LINEAR LLC (760) 438-7000 USA & Canada (800) 835-5666 & (800) 421-1587
3 Locate the Header Bracket Position 1 Close the door. 2 From inside the garage, use a pencil to mark the vertical centerline of the door on the header wall and on the top panel of the door. 3 Examine the area above the center of the door on the door header wall for a header bracket mounting location. 4 Open the door to the high-rise point (the point where the top edge of the door is highest above the fl oor) and measure the distance to the fl oor. 5 Close the door and use a pencil to mark the header wall 1” above the measured high-rise point. ➤ NOTE: In some installations, the header bracket
9 Install the Door Bracket and Door Arm 1 Fully close the door. Hold the door bracket against the inside of the door’s top panel. Align the top edge of the bracket 2” to 4” below the top edge of the door; or, if there is a structural support across the top of the door, place the top edge of the bracket directly below the support. Align the vertical centerline drawn on the door with the center of the bracket. See the fi gure for details. Mark the left and right holes of the bracket. 2 Drill ¼” holes at marks and insert two ¼-20 x 2” carriage bolts (not supplied) from outside of door through the door bracket. 3 Secure door bracket with two ¼-20 keps nuts (not supplied). Tighten with a 7/16” socket. 4 Slide the 5/16” x 1-3/8” clevis pin through one hole on door bracket; then the single hole on the curved door arm; then through the other hole on the door bracket. Secure the clevis pin with the hitch pin. 5 Insert the single hole end of the straight door arm into the slot in the trolley. Slide the 1-1/8” clevis pin through the hole and secure it with a hitch pin. 6 Flip the trolley release lever to disconnect the trolley. 7 Rotate the curved door arm upward to meet the straight door arm connected to the trolley. Align the two door arms so that the holes in both arms overlap. ➤ NOTE: The straight door arm should be slightly angled
MARK THE CENTERLINE OF THE DOOR ON THE HEADER AND THE TOP DOOR PANEL
WARNING Children operating or playing with a garage door operator can injure themselves or others. The garage door could cause serious injury or death. Do not allow children to operate the remote control(s) or the wall station. Install the wall station out of reach of children and away from all moving parts of the door. The door must be clearly visible from the wall station. A moving garage door could injure someone under it. Only activate the door when it is properly adjusted, when it can be seen clearly and when there are no obstructions to the door travel.
Toll Free FAX (800) 468-1340
MODEL LCO75 LIGHT-DUTY CHAIN-DRIVE COMMERCIAL GARAGE DOOR OPERATOR RESIDENTIAL BELT-DRIVE/CHAIN-DRIVE GARAGE DOOR OPERATOR
ALIGN THE DOOR BRACKET ON THE CENTERLINE 2" TO 4"
BELOW THE TOP EDGE OF THE DOOR, OR DIRECTLY
BELOW ANY DOOR STRUCTURAL SUPPORT DRILL TWO 1/4" PILOT HOLES USE TWO 1/4-20 x 2" CARRIAGE BOLTS AND NUTS (NOT SUPPLIED) TO ATTACH THE DOOR BRACKET
beam wire is supplied with the operator, Use this wire or the installation’s pre-wiring. For additional wire, contact Linear for information regarding the 24-pack Model HAE00009 wire and wire clip kit. ➤ UL NOTE: All low voltage Class 2 cable used with this
MARKING ABOVE THE HIGH-RISE POINT
CONNECTING THE DOOR ARM TO THE DOOR BRACKET
MARK HEADER 1" ABOVE
CONNECT SINGLE-HOLE END OF DOOR ARM
location will be higher than the door header. This will require adding a 2x4 (or larger) cross piece to the wall studs to provide a mounting location for the header bracket. Use lag screws (not supplied) to attach the 2x4 to the studs. 6 On doors with low headroom, the header bracket can be attached to the ceiling up to 6” back from the header wall (see next step).
HIGH-RISE POINT
INSTALL HITCH PIN
Please read the instructions carefully! This garage door operator is designed to provide safe and reliable service if installed and tested as described in these instructions. A garage door is the largest mechanical appliance in a residence. Care must be taken to prevent injury or death during installation and operation of the garage door and garage door operator.
SAFETY NOTES IN THESE INSTRUCTIONS.
operator must be UL Listed Type CL2, CL2P, CL2R, or CL2X or other cable with equivalent or better electrical, mechanical, and fl ammability ratings. 1 Strip back ½” of insulation and connect a wire to each of the two terminals on the back of the wall station. 2 Use the screws provided to mount the wall station near an access door at a minimum height of fi ve feet. SEE IMPORTANT WARNING ABOVE! 3 For non-prewired installations, route the wire to the back of the operator. Use insulated staples (not supplied) to secure the wire. Staples must straddle both wires to avoid electrical shorts. 4 Cut the wall station wire about 6” longer than needed to reach the operator terminals. Strip back ½” of insulation. 5 Connect either wire to the operator’s PUSHBUTTON terminal and the other wire to the operator’s COMMON terminal. 6 Apply the User Safety Instruction Label (residential) to the wall next to the wall station in a prominent location. Use staples or tacks to help the label remain in place over time. 7 Install the Entrapment Warning Placard and Duty Rating Label (commercial) on the wall next to the door. Use screws to secure the placard to the wall. ➤ IMPORTANT! DO NOT PLUG THE OPERATOR IN AT
MOUNT WALL STATION AT LEAST 5 FEET ABOVE THE FLOOR LEVEL
DOOR
ARM
1-3/8" CLEVIS
SECTIONAL DOOR
PIN
MOUNTING THE WALL STATION
USE MACHINE SCREWS WHEN MOUNTING TO A SINGLE-GANG BOX
4 Install the Header Bracket 1 Hold the header bracket on the center line drawn above the door with the bottom edge of the bracket on the line marked above the high-rise point. 2 Use a pencil to mark the two bracket holes. 3 Drill two 3/16” pilot holes about 2” deep. 4 Use a ½” socket to fasten the bracket with two 5/16” x 2” lag screws.
ATTACHING THE HEADER BRACKET
USE WOOD SCREWS WHEN MOUNTING DIRECTLY TO WALL
1/2" SOCKET
CENTERLINE OF DOOR
ROUTE WIRE THROUGH SLOT IN CASE
TROLLEY
ATTACH HEADER BRACKET WITH TWO 5/16" x 2" LAG SCREWS
toward the operator head. 8 Line up door arms until trolley is positioned as shown. Connect the arms together using two 5/16-18 x 1” bolts inserted in the highest and lowest matching holes, secure the bolts with two 5/16” keps nuts, tighten with a ½” socket.
1 INCH (SECTIONAL)
PUT HOLE PLUGS IN TO HIDE SCREWS
IMPORTANT INSTALLATION SAFETY INSTRUCTIONS
INSTALL THE HITCH PIN
STRAIGHT DOOR ARM

THESE INSTALLATION SAFETY STEPS BEFORE PROCEEDING
5 Connect the Rail to the Header Bracket 1 Place assembled operator on the empty carton on the fl oor with rail towards the door. 2 Insert the end of the rail into header bracket. 3 Insert the 5/16” x 2-3/8” clevis pin through header bracket and rail. 4 Secure the clevis pin with the hitch pin.

1 READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS. 2 Install only on a properly balanced garage door. An improperly balanced door could result in severe injury or death. Repairs to cables, spring assemblies, and other hardware must be made by a qualifi ed service person before installing the operator. 3 Remove all pull ropes and remove, or make inoperative, all locks (unless mechanically and/or electrically interlocked to the power unit) that are connected to the door before installing the operator. Ropes connected to a garage door can cause entanglement and death. 4 If possible, install door operator 7 feet or more above the fl oor with the manual release handle mounted 6 feet above the fl oor. Instruct the end user on the operation of the manual release. 5 Do not connect the operator to the power source until instructed to do so. 6 Locate the wall station within sight of the door at a minimum height of 5 feet so that small children cannot reach it. Locate the wall station away from all moving parts of the door. 7 Residential Installations: Install the User Safety Label on the wall adjacent to the wall station. Commercial Installations: Install the Entrapment Warning Placard and Duty Rating Label in a prominent location visible in the area of the door. 8 Upon completion of the installation, the door must reverse when it comes in contact with a 1-1/2” high object (or a 2x4 laid fl at at the center of the door) on the fl oor and when the infrared safety beam is blocked. 9 Do not wear watches, rings or loose clothing while installing or servicing an operator. Jewelry or loose clothing can be caught in the mechanism of the garage door or the operator. 10 DISCONNECT THE ELECTRIC POWER FROM THE GARAGE DOOR OPERATOR BEFORE MAKING ANY REPAIRS OR REMOVING THE COVER. 11 Commercial Installations: The rate of operation must not exceed 13 cycles of opening and closing per hour.
LINE UP DOOR ARMS UNTIL TROLLEY IS POSITIONED AS SHOWN CONNECT ARMS WITH TWO 5/16-18 x 1" BOLTS IN THE HIGHEST AND LOWEST MATCHING HOLES
CONNECT THE WALL STATION WIRES TO PUSHBUTTON AND COMMON TERMINALS (EITHER WIRE TO EITHER TERMINAL)
10 Connect the Operator to Power Source
6 Hang the Operator Installation requirements vary with garage construction. Hanging brackets should be angled to provide rigid support. Hanging material is not provided. Angle iron and lag screws are recommended. DO NOT USE NAILS. Following are typical operator hanging methods. Certain installations will require improvised methods. 1 Raise the operator head and set it on top of a stepladder (use extra spacers on top of ladder if it isn’t tall enough). 2 Carefully open the door to the full up position. Lay a 2x4 across the top section of the door as a spacer. Adjust the operator height until the rail touches the spacer. The rail should be close to level. 3 Center the operator head and rail with the centerline mark on the top of the door. 4 For fi nished ceilings only: An angle iron cross piece between the two closest joists above the operator will be required. Mark mounting hole locations, drill pilot holes and attach the piece with two lag screws (not supplied). 5 Measure the distance from each of the operator’s hanging tabs to the ceiling joists or angle iron cross piece. 6 Cut two angle iron pieces to the required lengths for hanging brackets. Bend brackets if required. • For unfi nished ceilings: Hold each bracket in place
ASSEMBLE BRACKETS WITH 1/4-20 x 1/2" BOLTS AND KEPS NUTS
Cord and Outlet Connection The operator should be connected to a grounded receptacle on the ceiling or near the operator head. If none is available which will accept the grounded operator plug, one should be installed by a qualifi ed electrician. Do not use an extension cord. 1 Plug the operator into a grounded receptacle. 2 When the operator is plugged in, a click should sound in the operator and the lights should turn on. If the lights do not turn on, check the power source and light bulbs. Permanent Wiring SOME LOCAL ELECTRICAL CODES REQUIRE PERMANENT WIRING BETWEEN THE OPERATOR AND THE POWER SOURCE THROUGH A CONDUIT. IT IS RECOMMENDED THAT YOU HAVE A LICENSED ELECTRICAL CONTRACTOR FOLLOW THESE STEPS ONLY IF PERMANENT WIRING IS REQUIRED. 1 BE SURE POWER CORD IS UNPLUGGED. 2 Cut the power cord about 2” above the strain relief bushing on the operator. 3 Remove the four side screws and bottom cover of operator. 4 Use pliers to remove the strain relief bushing and discard the bushing. 5 Remove the outer insulation from the power cord and strip the white, black, and green wire insulation back about ½”. 6 Pull white (neutral), black (hot) and green (ground) wires through conduit. 7 Connect the conduit to the operator with the appropriate termination. 8 Use wire nuts (not supplied) to connect the wires to the matching color wires inside operator head. 9 Secure the wires away from all moving parts with a zip-tie as shown in the fi gure. 10 Replace the operator cover and the four side screws. 11 Connect the conduit wires to the power source at junction box. 12 When power is applied to the operator, a click should sound and the lights should turn on. If the lights do not turn on, check the power source, wiring, and light bulbs.
not be obstructed by the door, or by any part of the door hardware. Use wooden spacers between the beam brackets and wall if necessary to create proper clearance. 1 Assemble the two safety beam brackets from the four L-shaped brackets using two ¼-20 x ¾” bolts and ¼-20 keps nuts (one nut & bolt for each bracket).
POWERING THE OPERATOR
ADJUSTING OPERATOR HEIGHT
1 Check the Door Balance 1 From outside the garage, slowly open the door all the way, and then close it all the way. Notice if there is any binding, sticking or rubbing. The door should move smoothly in both directions. 2 Raise the garage door about halfway up. Carefully release the door and see if the door balances. It should stay in place. Close the door. ➤ IMPORTANT: If the garage door is unbalanced or
PLACE A 2x4 SPACER BETWEEN THE DOOR AND RAIL
LOCATE THE SAFETY BEAM BRACKETS SO THE BEAM CENTERLINE IS 6" ABOVE THE FLOOR
2 Position the assembled brackets on each side of the door so the center line of the safety beam lenses will be 6” above the fl oor. Use the index marks on the brackets to make the bracket assemblies equal lengths. Mark the locations for the bracket mounting screws (the brackets can be wall or fl oor mounted). ➤ NOTE: The safety beam receiver (the unit with two
INSTALLING THE BEAMS
ADJUST HEIGHT AS REQUIRED
THE DOOR SHOULD BALANCE WITHOUT GOING UP OR DOWN
indicators) should be located on the “shady” side of the door to prevent sunlight from shining directly into the receiver’s lens. 3 Drill two 3/16” pilot holes for lag screws at marks. Mount the brackets with two ¼” x 1-1/4” lag screws and tighten with a 7/16” socket (or use proper concrete fasteners if fl oor mounting). 4 Insert the sender and receiver into the bracket holes so the lenses of the units will face each other. Twist the units until the spring clips lock into a detent mark on the brackets. To protect the units from being bumped after installation, it is recommended to mount the sender and receiver inside the brackets as shown. 5 Install the two safety beam protective covers over the beam units to protect them from damage. ➤ IMPORTANT: Be careful to route the safety beam wiring
the door travel isn’t smooth, have a qualifi ed garage door professional adjust or repair the door.
and use a pencil to mark the locations where they will be attached to the joists, drill pilot holes and attach the pieces with two lag screws (not supplied). • For fi nished ceilings with an angle iron cross piece:
BE SURE THE POWER CORD IS UNPLUGGED!!
2 Attach the Rail to the Operator 1 Place the operator head on the garage fl oor with cardboard underneath it to protect the fi nish. 2 Manually turn the sprocket two full turns counterclockwise to align the trolley approximately 12 inches from the pulley bracket (see fi gure). 3 Align the rail over the center of the operator head. 4 Be sure the fl at on the sprocket lines up with the fl at on the drive shaft. 5 Slide the sprocket onto the shaft. 6 Attach the rail to the operator head by installing four ¼-20 x ¾” bolts. 7 Tighten the four bolts in the order shown with a 7/16” socket.
TWIST UNIT TO LOCK INTO BRACKET
SET TROLLEY LOCATION
INSERT UNIT INTO BRACKET
CUT THE CORD ABOUT 2" ABOVE THE STRAIN RELIEF BUSHING
Attach the two hanging brackets to the cross piece with two bolts and two keps nuts (not supplied). 7 Attach operator to hanging brackets using two 5/16-18 x 1” hex bolts and two 5/16-18 keps nuts (supplied). Insert bolts from the inside of hanger brackets with the nuts on the outside of the operator. Tighten nuts with a ½” socket. 8 When using a 12-foot or longer I-rail, install the center rail support bracket at the middle of the rail. The bracket attaches with a strap (not included) to a vertical support. 9 Tighten all hanging hardware. 10 Open and close the door manually. The door should clear the rail by at least 1”. 11 Attach the trolley’s release lever to the red release handle with the cord supplied so the handle is at least 6 feet from the fl oor. Cut off any excess cord. 12 Press the light cover release tabs in to open the covers. Install two 100 watt maximum rough service lamps. Swing the light covers closed, snapping them shut.
SET TROLLEY 12" FROM PULLEY BRACKET
PRE-ADJUSTING THE BEAMS
ALIGNING THE RAIL
LINE UP THE RAIL OVER THE DRIVE SHAFT ON TOP OF THE OPERATOR HEAD
ADJUST UNITS SO LENSES POINT TOWARD EACH OTHER
FOR PERMANENT WIRING ONLY!
SPRING CLIP LATCHES INTO DETENT MARKS TO HOLD UNIT'S POSITION
away from any moving parts of the door or operator. 6 For non-prewired installations, route the wires from the sender and receiver, up the wall above the door hardware, then over to the center of the door, then along the top of the rail (or ceiling), and back to the operator head. Cut the wires about 6” longer than needed to reach the operator terminals. Strip back ½” of insulation from the ends of the wires. 7 For non-prewired installations, secure all the wires to the wall and ceiling with insulated staples (not supplied). Staples must straddle both wires to prevent shorts. Secure the wire to the top of the rail with wire clips (supplied). 8 At the operator, twist one wire from each pair together, then twist the other wire from each pair together. 9 Attach either twisted connection to the operator’s BEAM terminal. Connect the other twisted connection to the operator’s COMMON terminal.
BE SURE THE FLAT ON THE SPROCKET LINES UP WITH THE FLAT ON THE DRIVE SHAFT

HANG THE OPERATOR WITH TWO 5/16-18 x 1" BOLTS AND NUTS
INSTALLING THE BEAM COVERS
MATING THE SPROCKET AND SHAFT
COVER SNAPS ONTO BRACKET WITH FOUR TABS
THE PROTECTIVE COVER CAN ATTACH TO EITHER SIDE OF THE BRACKET
TABS FIT INTO SLOTS
BELT DRIVE
FOR PERMANENT WIRING ONLY!
ATTACHING THE RAIL
TIGHTEN THE RAIL-TO-HEAD BOLTS IN THIS ORDER
CONNECTING THE BEAM WIRES
BEAM WIRES
HARDWIRING THE OPERATOR
CONDUIT WIRE NUTS
ATTACH THE SUPPORT BRACKET AT THE CENTER OF THE RAIL
INSTALL FOUR 1/4-20 x 3/4" RAIL-TO-HEAD BOLTS USING A 7/16" SOCKET (SEE TORQUE ORDER BELOW)
CONNECT CONDUIT WIRING TO OPERATOR WIRING WITH WIRE NUTS
PULL THE CHAIN OR BELT AWAY FROM THE RAIL TO FIT THE SOCKET ON THE FRONT BOLTS
GREEN - GROUND WHITE - NEUTRAL BLACK - HOT
CONNECT THE SAFETY BEAM WIRES TO COMMON AND BEAM TERMINALS (EITHER WIRE TO EITHER TERMINAL)
12"

11 Aligning the Infrared Safety Beam The safety beam has two components, a sender and a receiver. The sender produces a narrow infrared beam that travels across the bottom of the door opening to the infrared receiver. If an object blocks the infrared beam while the door is closing, the door will stop, then reverse and fully open (the operator’s light will fl ash three times). As a safety feature, the operator will ignore signals from all remote controls if the door is open and the infrared safety beam is blocked or out of alignment. In this case, the door can be forced closed by pressing and holding the wall station’s up/down arrow pushbutton (be sure the door area is in clear view).
13 Adjusting the Open and Close Limits The limit adjustments that control how far the door will open or close are located on the side of the operator. The limits should be adjusted so the door opens just short of any door stops, and closes right at the fl oor level. Each full turn of a limit adjustment equals about 2-½” of door travel.
16 Garage Door Operator Maintenance Weather conditions may affect the door operation which could require some re-setting of the operator’s adjustments. Doors may swell and become heavier during wet periods, door hinges and rollers might bind during cold periods. To insure safe operation of the door, perform the following tests, including any additional test steps described. Every Month 1 With the door closed, pull the red release handle to disconnect the operator from the door. 2 From outside the garage, slowly open the door manually all the way, and then close it all the way. Notice if there is any binding, sticking or rubbing. The door should move smoothly in both directions. 3 Raise the garage door about halfway up. Carefully release the door and see if the door balances. It should stay in place. Close the door. ➤ NOTE: If the garage door is unbalanced or the
IMPORTANT USER SAFETY INSTRUCTIONS
DOWN UP
WARNING A MOVING GARAGE DOOR CAN CAUSE INJURY OR DEATH!
1 READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS. 2 NEVER LET CHILDREN OPERATE, OR PLAY WITH DOOR CONTROLS! KEEP REMOTE CONTROL AWAY FROM CHILDREN! 3 Always keep moving door in sight and away from people and objects until it is completely closed. NO ONE SHOULD CROSS THE PATH OF THE MOVING DOOR. 4 NEVER GO UNDER A STOPPED, PARTIALLY OPEN DOOR. 5 Test door operator monthly. The garage door MUST reverse on contact with a 1-1/2 inch object (or a 2x4 board laid fl at at the center of the door) on the fl oor. If adjusting either the force or the limit of travel, re-test the door operator. Failure to adjust the operator properly may cause severe injury or death. 6 If possible, use the red emergency release handle only when the door is closed. Use caution when using this release with the door open. Weak or broken springs may cause the door to fall rapidly, causing injury or death. 7 KEEP GARAGE DOORS PROPERLY BALANCED. (See Garage Door Operator Maintenance) An improperly balanced door could cause severe injury or death. Have a qualifi ed service person make repairs to cables, spring assembly and other hardware.
USE A SCREWDRIVER TO ADJUST THE OPEN LIMIT
Safety Beam Test 1 Check that the operator has power. The green lights on the sender and receiver should be lit. 2 If the receiver’s green light is on, but the red light is off, the receiver has power but is not detecting the infrared beam from the sender. The red light might fl ash when the beam is partially detected. This can be caused by mis-alignment or something blocking the beam. Adjust the safety beam sender and receiver while watching the receiver’s red light (stay out of the beam while aligning it). When the red light stays on, the beam is aligned.
1 Activate the remote control. Wait while the door moves to the open position and stops. 2 Examine the position of the door. • If the door needs to open more, turn the OPEN LIMIT
adjustment clockwise ¼-turn (towards UP on the label) to raise the open limit. • If the door needs to open less, turn the OPEN LIMIT
GREEN LIGHT ON = POWER ON OFF = POWER OFF
adjustment counterclockwise ¼-turn (towards DOWN on the label) to lower the open limit. 3 Activate the remote control. Wait for the door to move down a few feet, then activate the remote control again to stop the door. 4 Repeat Steps 1-3 until the open limit is properly adjusted. 5 Activate the remote control. Wait while the door moves to the closed position and stops. 6 Examine the position of the door. • If the door needs to close more, turn the CLOSE
RED LIGHT ON = BEAM ALIGNED, NO OBSTRUCTION OFF = BEAM NOT ALIGNED, OR OBSTRUCTION BLINKING = BEAM NEEDS BETTER ALIGNMENT
TO DISCONNECT OPERATOR
TO RECONNECT OPERATOR
8 SAVE THESE INSTRUCTIONS.
Opening the Door 1 With the door in view, press the wall station’s UP/ DOWN ARROW button or the button assigned to the operator on the remote control, or enter a valid access code and press START/STOP on a remote keypad. 2 When the operator is activated, the operator’s lights will turn on and the door will begin to open. 3 The door will open until the open limit is reached. If an obstacle is encountered (operator’s lights fl ash four times) while the door is opening, the door will stop. 4 The operator’s lights will stay on for about fi ve minutes after the door stops.
PULL THE RED RELEASE HANDLE TO DISCONNECT THE OPERATOR FROM THE DOOR
OPENING OR CLOSING THE DOOR
UP
FLIP THE LEVER UP AND RAISE OR LOWER THE DOOR TO RECONNECT THE OPERATOR
ADJUST THE SENDER AND RECEIVER UNTIL THE RED INDICATOR LIGHTS SOLID
IF DOOR BECOMES OBSTRUCTED,
PULL DOWN ON HANDLE
NOTICE
REMOTE KEYPAD
IF DOOR BECOMES OBSTRUCTED,
PULL DOWN ON HANDLE
NOTICE
LIMIT adjustment counterclockwise ¼-turn (towards DOWN on the label) to lower the close limit. • If the door needs to close less, turn the CLOSE LIMIT
for: 1) Dirt on the receiver’s lens, 2) Sunlight shining into the receiver’s lens, 3) A short in the safety beam wiring (from staples or at the operator terminals). 3 With the door closed and the operator disengaged from the door, press the wall station’s UP/DOWN ARROW button to move the traveler (the part on the belt or chain that the trolley engages with) to the up position (away from the door). 4 Push the wall station’s UP/DOWN ARROW button again. While the traveler is moving to the down position (toward the door), block the safety beam. THE TRAVELER MUST STOP, THEN REVERSE TO THE UP POSITION. The operator’s lights should fl ash three times. 5 Place an object in the path of the safety beam. Check that constant pressure is required on the wall station’s UP/DOWN ARROW button to cause the traveler to move toward the down position. Release the pushbutton before the operator stops; check that the traveler returns to the up position. ➤ NOTE: The garage door operator will not respond
adjustment clockwise ¼-turn (towards UP on the label) to raise the close limit. 7 Activate the remote control. Wait for the door to move up a few feet, then activate the remote control again to stop the door. 8 Repeat Steps 5-7 until the close limit is properly adjusted. ➤ NOTE: If the door stops during opening or reverses
PRESS THE WALL STATION'S UP/DOWN ARROW
- OR - - OR -
PRESS A REMOTE CONTROL BUTTON
AND PRESS START/STOP
UP DOWN
CLOSE LIMIT ADJUSTMENT
CHECKING FOR REVERSAL
excessive sprocket noise. Chain Adjustment If necessary, use the following steps to adjust the chain. 1 Hold the turnbuckle with a fl at blade screwdriver and loosen the two locknuts with a 7/16” end wrench. 2 Twist the turnbuckle to adjust the chain tension. Adjust the chain until the turnbuckle is sightly above the rail. 3 Hold the turnbuckle with a fl at blade screwdriver and tighten the two locknuts with a 7/16” end wrench.
TWIST TURNBUCKLE
THE TRAVELER MUST REVERSE WHEN THE BEAM IS INTERRUPTED
Closing the Door 1 With the door in view, press the wall station’s UP/ DOWN ARROW button or the button assigned to the operator on the remote control, or enter a valid access code and press START/STOP on a remote keypad. 2 When the operator is activated, the operator’s lights will turn on and the door will begin to close. 3 The door will close until the close limit is reached. If an obstacle is encountered (operator’s lights fl ash four times), or the safety beam is interrupted (operator’s lights fl ash three times) during closing, the door will stop, then re-open. 4 The operator’s lights will stay on for about fi ve minutes after the door stops.
during closing before reaching the limits, the door force adjustment needs to be set. Change the adjustment as described in the next section then return to this section to fi nish setting the limits.
DOWN
SAFETY LIGHTING
UP
BLOCK THE BEAM WHILE THE TRAVELER IS MOVING DOWN
LOOSEN
TOWARD OPERATOR
TOWARD DOOR
TRAVELER
14 Testing & Adjusting the Door Force Safety System The door force adjustments are located on the side of the operator. The door force adjustments must be properly set at all times. The CLOSE FORCE adjustment controls how much force is required to cause the door to reverse direction if an obstruction is encountered during closing. The OPEN FORCE adjustment controls how much force is required to stop the door if an obstruction is encountered during opening.
HOLD TURNBUCKLE WITH FLAT BLADE SCREWDRIVER TO BACKUP LOCKNUTS
Belt Adjustment The tension spring in the traveler keeps the belt taut. The factory setting for the tension spring length is .9” long. If the tension spring is longer than 1”, adjust the belt. 1 Hold the traveler so the adjustment wheel is visible through the large slot. 2 Use a fl at blade screwdriver to turn the adjustment wheel to compress the tension spring until its length is between .9” and 1” long. Every Year Check the door hardware for lubrication needs. Lubricate door hinges, rollers and bearings according to door manufacturer’s recommended procedures.
SETTING THE DOOR FORCE
TIGHTEN
CHECKING FORCED CLOSURE FEATURE
VERIFY THAT CONSTANT PRESSURE IS REQUIRED ON THE WALL STATION'S PUSHBUTTON TO MAKE THE TRAVELER GO DOWN
WHENEVER OPERATING, THE LIGHTS WILL TURN ON FOR ABOUT 5 MINUTES
ADJUSTING A BELT-DRIVE
MEASURE THE TENSION SPRING LENGTH
TROUBLE
ADJUSTMENT WHEEL
TRAVELER
to a CLOSE command from a radio transmitter if the safety beam is blocked. 6 To reconnect the operator, fl ip the release lever up. Raise the door manually until the operator reconnects.
PLACE AN OBJECT IN THE BEAM'S PATH
WARNING Too much door force will interfere with the proper operation of the safety system. SOMEONE COULD BE SERIOUSLY INJURED OR KILLED IF THE DOOR FORCE IS SET TOO HIGH. A closing door might not reverse properly when required and someone could be pinned under it. An opening door might not stop when going up and someone hanging on the door could get pinned between the door and the header. Do not increase the door force beyond what is required to move the door. DO NOT USE THE DOOR FORCE ADJUSTMENT TO COMPENSATE FOR A BINDING OR STICKING GARAGE DOOR. PERFORM THE SAFETY REVERSAL SYSTEM TEST (STEPS 4-6) MONTHLY!
RELEASE PUSHBUTTON BEFORE THE OPERATOR STOPS, THE TRAVELER SHOULD RETURN TO THE UP POSITION
STOPPING THE DOOR
LOOSEN
WALL STATION
TIGHTEN
Stopping the Door Mid-travel 1 The door can be stopped immediately at any time by pressing the wall station’s UP/DOWN ARROW button, the remote control’s pushbutton, or press the START/STOP button on a remote keypad. 2 The next time the operator is activated, the door will move in the opposite direction.
TURN THE ADJUSTMENT WHEEL UNTIL THE TENSION SPRING IS ABOUT 1" LONG
12 Remote Controls The operator is supplied with a three-button remote control (the second and third buttons can be used to control an additional operator or gate if it contains a Linear MegaCode™ receiver). Additional single and multi-button remote controls can be purchased. An unlimited number of remote controls can be used with this operator. The short wire on the back of the operator serves as an antenna for the remote controls. Do not cut off the short wire or the remote controls will not operate well.
DECREASE CLOSE FORCE ADJUSTMENT UNTIL THE DOOR REVERSES MIDWAY WHILE GOING DOWN
REMOTE CONTROL THE DOOR CAN BE STOPPED AT ANY POSITION USING THE WALL STATION, REMOTE CONTROL,
WARNING Children operating or playing with a garage door operator can injure themselves or others. The garage door could cause serious injury or death. Do not allow children to operate the remote control(s) or the wall station. A moving garage door could injure or kill someone under it. Activate the operator only when the door is clearly visible, free of obstructions and adjusted properly.
OR A REMOTE KEYPAD
DECREASE
CLOSE FORCE
Vacation Lock for Additional Security 1 Slide the wall station’s LOCK switch to the locked position to prevent remote controls from opening the door after the door is completely closed. The remotes can close the door, but not open it. The door can still be opened or closed by using the wall station’s UP/ DOWN ARROW pushbutton. ➤ NOTE: To signal that the vacation switch is locked,
setting the door force adjustments.
LEARN LIGHT WILL GLOW FOR 15 SECONDS, REMOTE MUST BE ENTERED WHILE LEARN LIGHT IS ON
INCREASE CLOSE FORCE ADJUSTMENT UNTIL THE DOOR CLOSES FULLY WITHOUT REVERSING
To Add a Remote Control 1 Press the operator’s LEARN button. The red LEARN light will glow. The red light will stay on for about 15 seconds. A remote must be added while the red LEARN light is still on. 2 Send a signal from a remote. The red LEARN light and the operator’s lights will fl ash once indicating that the operator has accepted the remote. 3 Repeat Steps 1 & 2 for any additional remote controls. To Remove all Remote Controls 1 Press and hold the operator’s LEARN button for ten seconds or more. 2 Release the LEARN button. The red LEARN light will blink three times signaling that all of the remotes in the operator’s memory were erased. The red LEARN light will turn off, then turn on for 15 seconds. A remote control can be entered during this time using Step 2 above. Testing 1 Before testing the remote control, straighten out the operator’s short antenna wire so it points up. 2 Stand clear of the door, press the remote control’s button and verify that the operator starts. PRESS THE REMOTE CONTROL’S BUTTON AGAIN TO STOP THE DOOR MID-TRAVEL. 3 Set the open and close limits as described in the next section before any further testing. Replacing a Remote Control’s Batteries When the red light on the remote glows dimly, or fails to light at all when the remote is activated, the batteries need replacing. 1 Open the remote’s case and remove the circuit board 2 Replace old batteries with two Type 2032 batteries. 3 Re-assemble the remote.
Door Force Safety System Test 1 Start with the door open. Use the remote control to cycle the door during these tests. Adjusting the Close Force 2 Turn the CLOSE FORCE adjustment 1/8-turn at a time in the DECREASE direction (counterclockwise) until the door stops and reverses mid travel while going down. 3 Turn the CLOSE FORCE adjustment 1/8-turn at a time in the INCREASE direction (clockwise) until the door fully closes without reversing. Safety Reversal System Test 4 Lay a 2 x 4 board fl at on the fl oor where it will be struck by the center of the door as it closes. 5 Verify that the door reverses when it strikes the board. The door must reverse within two seconds after striking the board. ➤ NOTE: If the door stops after encountering the board
ADDING A REMOTE
the operator’s lights will fl ash fi ve times if a remote is activated in an attempt to open the door. 2 Slide the wall station’s LOCK switch to the unlocked position to return the operator to normal operation.
SLIDE THE VACATION SWITCH DOWN TO LOCK (REMOTES DISABLED) OR UP TO UNLOCK (REMOTES NORMAL)
INCREASE
CLOSE FORCE
FCC NOTICE Changes or modifi cations not expressly described in this manual or approved by the manufacturer could void the user’s authority to operate the equipment. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
THE OPERATOR'S LIGHTS AND THE LEARN LIGHT WILL FLASH
ENTER A CODE AND PRESS START/STOP
HAS BEEN ACCEPTED
PRESS A BUTTON - OR -
CONTROLLING THE OPERATOR'S LIGHTS
TESTING THE SAFETY REVERSAL SYSTEM
Controlling the Operator’s Lights 1 The operator’s lights can be lit by pushing the wall station’s LIGHT button. The lights will remain on until the LIGHT button is pressed again or the operator is cycled. 2 If the operator’s lights are on, pushing the wall station’s LIGHT button will turn the operator’s lights off.
PRESS THE LEARN BUTTON FOR 10 SECONDS OR MORE
THE DOOR MUST REVERSE WITHIN 2-SECONDS AFTER IMPACT WITH A 2 x 4 BOARD
PRESS THE LIGHT BUTTON TO TURN THE LIGHTS ON OR OFF
THE LIGHTS WILL STAY ON UNTIL THE LIGHT BUTTON IS PRESSED OR THE OPERATOR IS CYCLED
and does not reverse, the CLOSE FORCE needs to be DECREASED. 6 Repeat the Safety Reversal System Test until the door reverses within two seconds of striking the board. Adjusting the Open Force 7 Turn the OPEN FORCE adjustment 1/8-turn at a time in the DECREASE direction (counterclockwise) until the door stops mid travel while going up. 8 Turn the OPEN FORCE adjustment 1/8-turn at a time in the INCREASE direction (clockwise) until the door fully opens without stopping.
THE LEARN LIGHT WILL BLINK 3 TIMES SIGNALING THAT ALL REMOTES WERE REMOVED
This Linear product is warranted to the original consumer against defects in material and workmanship for: MODEL ELECTRONICS MECHANICAL MOTOR BELT LCO75 1 year 5 years Lifetime Lifetime
2 x 4 BOARD LAID FLAT UNDER CENTER OF DOOR
This product is warranted to the original consumer against defects in material and workmanship for the periods mentioned above. Linear will repair, or at its option, replace, any device that it fi nds requires service under this warranty, and will return the repaired or replaced device to the consumer at Linear’s cost. Devices must be sent to Linear for service at owner’s expense. This warranty does not apply to damage to the product from negligence, abuse, abnormal usage, misuse, accidents, normal wear or tear or due to failure to follow Seller’s instructions, or arising from improper installation, storage or maintenance. In no event will Linear be responsible for incidental, compensatory, punitive, consequential, indirect, special or other damages. The remedies provided by this warranty are exclusive. Some states do not allow the exclusion or limitation of incidental and consequential damages, so the above limitation or exclusion may not apply to you. Any warranties implied by law are limited to the time periods set forth above. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. This warranty gives you specifi c legal rights, and you may also have other rights which vary from state to state. For warranty service and shipping instructions contact Linear at the phone number shown below. In order to be protected by this warranty, save your proof of purchase and send a copy with equipment should repair be required. All products returned for warranty service require a Return Product Authorization Number (RPA#). Contact Linear Technical Services at 1-800-421-1587 for an RPA# and other important details.
UNDER-SETTING THE OPEN FORCE SETTING THE OPEN FORCE
Disconnecting the Door from the Operator 1 With the door in any position (preferably closed), carefully pull the red release handle. USE CAUTION IF THE DOOR IS OPEN, THE DOOR MAY DROP. 2 The disconnected door can be opened or closed manually. 3 To re-connect the operator, fl ip the release lever up. Raise or lower the door manually until the operator reconnects.
IN CASE OF POWER FAILURE OR IF DOOR BECOMES OBSTRUCTED
2 LIFT OFF THE TOP OF THE CASE
3 CAREFULLY REMOVE THE CIRCUIT BOARD
PULL THE RED RELEASE HANDLE TO DISCONNECT THE OPERATOR FROM THE DOOR
INCREASE
FLIP THE LEVER UP AND RAISE OR LOWER THE DOOR TO RECONNECT THE OPERATOR
OPEN FORCE
5 INSERT TWO NEW TYPE 2032 BATTERIES PLUS SIDE UP THEN REASSEMBLE UNIT
PULL DOWN ON HANDLE
NOTICE
4 REMOVE OLD BATTERIES AND DISPOSE OF THEM PROPERLY
DECREASE OPEN FORCE ADJUSTMENT UNTIL THE DOOR STOPS MIDWAY WHILE GOING UP
INCREASE OPEN FORCE ADJUSTMENT UNTIL THE DOOR OPENS FULLY WITHOUT STOPPING
NOTICE
PULL DOWN ON HANDLE
Copyright © 2008 Linear LLC 228432 A
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| 1 FLASH | Remote control entered into memory | Add any additional remote controls (MegaCode™ type only) | p.2 |
| 2 FLASHES | Shorted wall station wires | Check wall station wires. Be sure both are connected to the terminal screws. Check for a staple in the wall station wires. Remove any staples compressing the wire. | p.2 |
| 3 FLASHES | Safety beam obstacle | Check for obstacles. Align the safety beam (Section 11) | p.2 |
| 4 FLASHES | Open or Close force exceeded, or motor thermal shutdown | Check for binding or un-balanced door. Adjust the door force (Section 14). If motor had thermal shutdown, wait 30 minutes and retry. | p.2 |
| 5 FLASHES | Remote was activated while vacation switch was locked | Unlock vacation switch on wall station | p.2 |
| 6 FLASHES | Mechanical or electronic failure | Call Technical Services Group for assistance | p.2 |
Owners and our team usually reply within a day — and your question helps the next person too.