OVERVIEW

MANUALLY SET CLOCK

1. Press and hold MODE . 2. Press or to change the settings. (Press and hold to change the setting quickly.) 3. Press MODE to confirm. 4. The settings order is: time zone offset, hour, minute, year, month, day and language.

FRONT VIEW (FIG. 1)

1. SNOOZE : Snooze alarm 2. Weather forecast and pressure trend 3. Outdoor temperature readings and trends, and Hi / Lo temperature alarms 4. Atomic clock / alarm and date 5. Indoor temperature readings and trends 6. MODE : Change settings or display 7. ALARM : View alarm status; set alarm 8. MEM : View current, maximum and minimum temperature

0FHF4 Weather Finder

USER MANUAL

(FIG. 1)

To select display modePress MODE to choose between clock with seconds and clock with weekday. ALARM

BACK VIEW (FIG. 2)

L.L. Bean Weather Station (0FHF4) — BACK VIEW (FIG. 2) diagram (page 1)
Fig. 1
1. Wall mount hole 2. RESET : Reset unit to default settings 3. CH : Switch remote sensor display 4. TEMP HI / LO : Change settings or enable / disable Hi or Lo temperature alarm 5. °C / °F : Select temperature unit 6. / : Increase / decrease setting; activate / deactivate clock reception signal 7. Battery compartment 8. Table stand

To set the alarm: 1. Press ALARM to view display. shows when the alarm time is displayed. 2. Press and hold ALARM. 3. Press / to set hour / minute. (Press and hold to change the setting quickly.) 4. Press ALARM to confirm. indicates alarm is ON.

REMOTE SENSOR (FIG. 3)

To toggle alarms ON / OFF: 1. Press ALARM to display alarm time. 2. Press ALARM again to turn alarm ON / OFF.

L.L. Bean Weather Station (0FHF4) — REMOTE SENSOR (FIG. 3) diagram (page 1)
Fig. 2
1. LED status indicator 2. Wall mount hole 3. Battery compartment 4. RESET hole 5. CHANNEL switch
  • To silence the alarm:
  • Press SNOOZE to silence it for 8 minutes. OR
  • Press any other key to turn the alarm off and activate it again after 24 hours.

GETTING STARTED

INSERT BATTERIES

WEATHER FORECAST

1. Remove the battery door. 2. Insert the batteries, matching the polarities (see FIG. 2). 3. Press RESET after each battery change.
SunnyPartially CloudyCloudyRainy

(FIG. 2)

LOCATION MEANING

Indoor temperature area Main unit batteries low

L.L. Bean Weather Station (0FHF4) — (FIG. 2) diagram (page 1)
Fig. 3

Outdoor temperature area Sensor batteries low

TEMPERATURE

REMOTE SENSOR

To toggle temperature unit: Slide °C / °F to the desired setting.

The main unit can collect data from up to 3 sensors.

To set up the sensor: 1. Slide open the battery door. 2. Insert the batteries, matching the polarities. 3. Select a channel, then press RESET (Reset after a channel or battery change.) 4. Close the battery door. 5. Place the sensor within 30 m (98 ft) of the main unit using the table stand or wall mount (see FIG. 4). NOTE Use alkaline batteries for longer usage and consumer grade lithium batteries in temperatures below freezing.

To view outdoor sensors readings: Press CH.

To auto-scan between sensors: Press and hold CH to display each sensor’s data for 3 seconds.

To end press CH or MEM.

To toggle between current, minimum and maximum records for the selected outdoor sensor and indoor (main unit) sensor: Press MEM repeatedly.

To clear the records: Press and hold MEM.

WEATHER TRENDS

SENSOR DATA TRANSMISSION

The pressure trend icons are based on recent sensor readings.

To search for a sensor: Simultaneously, press and hold MEM and CH for 2 seconds.

RISE STEADY FALL

(FIG. 3)

L.L. Bean Weather Station (0FHF4) — RISE STEADY FALL diagram (page 1)
Fig. 4
L.L. Bean Weather Station (0FHF4) — RISE STEADY FALL diagram (page 1)
Fig. 5
DESCRIPTION Main unit is searching for sensor(s A channel has been found Sensor 1 data received nd “--.-“The sensor cannot be found

HI / LO TEMP ALARMS

Temperature alerts can be set to sound if sensor set to Channel 1 records above or below a temperature of your choice.

To set alarm ON / OFF: 1. Press and hold TEMP HI / LO . 2. Use or to change settings. 3. Press TEMP HI / LO to confirm. 4. The setting order is: alarm type, alarm ON / OFF, alarm temperature value. LO /

CLOCK

will appear above the temperature to indicate the alarm is on.

HI

(FIG. 4)

CLOCK RECEPTION

To silence the Hi / Lo alarm: Press any key. The alarm resets automatically and will resound if the hi / lo temperature selected is recorded again.

This product is designed to synchronize its clock auto- matically with a clock signal. • WWVB-60 signal: within 3200 km (2000 miles) of Fort Collins, Colorado. Manually set clock to select time zone (Pacific, Mountain, Central or Eastern).

RESET

To enable / disable signal reception: Press and hold to enable or to disable signal reception.

Press RESET to return to the default settings.

PRECAUTIONS

  • Do not subject the unit to excessive force, shock, dust, temperature or humidity
  • Do not cover the ventilation holes with any items such s newspapers, curtains etc.
  • Do not immerse the unit in water. If you spill liquid over it, dry it immediately with a soft, lint-free cloth.
  • Do not clean the unit with abrasive or corrosive materials.
  • Do not tamper with the unit’s internal components. This invalidates the warranty.

STRONG SIGNAL WEAK SIGNAL NO SIGNAL

BAR186A_IM_LLB_EN_NO R_R0 20.11.2007, 10:23 AM 1

Show 19 more labels / short text on this page
· · · · · · · · · · · · · · · · · ·
Page 2 of the L.L. Bean Weather Station (0FHF4) user manual — 086L004860-029
Page 2 · click to enlarge
Page 2
  • Only use fresh batteries. Do not mix new and old batteries.
  • Images shown in this manual may differ from the actual display.
  • When disposing of this product, ensure it is collected separately for special treatment.
  • Placement of this product on certain types of wood may result in damage to its finish for which Oregon Scientific will not be responsible. Consult the furniture manufacturer’s care instructions for information.
  • The contents of this manual may not be reproduced without the permission of the manufacturer.
  • Do not dispose old batteries as unsorted municipal waste. Collection of such waste separately for special treatment is necessary.
  • Please note that some units are equipped with a battery safety strip. Remove the strip from the battery compartment before first use.

SPECIFICATIONS

L x W x H160 x 84 x 38 mm (6.3 x 3.3 x 1.5 in) Weight195 g (6.88 oz) without battery Temperature range-5°C to 50°C (23°F to 122°F) Resolution0.1°C (0.2°F) Signal frequency433 MHz Batteries4 x UM-3 (AA) 1.5 V
L x W x H96 x 50 x 22 mm (3.8 x 2.0 x 0.9 in) Weight62 g (2.22 oz) Transmission range30 m (98 ft) unobstructed No. of channels3 Temperature range-30°C to 60°C (-22°F to 140°F) Batteries1 x UM-3 (AA) 1.5 V

FCC STATEMENT

This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation.

  • This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:
  • Reorient or relocate the receiving antenna.
  • Increase the separation between the equipment and receiver.
  • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
  • Consult the dealer or an experienced radio / TV technician for help.

DECLARATION OF CONFORMITY

The following information is not to be used as contact for support or sales. Please call our customer service number (listed on our website at, www.llbean.com or on the warranty card for this product) for all inquiries instead.

We Name: L.L. Bean, Inc. Address: Freeport, Maine 04033-0001 Telephone No. USA and Canada: 800-441-5713 International: 207-552-3027

declare that the product Product No.: 0FHF4 Product Name: Weather Finder

is in conformity with Part 15 of the FCC Rules. Operation is subject to the following two conditions: 1) This device may not cause harmful interference. 2) This device must accept any interference received, including interference that may cause undesired operation.

086L004860-029

BAR186A_IM_LLB_EN_NO R_R0 20.11.2007, 10:23 AM 2

Ask about the L.L. Bean Weather Station (0FHF4)

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the L.L. Bean Weather Station (0FHF4)

Be the first to ask — other owners or our team will answer.

Original document

L.L. Bean Weather Station (0FHF4) manual PDF

2 pages·1.6 MB·Weather station·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…