Linak Linear Actuator (LA36)
Table of Contents 49 sections LA36 ACTUATOR · Preface · LINAK A/S · Safety instructions · … ShowHide
LA36 ACTUATORp.1Prefacep.4LINAK A/Sp.4Safety instructionsp.5Important informationp.6Information about the actuators is described under the following two headings:p.6Misc. on the TECHLINE TM actuator systemp.8Specificationsp.9Motor: Permanent magnet motor 12, 24, or 36Vp.9Motor protection: Automatic protection resets thermal overloadp.9Hand crank: As a standard feature the actuator can be operated manuallyp.9End play: 2 mm maximump.9Mounting guidelinesp.10RIGHT WRONG WRONGp.10Warning! LINAK’s actuators are not constructed for use within the following fields:p.10Application hintsp.11Manual hand crankp.116 mm Allen keyp.11Electrical installationp.12Motor connectionp.12Connections diagram: For 36xxxxx0H/Pxxxxxx and 36xxxxx1H/Pxxxxxxp.12Connections diagram: For 36xxxxx2Pxxxxxx and 36xxxxx20xxxxxx:p.13Signal cable Connections diagram: For 36xxxxx2Hxxxxxxp.13Connections diagram: For 36xxxxx3xxxxBxx + 36xxxxx40xxxBxx:p.14Signal cablep.14Connection of the LA36 with the CS16p.15Troubleshootingp.15Symptomp.15Possible causep.15Actionp.15No motor sound or movement of piston rodp.15Excessive electricity consumptionp.15Motor runs but spindle does not movep.15Actuator cannot lift full loadp.15No signal from potentiometer or hall effect sensorp.15Motor runs too slowly or does not give full forcep.15Actuator cannot hold the chosen loadp.15Mounting of cablesp.16TORX 25IPp.16Accessoriesp.16Cables:p.16DRAWING APPENDIXp.17TECHLINE TM LA36:p.17LA36p.17Main groups of disposalp.18Product Metal scrap Cable scrap Electronic scrap Plastic recycling orp.18combustionp.18LA36 X X X Xp.18Label for LA36p.18
Page 1 of the Linak Linear Actuator (LA36) user manual — LA36 ACTUATOR
Page 1 · click to enlarge
Page 1

LA36 ACTUATOR

Linak Linear Actuator (LA36) — LA36 ACTUATOR diagram (page 1)
Fig. 1

To learn more about LINAK please visit: W W W. L I N A K . C O M

Page 2 of the Linak Linear Actuator (LA36) user manual — LA36 ACTUATOR
Page 2 · click to enlarge
Page 2
Page 2 of the Linak Linear Actuator (LA36) user manual — LA36 ACTUATOR
Page 3 of the Linak Linear Actuator (LA36) user manual — LA36 ACTUATOR
Page 3 · click to enlarge
Page 3
Page 3 of the Linak Linear Actuator (LA36) user manual — LA36 ACTUATOR
Page 4 of the Linak Linear Actuator (LA36) user manual — LINAK A/S
Page 4 · click to enlarge
Page 4

Preface

We are delighted that you have chosen a product from LINAK. LINAK systems are high-tech products based on many years of experience in the manufacture and development of actuators, electronic control boxes, controls, and chargers. We are also constantly improving our products to meet customer requirements.

This user manual will tell you how to install, use, and maintain your LINAK LA36 actuator.

We are sure that the LA36 actuator will give you a problemfree operation. Before our products leave the factory they undergo full function and quality testing. Should you nevertheless experience problems with your LINAK pro- ducts, you are always welcome to contact our service departments or service centres.

Most LINAK subsidiaries have authorised service centres, which are always ready to help you.

LINAK provides a warranty on all its products. This warranty, however, is subject to correct use in accordance with the specifi cations, maintenance being done correctly and any repairs being carried out at a service centre, which is authorised to repair LINAK products.

LINAK A/S

Page 5 of the Linak Linear Actuator (LA36) user manual — Safety instructions
Page 5 · click to enlarge
Page 5

Safety instructions

Please read the following safety information carefully.

Ensure that all staff who are to connect, mount, or use the actuator are in possession of the necessary information and that they have access to this user manual.

Persons who do not have the necessary experience or knowledge of the product/products must not use the product/ products. Besides, persons with reduced physical or mental abilities must not use the product/products, unless they are under surveillance or they have been thoroughly instructed in the use of the apparatus by a person who is responsible for the safety of these persons.

Moreover, children must be under surveillance to ensure that they do not play with the product.

  • Before you start mounting/dismounting, ensure that the following points are observed:
  • The actuator is not in operation.
  • The mains current supply is switched off and the plug has been pulled out.
  • The actuator is free from loads that could be released during this work.
  • Before you put the actuator into operation, check the following:
  • The actuator is correctly mounted as indicated in the relevant user instructions.
  • The equipment can be freely moved over the actuator’s whole working area.
  • The actuator is connected to a mains electricity supply/transformer with the correct voltage and which is dimensioned and adapted to the actuator in question.

During operation • Listen for unusual sounds and watch out for uneven running. Stop the actuator immediately if anything unusual is observed.

When the equipment is not in use • Switch off the mains supply or pull out the plug in order to prevent unintentional operation.

Classification The equipment is not suitable for use in the presence of a flammable anaesthetic mixture with air or with oxygen or nitrous oxide.

Page 6 of the Linak Linear Actuator (LA36) user manual — Important information
Page 6 · click to enlarge
Page 6

Important information

Information about the actuators is described under the following two headings:

Failing to follow these instructions can result in the actuator suffering damage or being ruined.

Linak Linear Actuator (LA36) — Important information diagram (page 6)
Fig. 2 · Important information
Page 7 of the Linak Linear Actuator (LA36) user manual — Important information
Page 7 · click to enlarge
Page 7
Linak Linear Actuator (LA36) — Important information diagram (page 7)
Fig. 3 · Important information
Linak Linear Actuator (LA36) — Important information diagram (page 7)
Fig. 4 · Important information
Linak Linear Actuator (LA36) — Important information diagram (page 7)
Fig. 5 · Important information
Page 8 of the Linak Linear Actuator (LA36) user manual — Misc. on the TECHLINE TM actuator system
Page 8 · click to enlarge
Page 8

Misc. on the TECHLINE TM actuator system

Warranty There is a 12 months’ warranty on the TECHLINE products against manufacturing faults calculated from the production date of the individual products (see label). LINAK’s warranty is only valid in so far as the equipment has been used and maintained correctly and has not been tampered with. Furthermore, the actuator must not be exposed to violent treatment. In the event of this, the warranty will be ineffective/invalid. For further details, please see LINAK A/S ordinary conditions of sale.

  • Maintenance
  • The actuator must be cleaned at regular intervals to remove dust and dirt and inspected for mechanical damages or wear.
  • Inspect attachment points, wires, piston rod, cabinet, and plug, as well as check that the actuator functions correctly.
  • The actuator is a closed unit and requires no internal maintenance.
  • To ensure that the pregreased inner tube remains lubricated the actuator must only be washed down when the piston rod is fully retracted.
Page 9 of the Linak Linear Actuator (LA36) user manual — End play: 2 mm maximum
Page 9 · click to enlarge
Page 9

Specifications

Motor: Permanent magnet motor 12, 24, or 36V

Motor protection: Automatic protection resets thermal overload

CableMotor: 2 x 14 AWG PVC cable Control: 6 x 20 AWG PVC cable

Gear ratio: 4 different gear ratios available in steel (2600 N/1700 N, 4500 N, and 10,000 N)

Slip clutch: Mechanical - overload protection through an integrated slip clutch is optional adjusted to 1.2-1.4 times max. load

Brake: Integrated brake ensures a high self-locking ability. The brake is deactivated when the actuator is powered in order to obtain a high effi ciency

Hand crank: As a standard feature the actuator can be operated manually

Housing: The housing is made of casted aluminium, coated for outdoor out and in harsh conditions

Spindle part: Outer tube: Extended aluminium anodised Inner tube: Stainless steel AISi304/SS2333 Acme spindle: Trapezoidal spindle with high effi ciency

Temperature range: - 30o C to +65o C - 22o F to +150o F Full performance +5o C to +40o C

End play: 2 mm maximum

Weather protection: Rated IP 66 for outdoor use. Furthermore the actuator can be washed down with a high-pressure washer.

Page 10 of the Linak Linear Actuator (LA36) user manual — Warning! LINAK’s actuators are not constructed for use within the following fields:
Page 10 · click to enlarge
Page 10

Mounting guidelines

Linak Linear Actuator (LA36) — Mounting guidelines diagram (page 10)
Fig. 6 · Mounting guidelines

LINAK® linear actuators are quickly and easily mounted by slipping pins through the holes on each end of the units and into brackets on the machine frame and the load. The mounting pins must be parallel to each other as shown in Figure 1. Pins, which are not parallel to each other, may cause the actuator to bind and be damaged.

Linak Linear Actuator (LA36) — Mounting guidelines diagram (page 10)
Fig. 7 · Mounting guidelines

The load should act along the stroke axis of the actuator since off centre loads may cause bending and lead to premature failure. See Figure 2.

Make sure the mounting pins are supported in both ends. Failure to do so could shorten the life of the actuator. Cantilever mounts are unacceptable.

RIGHT WRONG WRONG

It is the application manufacturer’s responsibility to incorporate a suitable safety arrangement, which will prevent personal injury from occurring, if the actuator should fail.

Warning! LINAK’s actuators are not constructed for use within the following fields:

  • Offshore installations
  • Aeroplanes and other aircraft
  • Explosive environments
  • Nuclear power generation
Page 11 of the Linak Linear Actuator (LA36) user manual — 6 mm Allen key
Page 11 · click to enlarge
Page 11

Application hints

The actuator is weather proof for use in outdoor applications. The actuator can be washed down with a high pressure washer, but it should not be used under water.

Optionally the actuator is overload protected with a slip clutch. The clutch will slip when the load exceeds approx. 1.2 - 1.4 times the actuators rating.

The duty cycle at max. load is 20% on time. This means if the actuator runs continuously for 20 seconds it must remain off for 80 seconds before operating again.

Manual hand crank

The manual hand crank can be used in the case of power failure.

Linak Linear Actuator (LA36) — Manual hand crank diagram (page 11)
Fig. 8 · Manual hand crank

6 mm Allen key

The cover over the Allen key socket must be unscrewed before the Allen key can be inserted and the Hand Crank operated.

Hand Crank Torque6 - 8 Nm ( 2600 N – 6800 N load )

Piston Rod movement per turn Gear A = 10.5 mm Gear B = 6.0 mm Gear C = 4.0 mm

Page 12 of the Linak Linear Actuator (LA36) user manual — Connections diagram: For 36xxxxx0H/Pxxxxxx and 36xxxxx1H/Pxxxxxx
Page 12 · click to enlarge
Page 12

Electrical installation

Motor connection

Wiring: The actuator direction (forward, reverse) is controlled with a doublethrow switch with the centre postion “off”.

+

Linak Linear Actuator (LA36) — + diagram (page 12)
Fig. 9

Actuation To extend the actuator, connect brown to positive and blue to negative. To retract the actuator, connect blue to positive and brown to negative.

Connections diagram: For 36xxxxx0H/Pxxxxxx and 36xxxxx1H/Pxxxxxx

Linak Linear Actuator (LA36) — Connections diagram: For 36xxxxx0H/Pxxxxxx and 36xxxxx1H/Pxxxxxx diagram (page 12)
Fig. 10 · Connections diagram: For 36xxxxx0H/Pxxxxxx and 36xxx…

1 2 3 3 < ! ' 4 5 4

% 4 ( , !

" # # $ % & !

' ( ) - . /

% 3 ;

Page 13 of the Linak Linear Actuator (LA36) user manual — Signal cable Connections diagram: For 36xxxxx2Hxxxxxx
Page 13 · click to enlarge
Page 13

Connections diagram: For 36xxxxx2Pxxxxxx and 36xxxxx20xxxxxx:

Linak Linear Actuator (LA36) — Connections diagram: For 36xxxxx2Pxxxxxx and 36xxxxx20xxxxxx: diagram (page 13)
Fig. 11 · Connections diagram: For 36xxxxx2Pxxxxxx and 36xxxxx…

1 2 3 3 < ! ) 4 1 4

% 4 ( , !

" # # $ % & !

% 3 ;

Signal cable Connections diagram: For 36xxxxx2Hxxxxxx

Linak Linear Actuator (LA36) — Signal cable Connections diagram: For 36xxxxx2Hxxxxxx diagram (page 13)
Fig. 12 · Signal cable Connections diagram: For 36xxxxx2Hxxxxx…

1 2 3 3 < ! ' 4 5 4

% 4 ( , !

" # # $ % & !

' ( ) - . /

% 3 ;

Page 14 of the Linak Linear Actuator (LA36) user manual — Signal cable
Page 14 · click to enlarge
Page 14

Connections diagram: For 36xxxxx3xxxxBxx + 36xxxxx40xxxBxx:

Linak Linear Actuator (LA36) — Connections diagram: For 36xxxxx3xxxxBxx + 36xxxxx40xxxBxx: diagram (page 14)
Fig. 13 · Connections diagram: For 36xxxxx3xxxxBxx + 36xxxxx40…

1 2 3 3 1 " ! 4 5 4

" # # $ % &

' ( ) - . /

Signal cable

Page 15 of the Linak Linear Actuator (LA36) user manual — Motor runs too slowly or does not give full force
Page 15 · click to enlarge
Page 15

Connection of the LA36 with the CS16

Linak Linear Actuator (LA36) — Connection of the LA36 with the CS16 diagram (page 15)
Fig. 14 · Connection of the LA36 with the CS16

1 2 3 4 5 6 7 8 9 10 11 12

R = RED . O = ORANGE . GR = GREEN

Troubleshooting

Symptom

Possible cause

Action

No motor sound or movement of piston rod

  • The actuator is not connected to the power supply
  • Cable damaged
  • Connect the actuator to the power supply
  • Change cable
  • Send actuator for repair
  • Align or reduce load
  • Send actuator for repair

Excessive electricity consumption

  • Misalignment or overload in application

Motor runs but spindle does not move

  • Gearwheel or spindle damaged
  • Send actuator for repair

Actuator cannot lift full load

  • Clutch is worn
  • Motor is damaged
  • Send actuator for repair

No signal from potentiometer or hall effect sensor

  • Cable damaged
  • Potentiometer damaged
  • Change cable
  • Send actuator for repair
  • Insufficient power supply
  • Voltage drop in cable
  • Increase power supply
  • Thicker cable

Motor runs too slowly or does not give full force

Actuator cannot hold the chosen load

  • Load is higher than specified
  • Reduce load
Page 16 of the Linak Linear Actuator (LA36) user manual — Accessories
Page 16 · click to enlarge
Page 16

Mounting of cables

TORX 25IP

Linak Linear Actuator (LA36) — Mounting of cables diagram (page 16)
Fig. 15 · Mounting of cables
Linak Linear Actuator (LA36) — Mounting of cables diagram (page 16)
Fig. 16 · Mounting of cables
  • Unscrew the cover and remove the two blind plugs
  • Plug in the power cable and/or the signal cable
  • Slide the cover onto the actuator. The torque of the cover screw is +/- 0.3 Nm

Accessories

Cables:

Power cables (Ordered separately) Order no. 1.5 m cable 0367002-1500 5 m 0367002-5000 0.2 m cable (AMP connectors) 0367006

Signal cable (Ordered separately) Order no. 1.5 m cable 0367003-1500 5 m 0367003-5000

Page 17 of the Linak Linear Actuator (LA36) user manual — DRAWING APPENDIX
Page 17 · click to enlarge
Page 17

DRAWING APPENDIX

TECHLINE TM LA36:

LA36

Linak Linear Actuator (LA36) — DRAWING APPENDIX diagram (page 17)
Fig. 17
Linak Linear Actuator (LA36) — DRAWING APPENDIX diagram (page 17)
Fig. 18
Page 18 of the Linak Linear Actuator (LA36) user manual — Label for LA36
Page 18 · click to enlarge
Page 18

Main groups of disposal

Product Metal scrap Cable scrap Electronic scrap Plastic recycling or

combustion

LA36 X X X X

LINAK’s products may be disposed of, possibly by dividing them into different waste groups for recycling or combustion.

We recommend that our product is disassembled as much as possible at the disposal and that you try to recycle it. As examples of main groups within sorting of waste we can mention the following:

Metal scrap Plastic scrap Cable scrap Combustible material and collection for recoverable resources.

Some of these main groups can be sub-divided into groups e.g. metal can be divided into steel and aluminium or plastic can be divided into ABS and PP.

Label for LA36

Linak Linear Actuator (LA36) — Label for LA36 diagram (page 18)
Fig. 19 · Label for LA36
Page 19 of the Linak Linear Actuator (LA36) user manual — Main groups of disposal
Page 19 · click to enlarge
Page 19

LINAK APPLICATION POLICY The purpose of the application policy is to defi ne areas of responsibilities in relation to applying a LINAK product defi ned as hardware, software, technical advice, etc. related to an existing or new customer application.

LINAK products as defi ned above are applicable for a wide range of applications within the Medical, Furniture, Desk, and Industry areas. Yet, LINAK cannot know all the conditions under which LINAK products will be installed, used, and operated, as each individual application is unique.

The suitability and functionality of the LINAK product and its performance under varying conditions (application, vibration, load, humidity, temperature, frequency, etc.) can only be verifi ed by testing, and shall ultimately be the responsibility of the LINAK customer using any LINAK product.

LINAK shall be responsible solely that the LINAK products comply with the specifi cations set out by LINAK and it shall be the responsibility of the LINAK customer to ensure that the specifi c LINAK product can be used for the application in question.

Page 20 of the Linak Linear Actuator (LA36) user manual — Main groups of disposal
Page 20 · click to enlarge
Page 20

FACTORIES CHINA LINAK (Shenzhen) Actuator Systems, Ltd. Phone: +86 755 8610 6656 . Fax: +86 755 8610 6990 E-mail: [email protected] . www.linak.cn

NORWAY LINAK Norge AS Phone: +47 32 82 90 90 . Fax: +47 32 82 90 98 E-mail: [email protected] . www.linak.no

INDONESIA PT. HIMALAYA EVEREST JAYA Phone: +6 221 544 8956/65 . Fax: +6 221 619 4658/1925 E-mail: hejplastic-div@centrin.net.id

DENMARK LINAK A/S . Group Headquarters Guderup Phone: +45 73 15 15 15 . Fax: +45 74 45 80 48 Fax (Sales): +45 73 15 16 13 E-mail: info@linak.com. www.linak.com

POLAND LINAK Polska Phone: +48 (22) 500 28 74 . Fax: +48 (22) 500 28 75 E-mail: dkreh@linak.com. www.linak.pl

IRAN Bod Inc. Phone+98 21 88527255 . Fax: +98 21 88514037 E-mail: [email protected] . www.bod.ir

SPAIN LINAK Actuadores S.L. Phone: +34 93 588 27 77 . Fax: +34 93 588 27 85 E-mail: [email protected] . www.linak.es

MEXICO ILSA S.A. de C.V. Phone: +[52] (55) 5388-3960 . Fax: +[52] (55) 5388-3966 E-mail: linak@ilsamexico.com. www.ilsamexico.com

SLOVAKIA LINAK Slovakia s.r.o. Phone+421 517563 414 . Fax: +421 517563 410 E-mail: [email protected] . www.linak.com

SWEDEN LINAK Scandinavia AB Phone: +46 8 732 20 00 . Fax: +46 8 732 20 50 E-mail: [email protected] . www.linak.se

RUSSIAN FEDERATION 000 FAM Phone+7 812 3319333 . Fax: +7 812 3271454 E-mail: [email protected] . www.fam-drive.ru

USA LINAK U.S. Inc. North and South American Headquarters Phone: +1 502 253 5595 . Fax: +1 502 253 5596 E-mail: info@linak-us.com. www.linak-us.com

SWITZERLAND LINAK AG Phone: +41 43 388 31 88 . Fax: +41 43 388 31 87 E-mail: [email protected] . www.linak.ch

SINGAPORE SERVO DYNAMICS PTE. Ltd. Phone: +65 6844 0288 . Fax: +65 6844 0070 E-mail: servodynamics@servo.com.sg . www.servo.com.sg

SUBSIDIARIES AUSTRALIA LINAK Australia Pty. Ltd Phone: +61 3 8796 9777 . Fax: +61 3 8796 9778 E-mail: sales@linak.com.au . www.linak.com.au

TAIWAN LINAK A/S Taiwan Representative Office Phone: +886 2 25080296 . Fax: +886 2 25080296 E-mail: info@linak.com.tw . www.linak-asia.com

SOUTH KOREA UNITEK ENG. Phone+82 2 567 0888 . Fax: +82 2 3453 1177 E-mail: unitekeng@ unitekeng.co .kr . www.unitekeng.co.kr
AUSTRIA LINAK GmbH Phone+43 2746 21036 . Fax: +43 2746 21044 www.linak.at

TURKEY LINAK A/S Turkey Representative Office Phone: +90 312 4726338-59 . Fax: +90 312 4726635 E-mail: vozen@linak.com.tr . www.linak.com.tr

UNITED ARAB EMIRATES Mechatronics Phone.: +971 4 267 4311 . Fax: +971 4 267 4312 E-mail: mechtron@emirates.net.ae www.mechatronics.ae

BELGIUM & LUXEMBOURG LINAK Actuator-Systems NV/SA Phone: +32 (0)9 230 01 09 . Fax: +32 (0)9 230 88 80 E-mail: [email protected] . www.linak.be

UNITED KINGDOM LINAK UK Limited Phone: +44(0)121 544 2211 . Fax: +44(0)121 544 2552 E-mail: sales@linak.co.uk . www.linak.co.uk

For contact details on other countries please visit www.linak.com or contact:

BRAZIL LINAK do Brasil Comércio de Atuadores Ltda. Phone: +55 (11) 6832-7070 . Fax: +55 (11) 6832-7060 E-mail: linakbrasil@ig.com.br . www.linak.com.br

DISTRIBUTORS ARGENTINA NOVOTEC ARGENTINA SRL Phone: +[54] (11) 4303-8900/89 . Fax: +[54] (11) 4032-0184 E-mail: info@novotecargentina.com www.novotecargentina.com

LINAK INTERNATIONAL Fax+45 74 45 90 10 E-mail: info@ linak.com . www.linak.com
CANADA LINAK Canada Inc. Phone+1 905 821 7727 . Fax: +1 905 821 4281 E-mail: [email protected] . www.linak.ca
COLOMBIA MEM Ltda Phone+[57] (1) 334-7666 . Fax: +[57] (1) 282-1684 E-mail: servicioalcliente@ memltda.com .co www.memltda.com.co

CZECH REPUBLIC LINAK C&S S.R.O. Phone: +420581741814 . Fax: +420581702452 E-mail: [email protected] . www.linak.cz

Copyright© LINAK . 2008.03 . MA-M9-02-205-F . LINAK A/S reserves the right to make technical alterations

DENMARK LINAK DANMARK A/S Phone: +45 86 80 36 11 . Fax: +45 86 82 90 51 E-mail: [email protected] . www.linak.dk

ESTONIA TECHTRADE OÜ Phone+ 372 50 67040
E-mail[email protected] . www.techtrade.ee
FINLAND LINAK OY Phone+358 9 8700 130 . Fax: +358 9 8700 1355 E-mail: [email protected] . www.linak.fi
FRANCE LINAK FRANCE S.A.R.L Phone+33 (0)2 4136 3434 . Fax: +33 (0)2 4136 3500 E-mail: [email protected] . www.linak.fr
GERMANY LINAK GmbH Phone+49 6043 9655 0 . Fax: +49 6043 9655 60 E-mail: [email protected] . www.linak.de

INDIA LINAK A/S India Liaison Office Phone: +91 80 2212 0015 . Fax: +91 80 2207 2186 E-mail: [email protected] . www.linak.in

IRELAND LINAK UK Limited Phone+44(0)121 544 2211 . Fax: +44(0)121 544 2552 E-mail: stephen@ linak.co .uk . www.linak.co.uk

The user is responsible for determining the suitability of LINAK products for a specifi c application.

ITALY LINAK ITALIA S.r.l. Phone: +39 02 48 46 33 66 . Fax: +39 02 48 46 82 52 E-mail: [email protected] . www.linak.it

LINAK A/S takes great care in providing accurate and up-to- date information on its products. However, due to continuing developments in order to improve its products, LINAK products are subject to frequent modifi cations and changes without prior notice. Therefore, LINAK cannot guarantee the correct and actual status of said information on its products. While LINAK uses its best efforts to fulfi l orders, LINAK cannot, for the same reasons as mentioned above, guarantee the availability of any particular product. Therefore, LINAK reserves the right to discontinue the sale of any product displayed on its website or listed in its catalogues or other written material drawn up by LINAK.

JAPAN LINAK K.K. Phone+81 45 533 0802 . Fax: +81 45 533 0803 E-mail: [email protected] . www.linak.jp

MALAYSIA LINAK A/S Asian Representative Office Phone: +60 4 210 6500 . Fax: +60 4 226 8901 E-mail: info@linak-asia.com. www.linak-asia.com

All sales are subject to the Standard Terms of Sale and Delivery for LINAK A/S. For a copy hereof, please contact LINAK.

NETHERLANDS LINAK Actuator-Systems B.V. Phone: +31 76 5 42 44 40 . Fax: +31 76 5 42 61 10 E-mail: [email protected] . www.linak.nl

NEW ZEALAND LINAK New Zealand Ltd. Phone: +64 9580 2071 . Fax: +64 9580 2072 E-mail: nzsales@linak.com.au . www.linak.co.nz

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Linak Linear Actuator (LA36)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Linak Linear Actuator (LA36)

Be the first to ask — other owners or our team will answer.

Original document

Linak Linear Actuator (LA36) manual PDF

20 pages·543 KB·Automobile Parts·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…