6 -P or t S A T A R AI D Co ntr oller User G u ide Part number: 377602-003 Third edition: May 2006.
2 Legal notices © Copyright 2004, 2006 Hewlett- Packard Development Company, L.P. The information contained herein is subject to change without notice. The only warranties for HP products and services are set forth in the express warranty statements accompanying such products and servi c es.
Contents 3 Contents 1 Board components and features Controller specificatio ns and attributes ....................................................................................... ................. 4 2 Installation and configuration procedures Overview of the inst allation process .
Board compone nts and features 4 1 Boar d co mponents and f eatur es Figure 1-1 6-Port SATA RAID Controller 1 Internal SATA port 0 3 Flash jumper 2 Internal SATA port 5 4 I2C connector C ontr oller sp.
Installation and config uration procedures 5 2 Inst allati on and co nf i gur ation pr ocedur e s Ov erv i e w of the ins tallati on pr ocess 1. Install and configure the controller and hard drives. Fo r details, see “Installing the controller and drives” on page 5.
Installation and config uration procedures 6 7. Attach the other end of the I2C able to the connector on the internal drive cage backplane board (2). Figure 2-1 8. Install drives in the internal SATA dr ive bay of the server, if necessary. The 6-Port SATA RAID Controller can support logical drives of up to 2 TB capacity.
Installation and config uration procedures 7 Assi gning the boot contr oller NOTE: If the server will contain two or more bootable controllers, read this section. Otherwise, omit this section. The 6-Port SATA RAID controller supports bootable drives and arrays.
Installation and config uration procedures 8 13. On the next screen, respond as follows: Table 2-1 Entries for array properties Property line disp layed Entry or selection Array type Select the RAID level, and the press the Enter key. Array label Type a name, and then press the Enter key.
Appendix A: Electrostati c discharge 9 Appe ndi x A: Electr os tati c dis c har ge Pr e ven ting elec tr o s tati c dis c har ge To prevent damaging the system, be aw are of the precautions you must follo w when setting up the system or handling parts.
Appendix B: Regulatory compliance notices 10 Appe ndi x B: R egulato r y compliance n oti ce s F eder al C omm uni cati ons C ommis si on noti ce Part 15 of the Federal Communications Commission (FCC) Rules and Regulations has established Radio Frequency (RF) emission limits to prov ide an interference-free r adio frequency spectrum.
Appendix B: Regulatory compliance notices 11 For questions regarding this FCC declaratio n, contact us by mail or telephone: • Hewlett-Packard Company P. O. Box 692000, Ma il Stop 510101 Houston, Texas 77269-2000 • 1-281-514-333 3 To identify this product, refer to the part, series, or model nu mber found on the product.
Appendix B: Regulatory compliance notices 12 Japanes e noti ce K or ean noti ces Class A Equipment Class B Equipment.
Appe ndix C: Using t he RAI D Confi gura tion U tility 1 3 Appe ndi x C: Using the RAI D Co nf i gur atio n Utility The RAID Configuration Utility is loaded on the controlle r ROM. The utility is used to create, configure, and manage arrays, and make arrays bootable.
Appe ndix C: Using t he RAI D Confi gura tion U tility 1 4 14. Select the method by which you wa nt the array to be created. • Build/Verify conducts a background initialization on the array. The array is available immediately, although performance is degraded.
Appe ndix C: Using t he RAI D Confi gura tion U tility 1 5 4. Press the Enter key. The following message appears: Warning!! Deleting will erase all the data from the array. Do you still want to continue? (Yes/No): 5. Select Yes to delete the array, or No to return to the previous menu.
Appe ndix C: Using t he RAI D Confi gura tion U tility 1 6 Re sc a n n i n g d rive s 1. Restart the computer. 2. When the appropriate prompt appears, press Ctrl+A to access the RAID Configuration Utility. 3. From the RAID Configuration Utility menu, select Array Configuration Utility.
Appendix D: About RAID 17 Appe ndi x D: Abou t RAI D A Redundant Array of Independent Disk (RAID) provides better performance and reliability from combinations of drives than is possible with the same total storage space without RAID. This Appendix describes the various RAID levels supported by the 6-Port SATA RAID controller.
Appendix D: About RAID 18 RAID 1 A RAID 1 array is created by copying, or mirroring, a ll data from one drive onto a second drive. This mirroring provides redundancy, ensuring that if one drive fails no data is lost. Howeve r, redundancy also means that only half the total capacity is available.
Appendix D: About RAID 19 RAID 10 This dual-level RAID type is created by using two or mo re equal-sized RAID 1 arrays to create a RAID 0 array. Both read and write performance are improved becaus e array striping occurs. However, the performance improvement requires that additional storage s pace be used because the arrays are mirrored.
Appendix D: About RAID 20 RAID 50 This dual-level RAID type is created by using two or mo re equal-sized RAID 5 arrays to create a RAID 0 array. The top level RAID 0 array shares the load among the second-level RAID 5 a rrays, improving both read and write performance.
Glossary 2 1 Glo ss ar y activity See task. array A logical disk created from avai lable space a nd made up of one or more partitions on one or more physical disks. Arrays are typically used to provide data redundancy or enhanced I/O performance. See also container , volume , spanned volume , and RAID signature .
Glossary 2 2 degraded A redundant array (for example, a RAID 1 array) in which one or more members have failed. The data is intact, but redundancy has been co mpromised.
Glossary 2 3 impacted An impacted array is one which has been crea ted, but for some reason the initial build operation did not complete. All member driv es are present and operational, and all data written to the array is protected. To opti mize the array, run a Verify with Fix task.
Glossary 2 4 redundant The ability of an array to main tain operability when one or more hardware failures occur. RAID 1 array is an example of a redundant arra y. In the event of a drive failure, redundant arrays can be restored to normal operation by replacing the failed drive and rebuilding the array.
Index 25 Inde x B board components, 4 boot controller, ass igning, 7 bootable a rray, crea ting, 7 BSMI notice, 11 C cables, 11 Canadian notice, 11 controller attribu tes, 4 controller feat ures, 4 co.
An important point after buying a device HP (Hewlett-Packard) 6-Port SATA RAID (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought HP (Hewlett-Packard) 6-Port SATA RAID yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data HP (Hewlett-Packard) 6-Port SATA RAID - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, HP (Hewlett-Packard) 6-Port SATA RAID you will learn all the available features of the product, as well as information on its operation. The information that you get HP (Hewlett-Packard) 6-Port SATA RAID will certainly help you make a decision on the purchase.
If you already are a holder of HP (Hewlett-Packard) 6-Port SATA RAID, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime HP (Hewlett-Packard) 6-Port SATA RAID.
However, one of the most important roles played by the user manual is to help in solving problems with HP (Hewlett-Packard) 6-Port SATA RAID. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device HP (Hewlett-Packard) 6-Port SATA RAID along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center