Page 1 of the Invacare LC33 user manual — TECHNICAL SPECIFICATIONS
Page 1 · click to enlarge
Page 1
Invacare LC33 —   diagram (page 1)
Fig. 1

SAFETY SUMMARY The following recommendations are made for the safe installation and proper operation of the Invacare Lift-Out Chair:

NAME MODEL NO. COLOR

Murphy LC11 Beige LC12 Ocean Blue LC13 Mauve Fairview LC21-1 Light Brown LC22-1 Blue LC23-1 Burgundy LC24-1 Green Stanford LC31 Toast LC32 Blue LC33 Mauve LC34 Green Woodbriar LC41 Beige LC42 Blue LC43 Mauve LC44 Green Manchester LC51-1 Chestnut Brown LC52-1 Midnight Blue LC53-1 Burgundy LC54-1 Evergreen LC55 Beige LC56 Black LC57 Burgundy LC58 Hunter Green Jamestown LC61 Navy LC62 Royal Blue LC63 Burgundy LC64 Hunter Green New Yorker LC75 Beige LC76 Green LC77 Burgundy LC78 Black BellAire LC85 Cocoa Brown LC86 Deep Blue LC87 Mahogany LC88 Forest Green

GENERAL WARNINGS DO NOT operate this equipment without first reading and understanding this instruc- tion sheet. If you are unable to understand the Warnings, Cautions, and Instructions, contact a healthcare professional, dealer or technical personnel if applicable be- fore attempting to use this equipment - oth- erwise injury or damage may result.

After ANY adjustments, repair or service and BEFORE use, make sure all attaching hardware is tightened securely.

DO NOT move the chair when occupied.

DO NOT sit on the ottoman. It is not de- signed as a seating area.

DO NOT stand on the ottoman when en- tering or exiting the chair. The chair WILL tip and bodily injury may occur.

Always leave chair in an upright (closed) position when not in use. DO NOT leave the chair in the elevated position.

DO NOT operate the seat lift movement of your chair with anyone seated on your lap or on the arms of the lift chair/power recliner.

The hand held pendant control is designed to be operated by the occupant only.

DO NOT allow children to play on or oper- ate the chair. The ottoman folds down on closing; a child could sustain injury. Keep hands and feet clear of ottoman and scis- sors mechanism.

TECHNICAL SPECIFICATIONS

Voltage:115 VAC Frequency:60 Hz Power:130 Watts Duty Cycle:Intermittent duty 2 min ON/18 min OFF Weight Capacity:350 lbs (160 kg)

Ensure that legs and arms do not come in contact with moving parts of the chair. If it is necessary to retrieve items that may have fallen under the chair, make certain the chair is unplugged before proceeding. When sitting on elevated chair, center your weight in the chair.

Page 2 of the Invacare LC33 user manual — Reclining The Chair
Page 2 · click to enlarge
Page 2

SAFETY SUMMARY (CONTINUED)

DO NOT operate the chair more than two (2) minutes every twenty (20) minutes (2 minutes ON/ 18 minutes OFF). If the chair is operated excessively, the protective thermal overload switch will shut off the motor. If this occurs, it may take several hours for the motor to cool down and reset the ther- mal ateoverload switch. The chair will operagain once the motor has cooled off. Lift ecline B FI ng/Lo ding P : Refer TY SU WARNING Whe posi This call shor you you or pn sitting on the chair in the elevated tion, center your weight in the chair. chair is designed to stop automatiy at its fully raised height. If you are a ter person, raising the chair beyond r normal standing height may cause to slide toward the front of the seat ossibly fall from the chair.
GENERAL WARNINGS Exercise extreme caution if there is a power failure when chair is in fully reclined position. User should be aware that when the power fails the lift out chair will not operate and is advised to find assistance when exiting chair. WEIGHT LIMITATION The Lift-Out Chair can NOT be used by individuals weighing more than 350 lbs (160 kg.) . N an NOT be used by indire than 350 lbs (160 kg.) POSITIONING T CHAIR 1. Make certain there is chair. With the chair i there must be 18-inch the top of the chair ba obstruct the back or th 2. Remove the cardboa ping) from the bottom all staples holding the moved or not sticking will alleviate any rubbi CAHE LIF adequate ro n the closed es (45 cm) of ck and the w e ottoman a rd corner p of the chair cardboard up from the ng with the lif UTION All staples holding pads MUST be rem from the wood fra damage may resulthe card oved or n me-other t.board corner ot sticking up wise injury or OPERATION (FI NOTE: Refer to the G SAFETY SUMMARY o NOTE: The chair's lift-out by a hand held pendant c will raise the chair to a st recline button will lower th The chair will stop movinGURE ENERAL W f this Instru and power ontrol. Depre anding positi e chair to a fl g when the b CAUTION DO NOT operate t mode without som will cause unneceshe chair eone in t sary strainin the recline he chair. This on the motor.
1. Perform one (1) of the following.

A. To raise the chair to the standing position, depress and hold the Lift Button until the chair is at the most comfortable position to enter or exit.

B. To lower the chair back to the seated position,

depress and hold the Recline Button.

Reclining The Chair

1. Perform one (1) of the following.

A. To recline the chair, depress and hold the Re-

cline Button until the chair has reclined to the desired position.

B. To raise the chair back to the seated position,

depress and hold the Lift Button.

Page 3 of the Invacare LC33 user manual — REPOSITIONING THE PENDANT HAND CONTROL (FIGURE 2)
Page 3 · click to enlarge
Page 3

REPOSITIONING THE PENDANT HAND CONTROL (FIGURE 2)

18. Plug the chair power cord into the wall.
19. Press the pendant button in the recline direction until the lift mechanism returns to the seating position and just makes contact with the wood chair frame.
1. Place the chair into the seated position.
2. Unplug the motor power cord from the wall.
3. Remove the screws and cable clamps securing the pendant cable to the underside of the armrest.
4. Remove the screw and cable clamp securing the pendant cable to the back of the chair. 5. Roll the chair forward onto the ottoman and the front of the seat back.
20. Press the pendant button in the recline direction to produce sufficient slack in the rear flap of fabric to thread the pendant back out through the flap.
21. Unplug the chair power cord from the wall. 22. Return the chair back onto all four (4) feet.
6. Plug the motor power cord into the wall. 7. Press the pendant button in the recline direction slightly to produce sufficient slack in the flap of fabric to thread the pendant in through the flap.
23. Pull the pendant cable tight and secure the pendant cable to the rear of the chair with a screw and cable clamp. 24. Perform one (1) of the following:
8. Press the pendant button in the lift direction until the lift mechanism is fully raised.

A. Murphy, Fairview, and Woodbriar models- proceed to STEP 25. B. Stanford, Bellaire, Manchester, and

9. Unplug the chair power cord from the wall. 10. Remove the screw and cable clamp from the side of the rear corner of the chair. 11. Remove the screw and cable clamp from the middle of the side of the chair.

Jamestown models - tightly pull the pendant cable to the bend in the armrest. Secure the pendant cable under the bend in the armrest with a screw and cable clamp.

12. Remove the cable tie securing the pendant cable to the lift frame.

C. New Yorker model - tightly pull the pendant cable

to the back end of the armrest. Secure the pen- dant cable under the back end of the armrest with a screw and cable clamp. 25. Secure the pendant cable to the outer side of the chair immediately under the armrest half way be- tween the front of the armrest and the seat back according to following.

13. Pull the pendant cable to a spot 7-1/2-inches from the inside of the rear 1-inch square frame tube as shown in DETAIL "A" of FIGURE 2.
14. Secure the pendant cable to the lift frame with a cable tie at the point closest to the cable as shown in DETAIL "B" of FIGURE 2.

A. Murphy, Fairview, Stanford models - the screw must be placed vertically up into the underside of the armrest as shown in FIGURE 2. B. Woodbriar model - the screw must be placed

vertically down into the frame of the chair as shown in FIGURE 2.

15. Secure the pendant cable to the middle of the side of the chair with a screw and cable clamp. As shown in DETAIL "B" of FIGURE 2.

C. New Yorker, Bellaire, Manchester, Jamestown

models - the screw must be placed horizontally into the side of the chair as shown in FIGURE 2.

16. Pull the pendant cable tight along the side of the chair to the rear corner of the chair.
17. Secure the pendant cable to the side of the rear corner with no slack in the cable. As shown in DETAIL "B" of FIGURE 2.
Page 4 of the Invacare LC33 user manual — REPOSITIONING THE PENDANT HAND CONTROL (FIGURE 2)
Page 4 · click to enlarge
Page 4
Invacare LC33 — REPOSITIONING THE PENDANT HAND CONTROL (FIGURE 2) diagram (page 4)
Fig. 2

DETAIL “A” Cable Clamp and Screw (As Close to Corner as Possible)

Page 5 of the Invacare LC33 user manual — Lubrication Points (FIGURE 3)
Page 5 · click to enlarge
Page 5

GENERAL MAINTENANCE

CLEANING INSTRUCTIONS

Fabric Cleaning

UPHOLSTERY Clean only with water-based shampoo or foam upholstery cleaner.

Pile fabrics may require brushing to restore ap- pearance.

Naugahyde®

For best results, remove staining immediately. The longer the staining is allowed to set the more diffi- cult the stain is to remove. Blot all excess staining residues. Always use a clean soft damp cloth when utilizing the following cleaning methods.

Lubrication Points (FIGURE 3)

For Light Soiling: A solution of 10% household liquid dish soap with warm water applied with a soft damp cloth will re- move most soiling.

1. Ensure that the plug is connected to an operating electrical outlet, and ensure that the pendant cord is plugged into the motor socket.

If necessary, use a solution of liquid cleanser and water applied with a soft bristle brush. Wipe away the resi- due with a water-dampened cloth.

2. Raise the chair to the highest position to access the clevis pins.

For More Difficult Stains: Dampen a soft white cloth with a solution of house- hold bleach (sodium hypochlorite); 1 part bleach, 4 parts water.

3. Unplug the chair.
4. Roll the chair forward onto the ottoman and the front of the seat back.
5. Perform the following to one (1) clevis pin one at a time (12 in all) as in FIGURE 3 - LUBRICATION POINTS in this INSTRUCTION SHEET :

Rinse with a water-dampened cloth to remove bleach concentration.

A. Remove hitch pin securing clevis pin to the frame.

B. Remove clevis pin.

If necessary , allow a 1:4 diluted bleach solution to puddle on the affected area of apply with a solution soaked cloth for approximately 30 minutes. Rinse with a water-dampened cloth to remove any remaining bleach concentration.

C. Apply small amount of wheel bearing grease to

the clevis pin.

D. Reverse STEPS A-B. to install clevis pin.

6. Repeat STEP 5 on remaining clevis pins.
7. Repeat STEPS 1-4 to roll the lift out chair back into the upright position.

Naugahyde is a registered trade mark of Uniroyal

Rub gently

Page 6 of the Invacare LC33 user manual — Please Review Carefully
Page 6 · click to enlarge
Page 6

Please Review Carefully

Motor and Pendant Cleaning

Should you choose other cleaning methods or other clean- ing agents, carefully try them in an inconspicuous area to determine potential damage to the material. Never use harsh solvents or cleaners intended for industrial applica- tions. To clean stained or soiled areas, a soft white cloth is recommended. Avoid use of paper towels.

Unplug the chair from the wall before cleaning the motor or pendant. The motor and pendant may be cleaned with a damp cloth or sponge.

Stains such as lipstick, crayon, felt tip pens, ballpoint pen, certain dyed suntan lotions or mustard, etc. must be cleaned immediately. The longer these and other similar harsh/permanent stains are exposed to the vinyl surface, the more difficult the vinyl will be to clean. In some cases, removal of certain stains is impossible.

Cleaning agents should be free of acids or salt water.

Dry the motor and pendant thoroughly after clean- ing before returning the chair to service.

Page 7 of the Invacare LC33 user manual — Please Review Carefully
Page 7 · click to enlarge
Page 7
Invacare LC33 — Please Review Carefully diagram (page 7)
Fig. 3 · Please Review Carefully

1 Glide 2 Tube Closure 3 Screw 4 Cable Clamp 5 Hex Head Serrated Flange Screw 6 Twinfast Wood Screw 7 Plug Button 8 Hitch Pin 9 Clevis Pin 10 Cable Tie 11 Pan Head Screw 12 Nut, Self Locking 13 Transformer 14 Motor 15 Pendant 16 Lift Frame Assembly 17 Lockout key (Canadian) 18 Screw 19 Cable Clamp 20 Bushing

Page 8 of the Invacare LC33 user manual — LIMITED WARRANTY
Page 8 · click to enlarge
Page 8

LIMITED WARRANTY

PLEASE NOTE: THE WARRANTY BELOW HAS BEEN DRAFTED TO COMPLY WITH FEDERAL LAW APPLICABLE TO PRODUCTS MANUFACTURED AFTER JULY 4, 1975.

This warranty is extended only to the original purchaser/user of our products.

This warranty gives you specific legal rights and you may also have other legal rights which vary from state to state.

Invacare warrants electrical and mechanical components for a period of three (3) years from the date of purchase. Upholstery fabric is warranted for a period of three (3) years from date of purchase. If within such warranty period any such product shall be proven to be defective, such product shall be repaired or replaced, at Invacare’s option. This warranty does not include any labor or shipping charges incurred in replacement part installation or repair of any such product. Invacare’s sole obligation and your exclusive remedy under this warranty shall be limited to such repair and/or replacement.

For warranty service, please contact the dealer from whom you purchased your Invacare prod- uct. In the event you do not receive satisfactory warranty service, please write directly to Invac- are at the address located at the bottom of this page, provide dealers name, address, date of purchase, indicate nature of the defect and, if the product is serialized, indicate the serial num- ber. Do not return products to our factory without our prior consent.

LIMITATIONS AND EXCLUSIONS: THE FORGOING WARRANTY SHALL NOT APPLY TO SERIAL NUM- BERED PRODUCTS IF THE SERIAL NUMBER HAS BEEN REMOVED OR DEFACED, PRODUCTS SUB- JECTED TO NEGLIGENCE, ACCIDENT, IMPROPER OPERATION, MAINTENANCE OR STORAGE, COM- MERCIAL OR INSTITUTIONAL USE, PRODUCTS MODIFIED WITHOUT INVACARE’S EXPRESS WRITTEN CONSENT INCLUDING, BUT NOT LIMITED TO, MODIFICATION THROUGH THE USE OF UNAUTHO- RIZED PARTS OR ATTACHMENTS; PRODUCTS DAMAGED BY REASON OF REPAIRS MADE TO ANY COMPONENT WITHOUT THE SPECIFIC CONSENT OF INVACARE, OR TO A PRODUCT DAMAGED BY CIRCUMSTANCES BEYOND INVACARE’S CONTROL, AND SUCH EVALUATION WILL BE SOLELY DE- TERMINED BY INVACARE. THE WARRANTY SHALL NOT APPLY TO PROBLEMS ARISING FROM NOR- MAL WEAR OR FAILURE TO ADHERE TO THESE INSTRUCTIONS.

THE FOREGOING WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS WARRANTIES. IMPLIED WARRANTIES, IF ANY, INCLUDING THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, SHALL NOT EXTEND BEYOND THE DURATION OF THE EXPRESS WARRANTY PROVIDED HEREIN AND THE REMEDY FOR VIOLATIONS OF ANY IMPLIED WARRANTY SHALL BE LIMITED TO REPAIR OR REPLACEMENT OF THE DEFECTIVE PRODUCT PUR- SUANT TO THE TERMS CONTAINED HEREIN. INVACARE SHALL NOT BE LIABLE FOR ANY CONSE- QUENTIAL OR INCIDENTAL DAMAGES WHATSOEVER. SOME STATES DO NOT ALLOW THE EXCLU- SION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGE, OR LIMITATION ON HOW LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE EXCLUSIONS AND LIMITATIONS MAY NOT APPLY TO YOU.

THIS WARRANTY SHALL BE EXTENDED TO COMPLY WITH STATE/PROVINCIAL LAWS AND REQUIREMENTS.

Invacare LC33 — LIMITED WARRANTY diagram (page 8)
Fig. 4

!"# $% &

'( ))*+,'(' -. */ 0,***,+ ,0,00*0 1 2 *,0 3 2 *$+ . 4(5 '6(

Ask about the Invacare LC33

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Invacare LC33

Be the first to ask — other owners or our team will answer.

Original document

Invacare LC33 manual PDF

8 pages·360 KB·Mobility Aid·PDF
Click any page above to open it here