For Home and Office Use Tested to Comply with FCC Standards
© LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - EDITION 1.1 (DEC 08)



For Home and Office Use Tested to Comply with FCC Standards
© LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - EDITION 1.0 (DEC-08)

2.2 Connection and commissioning Close the antenna and power supply, or the cold-service cable to the corresponding connections on the rear side of the appliance. Then connect them to the Network Time Server by network cable with your network or close the Network Time Server with the aid of the supplied serial cable to a seral interface.



2.3 Display After being switched on, the set configuration and firmware version appear for a few seconds on the LCD display. Then the IP address of Network Time Server. After that, the display shows time and date. The Network Time Server is initially in quartz operation. In addition to the time, "quartz" is blended during quartz operation. During this time, the Network Time Server Already fully operational. After about two minutes, the Network Time Server with a correspondingly good reception into radio operation. The display then changes from “quartz” to “ok F=...” and the radio time LED lights up green. The number behind the “F=” indicates the number of bit errors in the last ten minutes.
2.4 Alignment of the antenna The reception quality of the long wave signals can be influenced by local conditions. Obstacles such as reinforced concrete or mountains weaken the signal, effects of motors and monitors can disturb the amplitude-modulated signal. In the development of Network Time Servers particular emphasis was placed on disturbance sensitivity. Thanks to active long wavelene antenna and refined filter technology, the device works both at a great distance from the transmitter as well as in an electromagnetically disturbed environment.



3.1 Network Time Server as an SNTP server The integrated Ethernet interface can be used to Network Time Server You can connect to your network and act as a stand-alone time server. The Network Time Server uses the SNTP protocol, which is available for synchronization under various operating systems. So you can with one of them. Network Time Server Synchronize time on all clients of your network
3.2.1 Windows XP and Vista If you want to synchro-nize your PCClock on Windows XP or Vista, you don’t need any additional program me. First, call the date and time properties by double-clicking on the time displayed in the taskbar. Now click on the tab Internet time and carry the IP address of your Network Time Servers into the incoming field Servers (see Figure 1). 1). With the button Update now You can test the synchronization. Close the settings of date and time with one click OK ab. Windows now automatically syncs over the Network Time Server.


3.2.2 Windows 9x/NT/2000 Under Windows 9x/NT/2000, the PC watch is easiest to use with the freeware program Dimension 4 (D4) synchronize over the network. D4 is on the driver CD under “tools\d4”. Start the installation by starting D4's setup file. With the button Update now You can test the synchronization. Close the settings of date and time with one click OK ab. Windows now automatically syncs over the Network Time Server.

To your computer with the Network Time Server To synchronize, click on the button Added. Now wear them under Servers the IP address of Network Time Servers and below Location the location or any name. Select “SNTP” for the protocol. Confirm your entries with one click OK (see Figure 1). 2). In the default settings, D4 will match your computer time once per hour.
3.2.3. Linux On Linux, there are many ways to match its system time over network. This section shows how you can use ntpdate and crone Synchronize your system time regularly. First, check if ntpdate It is on your computer. Give them the command.which ntpdate“Into the Linux console.” If ntpdate is installed on your computer, reports which The path under which ntpdate is stored. (FIG. 1). 3.)


Provided which No path out, you should ntpdate Install (included in the NTP package). The shell script make all.sh For installation, see the driver CD under “EMC Professional NET\tools\linux\get ntp”. Further information about the installation can be found in chapter 4.2. You synchronize your system time by using the command "ntpdate" <IP address of the Network Time Server>“Write to the console.” If you only want the time of Network Time Servers query and do not match the system time, then use the parameter "-q“.

In order for the system time to be regularly matched, a Cronjob are created. One Cronjob is one of crone executed command. For this purpose, it is recommended that ntpdate with the parameter ‘-s“ to start.” This parameter is used to output the console from ntpdate written in the system log. By one Cronjob To create, you must crontab With the order “crontab -e Opening.

Figure 5 shows a cronjob entry in which the script sync emc.sh is executed once at the full hour.

3.3 IP Access Control List The IP Access Control List (IP ACL) provides an IP filter for your Network Time Server in this case. If the filter is active, only hosts and subnetworks whose IP addresses are entered in the following list can contact Network Time Server record, change settings and receive time signals. Example: „http://192.168.0.1“ or „http://192.168.0.1/24“ If you have accidentally "locked out" here, activate the Network Time Server in bootloader mode and deactivate with the help of GBL Conf.exe.exes IP ACL. The settings of the IP ACL can be found in chapter 5.3. 4 Operation by serial interface

The Network Time Server offers a serial connection in addition to the Ethernet port. For Windows, the driver software is w32EMC attached to the supplied CD-ROM. For Linux, you need the free software package NTP.
4.1 Operation under Windows 4.1.1 Installation of the software Insert the CD with driver software into your CD-ROM drive. Start the file “setup w32EMC.exe Follow the instructions of the installation program. The required files are copied to the directory of disk you have chosen. Start the driver w32EMC.exe. First, the COM port used must be set. After successful installation, the system time of the PC is synchronized regularly.

4.1.3 Program interface The following values are displayed in the software window: DCF77 status system time Here the day of the week, date and current time of the PC (local time) is displayed. Last reception Here the last error-free DCF77 prototype is displayed (day of week, date and time). At this time, the last synchronization took place. Operation mode Here the operating mode of Network Time Servers displayed (“quartz operation” or “radio operation”). ‘radio operations’ means: means that the Network Time Server receives the DCF77 time signal in a selective quality.


‘Quarz operation’ means: means: Network Time Server has switched to the built-in quartz watch, because no DCF77 protocol can be received at present or the signal contains too many bit errors. The Network Time Server Often in quartz mode, the orientation of the antenna should be improved (see chapter 2.4). Faulty bits Here, the number of incorrectly received bits is displayed. The Network Time Server switches to quartz operation if too many faulty bits have been received. During operation, a maximum of 40 bit errors within ten minutes are allowed. As soon as less than 40 bit errors occur within ten minutes, the Network Time Server back to radio operation. You can also read the number of bit errors in the LCD display on the “F=...” indicator. Announcements Here the announcements of the DCF77 transmitter are displayed (e.g. the change from summer to normal time or an announcement of a leap second. V.24 V.22Status Here the status of data transmission is displayed on the serial interface: ‘active’ FIG. ‘active’ in ... Seconds: The time telegram is received at the interface and matched to the system time of the PC. “No reception!”: No time telegram is received on the selected interface. Check that the correct interface is selected and whether the receiver is connected to the PC correctly. ‘no COM port selected’: No interface has been selected yet. Interface Here the selected interface is displayed. Log The last received time telegram of the Network Time Servers is output as ASCII text.

4.1.4 Logging The software of Network Time Servers offers you the ability to log all actions performed and advanced error messages during operation. This is for administrative purposes or, if necessary, particularly helpful for error detection. You can activate the log operation at program start. This is done with the so-called "seal". Command line parameters ‘-l‘. You can use this parameter e.g. Indicate in an MS-DOS request (indicated)‘c:\programme\EMCprof>w32EMC –l’ or extend the shortcut in your Start Menu by this parameter. If the parameter transfer is accepted by the software, a “-l“ indicated”. In log operation, all output protocols are transferred to the file logfile.emc written. You will find this file in the program directory, where it also w32EMC.exe is located.
4.2 Operation under Linux (NTP) The Network Time Server can be operated under Linux with the help of NTP package. NTP stands for Network Time Protocol. It is used to synchronize computers with each other via TCP/IP. For operation on Linux, the V.24 output protocol must be changed to XNTP (see 5.3).
4.2.1 NTP installation For easy installation of NTP, you will find the shell script make all.sh on the driver CD under “tools\linux\get ntp”. The script loads the NTP package from the Internet and compiles it. Copy the get ntp folder to your hard drive. Now, run the script. make all.sh with the order ‘-/make all.sh’ Off. After the successful passage of the script, the finished NTP package is on your computer. Close the installation with the command ‘make install’ ab.
4.2.2 NTP configuration NTP reaches through the symbolic link /dev/refclock-0 on the Network Time Server to. If you have the Network Time Server for example, COM1 have been connected, then must /dev/refclock-0 on /dev/ttyS0 (for COM2:) /dev/ttyS1) refer to the reference. If you own a Linux distribution with kernel 2.4 or older, you can link to “ln -s /dev/ttyS0 /deV/refclock-0 create.

Managed from Kernel 2.6 udev the input/output device files. So that the link to refclock-0 from udev automatically created or If it is not preserved, a “rule” must be set for this link. Then move to the folder. rules.d Your udev directory (e.g.) /etc/udev/rules.d) and open the file 50-udev.rules. Insert the following line at the point in the file where serial interfaces are defined: KERNEL==“ttyS0”, NAME=”%k”, SYMLINK=“refclock %n“, GROUP=“uucp”

Then udev or the computer is restarted. The following day must be added to the file ntp.conf to allow NTP to record the time information from Network Time Server picked up:

This means that the time information is transmitted by the device with the aid of driver 12 in group 8 . refclock-0 to be recovered. For testing purposes, you can also select the 127.127.1.0 driver here. This causes NTP to use only the computer internal CMOS clock as time information.
4.2.3 Starting NTP To get an accurate statement about the receiver's reception quality, you must use the program ntpq use. Call them to it. ntpq With the order “ntpq -c clocklist‘ open’.

Will be ntpq Without further options, the localhost is called as

Figure

4.2.4 Setting up NTP daemon How all Unix system services (Daemons) should be ntpd With the help of a so-called "seal". RC script is started. For example, if you use NTP from the RPM of SuSE Linux, find such an rc script in /etc/init.d/xntpd. With this, you can use ‘# /etc/init.d/xntpd start’‘or’, ‘# /etc/init.d/ntpd stop’ The NTPDaemon is started or shut down. An example script can also be found on the accompanying CD-ROM. To automatically start the rc script at system startup, you must ensure that a link is provided in the relevant runlevels. /etc/init.d/xntpd is created. SuSE Linux users can use the Runlevel Editor in ‘yast’ for this purpose.


4.3. V.24 output records The Network Time Server is designed for many time applications. Since different time formats and protocols are required as a basic requirement for many applications, it is possible to vary the protocol output via the serial interface in the web interface (see 5.3).
4.3.1 The Gude Standard Time Protocol The Gude standard time protocol was developed by the company Fa. Gude developed on the basis of CET/CEST especially for PC radio watch systems. Central European Time (CET) is the time zone valid for central Europe and thus, among others, Germany, Austria and Switzerland. Their difference to the world time UTC is +1 hour. The difference between Central European Summer Time (CEST) and Universal Time is +2 hours.
4.3.2 The Gude UTC time protocol Here, the time is output as UTC time instead of CET/CEST. The coding is carried out as in the Gude standard time protocol.
4.3.3 The XNTP time protocol The XNTP time protocol was developed for NTP applications. More detailed information about the structure of the protocol can be found on the Internet, for example at http://www.ntp-zeit.de

5.1 Automatic configuration via DHCP After the search, he will look for Network Time Server a DHCP server on the network and requests a free IP address from it (for deactivation of this function see 5.3). In the settings of the DHCP server, check which IP address is Network Time Server Then, if you are assigned and ask for it. that the same address is used for each restart.
5.2 Configuration with the Software GBL Conf.exe To change the network settings, you need to use the program GBL Conf.exe. The program is free on our website www.lindy.de available. You can also use the program GBL Conf.exe also apply firmware updates and Network Time Server Reset to factory settings.


Launch the Network Time Server in Bootloader mode (see 6.1) and open the program GBL Conf.exe. The program automatically searches for connected devices and displays their network configuration. If the displayed IP address is factory (192.168.0.2), either there is no DHCP server in the network or a free IP address could not be assigned. In the input window, enter a free IP address and the associated network mask and save the changes under Program DevicegSave Config. Turn it on. Network Time Server in and out so that the changes take effect. Now go to the GBL Conf.exe program Search search. The new network configuration is displayed.
5.3 Configuration via web interface Call the web interface of Network Time Servers in an Internet browser on http://“IP” address Network Time Server And log in. You will now see a status overview of your Network Time Servers. The tabs in the upper left corner of your screen give you access to the setting options for your Network Time Servers.

Configuration - Network Time Server LCD Display Select the time format which is displayed in your LCD Network Time Servers is to be used. You have the choice between CET/CEST (MEZ/CESZ) and UTC time format.

V.24output protocol Here you can select the format in which the time signal should be transmitted via the serial interface (see 4.3). Language Here you can set the language in which information should be displayed on the screen. You have the choice between German, English, Dutch and Danish. Time switch clock settings Here you can set different times and time intervals for switching operations of the programmable relay output. They can set on and off processes separately. Confirm your settings by pressing the “Set” button. By activating the time switch clock settings, the setup made takes effect. Configuration - IP Address Devicename Here can be a name with max. 15 signs will be given. With this name, the device logs into the DHCP server.



Umlauts and special characters on the name can cause problems in detecting Network Time Servers on your network. IP address Change the IP address of your Network Time Server. Netmask Change the netmask of your Network Time Server. Gateway Change the standard gateway of your Network Time Server. Use of DHCP Determine here whether you Network Time Server You want to get the TCP/IP settings directly from your DHCP server. When the function is activated, a check is made after each switch-on to see if there is a DHCP server in the network. The IP configuration is then requested. If there is no DHCP server on the network, it is recommended to disable this option.

Changes to the IP configuration and deactivation of DHCP will only take effect after re-energizing Network Time Server. Configuration - IP ACL Reply ICMP-Ping requests If you activate this function, your answer is Network Time Server ICMP (Internet Control Message Protocol) pings from the network plant. Enable IP filters Activate or deactivate the IP filter of the IP Access Contol List. The IP filter provides access control for your Network Time Server in this case. Further information on the IP Access Control List can be found in chapter 3.5.


Please note that when IP access control is activated, DHCP, SNMP and SNTP will only work properly if the corresponding servers and clients are registered in the IP ACL. Configuration – HTTP HTTP Port Here, the port number of the internal HTTP web server can be set as required. Values from 1 to 65534 are possible (standard: 80). The port number is now sent to the address of Network Time Servers with a colon attached, such as: http://192.168.0.2:1720/

Changes to the HTTP port will only take effect after re-energizing Network Time Server. Require HTTP Password If desired, the password canAccess protection be activated. In this case, an admin access password must be assigned. The password may have a maximum of 15 characters. If the admin access password is assigned, you can only log in by entering this password to change settings. If you have forgotten the password, activate it Network Time Server in bootloader mode and set the settings with the help of GBL Conf.exe back to the factory state.

Configuration – SNMP Enable SNmp-get Here you can set whether your Network Time Server via the SNMP protocol.

SNMP public community Here you can enter the SNMP working group. Use the SNMP settings only if your network is designed for this. For more information about the operation of your network time servers with SNMP, see chapter 3.3. Configuration – Syslog Use Here you can set whether the sys-log information is passed on via the network work. Syslog Server IP If you have the point Use syslog have activated, enter the IP address of the server to which your syslog information Network Time Servers to be transferred. Syslog Port Enter the port through which the server receives syslog information from the network.

5.4 Display of the current configuration After a successful start of Network Time Servers A short press on the bootloader button displays the device's actual IP address. In addition, the leading character can be used to identify what kind of IP address it is: * The displayed IP address has been fixedly assigned. DHCP is deactivated.

D The displayed IP address was obtained from a DHCP server.

F DHCP is activated, but no IP address could be obtained. The IP address displayed is a default IP address. 6 Equipment characteristics
6.1 Bootloader mode Around the Network Time Server When you start in bootloader mode, hold the small button between serial port and power supply connection for at least two seconds. Whether the Network Time Server In bootloader mode, you can recognize GBL Conf.exe Program window on the addition „BOOT-LDR“ behind the device name and on the slowly blinking V.24 LED. From Bootloader V. 2.2 a display of the bootloader mode is integrated in the LCD display. In bootloader mode, the program can be used to GBL Conf.exe.exes deactivate the password, perform a firmware update and restore the factory status.
6.2 Firmware Update To perform a firmware update, the program GBL Conf.exe.exes The current firmware is required. Start the one Network Time Server in bootloader mode (see Chapter 6.1).
6.3 Technical data Interfaces: Ethernet, potential-free switching output, 9 pin D-SUB (RS232), BNC antenna connection network connection: 10 MBit 10BaseT Ethernet /100 Mbit 100Base T protocols: TCP/IP, NTP, HTTP, SNMP voltage supply: plug power supply (9 V) Operating temperature: 5°C - 55°C Measurements: 17 x 10.5 x 6.5 cm (L x B x H) Weight: 0.73 kg

Active ferrite bar antenna (BNC) Working temperature: -15°C-60°C Dimensions: 21.5 cm long, 2 cm diameter cable: 5 m coaxial cable (can be extended up to 150 m) 7 Support In the software for Windows, a help file can be called will become. There you will find further information about individual functions and the operation of Network Time Server and a detailed FAQ list. On our websites under www.lindy.de the latest drivers and software for our products are available to you free of charge. For further questions about installation or operation of the Network Time Server Please contact our support team