EN
Linear logo
Official user manual

Linear MDR-U

1 pages·174 KB·Garage Door Opener·PDF·ENDEFRITNLJA
Linear MDR-U
Table of Contents 67 sections IMPORTANT SAFETY INSTRUCTIONS · This symbol is intended to alert the user to the presence of · un-insulated “dangerous voltage” within the product’s enclosure that · important operating and maintenance (Servicing) instructions in the · … ShowHide
IMPORTANT SAFETY INSTRUCTIONSp.1This symbol is intended to alert the user to the presence ofp.1un-insulated “dangerous voltage” within the product’s enclosure thatp.1important operating and maintenance (Servicing) instructions in thep.1IS NOT CONTROLLED BY A WALL SWITCHp.1LEARN & SIGNALp.1INDICATORp.1BUTTONp.1NOTE: BE SURE THAT THE OUTLETp.1EXPLANATION OF GRAPHIC WARNING SYMBOLSp.1LEARNp.1RISK OF ELECTRICAL SHOCKp.11 AMP @ 32 VDC MAXIMUMp.1RECEIVER INTO THE 110 VAC OUTLETp.1DO NOT OPENp.1RELAY OUTPUTp.1TERMINALSp.1CAUTIONp.1REMOVE THE OUTLET'S COVERp.1PLATE SCREW AND PLUG THEp.1AC POWERp.1SECURE THE RECEIVERp.1THE RETAINING SCREWp.1TO THE OUTLET WITHp.1RETAININGp.1SCREWp.1ANTENNAp.1The Model MDR-U Universal MegaCode™ Receiver is designed for use as ap.1replacement radio control receiver in garage door operator installations. Thep.1receiver is self-contained, not requiring an external transformer or power from thep.1programmed by sending a signal from the transmitter, storing the transmitter’s codep.1The receiver will activate only from these “memorized” transmitters. Each MDR-Up.1transmitters in the receiver’s memory. The learn indicator also displays signalsp.1PUSHBUTTONp.1MDR-Up.1DISCONNECT POWER TO THE GARAGEp.1DOOR OPERATOR BEFORE PROCEEDINGp.1USED WITH THE OPERATOR MUST BE UL LISTEDp.1UL NOTE: ALL LOW VOLTAGE CLASS 2 CABLEp.1WITH EQUIVALENT OR BETTER ELECTRICAL,p.1MECHANICAL, AND FLAMMABILITY RATINGSp.1OPERATORp.1FROMp.1WALL PUSHBUTTONp.1CONNECTIONp.1(760) 438-7000 • FAX (760) 438-7043p.1SECURE THEp.1THE WALL PUSHBUTTON USES)p.1WIRE WITHp.1INSULATEDp.1STAPLESp.1OPERATOR TERMINALS 1 & 2p.1(OR THE SAME TERMINALSp.1Installation Instructionsp.1TO EITHER THE WALL PUSHBUTTON ORp.1DIRECTLY TO THE DOOR OPERATORp.1ROUTE THE WIRE AND CONNECT ITp.1MDR-U RECEIVER RELAY OUTPUT TERMINALSp.1PRODUCT DESCRIPTIONp.1(POLARITY NOT IMPORTANT)p.1For Garage Door Operatorp.1CONNECT 2-CONDUCTOR WIRE TO THEp.1MegaCode ™p.1DIRECT OPERATORp.1Universalp.1Receiverp.1Remote Controlp.1
Page 1 of the Linear MDR-U user manual — WIRE WITH
Page 1 · click to enlarge
Page 1

IMPORTANT SAFETY INSTRUCTIONS

MDR-U Universal MegaCode™ Receiver For Garage Door Operator Remote Control Installation Instructions (760) 438-7000 • FAX (760) 438-7043 USA & Canada (800) 421-1587 & (800) 392-0123 Toll Free FAX (800) 468-1340 www.linearcorp.com PRODUCT DESCRIPTIONCAUTION RISK OF ELECTRICAL SHOCK DO NOT OPEN EXPLANATION OF GRAPHIC WARNING SYMBOLS This symbol is intended to alert the user to the presence of un-insulated “dangerous voltage” within the product’s enclosure that may be of suffi cient magnitude to constitute a risk of electric shock. ✶ WARNING! To reduce the risk of fi re or electric shock, do not expose this device to rain, water, or wet locations. This symbol is intended to alert the user to the presence of important operating and maintenance (Servicing) instructions in the literature accompanying the device. COMPONENT LOCATIONSIMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF SEVERE INJURY OR DEATH 1. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS 2. NEVER LET CHILDREN OPERATE, OR PLAY WITH DOOR CONTROLS! KEEP REMOTE CONTROL AWAY FROM CHILDREN! 3. ALWAYS KEEP MOVING DOOR IN SIGHT AND AWAY FROM PEOPLE AND OBJECTS UNTIL IT IS COMPLETELY CLOSED. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR. 4. NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR. CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK, DISCONNECT POWER TO THE RECEPTACLE BEFORE INSTALLING OR REMOVING THE UNIT. WHEN REMOVING RECEPTACLE COVER SCREW, COVER MAY FALL ACROSS PLUG PINS OR RECEPTACLE MAY BECOME DISPLACED. USE ONLY WITH DUPLEX RECEPTACLE HAVING CENTER SCREW. SECURE UNIT IN PLACE BY RECEPTACLE COVER SCREW. DETERMINE THE BEST RECEIVER LOCATIONIMPORTANT SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifi ers) that produce heat. 8. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fi t into your outlet, consult an electrician for replacement of the obsolete outlet. 9. Unplug this apparatus during lightning storms or when unused for long periods of time. 10. Refer all servicing to qualifi ed service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. CHECK FOR INTERFERENCE FROM OTHER RECEIVERS The Model MDR-U Universal MegaCode™ Receiver is designed for use as a replacement radio control receiver in garage door operator installations. The receiver is self-contained, not requiring an external transformer or power from the garage door operator. The receiver plugs directly into a 120 VAC outlet. A retaining screw is provided to secure the receiver to the outlet. Two screw terminals on the receiver are for connection to the garage operator’s pushbutton input. A dry contact, Form “A”, relay in the receiver will provide a .5-seconds closure across the terminals when the receiver activates. A fl exible wire antenna extends from the receiver’s case to provide maximum radio reception. MegaCode™ receivers and transmitters do not contain a typical “coding switch”. Each transmitter is pre-set at the factory to a unique code. The receiver is programmed by sending a signal from the transmitter, storing the transmitter’s code into the receiver’s memory. The receiver will retain its memory, even without power. The receiver will activate only from these “memorized” transmitters. Each MDR-U receiver can be programmed to activate from up to ten MegaCode™ transmitters. The learn button and learn indicator are used for entering and erasing the transmitters in the receiver’s memory. The learn indicator also displays signals being received and can be used for troubleshooting. CONNECT THE RECEIVER TO THE OPERATORAC POWER RETAINING TERMINALS LEARN & SIGNAL SCREW INDICATOR ANTENNA RELAY OUTPUT LEARN TERMINALS BUTTON 1 AMP @ 32 VDC MAXIMUM INSTALL THE RECEIVERBEST RECEPTION A PLUG ON THE CEILING WILL GIVE THE BEST RADIO RECEPTION (UNLESS THE OPERATOR'S RECEIVER CAUSES SOME INTERFERENCE) GOOD RECEPTION A PLUG ABOVE A PLUG CLOSE THE GROUND LEVEL TO GROUND LEVEL WILL PROVIDE POOR WILL CAUSE GOOD RADIO RECEPTION POOR RADIO RECEPTION RECEPTION PROGRAM AND TEST THE RECEIVERWATCH THE MDR-U RECEIVER'S IF THE LEARN INDICATOR IS FLASHING WITHOUT ACTIVATING ANY TRANSMITTERS, LEARN INDICATOR INTERFERENCE MAY BE COMING FROM A NEARBY OPERATOR'S RECEIVER TEST IF THE OPERATOR IS THE SOURCE OF THE INTERFERENCE BY UN-PLUGGING THE OPERATOR FROM POWER IF THE LEARN INDICATOR STOPS FLASHING, THE OPERATOR IS THE SOURCE OF INTERFERENCE 1. IF THE OPERATOR HAS AN EXTERNAL RADIO RECEIVER, DISCONNECT POWER TO IT 2. IF THE OPERATOR HAS A BUILT-IN RADIO RECEIVER, CUT THE COMPONENT THAT FEEDS POWER TO THE RECEIVER OPERATOR'S OR CUT OFF THE OPERATOR'S ANTENNA AND REMOVE THE ANTENNA RECEIVER'S TUNING SLUG NOTE: IT IS RECOMMENDED TO DISABLE THE OPERATOR'S RECEIVER TO PREVENT THE OLD REMOTES FROM ACTIVATING IT LINEAR LIMITED WARRANTY

IMPORTANT SAFETY INSTRUCTIONS

This symbol is intended to alert the user to the presence of

un-insulated “dangerous voltage” within the product’s enclosure that

may be of suffi cient magnitude to constitute a risk of electric shock.

✶ WARNING! To reduce the risk of fi re or electric shock, do not

This symbol is intended to alert the user to the presence of

important operating and maintenance (Servicing) instructions in the

IS NOT CONTROLLED BY A WALL SWITCH

LEARN & SIGNAL

INDICATOR

BUTTON

NOTE: BE SURE THAT THE OUTLET

EXPLANATION OF GRAPHIC WARNING SYMBOLS

LEARN

expose this device to rain, water, or wet locations.

RISK OF ELECTRICAL SHOCK

1 AMP @ 32 VDC MAXIMUM

RECEIVER INTO THE 110 VAC OUTLET

DO NOT OPEN

RELAY OUTPUT

TERMINALS

CAUTION

literature accompanying the device.

REMOVE THE OUTLET'S COVER

PLATE SCREW AND PLUG THE

AC POWER

SECURE THE RECEIVER

THE RETAINING SCREW

TO THE OUTLET WITH

RETAINING

SCREW

ANTENNA

The Model MDR-U Universal MegaCode™ Receiver is designed for use as a

replacement radio control receiver in garage door operator installations. The

receiver is self-contained, not requiring an external transformer or power from the

garage door operator. The receiver plugs directly into a 120 VAC outlet. A retaining

Two screw terminals on the receiver are for connection to the garage operator’s

pushbutton input. A dry contact, Form “A”, relay in the receiver will provide a

.5-seconds closure across the terminals when the receiver activates. A fl exible wire

MegaCode™ receivers and transmitters do not contain a typical “coding switch”.

Each transmitter is pre-set at the factory to a unique code. The receiver is

programmed by sending a signal from the transmitter, storing the transmitter’s code

into the receiver’s memory. The receiver will retain its memory, even without power.

The receiver will activate only from these “memorized” transmitters. Each MDR-U

The learn button and learn indicator are used for entering and erasing the

transmitters in the receiver’s memory. The learn indicator also displays signals

TYPE CL2, CL2P, CL2R, OR CL2X OR OTHER CABLE

PUSHBUTTON

MDR-U

antenna extends from the receiver’s case to provide maximum radio reception.

receiver can be programmed to activate from up to ten MegaCode™ transmitters.

DISCONNECT POWER TO THE GARAGE

DOOR OPERATOR BEFORE PROCEEDING

USED WITH THE OPERATOR MUST BE UL LISTED

ANTENNA

UL NOTE: ALL LOW VOLTAGE CLASS 2 CABLE

WITH EQUIVALENT OR BETTER ELECTRICAL,

MECHANICAL, AND FLAMMABILITY RATINGS

OPERATOR

FROM

WALL PUSHBUTTON

CONNECTION

USA & Canada (800) 421-1587 & (800) 392-0123

(760) 438-7000 • FAX (760) 438-7043

screw is provided to secure the receiver to the outlet.

being received and can be used for troubleshooting.

Toll Free FAX (800) 468-1340

SECURE THE

THE WALL PUSHBUTTON USES)

www.linearcorp.com

WIRE WITH

INSULATED

STAPLES

OPERATOR TERMINALS 1 & 2

(OR THE SAME TERMINALS

Installation Instructions

TO EITHER THE WALL PUSHBUTTON OR

DIRECTLY TO THE DOOR OPERATOR

ROUTE THE WIRE AND CONNECT IT

MDR-U RECEIVER RELAY OUTPUT TERMINALS

PRODUCT DESCRIPTION

(POLARITY NOT IMPORTANT)

For Garage Door Operator

CONNECT 2-CONDUCTOR WIRE TO THE

MegaCode ™

DIRECT OPERATOR

MDR-U

CONNECTION

Universal

Receiver

Remote Control

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Linear MDR-U

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Linear MDR-U

Be the first to ask — other owners or our team will answer.

Original document

Linear MDR-U manual PDF

1 pages·174 KB·Garage Door Opener·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…