIN-501C General Specifications

✓ ✓ NoteLIN-501C Module is only available in the AM-SEK Kit and
Linear Intercom Station (LIN-501C) — LIN-501C General Specifications diagram (page 1)
Fig. 4 · LIN-501C General Specifications

is not sold separately.

Power: 12 VDC from plug-in power supply (included), also supports a 5 volt DC redundant input from an external power supply

Network Connection100BASE-T RJ-45 connector
Network SpeedFast Ethernet 10/100 Mbps
Serial ConnectionMale DB9 for connection with A2C/DB9 serial cable (included)

TO UP TO 7 MORE PLUS PANELS ON AN

Serial Port Speed38.4 Kbps
MountingDIN-rail or screw mounting

TO UP TO 3 MORE PLUS PANELS ON AN

Dimensions (LIN-501C Module)3-1/2” W x 3-3/4” H x 1” D

Weight: 6-1/2 ozs.

USA & Canada (800) 421-1587 & (800) 392-0123

(760) 438-7000 - Toll Free FAX (800) 468-1340

TYPICAL INSTALLATION WITH THE LIN-501C MODULE FUNCTIONING AS THE INTERFACE BETWEEN THE PLUS PANEL AND THE INSTALLATION'S LOCAL AREA NETWORK

www.linearcorp.com

Copyright © 2011 Linear LLC 231625 A

- 1 - - 4 -

Show 5 more labels / short text on this page
Guide · Power Adapter · Serial Cable · LIN-501C Serial-to-Ethernet · Module
Page 2 of the Linear Intercom Station (LIN-501C) user manual — Virtual COM Port Setup for Remote Access
Page 2 · click to enlarge
Page 2

AM-SEK / LIN-501C Quick Start Guide AM-SEK / LIN-501C Quick Start Guide

General LIN-501C Module Configuration 1. From the Windows START menu, select RUN. 2. Enter COMMAND (or CMD) into the OPEN: field and press OK. The DOS command prompt window will open. 3. Enter IPCONFIG and press ENTER. The current Windows IP configuration for the PC will be displayed. Write down the IP Address, Subnet Mask, and Default Gateway address numbers. Keep the window open for reference or enter EXIT to close it.

11. Write the settings in the log sheet to document the access network module and note the modules address settings. 12. Enter a name for HOST NAME to identify the module or the access network installation. 13. Press CONFIG NOW to send the configuration to the module. 14. The LIN-501C module should beep and an acknowledge window will display. Press OK .

Setup for Remote Off-Site Access

Linear Intercom Station (LIN-501C) — Setup for Remote Off-Site Access diagram (page 2)
Fig. 5 · Setup for Remote Off-Site Access

THE PROGRAMMING PC CONNECTS USING THE ROUTER'S EXTERNAL IP ADDRESS AND MODULE'S PUBLIC PORT NUMBER

The LIN-501C module installation and programming is identical for remote off-site access, the difference is in the router programming and the IP address used to communicate with the access network.

✓ ✓ NOTEFor remote access, the LIN-501C module(s) must be

connected to a router that supports a virtual server and has a STATIC external IP address. An Ethernet switch cannot be used.

PC Virtual COM Port Configuration 1. Launch the Vcom488.exe installation program from the utility CD. Install the virtual COM port program on to the PC as instructed by the installation wizard.

To be able to reliably connect with the router remotely over time, the router’s external IP address must be a static IP. A dynamic IP address will change over time, which would require changing the virtual COM port setting each session before connecting.

Linear Intercom Station (LIN-501C) — Setup for Remote Off-Site Access diagram (page 2)
Fig. 6 · Setup for Remote Off-Site Access

VIRTUAL SERVER SET FOR MODULE #1 IP: 192.168.249.150 PRIVATE PORT: 4660 PUBLIC PORT: 4001

PORT FORWARDING SET FOR MODULE #2 IP: 192.168.249.151 PRIVATE PORT: 4660 PUBLIC PORT: 4002

Linear Intercom Station (LIN-501C) — Setup for Remote Off-Site Access diagram (page 2)
Fig. 7 · Setup for Remote Off-Site Access
2. Select the virtual COM port(s) that will be used to connect to the LIN‑501C module(s). Press OK

Router Setup

Each LIN-501C module will have a unique IP address and will use private port number 4660. It’s the “port forwarding” or “virtual server” in the router that will resolve a public port number to each module’s IP address and private port number.

4. Insert the utilities CD into the PC’s CD-ROM drive and launch the monitor.exe application. (For convienience, the files can also be copied from the CD to the programming PC and run from there.)
✓ ✓ NOTESerial-IP supports virtual

COM ports 2-4096. AXNET can connect through any valid COM port. AccessBase2000 can only use ports 2-8. Each module in the installation will need a unique COM port assigned to the module’s IP address.

When connecting remotely to a module through the router’s virtual server, the router’s external IP address and module’s public port number are used.

✓ ✓ NOTEThe monitor.exe application has several buttons and

options that are not used for LIN-501C module setup. 5. Press the INVITE button. The application will display a list of all the LIN-501C modules discovered on the network.

Example address71.167.14.130:4001
  • 71.167.14.130 is the router’s external IP address
  • 4001 is the module’s public port number
Linear Intercom Station (LIN-501C) — Router Setup diagram (page 2)
Fig. 8 · Router Setup
3. In the SERIAL/IP CONTROL PANEL select a COM port to use to connect to a module. Be sure the CONNECT TO SERVER box is checked. Enter the module’s IP address in the IP ADDRESS field. Enter port 4660 into the PORT NUMBER field.
✓ ✓ NOTEAlthough similar, each manufacturer’s router model’s setup

Virtual COM Port Setup for Remote Access

screens are different. The “virtual server” may be called another name depending on manufacturer. Some routers do not support public to private port forwarding through a “virtual server”.

Linear Intercom Station (LIN-501C) — Virtual COM Port Setup for Remote Access diagram (page 2)
Fig. 9 · Virtual COM Port Setup for Remote Access

Follow these steps to setup the virtual COM ports for remote access: 1. Determine the exterior (WAN) IP address by checking the router’s device information page. 2. From the Windows START menu, launch the Serial-IP Control Panel application. 3. In the SERIAL/IP CONTROL PANEL select a COM port to use to connect to a module. Be sure the CONNECT TO SERVER box is checked. Enter the router’s external IP address in the IP ADDRESS field. Enter the module’s public port number that was set up for the module in the virtual server into the PORT NUMBER field.

The router will need to be setup on-site from a PC connected to the Local Area Network. Following is a typical router setup procedure: 1. On a PC connected to the router, open a browser window. 2. Enter the internal IP address of the router in the address bar of the browser. The router’s login screen should be displayed. 3. Enter the username and password. Unless the router login has been reprogrammed, the typical default username is admin, and the password is blank. Click the OK to log into the router.

✓ ✓ NOTEThe monitor.exe application can only detect modules

located on the LAN side of the same router as the PC. 6. From the displayed list, select the IP address of the module to program. (To help to identify modules, checking the LOCATE box will cause the selected module to beep.) Press CONFIG. 7. The configuration for the selected module displays showing the fixed MAC address and currently programmed IP, Gateway, and Subset Mask addresses. 8. A static IP address is required for the LIN-501C module. Verify that the AUTO IP box is un-checked. 9. To allow the module to communicate with the PC on the same network, the first three octets (xxx.xxx.xxx) of the LIN‑501C module’s IP address must to be set to the same as the programming PC’s IP address. Set the first three octets for the module’s addresses into the IP ADDRESS field. To avoid conflicts with existing network devices, choose a high number from 150-254 for the forth octet. Example: PC = 192.168.242.72 Module = 192.168.242.150

4. Press CONFIGURATION WIZARD . The Configuration window will be displayed. To test the PC’s COM port serial-to-IP connection, press START .
Linear Intercom Station (LIN-501C) — Virtual COM Port Setup for Remote Access diagram (page 2)
Fig. 10 · Virtual COM Port Setup for Remote Access
Linear Intercom Station (LIN-501C) — Virtual COM Port Setup for Remote Access diagram (page 2)
Fig. 11 · Virtual COM Port Setup for Remote Access
✓ ✓ NOTEIf you cannot login to the router successfully, consult
4. Press CONFIGURATION WIZARD . The Configuration window will be displayed. To test the PC’s COM port serial-to-IP connection, press START .
5. The status area will show the progress of the test. Green check marks indicate that the connection is OK. Red check marks indicate failures in the test. If the test fails, verify the address and port settings of both the module and the PC. Be sure the first three octets of the LIN‑501C module’s IP address match the PC. Press USE SETTINGS to exit the wizard.

with the IT personnel at the installation for assistance. 4. Virtual server or port forwarding is usually in the Advanced area of the router setup. Refer to the router manufacturer’s documentation. 5. For each LIN-501C module connected to the router, enter the module’s IP address, the module’s private port number (always 4660) and an unused unique public port number. Be sure to setup and enable a virtual server for each module connected.

5. The status area will show the progress of the test. Green check marks indicate that the connection is OK. Red check marks indicate failures in the test. If the test fails, verify the address and port settings. Press USE SETTINGS to exit the wizard.
6. Repeat Steps 2 through 5 for any additional LIN-501C modules in the installation.
✓ ✓ NOTEEach public port number chosen for modules must be

unique and currently available (unused). 6. For “traffic type” select TCP, for “schedule” select always. Terms will vary per router model. 7. Each connection may also be able to be given a name. Enter a descriptive name for the location of each LIN-501C module. This will help to identify the module’s router settings to yourself or others in the future. 8. After setting up the router, be sure to select SAVE SETTINGS in the router.

7. When finished, press CLOSE to exit the SERIAL/IP CONTROL PANEL .

Write the settings in the log sheet to document the virtual COM port and virtual server address settings.

6. Repeat Steps 2 through 5 for any additional LIN-501C modules in the installation.
✓ ✓ NOTEThe IP address for each LIN-501C module in an

installation must be unique and not conflict with other devices on the network. The DOS PING command can be used to check if an IP address is currently used or vacant (see Page 4). 10. Set the Gateway and Subnet Mask addresses to the same as the programming PC.

7. When finished, press CLOSE to exit the SERIAL/IP CONTROL PANEL . (The SERIAL-IP control panel can be restarted at any time from the Windows START menu.)

- 3 - - 2 -

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Linear Intercom Station (LIN-501C)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Linear Intercom Station (LIN-501C)

Be the first to ask — other owners or our team will answer.

Original document

Linear Intercom Station (LIN-501C) manual PDF

2 pages·1.1 MB·Network Router·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…