Room Air Conditioner
Model Numbers 78079, 70089, 70129, 78189
I Safety Installation Operation
J _IL CAUTION
Read and follow all safety rules and operating instructions before using this product.
Seam, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A.



Recognize Safety Symbols, Words, and Labels
The following symbols and labels are used throughout this manual to indicate immediate or potential safety hazards. Owner's responsibility is to read and comply with all safety information and instructionsaccompanying these symbols. Failure to heed safety information increases risk of personal injury,property damage, and/or product damage.
CAUTlON_Hazards or unsafe practices which COULD result in minor or moderate personal injury, product damage, or property damage.
I WARNING
To avoid risk of personal injury or death due to electrical shock:
. If two-prong (non-grounding) wall receptacle is encountered, have qualified electrician
replace it with propedy grounded wall receptacle meeting National Electdcal Code and all applicable local codes and ordinances.
- Do not use an extension cord with this air conditioner.
To avoid risk of personal injury,property damage, or product damage due to weight of air conditioner and sharp edges that may be exposed:
- Air conditioners covered in this manual pose excessive weight hazard. Two or more people are needed to
move and install air conditioner. To prevent injury or strain, use proper lifting and carrying techniques when moving air conditioner.
Grounding prong


Every Kenmore Room Air Conditioner has an identification plate showing model number, part number, serial number, and power requirements of unit. identification plate is located behind air filter, attached to the lower left hand side of base pan.
Figure 2. Air Conditioner Internal Parts Identification
Parts and Feature Identification
Figures 1 and 2 show location of air conditioner parts and features described in this manual.
Figure 1. Air Conditioner External Parts Identification
condenser fan, fan motor, and slinger ring) is shown removed for easier component identification.
Electronic control panel


Many complaints about room air conditioners result from units that are over-sized or under-sized for a given area. Over-sized units cool an area before humidity can
be adequately removed, so air feels cold and clammy. Under-sized units do not sufficiently cool an area.
The following table contains guidelines for properly sizing a room air conditioner for a given area.
3, Follow down right-hand column, reading horizontally from square footage to lind approximate air conditioner capacity (in Btus per hour) required to adequately cool designated area.
To size unit:
conditions at bottom of table. For best results, choose air conditioner with cooling capacity (Btus per hour) closest to, but not exceeding, estimated size.
Required Air Conditioner Cooling Capacity--Btu/hour
Size of Area to be Cooled (in square feet)
Room below attic; insulated ceiling above
Room with occupied room above
insulated roof (no attic)
4OO
5OO
60O
t 5000 to 16000
21000 to 230O0
Additional conditions:


Installing Room Air Conditioners Proper installation of a room air conditioner helps ensure trouble-free operation, improper installation can result in problems ranging from excessive noise to property or equipment damage.
Grounding Instructions For safety, air conditioner must be grounded. All air conditioners have power supply cord with three-prong grounding plug. To minimize possible electrical shock hazard, power cord must only be plugged into matching
grounding wall receptacle in accordance with National Electrical Code (and any applicable local codes and ordinances). If appropriate grounding-type wall receptacle is not available, have properly grounded wall receptacle installed by qualified electrician.
Installation requires some mechanical experience and aptitude. Depending upon installer's knowledge and skill, installation of a room air conditioner can take between 1 and 3 hours. Professional installation, performed by authorized Sears technicians, is available. Contact a local Seers store or call 1-800-4-MY-HOME to obtain an estimate and schedule an installation.
If codes permit and separate grounding wire is used, have qualified electrician determine if grounding path is adequate and uninterrupted by plastic, non-metallic
gaskets, or other insulating (non-conductive) materials.
Before Beginning Any Installation • Carefully read all installation instructions. Make sure each step or procedure is understood and any special considerations are taken into account.
A separate (dedicated) circuit is required for units
labeled "Use on Single Outlet Circuit Only." Devices covered inthis manual require a 60Hz supply. Refer to unit nameplate for exact voltage requirements. Voltage requirements can also be determined by type of plug on air conditioner. See Table 1.
- Before starting installation, assemble all tools,
hardware, and supplies needed• Some items may need to be purchased locally.
Table 1. Air Conditioner Power Requirements
Circuit Rating, Breaker, "rime Delay Fuse
NEMA No. 5-15P
I WARNING
To avoid dsk of personal injury or death due to electrical shock:
NEMA No. 6-15P
NEMANo.@I5R
23ei208Vrated at t2 amperesor Is_s
NEMA No. _20P
NEMA No. _20R
NEMANo. _R
25OV-30AMP
208V rated over 16 amperes, but not mot8 _an 24 amperes
Do not use an extension cord. If air conditioner power supply cord does not reach intended wall receptacle, have qualified electrician install or move appropriate receptacle closer to unit.
Do not use an adapter plug. If intended wall receptacle does not match plug on air conditioner, have qualified electrician replace receptacle with correct type.


Receptacle Wiring Receptacle wiring must be of adequate size for unit. Refer to unit identification plate for exact power requirements. Power requirements can also be determined by the type of plug on unit. See Table 1 on preceding page. Minimum size of wiring, based on power requirements, is: Units up to 20 amps: 12 gauge 20-30 amp units: 10 gauge
Window installation kit contains the following parts. Be sure all parts are included before starting installation. If parts are missing, contact Sears.
illustrated in Figure 3. Item #
Window sill gasket (½" x ¼")
Use copper wire only. It is owner's responsibilityto provide proper and adequate receptacle wiring that conforms to all applicable codes. All wiring should be
D
installed by a qualified electrician.
Window Installationn7000 and 9000 Btu
F
G
Units (Models 78079, 70089)
Window seal stdp (3A"x 1½")
Figure 3. Window Installation Kit Parts
To avoid risk of personal injury,property damage, or product damage due to weight of device and sharp edges that may be exposed:
Required Tools and Equipment • Tight-fitting gloves


Installation Requirements See Figure 4. Inspect window track, sash, and sill.
Next, center 6" x 41A"wood block on outside of window sill between sides of window frame. Wood block must be
Ensure window will bear weight of air conditioner for extended period of time. Measure width of window opening to be sure air conditioner will fit.Air conditioner is designed for windows 22½" to 40" wide. Ensure lower left inside corner of window is within 6' of an appropriate electrical outlet.
same thickness as wood strip installed on indoor sill. Attach block to outside sill using 3 countersunk screws.
Mounting kitcan now be installed.
Figure 5. Window Frame Modification
windows that do not have storm windows installed. If storm window is installed, or if installation is in a mobile home, window sill may need modification. See procedure for Storm Window Modification or for Mobile Home Window Modification.
Figure 4. Typical Double-Hung Window
Mobile Home Window Modification
See Figure 6. Mobile home window modification requires adding wood strip at least 1½" wide along entire width of window sill.Thickness of wood strip should match height of front lip of window frame. Fasten wood strip to sill with 3 countersunk wood screws (not provided) to ensure smooth surface for mounting kit.
/ J j' /s I 4 / / / F,
Mounting kit can now be installed.
See Figure 5. if storm window frame does not allow adequate clearance (1' required), remove frame or create clearance by adding wood strip at least 1½" wide and 1" thick along entire width of sill Fasten wood strip to sill with three countersunk wood screws (not provided) to ensure smooth surface for mounting kit.
/ · Storm Window Modification


Figure 6. Modifying Mobile Home Window
Figure 8. Support Bracket Assembly
Figure 9. Installing Support Bracket
Installation Procedure 1. See Figure 7. Raise indoor sash and measure sash width, including portion in window track. Cut window sill gasket (installation Kit Item A) to length of indoor sash and apply to rear of indoor window sill.To apply gasket, peel back about 2" of paper covedng gasket adhesive, and carefully press exposed adhesive to one end of window sill. Slowly peel away remaining paper cover from gasket adhesive, and press gasket to sill as paper is pulled away.
If window has been modified for installed storm window, apply gasket to wood strip added to sill.
For mobile home installation, apply gasket to outdoor side of window frame bottom lip.
Figure 7. Applying Window Sill Gasket
/ · /


. See Figure 9. Place bubble level between indoor silt
. See Figure 11. Position sash bracket (Item E) on top of indoorsash, flush with outdoor sash. Secure bracket to outside sash using %" hex-head screw (Item D). Drill I/e"pilot hole to make screw easier to install.
and outdoor end of support bracket. Turn adjusting foot on support until level tilts ¼ bubble toward outdoor side.
slope should result in ¼" backward slope on installed air conditioner, required for proper water (condensate) drainage.
To prevent damage to window locking or lifting
mechanisms from impropedy placed sash bracket screw, inspect window carefully before ddlling or installing screw in sash.
conditionertop rail.
Figure 11. Installing Sash Bracket
To avoid risk of personal injury, property damage, or damage to air conditioner if unit falls, hold air condi- tioner securely in place until indoor window sash is
securely seated in top rail on outer case.
Figure 10. Placing Air Conditioner inWindow
See figure 12. Expand right side curtain on air conditioner untilcurtain is tight against window frame. With curtain tight against frame, find top hole and mark location on indoor sash. Drill t/8"pilot hole into window sash, and secure curtain to sash using Phillips screw (Item F). Repeat for left side curtain.
Figure 12. Securing Side Curtain
. Use carpenters' level and ensure installed air conditioner slopes approximately ¼" toward outdoor side. If necessary, remove unit from window and turn adjusting foot to obtain proper slope.


. See Figure 13. Slide front grille to left; pull out to
remove. Slide air filter to left; pull out to remove. Remove 4 screws securing front frame to chassis; pull out on front frame to remove.
Figure 13. Removing Front Frame
Figure 15. Installing Seal Strip
Phillips screw (Item F).
Figure 14. Installing Bottom Rail Screw
To begin operation, plug unit into electrical outlet.


A
Window sill gasket (1/z"x ¼")
B
I CAUTION I
D
TO avoid riskof personal injury,property damage, or
product damage due to weight of device and sharp edges that may be exposed:
G
%" sash bracket screw
Window seal strip (_" x 1½")
- Carefully inspect location where air conditioner
will be installed. Be sure it will support weight of
unit for extended period of time.
Figure 16. Window Installation Kit Parts
Window installation kits contain the following parts. Be sure all parts are included before starting installation. If parts are missing, contact Seam.


Installation Requirements See Figure 17. inspect window track, sash, and sill.
See Figure 18. If storm window frame does not allow adequate clearance (¼" required) to window sill, remove frame or create clearance by adding wood strip at f ½" wide along entire width of sill. Fasten wood strip to sill with 3 countersunk wood screws (not provided). Use countersunk screws to ensure a smooth surface for mounting kit.
Ensure window will bear weight of air conditioner for extended period of time. Measure width of window opening to be sure installation kit will fit. Air conditioner is designed for windows 28" to 42" wide. Ensure lower left inside corner of window is within 6' of appropriate electrical outlet.
Mounting kit can now be installed.
windows that do not have storm windows installed. If storm window is installed or if installation is in mobile home, window sill may need modification. See procedure for Storm Window Modification or for Mobile Home Window Modification.
Rgure 18. InstallingWood Strip
Figure 17. Typical Double-Hung Window
/ ti / / _" 3
/./ /
// / J I 4 /" j
Storm Window Modification


Figure 20. Removing Chassis From Outer case
Mobile Home Window Modification
See Figure 19. Mobile home window modification requires adding wood strip at least 1½" wide along entire width of window sill. Thickness of wood strip should match height of front lip on window frame. Fasten wood strip to sillwith 3 countersunk wood screws (not provided) to ensure a smooth surface for mounting kit.
Mounting kit can now be installed.
Figure 19. Modifying Mobile Home Window
See Figure 21. Raise indoor sash and measure sash width, including portion inwindow track. Cut window sill gasket (Installation Kit Item A) to length of indoor sash and apply to rear of indoor window sill. To apply gasket, peel back about 2" of paper covering gasket adhesive, and carefully press
exposed adhesive to one end of window sill. Slowly peel away remaining paper cover from gasket adhesive, and press gasket to sill as paper is pulled
away. If window has been modified for installed storm
window, apply gasket to wood strip added to sill.
Installation Procedure 1. See Figure 20. Slide front gdlle to left; pull out to remove. Slide air filter to left; pull out to remove. Remove 4 screws secudng front frame to chassis; pull out on front frame to remove. Using base pan handle, remove chassis from outer case. Set chassis aside.
For mobile home installation, apply gasket to outdoor side of window frame bottom lip.
Figure 21. Applying Window Sill Gasket
chassis has been pulled out 9" to 12", have two people (one on either side of case) grasp base pan and pull chassis completely out of case.
See Figure 22. Place outer case in window. Lower
indoor sash to fit into top rail on case. Bottom rail on case must sit behind window sill and against window sill gasket.
,


Figure 22. Installing Outer Case in Window
Figure 24. Attaching Adjusting Foot to Outside Support
6, Installoutside supports undemeath case using one!,_" screw (Item E) for each support. Mount vertical arms (tab with hole) as close as possible to sill. When properly positioned, adjusting footfaces
house.
7, See Figure 25. Insert tabs on angled support arms into nearest large holes along bottom of outer case, one side at a time. Align hole in vertical support arm tabs with small holes in bottom of case and ddve ½" screws (Item E) into front tabs.
Figure 25. Attaching Outside Supports to Outer Case 1. Outer case
easier to drive.
Figure 23. Securing Outer Case to Window Sill
, See Figure 24. Screw one 4" adjusting foot into each outside support (Item D) as far as it will go. (Adjustments can be made more easily after unit is in place.) Do not attempt to straighten outside supports or structural integrity of support may be compromised.
//" /// / · /


Figure 27. Installing Sash Bracket
To avoid damage to outside wall of house, especially
if wall is weak or outside supports sit between studs inwall, place wood blocks (not provided) between wall and each adjusting foot.
Figure 26. Adjusting Outer Case Slope
on curtain and mark location on indoor sash. Drill Ve"pilot ho!e into window sash, and secure curtain to sash with Phillips screw (Item H). Repeat for left
Figure 28. Securing Side Curtain
To prevent damage to window locking or lifting mechanisms from improperly placed sash bracket screw, inspect window carefully before drilling or installing screw in sash.
See Figure 27, Position sash bracket (Item F) on top of indoor sash, flush with outdoor sash. Secure bracket to outside sash using 7/8"sash bracket screw (Item G). Drill a 1/8"pilot hole so screw is easier to install.
side curtain, · g,


Figure 29. Installing Seal Strip
Figure 30A. Attaching Chassis To Outer Case
may drip off chassis, To avoid dripping, install condensate drain cup (included with unit). Insert condensate drain cup through %" hole recessed in flange on right side of outer case bottom. Then
place ½" diameter hose or tube on bottom spout of drain cup.
(Models 70129, and 78189) Kenmore Room Air Conditioners with slide-out chassis cases (models 70129, and 78189) are designed to be
Rgure 30. Condensate Drain Cup Installation
installed ina window or through a wall. Following are instructionsare for wall installation.
70089 (7000 and 9000 Btu) are designed for window installationonly. See instructions beginning on page 7.
Figure 31. Slide-Out Chassis Outer Case Dimensions
12000 Btu 18000 Btu
filter, and front grille. Because window sash helps
keep unit in window, make sure sash contacts case before reinstalling chassis.
review all steps and ensure all parts are securely fastened, as outlined in instructions. If final
inspection shows installation is solid and complete, airconditioner can be operated safely.
To begin operation, plug unit into electrical outlet.
Typical Cabinet Dimensions


Brick Veneer or Frame Wall Construction
See Figure 32. Dimensions of finished opening (required) in wall are:
See Figure 33. A framed, finished opening of proper dimensions should be cut out or built into wall. Frame opening with 2" x 4" lumber.
Figure 33. Brick Veneer Wall Opening
Lower left inside comer of opening must be within 6' of appropriate electrical outlet.
For proper condensate drainage when installed, back of case should be %" lower than front of case. Inside edge of case must extend 3,4,beyond inside wall to properly seat air conditioner front cover. After installation, caulk completely around outside of unit to ensure proper seal. Depending upon wall construction and opening location, a lintel (not provided) may be required.
A = 163,4inches 193Ainches
B = 24¼ inches 25718inches
To reinstall chassis and reattach front cover, outer case must be square and level from side to side.
Use wood shims between sides of case and finished opening_especially where case is secured to opening--to prevent warping or distorting case. Check installation with carpenters' square.
To improve appearance, framing inside opening with
decorative molding (not provided) may be desired. If molding is used, mount case in opening so inside edge of case extends _" beyond molding.
To install outer case in opening:
When installing unit through thick walls (12000 Btu unit in walls thicker than 9"; t 8000 Btu unit in walls thicker than 14½"), be sure air flows freely through side louvers on outer case. See Installation in Walls Exceeding Outer
"_aseDimensions.
Figure 32. Typical Wall Opening
_ 12000 Btu 18000 Btu = 16sA inches 19_inches
molding, extend case into room 3A"beyond molding.
or distort case when installing shims.
When pmpedy positioned, secure case in opening with four #10 x 1" (25mm) wood screws (not provided).
General Instructions · = 241/4inches 257/8inches


Figure 34. Secudng Outer Case inWall Opening
Figure 35. Chamfering Walls That Exceed Outer Case
Figure 36. Chamfering Walls That Exceed Outer Case Dimensions (Side View)
12000 Btu I 18000Btu 1 9 inches 14V2inches
Masonry Construction See Figure 32 for dimensions of finished opening to cut out or build into masonry wall. Seal outer case in place with mortar or secure to wall with concrete nails driven through sides of case.
Installation in Walls Exceeding Outer Case Dimensions
Air conditioner must be installed so air flows freely through side louvers to prevent overheating of compressor and fan motor. If dimensions of wall restrict airflow to louvers, wall opening must be modified by chamfering vertical portions of outside opening, as shown in Figures 35 and 36.


EXHAUST CLOSEO I
Figure 37. Touch Control Panel
aid m I I m B B -)i 1 i I I } LOW Fo /oFF "'°" s,vE.O.L*^ V" COOL PLUS
If room temperature is more than 1,5°F above programmed setting, fan continues to run and compressor cycles on to cool room. When room cools to set temperature, compressor and fan turn off and time between air sampling cycles decreases to a minimum of 5 minutes.
See Figure 37. Kenmore room air conditioners have an electronic touch control panel located across top front of unit. Functions and operation of each control are explained below.
To operate touch controls, press control pad until
indicator above pad lights (does not apply to OFF or V IA pads).
FAN ONLY--Fan operates continuously at set speed (high, medium, or tow) and compressor remains off..
Use this setting to circulate air without cooling and, with VENT CONTROL in EXHAUST position, to vent room of stale air, odors, smoke, etc. Displays actual room temperature.
OFF--Turns air conditioner off.
SMART SET--Places air conditioner in "smart" cooling • mode. SMART SET uses computer logic to cool area quickly and quietly. When unit first turns on, fan starts at high speed. As room temperature nears set temperature, fan automatically switches to medium speed, then low speed. When room cools to set temperature, fan continues to run at low speed and compressor cycles on and off to maintain room temperature.
V IA --Used to decrease ("down" arrow) or increase ("up"arrow) set temperature. When used with DELAY START function, arrow keys adjust delay start or stop time.
DELAY START--Allows programming a delay of up to 24 hours before air conditioner starts, or programming air conditioner to automatically stop after up to 24 hours
LOW COOL--Fan operates continuously at low speed, except in power saver mode. If unit is in a cooling mode, compressor cycles on and off as required to maintain set temperature. Select this setting for quietest operation.
of operation. Automatic start or stop is programmable from 1 hour (minimum) up to 24 hours (maximum), in
one hour increments. See Operation Instructions for information on programming air conditioner for delay start or automatic stop.
MED COOL--Fan operates continuously at medium speed, except in power saver mode. If unit is in a cooling mode, compressor cycles on and off as required to maintain set temperature. Select this setting for
Vent control lever, located on lower dght corner of front panel, controls a damper that recirculates or exhausts room air.
reduced air circulation and quieter operation.
HIGH COOL--Fan operates continuously at high speed, except in power saver mode. If unit is in a cooling mode, compressor cycles on and off as required to maintain set temperature. Use this setting for maximum air circulation and faster cool-down during initial start up.
With control in CLOSED position, damper is closed and air in area being cooled is recirculated through air conditioner, filtered, cooled, and returned to room. No air is exhausted (vented) outside.
control should remain closed any time air
POWER SAVER PLUS--Places air conditioner in
conditioner is cooling.
energy-saving mode. Energy-saving mode works in conjunction with SMART SET mode and low, medium, or high fan speeds. In energy-saving mode, air conditioner maintains room temperature within 1.5 ° F of programmed temperature setting. When POWER SAVER PLUS is selected, fan cycles on and off with compressor, instead of running continuously as in other modes. During compressor off cycle, fan automatically turns on for about 2 minutes at 5 minute intervals to
With control in EXHAUST position, damper is open. When open, room air is exhausted (vented) outside.
Usa exhaust position to remove stale or smoky air.
with EXHAUST feature.
Brightness Adjust Feature (some models)
Display brightness can be changed using V I A pad. To decrease brightness, simultaneously press and hold
sample room air temperature. If room temperature is within 1.5°F of programmed temperature, time between sampling increases to a maximum of 15 minutes.
OFF pad with"down" arrow.To increase brightness, press and holdOFF pad with =up" arrow key.
Touch Panel Controls · Vent Control


When area cools to desired temperature, fan speed can be reduced for quieter operation. Compressor will periodically cycle on and off to maintain room temperature at selected level.
To operate air conditioner efficientlyand ensure it
provides maximum comfort:
To operate air conditioner in Smart Set mode:
compressor for 3 minutes after unit is plugged in, I or if restarted less than 3 minutes after last
continuous operation. More frequent cleaning may be
compressor cyc e.
required in extremely dusty environments. NEVER operate air conditioner with air filter removed.
After room reaches set temperature, fan continues to run at low speed and compressor cycles on and off to maintain room temperature.
Power Saver Plus Mode Tooperate air conditioner in Power Saver Plus mode:
To avoid riskof personal injury or death due to electdcal shock:
- DO NOT REMOVE warning tag from power cord.
compressor for 3 minutes after unit is plugged in, or if restarted less than 3 minutes after last compressor cycle.
encountered, have qualified electrician replace it with propedy grounded wall receptacle meeting National Electrical Code and all applicable local codes and ordinances.
2• Press V I/_ pad to set temperature at desired level of cooling.
After room reaches set temperature, fan cycles on and off with compressor. See POWER SAVER PLUS description on previous page.
Normal Cooling Mode Air conditioner is in "normal" coolingmode whenever
Fan Only Mode (No Cooling) Use Fan Only mode for venting area of stale or smoky air, removing odors, or simply circulating air without cooling. Displays actual room temperature. To operate air conditioner in Fan Only mode:
LOW COOL, MED COOL, or HIGH COOL pads are pressed and no other pad is pressed at same time. To run air conditioner in normal coolingmode:
compressor for 3 minutes after unit is plugged in, or if restarted less than 3 minutes after last
compressor cycle.
Smart Set Mode


Adjusting Airflow Direction See Figure 38. Position of air discharge vent louvers determines directionof airflow from vent. Direction can
To program delay start:
be adjusted upward, downward, left, and right.
Figure 38. Airflowfrom Air Discharge Vent
changed within 5 seconds.
5 seconds.
programmed operating mode.
DELAY START pad is not pressed.
To adjust airflowupwardor downward, move horizontal louvers on outsideof air discharge vent up or down.
To adjust airflowleft or right, move airflow directioncontrol lever left or right.
seconds.
In additionto operatingairconditioner in energy-saving mode, savings of energy and money can be realized by:
DELAY START pad is not pressed.
To cancel delay stop program, press DELAY START pad after timer starts counting down, or turn unit off (press OFF pad).
Energy Saving Tips
![Page 23 of the Kenmore 78079 user manual — I WARNING ]](/cdn/reader/ca/cab228e41ca5d253d6d6b1e4e359fc1189dc0bb4c0fada66b486d9291315fce5/images/page-23.webp?w=400)

Normal Operating Sounds Certain sounds may be made when air conditioner runs, especialJy in a cooling mode. Sounds may include:
efficientcompressors.
Maintenance Schedule (below) shows maintenance
requiredto keep unit operating at peak efficiency. Most maintenance can be performed using common tools, equipment, and products.See Maintenance Procedures (beginningon page 24).
To avoid death or personal injury due to electrical shock, turn off fan control and unplug power cord before cleaning orperforming maintenance on this device.
Large maintenance tasks, such as washing condenser and evaporator coils,should performed by an authorized Sears servicer (at owner'sexpense). Call 1-800-4-88- 1222 for location of a local authorized Sears Service Center.
Kenmore Room Air Conditioners are designed and
manufactured to provide years of dependable service when propedy cared for and maintained.
Table 2. Maintenance Schedule
Inspect/clean air filler.
Remove air filler and inspect. Clean if required; replace. NOTE: Never operate air conditioner withfiller removed.
Inspect/clean air discharge Weekly louvers, retum air grille, and electronic control.
Inspect air discharge louvers, returnair grille,and electronic control for dust and dirt accumulation. Clean, if necessary. NOTE: Inspect more often in dustyenvironments.
Inspect louvers on outer case Monthly for obstructions.
Inspect louvers onouter case and remove any obstructions.
Inspect condenser coil. Inspect condenser coil for dirt, bent fins, and other Annually obstructions. Clean/repair, if necessary. ! NOTE: Inspect mare often in dusty environments.
Inspect evaporator coil. Inspect evaporator coil for dirt, bent fins, and other Annually obstructions. Clean/repair, if necessary. NOTE: nspect more often in dusty environments. I Inspect outer case for I Inspect interior and exterior of outer case for scratches, Annually signs of damage, paint blisters, rust, and other damage. Repair as necessary. NOTE: Inspect more often in salty or other corrosive environments.
Inspect/clean base pan. Inspect base pan for scratches, blisters, rust, dents, and other Annually damage. Repair as necessary. Clean condensate drain passages of any accumulated material. NOTE: In areas of excessive humidity, use algicide (algae inhibitor) in base pan to help reduce algae build-up.


Clean air filter by vacuuming. If filter is especially dirty, clean with mild solution of warm soapy water. Rinse filter of all soap residue and dry completely before reinstalling.
Toavoid death or personal injurydue to electrical shock, turn off fan control and unplug power cord before cleaning or performing maintenance on this device.
Optional, disposable air purificationfilter can be mounted behind permanent filterto reduce smoke, odor, pollen, and dust from area being cooled. After approximately 3 months of use, charcoal-impregnated air purificationfilter should be discarded. New air purificationfilters are available from Sears. Order part number:.
Air Filter Removal and Cleaning NOTE: Never operate air conditioner withfilter removed.
Air filter can be removed in two ways:
Optional Air Purification Filter Installation and Removal
Figure 39. Removing Air Filter, Method One
3• Carefully bow center of air purification filter and insert 2 tabs on left side into matching slots on permanent filter frame.
Figure 41. Air Purification Filter Installation and
See Figure 40. Slide return air grille left until insert guides are free of guide rails, then pull insert out and away from front frame. Slide filter left until free of retaining clips.
Figure 40. Air Filter Removal, Method Two
Cleaning Air Discharge Louvers, Return Air
Grille, and Electronic Control Clean air discharge louvers, return air grille, and electronic control with sponge or cloth dampened with mild soap or detergent and water. After cleaning, wipe off soap residue with clean damp cloth and dry. Do not
use cleaners with abrasives or polishing compounds; they may damage air conditioner surfaces.
Air Purification Filter · Removal


Inspecting and Cleaning Base Pan
Inspect base pan. Check fordirt, debds, algae build-up in condensate drain channels, scratches, paint blisters, and
rust spots.
conditionercomponents described below.
To inspect and clean base pan, condenser coil, and evaporator coil, air conditioner chassis must be
removed from outer case. For slide-out chassis models (12000, and 18000 Btu units), remove front grille, air filter, and front frame. Slide chassis out of outer case. Refer to Window Installation instructions for detailed directions.
reduce or eliminate problem of algae build-up. For best results,thoroughly clean base pan of old algae before usingalgicide.
To remove outer case on 7000 and 9000 Btu models:
3, Remove six 5/16" screws secudng expandable curtains to outer case. Three screws are located on each side of outer case. Slide curtain frames away from outer case until they disengage the top and bottom rails.
Inspect outer case. Check for scratches, paint blisters, and rust on both insideand outside of case.
case interior.
Repair scratches, rust, and paint blisters using quality enamel paint. Before painting, remove loose paint and rust with wire brush. Prime rust spots and bare metal with quality metal primer before repainting.
Inspecting and Cleaning Coils Inspect evaporator and condenser coils. Check for bent fins and accumulations of dirt or other debds that may
reduce or block air flow through coils. Reduced or blocked air flow affects air conditioner efficiency and can lead to premature compressor failure.
Attempt to straighten bent fins by "combing" fins with a fine tooth comb. Vacuum (or blow) dirt and debris from
coils. Use brush to loosen difficult accumulations of dirt.
cleaning. Contact a local Sears Service Center for professionalcleaning.
Outer Case Removal · Outer Case Maintenance


The following table describes some common problems that may be encountered with a room air conditioner. Each problem is accompanied by several possible causes and solutions.
Unit will not turn on.
Unit repeatedly blows fuse or trips breaker.
on Single Outlet Circuit Only" require separate, dedicated, circuit. • Ensure fuse is correct size. Unit
requires time-delay fuses. • Ensure circuit breaker is correct size.
this air conditioner. If power cord on air conditioner does not reach outlet
have qualified electrician move out- let or install new outlet closer to unit.
adequately cool room or area.
with filter removed.
not be cleaned. Filter must be
replaced after three months use. • Close all doors and windows in
cooling area. Close all air vents and ducts in area. • Vent Control should be in CLOSED
position whenever air conditioner is
in cooling mode. • Remove any obstruction to airflow from air discharge vent or return air vent on unit.
for information on correctly sizing room air conditioners.


adequately cool room or area.
exposed to direct sunlight. Vent
steam from open cooking containers, showers, etc., from cooling area. Avoid use of heat- producing appliances dudng hottest
part of day. • Clean coils. See Maintenance Procedures.
Unit runs excessively long.
Water (condensate) in o Unit improperly installed. • Depending on model, unit must be base pan ddps into installed with slope of 1,_,to 318"to room. outside. See Installation Instructions.
Unit noisy. • Unit improperly installed, causing vibration when operating.
Check for loose or missing screws. Tighten and replace as required.
Service Authorized Sears service is available nationwide.
Charcoal Air Purification Filter--Used with permanent air filter, disposable charcoal air purificationfilter further
Professional technicians, trained by Sears, ensure any required service is performed quickly and correctly, usingonly authorized replacement parts.
reduces smoke, pollen, dust, pet dander, and odors in cooled area. Order part number 20056001 (7000 and 9000 Btu units), 20064601 (12000 Btu units), or 20075401 (18000 Btuunits). Accessories for Kenmore Room Air Conditioners are available at local Sears stores or can be ordered bycalling 1-800-366-PART (1-800-366- 7278) any time between 7 am and 7 pm, 7 days a week.
For additional protection, consider a Sears maintenance agreement. Like all Sears appliances, Kenmore Room Air Conditioners are designed and manufactured to provide years of dependable operation. Every unit is tested-- during manufacturing and before shipping--to ensure it works propedy. But, like all mechanical devices, some service may be required over the life of the unit. A Sears
Ordering Replacement Parts Replacement parts are available at many local Sears stores or can be ordered by calling 1-800-366-PART
maintenance agreement, in conjunction with the Sears warranty, provides the best insurance available against
(1-800-366-7278) any time between 7 am and 7 pro, 7 days a week.
unexpected repair bills. Call 1-800-827-6655 for information.


Call 24 hours a day, 7 days a week 1-800-4-MY-HOM E'" (1-800-469-4663)
Au Canada pour tout le service - 1-877-LE FOYER 'M (1-877-533-6937)
For the repair or replacement parts you need: Call 6 a.m. - 11 p.m. CST, 7 days a week
Para ordenar piezas - 1-800-659-7084
For a Sears Service Center location in your area: Call 24 hours a day, 7 days a week
For a Sears Maintenance Agreement purchase or inquiry: Call 7 a.m.-5 p.m. CST, Monday-Saturday 1-800-827-6655
Part No, 20101102 Printed in U.S.A.