EN
Linear logo
Official user manual

Linear LDCO800

2 pages·1.1 MB·Garage Door Opener·PDF·ENDEFRITNLJA
Linear LDCO800
Table of Contents 80 sections 7 Install the Wall Station · MARKING THE CENTERLINE · MODEL LDCO800 BELT-DRIVE OR CHAIN-DRIVE DC MOTOR GARAGE DOOR OPERATOR · INSTALLATION INSTRUCTIONS · … ShowHide
7 Install the Wall Stationp.1MARKING THE CENTERLINEp.1MODEL LDCO800 BELT-DRIVE OR CHAIN-DRIVE DC MOTOR GARAGE DOOR OPERATORp.1INSTALLATION INSTRUCTIONSp.1CONNECTING AND LOCATING THE WALL STATIONp.1For Sectional Type Doors IMPORTANT SAFETY NOTESp.1CONNECT PUSHBUTTON WIRES TO WALL STATION'S TERMINALSp.1MARKING ABOVE THE HIGH-RISE POINTp.1MARK HEADER 1" ABOVEp.1HIGH-RISE POINTp.1THE FOLLOWING FORMATS ARE USED FORp.1DOORp.1MOUNTING THE WALL STATIONp.1USE WOOD SCREWS WHEN MOUNTING DIRECTLY TO WALLp.1ROUTE WIRE THROUGH SLOT IN CASEp.1ATTACHING THE HEADER BRACKETp.11/2" SOCKETp.1CENTERLINE OF DOORp.1PUT HOLE PLUGS IN TO HIDE SCREWSp.1IMPORTANT INSTALLATION SAFETY INSTRUCTIONSp.11 INCHp.1CONNECTING THE WIRES TO OPERATORp.1HIGH-RISE POINT OF DOORp.1THESE INSTALLATION SAFETY STEPS BEFORE PROCEEDINGp.1WIRES TO WALL STATIONp.1ATTACHING THE HEADER BRACKET TO THE CEILINGp.1NO MORE THAN 6 INCHESp.1PUSHBUTTONp.1COMMONp.18 Install the Safety Beamp.1ASSEMBLING THE BRACKETSp.1DOOR HEADER WALLp.1FOR LOW HEADROOM DOOR INSTALLATIONS ONLYp.110 Connect the Operator to Power Sourcep.1MARKING THE CORRECT BEAM BRACKET HEIGHTp.1POWERING THE OPERATORp.1CHECKING THE DOOR BALANCEp.1CEILING OUTLETp.1PLUG OPERATOR INTO GROUNDED OUTLETp.1INSTALLING THE BEAMSp.1ALIGNING THE RAILp.1FOR PERMANENT WIRING ONLY!p.1INSERT UNIT INTO BRACKETp.1REMOVING THE POWER CORDp.1TWIST UNIT TO LOCK INTO BRACKETp.1BE SURE THE POWER CORD IS UNPLUGGED!!p.1ADJUSTING OPERATOR HEIGHTp.1CHAIN DRIVE BELT DRIVEp.1PRE-ADJUSTING THE BEAMSp.1ADJUST UNITS SO LENSES POINT TOWARD EACH OTHERp.1MATING THE SPROCKET AND SHAFTp.1SLIDE THE SPROCKET INTO THE SHAFTp.1ADJUST HEIGHT AS REQUIREDp.1REMOVING THE BUSHINGp.1HANGING BRACKET OPTIONSp.1TABS FIT INTO SLOTSp.1CONNECTING THE BEAM WIRESp.1REMOVE STRAIN RELIEF BUSHING WITH PLIERSp.1TYPICAL HANGING BRACKETS SCREWED DIRECTLY TO JOISTSp.1ATTACHING THE RAILp.1PUSHBUTTON WIRESp.1BEAM WIRESp.1TYPICAL HANGING BRACKET ASSEMBLY USING A CROSSPIECEp.1BEAMSp.1TIGHTEN THE RAIL-TO-HEAD BOLTS IN THIS ORDERp.1HANGING THE OPERATORp.1HARDWIRING THE OPERATORp.1CONDUIT WIRE NUTSp.117 Using the Garage Door Operatorp.2IMPORTANT USER SAFETY INSTRUCTIONSp.2WARNING A MOVING GARAGE DOOR CAN CAUSE INJURY OR DEATH!p.2TO REDUCE THE RISK OF DEATH OR SEVERE INJURY:p.2ADJUSTING THE OPEN LIMITp.2DOWN UPp.2SAFETY BEAM INDICATORSp.2EXAMINE THE SPOT WHERE THE DOOR OPENSp.2RED LIGHTp.2TO DISCONNECT OPERATORp.2TO RECONNECT OPERATORp.2ADJUSTING THE CLOSE LIMITp.2
Page 1 of the Linear LDCO800 user manual — FOR PERMANENT WIRING ONLY!
Page 1 · click to enlarge
Page 1
Linear LDCO800 — 7 Install the Wall Station diagram (page 1)
Fig. 1 · 7 Install the Wall Station

LINEAR LLC (760) 438-7000 USA & Canada (800) 835-5666 & (800) 421-1587

3 Locate the Header Bracket Position 1 Close the door. 2 From inside the garage, use a pencil to mark the vertical centerline of the door on the header wall and on the top panel of the door. 3 Examine the area above the center of the door on the door header wall for a header bracket mounting location. 4 Open the door to the high-rise point (the point where the top edge of the door is highest above the floor) and measure the distance to the floor. 5 Close the door and use a pencil to mark the header wall 1” above the measured high-rise point. NOTE: In some installations, the header bracket

7 Install the Wall Station

9 Install the Door Bracket and Door Arm 1 Fully close the door. Hold the door bracket against the inside of the door’s top panel. Align the top edge of the bracket 2” to 4” below the top edge of the door; or, if there is a structural support across the top of the door, place the top edge of the bracket directly below the support. Align the vertical centerline drawn on the door with the center of the bracket. See the figure for details. Mark the left and right holes of the bracket. 2 Drill ¼” holes at marks and insert two ¼-20 x 2” carriage bolts (not supplied) from outside of door through the door bracket. 3 Secure door bracket with two ¼-20 keps nuts (not supplied). Tighten with a 7/16” socket. 4 Slide the 5/16” x 1-3/8” clevis pin through one hole on door bracket; then the single hole on the curved door arm; then through the other hole on the door bracket. Secure the clevis pin with the hitch pin. 5 Insert the single hole end of the straight door arm into the slot in the trolley. Slide the 1-1/8” clevis pin through the hole and secure it with a hitch pin. 6 Flip the trolley release lever to disconnect the trolley. 7 Rotate the curved door arm upward to meet the straight door arm connected to the trolley. Align the two door arms so that the holes in both arms overlap. NOTE: The straight door arm should be slightly angled

WARNING Children operating or playing with a garage door operator can injure themselves or others. The garage door could cause serious injury or death. Do not allow children to operate the remote control(s) or the wall station. Install the wall station out of reach of children and away from all moving parts of the door. The door must be clearly visible from the wall station. A moving garage door could injure someone under it. Only activate the door when it is properly adjusted, when it can be seen clearly and when there are no obstructions to the door travel.

MARKING THE CENTERLINE

MARK THE CENTERLINE OF THE DOOR ON THE HEADER AND THE TOP DOOR PANEL

Linear LDCO800 — MARKING THE CENTERLINE diagram (page 1)
Fig. 2

Toll Free FAX (800) 468-1340

www.linearcorp.com

MODEL LDCO800 BELT-DRIVE OR CHAIN-DRIVE DC MOTOR GARAGE DOOR OPERATOR

ALIGN THE DOOR BRACKET ON THE CENTERLINE 2" TO 4"

BELOW THE TOP EDGE OF THE DOOR, OR DIRECTLY

INSTALLATION INSTRUCTIONS

BELOW ANY DOOR STRUCTURAL SUPPORT DRILL TWO 1/4" PILOT HOLES USE TWO 1/4-20 x 2" CARRIAGE BOLTS AND NUTS (NOT SUPPLIED) TO ATTACH THE DOOR BRACKET

CONNECTING AND LOCATING THE WALL STATION

For Sectional Type Doors IMPORTANT SAFETY NOTES

beam wire is supplied with the operator, Use this wire or the installation’s pre-wiring. For additional wire, contact Linear for information regarding the 24-pack Model HAE00009 wire and wire clip kit. UL NOTE: All low voltage Class 2 cable used with this

CONNECT PUSHBUTTON WIRES TO WALL STATION'S TERMINALS

MARKING ABOVE THE HIGH-RISE POINT

location will be higher than the door header. This will require adding a 2x4 (or larger) cross piece to the wall studs to provide a mounting location for the header bracket. Use lag screws (not supplied) to attach the 2x4 to the studs. 6 On doors with low headroom, the header bracket can be attached to the ceiling up to 6” back from the header wall (see next step).

MARK HEADER 1" ABOVE

HIGH-RISE POINT

Please read the instructions carefully! This garage door operator is designed to provide safe and reliable service if installed and tested as described in these instructions. A garage door is the largest mechanical appliance in a residence. Care must be taken to prevent injury or death during installation and operation of the garage door and garage door operator.

THE FOLLOWING FORMATS ARE USED FOR

SAFETY NOTES IN THESE INSTRUCTIONS.

operator must be UL Listed Type CL2, CL2P, CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and flammability ratings. 1 Strip back ½” of insulation and connect a wire to each of the two terminals on the back of the wall station. 2 Use the screws provided to mount the wall station near an access door at a minimum height of five feet. SEE IMPORTANT WARNING ABOVE! 3 For non-prewired installations, route the wire to the back of the operator. Use insulated staples (not supplied) to secure the wire. Staples must straddle both wires to avoid electrical shorts. 4 Cut the wall station wire about 6” longer than needed to reach the operator terminals. Strip back ½” of insulation. 5 Connect either wire to the operator’s PUSHBUTTON terminal and the other wire to the operator’s COMMON terminal. 6 Apply the User Safety Instruction Label to the wall next to the wall station. Use staples or tacks to help the label remain in place over time. IMPORTANT! DO NOT PLUG THE OPERATOR IN AT

MOUNT WALL STATION AT LEAST 5 FEET ABOVE THE FLOOR LEVEL

DOOR

MOUNTING THE WALL STATION

USE MACHINE SCREWS WHEN MOUNTING TO A SINGLE-GANG BOX

USE WOOD SCREWS WHEN MOUNTING DIRECTLY TO WALL

4 Install the Header Bracket Attaching the Header Bracket to the Wall 1 Hold the header bracket on the center line drawn above the door with the bottom edge of the bracket on the line marked above the high-rise point. 2 Use a pencil to mark the two bracket holes. 3 Drill two 3/16” pilot holes about 2” deep. 4 Use a ½” socket to fasten the bracket with two 5/16” x 2” lag screws. Attaching the Header Bracket to the Ceiling NOTE: On a finished ceiling, be sure there is a joist

ROUTE WIRE THROUGH SLOT IN CASE

ATTACHING THE HEADER BRACKET

1/2" SOCKET

CENTERLINE OF DOOR

PUT HOLE PLUGS IN TO HIDE SCREWS

toward the operator head. CONNECTING DOOR ARMS 1 Line up door arms until trolley is positioned as shown. Connect the arms together using two 5/16-18 x 1” bolts inserted in the highest and lowest matching holes, secure the bolts with two 5/16” keps nuts, tighten with a ½” socket.

IMPORTANT INSTALLATION SAFETY INSTRUCTIONS

ATTACH HEADER BRACKET WITH TWO 5/16" x 2" LAG SCREWS

1 INCH

CONNECTING THE WIRES TO OPERATOR

CONNECT WALL STATION WIRES TO PUSHBUTTON AND COMMON TERMINALS (EITHER WIRE TO EITHER TERMINAL)

HIGH-RISE POINT OF DOOR

THESE INSTALLATION SAFETY STEPS BEFORE PROCEEDING

WIRES TO WALL STATION

to fasten to under the sheetrock where the header bracket will be located (use a stud finder). If there is none, install a 2x4 cross piece between the two closest joists to fasten the header bracket onto. 1 Extend the center line drawn on the header wall along the ceiling. 2 Hold the bracket on the center line with the edge of the bracket no further than 6” from the header wall. 3 Use a pencil to mark the two bracket holes. 4 Drill two 3/16” pilot holes about 2” deep. 5 Use a ½” socket to fasten the bracket with two 5/16” x 2” lag screws.

1 READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS. 2 Install only on a properly balanced garage door. An improperly balanced door could result in severe injury or death. Repairs to cables, spring assemblies, and other hardware must be made by a qualified service person before installing the operator. 3 Use this operator only with sectional overhead doors no more than 10 ft. tall. 4 Disable all locks and remove all ropes connected to the garage door before installing the operator. Ropes connected to a garage door can cause entanglement and death. 5 If possible, install door operator 7 feet or more above the floor with the manual release handle mounted 6 feet above the floor. 6 Do not connect the operator to the power source until instructed to do so. 7 Locate the wall station within sight of the door at a minimum height of 5 feet so that small children cannot reach it. Locate the wall station away from all moving parts of the door. 8 Install the User Safety Label on the wall adjacent to the wall station. 9 Upon completion of the installation, the door must reverse when it comes in contact with a 1-1/2” high object (or a 2x4 laid flat at the center of the door) on the floor and when the infrared safety beam is blocked. 10 Do not wear watches, rings or loose clothing while installing or servicing an operator. Jewelry or loose clothing can be caught in the mechanism of the garage door or the operator. 11 DISCONNECT THE ELECTRIC POWER FROM THE GARAGE DOOR OPERATOR BEFORE MAKING ANY REPAIRS OR REMOVING THE COVER.

ATTACHING THE HEADER BRACKET TO THE CEILING

NO MORE THAN 6 INCHES

THIS TIME! More installation is required.

LINE UP DOOR ARMS UNTIL TROLLEY IS POSITIONED AS SHOWN

PUSHBUTTON

COMMON

CENTERLINE OF DOOR

8 Install the Safety Beam

ASSEMBLING THE BRACKETS

DOOR HEADER WALL

ASSEMBLE BRACKETS WITH 1/4-20 x 3/4" BOLTS AND KEPS NUTS

FOR LOW HEADROOM DOOR INSTALLATIONS ONLY

10 Connect the Operator to Power Source

5 Connect the Rail to the Header Bracket 1 Place assembled operator on the empty carton on the floor with rail towards the door. 2 Insert the end of the rail into header bracket. 3 Insert the 5/16” x 2-3/8” clevis pin through header bracket and rail. 4 Secure the clevis pin with the hitch pin.

Linear LDCO800 — FOR LOW HEADROOM DOOR INSTALLATIONS ONLY diagram (page 1)
Fig. 3

not be obstructed by the door, or by any part of the door hardware. Use wooden spacers between the beam brackets and wall if necessary to create proper clearance. 1 Assemble the two safety beam brackets from the four L-shaped brackets using two ¼-20 x ¾” bolts and ¼‑20 keps nuts (one nut & bolt for each bracket).

Cord and Outlet Connection The operator should be connected to a grounded receptacle on the ceiling or near the operator head. If none is available which will accept the grounded operator plug, one should be installed by a qualified electrician. Do not use an extension cord. 1 Plug the operator into a grounded receptacle. 2 When the operator is plugged in, a click should sound in the operator and the light should turn on. If light does not turn on, check the power source and light bulb.

MARKING THE CORRECT BEAM BRACKET HEIGHT

1 Check the Door Balance 1 From outside the garage, slowly open the door all the way, and then close it all the way. Notice if there is any binding, sticking or rubbing. The door should move smoothly in both directions. 2 Raise the garage door about halfway up. Carefully release the door and see if the door balances. It should stay in place. Close the door. IMPORTANT: If the garage door is unbalanced or

POWERING THE OPERATOR

CHECKING THE DOOR BALANCE

6 Hang the Operator Installation requirements vary with garage construction. Hanging brackets should be angled to provide rigid support. Hanging material is not provided. Angle iron and lag screws are recommended. DO NOT USE NAILS. Following are typical operator hanging methods. Certain installations will require improvised methods. 1 Raise the operator head and set it on top of a stepladder (use extra spacers on top of ladder if it isn’t tall enough). 2 Carefully open the door to the full up position. Lay a 2x4 across the top section of the door as a spacer. Adjust the operator height until the rail touches the spacer. The rail should be close to level. 3 Center the operator head and rail with the centerline mark on the top of the door. 4 For finished ceilings only: An angle iron cross piece between the two closest joists above the operator will be required. Mark mounting hole locations, drill pilot holes and attach the piece with two lag screws (not supplied). 5 Measure the distance from each of the operator’s hanging tabs to the ceiling joists or angle iron cross piece. 6 Cut two angle iron pieces to the required lengths for hanging brackets. Bend brackets if required. • For unfinished ceilings: Hold each bracket in place

CEILING OUTLET

LOCATE THE SAFETY BEAM BRACKETS SO THE BEAM CENTERLINE IS 5-1/2" ABOVE THE FLOOR

2 Position the assembled brackets on each side of the door so the center line of the safety beam lenses will be 5-1/2” above the floor. Use the index marks on the brackets to make the bracket assemblies equal lengths. Mark the locations for the bracket mounting screws. NOTE: The safety beam receiver (the unit with two

PLUG OPERATOR INTO GROUNDED OUTLET

THE DOOR SHOULD BALANCE WITHOUT GOING UP OR DOWN

INSTALLING THE BEAMS

the door travel isn’t smooth, have a qualified garage door professional adjust or repair the door.

indicators) should be located on the “shady” side of the door to prevent sunlight from shining directly into the receiver’s lens. 3 Drill two 3/16” pilot holes for lag screws at marks. Mount the brackets with two ¼” x 1-¼” lag screws and tighten with a 7/16” socket. 4 Insert the sender and receiver into the bracket holes so the lenses of the units will face each other. Twist the units until the spring clips lock into a detent mark on the brackets. To protect the units from being bumped after installation, it is recommended to mount the sender and receiver inside the brackets as shown. IMPORTANT: Be careful to route the safety beam wiring

2 Attach the Rail to the Operator 1 Place the operator head on the garage floor with cardboard underneath it to protect the finish. 2 Align the rail over the center of the operator head. 3 Be sure the flat on the sprocket lines up with the flat on the drive shaft. 4 Slide the sprocket onto the shaft. 5 Attach the rail to the operator head by installing four ¼-20 x ¾” bolts. 6 Tighten the four bolts in the order shown with a 7/16” socket.

ALIGNING THE RAIL

LINE UP THE RAIL OVER THE DRIVE SHAFT ON TOP OF THE OPERATOR HEAD

Permanent Wiring SOME LOCAL ELECTRICAL CODES REQUIRE PERMANENT WIRING BETWEEN THE OPERATOR AND THE POWER SOURCE THROUGH A CONDUIT. IT IS RECOMMENDED THAT YOU HAVE A LICENSED ELECTRICAL CONTRACTOR FOLLOW THESE STEPS ONLY IF PERMANENT WIRING IS REQUIRED.

FOR PERMANENT WIRING ONLY!

INSERT UNIT INTO BRACKET

REMOVING THE POWER CORD

TWIST UNIT TO LOCK INTO BRACKET

BE SURE THE POWER CORD IS UNPLUGGED!!

ADJUSTING OPERATOR HEIGHT

PLACE A 2x4 SPACER BETWEEN THE DOOR AND RAIL

CHAIN DRIVE BELT DRIVE

PRE-ADJUSTING THE BEAMS

BE SURE THE FLAT ON THE SPROCKET LINES UP WITH THE FLAT ON THE DRIVE SHAFT

1 BE SURE POWER CORD IS UNPLUGGED. 2 Cut the power cord about 2” above the strain relief bushing on the operator. 3 Remove the four side screws and bottom cover of operator. 4 Use pliers to remove the strain relief bushing and discard the bushing. 5 Remove the outer insulation from the power cord and strip the white, black, and green wire insulation back about ½”. 6 Pull white (neutral), black (hot) and green (ground) wires through conduit. 7 Connect the conduit to the operator with the appropriate termination. 8 Use wire nuts (not supplied) to connect the wires to the matching color wires inside operator head. 9 Secure the wires away from all moving parts with a zip-tie as shown in the figure. 10 Replace the operator cover and the four side screws. 11 Connect the conduit wires to the power source at junction box. 12 When power is applied to the operator, a click should sound and the light should turn on. If the light does not turn on, check the power source, wiring, and light bulb.

CUT THE CORD ABOUT 2" ABOVE THE STRAIN RELIEF BUSHING

ADJUST UNITS SO LENSES POINT TOWARD EACH OTHER

DOOR

MATING THE SPROCKET AND SHAFT

SLIDE THE SPROCKET INTO THE SHAFT

away from any moving parts of the door or operator. 5 For non-prewired installations, route the wires from the sender and receiver, up the wall above the door hardware, then over to the center of the door, then along the top of the rail (or ceiling), and back to the operator head. Cut the wires about 6” longer than needed to reach the operator terminals. Strip back ½” of insulation from the ends of the wires. 6 For non-prewired installations, secure all the wires to the wall and ceiling with insulated staples (not supplied). Staples must straddle both wires to prevent shorts. Secure the wire to the top of the rail with wire clips (supplied). 7 At the operator, twist one wire from each pair together, then twist the other wire from each pair together. 8 Attach either twisted connection to the operator’s BEAM terminal. Connect the other twisted connection to the operator’s COMMON terminal.

ADJUST HEIGHT AS REQUIRED

and use a pencil to mark the locations where they will be attached to the joists, drill pilot holes and attach the pieces with two lag screws (not supplied). • For finished ceilings with an angle iron cross piece:

SPRING CLIP LATCHES INTO DETENT MARKS TO HOLD UNIT'S POSITION

FOR PERMANENT WIRING ONLY!

REMOVING THE BUSHING

Attach the two hanging brackets to the cross piece with two bolts and two keps nuts (not supplied). 7 Attach operator to hanging brackets using two 5/16-18 x 1” hex bolts and two 5/16-18 keps nuts (supplied). Insert bolts from the inside of hanger brackets with the nuts on the outside of the operator. Tighten nuts with a ½” socket. 8 Tighten all hanging hardware. 9 Open and close the door manually. The door should clear the rail by at least 1”. 10 Attach the trolley’s release lever to the red release handle with the cord supplied so the handle is at least 6 feet from the floor. Cut off any excess cord. 11 Remove the light cover to access the lamp socket. Install a 100 watt maximum rough service in the lamp socket. Reattach the light cover.

HANGING BRACKET OPTIONS

CHAIN DRIVE BELT DRIVE

TABS FIT INTO SLOTS

CONNECTING THE BEAM WIRES

REMOVE STRAIN RELIEF BUSHING WITH PLIERS

TYPICAL HANGING BRACKETS SCREWED DIRECTLY TO JOISTS

CONNECT SAFETY BEAM WIRES TO COMMON AND BEAM TERMINALS (EITHER WIRE TO EITHER TERMINAL)

ATTACHING THE RAIL

PUSHBUTTON WIRES

BEAM WIRES

INSTALL FOUR 1/4-20 x 3/4" RAIL-TO-HEAD BOLTS USING A 7/16" SOCKET

TYPICAL HANGING BRACKET ASSEMBLY USING A CROSSPIECE

PUSHBUTTON

COMMON

BEAMS

PULL THE CHAIN OR BELT AWAY FROM THE RAIL TO FIT THE SOCKET ON THE FRONT BOLTS

FOR PERMANENT WIRING ONLY!

TIGHTEN THE RAIL-TO-HEAD BOLTS IN THIS ORDER

HANGING THE OPERATOR

HARDWIRING THE OPERATOR

CONDUIT WIRE NUTS

HANG OPERATOR WITH TWO 5/16-18 x 1" BOLTS AND NUTS

CONNECT CONDUIT WIRING TO OPERATOR WIRING WITH WIRE NUTS

GREEN - GROUND WHITE - NEUTRAL BLACK - HOT

Page 2 of the Linear LDCO800 user manual — IF DOOR BECOMES OBSTRUCTED,
Page 2 · click to enlarge
Page 2

11 Aligning the Infrared Safety Beam The safety beam has two components, a sender and a receiver. The sender produces a narrow infrared beam that travels across the bottom of the door opening to the infrared receiver. If an object blocks the infrared beam while the door is closing, the door will stop, then reverse and fully open (the operator’s light will flash three times). As a safety feature, the operator will ignore signals from all remote controls if the door is open and the infrared safety beam is blocked or out of alignment. In this case, the door can be forced closed by pressing and holding the wall station’s up/down arrow pushbutton (be sure the door area is in clear view).

13 Adjusting the Open and Close Limits The limit settings control how far the door will open and close. Set the limits so the door opens just short of any door stops, and closes at the floor level. Out of the box, the operator is preset on its close limit and the open limit is preset for a 7-foot high door. Use the wall station or a transmitter to test operate the door. If required, use the following steps to adjust the limits. Adjusting the Open Limit 1 Use the wall station or a transmitter to move the door to the open limit position. 2 Press both the UP and LEARN buttons for three seconds. The green indicator and operator’s light will flash twice then stay on. 3 If necessary, use the UP and DOWN buttons to jog the door at slow speed to fine-tune the open limit position. 4 When the door is at the proper open limit position, press the LEARN button to store the setting and exit setup. The green indicator and the operator’s light will flash two times. Adjusting the Close Limit 1 Use the wall station or a transmitter to move the door to the close limit position. 2 Press both the DOWN and LEARN buttons for three seconds. The red indicator and operator’s light will flash twice then stay on. 3 If necessary, use the UP and DOWN buttons to jog the door at slow speed to fine-tune the close limit position. 4 When the door is at the proper close limit position, press the LEARN button to store the setting and exit setup. The red indicator and the operator’s light will flash two times.

17 Using the Garage Door Operator

18 Garage Door Operator Maintenance Weather conditions may affect the door operation which could require some re-setting of the operator’s adjustments. Doors may swell and become heavier during wet periods, door hinges and rollers might bind during cold periods. To insure safe operation of the door, perform the following tests, including any additional test steps described. Every Month 1 With the door closed, pull the red release handle to disconnect the operator from the door. 2 From outside the garage, slowly open the door manually all the way, and then close it all the way. Notice if there is any binding, sticking or rubbing. The door should move smoothly in both directions. 3 Raise the garage door about halfway up. Carefully release the door and see if the door balances. It should stay in place. Close the door. NOTE: If the garage door is unbalanced or the

IMPORTANT USER SAFETY INSTRUCTIONS

WARNING A MOVING GARAGE DOOR CAN CAUSE INJURY OR DEATH!

TO REDUCE THE RISK OF DEATH OR SEVERE INJURY:

1 READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS. 2 NEVER LET CHILDREN OPERATE, OR PLAY WITH DOOR CONTROLS! KEEP REMOTE CONTROL AWAY FROM CHILDREN! 3 Always keep moving door in sight and away from people and objects until it is completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR. 4 NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR. 5 Test door operator monthly. The garage door MUST reverse on contact with a 1-1/2 inch object (or a 2x4 board laid flat at the center of the door) on the floor. If adjusting either the force or the limit of travel, re-test the door operator. Failure to adjust the operator properly may cause severe injury or death. 6 If possible, use the red emergency release handle only when the door is closed. Use caution when using this release with the door open. Weak or broken springs may cause the door to fall rapidly, causing injury or death. 7 KEEP GARAGE DOORS PROPERLY BALANCED. (See Garage Door Operator Maintenance) An improperly balanced door could cause severe injury or death. Have a qualified service person make repairs to cables, spring assembly and other hardware.

ADJUSTING THE OPEN LIMIT

Safety Beam Test 1 Check that the operator has power. The green lights on the sender and receiver should be lit. 2 If the receiver’s green light is on, but the red light is off, the receiver has power but is not detecting the infrared beam from the sender. The red light might flash when the beam is partially detected. This can be caused by mis-alignment or something blocking the beam. Adjust the safety beam sender and receiver while watching the receiver’s red light (stay out of the beam while aligning it). When the red light stays on, rotate the sender towards the ceiling and stop when the red light on the receiver begins to flicker. Rotate the sender back towards a horizontal position with the floor and stop as soon as the red light on the receiver lights solid. The beam is now properly aligned.

DOWN UP

  • door travel isn’t smooth, have a qualified garage door professional adjust or repair the door. 4 To reconnect the operator, flip the release lever up and run the operator. 5 Perform the Safety Beam Test (Section 11). 6 Perform the Safety Reversal System Test as described in Section 15. After Servicing the Operator 1 Perform the Safety Beam Test (Section 11). 2 Perform the Open and Close Limit Adjustments (Section 13). 3 Perform the Safety Reversal System Test (Section 15). Every 6 Months Check the belt or chain tension.
  • For belt-drive rails, examine the length of the tension spring in the traveler. It should be about 1” long.
  • For chain-drive rails, examine the spacing between the turnbuckle and the rail. The turnbuckle should be slightly above the rail. NOTE: Too much or too little chain tension will cause

SAFETY BEAM INDICATORS

EXAMINE THE SPOT WHERE THE DOOR OPENS

GREEN LIGHT ON = POWER ON OFF = POWER OFF

RED LIGHT

RED LIGHT ON = BEAM ALIGNED, NO OBSTRUCTION OFF = BEAM NOT ALIGNED, OR OBSTRUCTION BLINKING = BEAM NEEDS BETTER ALIGNMENT

TO DISCONNECT OPERATOR

TO RECONNECT OPERATOR

ADJUSTING THE CLOSE LIMIT

GREEN LIGHT

8 SAVE THESE INSTRUCTIONS.

PULL THE RED RELEASE HANDLE TO DISCONNECT THE OPERATOR FROM THE DOOR

Opening the Door 1 With the door in view, press the wall station’s UP/ DOWN ARROW button or the button assigned to the operator on the remote control, or enter a valid access code and press START/STOP on a remote keypad. 2 When the operator is activated, the operator’s light will turn on and the door will begin to open. 3 The door will open until the open limit is reached. If an obstacle is encountered (operator’s light flashes four times) while the door is opening, the door will stop. 4 The operator’s light will stay on for about five minutes after the door stops.

FLIP THE LEVER UP AND RAISE OR LOWER THE DOOR TO RECONNECT THE OPERATOR

SAFETY BEAM INDICATOR TABLE GREEN ONPOWER ON GREEN OFFPOWER OFF RED ONBEAM OK - NO BLOCKAGE RED OFFBEAM BLOCKED OR MIS-ALIGNED RED FLASHINGBEAM ALIGNED POORLY

ADJUSTING THE BEAM

EXAMINE THE SPOT WHERE DOOR CLOSES

OPENING OR CLOSING THE DOOR

UP

IF DOOR BECOMES OBSTRUCTED,

PULL DOWN ON HANDLE

NOTICE

1. ADJUST THE SENDER AND RECEIVER UNTIL THE RED INDICATOR LIGHTS SOLID

WALL STATION REMOTE CONTROL

IF DOOR BECOMES OBSTRUCTED,

PULL DOWN ON HANDLE

NOTICE

DOWN

REMOTE KEYPAD

2. ADJUST SENDER UP UNTIL RECEIVER'S RED INDICATOR FLASHES

14 Automatic Door Force Setup The operator automatically measures the door force throughout the entire travel of the door each time the operator cycles. The following steps are all that’s required to setup the safety reversal system. Automatic Door Force Setup 1 Be sure that the trolley latch is up and the door is connected to the operator. 2 Operate the door through four complete open and close cycles.

3. ADJUST SENDER DOWN JUST UNTIL RECEIVER'S RED INDICATOR LIGHTS SOLID

ENTER AN ACCESS CODE

PRESS THE WALL STATION'S UP/DOWN ARROW

PRESS A REMOTE CONTROL BUTTON

- OR - - OR -

AND PRESS START/STOP

excessive sprocket noise. Chain Adjustment If necessary, use the following steps to adjust the chain. 1 Hold the turnbuckle with a flat blade screwdriver and loosen the two locknuts with a 7/16” end wrench. 2 Twist the turnbuckle to adjust the chain tension. Adjust the chain until the turnbuckle is sightly above the rail. 3 Hold the turnbuckle with a flat blade screwdriver and tighten the two locknuts with a 7/16” end wrench.

DOOR FORCE SETUP

for: 1) Dirt on the receiver’s lens, 2) Sunlight shining into the receiver’s lens, 3) A short in the safety beam wiring (from staples or at the operator terminals). 3 With the door closed and the operator disengaged from the door, press the wall station’s UP/DOWN ARROW button to move the traveler (the part on the belt or chain that the trolley engages with) to the up position (away from the door). 4 Push the wall station’s UP/DOWN ARROW button again. While the traveler is moving to the down position (toward the door), block the safety beam. THE TRAVELER MUST STOP, THEN REVERSE TO THE UP POSITION. The operator’s light and red light should flash three times. 5 Place an object in the path of the safety beam. Check that constant pressure is required on the wall station’s UP/DOWN ARROW button to cause the traveler to move toward the down position. Release the pushbutton before the operator stops; check that the traveler returns to the up position. NOTE: The garage door operator will not respond

ADJUSTING A CHAIN-DRIVE

TWIST TURNBUCKLE

CHECKING FOR REVERSAL

CHAIN TIGHTEN CHAIN LOOSEN

TURNBUCKLE LOCKNUTS

Closing the Door 1 With the door in view, press the wall station’s UP/ DOWN ARROW button or the button assigned to the operator on the remote control, or enter a valid access code and press START/STOP on a remote keypad. 2 When the operator is activated, the operator’s light will turn on and the door will begin to close. 3 The door will close until the close limit is reached. If an obstacle is encountered (operator’s light flashes four times), or the safety beam is interrupted (operator’s light flashes three times) during closing, the door will stop, then re-open. 4 The operator’s light will stay on for about five minutes after the door stops.

THE TRAVELER MUST REVERSE WHEN THE BEAM IS INTERRUPTED

SAFETY LIGHTING

LOCKNUTS

LOOSEN

DOWN

UP

OPERATE THE DOOR THROUGH FOUR FULL OPEN AND CLOSE CYCLES

HOLD TURNBUCKLE WITH FLAT BLADE SCREWDRIVER TO BACKUP LOCKNUTS

BLOCK THE BEAM WHILE THE TRAVELER IS MOVING DOWN

Belt Adjustment The tension spring in the traveler keeps the belt taut. The factory setting for the tension spring length is .9” long. If the tension spring is longer than 1”, adjust the belt. 1 Hold the traveler so the adjustment wheel is visible through the large slot. 2 Use a flat blade screwdriver to turn the adjustment wheel to compress the tension spring until its length is between .9” and 1” long. Every Year Check the door hardware for lubrication needs. Lubricate door hinges, rollers and bearings according to door manufacturer’s recommended procedures.

TO HEAD LOCKNUTS

TOWARD OPERATOR

TIGHTEN

TOWARD DOOR

15 Safety Reversal System Test The operator determines that there is an obstruction if a higher than expected amount of force is detected during a door cycle. If an obstruction is encountered during a closing cycle, the operator and door will stop then fully open. If an obstruction is encountered during an opening cycle, the operator and door will stop. Safety Reversal System Test 1 Lay a 2 x 4 board flat on the floor where it will be struck by the center of the door as it closes. 2 Verify that the door reverses when it strikes the board. The door must reverse within two seconds after striking the board.

TRAVELER

ADJUSTING A BELT-DRIVE

MEASURE THE TENSION SPRING LENGTH

WHENEVER OPERATING THE LIGHT WILL TURN ON FOR ABOUT 5 MINUTES

NOTE: A FLASHING

ADJUSTMENT WHEEL

LIGHT INDICATES

TRAVELER

TROUBLE

CHECKING FORCED CLOSURE FEATURE

VERIFY THAT CONSTANT PRESSURE IS REQUIRED ON THE WALL STATION'S PUSHBUTTON TO MAKE THE TRAVELER GO DOWN

TESTING THE SAFETY REVERSAL SYSTEM

TEST WITH SMALL OBSTACLE

LOOSEN

TIGHTEN

to a CLOSE command from a radio transmitter if the safety beam is blocked. 6 To reconnect the operator, flip the release lever up. Raise the door manually until the operator reconnects.

THE DOOR MUST REVERSE WITHIN 2-SECONDS AFTER IMPACT WITH A 2 x 4 BOARD

STOPPING THE DOOR

TURN THE ADJUSTMENT WHEEL UNTIL THE TENSION SPRING IS ABOUT 1" LONG

WALL STATION

PLACE AN OBJECT IN THE BEAM'S PATH

RELEASE PUSHBUTTON BEFORE THE OPERATOR STOPS, THE TRAVELER SHOULD RETURN TO THE UP POSITION

Stopping the Door Mid-travel 1 The door can be stopped immediately at any time by pressing the wall station’s UP/DOWN ARROW button, the remote control’s pushbutton, or press the START/STOP button on a remote keypad (if the remote keypad was used to start the door). 2 The next time the operator is activated, the door will move in the opposite direction.

REMOTE KEYPAD

19 Field Reset

2 x 4 BOARD LAID FLAT UNDER CENTER OF DOOR

In installations where the door spring, door, or hardware is being replaced, and the operator was already programmed for the old door, reset the operator’s settings using the following steps. 1 Press and hold down the UP, DOWN, and LEARN buttons at the same time for ten seconds. The red and green indicators and the operator’s light will flash twice.

2 Release the buttons. The operator will reset force settings and erase all set limits, but will still retain all programmed transmitters in memory. 3 AFTER PERFORMING A FIELD RESET, BOTH THE OPEN AND CLOSE LIMITS MUST BE ADJUSTED AND THE AUTOMATIC DOOR FORCE SETUP COMPLETED BEFORE THE OPENER WILL FUNCTION.

12 Remote Controls The operator is supplied with a three-button remote control (the second and third buttons can be used to control an additional operator or gate if it contains a Linear MegaCode™ receiver). Additional single and multi-button remote controls can be purchased. The short wire on the back of the operator serves as an antenna for the remote controls. Do not cut off the wire or the remote controls will not operate well.

REMOTE CONTROL THE DOOR CAN BE STOPPED AT ANY POSITION USING THE WALL STATION, REMOTE CONTROL,

16 Adjusting the Force Factor (Installation Option, Normally Not Used) The operator uses the peak force measured during each of the last four complete cycles plus a “force factor” to calculate the maximum allowed force setting for the current door cycle. If the calculated maximum force setting is exceeded during the current door cycle, the operator reacts to the obstruction. As door hardware conditions change over time with weather and wear, the calculation of the maximum door force setting using the four cycle running average will compensate for the current conditions of the installation. The door force is preset for the lowest amount of pressure on an obstacle to detect an obstruction. THE FACTORY SETTING IS OPTIMIZED FOR MOST INSTALLATIONS.

OR A REMOTE KEYPAD

WARNING Children operating or playing with a garage door operator can injure themselves or others. The garage door could cause serious injury or death. Do not allow children to operate the remote control(s) or the wall station. A moving garage door could injure or kill someone under it. Activate the operator only when the door is clearly visible, free of obstructions and adjusted properly.

PREPARING TO ADD OR REMOVE A REMOTE 1

PRESS THE LEARN BUTTON

Vacation Lock for Additional Security 1 Slide the wall station’s LOCK switch to the locked position to prevent remote controls from opening the door after the door is completely closed. The remotes can close the door, but not open it. The door can still be opened or closed by using the wall station’s UP/ DOWN ARROW pushbutton. NOTE: To signal that the vacation switch is locked,

20 Troubleshooting

PREVENTING REMOTES FROM OPENING THE DOOR

LAMP FLASHES TROUBLE CODEPROBLEMCAUSEREMEDY 1 FLASHNo problemRemote control entered into memoryAdd any additional remote controls (MegaCode™ type only) 2 FLASHESDoor won’t closeShorted wall station wiresCheck wall station wires. Be sure both are connected to the terminal screws. Check for a staple in the wall station wires. Remove any staples compressing the wire. 3 FLASHESDoor won’t closeSafety beam obstacleCheck for obstacles. Align the safety beam (Section 11) 4 FLASHESDoor reverses or won’t open or closeOpen or Close force exceededCheck for obstruction or binding of garage door. Perform field reset (Section 19) if necessary. 5 FLASHESDoor won’t open from transmitterRemote was activated while vacation switch was lockedUnlock vacation switch on wall station 6 FLASHESMotor ran longer than 30 secondsMechanical or electronic failureCall Technical Services Group for assistance 7 FLASHESLimit errorEncoder has detected error or down limit set above up limit.Re-set the open and close limits. If error occurs again, call Technical Services Group.

Changing the Force Factor Setting As an installation option, the operator’s “force factor” can be adjusted to change the amount of pressure exerted on an obstacle before the operator reacts to the obstruction. 1 Press both the UP and DOWN buttons for three seconds. The red and green indicators and operator’s light will flash twice. 2 Use the UP or DOWN buttons to set the force factor. Pressing the UP button increases the force factor, pressing the DOWN button decreases the force factor.

THE RED LIGHT WILL GLOW FOR 15 SECONDS

REMOTE MUST BE ENTERED WHILE RED LIGHT IS ON

LOCK UNLOCK

To Add or Remove a Remote Control 1 Press the operator’s LEARN button. The operator’s light and red light will flash once and turn on for about 15 seconds. A remote must be added or removed while the red light is still on. 2 Send a signal from a remote. The operator’s light and the red light will flash once if a remote was added, or the opener’s light and the red light will flash four times if a remote was removed. 3 Repeat Steps 1 & 2 for any additional remote controls. To Remove All Remote Controls 1 Press and hold the operator’s LEARN button for ten seconds or more. 2 Release the LEARN button. The red light and operator’s light will blink three times signaling that all of the remotes in the operator’s memory were erased. The red light will turn off, then turn on for 15 seconds. A remote control can be entered during this time using the steps above. Testing 1 Before testing the remote control, straighten out the operator’s antenna wire so it points up. 2 Stand clear of the door, press the remote control’s button and verify that the operator starts. PRESS THE REMOTE CONTROL’S BUTTON AGAIN TO STOP THE DOOR MID-TRAVEL. Replacing a Remote Control’s Batteries When the red light on the remote glows dimly, or fails to light at all when the remote is activated, the batteries need replacing. 1 Open the remote’s case and remove the circuit board. 2 Replace old batteries with two Type 2032 batteries. 3 Re-assemble the remote.

the operator’s light and red light will flash five times if a remote is activated in an attempt to open the door. 2 Slide the wall station’s LOCK switch to the unlocked position to return the operator to normal operation.

ADDING OR REMOVING A REMOTE

SLIDE THE VACATION SWITCH DOWN TO LOCK (REMOTES DISABLED) OR UP TO UNLOCK (REMOTES NORMAL)

SEND A SIGNAL FROM A REMOTE

FORCE FACTOR INDICATOR TABLE GREEN ONLOW FORCE FACTOR RED & GREEN ONMEDIUM FORCE FACTOR RED ONHIGH FORCE FACTOR

THE OPERATOR'S LIGHT AND RED LIGHT WILL FLASH ONCE IF A REMOTE IS ADDED, THE OPERATOR'S

PRESS A BUTTON - OR -

LIGHT AND THE RED LIGHT

CONTROLLING THE OPERATOR'S LIGHT

ENTER A CODE AND PRESS START/STOP

WILL FLASH FOUR TIMES IF A REMOTE IS REMOVED

Controlling the Operator’s Light 1 The operator’s light can be lit by pushing the wall station’s LIGHT button. The light will remain on until the LIGHT button is pressed again or the operator is cycled. 2 If the operator’s light is on, pushing the wall station’s LIGHT button will turn the operator’s light off.

3 After selecting the force factor, press the LEARN button to store the setting and exit setup. The red and green indicators and the operator’s light will flash two times. (If the force factor is not set within one minute, the operator will return to normal operation at its previous force factor setting.) 4 After changing the force factor setting, perform the Safety System Reversal Test.

2 REMOVING ALL REMOTES THE RED LIGH AND OPERATOR’S LIGHT

T

FCC NOTICE

WILL BLINK 3 TIMES SIGNALING THAT ALL REMOTES WERE REMOVED

Changes or modifications not expressly described in this manual or approved by the manufacturer could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Industry Canada and Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

PRESS THE LIGHT BUTTON TO TURN THE LIGHT ON OR OFF

THE LIGHT WILL STAY ON UNTIL THE LIGHT BUTTON IS PRESSED OR THE OPERATOR IS CYCLED

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help. LIMITED WARRANTY

PRESS THE LEARN BUTTON FOR 10 SECONDS OR MORE

This Linear product is warranted to the original consumer against defects in material and workmanship for: MODEL ELECTRONICS MECHANICAL MOTOR BELT CHAIN LDCO800 1 year 5 years Lifetime Lifetime 5 years This product is warranted to the original consumer against defects in material and workmanship for the periods mentioned above. Linear will repair, or at its option, replace, any device that it finds requires service under this warranty, and will return the repaired or replaced device to the consumer at Linear’s cost. Devices must be sent to Linear for service at owner’s expense. This warranty does not apply to damage to the product from negligence, abuse, abnormal usage, misuse, accidents, normal wear or tear or due to failure to follow Seller’s instructions, or arising from improper installation, storage or maintenance. In no event will Linear be responsible for incidental, compensatory, punitive, consequential, indirect, special or other damages. The remedies provided by this warranty are exclusive. Some states do not allow the exclusion or limitation of incidental and consequential damages, so the above limitation or exclusion may not apply to you. Any warranties implied by law are limited to the time periods set forth above. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. For warranty service and shipping instructions contact Linear at the phone number shown below. In order to be protected by this warranty, save your proof of purchase and send a copy with equipment should repair be required. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.

REPLACING A REMOTE'S BATTERY

IN CASE OF POWER FAILURE OR IF DOOR BECOMES OBSTRUCTED

Disconnecting the Door from the Operator 1 With the door in any position (preferably closed), carefully pull the red release handle. USE CAUTION IF THE DOOR IS OPEN, THE DOOR MAY DROP. 2 The disconnected door can be opened or closed manually. 3 To re-connect the operator, flip the release lever up. Raise or lower the door manually until the operator reconnects.

1 TWIST DIME IN SLOT TO OPEN CASE

2 LIFT OFF THE TOP OF THE CASE

3 CAREFULLY REMOVE THE CIRCUIT BOARD

PULL THE RED RELEASE HANDLE TO DISCONNECT THE OPERATOR FROM THE DOOR

FLIP THE LEVER UP AND RAISE OR LOWER THE DOOR TO RECONNECT THE OPERATOR

4 REMOVE OLD BATTERIES AND DISPOSE OF THEM PROPERLY

5 INSERT TWO NEW TYPE 2032 BATTERIES PLUS SIDE UP THEN REASSEMBLE UNIT

IF DOOR BECOMES OBSTRUCTED,

PULL DOWN ON HANDLE

NOTICE

IF DOOR BECOMES OBSTRUCTED,

PULL DOWN ON HANDLE

NOTICE

Copyright © 2010 Linear LLC 228355 C

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
1 FLASHRemote control entered into memoryAdd any additional remote controls (MegaCode™ type only) p.2
2 FLASHESShorted wall station wiresCheck wall station wires. Be sure both are connected to the terminal screws. Check for a staple in the wall station wires. Remove any staples compressing the wire. p.2
3 FLASHESSafety beam obstacleCheck for obstacles. Align the safety beam (Section 11) p.2
4 FLASHESOpen or Close force exceededCheck for obstruction or binding of garage door. Perform field reset (Section 19) if necessary. p.2
5 FLASHESRemote was activated while vacation switch was lockedUnlock vacation switch on wall station p.2
6 FLASHESMechanical or electronic failureCall Technical Services Group for assistance p.2
7 FLASHESEncoder has detected error or down limit set above up limit.Re-set the open and close limits. If error occurs again, call Technical Services Group. p.2

Ask about the Linear LDCO800

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Linear LDCO800

Be the first to ask — other owners or our team will answer.

Original document

Linear LDCO800 manual PDF

2 pages·1.1 MB·Garage Door Opener·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…