EN
Graco logo
Official user manual

Graco 206405

24 pages·328 KB·Marine Sanitation System·PDF·ENDEFRITNLJA
Graco 206405
Table of Contents 1 sections Parts ShowHide
Page 1 of the Graco 206405 user manual — 04208B
Page 1 · click to enlarge
Page 1

Instructions–Parts List

15:1 Fire-Ball 300 Pumps

For pumping petroleum–based undercoating material.

2700 psi (18.6 MPa, 186 bar) Maximum Working Pressure 180 psi (1.2 Ma, 12 bar) Maximum Air Input Pressure

Model No. 206405, Series K 35 lb. pail size Model No. 206699, Series J 120 lb. drum size Model No. 206700, Series J 400 lb. drum size

This product is designed to be used for pumping non-corrosive and non-abrasive fluids only. Any other use can cause unsafe operating conditions and result in component rupture, fire, or explosion, which can cause serious injury, including skin injection.

Table of Contents

Warnings 2 Installation 6 Operation 8 Maintenance 10 Troubleshooting Guide 12 Air Motor Service 13 Displacement Pump Service 16 Parts 18 Mounting Hole Layout 23 Dimensional Drawings 23 Technical Data 23 Graco Warranty 24 Graco Phone Numbers 24

04208B

Model 206405 Shown

Page 2 of the Graco 206405 user manual — INSTRUCTIONS
Page 2 · click to enlarge
Page 2

Symbols

Caution Symbol

Warning Symbol

CAUTION

This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.

This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.

EQUIPMENT MISUSE HAZARD

Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.

INSTRUCTIONS

This equipment is for professional use only.

Read all instruction manuals, tags, and labels before operating the equipment.

Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor.

Do not alter or modify this equipment. Use only genuine Graco parts and accessories.

Check equipment daily. Repair or replace worn or damaged parts immediately.

Do not exceed the maximum working pressure stated on the equipment or in the Technical Data for your equipment. Do not exceed the maximum working pressure of the lowest rated component in your system.

Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Tech- nical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.

Handle hoses carefully. Do not use hoses to pull equipment.

Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 66C (150F) or below –40C (–40F).

Wear hearing protection when operating this equipment.

Do not lift pressurized equipment.

Comply with all applicable local, state, and national fire, electrical, and safety regulations.

Page 3 of the Graco 206405 user manual — MOVING PARTS HAZARD
Page 3 · click to enlarge
Page 3

SKIN INJECTION HAZARD

Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury.

Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate surgical treatment..

Do not point the gun at anyone or at any part of the body.

Do not put your hand or fingers over the spray tip.

Do not stop or deflect leaks with your hand, body, glove or rag.

Do not “blow back” fluid; this is not an air spray system.

Always have the tip guard and the trigger guard on the gun when spraying.

Check the gun diffuser operation weekly. Refer to the gun manual.

Be sure the gun trigger safety operates before spraying.

Close the gun ball valves when you stop spraying.

Lock the gun trigger safety when you stop spraying.

Follow the Pressure Relief Procedure on page 8 if the spray tip clogs and before cleaning, checking or servicing the equipment.

Tighten all fluid connections before operating the equipment.

Check the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. Do not repair high pressure couplings; you must replace the entire hose.

Fluid hoses must have spring guards on both ends, to help protect them from rupture caused by kinks or bends near the couplings.

MOVING PARTS HAZARD

Moving parts can pinch or amputate your fingers.

Keep clear of all moving parts when starting or operating the pump.

Before checking or servicing the equipment, follow the Pressure Relief Procedure on page 8 to prevent the equipment from starting unexpectedly.

Page 4 of the Graco 206405 user manual — TOXIC FLUID HAZARD
Page 4 · click to enlarge
Page 4

FIRE AND EXPLOSION HAZARD

Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.

Ground the equipment and the object being sprayed. Refer to Grounding on page 7.

If there is any static sparking or you feel an electric shock while using this equipment, stop spray- ing immediately. Do not use the equipment until you identify and correct the problem.

Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being sprayed.

Keep the spray area free of debris, including solvent, rags, and gasoline.

Before operating this equipment, electrically disconnect all equipment in the spray area.

Before operating this equipment, extinguish all open flames or pilot lights in the spray area.

Do not smoke in the spray area.

Do not turn on or off any light switch in the spray area while operating or if fumes are present.

Do not operate a gasoline engine in the spray area.

TOXIC FLUID HAZARD

Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.

Know the specific hazards of the fluid you are using.

Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines.

Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer.

Page 5 of the Graco 206405 user manual — Notes
Page 5 · click to enlarge
Page 5

Notes

Page 6 of the Graco 206405 user manual — System Accessories
Page 6 · click to enlarge
Page 6

Installation

E F G

J H

K

A

B

M

D

KEY

A Electrically Conductive Air Hose B Female Quick Disconnect Coupler C Male Quick Disconnect Fitting D Air Line Filter E Air Regulator and Gauge F Bleed-Type Master Air Valve G Air Line Lubricator H Pump Runaway Valve J Pump Air Inlet K Ground Wire L Pressure Drain Valve M Electrically Conductive Fluid Hose N Spray Gun

N

1/2 in. (13 mm)

System Accessories

Figure 1 is only a guide to selecting and installing optional and required accessories. For help in design- ing a system to suit your needs, contact your Graco distributor.

To reduce the risk of serious injury including skin injection, splashing in the eyes or on the skin, and injury from moving parts, if you are adjusting or repairing the pump, two accessories are required in your system: a bleed-type master air valve (F) and a pressure drain valve (L).

Mount the pump to suit the type of installation planned. See page 23 for dimensions and mounting hole layout.

The bleed-type master air valve (F) relieves air trapped between it and the air motor after the air supply is shut off. Trapped air can cause the air motor to cycle unexpectedly if you are adjusting or repairing the pump. Install the valve near the pump air inlet, within easy reach of the pump.

The pressure drain valve (L) assists in relieving fluid pressure in the displacement pump, hoses and gun. Triggering the spray gun to relieve pres- sure may not be sufficient.

Page 7 of the Graco 206405 user manual — TI1052
Page 7 · click to enlarge
Page 7

Installation

Pump: use a ground wire and clamp as shown below.

CAUTION

Provide a bracket for mounting the air accessories. The fittings are not strong enough to support the accessories and may cause one or more to break.

Truck bed or platform: according to your local code.

Fluid hoses: use only electrically conductive hoses.

Air compressor: follow manufacturer’s recommen- dations.

A pump runaway valve (H) shuts off the air to the pump if the pump accelerates beyond the pre-ad- justed setting. A pump which runs too fast can be seriously damaged.

Spray gun: grounding is obtained through connec- tion to a properly grounded fluid hose and pump.

Object being sprayed: according to local code.

Fluid supply container: according to local code.

An air line lubricator (G) provides automatic air motor lubrication.

All solvent pails used when flushing or relieving pressure, always hold a metal part of the gun firmly to the side of a grounded metal pail, then trigger the gun.

A bleed-type master air valve (F) relieves air trapped between it and the motor when the valve is closed. Order Part No. 107142.

To ground the pump:

The air regulator (E) controls pump speed and pressure.

To ground the pump, use a ground wire and clamp as shown below. Remove the ground screw (Z) and insert through the eye of ring terminal at end of ground wire (Y). Fasten the ground screw back onto the pump and tighten securely. Connect the other end of the ground wire to a true earth ground. See Fig. 2. To order a ground wire and clamp, order Part No. 222011.

An air line filter (D) removes harmful dirt and contaminants from your compressed air supply.

A drain valve (L) is required near the pump fluid outlet to relieve fluid pressure in the pump, hose and gun. Order Part No. 210657.

Install an electrically conductive fluid hose (M) and spray gun (N).

Grounding

Y Z

Proper grounding is an essential part of maintaining a safe system.

To reduce the risk of static sparking, ground the pump. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Be sure to ground all of this equipment:

TI1052

Page 8 of the Graco 206405 user manual — CAUTION
Page 8 · click to enlarge
Page 8

Operation

Pressure Relief Procedure

Never operate the pump with the warning plate (20) or the identification plate (40) removed. These plates protect your fingers from pinching or am- putation by moving parts in the air motor.

SKIN INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you:

Starting and Adjusting the Pump

1. With the air regulator (E) closed, open the bleedtype master air valve (F).

are instructed to relieve the pressure, stop spraying, check or service any of the system equipment, or install or clean the spray tips.

2. Connect the air hose.
3. Trigger the spray gun (N) into a grounded metal pail, making firm metal-to-metal contact.
1. Lock the spray gun trigger safety.
2. Close the pump air regulator. Close the bleed-type master air valve (required in your system).
4. Open the pump air regulator (E) slowly, just until the pump is running. When the pump is primed and all air has been pushed out of the lines, release the spray gun trigger. With sufficient air supplied, the pump starts when the spray gun is triggered and shuts off when the trigger is released.
3. Unlock the gun trigger safety.
4. Hold a metal part of the spray gun firmly to a grounded metal waste container and trigger the gun to relieve the fluid pressure.
5. Lock the gun trigger safety.
6. Open the pump drain valve (required with your system) and leave it open until you are ready to spray again.
5. Adjust the air regulator just until you get adequate flow from the spray gun. Always run the pump at the lowest speed necessary.

If you suspect that the spray tip or hose is clogged or that fluid pressure is not fully relieved after following the steps above, very slowly loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually. Clear the tip or hose obstruction.

CAUTION

Never allow the pump to run dry of the fluid being pumped. A dry pump will quickly accelerate to a high speed, possibly damaging itself. If your pump acceler- ates quickly, or is running too fast, stop it immediately and check the fluid supply. If the supply container is empty and air has been pumped into the lines, prime the pump and lines with fluid, or flush it and leave it filled with a compatible solvent. Be sure to eliminate all air from the fluid lines. Use a pump runaway valve (K) to automatically shut off the pump if it starts to run too fast.

COMPONENT RUPTURE HAZARD Overpressurizing any component can result in rupture, fire, explosion, property damage, and serious injury. To reduce the risk of overpressurizing, know the Maximum Working Pressure of the lowest rated component in your system, and limit the air to the pump so that you never exceed that pressure.

6. Read and follow the instructions supplied with each component in your system.

To determine the fluid output pressure using the air regulator reading, multiply the pump ratio by the air pressure you set on the regulator gauge. Example:

7. If the pump will be unattended for any period of time, or to shut off the system at the end of the work shift, always follow the Pressure Relief Procedure , at the left.

15 (:1) ratio x 100 psi air = 1500 psi fluid output

[15 (:1) ratio x 7 bar air = 105 bar fluid output]

Page 9 of the Graco 206405 user manual — Notes
Page 9 · click to enlarge
Page 9

Notes

Page 10 of the Graco 206405 user manual — Lubrication
Page 10 · click to enlarge
Page 10

Maintenance

Shutdown and General Care

Flushing

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

1. To reduce the risk of skin injection, static sparking or splashing, Relieve the Pressure before flushing.

Always relieve the pressure when you shut down the pump.

If you are pumping fluid that dries or sets up, flush with a compatible solvent as often as necessary to prevent buildup in the pump and hoses.

2. Remove the spray tip.
3. Hold a metal part of the gun firmly to the side of a grounded metal pail. Use the lowest possible fluid pressure when flushing.

After every 40 hours of operation, adjust the pack- ing nut (42) as described on page 11.

Lubrication

The accessory air line lubricator (G) provides automat- ic air motor lubrication. For daily, manual lubrication follow this procedure:

1. Disconnect the regulator.
2. Place about 15 drops of light machine oil in the pump air inlet.
3. Reconnect the regulator.
4. Turn on the air supply to blow oil into the motor.
Page 11 of the Graco 206405 user manual — PINCH POINT
Page 11 · click to enlarge
Page 11

Maintenance

Packing Nut Adjustment

Graco 206405 — Packing Nut Adjustment diagram (page 11)
Fig. 1 · Packing Nut Adjustment
Graco 206405 — Packing Nut Adjustment diagram (page 11)
Fig. 2 · Packing Nut Adjustment

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

PISTON

Graco 206405 — PISTON diagram (page 11)
Fig. 3

Keep your hand and fingers away from the piston when it is moving. As the piston moves into the pump base it can amputate fingers or break tools caught between the moving parts. Note the pinch point shown in Fig. 3. Be sure all air and fluid pressure is fully relieved before adjusting the piston or packing nut to reduce the risk of amputation.

PINCH POINT

BASE

FLUID OUTLET

NOTE: Perform this adjustment if: (a) material drips steadily from the air motor weep hole, which indicates the packings are too loose, (b) the pump requires more than 50 psi (.345 MPa, 3.4 bar) air pressure to cycle when the gun is triggered, which indicates the pack- ings are too tight, or (c) the pump has been in opera- tion for 40 hours.

WEEP HOLE LOCATED OPPOSITE FLUID OUTLET AND IN BOTTOM OF BASE Fig. 3

Graco 206405 — PINCH POINT diagram (page 11)
Fig. 4
1. Relieve the pressure . Follow the Pressure Relief Procedure on page 8.
2. Using a 1/4” nut driver, remove the six screws (24) from one of the muffler plates (20 or 40) and remove the muffler plate. See Fig. 4.
3. Check to see that the air motor piston is at the top of the stroke. If it is not, first read the warning above. Then, while keeping your fingers away from moving parts, apply very low pressure air to the air inlet to move the piston up. Close the air regulator and disconnect the air supply hose. Refer to Fig. 3.
Graco 206405 — PINCH POINT diagram (page 11)
Fig. 5
4. Use a 1/4” diameter rod, spanner wrench, or torque wrench to tighten the packing nut. First loosen the nut, then tighten snugly, and finally tighten an additional 1/2 turn (20–25 ft–lbs). See Fig. 5.
5. Replace the muffler cover, and the six screws. See Fig. 4.
6. Reconnect the air line. After the pump is started, it should run at 40 psi (.276 MPa, 2.8 bar) with no load. Startup may require additional air pressure.
Page 12 of the Graco 206405 user manual — Troubleshooting
Page 12 · click to enlarge
Page 12

Troubleshooting

Graco 206405 — Troubleshooting diagram (page 12)
Fig. 6 · Troubleshooting
Graco 206405 — Troubleshooting diagram (page 12)
Fig. 7 · Troubleshooting

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

Never operate the pump with the warning plate (20) or the identification plate (40) removed. These plates protect your fingers from pinching or ampu- tation by moving parts in the air motor.

Relieve the Pressure before you check or service any system equipment.

ProblemCauseSolution Pump fails to operateLow air supply pressure or restricted air linesIncrease air supply; clear* Closed valvesOpen Clogged fluid lines, hoses, valves, etc.Clear* Damaged air motorService air motor Empty fluid supply containerRefill and reprime, or flush Continuous air exhaustWorn or damaged air motor gasket, packing, seal, etc.Service air motor Erratic pump operationEmpty fluid supply containerRefill and reprime, or flush Held open or worn intake valve or piston packingsClear; service Pump operates, but output is low on the up strokeHeld open or worn piston or packingsClear; service Pump operates, but output is low on the down strokeHeld open or worn intake valveClear; service Pump operates, but output is low on both strokesLow air supply pressure or restricted air linesIncrease air supply; clear* Closed valvesOpen Empty fluid supply containerRefill and reprime, or flush Clogged fluid lines, hoses, valves, etc.Clear* Packing nut too tightLoosen Loose packing nut or worn packingsTighten; replace
Graco 206405 — Troubleshooting diagram (page 12)
Fig. 8 · Troubleshooting

*Follow the Pressure Relief Procedure on page 8. Disconnect the fluid hose. If the pump starts when the air is turned on again, the hose or gun is clogged.

Page 13 of the Graco 206405 user manual — Air Motor & Throat Disassembly
Page 13 · click to enlarge
Page 13

Air Motor Service

Before you start:

Graco 206405 — Before you start: diagram (page 13)
Fig. 9 · Before you start:

Have all necessary parts on hand. Always replace the glands and bearing when replacing the pack- ings. Use all the parts in the repair kits for the best results. See page 18 to order the kits.

To avoid damaging the cylinder wall, lift the cylinder (51) straight up off the piston (59). Never tilt the cylinder as it is being removed.

Air Motor Repair Kit 206728. Parts included in this kit are marked with a dagger, (for example, 36†), in the text and drawings.

8. Remove the six screws (25). See Fig. 6. Pull the cylinder (51) straight up off the piston (59).

Displacement Pump Repair Kit 206925. Parts included in this kit are marked with one asterisk, (i.e., 6*), in the text and drawings.

9. Use a screwdriver to push down on the trip rod yoke (28), and snap the toggles down. See Fig. 7.

Two accessory tools should be ordered. Use Padded Pliers, 207579, to grip the trip rod without damaging its surface. Use Gauge, 171818, to ensure the proper clearance between the poppets and seat of the transfer valve.

Graco 206405 — Before you start: diagram (page 13)
Fig. 10 · Before you start:

Air Motor & Throat Disassembly

Graco 206405 — Air Motor & Throat Disassembly diagram (page 13)
Fig. 11 · Air Motor & Throat Disassembly

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

1. Flush the pump.
2. Relieve the pressure before proceeding.
3. Disconnect the hoses, remove the pump from its mounting, and clamp the air motor base (55) in a vise.
4. Use a strap wrench on the riser tube (12) to screw it out of the air motor base (55).
5. Pull the connecting rod (10) down as far as it will go.
6. Use a hammer and punch to remove the roll pin (4). Unscrew the connecting rod (10). See Fig. 6.
Graco 206405 — Air Motor & Throat Disassembly diagram (page 13)
Fig. 12 · Air Motor & Throat Disassembly

Do not damage the plated surface of the trip rod (54). Damaging the surface of the trip rod can result in erratic air motor operation. Use the special Padded Pliers, Part Number 207579, to grasp the rod.

7. Manually push up on the piston rod (41) to move the piston assembly (59) up as far as it will go. Unscrew the cap nut (47). Pull the nut up. Grip the trip rod (54) with padded pliers, and screw the nut off the rod. See Fig. 6.
Page 14 of the Graco 206405 user manual — Reassembly
Page 14 · click to enlarge
Page 14

Air Motor Service

Graco 206405 — Air Motor Service diagram (page 14)
Fig. 13 · Air Motor Service
Graco 206405 — Air Motor Service diagram (page 14)
Fig. 14 · Air Motor Service

33† 45†

33† 45†

To remove toggles: push in, swing up, ease out.

Push toggles (M) in and then up (shown in down position). 2

1 Cut off tops of poppets as indicated by dotted lines.

Turn wires up.

10. Remove the lockwires (34 † ) from the adjusting nuts (33 † ) of the transfer valves. Screw the top nuts off. Screw the poppet valve stems (45 † ) out of the grommets (32 † ) and the bottom nuts (30). Take the valve poppets off the stems and squeeze them firmly to check for cracks. See Fig. 7.

Reassembly

1. Clean all the parts in a compatible solvent and inspect for wear or damage. Check the polished surfaces of the piston (59), piston rod (41), and cylinder wall (51) for scratches or wear. A scored rod will cause premature packing wear and leaking. Use all the repair kit parts and replace other parts as necessary.
Graco 206405 — Reassembly diagram (page 14)
Fig. 15 · Reassembly

To reduce the risk of pinching or amputating your fingers, always keep fingers clear of the toggle assemblies (M).

2. Lubricate all parts with a light, waterproof grease.
3. One at a time, install these parts in the base (55): the gland (49*), five v-packings (48*) with lips facing down , bearing (50*), backup washer (43), flat packing (44*), and loosely screw in the packing nut (42). Be sure the o-rings (38 & 39 † ) are in place. See Fig. 6.
11. Grip the pivot pins (30) with pliers. Compress the springs (31), and swing the toggle assembly (M) up and away from the piston lugs (L). Remove the parts. Check to see that the valve actuator (35) is supported by the spring clips (58) but slides easily into them. See Fig. 7.
4. Pull the exhaust valve poppets (53 † ) into the valve actuator (35) and clip off the top part shown with dotted lines. See Fig. 8.
12. Remove the trip rod yoke (28), actuator (35) and trip rod (54). See Fig. 7. Check the exhaust valve poppets (53 † ) for cracks. To remove the exhaust valve poppets (53 † ), stretch them out and cut them with a sharp knife.
5. Install the grommets (32 † ) in the valve actuator (35). Install the trip rod (54) in the piston (59). Place the trip rod yoke (28) and valve actuator (35) on the trip rod. Be sure the o-ring (36*) is in place and that the valve actuator is supported by the spring clips (58), and reassemble the valve mechanism. See Fig. 7.
13. Remove one muffler plate (20 or 40). Pull the piston (59) up out of the base. Remove the throat packing nut (42) and packings. See Fig. 6.

32† · 53† 58 · Cutaway View

Page 15 of the Graco 206405 user manual — Air Motor Service
Page 15 · click to enlarge
Page 15

Air Motor Service

6. Install the bottom adjusting nuts (33) on the poppet valve stems (45 † ) and screw the stems into the grommets (32 † ). Screw the top nuts (33 † ) on the stems. Before installing the lockwires (34 † ) in the adjusting nuts, use the gauge 171818 to adjust the transfer valve so there is 0.145 in. (3.7 mm) clearance between the poppets and the seat when it is open. See Fig. 8.
9. Manually push on the piston rod (41) to move the piston (59) up as far as it will go. Grip the trip rod (54) with padded pliers and screw the cylinder cap nut (47) onto the trip rod. Pull the piston rod (41) to move the piston down. Be sure the o-ring (27) is in place at the top of the cylinder (51), and screw the cap nut into the cylinder.
10. Screw the connecting rod (10) into the piston rod (41) and secure with the pin (4*). Manually push on the piston rod (41) to move the piston (59) up as far as it will go. Screw the riser tube (12) into the base (55).

To reduce the risk of pinching or amputating your fingers, always keep fingers clear of the toggle assemblies (M).

11. Use a 1/4” diameter rod, spanner wrench, or torque wrench to tighten the packing nut (42). Tighten snugly and then tighten an additional 1/2 turn (20–25 ft–lbs).
7. Install the springs (31) and pivot pins (30) on the toggle arms (37). Snap the toggles to the up position. Refer to Fig. 7.
12. Install the muffler plate (20 or 40) using the six screws (24).
13. Connect an air hose and run the pump slowly [about 30 psi (2.1 bar)] to see that it operates smoothly.
8. Carefully lower the cylinder (51) over the piston (59) and onto the base (55). Secure with the six screws (25).
14. Remount the pump and reconnect the ground wire.
Page 16 of the Graco 206405 user manual — Displacement Pump Disassembly
Page 16 · click to enlarge
Page 16

Displacement Pump Service

Before you start:

1. Have all necessary parts on hand. Whenever you replace the packings, also replace the glands and bearing. If you are using a repair kit, use all the parts for the best results. See the parts pages to order the kits.
2. Displacement Pump Repair Kit 206925 includes repair parts for the pump throat and piston. Parts included in the kit are marked with one asterisk, for example (6*), in the text and drawings.
3. To replace the throat packings, which are included in Repair Kit 206728, refer to the Air Motor and Throat Disassembly on page 13.

Displacement Pump Disassembly

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

1. Flush the pump.
2. Relieve the Pressure
3. Disconnect the hoses, remove the pump from its mounting, and clamp the air motor base in a vise.
4. Unscrew the intake valve body (22) from the riser tube (12). See Fig. 9. Disassemble the intake valve.
5. Clean and inspect the parts for wear or damage, and replace parts as needed. Unless further service is needed, reassemble and reinstall the intake valve, using liquid sealant on the male threads. See Fig. 9.
6. Use a strap wrench on the riser tube (12) to screw it out of the air motor base (55). Carefully inspect the smooth inner surface of the cylinder for scoring or irregular surfaces. Such damage causes premature packing wear and leaking, so replace the part if damaged.
7. Unscrew the piston body (13) from the piston coupling (14). Remove the ball (2*), seat (19*), gasket (6*), bearing (18*), packing (17*), and seal (16). Do not remove the press-fit brass bearing (15*). See Fig. 9.

04212B Fig. 9

Show 10 more labels / short text on this page
†7 · *4 · *4 14 · 2* *19 · *6 · *17 · 18* · *15 · 13 16* · 3*
Page 17 of the Graco 206405 user manual — Displacement Pump Service
Page 17 · click to enlarge
Page 17

Displacement Pump Service

10. Install the gasket (7*[). Screw the riser tube (12) into the air motor base (55).
11. Reinstall the ball (3*), gasket (7), ball stop (21) and other gasket (7) in the intake valve housing (22). Screw the housing onto the riser tube (12).
8. Clean and inspect the parts and replace any that are worn or damaged. Be sure to check the copper gasket (46) in the motor base (55). Lubricate the parts with a light waterproof grease.
12. Be sure the ground wire is connected before regular operation of the pump.
9. Install the seal (16*), packing (17*), bearing (18*), gasket (6*), seat (19*) and ball (2*) on the piston body (13). The check ball seat (19*) may be reversed to provide a new seat. Screw the piston body (13) into the piston coupling (14).
Page 18 of the Graco 206405 user manual — 04213B
Page 18 · click to enlarge
Page 18

Parts

Graco 206405 — Parts diagram (page 18)
Fig. 16 · Parts

04213B

Page 19 of the Graco 206405 user manual — Model 206405, Series K 35 lb. pail size
Page 19 · click to enlarge
Page 19

Parts

Model 206405, Series K 35 lb. pail size

Ref No. Part No. Description Qty.

Ref No. Part No. Description Qty.

2* 100114 BALL, steel, 0.44” (11.2 mm) dia. 1 3* 100400 BALL, steel, 0.75” (19 mm) dia. 1 4* 101579 PIN, roll, 0.12” (3.2 mm) dia., 0.75” (19 mm) long 3 6* 150451 GASKET, copper 1 7*† 150694 GASKET, copper (qty 1 in kits 206925 and 206728) 3 10 165970 ROD, connecting, 5 1/4” (133 mm) long 1 12 165971 TUBE, riser, 11–11/16” (297 mm) long 1 13 160939 BODY, piston 1 14 160940 COUPLING, piston 1 15* 160941 BEARING, press fit, brass 1 16* 160942 SEAL, piston; PTFE 1 17* 160943 PACKING, block, nitrile rubber 1 18* 160944 BEARING, piston, brass 1 19* 160945 SEAT, piston, reversible 1 20** 234578 PLATE, warning (with muffler) 1 21 183326 STOP, ball 1 22 191080 HOUSING, intake valve 1 24** 100078 . SCREW, hex washer hd, mach,

37 160623 . ARM, toggle 2 38 160624 . O-RING, nitrile rubber 1 39† 160625 . O-RING, nitrile rubber 1 40** 234577 . PLATE, identification,

with muffler 1 41 160639 . ROD, piston 1 42 160640 . NUT, packing 1 43 160641 . WASHER, backup 1 44* 160644 . PACKING, flat leather 1 45† 236079 . VALVE, poppet 2 46 160932 . GASKET, copper 1 47 164704 . NUT, cylinder cap 1 48* 162391 . V-PACKING, leather 5 49* 168851 . GLAND, male 1 50* 168852 . BEARING, throat 1 51 160613 . CYLINDER, air motor 1 53† 170709 . POPPET, valve, urethane 2 54 203965 . ROD, trip 1 55 204896 . BASE, air motor 1 57 102975 . SCREW, rd hd mach,

6–32 x 1/4” 2 58 172866 . CLIP, spring 2 59 15K534 . PISTON, air motor 1 60 116343 . SCREW, ground 1 63 162718 . ADAPTER, 3/8 npt (m) x

8–32 x 3/8” 12 25 101578 . CAPSCREW, hex hd Nylock,

5/16–18 x 7/8” 6 27 156698 . O-RING, nitrile rubber 1 28 158360 . YOKE, rod, trip 1 29 158362 . PIN, toggle 2 30 158364 . PIN, pivot 2 31 167585 . SPRING, helical compression 2 32† 158367 . GROMMET; rubber 2 33† 160261 . NUT, adjusting 4 34† 160618 . WIRE, lock 2 35 172867 . ACTUATOR, valve 1 36† 160621 . O-RING, nitrile rubber 1

* These parts are included in Pump Repair Kit 206925,

which may be purchased separately.

** These parts are included in Muffler Repair Kit 222559, which may be purchased separately.

† These parts are included in Air Motor Repair Kit 206728, which may be purchased separately.

1/4 npt(f) 1

Page 20 of the Graco 206405 user manual — Model 206699, Series J 120 lb. drum size
Page 20 · click to enlarge
Page 20

Parts

Graco 206405 — Parts diagram (page 20)
Fig. 17 · Parts

Model 206699, Series J 120 lb. drum size

Model 206700, Series J 400 lb. drum size

04214B

Page 21 of the Graco 206405 user manual — Parts
Page 21 · click to enlarge
Page 21

Parts

Model 206699, Series J 120 lb. drum size Model 206700, Series J 400 lb. drum size

Ref. No. Part No. Description Qty.

Ref. No. Part No. Description Qty.

2* 100114 BALL, steel, 0.44” (11.2 mm) dia. 1 3* 100400 BALL, steel, 0.75” (19 mm) dia. 1 4* 101579 PIN, roll, 0.12” (3.2 mm) dia., 0.75” (19 mm) long 3 6* 150451 GASKET, copper 1 7*† 150694 GASKET, copper (qty 1 in kits 206925 and 206728) 3 10 160688 ROD, connecting, 18–15/16” (481 mm) long 1 (For Model 206699) 161050 ROD, connecting, 25 7/8” (657 mm) long 1 (For Model 206700) 12 160938 TUBE, riser, 25–3/8” (645 mm) long 1 (For Model 206699) 161051 TUBE, riser, 32 5/16” (821 mm) long 1 (For Model 206700) 13 160939 BODY, piston 1 14 160940 COUPLING, piston 1 15* 160941 BEARING, press fit, brass 1 16* 160942 SEAL, piston; PTFE 1 17* 160943 PACKING, block, nitrile rubber 1 18* 160944 BEARING, piston, brass 1 19* 160945 SEAT, piston, reversible 1 20** 234578 PLATE, warning (with muffler) 1 21 183326 STOP, ball 1 22 191080 HOUSING, intake valve 1 24** 100078 . SCREW, hex washer hd, mach,

33† 160261 . NUT, adjusting 4 34† 160618 . WIRE, lock 2 35 172867 . ACTUATOR, valve 1 36† 160621 . O-RING, nitrile rubber 1 37 160623 . ARM, toggle 2 38 160624 . O-RING, nitrile rubber 1 39† 160625 . O-RING, nitrile rubber 1 40** 234577 . PLATE, identification,

with muffler 1 41 160639 . ROD, piston 1 42 160640 . NUT, packing 1 43 160641 . WASHER, backup 1 44* 160644 . PACKING, flat leather 1 45† 236079 . VALVE, poppet 2 46 160932 . GASKET, copper 1 47 161435 . NUT, cylinder cap 1 48* 162391 . V-PACKING, leather 5 49* 168851 . GLAND, male 1 50* 168852 . BEARING, throat 1 51 160613 . CYLINDER, air motor 1 53† 170709 . POPPET, valve, urethane 2 54 203965 . ROD, trip 1 55 204896 . BASE, air motor 1 57 102975 . SCREW, rd hd mach,

6–32 x 1/4” 2 58 172866 . CLIP, spring 2 59 15K534 . PISTON, air motor 1 60 116343 . SCREW, ground 1 63 162718 . ADAPTER, 3/8 npt (m) x

8–32 x 3/8” 12 25 101578 . CAPSCREW, hex hd Nylock,

* These parts are included in Pump Repair Kit 206925,

5/16–18 x 7/8” 6 27 156698 . O-RING, nitrile rubber 1 28 158360 . YOKE, rod, trip 1 29 158362 . PIN, toggle 2 30 158364 . PIN, pivot 2 31 167585 . SPRING, helical compression 2 32† 158367 . GROMMET; rubber 2

which may be purchased separately.

** These parts are included in Muffler Repair Kit 222559, which may be purchased separately.

† These parts are included in Air Motor Repair Kit 206728, which may be purchased separately.

1/4 npt(f) 1

Page 22 of the Graco 206405 user manual — Notes
Page 22 · click to enlarge
Page 22

Notes

Page 23 of the Graco 206405 user manual — 04217B
Page 23 · click to enlarge
Page 23

Dimensions

Technical Data

Maximum Working Pressure 2700 psi (186 bar) Fluid pressure ratio 15:1 Air operating range 40 to 180 psi (3 to 12 bar) Air motor effective diameter 3 in. (76 mm) Stroke 3 in. (76 mm) Air consumption 17 cfm/gallon pumped at 100 psi

3/8 npt(f) Air Inlet

1/4 npt(f) Fluid Outlet

(0.476 m3/liter at 7 bar); up to 30 cfm with pump operated

at 180 psi and 66 cycles/min. (up to 0.84 m3/min with pump operated

at 12 bar and 66 cycles/min.) Pump cycles per gallon (liter) 90 (24) Delivery 0.66 gallons/minute (3 liters/minute) Maximum recommended pump speed 66 cycles/min;

Model 206405 13 inches (330 mm)

0.7 gpm (32 liter/min) Recommended speed for optimum pump life 15 to 25 cycles per min Wetted parts Carbon Steel, Brass, Copper, Aluminum, PTFE, Nitrile Rubber, Leather Approximate weight 22 lb (10 kg)

Model 206699 26.69 inches (677.7 mm)

Model 206700 33.62 inches (854 mm)

04217B

Mounting Hole Layout

2 Hole Mounting Pattern

4 Hole Mounting Pattern

Two or Four 0.265” (7 mm) Dia. Holes on 5” (127 mm) Bolt Circle

3” (76.2 mm) Dia.

161023 Gasket

Page 24 of the Graco 206405 user manual — Graco Phone Numbers
Page 24 · click to enlarge
Page 24

Graco Standard Warranty

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub- stitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais- sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.

Graco Phone Numbers

For the latest information about Graco products, visit www.graco.com

TO PLACE AN ORDER, contact your Graco distributor, or call one of the following numbers

to identify the distributor closest to you:

1–800–533–9655 Toll Free 612–623–6928 612–378–3590 Fax

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

This manual contains English. MM 306531

Graco HeadquartersMinneapolis International Offices: Belgium, China, Japan, Korea

GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 Copyright 1996, Graco Inc. is registered to ISO 9001

www.graco.com Revised 05/2009

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
Pump fails to operateLow air supply pressure or restricted air linesIncrease air supply; clear* p.12
Pump fails to operateClosed valvesOpen p.12
Pump fails to operateClogged fluid lines, hoses, valves, etc.Clear* p.12
Pump fails to operateDamaged air motorService air motor p.12
Pump fails to operateEmpty fluid supply containerRefill and reprime, or flush p.12
Continuous air exhaustWorn or damaged air motor gasket, packing, seal, etc.Service air motor p.12
Erratic pump operationEmpty fluid supply containerRefill and reprime, or flush p.12
Erratic pump operationHeld open or worn intake valve or piston packingsClear; service p.12
Pump operates, but output is low on the up strokeHeld open or worn piston or packingsClear; service p.12
Pump operates, but output is low on the down strokeHeld open or worn intake valveClear; service p.12
Pump operates, but output is low on both strokesLow air supply pressure or restricted air linesIncrease air supply; clear* p.12
Pump operates, but output is low on both strokesClosed valvesOpen p.12
Pump operates, but output is low on both strokesEmpty fluid supply containerRefill and reprime, or flush p.12
Pump operates, but output is low on both strokesClogged fluid lines, hoses, valves, etc.Clear* p.12
Pump operates, but output is low on both strokesPacking nut too tightLoosen p.12
Pump operates, but output is low on both strokesLoose packing nut or worn packingsTighten; replace p.12

Ask about the Graco 206405

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco 206405

Be the first to ask — other owners or our team will answer.

Original document

Graco 206405 manual PDF

24 pages·328 KB·Marine Sanitation System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…