Instruction/ maintenance manual of the product PP38+ Harman
Go to page of 38
3-90-08422R27_09/12 SA VE THESE INSTRUCTIONS. Installation & Operating Manual “Ce manuel est disponible en Français sur demande” SAFETY NOTICE PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INST ALL AND USE YOUR NEW ROOM HEA TER. F AILURE TO FOLLOW INSTRUCTIONS MA Y RESUL T IN PROPERTY DAMAGE, BODIL Y INJUR Y , OR EVEN DEA TH.
3-90-08422R27_09/12 2 PP38+ Pellet Stove "PREVENT HOUSE FIRES" Install and Use Only in Accordance With Manufacturer's Installation and Operation Instructions. Contact Local Building or Fire Ofcials About Restrictions and Installation Inspection in Y our Area.
3 PP38+ Pellet Stove 3-90-08422R27_09/12 Safety Information 5 Installation 6 V enting 8 ESP Control 15 Operation 16 Draft T est Procedure 19 Maintenance 20 T roubleshooting 25 Specications .
4 PP38+ Pellet Stove 3-90-08422R27_09/12 DO NOT INST ALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT . DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. MOBILE HOME INST ALLA TION SHOULD BE DONE IN ACCORDANCE WITH THE MANUF ACTURED HOME AND SAFETY ST ANDARD (HUD), CFR 3280, P ART 24.
5 PP38+ Pellet Stove 3-90-08422R27_09/12 Assembly and Installation The optional Room Sensor cable attaches to two bare terminals on the rear of the circuit board. These connections are not polarity specic. Unpacking The P38 is bolted (1/4 x 1" hex head bolts) to the skid to prevent movement during shipping.
6 PP38+ Pellet Stove 3-90-08422R27_09/12 Installing Place thestove on anoncombustible type oor oroor protector that extends a minimum of 6 inches (152mm) to the front of the load door opening, 6 inches (152mm) to the sides of the door opening, and 6 inches to the rear .
7 PP38+ Pellet Stove 3-90-08422R27_09/12 V enting Requirements for T erminating the V enting W ARNING: V enting terminals must not be recessed into a wall or siding. NOTE: Only approved pellet vent pipe, wall pass- throughs,andrestops shouldbeusedwhenventing through combustible materials.
8 PP38+ Pellet Stove 3-90-08422R27_09/12 V enting V enting A combustion blower is used to extract the combustion gases from the rebox. This causes a negative pressure in the rebox and a positive pressure in the venting system as shown in Fig.
9 PP38+ Pellet Stove 3-90-08422R27_09/12 Per national building codes, consideration must be given to combustion air supply to all combustion appliances. Failure to supply adequate combustion air for all appliance demands, may lead to back-drafting of those and other appliances.
10 PP38+ Pellet Stove 3-90-08422R27_09/12 #2 Preferred method This method also provides excellent venting for normal operation but requires the stove to be installed farther from the wall. The vertical portion of the vent should be three to ve feet high and at least three inches from a combustible wall.
11 PP38+ Pellet Stove 3-90-08422R27_09/12 #4 Installing into an existing chimney This method provides excellent venting for normal operation. This method also provides natural draft in the event of a power failure. If the chimney condition is questionable* you may want to install a liner as in method #7.
12 PP38+ Pellet Stove 3-90-08422R27_09/12 #6 Installing into an existing replace chimney This method provides excellent venting for normal operation. This method also provides natural draft in the event of a power failure. In some places in the US and Canada it is required that the vent pipe extend all the way to the top of the chimney .
13 PP38+ Pellet Stove 3-90-08422R27_09/12 #8 Installing through the ceiling Through the ceiling vent, follow PL vent manufacturers recommendations when using wall and ceiling pass through.
14 PP38+ Pellet Stove 3-90-08422R27_09/12 ESP CONTROL Status Light Error Messages 3-Blinks: Indicates that the ESP has gone out of range too many times. Could be an indicator of build up of ash,etc. in theue pipe orheat exchange.
15 PP38+ Pellet Stove 3-90-08422R27_09/12 OPERA TION The PP38+ features two operating modes; Stove T emperature Mode and Room T emperature Mode . In Stove T emperature Mode, you select a burn rate and the stove will remain at the same burn rate regardless of the room temperature.
16 PP38+ Pellet Stove 3-90-08422R27_09/12 OPERA TION The setting above will produce continuous maximum heat output with the distribution blower at full speed. Stove T emperature Mode The setting above will produce continuous medium heat output with the distribution blower at low speed.
17 PP38+ Pellet Stove 3-90-08422R27_09/12 Make sure the unit is plugged into a 120 V AC, 60 HZ electrical source. The power light should be the only light lit. 1. T urn FEED ADJUSTER to desired feed rate . No. 4 is good for most pellets. 4 2. T urn the MODE SELECT OR to “OFF” and then to the desired mode.
18 PP38+ Pellet Stove 3-90-08422R27_09/12 A simple draft test should be performed before andaftercompletingtheuepipeinstallation. T o compare and to record the results for future reference: 1. Plug the unit into a 120 V AC, 60 HZ outlet.
19 PP38+ Pellet Stove 3-90-08422R27_09/12 Maintenance Minimizing Creosote: Whenever wood is burned slowly , the potential exists for creosote to form in the venting. The chimney or venting system should be inspected periodically throughout the heating season to determine if a creosote buildup has occurred.
20 PP38+ Pellet Stove 3-90-08422R27_09/12 Maintenance Fig 27 Scraper Blower Cover Latch Blower Wheel Flue Outlet Heat Exchanger Fins Combustion Blower Cover Blower Cover Latch Fig 26 Scraping the burn pot: Whenever adding fuel to the hopper , take the time and scrape the grate surface of the burnpot, using the scrapertool provided.
21 PP38+ Pellet Stove 3-90-08422R27_09/12 Maintenance Exposed blower wheel and ue opening, NOTE: ESP probe is visible. ESP Probe Fig. 30 Fig. 31 Fig. 33 Burn pot Clean-out plate Latch "open "with blower cover partly removed. Burn pot clean-out is open.
22 PP38+ Pellet Stove 3-90-08422R27_09/12 Burn Pot Cleaning and Maintenance 1. Scrape the top holed surface and sides of the burn pot. (Fig 33) It is not necessary to completely remove all material from the burn pot. The excess will be pushed out during the next use.
23 PP38+ Pellet Stove 3-90-08422R27_09/12 Maintenance - Cleaning the Feeder Body Pellet nes may accumulate in the feeder body over a period of time; therefore, a yearly inspection and cleaning of this area must be performed.
24 PP38+ Pellet Stove 3-90-08422R27_09/12 SMOKE IS VISIBLE COMING OUT OF VENT 1. Air-fuel ratio is too rich. A. Feed rate too high. B. Draft too low caused by a gasket leak. LOW HEA T OUTPUT 1. Feed rate too low 2. Draft too low because of gasket leak.
25 PP38+ Pellet Stove 3-90-08422R27_09/12 25 Weight 212 lbs. Blower 135 cfm Feed Rate approximate .75lb. to 5.5 lbs per hr Hopper Capacity 50 lbs Fuel Wood Pellets Flue Size 3 inch Outside Air Size 2 3/8" I.D. inch Fuse Rating 6 amp Specications 32.
26 PP38+ Pellet Stove 3-90-08422R27_09/12 Options Side Heat Shields - Part #1-00-773863 Side heat shields are available to reduce the clearance to combustible materials. Hopper Extension - Part #1-00-08536 The hopper extension allows you to put more pellet fuel in the hopper which extends the burn time on one load of pellets.
3-90-08422R27_09/12 Harman pellet burning, free-standing stoves and inserts have been tested t o ASTM E1509 for burning shelled corn in a mixture with wood pellets.
28 PP38+ Pellet Stove 3-90-08422R27_09/12 28 PP38+ Pellet Stove Fuel Specications Fuel and Fuel Storage Pelletfuelqualitycanuctuatefrommanufacturerto manufacturer , and even from bag to bag.
29 PP38+ Pellet Stove 3-90-08422R27_09/12 29 PP38+ Pellet Stove Wiring Diagram -- -- SP ARE NUMBER -- -- -- -- -- 11-12-2008 -- 1:1 773869 B ---- WEIGHT or LENGTH REV REVISIONS P ART NUMBER BY DA TE TITLE DRAWN BY USED ON MATERIAL FINISH MATL PN .
3-90-08422R27_09/12 30 PP38+ Pellet Stove 4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc. LIMITED LIFETIME W ARRANTY Hearth & Home T echnologies Inc.
4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS: • This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor . A list of HHT authorized dealers is available on the HHT branded websites. • This warranty is only valid while the HHT appliance remains at the site of original installation.
3-90-08422R27_09/12 Service Parts P38 Pellet Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
3-90-08422R27_09/12 Service Parts P38 Pellet Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
3-90-08422R27_09/12 Service Parts P38 Pellet Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active 2.3 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.1 1 2.12 2.1 2.2 #2 Pre Serial Number 00808066 Feeder Assembly IMPORT ANT : THIS IS DA TED INFORMA TION.
3-90-08422R27_09/12 Service Parts P38 Pellet Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
3-90-08422R27_09/12 Service Parts P38 Pellet Beginning Manufacturing Date: N/A Ending Manufacturing Date: Active IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
37 PP38+ Pellet Stove 3-90-08422R27_09/12 Service & Maintenance Log Date Of Service Performed By Description Of Service.
At Harman, we build each pr oduct to a standard, not a price . This pow erful heating appliance boasts uncompr omising attention to detail and helps pr eser ve our planet b y using envir onmentall y responsible fuels.
An important point after buying a device Harman PP38+ (or even before the purchase) is to read its user manual. We should do this for several simple reasons:
If you have not bought Harman PP38+ yet, this is a good time to familiarize yourself with the basic data on the product. First of all view first pages of the manual, you can find above. You should find there the most important technical data Harman PP38+ - thus you can check whether the hardware meets your expectations. When delving into next pages of the user manual, Harman PP38+ you will learn all the available features of the product, as well as information on its operation. The information that you get Harman PP38+ will certainly help you make a decision on the purchase.
If you already are a holder of Harman PP38+, but have not read the manual yet, you should do it for the reasons described above. You will learn then if you properly used the available features, and whether you have not made any mistakes, which can shorten the lifetime Harman PP38+.
However, one of the most important roles played by the user manual is to help in solving problems with Harman PP38+. Almost always you will find there Troubleshooting, which are the most frequently occurring failures and malfunctions of the device Harman PP38+ along with tips on how to solve them. Even if you fail to solve the problem, the manual will show you a further procedure – contact to the customer service center or the nearest service center