3:1 Fire–Ball 425 Pump

For pumping non–corrosive and non–abrasive oils and lubricants.
540 psi (3.7 MPa, 37 bar) Maximum Working Pressure
180 psi (1.2 MPa, 12 bar) Maximum Air Input Pressure
Warnings 2 Installation 5 Operation 8 Troubleshooting Guide 9 Air Motor and Throat Service 10 Displacement Pump Service 13 Air Motor Parts Drawing 14 Air Motor Parts List 15 Displacement Pump Parts Drawing and List 16 Dimensions 17 Technical Data 18 Performance Data 19 Warranty 20

Caution Symbol
WARNING
CAUTION
This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.
This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.
Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
This equipment is for professional use only.
Read all instruction manuals, tags, and labels before operating the equipment.
Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor.
Do not alter or modify this equipment.
Check equipment daily. Repair or replace worn or damaged parts immediately.
Do not exceed the maximum working pressure stated on the equipment or in the Technical Data section of the instruction manual for your equipment. Do not exceed the maximum working pressure of the lowest rated component in your system.
Use fluids and solvents that are compatible with the equipment wetted parts. Refer to the Technical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.
Do not use 1,1,1–trichloroethane, methylene chloride, other halogenated hydrocarbon solvents, or fluids containing such solvents in pressurized aluminum equipment. Such use could result in a chemical reaction, with the possibility of explosion.
Handle hoses carefully. Do not pull on hoses to move equipment.
Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 82 C (180 F) or below –40 C (–40 F).
Do not lift pressurized equipment.
Comply with all applicable local, state, and national fire, electrical, and safety regulations.

Fluid from the dispensing valve, leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury.
Fluid injected into the skin may look like just a cut, but it is a serious injury. Get immediate surgical treatment.
Do not point the dispensing valve at anyone or at any part of the body.
Do not put your hand or fingers over the end of the dispensing valve.
Do not stop or deflect leaks with your hand, body, glove, or rag.
Use only extensions and no-drip tips that are designed for use with your dispensing valve.
Do not use a low-pressure flexible nozzle with this equipment.
Follow the Pressure Relief Procedure on page 8 if the dispensing valve clogs and before cleaning, checking, or servicing the equipment.
Tighten all fluid connections before operating the equipment.
Check the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. Do not repair high pressure couplings; you must replace the entire hose.
Fluid hoses must have spring guards on both ends to help protect them from rupture caused by kinks or bends near the couplings.
Improper handling of hazardous fluids or inhaling toxic fumes can cause extremely serious injury or death from splashing in the eyes, ingestion, or bodily contamination.
Know the specific hazards of the fluid you are using.
Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state, and national guidelines.
Always wear protective eyewear, gloves, clothing, and respirator as recommended by the fluid and solvent manufacturer.

Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.
Ground the equipment and the object being lubricated. Refer to Grounding on page 7.
If there is any static sparking or you feel an electric shock while using this equipment, stop dispensing immediately. Do not use the equipment until you identify and correct the problem.
Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being dispensed.
Keep the dispensing area free of debris, including solvent, rags, and gasoline.
Before operating this equipment, electrically disconnect all equipment in the dispensing area.
Before operating this equipment, extinguish all open flames or pilot lights in the dispensing area.
Do not smoke in the dispensing area.
Do not turn on or off any light switch in the dispensing area while dispensing or while there are any fumes in the air.
Do not operate a gasoline engine in the dispensing area.
Moving parts, such as the air motor piston, can pinch or amputate your fingers.
Keep clear of all moving parts when starting or operating the pump.
Before servicing the equipment, follow the Pressure Relief Procedure on page 8 to prevent the equipment from starting unexpectedly.

The typical installation shown in Fig. 1 is only a guide for selecting and installing a pump; it is not an actual system design. Contact your Graco representative for assistance in designing a system to suit your needs.
D N A C A
E
P J
R
B
Y
K
H
DETAIL A
S
M
KEY
A Bleed-type master air valve (required) B Air line filter C Air regulator and gauge D Pump runaway valve (shown for position) not needed if you use a low-level cut-off valve E Air Inlet G Pump (Model 237526 shown) H Fluid drain valve (required)
J Dispensing valve (Model 222411 shown) K Thermal relief kit (required) 237601 L Male quick-disconnect fitting M Female quick-disconnect coupler N Air line lubricator P Fluid hose S Fluid inlet, 1 1/2” npt R Electrically conductive air hose (218093 shown) Y Ground wire (required)
For portable applications · ·

Install the following accessories in the order shown in Fig.1:
Install an air line lubricator (N) for automatic air motor lubrication.
Do not hang the air accessories directly on the air inlet (E). The fittings are not strong enough to support the accessories and may cause one or more to break. Provide a bracket on which to mount the accessories.
Install a bleed-type master air valve (A) to relieve air trapped between it and the motor when the valve is closed. As an alternative, you can install an air line quick disconnect coupler (M) and fitting (L) to serve as an air-bleed device. See Detail A in Fig.1. To order a 1/2” npt, 300 psi (2.1 MPa, 21 bar) Maximum Working Pressure bleed-type master air valve, order Part No. 107142.
Three accessories are required in your system: an air bleed device, a fluid drain valve, and a thermal relief kit. These accessories help reduce the risk of serious bodily injury including fluid injection, splashing in the eyes or on the skin, and injury from moving parts if you are adjusting or repairing the pump.
Install the air regulator (C) to control pump speed and pressure.
Install an air line filter (B) to remove harmful dirt and contaminants from your compressed air supply. Install another bleed-type master air valve (A) to isolate the accessories for servicing.
The air bleed device relieves air trapped between it and the air motor after the air supply is shut off. Trapped air can cause the air motor to cycle unex- pectedly, causing serious bodily injury if you are adjusting or repairing the pump. Use either a bleed-type master air valve (A) or a quick discon- nect coupler (M) and fitting (L). Install it near the pump air inlet, within easy reach of the pump.
Install a fluid drain valve (H) near the pump fluid outlet to relieve fluid pressure in the hose and gun when the valve is opened. To order a 3/8” npt (mbe) fluid drain valve, order Part No. 210658.
Install a suitable fluid hose (P) and dispensing valve (J).
The fluid drain valve (H) assists in relieving fluid pressure in the displacement pump, hoses and dispensing valve. Triggering the valve to relieve pressure may not be sufficient.
Install a thermal relief kit (K) to relieve pressure in the fluid line caused by heat expansion. To order a 600 psi (4.1 MPa, 41 bar) minimum relief pressure, 630 psi (4.4 MPa, 44 bar) maximum relief pressure thermal relief kit, order Part No. 237601.
The thermal relief kit (K) relieves pressure in the fluid line caused by heat expansion.

To ground the pump, remove the ground screw (Z) and insert through the eye of the ring terminal at end of the ground wire (Y). Fasten the ground screw back onto the pump and tighten securely. Connect the other end of the ground wire to a true earth ground. See Fig. 2. To order a ground wire and clamp, order Part No. 222011.
Proper grounding is an essential part of maintaining a safe system.
To reduce the risk of static sparking, ground the pump. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Be sure to ground all of the following equipment:
Pump: Use a ground wire and clamp as shown to the right.
Air and Fluid hoses: Use only electrically conductive hoses.
Air compressor: Follow manufacturer’s recommendations.
Fluid supply container: According to local code.
To maintain grounding continuity when flushing or relieving pressure, always hold a metal part of the valve firmly to the side of a grounded metal pail, then trigger the valve.

SKIN INJECTION HAZARD To reduce the risk of serious bodily injury, including fluid injection or splash- ing in the eyes or on the skin, always follow this procedure whenever you shut off the pump, when checking or servicing any part of the system, when installing or changing dispensing devices, and whenever you stop dispensing.
air supplied, the pump starts when the dis- pensing valve is opened and shuts off when it is closed.
COMPONENT RUPTURE HAZARD The maximum working pressure of each component in the system may not be the same. To reduce the risk of overpres- surizing any component in the system, be sure you know the maximum working pressure of each component. Never exceed the maximum working pressure of the lowest rated component in the system. Overpressurizing any component can result in rupture, fire, explosion, property damage, and serious injury.
Never allow the pump to run dry of the fluid being pumped. A dry pump will quickly accelerate to a high speed, possibly damaging itself. If your pump accelerates quickly, or is running too fast, stop it immediately and check the fluid supply. If the supply container is empty and air has been pumped into the lines, prime the pump and lines with fluid, or flush it and leave it filled with a compatible sol- vent. Be sure to eliminate all air from the fluid lines.
To determine the fluid output pressure using the air regulator reading, multiply the ratio of the pump by the air pressure shown on the regulator gauge. For example:
3 (:1) ratio x 180 psi air = 540 psi fluid output
Read and follow the instructions supplied with each component in your system.
[3 (:1) ratio x 1.2 MPa air = 3.6 MPa fluid output]
[3 (:1) ratio x 12 bar air = 36 bar fluid output]
If the pump will be unattended for any period of time, or to shut off the system at the end of the work shift, always follow the Pressure Relief Procedure at left.
Limit the air to the pump so that no air line or fluid line component or accessory is overpressurized.

solutions before disassembling the pump.
INJECTION HAZARD To reduce the risk of serious bodily injury, including fluid injection or splash- ing in the eyes or on the skin, always follow the Pressure Relief Procedure on page 8 whenever you shut off the pump, when checking or servicing any part of the system, when installing or changing dispensing devices, and whenever you stop dispensing.
* Follow the Pressure Relief Procedure on page 8, and disconnect the fluid line. If the pump starts when the air is turned on again, the line, hose, valve, etc., is clogged.

Be sure you have all necessary parts on hand. Air Motor Repair Kit 207385 includes repair parts for the motor. Use all the parts in the kit for the best results. Parts included in the kit are marked with one asterisk, for example (19*), in the text and drawings. See the Parts List on page15.

To avoid damaging the cylinder wall, lift the cylinder straight up off of the piston. Never tilt the cylinder as it is being removed.
Two accessory tools should be used: Padded Pliers, 207579, are used to grip the trip rod without damaging its surface, and a 0.125-in. (3.18 mm) Gauge, 171818, is used to assure the proper clearance between the poppets and seat of the piston.


Do not damage the plated surface of the trip rod (31). Damaging the surface of the trip rod can result in erratic air motor operation. Use the special padded pliers, 207579, to grasp the rod.
Included in Repair Kit 237602.

14. In this step, while you are prying with the screw- driver with one hand, cover the toggle assemblies with your other hand so as to catch the spring- loaded toggle assemblies when they snap out of the lugs. Place the tip of a screwdriver into the piston between the piston lugs (L) below the pivot pins (16) on the toggles, pry up with the screw- driver handle to compress the springs on the toggle assembly (M) up and away from the piston lugs, and remove the parts. See Fig. 4.
MOVING PARTS HAZARD To reduce the risk of pinching or amputating your fingers, keep your fingers clear of the toggle assemblies when you are snapping the toggles (M in Fig. 4 ) up or down.


Cut off tops of poppets as indicated by dotted lines.
Turn lock- wire s up.
poppets and the piston seat by turning the top valve nuts (21*).
onto the poppets, they will run off of the threaded part of the poppets.
Never re-use the old lock wires. They get brittle and will break easily from too much bending.

(107) face up. See Fig. 3.
includes repair parts for the pump throat and piston. Use all the parts in the kit for the best results. Parts included in the kit are marked with a dagger, for example (7), in the text and drawings. See the Parts List on page 16.
Do steps 14 through 21 in Air Motor and Throat Service on this page.
Intake Valve See Fig 5.
110 107 112
Displacement Pump See Fig 5.
as you disassemble them. Replace parts as needed. For best results, always replace all the o-rings and packings when you disassem- ble the pump.
Included in Repair Kit 237602.



Ref. No. Part No. Description Qty.
Ref. No. Part No. Description Qty.
3 101578 SCREW, cap, hex hd 8 5 102656 MUFFLER, air exhaust 1 7 116343 SCREW, grounding 1 10 112130 SEAL, pump 1 11 156698 PACKING, o-ring 1 12 158359 ACTUATOR, valve, air 2 13 158360 YOKE, rod, trip 1 15 158362 PIN, toggle 2 16 158364 PIN, pivot 2 17* 158367 GROMMET, inlet valve 2 18 158377 PACKING, ring, seal 1 19* 158378 PACKING, o-ring 1 20* 158379 PACKING, o-ring 1 21* 160261 NUT, valve 4 22* 160618 WIRE, lock 2 23 160623 ARM, toggle 2 24 190929 LIFT RING 1
25 167585 SPRING, helical compression 2 26* 170709 POPPET, exhaust valve 2 27 207391 PISTON, includes items 27a to 27c (also includes 207385 repair kit when ordered as a replacement part) 1 27a 102975 SCREW, rd hd mach; 6–32 x 1/4” 2 27b 158361 CLIP, Spring 2 27c BARE PISTON (not sold separately) 1 28 190229 BASE, motor, air 1 29 190233 ROD, piston 1 30 15E954 CYLINDER, motor, air 1 31 207150 ROD, trip 1 32* 236079 POPPET, inlet valve 2 33 119344 LABEL, designation 1 35 290259 LABEL, warning 1
* Included in Air Motor Repair Kit 207385, which may be purchased separately.
Included in Pump Repair Kit 237602, which may be purchased separately.
Extra warning labels are available at no cost.

Ref No. Part No. Description Qty.
Ref No. Part No. Description Qty.
10 112130 SEAL, block, vee shown on page 14 1 101 AIR MOTOR See parts on page 14 1 103 101178 BALL, piston; metallic 1 104 108001 BALL; sst 1 105 110828 PACKING, o-ring 1 107 112565 PACKING, u-cup 1 108 166071 PACKING, o-ring 1
109 189707 PISTON/SEAT, valve 1 110 189708 CYLINDER, pump 1 111 189709 VALVE HOUSING, 1 1/2” npt(f) 1 112 189710 RETAINER, ball 1 113 189711 WASHER, piston 1
These parts are included in Pump Repair Kit 237602, which may be purchased separately.
Lips face up

MODEL 237526 Series B
3/4-in. npt(f) fluid outlet
1/2-in. npt(f) air inlet
3/4-in. npt(f) muffler port
29.4 in. (747 mm)
11.0 in. (279 mm)
1 1/2-in. npt(f) fluid intake
grounding screw · ·

4.12 in. (104.6 mm) diam- eter clearance hole 45
Four 0.406-in. (10.3 mm) holes on 7-in. (177.8 mm) bolt circle
8.0 in. (203.2 mm) diameter of
Maximum working pressure 540 psi (3.7 MPa, 37 bar) Fluid pressure ratio 3:1 Air operating range 40 to 180 psi (0.28 to 1.2 MPa, 2.8 to 12 bar) Air consumption 3 ft3/min per gallon pumped,
(0.022 m3/min per liter pumped) up to 8 ft3/min (0.058 m3/min) with pump
operating within recommended range Pump cycles per gallon (per liter) 6 (1.6) Maximum recommended pump speed 66 cycles/min;
12 gpm (45 lpm) Recommended speed for optimum pump life 15 to 25 cycles per min Piston seals polyurethane Rod seals nitrile Wetted parts aluminum, steel, nitrile Approximate weight 46 lb (21 kg) * Sound pressure 82 dB(A)
* Sound pressure reading taken with pump operating at 60 cycles per minute at 100 psi (0.7 MPa, 7 bar). Sound pressure measured per CAGI-PNEUROP, 1971.
flange ·

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub- stitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais- sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
TO PLACE AN ORDER, contact your Graco distributor, or call one of the following numbers
to identify the distributor closest to you:
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
This manual contains English. MM 308485
www.graco.com 308485 01/1995, Revised 3/2007
1–800–533–9655 Toll Free · 612–623–6928 612–378–3590 Fax ·
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Pump fails to operate | Inadequate air supply pressure or restricted air lines | Increase air supply; clear | p.9 |
| Pump fails to operate | Closed or clogged dispensing valve | Open; clean | p.9 |
| Pump fails to operate | Clogged fluid lines, hoses, valves, etc. | Clear* | p.9 |
| Pump fails to operate | Damaged air motor | Service air motor | p.9 |
| Pump fails to operate | Exhausted fluid supply | Refill and reprime or flush | p.9 |
| Continuous air exhaust | Worn or damaged air motor gas- ket, packing, seal, etc. | Service air motor | p.9 |
| Erratic pump operation | Exhausted fluid supply | Refill and reprime or flush | p.9 |
| Erratic pump operation | Held open or worn intake valve or piston packings | Clear; service | p.9 |
| Pump operates, but output low on up stroke | Held open piston valve or worn piston packings | Clear; service | p.9 |
| Pump operates, but output low on down stroke | Held open or worn intake valve | Clear; service | p.9 |
| Pump operates, but output low on both strokes | Inadequate air supply pressure or restricted air lines | Increase air supply; clear | p.9 |
| Pump operates, but output low on both strokes | Closed or clogged valves | Open; clean | p.9 |
Owners and our team usually reply within a day — and your question helps the next person too.