Page 1
IMPORTANT SAFETY INSTRUCTIONS
MDR-U Universal MegaCode™ Receiver For Garage Door Operator Remote Control Installation Instructions (760) 438-7000 • FAX (760) 438-7043 USA & Canada (800) 421-1587 & (800) 392-0123 Toll Free FAX (800) 468-1340 www.linearcorp.com PRODUCT DESCRIPTIONCAUTION RISK OF ELECTRICAL SHOCK DO NOT OPEN EXPLANATION OF GRAPHIC WARNING SYMBOLS This symbol is intended to alert the user to the presence of un-insulated “dangerous voltage” within the product’s enclosure that may be of suffi cient magnitude to constitute a risk of electric shock. ✶ WARNING! To reduce the risk of fi re or electric shock, do not expose this device to rain, water, or wet locations. This symbol is intended to alert the user to the presence of important operating and maintenance (Servicing) instructions in the literature accompanying the device. COMPONENT LOCATIONSIMPORTANT SAFETY INSTRUCTIONS WARNING TO REDUCE THE RISK OF SEVERE INJURY OR DEATH 1. READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS 2. NEVER LET CHILDREN OPERATE, OR PLAY WITH DOOR CONTROLS! KEEP REMOTE CONTROL AWAY FROM CHILDREN! 3. ALWAYS KEEP MOVING DOOR IN SIGHT AND AWAY FROM PEOPLE AND OBJECTS UNTIL IT IS COMPLETELY CLOSED. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR. 4. NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR. CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK, DISCONNECT POWER TO THE RECEPTACLE BEFORE INSTALLING OR REMOVING THE UNIT. WHEN REMOVING RECEPTACLE COVER SCREW, COVER MAY FALL ACROSS PLUG PINS OR RECEPTACLE MAY BECOME DISPLACED. USE ONLY WITH DUPLEX RECEPTACLE HAVING CENTER SCREW. SECURE UNIT IN PLACE BY RECEPTACLE COVER SCREW. DETERMINE THE BEST RECEIVER LOCATIONIMPORTANT SAFETY INSTRUCTIONS 1. Read these instructions. 2. Keep these instructions. 3. Heed all warnings. 4. Follow all instructions 5. Do not use this apparatus near water. 6. Clean only with dry cloth. 7. Do not install near any heat sources such as radiators, heat registers, stoves, or other apparatus (including amplifi ers) that produce heat. 8. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fi t into your outlet, consult an electrician for replacement of the obsolete outlet. 9. Unplug this apparatus during lightning storms or when unused for long periods of time. 10. Refer all servicing to qualifi ed service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped. CHECK FOR INTERFERENCE FROM OTHER RECEIVERS
The Model MDR-U Universal MegaCode™ Receiver is designed for use as a replacement radio control receiver in garage door operator installations. The receiver is self-contained, not requiring an external transformer or power from the garage door operator. The receiver plugs directly into a 120 VAC outlet. A retaining screw is provided to secure the receiver to the outlet. Two screw terminals on the receiver are for connection to the garage operator’s pushbutton input. A dry contact, Form “A”, relay in the receiver will provide a .5-seconds closure across the terminals when the receiver activates. A fl exible wire antenna extends from the receiver’s case to provide maximum radio reception. MegaCode™ receivers and transmitters do not contain a typical “coding switch”. Each transmitter is pre-set at the factory to a unique code. The receiver is programmed by sending a signal from the transmitter, storing the transmitter’s code into the receiver’s memory. The receiver will retain its memory, even without power. The receiver will activate only from these “memorized” transmitters. Each MDR-U receiver can be programmed to activate from up to ten MegaCode™ transmitters. The learn button and learn indicator are used for entering and erasing the transmitters in the receiver’s memory. The learn indicator also displays signals being received and can be used for troubleshooting. CONNECT THE RECEIVER TO THE OPERATORAC POWER RETAINING TERMINALS LEARN & SIGNAL SCREW INDICATOR ANTENNA RELAY OUTPUT LEARN TERMINALS BUTTON 1 AMP @ 32 VDC MAXIMUM INSTALL THE RECEIVERBEST RECEPTION A PLUG ON THE CEILING WILL GIVE THE BEST RADIO RECEPTION (UNLESS THE OPERATOR'S RECEIVER CAUSES SOME INTERFERENCE) GOOD RECEPTION A PLUG ABOVE A PLUG CLOSE THE GROUND LEVEL TO GROUND LEVEL WILL PROVIDE POOR WILL CAUSE GOOD RADIO RECEPTION POOR RADIO RECEPTION RECEPTION PROGRAM AND TEST THE RECEIVERWATCH THE MDR-U RECEIVER'S IF THE LEARN INDICATOR IS FLASHING WITHOUT ACTIVATING ANY TRANSMITTERS, LEARN INDICATOR INTERFERENCE MAY BE COMING FROM A NEARBY OPERATOR'S RECEIVER TEST IF THE OPERATOR IS THE SOURCE OF THE INTERFERENCE BY UN-PLUGGING THE OPERATOR FROM POWER IF THE LEARN INDICATOR STOPS FLASHING, THE OPERATOR IS THE SOURCE OF INTERFERENCE 1. IF THE OPERATOR HAS AN EXTERNAL RADIO RECEIVER, DISCONNECT POWER TO IT 2. IF THE OPERATOR HAS A BUILT-IN RADIO RECEIVER, CUT THE COMPONENT THAT FEEDS POWER TO THE RECEIVER OPERATOR'S OR CUT OFF THE OPERATOR'S ANTENNA AND REMOVE THE ANTENNA RECEIVER'S TUNING SLUG NOTE: IT IS RECOMMENDED TO DISABLE THE OPERATOR'S RECEIVER TO PREVENT THE OLD REMOTES FROM ACTIVATING IT LINEAR LIMITED WARRANTY
IMPORTANT SAFETY INSTRUCTIONS
This symbol is intended to alert the user to the presence of
un-insulated “dangerous voltage” within the product’s enclosure that
may be of suffi cient magnitude to constitute a risk of electric shock.
✶ WARNING! To reduce the risk of fi re or electric shock, do not
This symbol is intended to alert the user to the presence of
important operating and maintenance (Servicing) instructions in the
IS NOT CONTROLLED BY A WALL SWITCH
LEARN & SIGNAL
INDICATOR
BUTTON
NOTE: BE SURE THAT THE OUTLET
EXPLANATION OF GRAPHIC WARNING SYMBOLS
LEARN
expose this device to rain, water, or wet locations.
RISK OF ELECTRICAL SHOCK
1 AMP @ 32 VDC MAXIMUM
RECEIVER INTO THE 110 VAC OUTLET
DO NOT OPEN
RELAY OUTPUT
TERMINALS
CAUTION
literature accompanying the device.
REMOVE THE OUTLET'S COVER
PLATE SCREW AND PLUG THE
AC POWER
SECURE THE RECEIVER
THE RETAINING SCREW
TO THE OUTLET WITH
RETAINING
SCREW
ANTENNA
The Model MDR-U Universal MegaCode™ Receiver is designed for use as a
replacement radio control receiver in garage door operator installations. The
receiver is self-contained, not requiring an external transformer or power from the
garage door operator. The receiver plugs directly into a 120 VAC outlet. A retaining
Two screw terminals on the receiver are for connection to the garage operator’s
pushbutton input. A dry contact, Form “A”, relay in the receiver will provide a
.5-seconds closure across the terminals when the receiver activates. A fl exible wire
MegaCode™ receivers and transmitters do not contain a typical “coding switch”.
Each transmitter is pre-set at the factory to a unique code. The receiver is
programmed by sending a signal from the transmitter, storing the transmitter’s code
into the receiver’s memory. The receiver will retain its memory, even without power.
The receiver will activate only from these “memorized” transmitters. Each MDR-U
The learn button and learn indicator are used for entering and erasing the
transmitters in the receiver’s memory. The learn indicator also displays signals
TYPE CL2, CL2P, CL2R, OR CL2X OR OTHER CABLE
PUSHBUTTON
MDR-U
antenna extends from the receiver’s case to provide maximum radio reception.
receiver can be programmed to activate from up to ten MegaCode™ transmitters.
DISCONNECT POWER TO THE GARAGE
DOOR OPERATOR BEFORE PROCEEDING
USED WITH THE OPERATOR MUST BE UL LISTED
ANTENNA
UL NOTE: ALL LOW VOLTAGE CLASS 2 CABLE
WITH EQUIVALENT OR BETTER ELECTRICAL,
MECHANICAL, AND FLAMMABILITY RATINGS
OPERATOR
FROM
WALL PUSHBUTTON
CONNECTION
USA & Canada (800) 421-1587 & (800) 392-0123
(760) 438-7000 • FAX (760) 438-7043
screw is provided to secure the receiver to the outlet.
being received and can be used for troubleshooting.
Toll Free FAX (800) 468-1340
SECURE THE
THE WALL PUSHBUTTON USES)
www.linearcorp.com
WIRE WITH
INSULATED
STAPLES
OPERATOR TERMINALS 1 & 2
(OR THE SAME TERMINALS
Installation Instructions
TO EITHER THE WALL PUSHBUTTON OR
DIRECTLY TO THE DOOR OPERATOR
ROUTE THE WIRE AND CONNECT IT
MDR-U RECEIVER RELAY OUTPUT TERMINALS
PRODUCT DESCRIPTION
(POLARITY NOT IMPORTANT)
For Garage Door Operator
CONNECT 2-CONDUCTOR WIRE TO THE
MegaCode ™
DIRECT OPERATOR
MDR-U
CONNECTION
Universal
Receiver
Remote Control