EN
LevelOne logo
Official user manual

LevelOne Network Camera (WCS-2030)

78 pages·3.4 MB·Network Camera·PDF·ENDEFRITNLJA
LevelOne Network Camera (WCS-2030)
Table of Contents 80 sections LevelOne · WCS-2030 · 11g Wireless IP Network Camera · User’s Manual · … ShowHide
LevelOnep.1WCS-2030p.111g Wireless IP Network Camerap.1User’s Manualp.1Before You Use This Productp.5Warning Before Installp.6Package Contentsp.8Installationp.9Hardware installationp.9To install in Ethernetp.9To install in wireless LANp.10Software installationp.11Using Installation Wizardp.17User Interfacep.17Action buttonsp.18Function buttonsp.19Setupp.20System Settingp.20Change root passwordp.21Adjust date and timep.22Network Settingp.22Fix the IP addressp.23Basic Network Settingsp.23Upgradep.24Device Informationp.24Package Informationp.25File Selectionp.26How to Usep.27Authenticationp.27Installing plug-inp.28Primary user’s capabilityp.30Main Screen with Camera Viewp.30Digital Zoomp.31Snapshotp.32Client settingsp.33Administrator’s capabilityp.35Fine-tuning for Best Performancep.35For Best Real-time Video Imagesp.35Only Quality Images Will Dop.36Somewhere Between Real-time and Clear Imagesp.36Opening accounts for new usersp.37Protect Network Camera by passwordsp.37More flexible options for viewers ○ 4p.37Change homepage layoutp.38How to change the font colorp.39How to change the backgroundp.39How to design my own homepage to replace the current onep.41Build a multimedia web attraction sitep.43Demo on multiple sites – mid-scale servicep.43Product demo for e-business – large-scale servicep.43Build a security applicationp.46Software revision upgradep.47Definitions in Configurationp.48System parametersp.49Security settingsp.50Network settingsp.51Generalp.51HTTPp.51Streamingp.51WLAN Configurationp.52Mail & FTPp.53SMTPp.53FTPp.54DDNS and UPnP settingsp.55Video codec parametersp.55Motion detectionp.57Application settingsp.58Weekly schedulep.58Send out the snapshot while motion detectionp.58Sequential operationp.58Homepage layout settingsp.60Viewing system logp.61Viewing system parametersp.61Factory defaultp.61Appendixp.62A. Troubleshootingp.62Status LEDp.62Reset and restorep.62B. Frequently asked questionsp.62C. URL commands of the Network Camerap.66
Page 1 of the LevelOne Network Camera (WCS-2030) user manual — User’s Manual
Page 1 · click to enlarge
Page 1
LevelOne Network Camera (WCS-2030) — LevelOne diagram (page 1)
Fig. 1 · LevelOne

LevelOne

WCS-2030

11g Wireless IP Network Camera

LevelOne Network Camera (WCS-2030) — LevelOne diagram (page 1)
Fig. 2 · LevelOne

User’s Manual

Page 2 of the LevelOne Network Camera (WCS-2030) user manual — LevelOne
Page 2 · click to enlarge
Page 2
Page 2 of the LevelOne Network Camera (WCS-2030) user manual — LevelOne
Page 3 of the LevelOne Network Camera (WCS-2030) user manual — LevelOne
Page 3 · click to enlarge
Page 3
Page 3 of the LevelOne Network Camera (WCS-2030) user manual — LevelOne
Page 4 of the LevelOne Network Camera (WCS-2030) user manual — LevelOne
Page 4 · click to enlarge
Page 4
Page 4 of the LevelOne Network Camera (WCS-2030) user manual — LevelOne
Page 5 of the LevelOne Network Camera (WCS-2030) user manual — Before You Use This Product
Page 5 · click to enlarge
Page 5

Before You Use This Product

The use of surveillance devices may be prohibited by law in your country. The Network

Camera is not only a high-performance web-ready camera but also can be part of a

flexible surveillance system. It is the user’s responsibility to ensure that the operation

of such devices is legal before installing this unit for its intended use.

It is important to first verify that all contents received are complete according to the list

in the "Package Contents" chapter. Take notice of the warnings in “Quick installation

guide” before the Network Camera is installed, then carefully read and follow the

instructions in the “Installation” chapter to avoid damages due to faulty assembly and

installation. This also ensures the product is used properly as intended.

The Network Camera is a network device and its use should be straightforward for

those who have basic network knowledge. The “Troubleshooting” chapter in the

Appendix provides remedies to the most common errors in set up and configuration.

You should consult this chapter first if you run into a system error.

The Network Camera is designed for various applications including video sharing,

general security/surveillance, etc. The “How to Use” chapter suggests ways to best

utilize the Network Camera and ensure proper operations. For the creative and

professional developers, the "URL Commands of The Network Camera " chapter serves

to be a helpful reference to customize existing homepages or integrating with the

current web server.

For paragraphs preceded by

the reader should use caution to understand

completely the warnings. Ignoring the warnings may result in serious hazards or

injuries.

Page 6 of the LevelOne Network Camera (WCS-2030) user manual — Warning Before Install
Page 6 · click to enlarge
Page 6

Warning Before Install

LevelOne Network Camera (WCS-2030) — Warning Before Install diagram (page 6)
Fig. 3 · Warning Before Install
Page 7 of the LevelOne Network Camera (WCS-2030) user manual — Warning Before Install
Page 7 · click to enlarge
Page 7
LevelOne Network Camera (WCS-2030) — Warning Before Install diagram (page 7)
Fig. 4 · Warning Before Install
Page 8 of the LevelOne Network Camera (WCS-2030) user manual — Package Contents
Page 8 · click to enlarge
Page 8

Package Contents

LevelOne Network Camera (WCS-2030) — Package Contents diagram (page 8)
Fig. 5 · Package Contents
Page 9 of the LevelOne Network Camera (WCS-2030) user manual — To install in Ethernet
Page 9 · click to enlarge
Page 9

Installation

In this manual, "User" refers to whoever has access to the Network Camera, and

"Administrator" refers to the person who can configure the Network Camera and grant

user access to the camera.

Hardware installation

LevelOne Network Camera (WCS-2030) — Hardware installation diagram (page 9)
Fig. 6 · Hardware installation

Please verify that your product package contains all the

accessories listed in the foregoing Package Contents.

Depending on the user’s application, an Ethernet cable may

be needed. The Ethernet cable should meet the specs of UTP

Category 5 and not exceed 100 meters in length.

Connect the power adapter jack to the Network Camera

before plugging in to the power socket. This will reduce the

risk of accidental electric shock.

Upon powering up, the device runs through a self-test procedure and the front LEDs

will blink between green and red a few times. If self-test passes, the LED will be green

and the Network Camera will standby for getting IP address. After getting IP Address,

the LED will blink green every second. If self-test fails the red LED will blink several

times. Refer to Appendix A for troubleshooting.

The Network Camera will first detect Ethernet. If it does not connect to Ethernet, the

Network Camera will try WLAN. During the searching and connecting process to the

wireless access point or station, the red LED of the Network Camera will flash every

second. Until the Network Camera connects to the other wireless device, the red LED

will become lighted. Operating in either network mode, the green LED will flash every

second as heartbeat to indicate alive.

To install in Ethernet

Make sure the Ethernet is firmly connected to a switch hub. After attaching the

Ethernet cable plug in the power adapter. If the LED turns out to be steady green after

self-test, go to next paragraph “Software installation”. If the Ethernet is not available,

Network Camera will switch to wireless LAN mode.

Page 10 of the LevelOne Network Camera (WCS-2030) user manual — To install in wireless LAN
Page 10 · click to enlarge
Page 10

To install in wireless LAN

If the Ethernet is not available while power on, the Network Camera will search for any

access point with the SSID “default”. Once any access point is found, the LED will turn

green to wait for installation. If the network environment cannot meet the default

settings, install Network Camera in Ethernet to proceed with wireless LAN

configuration.

Page 11 of the LevelOne Network Camera (WCS-2030) user manual — Software installation
Page 11 · click to enlarge
Page 11

Software installation

The following are steps for the software installation.

STEP 1 Put the Installation disk into the CD-ROM drive, and the installation should

start automatically. If the installation does not start, click on “Start” on the lower left

corner of your screen, open “My Computer” and double click on the CD-ROM icon. The

Installation Wizard Installation Window will appear.

LevelOne Network Camera (WCS-2030) — Software installation diagram (page 11)
Fig. 7 · Software installation
Page 12 of the LevelOne Network Camera (WCS-2030) user manual — Software installation
Page 12 · click to enlarge
Page 12

STEP 2 There are links on this page, including Install Software, User’s Manual and

Customer Homepage. Click on “Install Software” to enter Install Software page.

LevelOne Network Camera (WCS-2030) — Software installation diagram (page 12)
Fig. 8 · Software installation
Page 13 of the LevelOne Network Camera (WCS-2030) user manual — Software installation
Page 13 · click to enlarge
Page 13

STEP 3 There are links on this page, including Installation Wizard, User’s Manual and

Surveillance Software. Click on “Installation Wizard” to launch the setup program.

LevelOne Network Camera (WCS-2030) — Software installation diagram (page 13)
Fig. 9 · Software installation
Page 14 of the LevelOne Network Camera (WCS-2030) user manual — Software installation
Page 14 · click to enlarge
Page 14

STEP 4 Select the installation directory for this application software and click on “Next”.

You can also change the installation directory from the default directory by clicking on

LevelOne Network Camera (WCS-2030) — Software installation diagram (page 14)
Fig. 10 · Software installation

“Browse…”

Page 15 of the LevelOne Network Camera (WCS-2030) user manual — Software installation
Page 15 · click to enlarge
Page 15

STEP 5 Select a program folder to install the application software into and then click on

“Next”.

LevelOne Network Camera (WCS-2030) — Software installation diagram (page 15)
Fig. 11 · Software installation
Page 16 of the LevelOne Network Camera (WCS-2030) user manual — Software installation
Page 16 · click to enlarge
Page 16

STEP 6 Click on “Finish” to finish installation. This completes the installation.

LevelOne Network Camera (WCS-2030) — Software installation diagram (page 16)
Fig. 12 · Software installation
Page 17 of the LevelOne Network Camera (WCS-2030) user manual — User Interface
Page 17 · click to enlarge
Page 17

Using Installation Wizard

User Interface

Once you run the Installation Wizard, you will see the user interface. You can click on

the device list to select a device. The three buttons (Setup, Upgrade, and Reset to

default) won’t be enabled until you select at least one device.

LevelOne Network Camera (WCS-2030) — User Interface diagram (page 17)
Fig. 13 · User Interface

Installation wizard allows you to setup or upgrade multiple devices (of the same model)

at the same time. If you selected different models, then the buttons will be disabled.

There are five buttons on the bottom of the main page, and five buttons on the left

panel of the main page.

LevelOne Network Camera (WCS-2030) — User Interface diagram (page 17)
Fig. 14 · User Interface
Page 18 of the LevelOne Network Camera (WCS-2030) user manual — Action buttons
Page 18 · click to enlarge
Page 18
LevelOne Network Camera (WCS-2030) — Action buttons diagram (page 18)
Fig. 15 · Action buttons
LevelOne Network Camera (WCS-2030) — Action buttons diagram (page 18)
Fig. 16 · Action buttons

Action buttons

Click on this button to clean up the device list and search all devices on the

within the same subnet again. It will take about 5 seconds.

To setup or upgrade the devices which can not be found by Installation

Wizard, please click on this button to add them manually. Click on this

button will popup a dialog. You can input the IP address and click on Ok to add the

device into the device list.

LevelOne Network Camera (WCS-2030) — Action buttons diagram (page 18)
Fig. 17 · Action buttons

Click on this button will remove all the selected devices from the device list.

The devices that you remove might be show up again if you click the search

button or add them into list manually.

While you selected several devices, this button allows you to uncheck all

the selected devices by one click instead of uncheck the selected devices

one by one.

Click on this button will open the web browsers to link to all the

selected devices. (One browser per device)

Page 19 of the LevelOne Network Camera (WCS-2030) user manual — Function buttons
Page 19 · click to enlarge
Page 19

Function buttons

Click on this button to modify the settings of the selected devices. For

more detail, please refer to Upgrade.

Click on this button to upgrade the firmware of the selected devices. For

more detail, please refer to Upgrade.

Click on this button to reset the selected devices to default settings.

Click on this button to close the Installation Wizard.

Click on this button to get information about the Installation Wizard.

Page 20 of the LevelOne Network Camera (WCS-2030) user manual — System Setting
Page 20 · click to enlarge
Page 20

Setup

When you select one or multiple devices (of the same model) , the “Setup” button will

be enabled. Click on it to modify the settings of the selected device(s). After clicking on

the “Setup” button, Installation Wizard will try to connect to the selected device(s). If

the authentication is failed, it will popup a dialog) to ask for correct password and http

port number.

The default password is the MAC address of your own FCS-1030, which marks at the

bottom label of each device.

LevelOne Network Camera (WCS-2030) — Setup diagram (page 20)
Fig. 18 · Setup

Please enter the MAC address with capital letters.

System Setting

After connected to the selected device(s), it will switch to system setting page.

Click on this button to back to the previous page or main page

Click on this button to keep the settings and go to the next page.

Click on this button to discard the settings of the current page and go to

the next page.

Page 21 of the LevelOne Network Camera (WCS-2030) user manual — Change root password
Page 21 · click to enlarge
Page 21

Change root password

To change the administrator’s password, type the new password in both root password

and confirm password text boxes identically. What is typed will be displayed as

asterisks for security purposes. The maximum password is 14 characters.

LevelOne Network Camera (WCS-2030) — Change root password diagram (page 21)
Fig. 19 · Change root password
Page 22 of the LevelOne Network Camera (WCS-2030) user manual — Network Setting
Page 22 · click to enlarge
Page 22

Adjust date and time

There are three ways to adjust system date and time. The easiest way is to make

Network Camera "Sync with computer time". The second way “Manual” is to set the

date and time manually by entering new values. Notice the format in the related field

while typing. The third way “Automatic” is to make Network Camera automatically

synchronize with timeservers over the Internet every hour.

Network Setting

In this page, you can change the server’s IP address, subnet mask, default router,

primary dns, and secondary dns.

Page 23 of the LevelOne Network Camera (WCS-2030) user manual — Basic Network Settings
Page 23 · click to enlarge
Page 23
LevelOne Network Camera (WCS-2030) — Fix the IP address diagram (page 23)
Fig. 20 · Fix the IP address

Fix the IP address

Check "Reset IP address at next boot" will force Network Camera to reconfigure its

IP address whenever it reboot. If you want the Network Camera to use a fixed IP,

please uncheck the "Reset IP address at next boot" and assign a valid IP address.

If you select more than one device, changing the IP address is not allowed and the IP

address field will be disabled.

Basic Network Settings

You can setup the network setting by this page. Usually this is no need to be changed,

if you do change it please make sure you input the correct setting or the device may not

Page 24 of the LevelOne Network Camera (WCS-2030) user manual — Device Information
Page 24 · click to enlarge
Page 24

be reachable.

Upgrade

When you select one device or multiple devices (of the same model), the “Upgrade”

button will be enabled. Click on it to upgrade the firmware of the selected device(s).

After click on the “Upgrade” button, Installation Wizard will try to connect the

selected device(s). If the authentication is failed, it will popup a dialog to ask for the

correct password and http port number.

The default password is the MAC address of your own FCS-1030, which marks at the

bottom label of each device.

LevelOne Network Camera (WCS-2030) — Upgrade diagram (page 24)
Fig. 21 · Upgrade

Please enter the MAC address with capital letters.

Device Information

After connected to the selected device, it will display.

LevelOne Network Camera (WCS-2030) — Device Information diagram (page 24)
Fig. 22 · Device Information
Page 25 of the LevelOne Network Camera (WCS-2030) user manual — Package Information
Page 25 · click to enlarge
Page 25
LevelOne Network Camera (WCS-2030) — Package Information diagram (page 25)
Fig. 23 · Package Information

Package Information

The package information will show the information about the file that you selected.

Firmware version: The version number of the selected firmware.

Supported script version: The maximum script version that firmware can support.

Web page version: The version number of the web page.

Script version: Script version used by web page and server script.

Viewer plugin version: The version number of the viewer plugin.

Upgrade plugin versionThe version number of the upgrade plugin

Supported language: The language that the selected file supports.

Page 26 of the LevelOne Network Camera (WCS-2030) user manual — Upgrade
Page 26 · click to enlarge
Page 26

File Selection

You can use the file combolist to browse the file that you want upgrade onto the

selected device(s). After selecting the file, Installation Wizard will check whether the

file you selected is correct. If it is correct, then the package information will display the

information about the file and enable the “Upgrade” button. Therefore you can click

on the button to upgrade the firmware. If it is not correct, then it will popup a warning

message.

Upgrade

Click on the “Upgrade” button to upgrade the firmware of the selected device(s). It

will popup the dialog to show the progress of the upgrading process.

LevelOne Network Camera (WCS-2030) — Upgrade diagram (page 26)
Fig. 24 · Upgrade

After the upgrade process is done. Click “Done” to finish.

LevelOne Network Camera (WCS-2030) — Upgrade diagram (page 26)
Fig. 25 · Upgrade
Page 27 of the LevelOne Network Camera (WCS-2030) user manual — Authentication
Page 27 · click to enlarge
Page 27

How to Use

Authentication

After opening the Web browser and typing in the URL of the Network Camera, a

dialogue window pops up to request a username and password. Upon successful

authentication, the following figure is displayed.

The foreground is the login window and the background shows the message if

authentication fails. The user may check the option box to save the password for future

convenience. This option is not available to the Administrator for obvious reason.

After successful linkage, the authentication window should pop up.

The default user name is root.

The default password is the MAC address of your own FCS-1030, which marks at the

bottom label of each device.

Please enter the MAC address with capital letters.

Page 28 of the LevelOne Network Camera (WCS-2030) user manual — Installing plug-in
Page 28 · click to enlarge
Page 28
LevelOne Network Camera (WCS-2030) — Installing plug-in diagram (page 28)
Fig. 26 · Installing plug-in

Installing plug-in

For the initial access to the Network Camera in Windows, the web browser may prompt

for permission to install a new plug-in for the Network Camera. Permission request

depends on the Internet security settings of the user’s PC or notebook. If the highest

security level is set, the computer may prohibit any installation and execution attempt.

This plug-in has been registered for certificate and is used to display the video in the

browser. Users may click on

to proceed. If the web browser does not allow the

user to continue to install, check the Internet security option and lower the security

levels or contact your IT or networking supervisor for help.

Page 29 of the LevelOne Network Camera (WCS-2030) user manual — Installing plug-in
Page 29 · click to enlarge
Page 29
LevelOne Network Camera (WCS-2030) — Installing plug-in diagram (page 29)
Fig. 27 · Installing plug-in
Page 30 of the LevelOne Network Camera (WCS-2030) user manual — Main Screen with Camera View
Page 30 · click to enlarge
Page 30

Primary user’s capability

Main Screen with Camera View

The main page layout has two parts:

Configuration functions: The camera can be configured using these user interfaces.

Camera View: What the camera sees.

Click on the configuration link to the left of the image window to enter the configuration

page.

LevelOne Network Camera (WCS-2030) — Main Screen with Camera View diagram (page 30)
Fig. 28 · Main Screen with Camera View
Page 31 of the LevelOne Network Camera (WCS-2030) user manual — Digital Zoom
Page 31 · click to enlarge
Page 31

Digital Zoom

Click on the magnifier icon under the camera view then the digital zoom control panel

will be shown. Uncheck “Disable digital zoom” and use the slider control to change the

zoom factors.

LevelOne Network Camera (WCS-2030) — Digital Zoom diagram (page 31)
Fig. 29 · Digital Zoom
Page 32 of the LevelOne Network Camera (WCS-2030) user manual — Snapshot
Page 32 · click to enlarge
Page 32

Snapshot

Click on “Snapshot”, web browser will pop up a new window to show the snapshot.

Users can point at the snapshot and click the right button of mouse to save it.

LevelOne Network Camera (WCS-2030) — Snapshot diagram (page 32)
Fig. 30 · Snapshot
Page 33 of the LevelOne Network Camera (WCS-2030) user manual — Client settings
Page 33 · click to enlarge
Page 33

Client settings

At the initial access to the “Connection type” page in Windows, the web browser will ask

for a new plug-in installation, the plug-in being the Network Camera. This plug-in has

been registered for certification and can be used to change the parameters at the

client’s site. The user may click on

to install the plug-in. If the web browser

does not allow the user to complete the installation, check the Internet security to

lower the security level or contact your IT or networking supervisor.

LevelOne Network Camera (WCS-2030) — Client settings diagram (page 33)
Fig. 31 · Client settings

There are two settings for the client side. One is “Media Option” for users to

determine if audio should be muted. The other is “Protocol Option” which allows

choices on connection protocol between client and server. There are three protocols

choices to optimize your usage - UDP, TCP and HTTP.

The UDP protocol allows for more real-time audio and video streams. However, some

Page 34 of the LevelOne Network Camera (WCS-2030) user manual — Client settings
Page 34 · click to enlarge
Page 34

packets may be lost due to network burst traffic and images may be obscured.

The TCP protocol allows for less packet loss and produces a more accurate video

display. The downside with this protocol is that the real-time effect is worse than that

with the UDP protocol.

The HTTP protocol must be selected if the network is protected by a firewall and it only

allows HTTP Port (80) to be opened. In this mode, audio will not be sent and only video

is operational. If no special need is required, UDP protocol is recommended. Generally

speaking, the client’s choice will be in the order of UDP → TCP → HTTP. After the

Network Camera is connected successfully, “Protocol Option” will indicate the selected

protocol. The selected protocol will be recorded in the user's PC and will be used for the

next connection. If the network environment is changed, or the user wants to let the

web browser to detect again, manually select the UDP protocol, save, and return HOME

to re-connect.

LevelOne Network Camera (WCS-2030) — Client settings diagram (page 34)
Fig. 32 · Client settings

http://<Network Camera>/protocol.html

is the domain name or the original IP address of the Network

Camera.

Page 35 of the LevelOne Network Camera (WCS-2030) user manual — For Best Real-time Video Images
Page 35 · click to enlarge
Page 35

Administrator’s capability

Fine-tuning for Best Performance

Best performance generally equates to the fastest image refresh rate with the best

video quality, and at the lowest network bandwidth as possible. The three factors,

“Maximum frame rate”, “Fix bit rate”, and “Fix quality” on the Video Configuration page,

are correlative to allow for achieving the best performance possible.

LevelOne Network Camera (WCS-2030) — Fine-tuning for Best Performance diagram (page 35)
Fig. 33 · Fine-tuning for Best Performance

For Best Real-time Video Images

To achieve good real-time visual effect, the network bandwidth should be large enough

to allow a transmission rate of greater than 20 image frames per second. If the

broadband network is over 1 Mbps, set the “Fix bit rate” to 1000Kbps or 1200Kbps, and

set “Fix quality” at the highest quality. The maximum frame rate is 30. If your network

bandwidth is more than 384Kbps, you can fix the bit rate according to your bandwidth

Page 36 of the LevelOne Network Camera (WCS-2030) user manual — Somewhere Between Real-time and Clear Images
Page 36 · click to enlarge
Page 36

and set the maximum frame rate to 30 fps. If the images vary dramatically in your

environment, you may want to slow the maximum frame rate down to 20 fps in order

to lower the rate of data transmission. This allows for better video quality and the

human eyes cannot readily detect the differences between those of 20, 25, or 30

frames per second. If your network bandwidth is below 384 Kbps, set the “Fix bit rate”

according to your bandwidth and try to get the best performance by fine-tuning with

the “Maximum frame rate”. In a slow network, greater frame rate results in blur images.

Another work-around is to choose “Half” in the “Size” option for better images, or

“Halfx2” for a larger image view. Video quality performance will vary somewhat due to

the number of users viewing on the network; even when the parameters have initially

been finely tuned. Performance will also suffer due to poor connectivity because of

the network’s burst constraint.

Only Quality Images Will Do

To have the best video quality, you should set “Fix quality” at “Detailed” or “Excellent”

and adjust the “Maximum frame rate” to match your network’s bandwidth. If your

network is slow and you receive “broken” pictures, go to the TCP protocol in

“Connection type” and choose a more appropriate mode of transmission. The images

may suffer a time delay due to a slower connection. The delay will also increase with

added number of users.

Somewhere Between Real-time and Clear Images

If you have a broadband network, set “Fix quality” at ”Normal” or better, rather than

setting “Fix bit rate”. You can also fix the bandwidth according to your actual network

speed and adjust the frame rate. Start from 30 fps down for best results but not below

15 fps. If the image qualities are not improved, select a lower bandwidth setting.

Page 37 of the LevelOne Network Camera (WCS-2030) user manual — More flexible options for viewers ○ 4
Page 37 · click to enlarge
Page 37

Opening accounts for new users

LevelOne Network Camera (WCS-2030) — Opening accounts for new users diagram (page 37)
Fig. 34 · Opening accounts for new users

Protect Network Camera by passwords

The Network Camera is shipped without any password by default. That means

everyone can access the Network Camera including the configuration as long as the IP

address is known. It is necessary to assign a password if the Network Camera is

intended to be accessed by others. Type a new word twice in ○ 1 to enable protection.

This password is used to identify the administrator. Then add an account with user

name and password for your friends in ○ 2 . Network Camera can provide twenty

accounts for your valuable customers or friends. Each account identifies the access

right rather than the real visitor. That allows multiple visitors share the same account

of different level. An option to access DI/DO is provided for each account. Some users

may need to prohibit from controlling your attached devices. You may delete some

users from ○ 3 .

More flexible options for viewers ○ 4

The first option allows anyone uses “demo” as the user name to view without password.

The Administrator can also decide if more viewers are allowed to watch the video if the

Page 38 of the LevelOne Network Camera (WCS-2030) user manual — Change homepage layout
Page 38 · click to enlarge
Page 38

viewers exceed the limit. The overloaded viewers will have snapshot mode instead.

Change homepage layout

LevelOne Network Camera (WCS-2030) — Change homepage layout diagram (page 38)
Fig. 35 · Change homepage layout
Page 39 of the LevelOne Network Camera (WCS-2030) user manual — How to change the background
Page 39 · click to enlarge
Page 39

How to change the font color

1. Click on “Configuration” on homepage,
2. Click on “Homepage layout” at the left column,
3. Find “Font color” and pull down the list to choose any color you like,
4. Click on “Save” button.

* The font color is better to contrast with the background.

How to change the background

1. Click on “Configuration” on homepage,
2. Click on “Homepage layout” at the left column,

If you want to display simple color without any image,

3. Find “Background graph” and choose “blank”,
4. Find “Background color” and pull down the list to choose any color you like,
5. Click on “Save” button.

* The background color is better to contrast with the font.

If you want to use the image from another web site as background,

3. Find “Background graph” and choose “Url”,
4. Type the URL of the image on the Internet in the edit box, for example,

“http://dgl.microsoft.com/thumbnails/j023/j0235217(t).gif”,

5. Click on “Save” button.

If you want to change the default background image stored in the Network Camera,

3. Find “Background graph” and choose “default”,
4. Click on “Save” button,
5. Prepare an image file with size less than 131000 bytes and rename it to wallppr.jpg,
6. Open an FTP client program and connect to the Network Camera. The user name and

password is as same as the Administrator’s.

7. Transfer wallppr.jpg in local folder to the Network Camera,
8. Close the FTP program and reload the homepage of the Network Camera.

How to change the image logo at the upper left corner of homepage

1. Click on “Configuration” on homepage,
2. Click on “Homepage layout” at the left column,

If you want to remove any logo,

Page 40 of the LevelOne Network Camera (WCS-2030) user manual — How to change the font color
Page 40 · click to enlarge
Page 40
3. Find “Logo graph” and choose “blank”,
4. Click on “Save” button.

If you want to use the image from another web site as logo,

3. Find “Logo graph” and choose “Url”,
4. Type the URL of the image on the Internet in the edit box, for example,

“http://dgl.microsoft.com/thumbnails/j023/j0234430(t).gif”,

5. Click on “Save” button.

If you want to change the default logo stored in the Network Camera,

3. Find “Logo graph” and choose “default”,
4. Click on “Save” button,
5. Prepare an image file with size less than 65000 bytes and rename it to logo.gif,
6. Open an FTP client program and connect to the Network Camera. The user name and

password is as same as the Administrator’s.

7. Transfer logo.gif in local folder to the Network Camera,
8. Close the FTP program and reload the homepage of the Network Camera.

If you want to add hyperlink to the logo image,

3. Find “Logo link” and type the hyperlink in the edit box, for example,

http://www.mywebsite.com

4. Click on “Save” button.
Page 41 of the LevelOne Network Camera (WCS-2030) user manual — How to design my own homepage to replace the current one
Page 41 · click to enlarge
Page 41

How to design my own homepage to replace the current one

1. Prepare your own homepage with size less than 65000 bytes and rename it to

user.htm,

2. Insert the html codes of video object, the bold Italian text in the following example,

into the appropriate position in user.htm. Note that the codes of video object must be

copied exactly the same including the letter case.

****** Example homepage begin ******

Example – custom homepage

Network Camera. This line is remark only and is hidden on homepage. //-->

****** Example homepage end ******

Show 14 more labels / short text on this page
<html> · <head> · </head> · <p> · align="left" width="64" height="64"> · </a> · Network Camera Demo · </font> · </p> · <p align="left"> · <OBJECT ID=VAMCtrl></OBJECT> · </p> · </body> · </html>
Page 42 of the LevelOne Network Camera (WCS-2030) user manual — How to design my own homepage to replace the current one
Page 42 · click to enlarge
Page 42
3. Open an FTP client program and connect to the Network Camera. The user name and

password is as same as the Administrator’s.

4. Transfer user.htm in local folder to the Network Camera,
5. Close the FTP program and reload the homepage of the Network Camera,
6. Click on “Configuration” on homepage,
7. Click on “Homepage layout” at the left column,
8. Check “Use the customized homepage”.
9. Click on “Save” button and return to homepage.

* The user.htm only provides plain text content that scripts and URL of external

resources can be used to adorn the homepage. Refer to tutorials of writing HTML and

scripts.

If the customized homepage goes wrong and cannot display, link to the “Homepage

layout” page, “http://<IP address of Network Camera>/setup/layout.html”, to disable

“Use the customized homepage”.

Page 43 of the LevelOne Network Camera (WCS-2030) user manual — Product demo for e-business – large-scale service
Page 43 · click to enlarge
Page 43

Build a multimedia web attraction site

Demo on multiple sites – mid-scale service

The Network Camera can allow ten visitors on-line simultaneously. After Installation,

focus the Network Camera on any view you would like friends to share and tell the

visitors to type in the web browser address. Caution: You may want to maintain your

visitor’s list in the security configuration page to block out unexpected visitors. No need

to have the geeks’ skill and equipments, no need to find suitable software.

Product demo for e-business – large-scale service

If the number of visitors has exceeded the limit, the Network Camera can allow the

"overload" viewers to see the snapshots in JPEG mode, on the homepage. These are

still images and will be refreshed periodically and automatically. It needs a script

function supported by the web browser.

LevelOne Network Camera (WCS-2030) — Product demo for e-business – large-scale service diagram (page 43)
Fig. 36 · Product demo for e-business – large-scale service
1. Click on “Configuration” on homepage,
2. Click on “Security” at the left column,
3. Go to the page bottom and check “Allow more viewers with snapshot mode”,
4. Set the snapshot interval to refresh the still image automatically. The longer the

snapshot interval is, the better the snapshot mode works for more viewers.

Page 44 of the LevelOne Network Camera (WCS-2030) user manual — Build a multimedia web attraction site
Page 44 · click to enlarge
Page 44

If you want to expand to allow in more viewers, the host server should be able to

handle large network traffic, which must handle the picture refreshing from the

Network Camera.

If the web space has FTP service,

Set the Network Camera as an FTP client to upload the pictures. The access to the

Network Camera will be independent of the number of viewers and the picture quality

will remain constant.

1. Click on “Configuration” on homepage,
2. Click on “Network” at the left column,
3. Fill the FTP related settings including server, user name and password, as well as the

upload path if specified by the web space,

4. Click on save and wait for system restart,
5. Click on “Application” at the left column,
6. Select “Sequential operation” and set the interval,
7. Select FTP without date time suffix as the upload method and click on save,
8. The image file uploaded to the web space is named “video.jpg”. Check if the file is

successfully uploaded to the correct folder,

9. Prepare a homepage with the embedded image reference to the image file uploaded

via FTP in advance.

If the web space has no FTP service,

An auto-refresh homepage can be used to periodically poll the newest image from the

Network Camera. It is most efficient if using a free web space provider as the FTP

service may be limiting.

1. Prepare an auto-refresh homepage like the following example. The URL of image is

http://“IP address of the Network Camera”/cgi-bin/video.jpg. Modify the IP address

according to your Network Camera. Define the refresh interval according to your

network bandwidth for best result. If the refresh rate is too fast and there is a large

number of visitors, this may overload the Network Camera and slows the response.

Page 45 of the LevelOne Network Camera (WCS-2030) user manual — Build a multimedia web attraction site
Page 45 · click to enlarge
Page 45

****** Example homepage begin ******

Example - auto refresh

URL and refreshrate if necessary. //-->

var image="http://192.168.0.203/cgi-bin/video.jpg" //IMAGE URL

var refreshrate=5; //SECONDS BETWEEN REFRESH

var imgwidth=352; //IMAGE WIDTH

var imgheight=240; //IMAGE HEIGHT (NTSC:240; PAL:288)

document.images["pic"].src=image+"?"+new Date();

document.write('

if(document.images)window.onload=refresh;

****** Example homepage end ******

Show 15 more labels / short text on this page
<html> · <head> · </head> · <p align=left> · Network Camera Demo · </font> · </p> · <p align=left> · <script language=javascript> · function refresh(){ · setTimeout('refresh()', refreshrate*1000);} · width="'+imgwidth+'" name="pic">'); · </script> · </p> · </body>
Page 46 of the LevelOne Network Camera (WCS-2030) user manual — Build a security application
Page 46 · click to enlarge
Page 46

Build a security application

The Administrator can use the built-in motion detection to monitor any movement to

perform many useful security applications. To upload the snapshots, users can choose

either email or FTP according to user’s needs. Both e-mail and FTP use the network

settings on the network page. Refer to the definition section for detail configuration.

1. Click on “ Configuration ” on homepage,
2. Click on “ Motion detection ” at the left column,
3. Check “Enable motion detection”,
4. Click on new to have a new window to monitor video,
5. Type in a name to identify the new window,
6. Use the mouse to click, hold, and drag the window corner to resize or the title bar to
7. Fine-tune using the “Sensitivity” and “Percentage” fields to best suit the camera’s

environment. Higher ”Sensitivity” detects the slighter motion. Higher “Percentage”

8. Clicking on “Save” enables the activity display. Green means the motion in the

window is under the watermark set by Administrator and red means it is over the

9. Click on “ Application ” at the left column,

10.Check the weekdays as you need and give the period of "Snapshots begin" time

and "Snapshots end" time to monitor the motion detection every day,

11.Check the “Send out the snapshot while motion detection”.

12.Set the delay before detecting next motion to avoid continuous false alarms

following the original event,

13.Set the delay to take snapshots after motion to capture the direction of the

14.Check the window name set in step 5,

15.Check the way to upload snapshot,

16.Click on save to validate.

Show 4 more labels / short text on this page
move, · discriminates smaller objects, · watermark, · moving objects,
Page 47 of the LevelOne Network Camera (WCS-2030) user manual — Software revision upgrade
Page 47 · click to enlarge
Page 47

Software revision upgrade

Customers can obtain the up-to-date software from the web site. An easy-to-use

Upgrade Wizard is provided to upgrade the Network Camera with just a few clicks. The

upgrade function is opened to the Administrator only. To upgrade the system, follow

the procedures below.

1. Download the firmware file named “FLASH.BIN” from the appropriate product folder.
2. Run the Upgrade Wizard and proceed following the prompts. Refer to the

instructions of the Upgrade Wizard for details.

3. The whole process will finish in a few minutes and it will automatically restart the

system.

If power fails during the writing process of Flash memory, the program in the

memory of the Network Camera may be destroyed permanently. If the Network

Camera cannot restart properly, ask your dealer for technical service.

Page 48 of the LevelOne Network Camera (WCS-2030) user manual — Definitions in Configuration
Page 48 · click to enlarge
Page 48

Definitions in Configuration

Only the Administrator can access system configuration. Each category in the left

column will be explained in the following pages. The bold texts are the specific phrases

on the Option pages. The Administrator may type the URL below the figure to directly

enter the frame page of configuration. If the Administrator also wants to set certain

options through the URL, read the reference appendix for details.

LevelOne Network Camera (WCS-2030) — Definitions in Configuration diagram (page 48)
Fig. 37 · Definitions in Configuration

http://<Network Camera>/setup/config.html

is the domain name or original IP address of the Network Camera.

Page 49 of the LevelOne Network Camera (WCS-2030) user manual — System parameters
Page 49 · click to enlarge
Page 49

System parameters

"Keep current date and time" Click on this to reserve the current date and time of

the Network Camera. An internal real-time clock maintains the date and time even

when the power of the system is turned off.

"Sync with computer time" Synchronizes the date and time of the Network Camera

with the local computer. The read-only date and time of the PC is displayed as updated.

“Manual” Adjust the date and time according to what is entered by the Administrator.

“Automatic” Synchronize with the NTP server over the Internet whenever the

Network Camera starts up. It will fail if the assigned time-server cannot be reached.

“NTP server” Assign the IP address or domain name of the time-server. Leaving the

text box blank connects the Network Camera to the default time-servers.

"Time zone" Adjust the time with that of the time-servers for local settings.

Remember to click on

to immediately validate the changes. Otherwise, the

correct time will not be synchronized.

Page 50 of the LevelOne Network Camera (WCS-2030) user manual — Security settings
Page 50 · click to enlarge
Page 50

Security settings

“Root password” Change the Administrator’s password by typing in the new

password identically in both text boxes. The typed entries will be displayed as asterisks

for security purposes. After pressing

, the web browser will ask the Administrator

for the new password for access.

“Add user” Type the new user's name and password and press

to insert the new

entry. The new user will be displayed in the user name list. There is a maximum of

twenty user accounts.

“Delete user” Pull down the user list to find the user’s name and press

complete.

“Allow ‘demo’ account to view” Click this to permit anyone who types in “demo” as

user name. No password is needed for demo account. Note that a demo account is

restricted to view only.

“Allow more viewers with snapshot mode” There can only be a maximum of 10

users to simultaneously view the video. This option allows for the 11th viewer on, the

overloaded viewers, to see only still images. These still images are automatically

refreshed by the interval defined below. This feature must be supported by the java

script capability of the web browsers.

“Snapshot interval” defines the refresh rate of the still image in the homepage seen

by the overloaded viewers.

to

Page 51 of the LevelOne Network Camera (WCS-2030) user manual — Streaming
Page 51 · click to enlarge
Page 51

Network settings

Any changes made on this page will restart the system in order to validate the changes.

Make sure every field is entered correctly before clicking on

"Reset IP address at next boot", the default status is checked to get IP address

automatically at the server start. Therefore, once the network settings, especially the

IP address, have been entered correctly, uncheck this option.

General

“IP address” This is necessary for network identification.

“Subnet mask” This is used to determine if the destination is in the same subnet. The

default value is “255.255.255.0”.

“Default router” This is the gateway used to forward frames to destinations in a

different subnet. Invalid router setting will fail the transmission to destinations in

different subnet.

“Primary DNS” The primary domain name server that translates hostnames into IP

addresses.

“Secondary DNS” Secondary domain name server that backups the Primary DNS.

HTTP

“Http port” This can be other than the default Port 80. Once the port is changed, the

users must be notified the change for the connection to be successful. For instance,

when the Administrator changes the HTTP port of the Network Camera whose IP

address is 192.168.0.100 from 80 to 8080, the users must type in the web browser

“http://192.168.0.100:8080” instead of “http://192.168.0.100”

Streaming

“Control channel port” This can be something other than the default port 5001 in

order to work with the port opened by the firewall.

“Audio channel port” This can be something other than the default port 5002 in

order to work with the port opened by the firewall.

“Video channel port” This can be something other than the default port 5003 in

order to work with the port opened by the firewall.

Page 52 of the LevelOne Network Camera (WCS-2030) user manual — WLAN Configuration
Page 52 · click to enlarge
Page 52

“Improve audio quality in low bandwidth environment” If the Network Camera

seems to work in a low bandwidth network environment, the user can use this option

to see if audio quality can be improved by sacrificing some real-time synchronization.

“Mute” This can force the transmission protocol to HTTP and disable audio.

WLAN Configuration

“SSID” (Service Set Identifier), it is a name that identifies a wireless network. Access

Points and wireless clients attempting to connect to a specific WLAN (Wireless Local

Area Network) must use the same SSID. The default setting is default. Note: The

maximum length of SSID is 32 single-byte characters and SSID can’t be any of “, <, >

and space character.

“Wireless mode” Clicking on the pull-down menu to select from the following

options:

“Infrastructure” Make the Network Camera connect to the WLAN via an Access Point.

“Ad-Hoc” Make the Network Camera connect directly to a host equipped with a

wireless adapter in a peer-to-peer environment.

“Channel” While in infrastructure mode, the channel is selected automatically to

match the channel setting for the selected Access Point. In Ad-Hoc mode, the channel

must be manually set to the same channel for each wireless adapter. The default

channel setting depends on the installed region.

“TX rate” This field is for selecting the maximum transmission rate on the network.

The default setting is “auto”, that is the Network Camera will try to connect to the other

wireless device with highest transmitting rate.

“Preamble”, either “Long preamble” or “Short preamble” defines the length of the

CRC block (Cyclic Redundancy Check is a common technique for detecting data

transmission errors) for communication between the Access Point and the roaming

wireless device. Long Preamble is the default setting. Note: High network traffic areas

should use the shorter preamble type.

“Data encryption” Checking the box to enable the data encryption. By default it is

disabled.

“Auth. Mode” Choosing one of the following modes, (Auto is the default setting)

z “Auto” – Will automatically decide the authentication mode of the wireless client.

z “Shared” – allows communication only with other devices with identical WEP

settings.

z “Open” – communicates the key across the network.

(The default setting)

Page 53 of the LevelOne Network Camera (WCS-2030) user manual — SMTP
Page 53 · click to enlarge
Page 53

“Key length” The administrator can select the key length among 64, 128 or 256 bits.

64bits is the default setting.

“Key format” Hexadecimal or ASCII. “HEX” is the default setting.

z “HEX” digits consist of the numbers 0~9 and the letters A-F.

z “ASCII” is a code for representing English letters as numbers from 0-127 except

“, and space characters that are reserved.

“Network Key” Entering a key in either hexadecimal or ASCII format. When selecting

different key length, acceptable input length is listed as following:

64 bits key length: 10 Hex digits or 5 characters.

128 bites key length: 26 Hex digits or 13 characters.

256 bits key length: 58 Hex digits or 29 characters.

changed to ASCII format.

Some invalid settings may cause the system failing to respond. Change the

configuration only if necessary and consult with your network supervisor or experienced

users for correct settings. Once the system has lost contact, refer to Appendix A for reset

and restore procedures.

Mail & FTP

SMTP

When the SMTP server support SMTP authentication, users need to give the valid user

name and password to send email via the server.

“SMTP (mail) server 1” The domain name or IP address of the external email server.

“User name of SMTP 1” This granted user name on the external email server.

“Password of SMTP 1” This granted password on the external email server.

“Recipient email address 1” The email address of the recipients for snapshots or log

file. Multiple recipients must be separated by semicolon, ‘;’.

“SMTP (mail) server 2” The domain name or IP address of another email server once

the previous server is unreachable.

“User name of SMTP 2”, granted user name on the backup email server.

Page 54 of the LevelOne Network Camera (WCS-2030) user manual — FTP
Page 54 · click to enlarge
Page 54

“Password of SMTP 2”, granted password on the backup email server.

“Recipient email address 2” The email address of the recipients for the backup

server.

“Sender email address”, the email address of the sender.

FTP

“Local FTP server port” This can be other than the default port 21. The user can

change this value from 1 to 65535. After the changed, the external FTP client program

must change the server port of connection accordingly.

“1st FTP server” The domain name or the IP address of the external FTP server. The

following user settings must be correctly configured for remote access.

“1st FTP user name” Granted user name on the external FTP server.

“1st FTP password” Granted password on the external FTP server.

“1st FTP remote folder” Granted folder on the external FTP server. The string must

conform to that of the external FTP server. Some FTP servers cannot accept preceding

slash symbol before the path without virtual path mapping. Refer to the instructions for

the external FTP server for details. The folder privilege must be open for upload.

“Primary FTP passive mode” The Network Camera is located inside the network

protected by a firewall, data connection for FTP may be prohibited. By selecting passive

mode, the FTP can bypass the rule and allow snapshot upload to proceed. If the passive

mode is selected, the Network Camera can automatically attempt for active mode, if

the external FTP server does not support passive mode.

“2nd FTP server” The domain name or IP address of the external FTP server.

“2nd FTP user name” Granted user name on the backup FTP server.

“2nd FTP password” Granted password on the backup FTP server.

“2nd FTP remote folder” Granted folder on the backup FTP server.

“Secondary FTP passive mode” Passive mode setting for the backup FTP server.

Page 55 of the LevelOne Network Camera (WCS-2030) user manual — Video codec parameters
Page 55 · click to enlarge
Page 55

DDNS and UPnP settings

“Enable DDNS” This option turns on the DDNS function.

“Provider” The provider list contains four hosts that provide DDNS services. Please

connect to the service provider’s website to make sure the service charges.

“Host name” If users wants to use DDNS service, this field must be filled. Please input

the hostname that is registered in the DDNS server.

“Username/E-mail” The Username or E-mail field is necessary for logging in the

DDNS server or notify users of the new IP address. Note: when this field is input as

“Username” the following field must be input as “Password”.

“Password/Key” Please input the password or key to get the DDNS service.

“Enable UPnP” This turns on or off the UPnP function. When UPnP is turned off, the

camera cannot be found through network neighbors in MS Windows XP. If the UPnP

network component is installed in Windows XP, the hostname of the Network Camera

will be shown with bracketed IP address in the Network neighbors. Ex: Network

Camera (192.168.0.96). That isThe hostname of the Network Camera is “ Network

Camera”, and the IP address of the Network Camera is 192.168.0.96.

“Save” Click on the button to save current settings for the DDNS service and UPnP

function.

Network Camera provides a free DDNS service. Administrators can choose safe100.net

in the “Providers” field to use it. At the first time, Administrators must register an

account for it.

Video codec parameters

“Text on video” The text will be displayed in the black bar above the video window

with a timestamp. The timestamp is captured from the date and time of the Network

Camera that is maintained by a built-in real-time clock.

“Color” Select either for color or monochrome video display.

“Size” There are five options for three video sizes. “Half” is the quarter size of

“Normal”. “Half x 2” has the same video size as “Normal” but of a lesser quality,

while consuming less network bandwidth. “Normal” is the quarter size of “Double”.

“Normal x 2” has the same video size as “Double” but of a lesser quality, while

consuming less network bandwidth.

“Power line frequency (for fluorescent light)”, the fluorescent light will flash

according to the power line frequency that depends on local utility. Change the

frequency setting to eliminate uncomfortable flash image when the light source is only

Page 56 of the LevelOne Network Camera (WCS-2030) user manual — DDNS and UPnP settings
Page 56 · click to enlarge
Page 56

fluorescent light.

There are three dependent parameters provided for video performance adjustment.

“Maximum frame rate” This limits the maximal refresh frame rate, which can be

combined with the “Video quality control” to optimize bandwidth utilization and

video quality. If the user wants to fix the bandwidth utilization regardless of the video

quality, choose “Fix bit rate” and select the desired bandwidth. The video quality may

be poor due to the sending of maximal frame rate within the limited bandwidth when

images are moving rapidly. Consequently, to ensure detailed video quality

(quantization rate) regardless of the network, it will utilize more bandwidth to send the

maximal frames when images change drastically.

“Flip” Vertically rotate the video.

“Mirror” Horizontally rotate the video. Check options both if the Network Camera is

installed upside down.

“White balance” Adjust the value for best color temperature.

Click on this button to pop up another window to tune “Brightness”,

“Contrast”, “Hue” and “Saturation” for video compensation. Each field has eleven

levels ranged from -5 to +5. In “Brightness” and “Contrast” fields the value 0

indicates auto tuning. The user may press

to fine-tune the image. When the

image is O.K., press

to set the image settings.

Click on this to recall the

original settings without incorporating the changes.

Page 57 of the LevelOne Network Camera (WCS-2030) user manual — Motion detection
Page 57 · click to enlarge
Page 57

Motion detection

“Enable motion detection” Check this option to turn on motion detection.

Click on this button to add a new window. At most three windows can exist

simultaneously. Use the mouse to click, hold, and drag the window frame to resize or

the title bar to move. Clicking on the ‘x’ at the upper right-hand corner of the window

to delete the window. Remember to save in order to validate the changes.

Click on this button to save the related window settings. A graphic bar will rise or

fall depending on the image variation. A green bar means the image variation is under

monitoring level and a red bar means the image variation is over monitoring level.

When the bar goes red, the detected window will also be outlined in red. Going back to

the homepage, the monitored window is hidden but the red frame shows when motion

is detected.

"Window Name" The text will show at the top of the window.

“Sensitivity” This sets the endurable difference between two sequential images.

“Percentage” This sets the space ratio of moving objects in the monitoring window.

Higher sensitivity and small percentage will allow easier motion detection.

The following figure shows the screen when

is clicked. The monitoring window

has been outlined in red and the graphic bar goes red since the goldfish is moving.

LevelOne Network Camera (WCS-2030) — Motion detection diagram (page 57)
Fig. 38 · Motion detection
Page 58 of the LevelOne Network Camera (WCS-2030) user manual — Sequential operation
Page 58 · click to enlarge
Page 58

Application settings

Weekly schedule

“Sun” ~ “Sat” Select the days of the week to perform the following operations.

“Snapshots begin at” Set the time to start operations.

“Snapshots stop at” Set the time to stop operations.

Setting identical begin time and stop time means 24-hour operation.

“All the time except for the above schedule” Set the schedule all the time except

for the above in a week.

Send out the snapshot while motion detection

“Delay second(s) before detecting next motion” Set the time delay before

restarting to check on the triggering condition when the current condition is triggered.

“Take snapshots at second(s) after motion” After the camera has taken a

snapshot when a condition is triggered, another snapshot will be taken after this

configured interval, in seconds.

“Trigger condition” There are three windows for motion detection each can be

assigned a name. If motion detection has not been set up, “undefined” will be shown

instead of the window title. If this happens, clicking on “Motion detection” and a note

will show to direct the User to the configuration page for motion detection.

Sequential operation

“Snapshot every second(s)” The Network Camera will send snapshots at the

specified intervals to the external server using the method selected below. Remember:

This operation is still subject to the conditions set in the weekly schedule.

“Send snapshots by email” This selects the uploading method following the

intervals set above. The snapshot named “video.jpg” will be attached in the email with

the subject title “Periodic snapshots”.

“Send snapshots by FTP” The snapshots will be uploaded to the external FTP server

with the file name defined in the next option. This can also be used to refresh the

captured images stored in the external web server to build creative homepages.

“FTP put snapshots with date and time suffix” This option sets up the snapshot

capture date and time, which can be used to easily differentiate the snapshot file

Page 59 of the LevelOne Network Camera (WCS-2030) user manual — Application settings
Page 59 · click to enlarge
Page 59

names in either the sequential or event operation. For instance,

“[email protected]” means the JPEG image was captured in the year 2003,

January the 2nd, at 3 o’clock, 4 minute, and 5 second. If this suffix is omitted, the file

named “video.jpg” on the external FTP server will be refreshed at the specified interval.

Page 60 of the LevelOne Network Camera (WCS-2030) user manual — Homepage layout settings
Page 60 · click to enlarge
Page 60

Homepage layout settings

“Use the customized homepage”, check this option to use “user.htm” uploaded by

the Administrator instead of the default one. Refer to the section “Administrator’s

capability” for detail usage. The following options related to the default homepage will

not affect the “user.htm”.

“Logo graph”, the logo located at the upper left corner of homepage can be hidden,

the default one that can be changed by the Administrator, or any image on the Internet

that can be located via URL. The default logo is stored in memory and can be changed

by FTP. The maximal size is 32000 bytes. Though the file name is fixed to “logo.gif”, the

image can be any file format as long as the web browser can read it. Refer to the

section “Administrator’s capability” for how to change the default logo.

“Logo link”, when users click on the logo image, a new window will pop up to show

the homepage of the given URL. Clear the URL will disable the link function.

“Background graph”, the background image can be hidden to show the background

color only, the default one that can be changed by the Administrator, or any image on

the Internet that can be located via URL. The default background image is stored in

memory and can be changed by FTP. The maximal size is 131000 bytes. Though the file

name is fixed to “wallppr.jpg”, it can be any file format as long as the web browser can

read it. Refer to the section “Administrator’s capability” for how to change the

background image.

”Font color", pull down the list to select any color for the text in the homepage.

”Background color", pull down the list to select any color for the homepage

background. It can be seen when the background image is not displayed.

Page 61 of the LevelOne Network Camera (WCS-2030) user manual — Factory default
Page 61 · click to enlarge
Page 61

Viewing system log

Click the link on the configuration page to view the system log file. The content of the

file provides useful information about configuration and connection after system boot-

up.

Viewing system parameters

Click on this link on the configuration page to view the entire system’s parameter set.

The content is the same as those in CONFIG.INI.

Factory default

Click on this link on the configuration page to restore the factory default settings. Any

changes made so far will be lost and the system will be reset to the initial factory

settings. After clicking on the “OK” button and make confirmation, the system will

restart and require the installer program to set up the network again.

Page 62 of the LevelOne Network Camera (WCS-2030) user manual — B. Frequently asked questions
Page 62 · click to enlarge
Page 62

Appendix

A. Troubleshooting

Status LED

After powering up, the Network Camera performs a self-diagnostic to detect any

hardware defects. The following table lists the LED patterns in general. In case of any

fatal error, the LED will blink in a pattern other than those below.

During self-diagnostic after power on Blink in interchanged green and red

Ethernet signal is lost Steady red till Ethernet is detected

Before network is setup Steady green till IP address is confirmed

After network is setup Blink green every second

Network is setup and audio is disabled Blink green every 4 seconds

Any hardware failure Other patterns

Reset and restore

button in the back of the Network Camera. It is used to reset the

LevelOne Network Camera (WCS-2030) — Reset and restore diagram (page 62)
Fig. 39 · Reset and restore

system or restore the factory default settings. Sometimes

resetting the system sets the system back to normal state. If the

system problems remain after reset, restore the factory settings

and install again.

RESET: Click on the button.

RESTORE: 1. Press on the button continuously.

2. Wait for self-diagnostic to run twice.
3. Free the button as soon as the second self-diagnostic starts.

Restoring the factory defaults will erase any previous settings. Reset or restore the

system after power on.

B. Frequently asked questions

Q What if I forget my password?

A After the Administrator's password is assigned, every access to the Network Camera

Condition LED color · There is a

Page 63 of the LevelOne Network Camera (WCS-2030) user manual — Appendix
Page 63 · click to enlarge
Page 63

needs authentication. If you are one of the managed users, you have to ask the

Administrator for the password. If you are the Administrator, there is no way to recover

the root password except for restoring factory default. Refer to Appendix A for the

procedures.

Q Why can I not watch video from the Network Camera after it is authenticated?

A There are many possible scenarios regarding this problem,

1. If you have just installed the Network Camera and are unable to watch the video,

check if the heartbeat LED is blinking or the lens cap is removed. If the heartbeat LED

is dim, perform the software installation again.

2. If the Network Camera is well installed and you are accessing the Network Camera

for the first time using Internet Explorer, adjust the security level of Internet Explorer

to allow installation of plug-ins.

3. If the problem still exists after adjusting, and the message over the image window

is showing "connecting", the network traffic may be too crowded.

Q What is the plug-in for?

A The plug-in provided by the Network Camera is used to display motion pictures and

audio in Internet Explorer. If your system does not allow installation of any plug-in

software, the security level of the web browser may need to be lowered. It is

recommended that you consult your network supervisors in your office regarding

adjustment of the security level. Software installation may be regulated in some

offices.

Q Why is the timestamp different from the system time of my PC or notebook?

A The timestamp is based on the system time of the Network Camera. It is maintained

by a real-time clock inside and can be automatically synchronized with the time server

if the Network Camera is connected to the Internet and the function is enabled.

Differences of several hours may result from the time zone setting.

Q Can I install it on ceiling?

A Yes. There are flip and mirror options in video configuration page to correct the

images for upside down installation.

Q The image is not clear enough.

A Rotate the lens to adjust the focus after the Network Camera is installed in the proper

position. The image settings and white balance can be fine tuned to achieve the best

visual effect. Also notice the power line frequency must match the local utility to

synchronize and minimize the effect of flickering florescent lights.

Page 64 of the LevelOne Network Camera (WCS-2030) user manual — Appendix
Page 64 · click to enlarge
Page 64

Q Why does the image not refresh regularly?

A Some anti-virus programs filter the received web content. It takes time to perform

data examination and affect the streaming application such as the Network Camera.

However it only affects the HTP mode of the Network Camera. If the network allows

only HTTP mode, disable the web filtering function of the anti-virus program

temporarily. During the period, users should be aware of the risk of malicious network

activity.

Q I have opened motion detection windows but it cannot work.

A If the motion detection windows are setup and names are given, check to see if the

function is checked at the first line. While it is enabled, adjust the sensitivity and

percentage to monitor the level indicator for best results.

Q I cannot hear any sound while watching.

A If there is "V_ONLY" shown above the image, click on connection type to uncheck

"Disable audio". If there is "V" shown instead of "AV", the sound card in your PC may

not properly installed. If "AV" is shown, check the audio source of the Network Camera.

Q How many users are allowed to watch the Network Camera at the same time?

A Too many users requesting the real-time multimedia content will jam the network.

For best results, the Network Camera is designed to accommodate maximum ten (10)

users to watch and listen to the Network Camera at the same time. For a larger number

of users, it is recommended to build another web server to host the retrieving contents

from the Network Camera.

Q How fast is the video rate of the Network Camera?

A The MPEG4 codec engine can process 30 frames per second internally. However the

total performance is subject to many coefficients as follows:

1. Network throughput,
2. Bandwidth share,
3. Number of users,
4. The complicated/detailed objects and movement in view,
5. The level of your PC or notebook computer that is responsible for displaying images.

In general, the transfer rate in a general local network environment can achieve over

200 kilobytes per second and approximately 10 to 20 pictures per second from a

regular environment.

Page 65 of the LevelOne Network Camera (WCS-2030) user manual — Appendix
Page 65 · click to enlarge
Page 65

Q How can I keep the Network Camera as private as possible?

A The Network Camera is designed for surveillance purposes and has many flexible

interfaces. The user authentication and special confirmation in installation can keep the

Network Camera from unauthorized access. You may also change the HTTP port to

non-public number. The demo account is good to separate guests from normal users

and thus you can easily block guests anytime. You can check the system log to examine

any abnormal activities and trace the origins.

Q Why can I not access the Network Camera when I setup some options in the

A Since the Network Camera is a "network device", any incorrect network settings will

make it unreachable. If this happens, restore the factory default settings following the

procedures in Appendix A.

application?

Page 66 of the LevelOne Network Camera (WCS-2030) user manual — Restore factory default settings
Page 66 · click to enlarge
Page 66

C. URL commands of the Network Camera

For some customers who already have their own web site or web control application,

the Network Camera can be easily integrated through convenient URLs. This section

lists the commands in URL format corresponding to the basic functions of the erase

Network Camera.

Capture update Snapshot of JPEG image

/cgi-bin/video.jpg?size=

The Network Camera will return the most up-to-date snapshot in JPEG format. The

value of size can be 1, 2 and 3. 1 means half, 2 means normal and 3 means double. If

users do not set the size in this command, the snapshot size will be the same as the

setting of video option.

Query status of the digital input

/cgi-bin/getdi.cgi

The Network Camera will return the status of digital input.

Drive the digital output

/cgi-bin/setdo.cgi?do=

The state is either “H”, or “L”.”H” means high, that is NC is connected with COMMON and

“L” means low that is NO is connected with COMMON.

For instance, typing http://192.168.0.201/cgi-bin/setdo.cgi?do=h in the address bar

of the web browser will command the Network Camera, with IP address of

192.168.0.201, to set digital output to connect to NC with COMMON.

Restore factory default settings

/setup/restore.cgi

The Network Camera will automatically restart after restoring factory default

configurations.

Page 67 of the LevelOne Network Camera (WCS-2030) user manual — Restart system
Page 67 · click to enlarge
Page 67

Restart system

/setup/reset.cgi

Restart the Network Camera without warning.

Page 68 of the LevelOne Network Camera (WCS-2030) user manual — System resource URL
Page 68 · click to enlarge
Page 68

Page URL

The configuration page has a frame layout including an option list frame and an option

page frame. Referenced URLs, except for the configuration page, direct users to the

option page frame only. Some pages, such as image quality setting and preset setting,

are opened in new windows for preview.

Only the Administrator can access these URLs.

Homepage name Referenced URL

connection type page /client.html

configuration page /setup/config.html

system option /setup/system.html

security option /setup/security.html

network option /setup/network.html

DDNS and UPnP option /setup/ddns.html

mail and FTP option /setup/mailftp.html

video option /setup/video.html

motion detection /setup/motion.html

image quality option /setup/image.html

application option /setup/app.html

homepage layout option /setup/layout.html

system log /setup/logfile.html

system parameters /setup/parafile.html

set factory default /setup/factory.html

System resource URL

There are some images used on the homepage when the homepage layout is in image

mode. The Administrator may use the following links to show the images saved in the

Network Camera on another page.

Resource name Referenced URL

system logo image /pic/logo.gif

background image /pic/wallppr.jpg

Page 69 of the LevelOne Network Camera (WCS-2030) user manual — NAME VALUE DESCRIPTION
Page 69 · click to enlarge
Page 69

General format of command URL

Every configuration can be set through URL with POST method by the Administrator

only.

POST

System configuration URL

URL/setup/system.cgi

NAME VALUE DESCRIPTION

host

keep keep date and time unchanged

auto use NTP server to synchronize

manu directly adjust date and time

date year, month and date separated by

time hour, minute and second separated

ntp NTP server

zone -12 ~ 12 time zone, 8 means GMT +8:00

Show 10 more labels / short text on this page
<general format> · URL[?[name=value][&name=value]……] · <method> · <authorized user> · root · system name · characters> · method · slash · by colon
Page 70 of the LevelOne Network Camera (WCS-2030) user manual — Network configuration URL
Page 70 · click to enlarge
Page 70

Security configuration URL

URL/setup/security.cgi
LevelOne Network Camera (WCS-2030) — Security configuration URL diagram (page 70)
Fig. 40 · Security configuration URL

Network configuration URL

URL/setup/network.cgi
LevelOne Network Camera (WCS-2030) — Network configuration URL diagram (page 70)
Fig. 41 · Network configuration URL
Page 71 of the LevelOne Network Camera (WCS-2030) user manual — C. URL commands of the Network Camera
Page 71 · click to enlarge
Page 71
LevelOne Network Camera (WCS-2030) — C. URL commands of the Network Camera diagram (page 71)
Fig. 42 · C. URL commands of the Network Camera
Page 72 of the LevelOne Network Camera (WCS-2030) user manual — NAME VALUE DESCRIPTION
Page 72 · click to enlarge
Page 72

DDNS & UPnP configuration URL

URL/setup/ddns.html

NAME VALUE DESCRIPTION

enddns anything Enable DDNS function. This option

must be resent whenever the URL is

called, if DDNS function is to be

enabled.

1 DynDNS.org(Dynamic)

2 DynDNS.org(Custom)

3 TZO.com

4 dhs.org

host

The hostname of the Network

usermail

The login username of DDNS server

or the email address registered in

DDNS server.

passkey

The login password of DDNS server

or the key given by the DDNS server.

enupnp anything Enable UPnP function. This option

must be resent whenever the URL is

called, if UPnP function is to be

enabled.

Mail & FTP configuration URL

URL/setup/mailftp.html

NAME VALUE DESCRIPTION

smtp1 primary SMTP server

smtp1Usr

user name for primary SMTP server

smtp1pass

password for primary SMTP server

mail1

smtp2 secondary SMTP server

Show 9 more labels / short text on this page
provider · characters> · Camera · characters> · characters> · characters> · characters> · mail recipient address · characters>
Page 73 of the LevelOne Network Camera (WCS-2030) user manual — Video configuration URL
Page 73 · click to enlarge
Page 73
LevelOne Network Camera (WCS-2030) — C. URL commands of the Network Camera diagram (page 73)
Fig. 43 · C. URL commands of the Network Camera

ftp1 primary FTP server

ftp2 secondary FTP server

Video configuration URL

URL/setup/video.cgi
LevelOne Network Camera (WCS-2030) — Video configuration URL diagram (page 73)
Fig. 44 · Video configuration URL
Page 74 of the LevelOne Network Camera (WCS-2030) user manual — C. URL commands of the Network Camera
Page 74 · click to enlarge
Page 74
LevelOne Network Camera (WCS-2030) — C. URL commands of the Network Camera diagram (page 74)
Fig. 45 · C. URL commands of the Network Camera
Page 75 of the LevelOne Network Camera (WCS-2030) user manual — Application configuration URL
Page 75 · click to enlarge
Page 75

Image quality configuration URL

URL/setup/image.cgi
LevelOne Network Camera (WCS-2030) — Image quality configuration URL diagram (page 75)
Fig. 46 · Image quality configuration URL

Application configuration URL

URL/setup/app.cgi
LevelOne Network Camera (WCS-2030) — Application configuration URL diagram (page 75)
Fig. 47 · Application configuration URL

suffix FTP file with date and time suffix

motion1 < not required > set motion window1 as trigger

motion2 < not required > set motion window2 as trigger

motion3 < not required > set motion window3 as trigger

5 fixed outdoor(6000K)

Page 76 of the LevelOne Network Camera (WCS-2030) user manual — NAME VALUE DESCRIPTION
Page 76 · click to enlarge
Page 76

Homepage layout configuration URL

URL/setup/layout.cgi

NAME VALUE DESCRIPTION

def use default logo

url use image from URL

logourl

URL of image for logo

linkurl

URL to link when clicking on logo

blank hide background image

def use default background

url use image from URL

backurl

URL of image for background

fcolor color index for font

bcolor color index for background

Show 6 more labels / short text on this page
cuslogo · blank hide logo · characters> · characters> · cusback · characters>
Page 77 of the LevelOne Network Camera (WCS-2030) user manual — D. Technical specifications
Page 77 · click to enlarge
Page 77

D. Technical specifications

- System CPU: Trimedia PNX1300 RAM: 16MB SDRAM ROM: 2MB FLASH ROM - Networking Protocol TCP/IP, HTTP, SMTP, FTP, DDNS, UPnP , Telnet, NTP, DNS and DHCP Physical 10 baseT or 100 baseT Fast Ethernet auto negotiation - Video Algorithm supported MPEG4(short header mode) for streaming video JPEG for still image Features Adjustable image size, quality and bit rate Time stamp and text overlay 3 motion detection windows Resolution Up to 30/25 frames at 160x120 Up to 30/25 frames at 320x240 Up to 10 frames at 640x480 - Camera Specification 1/4 inch color CMOS sensor Resolution: 640x480 AGC, AWB, AES Electronic shutter: 1/60 ~ 1/15000 second - Lens Fixed focal with fine tuning, 4.0mm, F2.0

Frequency: 50 – 16000Hz S/N ratio: more than 60dB - LED indicator Dual color status indicator - Dimension 28.6mm(D) * 72.8mm(W) * 115.2mm(H) - Weight NET. 245g - Power Input: 100-240VAC, 50/60Hz, 0.4A Output: 5VDC, 2A - Operating Environment Temperature: 0-50°C/32-122°F Humidity: 95%RH - EMI & Safety CE, FCC - Viewing system requirement Operating system Microsoft Windows 98SE/ME/2000/XP Browser Internet Explorer 5.x or above

- Audio Bite rate24Kbps Supporting audio mute - Microphone Omni-directional
Page 78 of the LevelOne Network Camera (WCS-2030) user manual — C. URL commands of the Network Camera
Page 78 · click to enlarge
Page 78
Page 78 of the LevelOne Network Camera (WCS-2030) user manual — C. URL commands of the Network Camera
Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the LevelOne Network Camera (WCS-2030)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the LevelOne Network Camera (WCS-2030)

Be the first to ask — other owners or our team will answer.

Original document

LevelOne Network Camera (WCS-2030) manual PDF

78 pages·3.4 MB·Network Camera·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…