Page 1 of the Liebert Precision Air Conditioner (CW041) user manual — WIRING LOOP
Page 1 · click to enlarge
Page 1

LIEBERT EC FAN LOWERING PROCEDURE & BLOCK OFF PANEL KIT INSTALLATION

DOWNFLOW MODELS WITH EC FANS

Liebert Precision Air Conditioner (CW041) — DOWNFLOW MODELS WITH EC FANS diagram (page 1)
Fig. 1

LIEBERT CW041 UNIT SHOWN WITH LIEBERT 24" FLOORSTAND. CUSTOMER UNIT MAY APPEAR DIFFERENT. READ USER MANUAL AND INSTRUCTION SHEET 195788 BEFORE RE-POSITIONING THE FAN MODULES.

Liebert Precision Air Conditioner (CW041) — DOWNFLOW MODELS WITH EC FANS diagram (page 1)
Fig. 2

A DETAIL A JACK LOCATION

TOOLS NEEDED: 1/2" HEX SOCKET & WRENCH FACTORY SUPPLIED JACK, CRANK AND JACK SUPPORT CABLE TIE CUTTER LOWERING PROCEDURE (24" FLOOR HEIGHT MINIMUM):

1. REMOVE THE MIDDLE AND BOTTOM PANELS FROM THE FRONT OF THE UNIT.
2. FOR EASE OF FAN LOWERING, REMOVAL OF THE HUMIDIFIER PAN IS RECOMMENDED.
Liebert Precision Air Conditioner (CW041) — A DETAIL A JACK LOCATION diagram (page 1)
Fig. 3

FAN DECK

3. POSITION THE FACTORY SUPPLIED JACK AND JACK SUPPORT UNDER THE FAN MODULE TO BE LOWERED. USING THE CRANK, RAISE THE JACK TO SAFELY SUPPORT THE FAN BEFORE REMOVING ANY HARDWARE. NOTE: A PROPERLY POSITIONED JACK WILL BE CENTERED BETWEEN THE FIRST AND SECOND SET OF TABS ON THE JACK SUPPORT.

"Z" BRACKET LOCATION ON CW026 - CW060

4. CUT & REMOVE THE CABLE TIE THAT RETAINS THE WIRING LOOP TO THE BLOWER MOUNTING PLATE. ALL OTHER CABLE TIES THAT ROUTE THE FAN WIRING SHOULD REMAIN INTACT.

"Z" BRACKET LOCATION ON CW076 - CW114 "Z" BRACKET

5. REMOVE THE SIX HEX-HEAD SCREWS AND "Z" BRACKETS USING A 1/2" HEX SOCKET OR WRENCH. RETAIN HARDWARE FOR LATER STEPS. "Z" BRACKETS NOT PRESENT ON LIEBERT DS, CW146 AND CW181.

SECTION B-B

WIRING LOOP

TOP VIEW OF FAN DECK

DPN002037 REV 5 REV 7/10 PAGE 1 OF 3

Page 2 of the Liebert Precision Air Conditioner (CW041) user manual — FAN DECK AND SIDE PANELS
Page 2 · click to enlarge
Page 2
Liebert Precision Air Conditioner (CW041) — 6 6 FAN MODULE RESTING ON FRAME diagram (page 2)
Fig. 4
Liebert Precision Air Conditioner (CW041) — 6 6 FAN MODULE RESTING ON FRAME diagram (page 2)
Fig. 5

6 6 FAN MODULE RESTING ON FRAME

6. USING THE FACTORY SUPPLIED JACK AND CRANK, LOWER THE FAN MODULE UNTIL IT RESTS ON THE FRAME OF THE UNIT. USE CAUTION TO PREVENT DAMAGE TO THE FAN WIRE HARNESS.
7. CW026, CW038, CW041, CW076 THRU CW114 MODELS: USING THE HARDWARE REMOVED IN STEP 5, RE-INSTALL "Z" BRACKETS WITH HEX-HEAD SCREWS TO RETAIN FAN MODULE IN THE FULLY LOWERED POSITION.
Liebert Precision Air Conditioner (CW041) — 6 6 FAN MODULE RESTING ON FRAME diagram (page 2)
Fig. 6

CW051 AND CW060 MODELS: USE THE HEX-HEAD SCREWS REMOVED IN STEP 5 TO SECURE THE FAN MODULE DIRECTLY TO THE CENTER FRAME SUPPORT. SCREW CLEARANCE HOLES ARE PROVIDED IN THE FAN MODULE. THE "Z" BRACKETS WILL ONLY BE USED TO SECURE THE FAN AT THE OUTTER ATTACHMENT POINT.

"Z" BRACKETS

LIEBERT DS, CW146 AND CW181 MODELS: USE THE HEX HEAD SCREWS REMOVED IN STEP 5 TO SECURE THE FAN MODULE DIRECTLY TO THE FRAME. SCREW CLEARANCE HOLES ARE PROVIDED IN THE FAN MODULE.

SECTION C-C

FAN DECK AND SIDE PANELS

NOT SHOWN IN THIS VIEW

8. REPEAT STEPS 3-7 TO LOWER REMAINING FAN MODULE(S) IF PRESENT.

DPN002037 REV 5 REV 7/10 PAGE 2 OF 3

Page 3 of the Liebert Precision Air Conditioner (CW041) user manual — FASTENERS
Page 3 · click to enlarge
Page 3

LIEBERT CW EC FAN BLOCK OFF PANEL KIT INSTALLATION

R

DOWNFLOW MODELS CW026 THRU CW084 AND CW106, CW114 WITH EC FANS

LIEBERT CW041 UNIT SHOWN WITH LIEBERT FLOORSTAND. CUSTOMER UNIT MAY APPEAR DIFFERENT. READ USER MANUAL SL-18057 AND INSTALLATION INSTRUCTION SHEET 301271P1 BEFORE INSTALLING BLOCK OFF PANEL KIT. SEE INSTALLATION INSTRUCTION SHEET 301271P1 FOR SPECIFIC BLOCK OFF KIT PART NUMBERS.

Liebert Precision Air Conditioner (CW041) — R diagram (page 3)
Fig. 7
Liebert Precision Air Conditioner (CW041) — R diagram (page 3)
Fig. 8

FASTENERS

BLOCKOFF PANEL

APPLICATION: FOR UNITS UTILIZING OPTIONAL BLOCK OFF KIT WITH FANS OPERATED IN THE UP POSITION (FANS IN UNIT).

REFER TO BLOCK OFF PANEL KIT INSTALLATION INSTRUCTIONS 301271P1 FOR DETAILED INSTALLATION PROCEDURE.

DPN002037 REV 5 REV 7/10 PAGE 3 OF 3

Ask about the Liebert Precision Air Conditioner (CW041)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Liebert Precision Air Conditioner (CW041)

Be the first to ask — other owners or our team will answer.

Original document

Liebert Precision Air Conditioner (CW041) manual PDF

3 pages·326 KB·Sewing Machine·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…