2.1. TheVirtual USB-IP Driver Software This contains a Virtual Bus Enumerator driver & Virtual Bus driver. These drivers will help in vitalizing the USB devices, for each attached device on the USB-Server. Virtual Bus driver takes the USB traffic from the USB Client drivers and passes it to the USB-Server, which is sitting remotely on the network. As soon as the utility is installed this application icon will be placed in the system tray as shown in the figure below.

Double click the icon on the system tray to view the Full screen mode of the PC client application as shown below.

The application has four panels, which are docked in the application.
1) Main window: This displays all the Device server and the USB Devices connected on them 2) Function Panel: This panel enables to switch between the Device Mapping and Server Manager Application. 3) Device Details Panel: This displays the more verbose information of the server and the device selected on the main window. 4) Log panel: Any event on the USB server creates a log in the Log panel. This helps in continuous monitoring of USB device servers on the network. The Admin Utility has two main functionalities built in
a) Device Mapping b) Server Manager

Device Mapping enables virtualization of all USB Devices connected to the USB 2.0 DEVICE SERVER unit in your LAN on your local PC.
Click on the Green Arrow Button in the Admin utility to start the device mapping, which will automatically start the ‘Found New Hardware’ wizard to install the Virtual USB driver.
Continue the Add New Hardware wizard to install the Virtual USB driver for the USB 2.0 DEVICE SERVER Admin utility.
Select “Search for a suitable driver for my device (recommended)” and click on ‘Next’, the Operating System automatically will search for the driver until the Virtual USB over IP driver is installed.
Please Click on “Continue anyway” if a Windows dialog pops up about the Digital Signature as shown below.

Power on the USB 2.0 DEVICE SERVER board and connect an Ethernet cable from the USB 2.0 Device Server Ethernet port to your Local Area Network.
The USBIP Admin utility is capable enough to identify the USB 2.0 DEVICE SERVER USB servers by it’s IP address on the network. As soon as the USB 2.0 DEVICE SERVER box is detected with a specific IP address the Windows automatically invokes a Found New Hardware Wizard to install the drivers for the USB server box.

Continue the Installation to see the USB 2.0 DEVICE SERVER board and the USB devices connected in the Admin utility as shown below.
In the Device mapping window, all the USB devices are shown as a tree under the USB Server.
Right click on any device and click on “Connect” to virtualize that USB device onto your PC as shown below .


2.3. Server Manager The Server manager enables the Administrator to configure the USB 2.0 Device Server via the network.

The Server Manger also has an option to search for the device on the Network:
Right Click on the Server Manager Main window and Click on Search server as shown below .


The dialog ‘Searching for Servers’ dialog will appear and list all the USB 2.0 Device Server devices on the Network as shown below

The USB Device Server search is password protected and should be unlocked in order to configure the selected device.

On selecting ‘Unlock’ the password dialog pops up as shown below. Key in the password in the ‘Password’ dialog. The default password for the USB IP Server is “combo”

If the Authentication has been successful an ‘Unlock OK’ dialog appears. The Device server can now be configured for various settings as given below.

The Server Manager has an option to change Server Configuration settings through USBIP Admin Utility. To open server configuration window right click on the USB 2.0 DEVICE SERVER server displayed on the Server Manager Main window and select “Server Configuration” option as shown below.

The Server Configuration window will appear as shown below.


Basic Settings:
The Basic Settings page allows you to specify a server name. Check the modify box and enter server name as shown below.

IP Settings:
The IP Settings page allows you to modify MCS 8140-D box IP Address as shown below.

The Default IP Address is 192.168.3.22
To modify the IP Address of the USB 2.0 DEVICE SERVER box, check the ‘Modify’ box and Select IP Configuration (Select IP configuration Static/DHCP from IP Configuration drop-down box) as shown below.


After selecting IP Configuration key in the IP Address of the USB 2.0 DEVICE SERVER box in the IP Address field followed by proper Subnet Mask & Gate Way as shown below.

After entering IP address, Subnet Mask & Gate Way then click on “save” button. Then USBIP Admin shows a progress bar, after the process is finished, the following message box will be displayed.

Continue the Found New Hardware Wizard to install the Virtual USB-over-IP bus driver.
Now USB 2.0 DEVICE SERVER box appears with changed IP Address under USBIP Admin utility.
Password:
The Password Settings page allows you to change or Enable/Disable password of the USB 2.0 DEVICE SERVER box. The Password settings page will be as shown below.

Check the Modify box to Enable or Disable password option to USB 2.0 DEVICE SERVER box.

2.3.2. Firmware Upgrade The USB 2.0 Device Server Firmware can be upgraded remotely using the Firmware upgrade option. Select the server on the Server manager. Right Click on the server and Select Upgrade Firmware option to upgrade the firmware.

Select the file to be upgraded by click on the Browse option in the “Select File” dialog as shown below.

An upgrade.tar.bz2 file is required to upgrade the firmware. The upgrade .tar file can be downloaded from our website www.lindy.com
Click on “Transfer” to upgrade the firmware. A firmware upgrade status is displayed which automatically relinquishes once the transfer is completed.

As soon as the transfer is completed, the USB 2.0 DEVICE SERVER USB server box automatically restarts to apply the upgraded firmware settings.

2.3.3. Restore factory defaults Right click on the USB 2.0 DEVICE SERVER in the Server Manager Window and select the Restore Factory Defaults function to obtain Default settings as shown below.

Then USBIP Admin Utility pops up a window asking for to continue or not. If we select Ok button it will get default settings.

2.4. Printer Auto-Connect: USB Admin Utility enables Printers be shared between multiple clients making it a bidirectional Print Server. In order to share the printer between multiple clients the user may need to connect the printer at least once to install the driver for the Printer. Once the printer is enumerated disconnect the Printer form the Device Mapping Window, Select the
Printer Auto Reconnect button
on the Menu bar to open the Printer Auto-Connect Window.


Select the Printer which was connected and Click on “Save” and close the Window. Once the Printer is configured for Auto-Connect mode, It remains free as long as the Printer is connected and becomes “Busy” only when a user prints to the printer connected. Multiple User print jobs will be executed on a time sharing basis.


If the authorization has been successful, the home page of the USB 2.0 DEVICE SERVER NAS application will be visible as shown below.

3.1. Network Settings The “Network” tab allows you to configure both wired as well as wireless interfaces. For the wired side we can configure the Static IP manually or set the box to automatically obtain an IP address by setting to the Dynamic (DHCP) mode. (Make sure that the DHCP server should be in ON).

If the user selects the Network Interface type as “Wireless LAN” the browser shows the Wireless configuration web page as shown below.


Select the Server IP Type, and select Static in order to change the IP address, Subnet mask and Default Gateway of the Box. If the choice is made as “Dynamic (DHCP)”, the box will automatically try to get an IP Address from the wireless router available. In the Wireless configuration the application can also list the Wifi access points available in the network in the Wi-Fi Router Name. If the choice has to be made to connect to a specific Wireless Router or access point choose “Select” radio button and select the Wireless router in the dropdown menu.
3.2. Secure NAS Settings The web-server has separate webpage to configure Secure NAS. Click on the Secure-NAS tab to view the secure NAS settings in the Combo NAS USB IP solution.


3.2.1. Shares setting The “Shares” tab is for creating/editing/deleting a share. A share is the partition of the disk that you want others in the network to access. When a disk is connected to the NAS box the partitions and their statistics will be shown in this page.

Specify the name in the “Enter a New Share Name” field to create a new share. If you have already created a share then they will be shown in the “Select to Edit Share” and “Select to Delete Share” lists that will allow you to edit/delete the shares. When you click “Create Share” the parameters required for creating a new share are displayed.

Once a share is created by some the name (Ex: “flash_drive”), then you will be prompted to enter the parameters for the share.

3.2.2. User Settings In the “Users” tab you can add/delete/enable/disable a user. You can also change the password for a specified user. The list of registered users will be displayed at the bottom. Enabling/Disabling a user means if a user has been created and you want the user not to access any share then you can disable that user. Means he will not be entirely deleted but only restricted to access any share.

A username “moschip" is by default present, which is shown in the Registered User(s) table.

3.2.3. IPSec Security Settings In the “Security” tab you can configure a VPN with a client for secure access to the box. The box uses IPSec for establishing a VPN.

By default the security will be disabled. Then we have the encryption and authentication settings. The USB 2.0 DEVICE SERVER NAS will support 3DES, AES128, AES192 and AES256 encryption techniques and MD5, SHA1 authentication techniques.

The “Key Management” allows setting the type of key management whether Auto IKE (Internet Key Exchange) or “Manual”. In the below figure the “Auto (IKE)” is selected. Under this you have an option for enable/disable PFS (Perfect Forward Secrecy) which is useful for key exchange. The “Pre-shared Key” field is to specify what key to use and the “Key Life Time” field is the amount to specify the key lifetime in seconds.

The below figure is the “Manual” configuration of Key Management. Here we have to specify the “Encryption Key” as well as the “Authentication Key”. Apart from these we have a SPI (Security Parameter Index) field with which the SA’s (Security Associations) will be identified.


The connection status (Disconnected/Connected) will be displayed at the bottom in red.

Please check the Appendix section to know on how to configure IPSec on a Windows XP machine.
3.2.4. The Status page In the “Status” tab you can view the NAS server status, active connections, active shares and opened files in a very informative way.

The “Auto Refresh” button when clicked will keep on refreshing the page based upon the given refresh time interval. The “Active Connections” will display the IP addresses and the PC names that have connected to the NAS box. In the “Kill” column you can close a connection by clicking “X” mark. But the client can re- establish the connection. The “Active Shares” page will display which share is accessed by which client. The “Open Files” will display which files are currently opened by which client. The file permissions are also displayed here.

3.3. Virtual USB-IP Settings The web-server has separate webpage to configure Virtual USB server settings. Click on the Virtual USB tab to view the USB server settings in the Combo NAS USB IP solution.




3.3.2. The Upgrade Page The Upgrade page allows you to upgrade the firmware.

Select the file to be upgraded by click on the Browse option on the Upgrade page as shown below.


A file named upgrade.tar.bz2 file is required to upgrade the firmware. If one is availableThe upgrade .tar file can be downloaded from the LINDY website, www.lindy.com

Click on “upgrade” to upgrade the firmware


A file successfully uploaded message is displayed and the webpage also indicates that the USB 2.0 DEVICE SERVER box is restarting to apply the upgraded firmware settings.

Shortcut: Goto Programs > Run. Type the IP address of the unit in the Run Dialog as show below.


OR Type the box name in the Run dialog as follows: \\mcs8140

FCC Warning This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. CE Statement, EMC Compatibilty This device complies with EN Standards EN55022 and EN55024 according to the relevant EC EMC Directive. It must be used with shielded cables only to maintain EMC compatibility. Dieses Produkt entspricht den einschlägigen EMV Richtlinien der EU und darf nur zusammen mit abgeschirmten Kabeln verwendet werden. LINDY Herstellergarantie
LINDY gewährt für dieses Produkt über die gesetzliche Regelung hinaus eine zweijährige Herstellergarantie ab Kaufdatum. Die detaillierten Bedingungen dieser Garantie finden Sie auf der LINDY Website aufgelistet bei den AGBs.
WEEE (Waste of Electrical and Electronic Equipment), Recycling of Electronic Products In 2006 the European Union introduced regulations (WEEE) for the collection and recycling of all waste electrical and electronic equipment. The wheelie bin symbol shown indicates that this product must not be disposed of with household waste. Instead the product must be recycled in a manner that is environmentally friendly. For more information on how to dispose of this product, please contact your local recycling centre or your household waste disposal service. Each individual EU member state has implemented the WEEE regulations into national law in slightly different ways. Please follow your national law when you want to dispose of any electrical or electronic products. More details can be obtained from your national WEEE recycling agency.
Germany / Deutschland Die Europäische Union hat mit der WEEE Direktive umfassende Regelungen für die Verschrottung und das Recycling von Elektro- und Elektronikprodukten geschaffen. Diese wurden von der Bundesregierung im Elektro- und Elektronikgerätegesetz – ElektroG in deutsches Recht umgesetzt. Dieses Gesetz verbietet vom 24.März 2006 an das Entsorgen von Elektro- und Elektronikgeräten über die Hausmülltonne! Diese Geräte müssen den lokalen Sammelsystemen bzw. örtlichen Sammelstellen zugeführt werden! Dort werden sie kostenlos entgegen genommen. Die Kosten für den weiteren Recyclingprozess übernimmt die Gesamtheit der Gerätehersteller.
1st Edition, Oct 2008
LINDY No 42829
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.