Liebert Mini-Mate2 Offers:
control, but your floor space says otherwise, the Liebert
Reliability:
Mini-Mate2
™ can provide the overhead answer. This
High Sensible Cooling Capacity. Unlike “comfort” air conditioners, Liebert systems are designed for the cooling requirements of electronic equipment – 80% of the capacity dedicated to the removal of dry “sensible” heat, and 20% for the control of humidity.
small areas where space is at a premium:
Network Closets VoIP IDF Telecommunications Equipment Data Processing Control Rooms Desktop Publishing Network Facilities Laboratories Other Critical Electronic Systems
Reliable. Based on a field-proven system, the Liebert Mini-Mate2 is manufactured with rugged, efficient components. To ensure 365 days x 24 hours operation at your site, each system is factory tested.
Warranty Protection. In addition to the standard one-year warranty, your Liebert Representative can offer extended warranties on the unit, compressor, parts and labor.
Preventive Maintenance Programs. Liebert factory-certified personnel provide regular inspections and service to extend the life of the system.
Liebert Spare Parts. Highest-quality parts, designed for your system, are easily available through your Liebert service representative.
The components in units are located for easy service (1 ton self-contained unit shown)
Uses Zero Floor Space. The evaporator and indoor condensing units are mounted above the dropped ceiling, requiring minimal site disturbance.

Simple Control. Split systems require simple thermostat-type wiring to controls and condensing units.
Designed For Easy Component Access. Most units can be serviced from the front.
Option Kits. Single-point power kits, sweat adapters, condensate pumps, duct adapters and other options are ordered as kits, ensuring availability of required parts and complete compatibility with your system.
Agency Listed. Standard 60Hz units are CSA Agency listed/certified to meet U.S. and Canadian safety standards, and MEA listed for New York City applications. These agency listings ensure fast, hassle-free inspection and building code approvals.


communications modules designed to interface Liebert equipment with
Low Total Cost Of Ownership:
a variety of building management systems, plus stand-alone monitoring,
High-Efficiency Compressor. The rotary or scroll compressors are both energy-efficient and rugged, to ensure continuous operation.
control and leak detection devices.
Local And Remote Monitoring Panels These units provide basic monitoring and control for a single unit or small groups of equipment either at the equipment location or to a remote site.

Advanced Monitoring Liebert SiteScan® Web offers comprehensive, centralized monitoring, control, data analysis and reporting for a full-range of computer support systems. It provides web-based site monitoring, alarm management and trending/analysis for critical sites.
Free-Cooling Option. A second cooling coil allows the system to take advantage of colder outdoor temperatures and bypass compressor operation.

Liebert Universal Monitor Liebert Controllers
Leak Detection Liebert Liqui-tect® leak detection systems alert facility personnel to the presence of leaking fluids before serious damage results. They provide quick sensing and accurate reporting of leaks below the floor, above the ceiling or at the perimeter of a room.
When water temperature goes below 45˚F, cooling switches over to Free-Cooling operation. A separate chilled water source can also be used with Air-Cooled system. Note: Special cupro-nickel free-cooling coil must be specified when applied to open cooling tower.
Liebert Liqui-tect Panel Two Channel Direct Read Leak Detection Liebert Zone Leak Detection Kits Liebert Point Leak Detection Sensor
Third Party Monitoring System Connectivity The use of open protocols allows you to interface Liebert units and monitoring systems with other types and brands of control equipment including BMS, NMS, SCADA and fire alarm systems. Protocols supported:
Fundamental Monitoring Liebert Nform™is a centralized monitoring and communications software package that combines full-scale monitoring with cost-effective deployment through the use of the existing network infrastructure. Products include:


available to fit the needs of many room cooling or spot cooling requirements.
A Variety Of Options Help You Meet Numerous Applications:
Available in 1,1.5, 2, 3, 5 & 8 ton capacities (3-stage cooling on 8-ton) Self-contained or split systems allow for fitting systems with a variety of architectures Reliable refrigeration components featuring rotary or scroll compressors with copper tube aluminum fin coils provide high-efficiency Units are fully charged with refrigerant and come standard with quick-connect fittings to reduce installation time. Available in air-cooled, water-cooled, glycol-cooled or chilled-water configurations Easy-to-use menu-driven microprocessor control Optional room sensors available Hot gas bypass for low load applications
Grille (1-1.5 tons) or Plenum (2-3 tons) that fits 2’x4’ ceiling grid for direct supply & return air distribution Fan speed and/or blower options to handle supply air ductwork with higher external static pressures Filter box or duct kits to connect to ducted sites Hot water reheat to utilize building hot water for energy savings Stainless steel electric reheat and/or canister humidifier for humidity control High-pressure chilled water systems Single-point power connection kit to facilitate close coupled evaporator & condensing unit wiring Multiple air-cooled heat rejection solutions: indoor ducted, outdoor, (standard ambient, high ambient and Quiet-Line) 2-way or 3-way water regulating valves rated for standard or high-pressure applications Unit disconnect, smoke sensor, and/or high-temp sensor options Site monitoring and communication devices to meet monitoring needs R407C refrigerant

A unique compressor staging system utilizes independent 3-ton and
5-ton circuits to provide better control of room conditions. The unit
and selects the most economical cooling stage to satisfy demand.
User-friendly wall-mount display Provides precise control of all unit functions Temperature Control Humidity Control Alarm Indication Programming Auto Restart


















High Static Pressure Option 2-3 Ton Shown
1 Some option/accessory combinations are not available.
2 For further information, please refer to www.liebert.com


Field installed single-point power kit simplifies connection and installation.
Blower





*The net capacity data has fan motor heat factored in for all ratings and the entering air condition of 72˚F (22.2˚C), 50% RH is the standard rating condition of ASHRAE 127-2001


Chilled-Water


*The net capacity data has fan motor heat factored in for all ratings and the entering air condition of 72˚F (22.2˚C), 50% RH is the standard rating condition of ASHRAE 127-2001





*The net capacity data has fan motor heat factored in for all ratings and the entering air condition of 72˚F (22.2˚C), 50% RH is the standard rating condition of ASHRAE 127-2001

Ensuring The High Availability Of Mission-Critical Data And Applications.
Emerson Network Power, the global leader in enabling business-critical continuity,
ensures network resiliency and adaptability through a family of technologies —
1050 Dearborn Drive P.O. Box 29186 Columbus, Ohio 43229 800 877 9222 Phone (U.S. & Canada Only) 614 888 0246 Phone (Outside U.S.) 614 841 6022 FAX
business-critical systems. Liebert solutions employ an adaptive architecture that
responds to changes in criticality, density and capacity. Enterprises benefit
from greater IT system availability, operational flexibility, and reduced capital
Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco (PD) Italy 39 049 9719 111 Phone 39 049 5841 257 FAX
equipment and operating costs.
Emerson Network Power Asia Pacific 7/F., Dah Sing Financial Centre 108 Gloucester Rd, Wanchai Hong Kong 852 25722201 Phone 852 28029250 FAX
24 x 7 Tech Support
800 222 5877 Phone 614 841 6755 (outside U.S.)
While every precaution has been taken to ensure accuracy and completeness in this literature, Liebert Corporation assumes no responsibility, and disclaims all liability for damages resulting from use of this information or for any errors or omissions.
© 2007 Liebert Corporation. All rights reserved throughout the world. Specifications subject to change without notice.
All names referred to are trademarks or registered trademarks of their respective owners.
® Liebert and the Liebert logo are registered trademarks of the Liebert Corporation.
SL-10500 (R12/07) Printed in USA
Emerson Network Power. The global leader in enabling Business-Critical Continuity™.
AC Power
Embedded Computing
Outside Plant
Racks & Integrated Cabinets
Connectivity
Embedded Power
Power Switching & Controls
Services
DC Power
Monitoring
Precision Cooling Surge Protection
Business-Critical Continuity, Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2007 Emerson Electric Co.
Owners and our team usually reply within a day — and your question helps the next person too.