MJB - Gateway

To learn more about LINAK please visit: W W W. L I N A K . C O M





We are delighted that you have chosen a product from LINAK®.
LINAK systems are high-tech products based on many years of experience in the manufacture and development of actuators, electric control boxes, controls and chargers.
This User Manual will tell you how to install, use and maintain your LINAK equipment.
We are sure that your LINAK system will give you many years of problem-free operation. Before our products leave the factory they undergo full function and quality testing. Should you nevertheless experience problems with your systems, you are always welcome to contact your local dealer.
LINAK subsidiaries and some distributors situated all over the world have authorised service centres, which are always ready to help you.
LINAK provides a warranty on all its products. This warranty, however, is subject to correct use in accordance with the specifi cations, maintenance being done correctly and any repairs being carried out at a service centre, which is authorised to repair LINAK products.
Changes in installation and use of LINAK systems can affect their operation and durability. The products are not to be opened by unauthorised personnel. The User Manual has been written on the basis of our present technical knowledge. We are constantly working on updating the information and we therefore reserve the right to carry out technical modifi cations.

Failure to comply with these instructions may result in accidents involving serious personal injury.
Failing to follow these instructions can result in the product being damaged or destroyed.
Safe use of the system is possible only when the operating instructions are read completely and the instructions contained are strictly observed. Failure to comply with instructions marked with the”NOTE” symbol may result in serious damage to the system or one of its components. Persons who do not have the necessary experience or knowledge of the product/ products must not use the product/ products. Besides, persons with reduced physical or mental abilities must not use the product/products, unless they are under surveillance or they have been thoroughly instructed in the use of the apparatus by a person who is responsible for the safety of these persons. Moreover, children must be under surveillance to ensure that they do not play with the product.
It is important for everyone who is to connect, install, or use the systems to have the necessary information and access to this User Manual.
If there is visible damage to the product it must not be installed.
The appliance is not intended for use by young children or infi rm persons without supervision.
Young children should be supervised to ensure that they do not play with the appliance.

Residual risk Some of the products contains software based components. LINAK has made various possible efforts to assure that the software is free of errors and that the software has been developed according to the rules of IEC 60601-1-4 (software in Medical products). That involves Risk Analysis which shows a small residual risk for unwanted/unintended movement of actuators under specifi c conditions. According to the above rules it must be informed and if necessary considered in the Risk analysis of the fi nal application - More details to residual risk can be provided by LINAK if necessary.
The LINAK products cannot tolerate the infl uence of strong solvents, basic or alkaline liquids.

Information on the MJB The MJB Modular Junction Box is designed for use together with OpenBus™ control boxes. The MJB makes it possible to connect multiple handsets, attendant controls or it makes it possible to use the MJB as a control unit for 3rd party products as Out of Bed detection, USB charger, Under Bed Light etc.
LINAK A/S delivers only the OpenBus system and is not responsible for any products other than LINAK products (i.e. products from 3rd party suppliers) or the compliance of such products with the LINAK OpenBusTM system.

Repairs In order to avoid the risk of malfunction, all repairs must only be carried out by authorised LINAK workshops or repairers, as special tools must be used and special gaskets must be fi tted. Products under warranty must also be returned to authorised LINAK workshops.
Disposal of LINAK’s products LINAK’s products may be disposed of, possibly by dividing them into different waste groups for recycling or combustion.
We recommend that our product is disassembled as much as possible at the disposal and that you try to recycle it. As an example of main groups within sorting of waste we can mention the following:
Metal, plastic, cable scrap, combustible material and collection for recoverable resources.
Some of these main groups can be sub-divided into groups e.g. metal can be divided into iron, stainless steel and aluminium and alloy steel. Plastic can e.g. be divided into ABS, PA, PE and PP.
By now all our casted plastic units are provided with an interior code for plastic types and fi bre contents, if any.

Warranty and service life The LINAK warranty covers manufacturing defects in the products, starting from the date of manufacture. There is 18 months’ warranty for MEDLINE and CARELINE products. The warranty is limited to the value of the LINAK product.
LINAK’s guarantee is only valid so far as the products have been used and maintained correctly and has not been tampered with. Furthermore, the products must not be exposed to violent treatment. In the event of this, the warranty will be ineffective / invalid. LINAK’s warranty is only valid if the system is unopened and has been used correctly.
All LINAK products are designed to have an optimum service life as a matter of course, but the expected service life in a specifi c application is very dependent on how the products are used.

The MJB is a simple gateway interface, which can connect the bed to the infrastructure of the hospital or nursing homes. The Gateway can be used in combination with an Out of Bed Sensor, which makes it possible to indicate if the patient leaves the bed. The Gateway can also be used as a service/nurse call system. Please note it is only to be used as a guided system, not for emergency issues.

Relay 1:
- Pin 1 - Pin 2 - Pin 3 Relay 2:
NO
- Pin 4 - Pin 5 - Pin 6
NO
Port 1 OpenBus connetion
Standard functionality: The MJB - Gateway consist of two relays, which are connected through Port 5 on the MJB. This can be made with the special cable 0964140 (Modular plug - Open end) There are as standard 2 confi gurations, 504-01 and 504-02, see description on the next pages.
Relay1: NC (normally closed) = Pin 2 + Pin 1 / NO (normally open) = Pin 2 + Pin 3 Relay2: NC (normally closed) = Pin 5 + Pin 4 / NO (normally open) = Pin 5 + Pin 6
Relay 1 is NO when connected to the mains and NC when no mains, this means the relay is “active”, when connected to the mains (closed loop). The Closed Loop principal is to ensure that an alarm is sent if power is missing on the bed. When the mains is disconnected (power is missing), the relay will go from NO to NC, which will automatically result in an alarm (status indicator) on the OpenBus™. Relay 1 can be activated via the patient control (Key1 / Key4) or the attendant control (Key2 / Key3). When a key is activated, the relay will switch state from NO to NC for 2 seconds. After 2 seconds the relay will automatically change state from NC to NO. The status of the relay is indicated on the OpenBus™ and can be used for switching on an LED.
Relay 2 is as default NC, with or without mains, (Open Loop) Relay 2 can be activated via the patient control (Key 1) or the attendant control (Key 2 / Key 3). When the relay is activated, it will switch from NC to NO for 2 seconds. After 2 seconds the relay will automatically change state from NO to NC. The status of the relay is indicated on the OpenBus™ and can be used for switching on an LED.
Port 5

By using the variant 504-02 relay 2 will be controlled by the MJB variant 505/506 with switch input. Alarm 1 = Switch input S2 (OoBD alarm) / Alarm 2 = Switch input S1 When using this combination, is it important to have the MJB 505/506 connected to the system all the time. If it is not connected, the Gateway MJB will see it as an alarm and the relay will be activated. The Gateway MJB is “scanning” the OpenBus™ system every minute for an alarm.
Options (special article): • Customised SW: It is possible to defi ne the OpenBus™ signals to be used for activating the relays and / or change the alarm indicator, so that it fi ts to the customers system. Please contact your Sales Engineer at LINAK A/S for further information.

\* When the mains is unplugged or CB is in power down will the relay shift to NC state and generate alarm. \** Alarm generated by nurse call or bed alarms

3rd. party site
In this state no Alarm
3rd. party site

In this state no Alarm

CB Power mode Gateway
On mains Function ok



Please note, the slit is placed on the opposite side of the modular plug. This is to ensure that the cable is only being used for the Gateway MJB.

All LINAK products can be cleaned as follow according to their IP protection, which is stated on the product label. The IP code specifi es the degrees of protection provided by the enclosures. Only the protection against ingress of water (second characteristic numeral) is specifi ed, ingress of solid foreign objects (fi rst characteristic numeral) is not specifi ed and therefore replaced by the letter X in the code.
IPX0 Clean with a damp cloth
IPX1 Clean with a damp cloth
IPX2 Clean with a damp cloth
IPX3 Clean with a damp cloth
IPX4 Clean with a damp cloth
IPX5 Wash with a brush and water, but not water under pressure
IPX6 X Wash with a brush and water. The water can be under pressure, but the system must not be hosed down directly with a high-pressure cleaner. Max. 20oC
IPX6 Washable Clean by the use of water tunnels
The materials are resistant to the majority of cleaners and disinfectants used in the hospital and nursing home sector.
Cleaning with a steam cleaner, for example, is not permitted, as it will not be possible to maintain a minimum distance of 300 mm from the electrical parts.

Precaution! When cleaned, water must never be sprayed upwards from underneath the bed, because it may enter the cable outlet.
Operating:
Temperature Relative humidity Atmospheric pressure
5°C to 40°C 20% to 90% @ 30°C – not condensing 700 to 1060 hPa
Storage:
Temperature Relative humidity Atmospheric pressure
-10°C to +50°C 20% to 90% @ 30°C – not condensing 700 to 1060 hPa
Valid where nothing otherwise is stated under the specifi c products in a later section.

To be used with LINAK products. Can be connected to all ports in the MJB,
both ports with narrow and wide slit.

To be used with 3rd party products. Can only be connected to ports in the MJB with
to interfere with the OpenBusTM connections.

The following symbols are used on the label on the LINAK products.
Type B equipment, as per EN 60601-1
Protection against contact/foreign matter (first character) and water (second character) as per EN60529

UL fi le number
UL fi le number
UL fi le number
Recognised - Component Mark
Product with a thermofuse
Canadian Recognised - Component Mark
For indoor use (House).
Recognised Component Mark for Canada and the United States
Safety isolating transformer.
Tüv.Produkt Service
Equipment Kl.2 (Double square)
Patient part of type B (Mand)
Patient part of type BF
Equipment class1.
C-ETL
LGA
C-TICK
C-UL US Listing Mark

MJB - Modular Junction Box
MJB







LINAK APPLICATION POLICY The purpose of the application policy is to defi ne areas of responsibilities in relation to applying a LINAK product defi ned as hardware, software, technical advice, etc. related to an existing or new customer application.
LINAK products as defi ned above are applicable for a wide range of applications within the Care and Health, Comfort furniture, Desk and Industry areas. Yet, LINAK cannot know all the conditions under which LINAK products will be installed, used, and operated, as each individual application is unique.
The suitability and functionality of the LINAK product and its performance under varying conditions (application, vibration, load, humidity, temperature, frequency, etc.) can only be verifi ed by testing, and shall ultimately be the responsibility of the LINAK customer using any LINAK product.
It is also the responsibility of the LINAK customer to make and supply a comprehensive user manual of the application.
LINAK shall be responsible solely that the LINAK products comply with the specifi cations set out by LINAK and it shall be the responsibility of the LINAK customer to ensure that the specifi c LINAK product can be used for the application in question.





FACTORIES CHINA LINAK (Shenzhen) Actuator Systems, Ltd. Phone: +86 755 8610 6656 . Fax: +86 755 8610 6990 E-mail: [email protected] . www.linak.cn
NETHERLANDS LINAK Actuator-Systems B.V. Phone: +31 76 5 42 44 40 . Fax: +31 76 5 42 61 10 E-mail: [email protected] . www.linak.nl
DENMARK LINAK A/S . Group Headquarters Guderup Phone: +45 73 15 15 15 . Fax: +45 74 45 80 48 Fax (Sales): +45 73 15 16 13 E-mail: info@linak.com. www.linak.com
NEW ZEALAND LINAK New Zealand Ltd. Phone: +64 9580 2071 . Fax: +64 9580 2072 E-mail: nzsales@linak.com.au . www.linak.co.nz
MEXICO ILSA S.A. de C.V. Phone: +[52] (55) 5388-3960 . Fax: +[52] (55) 5388-3966 E-mail: linak@ilsamexico.com. www.ilsamexico.com
NORWAY LINAK Norge AS Phone: +47 32 82 90 90 . Fax: +47 32 82 90 98 E-mail: [email protected] . www.linak.no
PERU PERCY MARTIN DEL AGUILA UBILLUS Phone: +51 99- 883-9879
POLAND LINAK Polska Phone: +48 (22) 500 28 74 . Fax: +48 (22) 500 28 75 E-mail: [email protected] . www.linak.pl
USA LINAK U.S. Inc. North and South American Headquarters Phone: +1 502 253 5595 . Fax: +1 502 253 5596 E-mail: info@linak-us.com. www.linak-us.com
SINGAPORE SERVO DYNAMICS PTE. Ltd. Phone: +65 6844 0288 . Fax: +65 6844 0070 E-mail: servodynamics@servo.com.sg . www.servo.com.sg
SPAIN LINAK Actuadores, S.L.u Phone: +34 93 588 27 77 . Fax: +34 93 588 27 85 E-mail: [email protected] . www.linak.es
SUBSIDIARIES AUSTRALIA LINAK Australia Pty. Ltd Phone: +61 3 8796 9777 . Fax: +61 3 8796 9778 E-mail: sales@linak.com.au . www.linak.com.au
SOUTH AFRICA Industrial Specialised Applications CC Phone: +27 11 312 2292 or +27 11 2077600 Fax: +27 11 315 6999 E-mail: gartht@isagroup.co.za . www.isaza.co.za
SWEDEN LINAK Scandinavia AB Phone: +46 8 732 20 00 . Fax: +46 8 732 20 50 E-mail: [email protected] . www.linak.se
AUSTRIA LINAK GmbH - Austria Phone: +43 (0) 2266 61 9 62 . Fax: +43 (0) 2266 63 2 99 E-mail: [email protected] . www.linak.at
SWITZERLAND LINAK AG Phone: +41 43 388 31 88 . Fax: +41 43 388 31 87 E-mail: [email protected] . www.linak.ch
BELGIUM & LUXEMBOURG LINAK Actuator-Systems NV/SA Phone: +32 (0)9 230 01 09 . Fax: +32 (0)9 230 88 80 E-mail: [email protected] . www.linak.be
TAIWAN LINAK A/S Taiwan Representative Office Phone: +886 2 250 80296 . Fax: +886 2 2508 3604 E-mail: info@linak.com.tw . www.linak.com.tw
UNITED ARAB EMIRATES Mechatronics Phone.: +971 4 267 4311 . Fax: +971 4 267 4312 E-mail: mechtron@emirates.net.ae www.mechatronics.ae
BRAZIL LINAK DO BRASIL COMÉRCIO DE ATUADORES LTDA. Phone: +55 (11) 2832-7070 . Fax: +55 (11) 2832-7060 E-mail: info@linak.com.br . www.linak.com.br
TURKEY LINAK A/S Turkey Representative Office Phone: +90 312 4726338-59 . Fax: +90 312 4726635 E-mail: vozen@linak.com.tr . www.linak.com.tr
For contact details on other countries please visit www.linak.com or contact:
UNITED KINGDOM LINAK UK Limited Phone: +44(0)121 544 2211 . Fax: +44(0)121 544 2552 E-mail: sales@linak.co.uk . www.linak.co.uk
CZECH REPUBLIC LINAK C&S S.R.O. Phone: +420581741814 . Fax: +420581702452 E-mail: [email protected] . www.linak.cz
DISTRIBUTORS ARGENTINA NOVOTEC ARGENTINA SRL Phone: +[54] (11) 4303-8900/89 . Fax: +[54] (11) 4032-0184 E-mail: info@novotecargentina.com www.novotecargentina.com
Copyright © LINAK 2010.10 MA-M9-02-348 LINAK A/S reserve the right to make technical alterations
DENMARK LINAK DANMARK A/S Phone: +45 86 80 36 11 . Fax: +45 86 82 90 51 E-mail: [email protected] . www.linak.dk
INDONESIA PT. HIMALAYA EVEREST JAYA Phone: +6 221 544 8956/65 . Fax: +6 221 619 4658/1925 E-mail: hejplastic-div@centrin.net.id . www.hej.co.id
INDIA LINAK A/S Asian Representative Office Phone: +91 120 4797013 E-mail: [email protected] . www.linak.in
Terms of use The user is responsible for determining the suitability of LINAK products for specifi c application. LINAK takes great care in providing accurate and up-to-date information on its products. However, due to continuous development in order to improve its products, LINAK products are subject to frequent modifi cations and changes without prior notice. Therefore, LINAK cannot guarantee the correct and actual status of said information on its products. While LINAK uses its best efforts to fulfi l orders, LINAK cannot, for the same reasons as mentioned above, guarantee the availability of any particular product. Therefore, LINAK reserves the right to discontinue the sale of any product displayed on its website or listed in its catalogues or other written material drawn up by LINAK. All sales are subject to the Standard Terms of Sale and Delivery for LINAK. For a copy hereof, please contact LINAK.
ITALY LINAK ITALIA S.r.l. Phone: +39 02 48 46 33 66 . Fax: +39 02 48 46 82 52 E-mail: [email protected] . www.linak.it
MALAYSIA LINAK A/S Asian Representative Office Phone: +60 4 210 6500 . Fax: +60 4 226 8901 E-mail: info@linak-asia.com. www.linak-asia.com
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.