7 Install the Wall Stationp.1MARKING THE CENTERLINEp.1INSTALLING THE DOOR BRACKETp.1DOOR BRACKETp.1DOOR STRUCTURALp.1INSTALLATION INSTRUCTIONSp.1SUPPORTp.1CONNECTING AND LOCATING THE WALL STATIONp.1For Sectional Type Doors IMPORTANT SAFETY NOTESp.1CONNECT PUSHBUTTON WIRES TO WALL STATION'S TERMINALSp.1MARKING ABOVE THE HIGH-RISE POINTp.1CONNECTING THE DOOR ARM TO THE DOOR BRACKETp.1MARK HEADER 1" ABOVEp.1CONNECT SINGLE-HOLE END OF DOOR ARMp.1THE FOLLOWING FORMATS ARE USED FORp.1HIGH-RISE POINTp.1INSTALL HITCH PINp.1CURVEDp.1DOORp.1ARMp.11-3/8" CLEVISp.1SECTIONAL DOORp.1PINp.1MOUNTING THE WALL STATIONp.1CONNECTING THE DOOR ARM TO THE TROLLEYp.1ATTACHING THE HEADER BRACKETp.1USE WOOD SCREWS WHEN MOUNTING DIRECTLY TO WALLp.11/2" SOCKETp.1CENTERLINE OF DOORp.1ROUTE WIRE THROUGH SLOT IN CASEp.1TROLLEYp.1SLIDE IN THE 1-1/8" CLEVIS PINp.11 INCH (SECTIONAL)p.1PUT HOLE PLUGS IN TO HIDE SCREWSp.1IMPORTANT INSTALLATION SAFETY INSTRUCTIONSp.1INSTALL THE HITCH PINp.1HIGH-RISE POINT OF DOORp.1STRAIGHT DOOR ARMp.1CONNECTING THE DOOR ARMSp.1THESE INSTALLATION SAFETY STEPS BEFORE PROCEEDINGp.112" (APPROXIMATELY)p.12" TO 4"p.110 Connect the Operator to Power Sourcep.1MARKING THE CORRECT BEAM BRACKET HEIGHTp.1POWERING THE OPERATORp.1CEILING OUTLETp.1ADJUSTING OPERATOR HEIGHTp.1CHECKING THE DOOR BALANCEp.1PLUG OPERATOR INTO GROUNDED OUTLETp.1INSTALLING THE BEAMSp.1ADJUST HEIGHT AS REQUIREDp.1FOR PERMANENT WIRING ONLY!p.1REMOVING THE POWER CORDp.1BE SURE THE POWER CORD IS UNPLUGGED!!p.1HANGING BRACKET OPTIONSp.1TWIST UNIT TO LOCK INTO BRACKETp.1SET TROLLEY LOCATIONp.1INSERT UNIT INTO BRACKETp.1TYPICAL HANGING BRACKETS SCREWED DIRECTLY TO JOISTSp.1SET TROLLEY 12" FROM PULLEY BRACKETp.1PRE-ADJUSTING THE BEAMSp.1ALIGNING THE RAILp.1TYPICAL HANGING BRACKET ASSEMBLY USING A CROSSPIECEp.1ADJUST UNITS SO LENSES POINT TOWARD EACH OTHERp.1CHAIN DRIVE BELT DRIVEp.1REMOVING THE BUSHINGp.1REMOVE STRAIN RELIEF BUSHING WITH PLIERSp.1INSTALLING THE BEAM COVERSp.1MATING THE SPROCKET AND SHAFTp.1SLIDE THE SPROCKET INTO THE SHAFTp.1COVER SNAPS ONTO BRACKET WITH FOUR TABSp.1CHAIN DRIVEp.1TABS FIT INTO SLOTSp.1BELT DRIVEp.1ATTACHING THE RAILp.1TIGHTEN THE RAIL-TO-HEAD BOLTS IN THIS ORDERp.1CONNECTING THE BEAM WIRESp.1BEAM WIRESp.1HARDWIRING THE OPERATORp.1CONDUIT WIRE NUTSp.1
Page 1 of the Linear LCO75 user manual — HCI-12 12-FOOT I-RAIL
Page 1 · click to enlarge
Page 1

LINEAR LLC (760) 438-7000 USA & Canada (800) 835-5666 & (800) 421-1587

3 Locate the Header Bracket Position 1 Close the door. 2 From inside the garage, use a pencil to mark the vertical centerline of the door on the header wall and on the top panel of the door. 3 Examine the area above the center of the door on the door header wall for a header bracket mounting location. 4 Open the door to the high-rise point (the point where the top edge of the door is highest above the fl oor) and measure the distance to the fl oor. 5 Close the door and use a pencil to mark the header wall 1” above the measured high-rise point. ➤ NOTE: In some installations, the header bracket

7 Install the Wall Station

9 Install the Door Bracket and Door Arm 1 Fully close the door. Hold the door bracket against the inside of the door’s top panel. Align the top edge of the bracket 2” to 4” below the top edge of the door; or, if there is a structural support across the top of the door, place the top edge of the bracket directly below the support. Align the vertical centerline drawn on the door with the center of the bracket. See the fi gure for details. Mark the left and right holes of the bracket. 2 Drill ¼” holes at marks and insert two ¼-20 x 2” carriage bolts (not supplied) from outside of door through the door bracket. 3 Secure door bracket with two ¼-20 keps nuts (not supplied). Tighten with a 7/16” socket. 4 Slide the 5/16” x 1-3/8” clevis pin through one hole on door bracket; then the single hole on the curved door arm; then through the other hole on the door bracket. Secure the clevis pin with the hitch pin. 5 Insert the single hole end of the straight door arm into the slot in the trolley. Slide the 1-1/8” clevis pin through the hole and secure it with a hitch pin. 6 Flip the trolley release lever to disconnect the trolley. 7 Rotate the curved door arm upward to meet the straight door arm connected to the trolley. Align the two door arms so that the holes in both arms overlap. ➤ NOTE: The straight door arm should be slightly angled

MARKING THE CENTERLINE

MARK THE CENTERLINE OF THE DOOR ON THE HEADER AND THE TOP DOOR PANEL

WARNING Children operating or playing with a garage door operator can injure themselves or others. The garage door could cause serious injury or death. Do not allow children to operate the remote control(s) or the wall station. Install the wall station out of reach of children and away from all moving parts of the door. The door must be clearly visible from the wall station. A moving garage door could injure someone under it. Only activate the door when it is properly adjusted, when it can be seen clearly and when there are no obstructions to the door travel.

INSTALLING THE DOOR BRACKET

Toll Free FAX (800) 468-1340

DOOR BRACKET

www.linearcorp.com

MODEL LCO75 LIGHT-DUTY CHAIN-DRIVE COMMERCIAL GARAGE DOOR OPERATOR RESIDENTIAL BELT-DRIVE/CHAIN-DRIVE GARAGE DOOR OPERATOR

ALIGN THE DOOR BRACKET ON THE CENTERLINE 2" TO 4"

DOOR STRUCTURAL

BELOW THE TOP EDGE OF THE DOOR, OR DIRECTLY

BELOW ANY DOOR STRUCTURAL SUPPORT DRILL TWO 1/4" PILOT HOLES USE TWO 1/4-20 x 2" CARRIAGE BOLTS AND NUTS (NOT SUPPLIED) TO ATTACH THE DOOR BRACKET

INSTALLATION INSTRUCTIONS

SUPPORT

➤ NOTE22 AWG 2-conductor wall station and safety

CONNECTING AND LOCATING THE WALL STATION

beam wire is supplied with the operator, Use this wire or the installation’s pre-wiring. For additional wire, contact Linear for information regarding the 24-pack Model HAE00009 wire and wire clip kit. ➤ UL NOTE: All low voltage Class 2 cable used with this

For Sectional Type Doors IMPORTANT SAFETY NOTES

CONNECT PUSHBUTTON WIRES TO WALL STATION'S TERMINALS

MARKING ABOVE THE HIGH-RISE POINT

CONNECTING THE DOOR ARM TO THE DOOR BRACKET

MARK HEADER 1" ABOVE

CONNECT SINGLE-HOLE END OF DOOR ARM

location will be higher than the door header. This will require adding a 2x4 (or larger) cross piece to the wall studs to provide a mounting location for the header bracket. Use lag screws (not supplied) to attach the 2x4 to the studs. 6 On doors with low headroom, the header bracket can be attached to the ceiling up to 6” back from the header wall (see next step).

THE FOLLOWING FORMATS ARE USED FOR

HIGH-RISE POINT

INSTALL HITCH PIN

Please read the instructions carefully! This garage door operator is designed to provide safe and reliable service if installed and tested as described in these instructions. A garage door is the largest mechanical appliance in a residence. Care must be taken to prevent injury or death during installation and operation of the garage door and garage door operator.

SAFETY NOTES IN THESE INSTRUCTIONS.

operator must be UL Listed Type CL2, CL2P, CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and fl ammability ratings. 1 Strip back ½” of insulation and connect a wire to each of the two terminals on the back of the wall station. 2 Use the screws provided to mount the wall station near an access door at a minimum height of fi ve feet. SEE IMPORTANT WARNING ABOVE! 3 For non-prewired installations, route the wire to the back of the operator. Use insulated staples (not supplied) to secure the wire. Staples must straddle both wires to avoid electrical shorts. 4 Cut the wall station wire about 6” longer than needed to reach the operator terminals. Strip back ½” of insulation. 5 Connect either wire to the operator’s PUSHBUTTON terminal and the other wire to the operator’s COMMON terminal. 6 Apply the User Safety Instruction Label (residential) to the wall next to the wall station in a prominent location. Use staples or tacks to help the label remain in place over time. 7 Install the Entrapment Warning Placard and Duty Rating Label (commercial) on the wall next to the door. Use screws to secure the placard to the wall. ➤ IMPORTANT! DO NOT PLUG THE OPERATOR IN AT

MOUNT WALL STATION AT LEAST 5 FEET ABOVE THE FLOOR LEVEL

CURVED

DOOR

ARM

1-3/8" CLEVIS

SECTIONAL DOOR

PIN

MOUNTING THE WALL STATION

USE MACHINE SCREWS WHEN MOUNTING TO A SINGLE-GANG BOX

4 Install the Header Bracket 1 Hold the header bracket on the center line drawn above the door with the bottom edge of the bracket on the line marked above the high-rise point. 2 Use a pencil to mark the two bracket holes. 3 Drill two 3/16” pilot holes about 2” deep. 4 Use a ½” socket to fasten the bracket with two 5/16” x 2” lag screws.

CONNECTING THE DOOR ARM TO THE TROLLEY

ATTACHING THE HEADER BRACKET

USE WOOD SCREWS WHEN MOUNTING DIRECTLY TO WALL

1/2" SOCKET

CENTERLINE OF DOOR

ROUTE WIRE THROUGH SLOT IN CASE

TROLLEY

ATTACH HEADER BRACKET WITH TWO 5/16" x 2" LAG SCREWS

toward the operator head. 8 Line up door arms until trolley is positioned as shown. Connect the arms together using two 5/16-18 x 1” bolts inserted in the highest and lowest matching holes, secure the bolts with two 5/16” keps nuts, tighten with a ½” socket.

SLIDE IN THE 1-1/8" CLEVIS PIN

1 INCH (SECTIONAL)

PUT HOLE PLUGS IN TO HIDE SCREWS

IMPORTANT INSTALLATION SAFETY INSTRUCTIONS

INSTALL THE HITCH PIN

HIGH-RISE POINT OF DOOR

STRAIGHT DOOR ARM

Linear LCO75 — HIGH-RISE POINT OF DOOR diagram (page 1)
Fig. 1

CONNECTING THE DOOR ARMS

THESE INSTALLATION SAFETY STEPS BEFORE PROCEEDING

5 Connect the Rail to the Header Bracket 1 Place assembled operator on the empty carton on the fl oor with rail towards the door. 2 Insert the end of the rail into header bracket. 3 Insert the 5/16” x 2-3/8” clevis pin through header bracket and rail. 4 Secure the clevis pin with the hitch pin.

Linear LCO75 — CONNECTING THE DOOR ARMS diagram (page 1)
Fig. 2

12" (APPROXIMATELY)

1 READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS. 2 Install only on a properly balanced garage door. An improperly balanced door could result in severe injury or death. Repairs to cables, spring assemblies, and other hardware must be made by a qualifi ed service person before installing the operator. 3 Remove all pull ropes and remove, or make inoperative, all locks (unless mechanically and/or electrically interlocked to the power unit) that are connected to the door before installing the operator. Ropes connected to a garage door can cause entanglement and death. 4 If possible, install door operator 7 feet or more above the fl oor with the manual release handle mounted 6 feet above the fl oor. Instruct the end user on the operation of the manual release. 5 Do not connect the operator to the power source until instructed to do so. 6 Locate the wall station within sight of the door at a minimum height of 5 feet so that small children cannot reach it. Locate the wall station away from all moving parts of the door. 7 Residential Installations: Install the User Safety Label on the wall adjacent to the wall station. Commercial Installations: Install the Entrapment Warning Placard and Duty Rating Label in a prominent location visible in the area of the door. 8 Upon completion of the installation, the door must reverse when it comes in contact with a 1-1/2” high object (or a 2x4 laid fl at at the center of the door) on the fl oor and when the infrared safety beam is blocked. 9 Do not wear watches, rings or loose clothing while installing or servicing an operator. Jewelry or loose clothing can be caught in the mechanism of the garage door or the operator. 10 DISCONNECT THE ELECTRIC POWER FROM THE GARAGE DOOR OPERATOR BEFORE MAKING ANY REPAIRS OR REMOVING THE COVER. 11 Commercial Installations: The rate of operation must not exceed 13 cycles of opening and closing per hour.

LINE UP DOOR ARMS UNTIL TROLLEY IS POSITIONED AS SHOWN CONNECT ARMS WITH TWO 5/16-18 x 1" BOLTS IN THE HIGHEST AND LOWEST MATCHING HOLES

CONNECT THE WALL STATION WIRES TO PUSHBUTTON AND COMMON TERMINALS (EITHER WIRE TO EITHER TERMINAL)

2" TO 4"

10 Connect the Operator to Power Source

6 Hang the Operator Installation requirements vary with garage construction. Hanging brackets should be angled to provide rigid support. Hanging material is not provided. Angle iron and lag screws are recommended. DO NOT USE NAILS. Following are typical operator hanging methods. Certain installations will require improvised methods. 1 Raise the operator head and set it on top of a stepladder (use extra spacers on top of ladder if it isn’t tall enough). 2 Carefully open the door to the full up position. Lay a 2x4 across the top section of the door as a spacer. Adjust the operator height until the rail touches the spacer. The rail should be close to level. 3 Center the operator head and rail with the centerline mark on the top of the door. 4 For fi nished ceilings only: An angle iron cross piece between the two closest joists above the operator will be required. Mark mounting hole locations, drill pilot holes and attach the piece with two lag screws (not supplied). 5 Measure the distance from each of the operator’s hanging tabs to the ceiling joists or angle iron cross piece. 6 Cut two angle iron pieces to the required lengths for hanging brackets. Bend brackets if required. • For unfi nished ceilings: Hold each bracket in place

ASSEMBLE BRACKETS WITH 1/4-20 x 1/2" BOLTS AND KEPS NUTS

Cord and Outlet Connection The operator should be connected to a grounded receptacle on the ceiling or near the operator head. If none is available which will accept the grounded operator plug, one should be installed by a qualifi ed electrician. Do not use an extension cord. 1 Plug the operator into a grounded receptacle. 2 When the operator is plugged in, a click should sound in the operator and the lights should turn on. If the lights do not turn on, check the power source and light bulbs. Permanent Wiring SOME LOCAL ELECTRICAL CODES REQUIRE PERMANENT WIRING BETWEEN THE OPERATOR AND THE POWER SOURCE THROUGH A CONDUIT. IT IS RECOMMENDED THAT YOU HAVE A LICENSED ELECTRICAL CONTRACTOR FOLLOW THESE STEPS ONLY IF PERMANENT WIRING IS REQUIRED. 1 BE SURE POWER CORD IS UNPLUGGED. 2 Cut the power cord about 2” above the strain relief bushing on the operator. 3 Remove the four side screws and bottom cover of operator. 4 Use pliers to remove the strain relief bushing and discard the bushing. 5 Remove the outer insulation from the power cord and strip the white, black, and green wire insulation back about ½”. 6 Pull white (neutral), black (hot) and green (ground) wires through conduit. 7 Connect the conduit to the operator with the appropriate termination. 8 Use wire nuts (not supplied) to connect the wires to the matching color wires inside operator head. 9 Secure the wires away from all moving parts with a zip-tie as shown in the fi gure. 10 Replace the operator cover and the four side screws. 11 Connect the conduit wires to the power source at junction box. 12 When power is applied to the operator, a click should sound and the lights should turn on. If the lights do not turn on, check the power source, wiring, and light bulbs.

➤ NOTEThe safety beam’s infrared light beam must

not be obstructed by the door, or by any part of the door hardware. Use wooden spacers between the beam brackets and wall if necessary to create proper clearance. 1 Assemble the two safety beam brackets from the four L-shaped brackets using two ¼-20 x ¾” bolts and ¼-20 keps nuts (one nut & bolt for each bracket).

MARKING THE CORRECT BEAM BRACKET HEIGHT

POWERING THE OPERATOR

CEILING OUTLET

ADJUSTING OPERATOR HEIGHT

1 Check the Door Balance 1 From outside the garage, slowly open the door all the way, and then close it all the way. Notice if there is any binding, sticking or rubbing. The door should move smoothly in both directions. 2 Raise the garage door about halfway up. Carefully release the door and see if the door balances. It should stay in place. Close the door. ➤ IMPORTANT: If the garage door is unbalanced or

PLACE A 2x4 SPACER BETWEEN THE DOOR AND RAIL

CHECKING THE DOOR BALANCE

LOCATE THE SAFETY BEAM BRACKETS SO THE BEAM CENTERLINE IS 6" ABOVE THE FLOOR

2 Position the assembled brackets on each side of the door so the center line of the safety beam lenses will be 6” above the fl oor. Use the index marks on the brackets to make the bracket assemblies equal lengths. Mark the locations for the bracket mounting screws (the brackets can be wall or fl oor mounted). ➤ NOTE: The safety beam receiver (the unit with two

PLUG OPERATOR INTO GROUNDED OUTLET

INSTALLING THE BEAMS

ADJUST HEIGHT AS REQUIRED

THE DOOR SHOULD BALANCE WITHOUT GOING UP OR DOWN

indicators) should be located on the “shady” side of the door to prevent sunlight from shining directly into the receiver’s lens. 3 Drill two 3/16” pilot holes for lag screws at marks. Mount the brackets with two ¼” x 1-1/4” lag screws and tighten with a 7/16” socket (or use proper concrete fasteners if fl oor mounting). 4 Insert the sender and receiver into the bracket holes so the lenses of the units will face each other. Twist the units until the spring clips lock into a detent mark on the brackets. To protect the units from being bumped after installation, it is recommended to mount the sender and receiver inside the brackets as shown. 5 Install the two safety beam protective covers over the beam units to protect them from damage. ➤ IMPORTANT: Be careful to route the safety beam wiring

FOR PERMANENT WIRING ONLY!

the door travel isn’t smooth, have a qualifi ed garage door professional adjust or repair the door.

and use a pencil to mark the locations where they will be attached to the joists, drill pilot holes and attach the pieces with two lag screws (not supplied). • For fi nished ceilings with an angle iron cross piece:

REMOVING THE POWER CORD

BE SURE THE POWER CORD IS UNPLUGGED!!

2 Attach the Rail to the Operator 1 Place the operator head on the garage fl oor with cardboard underneath it to protect the fi nish. 2 Manually turn the sprocket two full turns counterclockwise to align the trolley approximately 12 inches from the pulley bracket (see fi gure). 3 Align the rail over the center of the operator head. 4 Be sure the fl at on the sprocket lines up with the fl at on the drive shaft. 5 Slide the sprocket onto the shaft. 6 Attach the rail to the operator head by installing four ¼-20 x ¾” bolts. 7 Tighten the four bolts in the order shown with a 7/16” socket.

HANGING BRACKET OPTIONS

TWIST UNIT TO LOCK INTO BRACKET

SET TROLLEY LOCATION

INSERT UNIT INTO BRACKET

CUT THE CORD ABOUT 2" ABOVE THE STRAIN RELIEF BUSHING

Attach the two hanging brackets to the cross piece with two bolts and two keps nuts (not supplied). 7 Attach operator to hanging brackets using two 5/16-18 x 1” hex bolts and two 5/16-18 keps nuts (supplied). Insert bolts from the inside of hanger brackets with the nuts on the outside of the operator. Tighten nuts with a ½” socket. 8 When using a 12-foot or longer I-rail, install the center rail support bracket at the middle of the rail. The bracket attaches with a strap (not included) to a vertical support. 9 Tighten all hanging hardware. 10 Open and close the door manually. The door should clear the rail by at least 1”. 11 Attach the trolley’s release lever to the red release handle with the cord supplied so the handle is at least 6 feet from the fl oor. Cut off any excess cord. 12 Press the light cover release tabs in to open the covers. Install two 100 watt maximum rough service lamps. Swing the light covers closed, snapping them shut.

TYPICAL HANGING BRACKETS SCREWED DIRECTLY TO JOISTS

SET TROLLEY 12" FROM PULLEY BRACKET

PRE-ADJUSTING THE BEAMS

ALIGNING THE RAIL

LINE UP THE RAIL OVER THE DRIVE SHAFT ON TOP OF THE OPERATOR HEAD

TYPICAL HANGING BRACKET ASSEMBLY USING A CROSSPIECE

ADJUST UNITS SO LENSES POINT TOWARD EACH OTHER

FOR PERMANENT WIRING ONLY!

SPRING CLIP LATCHES INTO DETENT MARKS TO HOLD UNIT'S POSITION

CHAIN DRIVE BELT DRIVE

away from any moving parts of the door or operator. 6 For non-prewired installations, route the wires from the sender and receiver, up the wall above the door hardware, then over to the center of the door, then along the top of the rail (or ceiling), and back to the operator head. Cut the wires about 6” longer than needed to reach the operator terminals. Strip back ½” of insulation from the ends of the wires. 7 For non-prewired installations, secure all the wires to the wall and ceiling with insulated staples (not supplied). Staples must straddle both wires to prevent shorts. Secure the wire to the top of the rail with wire clips (supplied). 8 At the operator, twist one wire from each pair together, then twist the other wire from each pair together. 9 Attach either twisted connection to the operator’s BEAM terminal. Connect the other twisted connection to the operator’s COMMON terminal.

REMOVING THE BUSHING

BE SURE THE FLAT ON THE SPROCKET LINES UP WITH THE FLAT ON THE DRIVE SHAFT

Linear LCO75 — REMOVING THE BUSHING diagram (page 1)
Fig. 3

HANG THE OPERATOR WITH TWO 5/16-18 x 1" BOLTS AND NUTS

REMOVE STRAIN RELIEF BUSHING WITH PLIERS

INSTALLING THE BEAM COVERS

MATING THE SPROCKET AND SHAFT

SLIDE THE SPROCKET INTO THE SHAFT

COVER SNAPS ONTO BRACKET WITH FOUR TABS

MAXIMUM DOOR AREA (IN SQUARE FEET) STANDARD SECTIONAL DOORS DOOR SIZE (SQ. FT.)DOOR CONSTRUCTION Insulated SteelNon-insulated SteelOther Construction 250Fiberglass 21024 Gauge 22 GaugeAluminum 18024 Gauge20 GaugeWood 120 8020 Gauge 16 Gauge16 Gauge NOTE: On steel insulated doors, a 24 gauge back panel is assumed.

THE PROTECTIVE COVER CAN ATTACH TO EITHER SIDE OF THE BRACKET

CHAIN DRIVE

TABS FIT INTO SLOTS

BELT DRIVE

FOR PERMANENT WIRING ONLY!

ATTACHING THE RAIL

TIGHTEN THE RAIL-TO-HEAD BOLTS IN THIS ORDER

CONNECTING THE BEAM WIRES

BEAM WIRES

HARDWIRING THE OPERATOR

CONDUIT WIRE NUTS

ATTACH THE SUPPORT BRACKET AT THE CENTER OF THE RAIL

WALL STATION WIRES

INSTALL FOUR 1/4-20 x 3/4" RAIL-TO-HEAD BOLTS USING A 7/16" SOCKET (SEE TORQUE ORDER BELOW)

CONNECT CONDUIT WIRING TO OPERATOR WIRING WITH WIRE NUTS

PULL THE CHAIN OR BELT AWAY FROM THE RAIL TO FIT THE SOCKET ON THE FRONT BOLTS

GREEN - GROUND WHITE - NEUTRAL BLACK - HOT

CONNECT THE SAFETY BEAM WIRES TO COMMON AND BEAM TERMINALS (EITHER WIRE TO EITHER TERMINAL)

HCI-12 12-FOOT I-RAIL

12"

Page 2 of the Linear LCO75 user manual — IF DOOR BECOMES OBSTRUCTED,
Page 2 · click to enlarge
Page 2

11 Aligning the Infrared Safety Beam The safety beam has two components, a sender and a receiver. The sender produces a narrow infrared beam that travels across the bottom of the door opening to the infrared receiver. If an object blocks the infrared beam while the door is closing, the door will stop, then reverse and fully open (the operator’s light will fl ash three times). As a safety feature, the operator will ignore signals from all remote controls if the door is open and the infrared safety beam is blocked or out of alignment. In this case, the door can be forced closed by pressing and holding the wall station’s up/down arrow pushbutton (be sure the door area is in clear view).

13 Adjusting the Open and Close Limits The limit adjustments that control how far the door will open or close are located on the side of the operator. The limits should be adjusted so the door opens just short of any door stops, and closes right at the fl oor level. Each full turn of a limit adjustment equals about 2-½” of door travel.

15 Using the Garage Door Operator

16 Garage Door Operator Maintenance Weather conditions may affect the door operation which could require some re-setting of the operator’s adjustments. Doors may swell and become heavier during wet periods, door hinges and rollers might bind during cold periods. To insure safe operation of the door, perform the following tests, including any additional test steps described. Every Month 1 With the door closed, pull the red release handle to disconnect the operator from the door. 2 From outside the garage, slowly open the door manually all the way, and then close it all the way. Notice if there is any binding, sticking or rubbing. The door should move smoothly in both directions. 3 Raise the garage door about halfway up. Carefully release the door and see if the door balances. It should stay in place. Close the door. ➤ NOTE: If the garage door is unbalanced or the

CHECKING WHERE THE DOOR STOPS

IMPORTANT USER SAFETY INSTRUCTIONS

DOWN UP

WARNING A MOVING GARAGE DOOR CAN CAUSE INJURY OR DEATH!

TO REDUCE THE RISK OF DEATH OR SEVERE INJURY:

EXAMINE THE SPOT WHERE THE DOOR STOPS OPENING

1 READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS. 2 NEVER LET CHILDREN OPERATE, OR PLAY WITH DOOR CONTROLS! KEEP REMOTE CONTROL AWAY FROM CHILDREN! 3 Always keep moving door in sight and away from people and objects until it is completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR. 4 NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR. 5 Test door operator monthly. The garage door MUST reverse on contact with a 1-1/2 inch object (or a 2x4 board laid fl at at the center of the door) on the fl oor. If adjusting either the force or the limit of travel, re-test the door operator. Failure to adjust the operator properly may cause severe injury or death. 6 If possible, use the red emergency release handle only when the door is closed. Use caution when using this release with the door open. Weak or broken springs may cause the door to fall rapidly, causing injury or death. 7 KEEP GARAGE DOORS PROPERLY BALANCED. (See Garage Door Operator Maintenance) An improperly balanced door could cause severe injury or death. Have a qualifi ed service person make repairs to cables, spring assembly and other hardware.

SETTING THE OPEN LIMIT

USE A SCREWDRIVER TO ADJUST THE OPEN LIMIT

Safety Beam Test 1 Check that the operator has power. The green lights on the sender and receiver should be lit. 2 If the receiver’s green light is on, but the red light is off, the receiver has power but is not detecting the infrared beam from the sender. The red light might fl ash when the beam is partially detected. This can be caused by mis-alignment or something blocking the beam. Adjust the safety beam sender and receiver while watching the receiver’s red light (stay out of the beam while aligning it). When the red light stays on, the beam is aligned.

1 Activate the remote control. Wait while the door moves to the open position and stops. 2 Examine the position of the door. • If the door needs to open more, turn the OPEN LIMIT

SAFETY BEAM INDICATORS

  • door travel isn’t smooth, have a qualifi ed garage door professional adjust or repair the door. 4 To reconnect the operator, fl ip the release lever up. Raise the door manually until the operator reconnects. 5 Perform the Safety Beam Test (Section 11). 6 Perform the Safety Reversal System Test as described in Steps 4-6 in Section 14. After Servicing the Operator 1 Perform the Safety Beam Test (Section 11). 2 Perform the Open and Close Limit Adjustments (Section 13). 3 Perform the entire Door Force Safety System Test (Section 14). Every 6 Months Check the belt or chain tension.
  • For belt-drive rails, examine the length of the tension spring in the traveler. It should be about 1” long.
  • For chain-drive rails, examine the spacing between the turnbuckle and the rail. The turnbuckle should be slightly above the rail. ➤ NOTE: Too much or too little chain tension will cause

adjustment clockwise ¼-turn (towards UP on the label) to raise the open limit. • If the door needs to open less, turn the OPEN LIMIT

GREEN LIGHT ON = POWER ON OFF = POWER OFF

RED LIGHT

adjustment counterclockwise ¼-turn (towards DOWN on the label) to lower the open limit. 3 Activate the remote control. Wait for the door to move down a few feet, then activate the remote control again to stop the door. 4 Repeat Steps 1-3 until the open limit is properly adjusted. 5 Activate the remote control. Wait while the door moves to the closed position and stops. 6 Examine the position of the door. • If the door needs to close more, turn the CLOSE

OPEN LIMIT ADJUSTMENT UP DOWN

RED LIGHT ON = BEAM ALIGNED, NO OBSTRUCTION OFF = BEAM NOT ALIGNED, OR OBSTRUCTION BLINKING = BEAM NEEDS BETTER ALIGNMENT

CHECKING WHERE THE DOOR STOPS

TO DISCONNECT OPERATOR

TO RECONNECT OPERATOR

SAFETY BEAM INDICATOR TABLE GREEN ONPOWER ON GREEN OFFPOWER OFF RED ONBEAM OK - NO BLOCKAGE RED OFFBEAM BLOCKED OR MIS-ALIGNED RED FLASHINGBEAM ALIGNED POORLY

GREEN LIGHT

8 SAVE THESE INSTRUCTIONS.

ADJUSTING THE BEAM

Opening the Door 1 With the door in view, press the wall station’s UP/ DOWN ARROW button or the button assigned to the operator on the remote control, or enter a valid access code and press START/STOP on a remote keypad. 2 When the operator is activated, the operator’s lights will turn on and the door will begin to open. 3 The door will open until the open limit is reached. If an obstacle is encountered (operator’s lights fl ash four times) while the door is opening, the door will stop. 4 The operator’s lights will stay on for about fi ve minutes after the door stops.

PULL THE RED RELEASE HANDLE TO DISCONNECT THE OPERATOR FROM THE DOOR

EXAMINE THE SPOT WHERE DOOR STOPS CLOSING

OPENING OR CLOSING THE DOOR

UP

FLIP THE LEVER UP AND RAISE OR LOWER THE DOOR TO RECONNECT THE OPERATOR

ADJUST THE SENDER AND RECEIVER UNTIL THE RED INDICATOR LIGHTS SOLID

WALL STATION REMOTE CONTROL

IF DOOR BECOMES OBSTRUCTED,

PULL DOWN ON HANDLE

NOTICE

REMOTE KEYPAD

IF DOOR BECOMES OBSTRUCTED,

PULL DOWN ON HANDLE

NOTICE

➤ NOTEIf the receiver’s red light remains off, check

LIMIT adjustment counterclockwise ¼-turn (towards DOWN on the label) to lower the close limit. • If the door needs to close less, turn the CLOSE LIMIT

DOWN

for: 1) Dirt on the receiver’s lens, 2) Sunlight shining into the receiver’s lens, 3) A short in the safety beam wiring (from staples or at the operator terminals). 3 With the door closed and the operator disengaged from the door, press the wall station’s UP/DOWN ARROW button to move the traveler (the part on the belt or chain that the trolley engages with) to the up position (away from the door). 4 Push the wall station’s UP/DOWN ARROW button again. While the traveler is moving to the down position (toward the door), block the safety beam. THE TRAVELER MUST STOP, THEN REVERSE TO THE UP POSITION. The operator’s lights should fl ash three times. 5 Place an object in the path of the safety beam. Check that constant pressure is required on the wall station’s UP/DOWN ARROW button to cause the traveler to move toward the down position. Release the pushbutton before the operator stops; check that the traveler returns to the up position. ➤ NOTE: The garage door operator will not respond

SETTING THE CLOSE LIMIT

USE A SCREWDRIVER TO ADJUST THE CLOSE LIMIT

adjustment clockwise ¼-turn (towards UP on the label) to raise the close limit. 7 Activate the remote control. Wait for the door to move up a few feet, then activate the remote control again to stop the door. 8 Repeat Steps 5-7 until the close limit is properly adjusted. ➤ NOTE: If the door stops during opening or reverses

ENTER AN ACCESS CODE

PRESS THE WALL STATION'S UP/DOWN ARROW

- OR - - OR -

PRESS A REMOTE CONTROL BUTTON

AND PRESS START/STOP

UP DOWN

CLOSE LIMIT ADJUSTMENT

CHECKING FOR REVERSAL

excessive sprocket noise. Chain Adjustment If necessary, use the following steps to adjust the chain. 1 Hold the turnbuckle with a fl at blade screwdriver and loosen the two locknuts with a 7/16” end wrench. 2 Twist the turnbuckle to adjust the chain tension. Adjust the chain until the turnbuckle is sightly above the rail. 3 Hold the turnbuckle with a fl at blade screwdriver and tighten the two locknuts with a 7/16” end wrench.

ADJUSTING A CHAIN-DRIVE

TWIST TURNBUCKLE

THE TRAVELER MUST REVERSE WHEN THE BEAM IS INTERRUPTED

Closing the Door 1 With the door in view, press the wall station’s UP/ DOWN ARROW button or the button assigned to the operator on the remote control, or enter a valid access code and press START/STOP on a remote keypad. 2 When the operator is activated, the operator’s lights will turn on and the door will begin to close. 3 The door will close until the close limit is reached. If an obstacle is encountered (operator’s lights fl ash four times), or the safety beam is interrupted (operator’s lights fl ash three times) during closing, the door will stop, then re-open. 4 The operator’s lights will stay on for about fi ve minutes after the door stops.

CHAIN TIGHTEN CHAIN LOOSEN

during closing before reaching the limits, the door force adjustment needs to be set. Change the adjustment as described in the next section then return to this section to fi nish setting the limits.

TURNBUCKLE LOCKNUTS

DOWN

SAFETY LIGHTING

UP

BLOCK THE BEAM WHILE THE TRAVELER IS MOVING DOWN

LOCKNUTS

LOOSEN

TOWARD OPERATOR

TOWARD DOOR

TRAVELER

14 Testing & Adjusting the Door Force Safety System The door force adjustments are located on the side of the operator. The door force adjustments must be properly set at all times. The CLOSE FORCE adjustment controls how much force is required to cause the door to reverse direction if an obstruction is encountered during closing. The OPEN FORCE adjustment controls how much force is required to stop the door if an obstruction is encountered during opening.

HOLD TURNBUCKLE WITH FLAT BLADE SCREWDRIVER TO BACKUP LOCKNUTS

Belt Adjustment The tension spring in the traveler keeps the belt taut. The factory setting for the tension spring length is .9” long. If the tension spring is longer than 1”, adjust the belt. 1 Hold the traveler so the adjustment wheel is visible through the large slot. 2 Use a fl at blade screwdriver to turn the adjustment wheel to compress the tension spring until its length is between .9” and 1” long. Every Year Check the door hardware for lubrication needs. Lubricate door hinges, rollers and bearings according to door manufacturer’s recommended procedures.

TO HEAD LOCKNUTS

SETTING THE DOOR FORCE

TIGHTEN

CHECKING FORCED CLOSURE FEATURE

VERIFY THAT CONSTANT PRESSURE IS REQUIRED ON THE WALL STATION'S PUSHBUTTON TO MAKE THE TRAVELER GO DOWN

WHENEVER OPERATING, THE LIGHTS WILL TURN ON FOR ABOUT 5 MINUTES

NOTE: FLASHING LIGHTS INDICATE

ADJUSTING A BELT-DRIVE

MEASURE THE TENSION SPRING LENGTH

TROUBLE

ADJUSTMENT WHEEL

TRAVELER

to a CLOSE command from a radio transmitter if the safety beam is blocked. 6 To reconnect the operator, fl ip the release lever up. Raise the door manually until the operator reconnects.

ADJUSTING THE CLOSE FORCE

PLACE AN OBJECT IN THE BEAM'S PATH

WARNING Too much door force will interfere with the proper operation of the safety system. SOMEONE COULD BE SERIOUSLY INJURED OR KILLED IF THE DOOR FORCE IS SET TOO HIGH. A closing door might not reverse properly when required and someone could be pinned under it. An opening door might not stop when going up and someone hanging on the door could get pinned between the door and the header. Do not increase the door force beyond what is required to move the door. DO NOT USE THE DOOR FORCE ADJUSTMENT TO COMPENSATE FOR A BINDING OR STICKING GARAGE DOOR. PERFORM THE SAFETY REVERSAL SYSTEM TEST (STEPS 4-6) MONTHLY!

RELEASE PUSHBUTTON BEFORE THE OPERATOR STOPS, THE TRAVELER SHOULD RETURN TO THE UP POSITION

ADJUSTING THE OPEN FORCE

STOPPING THE DOOR

LOOSEN

WALL STATION

TIGHTEN

Stopping the Door Mid-travel 1 The door can be stopped immediately at any time by pressing the wall station’s UP/DOWN ARROW button, the remote control’s pushbutton, or press the START/STOP button on a remote keypad. 2 The next time the operator is activated, the door will move in the opposite direction.

REMOTE KEYPAD

TURN THE ADJUSTMENT WHEEL UNTIL THE TENSION SPRING IS ABOUT 1" LONG

12 Remote Controls The operator is supplied with a three-button remote control (the second and third buttons can be used to control an additional operator or gate if it contains a Linear MegaCode™ receiver). Additional single and multi-button remote controls can be purchased. An unlimited number of remote controls can be used with this operator. The short wire on the back of the operator serves as an antenna for the remote controls. Do not cut off the short wire or the remote controls will not operate well.

17 Troubleshooting

UNDER-SETTING THE CLOSE FORCE

DECREASE CLOSE FORCE ADJUSTMENT UNTIL THE DOOR REVERSES MIDWAY WHILE GOING DOWN

REMOTE CONTROL THE DOOR CAN BE STOPPED AT ANY POSITION USING THE WALL STATION, REMOTE CONTROL,

LAMPS FLASH TROUBLE CODEPROBLEMCAUSEREMEDY 1 FLASHNo problemRemote control entered into memoryAdd any additional remote controls (MegaCode™ type only) 2 FLASHESDoor won’t closeShorted wall station wiresCheck wall station wires. Be sure both are connected to the terminal screws. Check for a staple in the wall station wires. Remove any staples compressing the wire. 3 FLASHESDoor won’t closeSafety beam obstacleCheck for obstacles. Align the safety beam (Section 11) 4 FLASHESDoor reverses or won’t open or closeOpen or Close force exceeded, or motor thermal shutdownCheck for binding or un-balanced door. Adjust the door force (Section 14). If motor had thermal shutdown, wait 30 minutes and retry. 5 FLASHESDoor won’t open from transmitterRemote was activated while vacation switch was lockedUnlock vacation switch on wall station 6 FLASHESMotor ran longer than 30 secondsMechanical or electronic failureCall Technical Services Group for assistance

WARNING Children operating or playing with a garage door operator can injure themselves or others. The garage door could cause serious injury or death. Do not allow children to operate the remote control(s) or the wall station. A moving garage door could injure or kill someone under it. Activate the operator only when the door is clearly visible, free of obstructions and adjusted properly.

PREPARING TO ADD A REMOTE

OR A REMOTE KEYPAD

DECREASE

CLOSE FORCE

➤ NOTERead the following directions carefully before

Vacation Lock for Additional Security 1 Slide the wall station’s LOCK switch to the locked position to prevent remote controls from opening the door after the door is completely closed. The remotes can close the door, but not open it. The door can still be opened or closed by using the wall station’s UP/ DOWN ARROW pushbutton. ➤ NOTE: To signal that the vacation switch is locked,

setting the door force adjustments.

PREVENTING REMOTES FROM OPENING THE DOOR

PRESS THE LEARN BUTTON

LEARN LIGHT WILL GLOW FOR 15 SECONDS, REMOTE MUST BE ENTERED WHILE LEARN LIGHT IS ON

SETTING THE CLOSE FORCE

INCREASE CLOSE FORCE ADJUSTMENT UNTIL THE DOOR CLOSES FULLY WITHOUT REVERSING

To Add a Remote Control 1 Press the operator’s LEARN button. The red LEARN light will glow. The red light will stay on for about 15 seconds. A remote must be added while the red LEARN light is still on. 2 Send a signal from a remote. The red LEARN light and the operator’s lights will fl ash once indicating that the operator has accepted the remote. 3 Repeat Steps 1 & 2 for any additional remote controls. To Remove all Remote Controls 1 Press and hold the operator’s LEARN button for ten seconds or more. 2 Release the LEARN button. The red LEARN light will blink three times signaling that all of the remotes in the operator’s memory were erased. The red LEARN light will turn off, then turn on for 15 seconds. A remote control can be entered during this time using Step 2 above. Testing 1 Before testing the remote control, straighten out the operator’s short antenna wire so it points up. 2 Stand clear of the door, press the remote control’s button and verify that the operator starts. PRESS THE REMOTE CONTROL’S BUTTON AGAIN TO STOP THE DOOR MID-TRAVEL. 3 Set the open and close limits as described in the next section before any further testing. Replacing a Remote Control’s Batteries When the red light on the remote glows dimly, or fails to light at all when the remote is activated, the batteries need replacing. 1 Open the remote’s case and remove the circuit board 2 Replace old batteries with two Type 2032 batteries. 3 Re-assemble the remote.

Door Force Safety System Test 1 Start with the door open. Use the remote control to cycle the door during these tests. Adjusting the Close Force 2 Turn the CLOSE FORCE adjustment 1/8-turn at a time in the DECREASE direction (counterclockwise) until the door stops and reverses mid travel while going down. 3 Turn the CLOSE FORCE adjustment 1/8-turn at a time in the INCREASE direction (clockwise) until the door fully closes without reversing. Safety Reversal System Test 4 Lay a 2 x 4 board fl at on the fl oor where it will be struck by the center of the door as it closes. 5 Verify that the door reverses when it strikes the board. The door must reverse within two seconds after striking the board. ➤ NOTE: If the door stops after encountering the board

LOCK UNLOCK

ADDING A REMOTE

the operator’s lights will fl ash fi ve times if a remote is activated in an attempt to open the door. 2 Slide the wall station’s LOCK switch to the unlocked position to return the operator to normal operation.

SLIDE THE VACATION SWITCH DOWN TO LOCK (REMOTES DISABLED) OR UP TO UNLOCK (REMOTES NORMAL)

SEND A SIGNAL FROM A REMOTE

INCREASE

CLOSE FORCE

FCC NOTICE Changes or modifi cations not expressly described in this manual or approved by the manufacturer could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:

THE OPERATOR'S LIGHTS AND THE LEARN LIGHT WILL FLASH

ONCE WHEN THE REMOTE

ENTER A CODE AND PRESS START/STOP

HAS BEEN ACCEPTED

PRESS A BUTTON - OR -

CONTROLLING THE OPERATOR'S LIGHTS

TESTING THE SAFETY REVERSAL SYSTEM

Controlling the Operator’s Lights 1 The operator’s lights can be lit by pushing the wall station’s LIGHT button. The lights will remain on until the LIGHT button is pressed again or the operator is cycled. 2 If the operator’s lights are on, pushing the wall station’s LIGHT button will turn the operator’s lights off.

REMOVING ALL REMOTES

PRESS THE LEARN BUTTON FOR 10 SECONDS OR MORE

TEST WITH SMALL OBSTACLE

  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio/TV technician for help. LIMITED WARRANTY

THE DOOR MUST REVERSE WITHIN 2-SECONDS AFTER IMPACT WITH A 2 x 4 BOARD

PRESS THE LIGHT BUTTON TO TURN THE LIGHTS ON OR OFF

THE LIGHTS WILL STAY ON UNTIL THE LIGHT BUTTON IS PRESSED OR THE OPERATOR IS CYCLED

and does not reverse, the CLOSE FORCE needs to be DECREASED. 6 Repeat the Safety Reversal System Test until the door reverses within two seconds of striking the board. Adjusting the Open Force 7 Turn the OPEN FORCE adjustment 1/8-turn at a time in the DECREASE direction (counterclockwise) until the door stops mid travel while going up. 8 Turn the OPEN FORCE adjustment 1/8-turn at a time in the INCREASE direction (clockwise) until the door fully opens without stopping.

THE LEARN LIGHT WILL BLINK 3 TIMES SIGNALING THAT ALL REMOTES WERE REMOVED

This Linear product is warranted to the original consumer against defects in material and workmanship for: MODEL ELECTRONICS MECHANICAL MOTOR BELT LCO75 1 year 5 years Lifetime Lifetime

2 x 4 BOARD LAID FLAT UNDER CENTER OF DOOR

This product is warranted to the original consumer against defects in material and workmanship for the periods mentioned above. Linear will repair, or at its option, replace, any device that it fi nds requires service under this warranty, and will return the repaired or replaced device to the consumer at Linear’s cost. Devices must be sent to Linear for service at owner’s expense. This warranty does not apply to damage to the product from negligence, abuse, abnormal usage, misuse, accidents, normal wear or tear or due to failure to follow Seller’s instructions, or arising from improper installation, storage or maintenance. In no event will Linear be responsible for incidental, compensatory, punitive, consequential, indirect, special or other damages. The remedies provided by this warranty are exclusive. Some states do not allow the exclusion or limitation of incidental and consequential damages, so the above limitation or exclusion may not apply to you. Any warranties implied by law are limited to the time periods set forth above. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specifi c legal rights, and you may also have other rights which vary from state to state. For warranty service and shipping instructions contact Linear at the phone number shown below. In order to be protected by this warranty, save your proof of purchase and send a copy with equipment should repair be required. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.

REPLACING A REMOTE'S BATTERY

UNDER-SETTING THE OPEN FORCE SETTING THE OPEN FORCE

Disconnecting the Door from the Operator 1 With the door in any position (preferably closed), carefully pull the red release handle. USE CAUTION IF THE DOOR IS OPEN, THE DOOR MAY DROP. 2 The disconnected door can be opened or closed manually. 3 To re-connect the operator, fl ip the release lever up. Raise or lower the door manually until the operator reconnects.

IN CASE OF POWER FAILURE OR IF DOOR BECOMES OBSTRUCTED

1 TWIST DIME IN SLOT TO OPEN CASE

2 LIFT OFF THE TOP OF THE CASE

3 CAREFULLY REMOVE THE CIRCUIT BOARD

PULL THE RED RELEASE HANDLE TO DISCONNECT THE OPERATOR FROM THE DOOR

DECREASE

INCREASE

FLIP THE LEVER UP AND RAISE OR LOWER THE DOOR TO RECONNECT THE OPERATOR

OPEN FORCE

OPEN FORCE

5 INSERT TWO NEW TYPE 2032 BATTERIES PLUS SIDE UP THEN REASSEMBLE UNIT

IF DOOR BECOMES OBSTRUCTED,

PULL DOWN ON HANDLE

NOTICE

4 REMOVE OLD BATTERIES AND DISPOSE OF THEM PROPERLY

DECREASE OPEN FORCE ADJUSTMENT UNTIL THE DOOR STOPS MIDWAY WHILE GOING UP

INCREASE OPEN FORCE ADJUSTMENT UNTIL THE DOOR OPENS FULLY WITHOUT STOPPING

IF DOOR BECOMES OBSTRUCTED,

NOTICE

PULL DOWN ON HANDLE

Copyright © 2008 Linear LLC 228432 A

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
1 FLASHRemote control entered into memoryAdd any additional remote controls (MegaCode™ type only) p.2
2 FLASHESShorted wall station wiresCheck wall station wires. Be sure both are connected to the terminal screws. Check for a staple in the wall station wires. Remove any staples compressing the wire. p.2
3 FLASHESSafety beam obstacleCheck for obstacles. Align the safety beam (Section 11) p.2
4 FLASHESOpen or Close force exceeded, or motor thermal shutdownCheck for binding or un-balanced door. Adjust the door force (Section 14). If motor had thermal shutdown, wait 30 minutes and retry. p.2
5 FLASHESRemote was activated while vacation switch was lockedUnlock vacation switch on wall station p.2
6 FLASHESMechanical or electronic failureCall Technical Services Group for assistance p.2

Ask about the Linear LCO75

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Linear LCO75

Be the first to ask — other owners or our team will answer.

Original document

Linear LCO75 manual PDF

2 pages·906 KB·Garage Door Opener·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…