Instruction/ maintenance manual of the product FDDI Cabletron Systems
Go to page of 32
Title Page 7F06-02 FDDI Smar tSwitch ™ Interf ace Module User’ s Guide 903 9031672-02.
.
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide i NOTICE Cabletron Systems reserves the right to make changes in specifications and other information contained in this document without prior notice. The reader should in all cases consult Cabletron Systems to determine whether any such changes ha ve been made.
Notice ii 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide DOC NOTICE This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications.
Notice 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide iii CABLETRON SOFTWARE PROGRAM LICENSE 1. LICENSE . You have the right to use only the one (1) copy of the Program provided in this package subject to the terms and conditions of this License Agreement.
Notice iv 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide DECLARATION OF CONFORMITY Application of Council Directiv e(s): 89/336/EEC 73/23/EEC Manufacturer’ s Name: Cabletron Systems, Inc. Manufacturer’ s Address: 35 Industrial Way PO Box 5005 Rochester, NH 03867 European Representativ e Name: Mr.
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide v CONTENTS CHAPTER 1 INTRODUCTION 1.1 Using This Manual ....................................................................... 1-1 1.2 The 7F06-02 Module ......................................
Contents vi 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide CHAPTER 5 T ECHNICAL SPECIFICATIONS 5.1 Standards ..................................................................................... 5-1 5.2 EMI .................................
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 1-1 CHAPTER 1 INTR ODUCTION W elcome to Cabletron Systems 7F06-02 FDDI SmartSwitch Interface Module User Guide .
Chapter 1: Introduction 1-2 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 1.2.1 Cable T ype and FPIMs The 7F06-02 module has two front panel connectors that interface to the 7X00 SmartSwitch Module through the chassis backplane. The front panel connections are standard Cabletron FPIMs.
Chapter 1: Introduction 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 1-3 1.2.2 7C03 MMA C Smar tSwitch, the 7C04 W orkgr oup SmartSwitch and the 7C04-R W orkgroup SmartSwitch The 7F06-02 Module is designed to be installed in the 7C03 MMA C SmartSwitch, the 7C04 W orkgroup SmartSwitch or the 7C04-R W orkgroup SmartSwitch.
Chapter 1: Introduction 1-4 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 1.3.3 Connectivity The 7F06-02 Module has one backplane connection and two sets of A/B front panel FPIM connections. The backplane connection pro vides po wer to the 7F06-02 Module and a channel for communication with the 7X00 SmartSwitch Control Module.
Chapter 1: Introduction 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 1-5 1.5 GETTING HELP If you need additional support related to this de vice, or if you hav e an y questions, comments,.
Chapter 1: Introduction 1-6 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide.
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 2-1 CHAPTER 2 NETW ORK REQUIREMENTS Before installing Cabletron Systems 7F06-02 Module, re view the network requirements outlined in this chapter . All requirements included in this chapter should be met to ensure satisfactory performance of the 7F06-02 Module.
Chapter 2: Network Requirements 2-2 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide The link distance is up to 2 kilometers on the multimode fiber optic cable as specified by ANSI MMF-PMD. 2.1.2 FPIM-02 and FPIM-04 The FPIM-02 has an RJ-45 connector supporting an Unshielded T wisted Pair (UTP) connection.
Chapter 2: Network Requirements 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 2-3 2.1.3 FPIM-05 and FPIM-07 The FPIM-05 and FPIM-07 provide a single-mode fiber connection. The FPIM-05 uses a MIC style connector and the FPIM-07 uses an SC type connector .
Chapter 2: Network Requirements 2-4 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide.
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 3-1 CHAPTER 3 INSTALLATION/REMO V AL This chapter contains instructions for unpacking and installing the 7F06-2 Module in the: • 7C03 MMA C .
Chapter 3: Installation/Remov al 3-2 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 3.2 INSTALLING FPIMS The 7F06-02 module is shipped without FPIMs. T o install an FPIM, follo w the procedure belo w: 1. Remove the module if it is installed in the 7C03 MMAC SmartSwitch chassis by reversing the procedure in Section 3.
Chapter 3: Installation/Remov al 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 3-3 3.3 INSTALLING/REMOVING THE 7F06-02 MODULE The follo wing procedure details the installation and remov al procedure for the 7F06-02 module.
Chapter 3: Installation/Remo v al 3-4 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 3.3.2 Removing fr om the 7C03 Smar tSwitch The 7F06-02 Module inserted in the 7C03 MMA C SmartSwitch can be remov ed upon proper remo v al of po wer . Follow the steps belo w and refer to Figure 3-3 to remov e the module.
Chapter 3: Installation/Remo v al 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 3-5 3.3.3 Installing in the 7C04 or 7C04-R W orkgroup SmartSwitch The 7F06-02 Module is installed in the 7C04 or 7C04-R W orkgroup SmartSwitch using the follo wing steps and referring to Figures 3-4 and 3-5.
Chapter 3: Installation/Remo v al 3-6 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide Figure 3-4 Installing the 7F06-02 Module in the 7C04 W orkgroup SmartSwitch Figure 3-5 Installing the 7F.
Chapter 3: Installation/Remo v al 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 3-7 3.3.4 Removing the 7F06-02 fr om the 7C04 or 7C04-R W orkgr oup SmartSwitch The 7F06-02 Module, inserted in the 7C04 or the 7C04-R W orkgroup SmartSwitch, can be removed whene v er necessary .
Chapter 3: Installation/Remo v al 3-8 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide Figure 3-7 Removing the 7F06-02 Module fr om the 7C04-R W orkgroup SmartSwitch FANS SN 4 3 2 1 Ejector T.
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 4-1 CHAPTER 4 T R OUBLESHOOTING 4.1 DIAGNOSTIC AND MONITORING SYSTEM The 7F06-02 Module uses LANVIEW , Cabletron Systems’ b uilt-in visual diagnostic and status monitoring system.
Chapter 4: T roubleshooting 4-2 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 4.2 P OR T RECEIVE LEDS T able 4-1 indicates the state of the receive port. 4.3 P OR T T RANSMIT LEDS T able 4-2 indicates the state of the transmit port. 4.4 A/B LINK LEDS T able 4-3 indicates the state of the A/B Link LEDs.
Chapter 4: T roubleshooting 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 4-3 Green Off Green Green THR U B, MA C on Secondary , Primary Bypasses Board Green Y ellow Green Green THR U B, M.
Chapter 4: T roubleshooting 4-4 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide.
7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 5-1 CHAPTER 5 T EC HNICAL SPECIFICATIONS This chapter includes the technical specifications for 7F06-02 module. Cabletron Systems reserves the right to change these specifications at an y time without notice.
Chapter 5: T echnical Specifications 5-2 7F06-02 FDDI SmartSwitch Interface Module User’ s Guide 5.5 SAFETY It is the responsibility of the person who sells the system to which the module will be a part to ensure that the total system meets allo wed limits of conducted and radiated emissions.
An important point after buying a device Cabletron Systems FDDI (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Cabletron Systems FDDI yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Cabletron Systems FDDI - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Cabletron Systems FDDI you will learn all the available features of the product, as well as information on its operation. The information that you get Cabletron Systems FDDI will certainly help you make a decision on the purchase.
If you already are a holder of Cabletron Systems FDDI, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Cabletron Systems FDDI.
However, one of the most important roles played by the user manual is to help in solving problems with Cabletron Systems FDDI. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Cabletron Systems FDDI along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center