Instruction/ maintenance manual of the product CV-A33CL JAI
Go to page of 26
Digital Monochrome Quad Speed CMOS Progressive Scan Camera CV -A33CL Operation Manual Camera: Revision A Manual: Version 1.0 A33Manualsep09.doc JPT 09 -09-03.
CV-A33CL - 1 - Table of Contents 1. General ........................................................................................................ 2 2. Standard Co mposition ...........................................................................
CV-A33CL 1. Gener al The CV-A33CL is a digital CMOS camera design ed for automated imaging applications, featuring high speed within a uniform and compact housing.
CV-A33CL 4. Locations and F unctions U4-40 機銘版 17 .5 50 58 50 26 5 4- M3深4 M3深 4 (0 .2 ) (2 .28 ) (0 .69 ) (1 .97 ) (1 .02 ) (1 .97 ) 8 (0 .31 ) (0 .3 ) 7. 6 5 (0 .2 ) 44 35 C- Moun t (1 .73 ) (1 .38 ) /O DI GI T A L I IN / DC TR IG 26 (1 .02 ) 5 4xM3 Depth 4 5 4 コネクタ ー 固定ネシ ゙ 2 1 6- 4xM3 Depth 4 3 5 5 1.
CV-A33CL - 4 - 5. Pin Assignment 5.1. 12-pin Multi-conne ctor (DC-IN/Trigger) Type: HR10A-10R-12PB-01 Pin no. Signal Remarks 1 GND 2 +12 V DC input 3 GND 4 N/C 5 GND 6 RXD in 7 TXD out RS 232C. Or via Camera Link by internal SW200 on PK8378A (Off=HR) 8 GND 9 EEN out And via Camera Link 10 Trigger input Or via Camera Link.
CV-A33CL 5.3. Input and Output Circuits 5.3.1. Trigger input The trigger inputs on pin #10 12 pin Hirose connector is AC coupled. To allow a long pulse width, the input circuit is a flip flop , which is toggled by the negative or positive differentiated spikes caused by the falling or rising trigger edges.
CV-A33CL 5.3.3. Camera Link interface The video output is Camera Link with 10 or 8 b it video placed in a base configuration. The digital output signals follow the Camera Lin k standardized multiplexed signal o utput interface. The Camera Link output driver is NS typ e DS90CR285MTD.
CV-A33CL - 7 - 6. F unctions and Oper ations In the following the format shown in “7.3. CV-A33CL command list” are used for function commands and parameters. 6.1. Basic functions The CV-A33CL camera is a progressive scan camera with 10 or 8 b it video output in single channel Camera Link.
CV-A33CL - 8 - 6.1.3. Column Process The voltage signal from a single pix el is send to the column amplifier trough the 4 to 1 multiplexer. After the S/H circuit, the offset and gain calibrating is perform. A 10 bit A/D c onverter send the digital pixel signal to the digital horizontal shift register by a 1 to 4 multiplexing.
CV-A33CL - 9 - 6.1.6. Window of Interest If a higher frame rate is wanted, it is poss ible to change the CMOS sensors sensin g area to the window of interest.
CV-A33CL - 10 - 6.2. Sensor layout and timing. 6.2.1. Effective image format The drawing below shows the effective pixels on the CCD array with respect to pixels and lines as it is used in the timing and vide o read out. (0, 0) (658, 492) Active Pixel Array 659 493 Minimum window size 3 2 Fig.
CV-A33CL - 11 - 6.2.4. LVAL a-synchr onous accumulation The CV-A33CL has LVAL a-sy nchronous accumulations only. The accumulation will start 28 µ sec. after the trigger leading edge. EEN will indicate the accumulation time. When the accumulation stops after the selected shutter time, the LVAL phase is reset and restarted.
CV-A33CL - 12 - 6.2.5. Timing for wind ow of interest With WS=1, the X and Y start coordinates (WX and WY), and the width and height (WW and WH) for the window of interest can be pr ogrammed with 1 pixel interval. Th e minimum window size is 2(h) x 3 (v).
CV-A33CL - 13 - 6.3. Input/Output of Timing Signals 6.3.1. Input of Timing Signals It is not possible to synchronize the camera from an external sync source except by an extern trigger pulse. The camera will al ways run with its internal X-tal controlled timing.
CV-A33CL - 14 - 6.4.1. Continuous Operation (Non triggered) Mode settings can be done with RS-232C. Trigger Mo de Normal. TR=0. It is for applications where the camera is continuous running without external trigger. The shutter mode can be norm al or programmable exposure.
CV-A33CL - 15 - DVA L DA TA O UT FVA L LVA L EE N pe r iod E xpo su re T R G 27 .6 μ S ( When the e xpo su r ei s m i n . ( P E = 2 ) ) 01234 Eff e ct i v e L i n e s 493L 5L 4 8 8 4 9 0 4 8 9 4 9 1 4 9 2 …… …… 498L 1F V A L p e r i o d 2L 2L 502L 1 LVAL = 16.
CV-A33CL - 16 - 6.4.3. Pulse Width Co ntrol Mode The exposure will start 28 µ sec. after the trigger leading edge, and it stops and is read out at the trigger trailing edge.
CV-A33CL - 17 - 6.4.4. Auto trigger Mode The auto trigger function, TR=3 can be used as sens ing device inside the camera field of view. It sense in a programmable window from top of the image. The continuous output is sent to the frame grabber, which P C should be programme d to sense if an object is passing the window.
CV-A33CL - 18 - 6.5. Other Functions. User ID. The command ( UD ) the user can save up to 16 characters in the camera to identify the camera. Bit Allocation. The command ( BA ) will select the number of bits in the Camera Link output to 8 o r 10 bit. Black Level.
CV-A33CL - 19 - 7.2. RS-232C control All configuration of the CV-A33CL camera is done via the RS-232 C port on the 12 pin HR connector or via Camera Link. (Internal switch SW200 off for HR). The camera can be set up from a PC running terminal emulator software , or using JAI´s camera control software.
CV-A33CL - 20 - 7.3. CV-A33CL command list Command Name Format Parameter Remarks A – General settings and useful commands EB Echo Back EB= [ Param. ] <CR><LF> 0=Echo off 1=Echo on Off at.
CV-A33CL - 21 - 7.4. Camera Control Tool for CV-A33 From www.jai.com Camera Control Tool for Windows 98/NT/2000 can be downloaded. The control tool contents a camera control program and tools for m aking your own program. For the integrator and experienced user, the Camera Control Toll is much more than a program with a window interface.
CV-A33CL - 22 - 8. External Appear ance and Dimensions ) ) 機銘版 17 .5 26 50 58 50 26 5 4 (0 .2 ) (2 .28 ) (0 .69 ) (1 .97 (1 .02 ) (1 .02 ) (1 .97 8 (0 .31 ) (0 .3 ) 7. 6 5 (0 .2 ) 44 35 C- Moun t (1 .7 3 ) (1 .38 ) /O DI GI T A L I IN / DC TR IG 定ネシ ゙ コネクター 固 U4-40 6- M3深4 4xM3 Depth 4 4- M3深 4xM3 Depth 4 Fig.
CV-A33CL - 23 - 9.2. Specification table Specifications CV-A33CL Scanning system Progressive scan Pixel clock 40.000 MHz (25 nsec) Line frequency 59.44 kHz (673 pixels cl ock/line) (16.
CV-A33CL - 24 - 10. Appendix 10.1. Precautions Personnel not trained in dealing with similar elec tronic devices should not service this camera. The camera contains components sensitive to el ectrostatic discharge. The handling of these devices should follow the requirements of electrostatic se nsitive components.
CV-A33CL - 25 - 11. Users Record Camera type: CV-A33CL Revision: (Revision A) Serial No. …………….. Firmware version. …………….. Camera ID. …………….. Model name. …………….. User ID. …………….. For camera revision hi story, please contact your local JAI d istributor.
An important point after buying a device JAI CV-A33CL (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought JAI CV-A33CL yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data JAI CV-A33CL - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, JAI CV-A33CL you will learn all the available features of the product, as well as information on its operation. The information that you get JAI CV-A33CL will certainly help you make a decision on the purchase.
If you already are a holder of JAI CV-A33CL, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime JAI CV-A33CL.
However, one of the most important roles played by the user manual is to help in solving problems with JAI CV-A33CL. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device JAI CV-A33CL along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center