EN
InFocus logo
Official user manual

InFocus DV 18V

8 pages·321 KB·Impact Driver·PDF·ENDEFRITNLJA
InFocus DV 18V
Table of Contents 16 sections Impact Drill Model DV 18V · Handling instructions · GENERAL OPERATIONAL PRECAUTIONS · PRECAUTIONS ON USING IMPACT DRILL · … ShowHide
Page 1 of the InFocus DV 18V user manual — Impact Drill Model DV 18V
Page 1 · click to enlarge
Page 1

Impact Drill Model DV 18V

Handling instructions

InFocus DV 18V — Impact Drill Model DV 18V diagram (page 1)
Fig. 1 · Impact Drill Model DV 18V
Page 2 of the InFocus DV 18V user manual — PRECAUTIONS ON USING IMPACT DRILL
Page 2 · click to enlarge
Page 2

17. Avoid unintentional starting. Do not carry a plugged- in tool with a finger on the switch. Ensure switch is off when plugging in. 18. Use outdoor extension leads. When tool is used outdoors, use only extension cords intended for outdoor use. 19. Stay alert. Watch what you are doing. Use common sense. Do not operate tool when you are tired. 20. Check damaged parts. Before further use of the tool, a guard or other part that is damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for alignment of moving parts, free running of moving parts, breakage of parts, mounting and any other conditions that may affect its operation. A guard or other part that is damaged should be properly repaired or replaced by an authorized service center unless otherwise indicated in this handling instructions. Have defective switches replaced by an authorized service center. Do not use the tool if the switch does not turn it on and off. 21. Warning The use of any accessory or attachment, other than those recommended in this handling instructions, may present a risk of personal injury. 22. Have your tool repaired by a qualified person. This electric tool is in accordance with the relevant safety requirements. Repairs should only be carried out by qualified persons using original spare parts. Otherwise this may result in considerable danger to the user.

GENERAL OPERATIONAL PRECAUTIONS

1. Keep work area clean. Cluttered areas and benches invite injuries. 2. Consider work area environment. Do not expose power tools to rain. Do not use power tools in damp or wet locations. Keep work area well lit. Do not use power tools where there is risk to cause fire or explosion. 3. Guard against electric shock. Avoid body contact with earthed or grounded surfaces. (e.g. pipes, radiators, ranges, refrigerators). 4. Keep children and infirm persons away. Do not let visitors touch the tool or extension cord. All visitors should be kept away from work area. 5. Store idle tools. When not in use, tools should be stored in a dry, high or locked up place, out of reach of children and infirm persons. 6. Do not force the tool. It will do the job better and safer at the rate for which it was intended. 7. Use the right tool. Do not force small tools or attachments to do the job of a heavy duty tool. Do not use tools for purposes not intended; for example, do not use circular saw to cut tree limbs or logs. 8. Dress properly. Do not wear loose clothing or jewelry, they can be caught in moving parts. Rubber gloves and non-skid footwear are recommended when working outdoors. Wear protecting hair covering to contain long hair. 9. Use eye protection. Also use face or dust mask if the cutting operation is dusty. 10. Connect dust extraction equipment. If devices are provided for the connection of dust extraction and collection facilities ensure these are connected and properly used. 11. Do not abuse the cord. Never carry the tool by the cord or yank it to disconnect it from the receptacle. Keep the cord away from heat, oil and sharp edges. 12. Secure work. Use clamps or a vise to hold the work. It is safer than using your hand and it frees both hands to operate tool. 13. Do not overreach. Keep proper footing and balance at all times. 14. Maintain tools with care. Keep cutting tools sharp and clean for better and safer performance. Follow instructions for lubrication and changing accessories. Inspect tool cords periodically and if damaged, have it repaired by authorized service center. Inspect extension cords periodically and replace, if damaged. Keep handles dry, clean, and free from oil and grease. 15. Disconnect tools. When not in use, before servicing, and when changing accessories such as blades, bits and cutters. 16. Remove adjusting keys and wrenches. Form the habit of checking to see that keys and adjusting wrenches are removed from the tool before turning it on.

PRECAUTIONS ON USING IMPACT DRILL

1. Before drilling into walls, ceilings or floors, ensure that there are no concealed power cables inside. 2. Always use side handle and hold the tool firmly with both hands. 3. Always use the impact drill with clockwise rotation, when using it as an impact drill. ( Fig. 1 )
Page 3 of the InFocus DV 18V user manual — PRIOR TO OPERATION
Page 3 · click to enlarge
Page 3
InFocus DV 18V — STANDARD ACCESSORIES diagram (page 3)
Fig. 2
Voltage (by areas)*(110V, 220V, 230V, 240V) Power input690 W* Speed change12 No load speedForward rotation0 – 1000 min-10 – 3000 min-1 Reverse rotation0 – 600 min-10 – 1800 min-1 CapacitySteel13 mm8 mm Concrete18 mm13 mm Wood40 mm25 mm Full load impact rate8400 min-127300 min-1 Weight (without cord)2.0 kg

*Be sure to check the nameplate on product as it is subject to change by areas.

STANDARD ACCESSORIES

5. Mounting and dismounting of the bit. For keyed chuck (Fig. 2)

(1) Chuck Wrench (Spec. only for keyed chuck) 1 (2) Side Handle 1 (3) Depth Gauge 1 Standard accessories are subject to change without notice.

(1) Open the chuck jaws, and insert the bit into the

chuck. (2) Place the chuck wrench in each of the three holes

in the chuck, and turn it in the clockwise direction (viewed from the front side). Tighten securely. (3) To remove the bit, place the chuck wrench into one

OPTIONAL ACCESSORIES (sold separately)

of the holes in the chuck and turn it in the counterclockwise direction.

(1) Impact Drill Bit (for concrete)

3.2 mm – 18 mm dia. Optional accessories are subject to change without notice.

Drill chuck Chuck wrench

InFocus DV 18V — OPTIONAL ACCESSORIES (sold separately) diagram (page 3)
Fig. 3 · OPTIONAL ACCESSORIES (sold separately)

APPLICATIONS

By combined actions of ROTATION and IMPACT:

Boring holes in hard materials (concrete, marble, granite, tiles, etc.) By ROTATIONAL action:

Boring holes in metal, wood and plastic.

PRIOR TO OPERATION

For keyless chuck (Fig. 3)

1. Power source Ensure that the power source to be utilized conforms to the power requirements specified on the product nameplate. 2. Power switch Ensure that the power switch is in the OFF position. If the plug is connected to a receptacle while the power switch is in the ON position, the power tool will start operating immediately, inviting serious accident. 3. Extension cord When the work area is removed from the power source, use an extension cord of sufficient thickness and rated capacity. The extension cord should be kept as short as practicable. 4. Selecting the appropriate drill bit When boring concrete or stone

(1) Mounting the bit

Turn the sleeve counterclockwise and open the chuck. After inserting the drill bit into the chuck as far it will go, grip the retaining ring and close the chuck by turning the sleeve clockwise as viewed from the front. (2) Dismounting the bit

Grip the retaining ring and open the chuck by turning the sleeve counterclockwise.

InFocus DV 18V — PRIOR TO OPERATION diagram (page 3)
Fig. 4

Use the drill bits specified in the Optional Accessories. When boring metal or plastic

Use an ordinary metalworking drill bit. When boring wood

Use an ordinary woodworking drill bit. However, when drilling 6.5 mm or smaller holes, use a metalworking drill bit.

Sleeve

Page 4 of the InFocus DV 18V user manual — NOTE
Page 4 · click to enlarge
Page 4

NOTE

To attach a depth gauge on the side handle, insert the gauge into the U-shaped groove on the side handle, adjust the position of the depth gauge in accordance with the desired depth of the hole, and firmly tighten the side handle grip. (Fig. 7)

When the sleeve does not become loose any further, fix the side handle to retaining ring, hold side handle firmly, then turn the sleeve to loosen by hand. (Fig. 4)

InFocus DV 18V — NOTE diagram (page 4)
Fig. 5
InFocus DV 18V — NOTE diagram (page 4)
Fig. 6

Fig. 4 6. Check the rotational direction (Fig. 5) The bit rotates clockwise (viewed from the rear side) by pushing the R-side of the push button. The L-side of the push button is pushed to turn the bit counterclockwise. (The L and R marks are provided on the body.) CAUTION Always use the impact drill with clockwise rotation, when using it as an impact drill.

Fig. 7 8. IMPACT to ROTATION changeover (Fig. 8) Shift the change lever between the right and left positions to switch easily between IMPACT (rotation and impact) and ROTATION (rotation only), respectively. To bore holes in hard materials such as concrete, stone and tiles, shift the change lever to the right- hand position (as indicated by the

mark). The drill bit operates by the combined actions of impact and rotation. To bore holes in metal, wood and plastic, shift the change lever to the left-hand position (as indicated by the

InFocus DV 18V — NOTE diagram (page 4)
Fig. 7

mark). The drill bit operates by rotational action only, as in the case of a conventional electric drill. CAUTION

Do not use the Impact Drill in the IMPACT function

if the material can be bored by rotation only. Such action will not only reduce drill efficiency, but may also damage the drill tip. Operating the Impact Drill with the change lever

Fig. 5 7. Fixing the side handle (Fig. 6) Attach the side handle to the mounting part. Rotate the side handle grip in a clockwise direction to secure it. Set the side handle to a position that is suited to the operation and then securely tighten the side handle grip.

in mid-position may result in damage. When switching, make sure that you shift the change lever to the correct position.

InFocus DV 18V — NOTE diagram (page 4)
Fig. 8
Show 5 more labels / short text on this page
Retaining ring · Switch trigger · Change lever · Side handle · Loosen Tighten
Page 5 of the InFocus DV 18V user manual — HOW TO USE
Page 5 · click to enlarge
Page 5

9. High-speed/Low-speed changeover: Prior to changing speed, ensure that the switch is in the OFF position, and the drill has come to a complete stop. To change speed, rotate the gear shift dial as indicated by the arrow in Fig. 9. The numeral “1” engraved on the drill body denotes low speed, the numeral “2” denotes high speed. If it is hard to turn the gear shift dial, turn the chuck slightly in either direction and then turn the gear shift dial again.

2. Drilling When drilling, start the drill slowly, and gradually

increasing speed as you drill. Always apply pressure in a straight line with the bit.

Use enough pressure to keep drilling, but do not push hard enough to stall the motor or deflect the bit. To minimize stalling or breaking through the material,

reduce pressure on drill and ease the bit through the last part of the hole. If the drill stalls, release the trigger immediately,

remove the bit from the work and start again. Do not click the trigger on and off in an attempt to start a stalled drill. This can damage the drill. The larger the drill bit diameter, the larger the reactive

InFocus DV 18V — MAINTENANCE AND INSPECTION diagram (page 5)
Fig. 9

force on your arm. Be careful not to lose control of the drill because of this reactive force. To maintain firm control, establish a good foothold, use side handle, hold the drill tightly with both hands, and ensure that the drill is vertical to the material being drilled.

MAINTENANCE AND INSPECTION

1. Inspecting the drill bits Since use of an abraded drill bits will cause motor malfunctioning and degraded efficiency, replace the drill bits with a new one or resharpening without delay when abrasion is noted. 2. Inspecting the mounting screws Regularly inspect all mounting screws and ensure that they are properly tightened. Should any of the screws be loose, retighten them immediately. Failure to do so could result in serious hazard. 3. Maintenance of the motor The motor unit winding is the very “heart” of the power tool. Exercise due care to ensure the winding does not become damaged and/or wet with oil or water. 4. Inspecting the carbon brushes For your continued safety and electrical shock protection, carbon brush inspection and replacement on this tool should ONLY be performed by a Hitachi Authorized Service Center. 5. Replacing supply cord If the supply cord of Tool is damaged, the Tool must be returned to Hitachi Authorized Service Center for the cord to be replaced. 6. Service parts list CAUTION:

HOW TO USE

1. Switch operation When the trigger is depressed, the tool rotates. When

the trigger is released, the tool stops. The rotational speed of the drill can be controlled by

varying the amount that the trigger switch is pulled. Speed is low when the trigger switch is pulled slightly and increases as the trigger switch is pulled more. The desired rotation speed can be pre-selected with

the speed control dial. Turn the speed control dial clockwise for higher speed and counterclockwise for lower speed. (Fig. 10) Pulling the trigger and pushing the stopper, it keeps

the switched-on condition which is convenient for continuous running. When switching off, the stopper can be disconnected by pulling the trigger again. CAUTION

If the L-side of push button is pressed for reverse bit rotation, the stopper cannot be used.

Repair, modification and inspection of Hitachi Power Tools must be carried out by a Hitachi Authorized Service Center. This Parts List will be helpful if presented with the tool to the Hitachi Authorized Service Center when requesting repair or other maintenance. In the operation and maintenance of power tools, the safety regulations and standards prescribed in each country must be observed.

Show 5 more labels / short text on this page
Stopper · Speed control dial · Low speed · High speed · Switch trigger
Page 6 of the InFocus DV 18V user manual — MODIFICATION:
Page 6 · click to enlarge
Page 6

MODIFICATION:

Hitachi Power Tools are constantly being improved and modified to incorporate the latest technological advancements. Accordingly, some parts may be changed without prior notice.

Page 7 of the InFocus DV 18V user manual — 23 981-328 1 24 319-535 1 D3.5
Page 7 · click to enlarge
Page 7

40 322-862 1 41 322-853 1 42 322-854 1 43 321-630 1 100L 44 1 322-517 1 220V-240V 44 2 322-518 1 “GBR (110V)”

45 999-041 2 46 955-203 2 47 1 48 994-273 1 49 992-635 1 50 321-631 1 55L 51 1 321-634 1 110V-240V 51 2 322-519 1 “GBR (110V)”

Item Code No. Remarks No. No. Used

52 984-750 2 D4 × 16

53 937-631 1 54 953-327 1 D8.8

55 1 501 1 502 1 503 303-709 1

2 987-576 1 31 321-814 1 13VLRB-D 32 322-357 1 13VLRH-N 4 322-857 1 5 939-556 1 6 322-851 1 7 620-2DD 1 6202DDCMPS2L 8 322-850 1 9 984-101 1 10 959-150 1 D6.35

29 322-846 1 30 608-DDM 1 608DDC2PS2L 31 939-553 1 32 1 360-654C 1 110V 32 2 360-654E 1 220V-230V 32 3 360-654F 1 240V 33 322-843 1 34 981-824 2 D4×45

35 1 340-589C 1 110V 35 2 340-589E 1 220V-230V 35 3 340-589F 1 240V 36 608-VVM 1 608VVC2PS2L 37 322-861 1 38 1 39 301-653 3 D4×20

Item Code No. Remarks No. No. Used

13 322-852 2 14 322-858 1 15 322-841 1 16 322-842 1 17 322-840 1 18 322-859 1 19 322-847 1 “20-22”

1 995-344 1 M6 × 25

11 322-845 1 12 316-321 4 D5×45

20 1 21 322-848 1 22 306-353 1 S-22

23 981-328 1 24 319-535 1 D3.5

25 322-844 1 “11”

26 1 27 322-849 1 28 322-860 1 D5

InFocus DV 18V — 23 981-328 1 24 319-535 1 D3.5 diagram (page 7)
Fig. 10
Page 8 of the InFocus DV 18V user manual — 52 984-750 2 D4 × 16
Page 8 · click to enlarge
Page 8

Hitachi Koki Co., Ltd.

404 Code No. C99131611 Printed in China

Ask about the InFocus DV 18V

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the InFocus DV 18V

Be the first to ask — other owners or our team will answer.

Original document

InFocus DV 18V manual PDF

8 pages·321 KB·Impact Driver·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…