EN
Graco logo
Official user manual

Graco Series B

20 pages·338 KB·Marine Sanitation System·PDF·ENDEFRITNLJA
Graco Series B
Table of Contents 1 sections Parts ShowHide
Page 1 of the Graco Series B user manual — Table of Contents
Page 1 · click to enlarge
Page 1

Instructions – Parts List

3:1 Fire–Ball 425 Pump

Graco Series B — Instructions – Parts List diagram (page 1)
Fig. 1 · Instructions – Parts List

308485N

For pumping non–corrosive and non–abrasive oils and lubricants.

Model 237526, Series B

540 psi (3.7 MPa, 37 bar) Maximum Working Pressure

180 psi (1.2 MPa, 12 bar) Maximum Air Input Pressure

Table of Contents

Warnings 2 Installation 5 Operation 8 Troubleshooting Guide 9 Air Motor and Throat Service 10 Displacement Pump Service 13 Air Motor Parts Drawing 14 Air Motor Parts List 15 Displacement Pump Parts Drawing and List 16 Dimensions 17 Technical Data 18 Performance Data 19 Warranty 20

Page 2 of the Graco Series B user manual — EQUIPMENT MISUSE HAZARD
Page 2 · click to enlarge
Page 2

Symbols

Warning Symbol

Caution Symbol

WARNING

CAUTION

This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.

This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.

WARNING WARNING

EQUIPMENT MISUSE HAZARD

Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.

This equipment is for professional use only.

Read all instruction manuals, tags, and labels before operating the equipment.

Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor.

Do not alter or modify this equipment.

Check equipment daily. Repair or replace worn or damaged parts immediately.

Do not exceed the maximum working pressure stated on the equipment or in the Technical Data section of the instruction manual for your equipment. Do not exceed the maximum working pressure of the lowest rated component in your system.

Use fluids and solvents that are compatible with the equipment wetted parts. Refer to the Technical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.

Do not use 1,1,1–trichloroethane, methylene chloride, other halogenated hydrocarbon solvents, or fluids containing such solvents in pressurized aluminum equipment. Such use could result in a chemical reaction, with the possibility of explosion.

Handle hoses carefully. Do not pull on hoses to move equipment.

Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 82 C (180 F) or below –40 C (–40 F).

Do not lift pressurized equipment.

Comply with all applicable local, state, and national fire, electrical, and safety regulations.

Page 3 of the Graco Series B user manual — HAZARDOUS FLUIDS
Page 3 · click to enlarge
Page 3

WARNING WARNING

SKIN INJECTION HAZARD

Fluid from the dispensing valve, leaks, or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury.

Fluid injected into the skin may look like just a cut, but it is a serious injury. Get immediate surgical treatment.

Do not point the dispensing valve at anyone or at any part of the body.

Do not put your hand or fingers over the end of the dispensing valve.

Do not stop or deflect leaks with your hand, body, glove, or rag.

Use only extensions and no-drip tips that are designed for use with your dispensing valve.

Do not use a low-pressure flexible nozzle with this equipment.

Follow the Pressure Relief Procedure on page 8 if the dispensing valve clogs and before cleaning, checking, or servicing the equipment.

Tighten all fluid connections before operating the equipment.

Check the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. Do not repair high pressure couplings; you must replace the entire hose.

Fluid hoses must have spring guards on both ends to help protect them from rupture caused by kinks or bends near the couplings.

HAZARDOUS FLUIDS

Improper handling of hazardous fluids or inhaling toxic fumes can cause extremely serious injury or death from splashing in the eyes, ingestion, or bodily contamination.

Know the specific hazards of the fluid you are using.

Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state, and national guidelines.

Always wear protective eyewear, gloves, clothing, and respirator as recommended by the fluid and solvent manufacturer.

Page 4 of the Graco Series B user manual — MOVING PARTS HAZARD
Page 4 · click to enlarge
Page 4

WARNING WARNING

FIRE AND EXPLOSION HAZARD

Improper grounding, poor ventilation, open flames, or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.

Ground the equipment and the object being lubricated. Refer to Grounding on page 7.

If there is any static sparking or you feel an electric shock while using this equipment, stop dispensing immediately. Do not use the equipment until you identify and correct the problem.

Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being dispensed.

Keep the dispensing area free of debris, including solvent, rags, and gasoline.

Before operating this equipment, electrically disconnect all equipment in the dispensing area.

Before operating this equipment, extinguish all open flames or pilot lights in the dispensing area.

Do not smoke in the dispensing area.

Do not turn on or off any light switch in the dispensing area while dispensing or while there are any fumes in the air.

Do not operate a gasoline engine in the dispensing area.

MOVING PARTS HAZARD

Moving parts, such as the air motor piston, can pinch or amputate your fingers.

Keep clear of all moving parts when starting or operating the pump.

Before servicing the equipment, follow the Pressure Relief Procedure on page 8 to prevent the equipment from starting unexpectedly.

Page 5 of the Graco Series B user manual — G
Page 5 · click to enlarge
Page 5

Installation

The typical installation shown in Fig. 1 is only a guide for selecting and installing a pump; it is not an actual system design. Contact your Graco representative for assistance in designing a system to suit your needs.

G

D N A C A

E

P J

R

B

Y

K

H

DETAIL A

S

M

KEY

A Bleed-type master air valve (required) B Air line filter C Air regulator and gauge D Pump runaway valve (shown for position) not needed if you use a low-level cut-off valve E Air Inlet G Pump (Model 237526 shown) H Fluid drain valve (required)

J Dispensing valve (Model 222411 shown) K Thermal relief kit (required) 237601 L Male quick-disconnect fitting M Female quick-disconnect coupler N Air line lubricator P Fluid hose S Fluid inlet, 1 1/2” npt R Electrically conductive air hose (218093 shown) Y Ground wire (required)

For portable applications · ·

Page 6 of the Graco Series B user manual — WARNING
Page 6 · click to enlarge
Page 6

Installation

System Accessories

Install the following accessories in the order shown in Fig.1:

CAUTION

Install an air line lubricator (N) for automatic air motor lubrication.

Do not hang the air accessories directly on the air inlet (E). The fittings are not strong enough to support the accessories and may cause one or more to break. Provide a bracket on which to mount the accessories.

Install a bleed-type master air valve (A) to relieve air trapped between it and the motor when the valve is closed. As an alternative, you can install an air line quick disconnect coupler (M) and fitting (L) to serve as an air-bleed device. See Detail A in Fig.1. To order a 1/2” npt, 300 psi (2.1 MPa, 21 bar) Maximum Working Pressure bleed-type master air valve, order Part No. 107142.

WARNING

Three accessories are required in your system: an air bleed device, a fluid drain valve, and a thermal relief kit. These accessories help reduce the risk of serious bodily injury including fluid injection, splashing in the eyes or on the skin, and injury from moving parts if you are adjusting or repairing the pump.

Install the air regulator (C) to control pump speed and pressure.

Install an air line filter (B) to remove harmful dirt and contaminants from your compressed air supply. Install another bleed-type master air valve (A) to isolate the accessories for servicing.

The air bleed device relieves air trapped between it and the air motor after the air supply is shut off. Trapped air can cause the air motor to cycle unex- pectedly, causing serious bodily injury if you are adjusting or repairing the pump. Use either a bleed-type master air valve (A) or a quick discon- nect coupler (M) and fitting (L). Install it near the pump air inlet, within easy reach of the pump.

Install a fluid drain valve (H) near the pump fluid outlet to relieve fluid pressure in the hose and gun when the valve is opened. To order a 3/8” npt (mbe) fluid drain valve, order Part No. 210658.

Install a suitable fluid hose (P) and dispensing valve (J).

The fluid drain valve (H) assists in relieving fluid pressure in the displacement pump, hoses and dispensing valve. Triggering the valve to relieve pressure may not be sufficient.

Install a thermal relief kit (K) to relieve pressure in the fluid line caused by heat expansion. To order a 600 psi (4.1 MPa, 41 bar) minimum relief pressure, 630 psi (4.4 MPa, 44 bar) maximum relief pressure thermal relief kit, order Part No. 237601.

The thermal relief kit (K) relieves pressure in the fluid line caused by heat expansion.

Page 7 of the Graco Series B user manual — TI1052
Page 7 · click to enlarge
Page 7

Installation

Grounding

To ground the pump, remove the ground screw (Z) and insert through the eye of the ring terminal at end of the ground wire (Y). Fasten the ground screw back onto the pump and tighten securely. Connect the other end of the ground wire to a true earth ground. See Fig. 2. To order a ground wire and clamp, order Part No. 222011.

Proper grounding is an essential part of maintaining a safe system.

To reduce the risk of static sparking, ground the pump. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Be sure to ground all of the following equipment:

Pump: Use a ground wire and clamp as shown to the right.

Air and Fluid hoses: Use only electrically conductive hoses.

Air compressor: Follow manufacturer’s recommendations.

Y

Fluid supply container: According to local code.

Z

To maintain grounding continuity when flushing or relieving pressure, always hold a metal part of the valve firmly to the side of a grounded metal pail, then trigger the valve.

TI1052

Page 8 of the Graco Series B user manual — NOTES:
Page 8 · click to enlarge
Page 8

Operation

Pressure Relief Procedure

1. With the air regulator (C) closed, open the bleedtype master air valves (A), or, if so equipped, join the quick disconnect coupler (M) to the male fitting (L).

WARNING

SKIN INJECTION HAZARD To reduce the risk of serious bodily injury, including fluid injection or splash- ing in the eyes or on the skin, always follow this procedure whenever you shut off the pump, when checking or servicing any part of the system, when installing or changing dispensing devices, and whenever you stop dispensing.

2. Open the dispensing valve (J) into a grounded metal waste container, making firm metal-to-metal contact between the container and valve.
3. Open the pump air regulator (C) slowly, just until the pump is running. When the pump is primed and all air has been pushed out of the lines, close the dispensing valve.
1. Close the pump air regulator and the bleed-type master air valve (required in your system).
2. Hold a metal part of the dispensing valve firmly to a grounded metal waste container and trigger the valve to relieve the fluid pressure, or open the drain valve (H).

air supplied, the pump starts when the dis- pensing valve is opened and shuts off when it is closed.

Startup and Adjustment

4. Adjust the air regulator until you get sufficient flow from the dispensing valve. Always run the pump at the lowest speed necessary to get the desired results. Do not exceed the maximum working pressure of any component in the system.

WARNING

COMPONENT RUPTURE HAZARD The maximum working pressure of each component in the system may not be the same. To reduce the risk of overpres- surizing any component in the system, be sure you know the maximum working pressure of each component. Never exceed the maximum working pressure of the lowest rated component in the system. Overpressurizing any component can result in rupture, fire, explosion, property damage, and serious injury.

NOTES:

Never allow the pump to run dry of the fluid being pumped. A dry pump will quickly accelerate to a high speed, possibly damaging itself. If your pump accelerates quickly, or is running too fast, stop it immediately and check the fluid supply. If the supply container is empty and air has been pumped into the lines, prime the pump and lines with fluid, or flush it and leave it filled with a compatible sol- vent. Be sure to eliminate all air from the fluid lines.

To determine the fluid output pressure using the air regulator reading, multiply the ratio of the pump by the air pressure shown on the regulator gauge. For example:

3 (:1) ratio x 180 psi air = 540 psi fluid output

Read and follow the instructions supplied with each component in your system.

[3 (:1) ratio x 1.2 MPa air = 3.6 MPa fluid output]

[3 (:1) ratio x 12 bar air = 36 bar fluid output]

If the pump will be unattended for any period of time, or to shut off the system at the end of the work shift, always follow the Pressure Relief Procedure at left.

Limit the air to the pump so that no air line or fluid line component or accessory is overpressurized.

Page 9 of the Graco Series B user manual — WARNING
Page 9 · click to enlarge
Page 9

Troubleshooting

WARNING

solutions before disassembling the pump.

INJECTION HAZARD To reduce the risk of serious bodily injury, including fluid injection or splash- ing in the eyes or on the skin, always follow the Pressure Relief Procedure on page 8 whenever you shut off the pump, when checking or servicing any part of the system, when installing or changing dispensing devices, and whenever you stop dispensing.

ProblemCauseSolution Pump fails to operateInadequate air supply pressure or restricted air linesIncrease air supply; clear Closed or clogged dispensing valveOpen; clean Clogged fluid lines, hoses, valves, etc.Clear* Damaged air motorService air motor Exhausted fluid supplyRefill and reprime or flush Continuous air exhaustWorn or damaged air motor gasket, packing, seal, etc.Service air motor Erratic pump operationExhausted fluid supplyRefill and reprime or flush Held open or worn intake valve or piston packingsClear; service Pump operates, but output low on up strokeHeld open piston valve or worn piston packingsClear; service Pump operates, but output low on down strokeHeld open or worn intake valveClear; service Pump operates, but output low on both strokesInadequate air supply pressure or restricted air linesIncrease air supply; clear Closed or clogged valvesOpen; clean

* Follow the Pressure Relief Procedure on page 8, and disconnect the fluid line. If the pump starts when the air is turned on again, the line, hose, valve, etc., is clogged.

Page 10 of the Graco Series B user manual — Disassembly
Page 10 · click to enlarge
Page 10

Air Motor and Throat Service

Before You Start

8. Remove the six screws (3) holding the cylinder (30) to the base (28). Carefully pull the cylinder straight up off of the piston (53).

Be sure you have all necessary parts on hand. Air Motor Repair Kit 207385 includes repair parts for the motor. Use all the parts in the kit for the best results. Parts included in the kit are marked with one asterisk, for example (19*), in the text and drawings. See the Parts List on page15.

Graco Series B — Before You Start diagram (page 10)
Fig. 2 · Before You Start

To avoid damaging the cylinder wall, lift the cylinder straight up off of the piston. Never tilt the cylinder as it is being removed.

Two accessory tools should be used: Padded Pliers, 207579, are used to grip the trip rod without damaging its surface, and a 0.125-in. (3.18 mm) Gauge, 171818, is used to assure the proper clearance between the poppets and seat of the piston.

9. Remove the piston/base from the vise, and set it upright on the workbench.
Graco Series B — Before You Start diagram (page 10)
Fig. 3 · Before You Start

Disassembly

1. Flush the pump. Follow the Pressure Relief Procedure on page 8 before proceeding.
2. Disconnect the hoses, remove the pump from its mounting, and clamp the air motor base (28) in a vise horizontally by closing the vice jaws on the flange.
3. Use a strap wrench on the displacement pump cylinder (110) to screw it out of the air motor base (28). See Fig. 3.
4. Remove the air motor base from the vice, and place the piston rod (29) flats in the vice with the air motor up.
5. Loosen the lift ring (24). Pull the lift ring up, grip the trip rod (31) with the padded pliers, and screw the lift ring off of the rod.
6. Remove the piston/valve seat (109) from the rod (29) with wrenches or with the vice and a wrench.
7. Remove the piston ball (103), u-cup packing (107 ), and piston washer (113).
Graco Series B — Disassembly diagram (page 10)
Fig. 4 · Disassembly

Do not damage the plated surface of the trip rod (31). Damaging the surface of the trip rod can result in erratic air motor operation. Use the special padded pliers, 207579, to grasp the rod.

Included in Repair Kit 237602.

Show 6 more labels / short text on this page
19* · 20* · 10 · 113 107 · flange ·
Page 11 of the Graco Series B user manual — WARNING
Page 11 · click to enlarge
Page 11

Air Motor and Throat Service

10. Pull the piston assembly from the air motor base (28), and set it aside.

14. In this step, while you are prying with the screw- driver with one hand, cover the toggle assemblies with your other hand so as to catch the spring- loaded toggle assemblies when they snap out of the lugs. Place the tip of a screwdriver into the piston between the piston lugs (L) below the pivot pins (16) on the toggles, pry up with the screw- driver handle to compress the springs on the toggle assembly (M) up and away from the piston lugs, and remove the parts. See Fig. 4.

11. Remove the vee block seal (10 ) with a pick, and clean the groove in the air motor base (28). Remove any dirt in the groove, and wipe the groove clean with a cloth.
12. Inspect the air motor for damaged or worn inlet valve grommets (17*), o-ring packings (19*, 20*), valve nuts (21*), lock wires (22*), exhaust valve poppets (26*), or inlet valve poppets (32*). If any of these parts need to be replaced, continue with steps 13 to 19. Otherwise, see Reassembly on page 12.
15. Straighten the lockwires (22*) and remove them from the valve nuts (21*). Screw the top nuts off. Remove the trip rod yoke (13), actuator (12), and trip rod (31). Unscrew the bottom nuts (21*), and remove the poppets. Make sure the valve bar spring clips (14) are not worn or damaged and that they properly guide the actuator (12).
13. Use a screwdriver to push down on the trip rod yoke (13), and snap the toggles down. See Fig. 4.
16. Remove the exhaust valve poppets (26) by cutting them with a side cutter, then pull them out of the actuator (12).
17. Clean all the parts carefully in a compatible solvent and inspect them for wear or damage. Use all the repair kit parts during reassembly, and replace other parts as necessary.

WARNING

MOVING PARTS HAZARD To reduce the risk of pinching or amputating your fingers, keep your fingers clear of the toggle assemblies when you are snapping the toggles (M in Fig. 4 ) up or down.

18. Check the surfaces of the piston, piston rod, and cylinder wall for scratches or wear. A scored rod will cause premature packing wear and leaking.
19. Lubricate all parts with a light, waterproof grease.

Page 12 of the Graco Series B user manual — CAUTION
Page 12 · click to enlarge
Page 12

Air Motor and Throat Service

Graco Series B — Air Motor and Throat Service diagram (page 12)
Fig. 5 · Air Motor and Throat Service

Cut off tops of poppets as indicated by dotted lines.

Turn lock- wire s up.

Reassembly

1. Place the piston rod (29) flats in the vice with the air motor up.
7. Measuring with the gauge (Part No.171818), create 0.125 in. (3.18 mm) of clearance between the inlet valve poppets (32*) and the piston seat when the inlet valve is open. See the Cutaway View Fig. 4.
2. Pull the exhaust valve poppets (26*) into the valve actuator (12), and clip off the top parts of the poppets (shown with dotted lines in the Cutaway View in Fig. 4).

poppets and the piston seat by turning the top valve nuts (21*).

3. Install the grommets (17*) in the actuator (12), place the inlet valve poppets (32*) in the piston, and thread the bottom valve nuts (21*) onto the inlet valve poppets until there are a few threads left before the threads run out.
8. Tighten the bottom valve nuts (21*) securely by hand.
9. Align the holes in the valve nuts (21*) and the slots on the tops of the inlet valve poppets (32*), and drop the lock wires (22*) through the holes in the valve nuts and into the slots in the inlet valve poppets. Pull the lock wires down tightly, and bend the ends with pliers so that they cannot be pulled back out of the holes.

onto the poppets, they will run off of the threaded part of the poppets.

4. Grease heavily and place the trip rod (31) in the piston, place the actuator (12) in the yoke (13), and place the well-greased actuator/yoke assembly in the piston, with the trip rod going through the center holes of the actuator and yoke and the inlet valve poppets (32*) going through the grommets (17*).

CAUTION

Never re-use the old lock wires. They get brittle and will break easily from too much bending.

5. Thread the top valve nuts (21*) onto the inlet valve poppets (32*) until one thread of the inlet valve poppets is exposed above the valve nuts.
10. Grease and install the new o-rings (19* and 20*) on the piston assembly (27) and in the groove in the air motor base (28).
6. Install the toggle pins (15) in the yoke (13), place the toggle arm (23) ends of the toggle assembly (M) onto the toggle pins, and snap the pivot pin (16) ends of the toggle assembly into the lugs (L).
11. Grease and reinstall the vee block seal (10 ) in the groove in the air motor base (28).
Show 4 more labels / short text on this page
26* 14 · 21* · Cutaway View ·
Page 13 of the Graco Series B user manual — Reassembly
Page 13 · click to enlarge
Page 13

Air Motor and Throat Service

12. Slide the piston rod (29) down through the packing, and lower the piston (27) into the air motor base (28).
17. Clamp the flats of the piston/valve seat (109) in a vice, and, using a crow’s-foot wrench, torque the piston rod (29) to the piston valve seat to 40 to 60 ft-lb.
13. Clamp the air motor base (28) in a vise horizontally by closing the vice jaws on the flange.
18. Clamp the air motor base (28) in a vise horizontally by closing the vice jaws on the flange
14. Install the u-cup packing (107 ) with the lips up, and place the piston washer (113) on the piston/ valve seat (109).
19. Use a strap wrench to screw the displacement pump cylinder (110) to the air motor base (28), and torque with a crow’s-foot wrench to 95 to 105 ft-lb.

(107) face up. See Fig. 3.

20. Before remounting the pump, connect an air hose and run the air motor slowly, at about 40 psi (0.28 MPa, 2.8 bar) to see that it operates smoothly.
15. Place the piston ball (103) in the piston rod (29).
16. Apply Loctite to the threads of the piston/valve seat (109), and thread the assembly from Step 14 onto the piston rod (29).
21. Reconnect the ground wire before regular operation of the pump. Displacement Pump Service

Disassembly

1. Follow the Pressure Relief Procedure on page 8 .
2. Follow steps 1 through 6 of Disassembly on page 10.

includes repair parts for the pump throat and piston. Use all the parts in the kit for the best results. Parts included in the kit are marked with a dagger, for example (7), in the text and drawings. See the Parts List on page 16.

3. Carefully inspect the smooth, inner surface of the cylinder (110) for scoring or irregular surfaces. Such damage causes premature seal wear and leaking. Replace the cylinder as needed.
1. Flush the pump. Follow the Pressure Relief Procedure on page 8, before proceeding.

Reassembly

2. Disconnect the hoses, remove the pump from its mounting, and clamp the air motor base (28) in a vise horizontally by closing the vice jaws on the flange.

Do steps 14 through 21 in Air Motor and Throat Service on this page.

Intake Valve See Fig 5.

1. Follow the Pressure Relief Procedure on page 8 .
2. Unscrew the valve housing (111). Remove the o-ring (105 ), retainer (112), and ball (104).

110 107 112

3. Inspect the parts for wear or damage. If the ball is nicked, replace it. Reassemble, using grease on the male threads.

Displacement Pump See Fig 5.

as you disassemble them. Replace parts as needed. For best results, always replace all the o-rings and packings when you disassem- ble the pump.

Included in Repair Kit 237602.

Show 6 more labels / short text on this page
108 · · 105 · Lips face up · ·
Page 14 of the Graco Series B user manual — Air Motor Parts Drawing
Page 14 · click to enlarge
Page 14

Air Motor Parts Drawing

Graco Series B — Air Motor Parts Drawing diagram (page 14)
Fig. 6 · Air Motor Parts Drawing
Show 6 more labels / short text on this page
107 · 108 · · 105 · *19 ·
Page 15 of the Graco Series B user manual — Air Motor Parts List
Page 15 · click to enlarge
Page 15

Air Motor Parts List

Ref. No. Part No. Description Qty.

Ref. No. Part No. Description Qty.

3 101578 SCREW, cap, hex hd 8 5 102656 MUFFLER, air exhaust 1 7 116343 SCREW, grounding 1 10 112130 SEAL, pump 1 11 156698 PACKING, o-ring 1 12 158359 ACTUATOR, valve, air 2 13 158360 YOKE, rod, trip 1 15 158362 PIN, toggle 2 16 158364 PIN, pivot 2 17* 158367 GROMMET, inlet valve 2 18 158377 PACKING, ring, seal 1 19* 158378 PACKING, o-ring 1 20* 158379 PACKING, o-ring 1 21* 160261 NUT, valve 4 22* 160618 WIRE, lock 2 23 160623 ARM, toggle 2 24 190929 LIFT RING 1

25 167585 SPRING, helical compression 2 26* 170709 POPPET, exhaust valve 2 27 207391 PISTON, includes items 27a to 27c (also includes 207385 repair kit when ordered as a replacement part) 1 27a 102975 SCREW, rd hd mach; 6–32 x 1/4” 2 27b 158361 CLIP, Spring 2 27c BARE PISTON (not sold separately) 1 28 190229 BASE, motor, air 1 29 190233 ROD, piston 1 30 15E954 CYLINDER, motor, air 1 31 207150 ROD, trip 1 32* 236079 POPPET, inlet valve 2 33 119344 LABEL, designation 1 35 290259 LABEL, warning 1

* Included in Air Motor Repair Kit 207385, which may be purchased separately.

Included in Pump Repair Kit 237602, which may be purchased separately.

Extra warning labels are available at no cost.

Page 16 of the Graco Series B user manual — Model 237526, Series B
Page 16 · click to enlarge
Page 16

Displacement Pump Parts Drawing and List

Model 237526, Series B

Ref No. Part No. Description Qty.

Ref No. Part No. Description Qty.

10 112130 SEAL, block, vee shown on page 14 1 101 AIR MOTOR See parts on page 14 1 103 101178 BALL, piston; metallic 1 104 108001 BALL; sst 1 105 110828 PACKING, o-ring 1 107 112565 PACKING, u-cup 1 108 166071 PACKING, o-ring 1

109 189707 PISTON/SEAT, valve 1 110 189708 CYLINDER, pump 1 111 189709 VALVE HOUSING, 1 1/2” npt(f) 1 112 189710 RETAINER, ball 1 113 189711 WASHER, piston 1

These parts are included in Pump Repair Kit 237602, which may be purchased separately.

Lips face up

Show 6 more labels / short text on this page
107 · · 108 · 105 · ·
Page 17 of the Graco Series B user manual — Dimensions
Page 17 · click to enlarge
Page 17

Dimensions

MODEL 237526 Series B

3/4-in. npt(f) fluid outlet

1/2-in. npt(f) air inlet

3/4-in. npt(f) muffler port

29.4 in. (747 mm)

11.0 in. (279 mm)

1 1/2-in. npt(f) fluid intake

grounding screw · ·

Page 18 of the Graco Series B user manual — Technical Data
Page 18 · click to enlarge
Page 18

Mounting Hole Layout

4.12 in. (104.6 mm) diam- eter clearance hole 45

Four 0.406-in. (10.3 mm) holes on 7-in. (177.8 mm) bolt circle

8.0 in. (203.2 mm) diameter of

Technical Data

Maximum working pressure 540 psi (3.7 MPa, 37 bar) Fluid pressure ratio 3:1 Air operating range 40 to 180 psi (0.28 to 1.2 MPa, 2.8 to 12 bar) Air consumption 3 ft3/min per gallon pumped,

(0.022 m3/min per liter pumped) up to 8 ft3/min (0.058 m3/min) with pump

operating within recommended range Pump cycles per gallon (per liter) 6 (1.6) Maximum recommended pump speed 66 cycles/min;

12 gpm (45 lpm) Recommended speed for optimum pump life 15 to 25 cycles per min Piston seals polyurethane Rod seals nitrile Wetted parts aluminum, steel, nitrile Approximate weight 46 lb (21 kg) * Sound pressure 82 dB(A)

* Sound pressure reading taken with pump operating at 60 cycles per minute at 100 psi (0.7 MPa, 7 bar). Sound pressure measured per CAGI-PNEUROP, 1971.

flange ·

Page 20 of the Graco Series B user manual — Graco Phone Numbers
Page 20 · click to enlarge
Page 20

Graco Standard Warranty

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub- stitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais- sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.

Graco Phone Numbers

TO PLACE AN ORDER, contact your Graco distributor, or call one of the following numbers

to identify the distributor closest to you:

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

This manual contains English. MM 308485

Graco HeadquartersMinneapolis International Offices: Belgium, Korea, China, Japan

www.graco.com 308485 01/1995, Revised 3/2007

1–800–533–9655 Toll Free · 612–623–6928 612–378–3590 Fax ·

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Pump fails to operateInadequate air supply pressure or restricted air linesIncrease air supply; clear p.9
Pump fails to operateClosed or clogged dispensing valveOpen; clean p.9
Pump fails to operateClogged fluid lines, hoses, valves, etc.Clear* p.9
Pump fails to operateDamaged air motorService air motor p.9
Pump fails to operateExhausted fluid supplyRefill and reprime or flush p.9
Continuous air exhaustWorn or damaged air motor gas- ket, packing, seal, etc.Service air motor p.9
Erratic pump operationExhausted fluid supplyRefill and reprime or flush p.9
Erratic pump operationHeld open or worn intake valve or piston packingsClear; service p.9
Pump operates, but output low on up strokeHeld open piston valve or worn piston packingsClear; service p.9
Pump operates, but output low on down strokeHeld open or worn intake valveClear; service p.9
Pump operates, but output low on both strokesInadequate air supply pressure or restricted air linesIncrease air supply; clear p.9
Pump operates, but output low on both strokesClosed or clogged valvesOpen; clean p.9

Ask about the Graco Series B

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco Series B

Be the first to ask — other owners or our team will answer.

Original document

Graco Series B manual PDF

20 pages·338 KB·Marine Sanitation System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…