15:1 Fire-Ball 300 Pumps
For pumping petroleum–based undercoating material.
2700 psi (18.6 MPa, 186 bar) Maximum Working Pressure 180 psi (1.2 Ma, 12 bar) Maximum Air Input Pressure
Model No. 206405, Series K 35 lb. pail size Model No. 206699, Series J 120 lb. drum size Model No. 206700, Series J 400 lb. drum size
This product is designed to be used for pumping non-corrosive and non-abrasive fluids only. Any other use can cause unsafe operating conditions and result in component rupture, fire, or explosion, which can cause serious injury, including skin injection.
Warnings 2 Installation 6 Operation 8 Maintenance 10 Troubleshooting Guide 12 Air Motor Service 13 Displacement Pump Service 16 Parts 18 Mounting Hole Layout 23 Dimensional Drawings 23 Technical Data 23 Graco Warranty 24 Graco Phone Numbers 24
Model 206405 Shown

Warning Symbol
CAUTION
This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.
This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions.
Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury.
This equipment is for professional use only.
Read all instruction manuals, tags, and labels before operating the equipment.
Use the equipment only for its intended purpose. If you are not sure, call your Graco distributor.
Do not alter or modify this equipment. Use only genuine Graco parts and accessories.
Check equipment daily. Repair or replace worn or damaged parts immediately.
Do not exceed the maximum working pressure stated on the equipment or in the Technical Data for your equipment. Do not exceed the maximum working pressure of the lowest rated component in your system.
Use fluids and solvents which are compatible with the equipment wetted parts. Refer to the Tech- nical Data section of all equipment manuals. Read the fluid and solvent manufacturer’s warnings.
Handle hoses carefully. Do not use hoses to pull equipment.
Route hoses away from traffic areas, sharp edges, moving parts, and hot surfaces. Do not expose Graco hoses to temperatures above 66C (150F) or below –40C (–40F).
Wear hearing protection when operating this equipment.
Do not lift pressurized equipment.
Comply with all applicable local, state, and national fire, electrical, and safety regulations.

Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely serious injury, including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury.
Fluid injected into the skin might look like just a cut, but it is a serious injury. Get immediate surgical treatment..
Do not point the gun at anyone or at any part of the body.
Do not put your hand or fingers over the spray tip.
Do not stop or deflect leaks with your hand, body, glove or rag.
Do not “blow back” fluid; this is not an air spray system.
Always have the tip guard and the trigger guard on the gun when spraying.
Check the gun diffuser operation weekly. Refer to the gun manual.
Be sure the gun trigger safety operates before spraying.
Close the gun ball valves when you stop spraying.
Lock the gun trigger safety when you stop spraying.
Follow the Pressure Relief Procedure on page 8 if the spray tip clogs and before cleaning, checking or servicing the equipment.
Tighten all fluid connections before operating the equipment.
Check the hoses, tubes, and couplings daily. Replace worn or damaged parts immediately. Do not repair high pressure couplings; you must replace the entire hose.
Fluid hoses must have spring guards on both ends, to help protect them from rupture caused by kinks or bends near the couplings.
Moving parts can pinch or amputate your fingers.
Keep clear of all moving parts when starting or operating the pump.
Before checking or servicing the equipment, follow the Pressure Relief Procedure on page 8 to prevent the equipment from starting unexpectedly.

Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury.
Ground the equipment and the object being sprayed. Refer to Grounding on page 7.
If there is any static sparking or you feel an electric shock while using this equipment, stop spray- ing immediately. Do not use the equipment until you identify and correct the problem.
Provide fresh air ventilation to avoid the buildup of flammable fumes from solvents or the fluid being sprayed.
Keep the spray area free of debris, including solvent, rags, and gasoline.
Before operating this equipment, electrically disconnect all equipment in the spray area.
Before operating this equipment, extinguish all open flames or pilot lights in the spray area.
Do not smoke in the spray area.
Do not turn on or off any light switch in the spray area while operating or if fumes are present.
Do not operate a gasoline engine in the spray area.
Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed.
Know the specific hazards of the fluid you are using.
Store hazardous fluid in an approved container. Dispose of hazardous fluid according to all local, state and national guidelines.
Always wear protective eyewear, gloves, clothing and respirator as recommended by the fluid and solvent manufacturer.


J H
K
A
B
M
D
KEY
A Electrically Conductive Air Hose B Female Quick Disconnect Coupler C Male Quick Disconnect Fitting D Air Line Filter E Air Regulator and Gauge F Bleed-Type Master Air Valve G Air Line Lubricator H Pump Runaway Valve J Pump Air Inlet K Ground Wire L Pressure Drain Valve M Electrically Conductive Fluid Hose N Spray Gun
1/2 in. (13 mm)
Figure 1 is only a guide to selecting and installing optional and required accessories. For help in design- ing a system to suit your needs, contact your Graco distributor.
To reduce the risk of serious injury including skin injection, splashing in the eyes or on the skin, and injury from moving parts, if you are adjusting or repairing the pump, two accessories are required in your system: a bleed-type master air valve (F) and a pressure drain valve (L).
Mount the pump to suit the type of installation planned. See page 23 for dimensions and mounting hole layout.
The bleed-type master air valve (F) relieves air trapped between it and the air motor after the air supply is shut off. Trapped air can cause the air motor to cycle unexpectedly if you are adjusting or repairing the pump. Install the valve near the pump air inlet, within easy reach of the pump.
The pressure drain valve (L) assists in relieving fluid pressure in the displacement pump, hoses and gun. Triggering the spray gun to relieve pres- sure may not be sufficient.

Pump: use a ground wire and clamp as shown below.
Provide a bracket for mounting the air accessories. The fittings are not strong enough to support the accessories and may cause one or more to break.
Truck bed or platform: according to your local code.
Fluid hoses: use only electrically conductive hoses.
Air compressor: follow manufacturer’s recommen- dations.
A pump runaway valve (H) shuts off the air to the pump if the pump accelerates beyond the pre-ad- justed setting. A pump which runs too fast can be seriously damaged.
Spray gun: grounding is obtained through connec- tion to a properly grounded fluid hose and pump.
Object being sprayed: according to local code.
Fluid supply container: according to local code.
An air line lubricator (G) provides automatic air motor lubrication.
All solvent pails used when flushing or relieving pressure, always hold a metal part of the gun firmly to the side of a grounded metal pail, then trigger the gun.
A bleed-type master air valve (F) relieves air trapped between it and the motor when the valve is closed. Order Part No. 107142.
The air regulator (E) controls pump speed and pressure.
To ground the pump, use a ground wire and clamp as shown below. Remove the ground screw (Z) and insert through the eye of ring terminal at end of ground wire (Y). Fasten the ground screw back onto the pump and tighten securely. Connect the other end of the ground wire to a true earth ground. See Fig. 2. To order a ground wire and clamp, order Part No. 222011.
An air line filter (D) removes harmful dirt and contaminants from your compressed air supply.
A drain valve (L) is required near the pump fluid outlet to relieve fluid pressure in the pump, hose and gun. Order Part No. 210657.
Install an electrically conductive fluid hose (M) and spray gun (N).
Y Z
Proper grounding is an essential part of maintaining a safe system.
To reduce the risk of static sparking, ground the pump. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Be sure to ground all of this equipment:

Never operate the pump with the warning plate (20) or the identification plate (40) removed. These plates protect your fingers from pinching or am- putation by moving parts in the air motor.
SKIN INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally. Fluid under high pressure can be injected through the skin and cause serious injury. To reduce the risk of an injury from injection, splashing fluid, or moving parts, follow the Pressure Relief Procedure whenever you:
are instructed to relieve the pressure, stop spraying, check or service any of the system equipment, or install or clean the spray tips.
If you suspect that the spray tip or hose is clogged or that fluid pressure is not fully relieved after following the steps above, very slowly loosen the tip guard retaining nut or hose end coupling and relieve pressure gradually. Clear the tip or hose obstruction.
Never allow the pump to run dry of the fluid being pumped. A dry pump will quickly accelerate to a high speed, possibly damaging itself. If your pump acceler- ates quickly, or is running too fast, stop it immediately and check the fluid supply. If the supply container is empty and air has been pumped into the lines, prime the pump and lines with fluid, or flush it and leave it filled with a compatible solvent. Be sure to eliminate all air from the fluid lines. Use a pump runaway valve (K) to automatically shut off the pump if it starts to run too fast.
COMPONENT RUPTURE HAZARD Overpressurizing any component can result in rupture, fire, explosion, property damage, and serious injury. To reduce the risk of overpressurizing, know the Maximum Working Pressure of the lowest rated component in your system, and limit the air to the pump so that you never exceed that pressure.
To determine the fluid output pressure using the air regulator reading, multiply the pump ratio by the air pressure you set on the regulator gauge. Example:
15 (:1) ratio x 100 psi air = 1500 psi fluid output
[15 (:1) ratio x 7 bar air = 105 bar fluid output]


Flushing
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.
Always relieve the pressure when you shut down the pump.
If you are pumping fluid that dries or sets up, flush with a compatible solvent as often as necessary to prevent buildup in the pump and hoses.
After every 40 hours of operation, adjust the pack- ing nut (42) as described on page 11.
The accessory air line lubricator (G) provides automat- ic air motor lubrication. For daily, manual lubrication follow this procedure:



To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

Keep your hand and fingers away from the piston when it is moving. As the piston moves into the pump base it can amputate fingers or break tools caught between the moving parts. Note the pinch point shown in Fig. 3. Be sure all air and fluid pressure is fully relieved before adjusting the piston or packing nut to reduce the risk of amputation.
BASE
FLUID OUTLET
NOTE: Perform this adjustment if: (a) material drips steadily from the air motor weep hole, which indicates the packings are too loose, (b) the pump requires more than 50 psi (.345 MPa, 3.4 bar) air pressure to cycle when the gun is triggered, which indicates the pack- ings are too tight, or (c) the pump has been in opera- tion for 40 hours.
WEEP HOLE LOCATED OPPOSITE FLUID OUTLET AND IN BOTTOM OF BASE Fig. 3





To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.
Never operate the pump with the warning plate (20) or the identification plate (40) removed. These plates protect your fingers from pinching or ampu- tation by moving parts in the air motor.
Relieve the Pressure before you check or service any system equipment.

*Follow the Pressure Relief Procedure on page 8. Disconnect the fluid hose. If the pump starts when the air is turned on again, the hose or gun is clogged.


Have all necessary parts on hand. Always replace the glands and bearing when replacing the pack- ings. Use all the parts in the repair kits for the best results. See page 18 to order the kits.
To avoid damaging the cylinder wall, lift the cylinder (51) straight up off the piston (59). Never tilt the cylinder as it is being removed.
Air Motor Repair Kit 206728. Parts included in this kit are marked with a dagger, (for example, 36†), in the text and drawings.
Displacement Pump Repair Kit 206925. Parts included in this kit are marked with one asterisk, (i.e., 6*), in the text and drawings.
Two accessory tools should be ordered. Use Padded Pliers, 207579, to grip the trip rod without damaging its surface. Use Gauge, 171818, to ensure the proper clearance between the poppets and seat of the transfer valve.


To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.

Do not damage the plated surface of the trip rod (54). Damaging the surface of the trip rod can result in erratic air motor operation. Use the special Padded Pliers, Part Number 207579, to grasp the rod.



33† 45†
33† 45†
To remove toggles: push in, swing up, ease out.
Push toggles (M) in and then up (shown in down position). 2
1 Cut off tops of poppets as indicated by dotted lines.
Turn wires up.

To reduce the risk of pinching or amputating your fingers, always keep fingers clear of the toggle assemblies (M).
32† · 53† 58 · Cutaway View

To reduce the risk of pinching or amputating your fingers, always keep fingers clear of the toggle assemblies (M).

To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8.
04212B Fig. 9




Ref No. Part No. Description Qty.
Ref No. Part No. Description Qty.
2* 100114 BALL, steel, 0.44” (11.2 mm) dia. 1 3* 100400 BALL, steel, 0.75” (19 mm) dia. 1 4* 101579 PIN, roll, 0.12” (3.2 mm) dia., 0.75” (19 mm) long 3 6* 150451 GASKET, copper 1 7*† 150694 GASKET, copper (qty 1 in kits 206925 and 206728) 3 10 165970 ROD, connecting, 5 1/4” (133 mm) long 1 12 165971 TUBE, riser, 11–11/16” (297 mm) long 1 13 160939 BODY, piston 1 14 160940 COUPLING, piston 1 15* 160941 BEARING, press fit, brass 1 16* 160942 SEAL, piston; PTFE 1 17* 160943 PACKING, block, nitrile rubber 1 18* 160944 BEARING, piston, brass 1 19* 160945 SEAT, piston, reversible 1 20** 234578 PLATE, warning (with muffler) 1 21 183326 STOP, ball 1 22 191080 HOUSING, intake valve 1 24** 100078 . SCREW, hex washer hd, mach,
37 160623 . ARM, toggle 2 38 160624 . O-RING, nitrile rubber 1 39† 160625 . O-RING, nitrile rubber 1 40** 234577 . PLATE, identification,
with muffler 1 41 160639 . ROD, piston 1 42 160640 . NUT, packing 1 43 160641 . WASHER, backup 1 44* 160644 . PACKING, flat leather 1 45† 236079 . VALVE, poppet 2 46 160932 . GASKET, copper 1 47 164704 . NUT, cylinder cap 1 48* 162391 . V-PACKING, leather 5 49* 168851 . GLAND, male 1 50* 168852 . BEARING, throat 1 51 160613 . CYLINDER, air motor 1 53† 170709 . POPPET, valve, urethane 2 54 203965 . ROD, trip 1 55 204896 . BASE, air motor 1 57 102975 . SCREW, rd hd mach,
6–32 x 1/4” 2 58 172866 . CLIP, spring 2 59 15K534 . PISTON, air motor 1 60 116343 . SCREW, ground 1 63 162718 . ADAPTER, 3/8 npt (m) x
8–32 x 3/8” 12 25 101578 . CAPSCREW, hex hd Nylock,
5/16–18 x 7/8” 6 27 156698 . O-RING, nitrile rubber 1 28 158360 . YOKE, rod, trip 1 29 158362 . PIN, toggle 2 30 158364 . PIN, pivot 2 31 167585 . SPRING, helical compression 2 32† 158367 . GROMMET; rubber 2 33† 160261 . NUT, adjusting 4 34† 160618 . WIRE, lock 2 35 172867 . ACTUATOR, valve 1 36† 160621 . O-RING, nitrile rubber 1
* These parts are included in Pump Repair Kit 206925,
which may be purchased separately.
** These parts are included in Muffler Repair Kit 222559, which may be purchased separately.
† These parts are included in Air Motor Repair Kit 206728, which may be purchased separately.
1/4 npt(f) 1


Model 206700, Series J 400 lb. drum size
04214B

Model 206699, Series J 120 lb. drum size Model 206700, Series J 400 lb. drum size
Ref. No. Part No. Description Qty.
Ref. No. Part No. Description Qty.
2* 100114 BALL, steel, 0.44” (11.2 mm) dia. 1 3* 100400 BALL, steel, 0.75” (19 mm) dia. 1 4* 101579 PIN, roll, 0.12” (3.2 mm) dia., 0.75” (19 mm) long 3 6* 150451 GASKET, copper 1 7*† 150694 GASKET, copper (qty 1 in kits 206925 and 206728) 3 10 160688 ROD, connecting, 18–15/16” (481 mm) long 1 (For Model 206699) 161050 ROD, connecting, 25 7/8” (657 mm) long 1 (For Model 206700) 12 160938 TUBE, riser, 25–3/8” (645 mm) long 1 (For Model 206699) 161051 TUBE, riser, 32 5/16” (821 mm) long 1 (For Model 206700) 13 160939 BODY, piston 1 14 160940 COUPLING, piston 1 15* 160941 BEARING, press fit, brass 1 16* 160942 SEAL, piston; PTFE 1 17* 160943 PACKING, block, nitrile rubber 1 18* 160944 BEARING, piston, brass 1 19* 160945 SEAT, piston, reversible 1 20** 234578 PLATE, warning (with muffler) 1 21 183326 STOP, ball 1 22 191080 HOUSING, intake valve 1 24** 100078 . SCREW, hex washer hd, mach,
33† 160261 . NUT, adjusting 4 34† 160618 . WIRE, lock 2 35 172867 . ACTUATOR, valve 1 36† 160621 . O-RING, nitrile rubber 1 37 160623 . ARM, toggle 2 38 160624 . O-RING, nitrile rubber 1 39† 160625 . O-RING, nitrile rubber 1 40** 234577 . PLATE, identification,
with muffler 1 41 160639 . ROD, piston 1 42 160640 . NUT, packing 1 43 160641 . WASHER, backup 1 44* 160644 . PACKING, flat leather 1 45† 236079 . VALVE, poppet 2 46 160932 . GASKET, copper 1 47 161435 . NUT, cylinder cap 1 48* 162391 . V-PACKING, leather 5 49* 168851 . GLAND, male 1 50* 168852 . BEARING, throat 1 51 160613 . CYLINDER, air motor 1 53† 170709 . POPPET, valve, urethane 2 54 203965 . ROD, trip 1 55 204896 . BASE, air motor 1 57 102975 . SCREW, rd hd mach,
6–32 x 1/4” 2 58 172866 . CLIP, spring 2 59 15K534 . PISTON, air motor 1 60 116343 . SCREW, ground 1 63 162718 . ADAPTER, 3/8 npt (m) x
8–32 x 3/8” 12 25 101578 . CAPSCREW, hex hd Nylock,
* These parts are included in Pump Repair Kit 206925,
5/16–18 x 7/8” 6 27 156698 . O-RING, nitrile rubber 1 28 158360 . YOKE, rod, trip 1 29 158362 . PIN, toggle 2 30 158364 . PIN, pivot 2 31 167585 . SPRING, helical compression 2 32† 158367 . GROMMET; rubber 2
which may be purchased separately.
** These parts are included in Muffler Repair Kit 222559, which may be purchased separately.
† These parts are included in Air Motor Repair Kit 206728, which may be purchased separately.
1/4 npt(f) 1


Technical Data
Maximum Working Pressure 2700 psi (186 bar) Fluid pressure ratio 15:1 Air operating range 40 to 180 psi (3 to 12 bar) Air motor effective diameter 3 in. (76 mm) Stroke 3 in. (76 mm) Air consumption 17 cfm/gallon pumped at 100 psi
3/8 npt(f) Air Inlet
1/4 npt(f) Fluid Outlet
(0.476 m3/liter at 7 bar); up to 30 cfm with pump operated
at 180 psi and 66 cycles/min. (up to 0.84 m3/min with pump operated
at 12 bar and 66 cycles/min.) Pump cycles per gallon (liter) 90 (24) Delivery 0.66 gallons/minute (3 liters/minute) Maximum recommended pump speed 66 cycles/min;
Model 206405 13 inches (330 mm)
0.7 gpm (32 liter/min) Recommended speed for optimum pump life 15 to 25 cycles per min Wetted parts Carbon Steel, Brass, Copper, Aluminum, PTFE, Nitrile Rubber, Leather Approximate weight 22 lb (10 kg)
Model 206699 26.69 inches (677.7 mm)
Model 206700 33.62 inches (854 mm)
Mounting Hole Layout
2 Hole Mounting Pattern
4 Hole Mounting Pattern
Two or Four 0.265” (7 mm) Dia. Holes on 5” (127 mm) Bolt Circle
3” (76.2 mm) Dia.
161023 Gasket

Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or sub- stitution of non–Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
Graco makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment, materials or components sold but not manufactured by Graco. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnais- sent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés à la suite de ou en rapport, directement ou indirectement, avec les procedures concernées.
For the latest information about Graco products, visit www.graco.com
TO PLACE AN ORDER, contact your Graco distributor, or call one of the following numbers
to identify the distributor closest to you:
1–800–533–9655 Toll Free 612–623–6928 612–378–3590 Fax
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
This manual contains English. MM 306531
GRACO INC. P.O. BOX 1441 MINNEAPOLIS, MN 55440–1441 Copyright 1996, Graco Inc. is registered to ISO 9001
www.graco.com Revised 05/2009
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Pump fails to operate | Low air supply pressure or restricted air lines | Increase air supply; clear* | p.12 |
| Pump fails to operate | Closed valves | Open | p.12 |
| Pump fails to operate | Clogged fluid lines, hoses, valves, etc. | Clear* | p.12 |
| Pump fails to operate | Damaged air motor | Service air motor | p.12 |
| Pump fails to operate | Empty fluid supply container | Refill and reprime, or flush | p.12 |
| Continuous air exhaust | Worn or damaged air motor gasket, packing, seal, etc. | Service air motor | p.12 |
| Erratic pump operation | Empty fluid supply container | Refill and reprime, or flush | p.12 |
| Erratic pump operation | Held open or worn intake valve or piston packings | Clear; service | p.12 |
| Pump operates, but output is low on the up stroke | Held open or worn piston or packings | Clear; service | p.12 |
| Pump operates, but output is low on the down stroke | Held open or worn intake valve | Clear; service | p.12 |
| Pump operates, but output is low on both strokes | Low air supply pressure or restricted air lines | Increase air supply; clear* | p.12 |
| Pump operates, but output is low on both strokes | Closed valves | Open | p.12 |
| Pump operates, but output is low on both strokes | Empty fluid supply container | Refill and reprime, or flush | p.12 |
| Pump operates, but output is low on both strokes | Clogged fluid lines, hoses, valves, etc. | Clear* | p.12 |
| Pump operates, but output is low on both strokes | Packing nut too tight | Loosen | p.12 |
| Pump operates, but output is low on both strokes | Loose packing nut or worn packings | Tighten; replace | p.12 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.