Liebert Extender/Adapter
Table of Contents 12 sections 1.0 General · Figure 1 LBS Adapter dimensions · Figure 2 Horizontal installation · Figure 3 Vertical installation · … ShowHide
Page 1 of the Liebert Extender/Adapter user manual
Page 1 · click to enlarge
Page 1
Liebert Extender/Adapter diagram (page 1)
Fig. 1
Page 2 of the Liebert Extender/Adapter user manual
Page 2 · click to enlarge
Page 2
Page 2 of the Liebert Extender/Adapter user manual
Page 4 of the Liebert Extender/Adapter user manual
Page 4 · click to enlarge
Page 4
Page 4 of the Liebert Extender/Adapter user manual
Page 5 of the Liebert Extender/Adapter user manual — 5.25 ” (133.5mm) 1.8” (45.5mm)
Page 5 · click to enlarge
Page 5

1.0 G ENERAL

Liebert’s Load Bus Sync (LBS) Extender/Adapter for Dual Bus UPS is designed to extend the LBS function, up to 150m (492 ft.) between Liebert NX series uninterruptible power system (UPS) modules of a dual bus system (DBS). The adapter also enables a Liebert NX UPS to synchronize with other UPS models.

Figure 1 LBS Adapter dimensions

8.5” (216.2mm)

5.25 ” (133.5mm) 1.8” (45.5mm)

DY3-4ZPW

POWER ON

COM1

COM2

SWITCH

LED1

Figure 2 Horizontal installation

DY3-4ZPW

POWER ON

COM2 COM1

SWITCH

LED1

Figure 3 Vertical installation

General

Page 6 of the Liebert Extender/Adapter user manual — Figure 4 Connecting a Liebert NX to a Liebert NX
Page 6 · click to enlarge
Page 6

2.0 I NSTALLATION

2.1 Liebert NX UPS to Liebert NX UPS

! WARNING Installation by qualified electrical personnel only—hazardous voltage may be present at the UPS output connectors.

1. Connect the power cables of the adapter to the Phase A, Neutral and Ground output of each UPS. 2. Connect the LBS cable to COM1 of each LBS Signal Adapter. 3. Connect the other end of each LBS cable to X4 on the parallel board (UHW241M3) in the NX UPS. 4. Connect the communication cable (up to 492 ft. [150m]) to the COM2 interface of each LBS Signal Adapter. 5. The switch of both LBS signal adapters should be in the right position (see Figure 4).

Figure 4 Connecting a Liebert NX to a Liebert NX

Liebert Extender/Adapter — Figure 4 Connecting a Liebert NX to a Liebert NX diagram (page 6)
Fig. 2 · Figure 4 Connecting a Liebert NX to a Liebert NX

up to 492 ft. (150m)

Installation · Communication Cable

Page 7 of the Liebert Extender/Adapter user manual — Table 3 Part number description
Page 7 · click to enlarge
Page 7

2.2 Liebert NX UPS to Non-Liebert NX UPS

! WARNING Installation by qualified electrical personnel only—hazardous voltage may be present at the UPS output connectors.

1. Connect the power cables of the adapter to the Phase A, Neutral and Ground Output of each UPS. 2. Connect the LBS cable to COM1 of the LBS Signal Adapter connected to the Liebert NX. 3. Connect the other end of the LBS cable to X4 on the parallel board (UHW241M3) in the NX UPS. 4. Connect the communication cable (up to 492 ft. [150m]) to the COM2 interface of each LBS Signal Adapter. 5. The switches of LBS signal adapters connected to the Liebert NX should be in the right position and the switches of LBS signal adapters connected to the non-NX UPS should be in the left position (see Figure 5).

Figure 5 Connecting a Liebert NX to a non-NX UPS

Liebert Extender/Adapter — Figure 5 Connecting a Liebert NX to a non-NX UPS diagram (page 7)
Fig. 3 · Figure 5 Connecting a Liebert NX to a non-NX UPS

up to 492 ft. (150m)

Table 1 Human interface—indicators and switches

Liebert Extender/Adapter — Table 1 Human interface—indicators and switches diagram (page 7)
Fig. 4 · Table 1 Human interface—indicators and switches

Power port Connect to Phase A, Neutral and Ground of output of UPS.

LED1 (red) Power LED. It illuminates when the power is on, turns off when the power fails.

COM1 LBS Signal interface. Connect to NX series UPS unit.

RS485 interface. Connect to other Signal Adapter. Green LED: Communication Power is OK. Yellow LED: Adapter is connected to Non NX series UPS.

SWITCH Switch to left: Connect to Non-NX series UPS unit. Switch to right: Connect to NX series UPS unit.

Table 2 Electrical rating

DescriptionRating Voltage120V-277VAC Frequency45-65HZ Current0.2A Max

Table 3 Part number description

Liebert Extender/Adapter — Table 3 Part number description diagram (page 7)
Fig. 5 · Table 3 Part number description
DescriptionPart Number 150 Meter KitNX150MLBSKIT 50 Meter KitNX050MLBSKIT

Installation · Communication Cable

Page 8 of the Liebert Extender/Adapter user manual — The Company Behind the Products
Page 8 · click to enlarge
Page 8

The Company Behind the Products

Technical Support/Service

With over a million installations around the globe, Liebert is the world leader in computer protection systems. Since its founding in 1965, Liebert has developed a complete range of support and protection systems for sensitive electronics:

Web Site www.liebert.com

Monitoring 800-222-5877 monitoring@liebert.com Outside the US: 614-841-6755

  • Environmental systems–close-control air conditioning from 1 to 60 tons

800-222-5877 upstech@liebert.com Outside the US: 614-841-6755

  • Power conditioning and UPS with power ranges from 300 VA to more than 1000 kVA
  • Integrated systems that provide both environmental and power protection in a single, flexible package

800-543-2378 powertech@liebert.com

  • Monitoring and control–from systems of any size or location, on-site or remote
  • Service and support through more than 100 service centers around the world and a 24/7 Customer Response Center

Outside the United States

614-888-0246 Locations United States 1050 Dearborn Drive P.O. Box 29186 Columbus, OH 43229

While every precaution has been taken to ensure the accuracy and completeness of this literature, Liebert Corporation assumes no responsibility and disclaims all liability for damages resulting from use of this information or for any errors or omissions.

Italy Via Leonardo Da Vinci 8 Zona Industriale Tognana 35028 Piove Di Sacco (PD) +39 049 9719 111 Fax: +39 049 5841 257

© 2006 Liebert Corporation All rights reserved throughout the world. Specifications subject to change without notice.

® Liebert and the Liebert logo are registered trademarks of Liebert Corporation. All names referred to are trademarks or registered trademarks of their respective owners.

Asia 7/F, Dah Sing Financial Centre 108 Gloucester Road, Wanchai Hong Kong 852 25722201 Fax: 852 28029250

SL-25247 (2/06) Rev. 0

Emerson Network Power. The global leader in enabling Business-Critical Continuity. EmersonNetworkPower.com

Connectivity DC Power Systems

Power Protection Integrated Cabinet Solutions

Precision Cooling Site Monitoring and Services

Emerson Network Power and the Emerson Network Power logo are trademarks and service marks of Emerson Electric Co. ©2005 Emerson Electric Co.

Show 7 more labels / short text on this page
Single-Phase UPS · Three-Phase UPS · Environmental Systems · 800-543-2778 · AC Power Systems · Embedded Power · Outside Plant
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Liebert Extender/Adapter

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Liebert Extender/Adapter

Be the first to ask — other owners or our team will answer.

Original document

Liebert Extender/Adapter manual PDF

8 pages·313 KB·Network Card·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…