EN
Graco logo
Official user manual

Graco PR70

50 pages·2.2 MB·Water Dispenser·PDF·ENDEFRITNLJA
Graco PR70
Table of Contents 80 sections Operation and Maintenance · PR70 · 312393J EN · PR70 Accessories · … ShowHide
Operation and Maintenancep.1PR70p.1312393J ENp.1PR70 Accessoriesp.3Supplied Manualsp.4PR70 Operationp.4Related Manualsp.4Installationp.7General Informationp.7Unpackingp.7Machine Setupp.7Locate and Install the PR70p.7Component Identificationp.8HMI Control and Indicatorsp.9HMI Main Run Screenp.10Run Screen Operationp.10Machine Operation: Operator Modep.10Machine Mode Selectionp.10Shot Number Selectionp.10Machine Operation: Shot Modep.10Machine Disable Mode (“p.11”red)p.11Setup Screens with Passwords Enabledp.11Setup Screensp.11Entering the Setup Screensp.11Machine Primingp.13Piston Position Calibration (C1)p.13Machine Calibrationp.13Phasing (C2)p.14Open Dispense Valve (ODV) Setting (C3)p.14Machine Calibration Shots (C4)p.15Shot Size Definition (M2)p.16Ratio Checksp.16Miscellaneous Machine Setupsp.17Manual Control Options (M1)p.17Purge Timer / Alarm Settings (M2)p.17Manual Piston Control:p.17Silent Mode Operation:p.18Cycle Counter and Silent Mode Control (M3)p.18Resetting the Cycle Counter:p.18Date and Time Settings (M4)p.19Tank Level Sensing and Velocity Change (“p.19”) Options (C6)p.19(C6)p.20= OFF,p.20= ONp.20= OFFp.20Password Setup / Clearing (C5)p.20Setting/Clearing an Administrative Password:p.20Resetting Passwordsp.21Setting/Clearing a Maintenance ONLY Password:p.21Miscellaneous Machine Featuresp.22HMI Hibernate Modep.22HMI Startup Animation Sequencep.22HMI Demo Mode Operationp.22Pressure Relief Procedurep.23Standby/Shutdown Procedurep.23Error Codesp.23Error Code Tablep.24Title # Cause, Details ICONp.24Maintenancep.28Run Tokenp.28Software Upgrades, Run Tokenp.28Troubleshootingp.29PROBLEM CAUSE SOLUTIONp.29Repairp.30Major Mechanical Assemblies, and Attachmentsp.30Base Frame Assemblyp.31Air Cylinder Assemblies, and Rebuild Kitsp.32NOTICEp.34Drive Block Assemblyp.35Pump Assemblies and Rebuild Kitsp.35Piston Cylinders or Metering Tubesp.38LCF - 120p.38LCE - 160p.38NYLON PISTONS (SEE FIGURE 50)p.39Hose Assembliesp.41Miscellaneous Mechanical Assembliesp.43Wiring Diagramsp.46Technical Datap.48
Page 1 of the Graco PR70 user manual — 312393J EN
Page 1 · click to enlarge
Page 1

Operation and Maintenance

PR70

™

2 Component Liquid Dispensing Systems PR70 All Models 3000 psi (21 MPa, 207 bar) Maximum Working Pressure 100 PSI (0.7 MPa, 7 bar) Maximum Air Inlet Pressure For Dispensing Multi-part Sealants and Adhesives. Not Designed for Use in Explosive Atmospheres.

312393J EN

Graco PR70 — 312393J EN diagram (page 1)
Fig. 1
Page 2 of the Graco PR70 user manual — Operation and Maintenance
Page 2 · click to enlarge
Page 2
Page 2 of the Graco PR70 user manual — Operation and Maintenance
Page 3 of the Graco PR70 user manual — PR70 Accessories
Page 3 · click to enlarge
Page 3

PR70 Accessories

Mixer and Shroud Options

LC0063 Mixer, 3/16 (6.5 mm) x 32, 10 Mixers with shroud LC0081 Mixer, 3/8 (9.8 mm) combo, 50 Mixers

LC0057 Mixer, ¼ (6.5 mm) x 24, 10 Mixers with shroud LC0083 Mixer, 1/4 (6.5 mm) x 24 Luer Lock, 50 Mixers

LC0058 Mixer, 3/8 (9.8 mm) x 24, 10 Mixers with shroud LC0082 Mixer, 3/16 (4.8 mm) x 32 Luer Lock, 50 Mixers

LC0059 Mixer, 3/8 (9.8 mm) x 36, 10 Mixers with shroud LC0084 Mixer, 3/16 (4.8 mm) x 32, 250 Mixers

LC0060 Mixer, 3/8 (9.8 mm) Combo, 10 Mixers with shroud LC0085 Mixer, 1/4 (6.5 mm) x 24, 250 Mixers

LC0061 Mixer, 3/16 (4.8 mm) x 32 Luer Lock, 10 Mixers with shroud LC0086 Mixer, 3/8 (9.8 mm) x 24, 250 Mixers

LC0062 Mixer, ¼ (6.5 mm) x 24 Luer Lock, 10 Mixers with shroud LC0087 Mixer, 3/8 (9.8 mm) x 36, 250 Mixers

LC0077 Mixer, 3/16 (4.8 mm) x 32, 50 Mixers LC0088 Mixer, 3/8 (9.8 mm) combo, 250 Mixers

LC0078 Mixer, ¼ (6.5 mm) x 24, 50 Mixers LC0089 Mixer, 3/16 (4.8 mm) x 32 Luer Lock, 250 Mixers

LC0079 Mixer, 3/8 (9.8 mm) x 24, 50 Mixers LC0090 Mixer, ¼ (6.5 mm) x 24 Luer Lock, 250 Mixers

LC0080 Mixer, 3/8 (9.8 mm) x 36, 50 Mixers

255217 MDS2, kit rebuild, air cylinder 255219 MD2, Soft Seat rebuild, needle and nose

255218 MD2, kit rebuild, back-end of wet section (no needle or seat) 255220 MD2, convert Soft Seat nose to Hard Seat (Hard Seat rebuild), needle and nose Other Accessories

LC0097 Desiccant Dryer, 3/8” NPT with adapter and cartridge LC0100 Vacuum Transfer Pump, 240V, down to 25 Torr

LC0098 Desiccant Dryer refill cartridge LC0091 3.0” Air Cylinder rebuild kit

LC0095 Nitrogen Kit for 30L and 60L tank, 1 tank LC0092 4.5” Air Cylinder rebuild kit

LC0096 Nitrogen Kit for 30L and 60L tank, 2 tanks LC0093 Check Valve rebuild kit

LC0008 Cord, I/O interface and footswitch part LC0094 Rear Pump Seal rebuild kit

LC0099 Vacuum Transfer Pump, 120V, down to 25 Torr

Models · MD2 Valve Kits

Page 4 of the Graco PR70 user manual — Related Manuals
Page 4 · click to enlarge
Page 4

Supplied Manuals

The following manuals will be supplied with the PR70.

PR70 Operation

Refer to these documents for detailed machine information.

PartDescription 312393Manual, Operation & Maintenance PR70 PR70 Feed System PartDescription 312394Manual, Tank/Feed System, PR70 Dispense Valve, MD2 PartDescription 312185Manual, Dispense Valve, MD2 * Heat Control Module(s) PartDescription 312413Manual, Heat Control, Tank/Hoses

Related Manuals

PR70 Operation PartDescription 312393Manual, Operation & Maintenance PR70 PR70 Feed System PartDescription 312394Manual, Tank/Feed System, PR70 Dispense Valve, MD2 PartDescription 312185Manual, Dispense Valve, MD2 Heat Control Module(s) PartDescription 312413Manual, Heat Control, Tank/Hoses

Manuals

Page 5 of the Graco PR70 user manual — Supplied Manuals
Page 5 · click to enlarge
Page 5
WARNING ELECTRIC SHOCK HAZARD Improper grounding, setup, or usage of the system can cause electric shock. • Turn off and disconnect power cord before servicing equipment. • Use only grounded electrical outlets. • Use only 3-wire extension cords. • Ensure ground prongs are intact on sprayer and extension cords. • Do not expose to rain. Store indoors. SKIN INJECTION HAZARD High-pressure fluid from dispense valve, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment. • Do not point dispense valve at anyone or at any part of the body. • Do not put your hand over the end of the dispense nozzle. • Do not stop or deflect leaks with your hand, body, glove, or rag. • Follow Pressure Relief Procedure in this manual, when you stop spraying and before cleaning, checking, or servicing equipment. TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. • Read MSDS’s to know the specific hazards of the fluids you are using. • Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines. • Always wear impervious gloves when spraying or cleaning equipment. FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion: • Use and clean equipment only in well ventilated area. • Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc). • Keep work area free of debris, including solvent, rags and gasoline. • Do not plug or unplug power cords or turn lights on or off when flammable fumes are present. • Ground equipment, personnel, object being sprayed, and conductive objects in work area. See Grounding instructions. • Use only Graco grounded hoses. • Check gun resistance daily. • If there is static sparking or you feel a shock, stop operation immediately. Do not use equipment until you identify and correct the problem. • Do not flush with gun electrostatics on. Do not turn on electrostatics until all solvent is removed from system. • Keep a working fire extinguisher in the work area.
Page 6 of the Graco PR70 user manual — Supplied Manuals
Page 6 · click to enlarge
Page 6
WARNING EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals. • Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS forms from distributor or retailer. • Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only. • Do not alter or modify equipment. • Use equipment only for its intended purpose. Call your distributor for information. • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. • Do not kink or over bend hoses or use hoses to pull equipment. • Keep children and animals away from work area. • Comply with all applicable safety regulations. MOVING PARTS HAZARD Moving parts can pinch or amputate fingers and other body parts. • Keep clear of moving parts. • Do not operate equipment with protective guards or covers removed. • Pressurized equipment can start without warning. Before checking, moving, or servicing equipment, follow the Pressure Relief Procedure in this manual. Disconnect power or air supply. PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, inhalation of toxic fumes, burns, and hearing loss. This equipment includes but is not limited to: • Protective eyewear • Clothing and respirator as recommended by the fluid and solvent manufacturer • Gloves • Hearing protection
Page 7 of the Graco PR70 user manual — Locate and Install the PR70
Page 7 · click to enlarge
Page 7

Installation

General Information

Verify the location has access to compressed air, AC power and is well ventilated.

Accessories are available from Graco. Make certain all accessories are adequately sized and pressure-rated to meet your system needs.

2. Place the PR70 onto the designated location. Allow to the machine to rest on the rubber feet provided.

Figures 2 thru 4 are only a guide for identifying system components and for assisting in installation. Contact your Graco distributor or Graco Ohio Customer Service for assistance in designing a system to suit your particular needs.

3. Turn the Shield Locking Screws clockwise on both sides to remove the PR70 protective shield.
4. Attach the PR70 frame to the selected location by installing fasteners (not provided with unit) thru the 4 mounting holes. Refer to Figure 1 for mounting hole dimensions.

Unpacking

1. Inspect the shipping container carefully for damage. Contact the carrier promptly if there is damage.

Machine Setup

2. Open the box and inspect the contents carefully. There should not be any loose or damaged parts in the container.

Avoid contact with electrical inter-connects, when connecting electric power to the machine. Read all manufacturer’s warning and material MSDS to know the specific hazards of the material used.

3. Compare the packing slip against all the items in the box. Report any shortage or other inspection problems immediately.
1. Connect a compressed airline to the input air in the back of the machine.
4. Remove the PR70 system components from the container. Do not lift the machine by the tanks.
2. Load material into the on-board or off-board tanks feeding the machine.

Locate and Install the PR70

3. Using the power cord provided, connect AC power (100-240V, 50/60 Hz, single-phase) to the machine.
1. Locate a bench top or equivalent location to mechanically mount the PR70 dispensing machine.
Graco PR70 — Locate and Install the PR70 diagram (page 7)
Fig. 2 · Locate and Install the PR70
Figure 1Mounting Hole Dimensions for Installing the PR70 Machine (dimensions in inches/mm)

Installation

Page 8 of the Graco PR70 user manual — Component Identification
Page 8 · click to enlarge
Page 8

Component Identification

Graco PR70 — Component Identification diagram (page 8)
Fig. 3 · Component Identification

Key: A Dispense Valve (DV) B HMI (Human Machine Interface) C Static Mixer D Shield Locking Screw E Power Switch F Air Filter G Customer Input Receptacle H Protective Shield I Air Pressure Regulator J Ball Valve (Optional) K A and B Tanks (Onboard, Polyethylene versions illustrated).

Figure 2Typical PR70 (Back View, without Hoses)
Graco PR70 — Component Identification diagram (page 8)
Fig. 4 · Component Identification

Key: A Pump Assembly B Solenoid Valves C Air Cylinder Assembly D DC Power Supply E Fluid Control Module (FCM)

Figure 3: PR70 Back View with Shield, Tanks, DV and HMI Removed.

Component Identification

Page 9 of the Graco PR70 user manual — HMI Control and Indicators
Page 9 · click to enlarge
Page 9
Graco PR70 — HMI Control and Indicators diagram (page 9)
Fig. 5 · HMI Control and Indicators

Key: A Drive Block B Hydracheck (optional) C Check Valve D Cylinder (Metering Tube) E Rear Bearing F Phase Adjustment Screw/Locking Nut G Mounting Hole in Base Frame

Figure 4: PR70 Top View with Shield, Tanks, DV and HMI Removed.

HMI Control and Indicators

Graco PR70 — HMI Control and Indicators diagram (page 9)
Fig. 6 · HMI Control and Indicators
Graco PR70 — HMI Control and Indicators diagram (page 9)
Fig. 7 · HMI Control and Indicators
Figure 5PR70 HMI Controls

Key: A Screen, Display Area B, D Up and Down Keys C Up and Down Key LED E Enter Key LED F Enter Key G-J Soft Keys 1 thru 4 (Left to Right). K Shot Mode ICON L Shot Mode LED M Mode Select Key

N Operator Mode ICON O Operator Mode LED P Red Stop or Cancel Key (used to stop machine operation) Q Lock Key (used to enter and exit setup screens) R Green Go Key (used to request a shot) S Display area T Diagnostic LED’s U HMI Rear Access Panel (used to access clock battery and for reprogramming the HMI).

Component Identification

Page 10 of the Graco PR70 user manual — Machine Operation: Shot Mode
Page 10 · click to enlarge
Page 10

HMI Main Run Screen

Graco PR70 — HMI Main Run Screen diagram (page 10)
Fig. 8 · HMI Main Run Screen
Graco PR70 — HMI Main Run Screen diagram (page 10)
Fig. 9 · HMI Main Run Screen
Figure 6Typical PR70 Main Run Screen (Shot and Operator Modes) Respectively)

Key: A Shot Number Field (“x” in Operator Mode) B Shot Size Field (“XXXXXX” in Operator Mode) C Shot weight/mass unit of measure (Grams). D Tank Fill Status Indicators E Pistons Status Field

F Cycle Counter G DV status Field H Purge Timer status Field I Error code status Field J Current Date Field (DD-MM-YY) K Current Time Field (24 Hr. Format)

Run Screen Operation

3. To cancel the shot, press

Machine Operation: Operator Mode

Read all manufacturer’s warning and material MSDS to know the specific hazards of the material used.

1. Place the item or part to be filled below the dispense valve static mixer.

Machine Mode Selection

2. Press and hold

(green) or the footswitch to start the shot. The machine will continue to dispense

To dispense material, one of the following 2 modes must be selected;

(green) or the footswitch is released.

  • Shot mode dispenses a predetermined amount of material when the machine receives a “Go” command.

The pistons will not retract unless they are almost fully extended. They will automatically retract after 4 minutes. The machine will beep to signal that it is about

  • Operator mode dispenses material as long as the machine is receiving a “Go” command.

to retract. To manually retract the machine, press

To select Shot mode:

Shot Number Selection

1. Press

In Shot mode, up to 5 predefined shot sizes may be selected. To select a shot:

2. Press

to cancel.

1. When the machine is idle (not dispensing a shot)

To select Operator mode:

to select the new shot size.

3. Press
2. Press

to cancel.

4. Press

to cancel.

Machine Operation: Shot Mode

1. Place the item or part to be filled below the dispense valve static mixer
2. Press

(green) or the footswitch to start the shot.

Show 9 more labels / short text on this page
Run Screens · until the · until · to accept or · press · or · until · to accept, or · to accept or
Page 11 of the Graco PR70 user manual — Entering the Setup Screens
Page 11 · click to enlarge
Page 11

Disable Mode, Entering Set-up Screens

2. To enter the calibration screens, press

. To

Machine Disable Mode (“

”red)

enter the maintenance screens, press

. Refer to Figure 9 for a screen navigation diagram.

Graco PR70 — Machine Disable Mode (“ diagram (page 11)
Fig. 10 · Machine Disable Mode (“

Setup Screens with Passwords Enabled

1. From the Run screen press

. If a password has been programmed, the Password Entry Screen (Figure 8) will be displayed.

Figure 6Typical Run Screen when Machine in
Graco PR70 — Setup Screens with Passwords Enabled diagram (page 11)
Fig. 11 · Setup Screens with Passwords Enabled
1. At any time and from any screen, to immediately

disable all machine motion, press

(red).

2. If activated, the purge timer will be disabled
3. To resume operation, the machine must be put back into an operating mode as described in the Machine Mode Selection section.
Figure 8Password Entry Screen
4. If activated, the purge timer will not restart until a shot is taken.
2. Enter the 6 digit password by pressing the corresponding soft keys, G-J in Figure 5.
3. After the 6 th digit has been entered, press

Setup Screens

4. If the correct password has been entered, the Programming Mode Selection Screen will be displayed. Refer to Figure 9 for a screen navigation diagram.

Before the machine will operate properly, it must be calibrated and shot size information must be entered.

Entering the Setup Screens

5. If the incorrect password has been entered, the password entry will need to be repeated until the correct 6-digit sequence is entered.
1. From the Run screen press

. If no password has been programmed into the HMI, the Programming Mode Selection Screen (Figure 7) will be displayed.

6. To abort the password entry, press
Graco PR70 — Entering the Setup Screens diagram (page 11)
Fig. 12 · Entering the Setup Screens
Figure 7Programming Mode Selection Screen

“Disable” Mode

Page 12 of the Graco PR70 user manual — Machine Disable Mode (“
Page 12 · click to enlarge
Page 12
Graco PR70 — Machine Disable Mode (“ diagram (page 12)
Fig. 13 · Machine Disable Mode (“
Figure 9PR70 Screen Navigation Diagram

Screen Layout

Page 13 of the Graco PR70 user manual — Machine Calibration
Page 13 · click to enlarge
Page 13

Machine Priming

Before the machine can be properly calibrated with material, it will need to be primed.

Be careful not to pinch fingers when manually moving the machine drive block.

Piston Position Calibration (C1)

Read all manufacturer’s warning and material MSDS to know the specific hazards of the material used.

This step should be executed the 1st time the machine is setup, and may not need to be re-executed unless the position sensor, an electronic component or a piston has been replaced.

From the Run Screen press

. The following screen will be displayed.

Graco PR70 — Piston Position Calibration (C1) diagram (page 13)
Fig. 14 · Piston Position Calibration (C1)

From the Run Screen press

. The following screen will be displayed.

Graco PR70 — Piston Position Calibration (C1) diagram (page 13)
Fig. 15 · Piston Position Calibration (C1)
Figure 11Piston Position Calibration Screen (C1)

Key: A Full Extend position number from last calibration B Full Extend Command ICON C Full Retract position number from last calibration D Full Retract Command ICON E Cylinder Entrance position from last calibration F Cylinder Entrance Command ICON H Current Piston Position Field I Screen Number (C1)

Figure 10Maintenance Screen for Priming (M1)
KeyA Full Retract ICON B Full Extend ICON C Change Dispense Valve Mode

= Opens at Cylinder Entrance (Automatic) D Current Piston Position E Current Dispense Valve Mode F Screen Number (C1)

J

keys will navigate to adjacent screens.

1. Place a waste container under the dispense valve to capture any dispensed material.

G

keys will navigate to adjacent screens.

2. With air pressure applied to the machine, press
1. Place a waste container under the dispense valve to capture any dispensed material.
3. The piston should fully extend and a number between 3600 to 3900 should appear for ‘H’
2. Press

until the upper ICON is

4. Press

to keep the current number.

to accept the number or

3. Press

to extend the piston fully.

5. Press
4. Press

to retract the piston fully.

6. The piston should fully retract and a number between 1250 to 1600 should appear for ‘H’.
5. Repeat steps 3 and 4 until both materials dispense from the valve without air.
7. Press

to keep the current number.

to accept the number or

6. Press

twice to return to the Run screen.

8. Decrease the air pressure by adjusting the machine air pressure regulator to a minimal value (i.e. ~ 10 - 20 psi).

Machine Calibration

Before the machine will accurately dispense, it must be calibrated.

9. Press
Show 7 more labels / short text on this page
Priming and Calibration · then press · then press · = Always Open · = Always Closed · & · &
Page 14 of the Graco PR70 user manual — J
Page 14 · click to enlarge
Page 14
10. The machine pistons should extend slowly until they encounter the cylinder entrance and a number between 2000 to 2400 should appear for ‘H’.
1. Select the location where the piston will reverse

(from the extend to retract motion) by pressing

keys. Pressing

will decrease the phasing

11. If the pistons do not move, manually move the piston by pulling on the machine drive block, until mechanical resistance is encountered at the cylinder entrance.

shot. Pressing

will increase the phasing shot. A “+” value indicates that the piston will reverse beyond the cylinder entrance. A “-“ value indicates the piston will reverse prior to reaching the cylinder entrance.

12. Press

to keep the current number.

to accept the number or

2. Press

(green) or the footswitch.

3. During the shot execution, visually monitor the 2 materials exiting the ratio check nozzle. If the timing of the 2 materials exiting the nozzle cannot
13. Adjust the Air Pressure Regulator back to a reasonable value for proper machine operation.
14. Press

twice to return to the Run screen.

be properly observed, press

accordingly, then repeat step 2.

Phasing (C2)

4. If the A side material exits the ratio nozzle before

To enable the machine to dispense the correct ratio of material from the A and B tanks and to mix properly, both materials will need to enter the static mixer at the same time. Phasing shots will need to be executed to visually verify that the 2 materials are exiting the dispense valve at the same time.

the B side material (“

”), turn the B piston Phase Adjustment Screw/ Locking nut and shaft counterclockwise to move the B piston forward, as

ICON. Slight adjustments in the piston shaft will be significant. Adjustments of a quarter turn are typical.

Remove any static mixer attached to the dispense valve, and replace it with a ratio check nozzle. Place a waste container under the valve to capture any dispensed material.

5. If the B side material exits the ratio nozzle before

the A side material (“

”), turn the A piston Phase Adjustment Screw/ Locking nut and shaft counterclockwise to move the A piston forward, as

From the Run screen, press

once. The following will screen will be displayed.

Graco PR70 — Phasing (C2) diagram (page 14)
Fig. 16 · Phasing (C2)

ICON.

6. Repeat step 2 until both materials exit the ratio

check nozzle at the same time (“

”).

7. Press

twice to return to the Run screen.

Open Dispense Valve (ODV) Setting (C3)

The next step in the calibration process is to determine the proper position to open the Dispense Valve (DV) during the shot.

Figure 12Phasing Calibration Screen (C2)

Key: A A material leads B ICON B Adjust B side Forward ICON C B material leads A ICON D Adjust A side Forward ICON E A and B Exit the Same Time ICON F Do NO Mechanical Adjustment ICON G Phase Shot Request ICON I Screen Number (C2)

Advancing or increasing the opening position (in milli- meters) will build more pressure in the material hoses prior to the dispense valve opening. If the Dispense Valve opens too late in the shot, a surge of material can occur or the piston could stall. If the Dispense Valve opens to early in the shot, material “drooling” at the beginning of the dispense cycle could occur.

From the Run screen, press

J

keys will navigate to adjacent screens. K Decrease Phase Shot Percentage Amount ICON L Current Phase Shot Percentage Amount M Increase Phase Shot Percentage Amount ICON

2 times. The following screen will be displayed.

Show 12 more labels / short text on this page
Priming and Calibration · or · or · indicated on the · , then press · , and then · press · indicated on the · , then press · , and then · & · press
Page 15 of the Graco PR70 user manual — Machine Calibration Shots (C4)
Page 15 · click to enlarge
Page 15
Graco PR70 — Machine Calibration Shots (C4) diagram (page 15)
Fig. 17 · Machine Calibration Shots (C4)

From the Run screen, press

3 times. The following screen will be displayed.

Graco PR70 — Machine Calibration Shots (C4) diagram (page 15)
Fig. 18 · Machine Calibration Shots (C4)
Figure 13Open Dispense Valve (ODV) Screen (C3)
KeyA Current ODV Adjustment (in mm from the cylinder
Figure 14Stroke Calibration (CAL) Screen (C4)

entrance). B Adjust ODV value Option ICON. C Relative ODV Position ICON with respect to

Key: A Short Shot Column ICON B Last/Current Short Shot weight (mass) entry. C Long Shot Column ICON D Last/Current Long Shot weight (mass) entry. E Grams (Weight or Mass unit used) F Short Shot ICON G Long Shot ICON I Screen Number (C4)

cylinder entrance (This ICON will move right or left at +/- mm transition). D Cylinder Entrance ICON (stationary). I Screen Number (C3)

J

keys will navigate to adjacent screens.

1. To adjust the ODV position with respect to the

J

keys will navigate to adjacent screens.

1. Press

to arm the machine to take a short CAL

2. Press

to decrease the value. Values of – 5.0 mm to + 5.0 mm are allowed.

to increase the value or

shots. The icon will be highlighted (“

”). Press

to de-arm the machine.

3. Press

to retain the previous value. The default value from the factory is – 1.0 mm.

to accept the value or

2. Place the empty container below the static mixer,

(green) or the footswitch.

3. Press

and discard the contents of the material dispensed

4. Press

twice to return to the Run screen.

Machine Calibration Shots (C4)

4. Repeat the previous 2 steps until the static mixer is filled with material. Verify the material dispensed from the mixer is mixed properly.
5. Place a container on a scale and tare (zero) it.

Read all manufacturer’s warning and material MSDS to know the specific hazards of the material used.

6. Place the tared container below the static mixer,

(green) or the footswitch.

Calibration shots are necessary to program the machine to properly dispense the correct amount of

7. Press

to erase existing average weight data.

material. Several short CAL shots (“

8. Place the container with the dispensed material on the tared scale.

long CAL shots (“

”) are required.

Remove the ratio check nozzle, install the static mixer intended to be used, and adjust the air pressure to the level intended for use during normal operation.

9. Enter the mass in grams into the HMI, by pressing

accordingly.

The air pressure must be set to operating conditions for this step. Significant changes in air pressure could adversely affect shot accuracy.

10. Press

to accept the number. The number entered will be transferred to the right of the average icon (“

”).

11. Repeat steps 5 through 10, skipping step 7, several times. Each additional shot weight will be averaged in the

row with the previous shots.

Show 10 more labels / short text on this page
Priming and Calibration · , then press · , then press · & · & · cylinder entrance, press · and press · and press · ”) and several · or
Page 16 of the Graco PR70 user manual — Ratio Checks
Page 16 · click to enlarge
Page 16

I Screen Number (M2).

12. Press

to arm the machine to take a long CAL

J

keys will navigate to adjacent screens.

shots. The icon will be highlighted (“

”). Press

to de-arm the machine.

1. Press

. The following screen will be displayed:

13. Place a container on a scale and tare (zero) it.
Graco PR70 — J diagram (page 16)
Fig. 19
14. Place the tared container below the static mixer,

(green) or the footswitch.

15. Press

to erase existing average weight data.

16. Place the container with the dispensed material on the tared scale.
Figure 16M2 Shot Definition Screen
17. Enter the mass in grams into the HMI, by pressing

accordingly.

2. Press

to select a shot number to define.

18. Press

to accept the number. The number entered will be transferred to the right of the average icon (“

3. Press

to enter the shot size.

”).

The shot size (in grams) must be greater than the Short CAL Shot size from the previous C4 calibration screen.

19. Repeat steps 13 through 18, skipping step 15, several times. Each additional shot weight will be averaged in the

row with the previous shots.

4. Press

to retain the previous value.

to accept the value or

20. Press

to de-arm the cal shot.

5. Repeat the previous 2 steps for other shot sizes as required.
21. Press

twice to return to the Run screen.

Shot Size Definition (M2)

6. Press

to exit the Shot Definition screen.

To dispense in Shot Mode, one or more, up to 5, shot sizes need to be entered. This step is not required for Operator mode.

7. Press

twice to return to the Run screen.

Ratio Checks

From the Run screen, press

once. The following screen will be displayed.

Graco PR70 — Ratio Checks diagram (page 16)
Fig. 20 · Ratio Checks

Read all manufacturer’s warning and material MSDS to know the specific hazards of the material used.

This is a procedure to verify the weight ratio between the 2 materials. This is easiest to do with two scales.

1. From the Run screen, put the machine in Shot

”). See page 13.

2. Verify that the machine is properly calibrated and phased as outlined in the calibration section.
3. Remove any static mixer attached to the dispense valve and replace it with a ratio check nozzle. Place a waste container under the valve to capture any dispensed material.
Figure 15Shot Size and Purge Timer Screen (M2)

Key: A Shot Number B Shot Size (in grams). C Purge Timer Setting (Turned OFF in Figure 15). D Purge Timer Alarm Setting. E Define Shot ICON F Set Purge Timer ICON G Purge Timer Warning ICON.

4. Select a shot size between the Short and Long CAL

shot sizes previously done, by pressing

to accept.

5. Place the empty container below the Ratio Check Nozzle and the footswitch. Discard this shot.
Show 12 more labels / short text on this page
Priming and Calibration · & · and press · or · or · or · , then press · , and then · press · mode (“ · or · and
Page 17 of the Graco PR70 user manual — Manual Piston Control:
Page 17 · click to enlarge
Page 17
6. Place an empty container on a scale, and tare (zero) the scale. Repeat the process with a 2 nd container on a 2 nd scale.
9. After the material is dispensed, place each container on the same scale, and measure the net mass of each of the materials. Record the mass of both the A and B materials.
7. Place both containers under the ratio check nozzle, positioned so one container captures material A, and the 2 nd container captures material B.
10. Divide the A material mass by the B material mass to obtain the material ratio being dispensed.
8. Press the footswitch.

Miscellaneous Machine Setups

The following sections outline how to configure various optional settings.

Manual DV Control:

1. To change the DV operation press the third blue key from the left.

Manual Control Options (M1)

2. When the Current Dispense Valve Mode (E in

The user can control the machine’s piston position and displacement valve operation manually the M1 screen.

, the valve will open and stay open regardless of the piston position.

From the Run Screen press

. The following screen will be displayed.

3. When the Current Dispense Valve Mode is

, the valve will close and stay closed regardless of the piston position.

4. When the Current Dispense Valve Mode is

, the valve will be in automatic mode, opening when the pump gets to the cylinder entrance and closing when it gets to the end of the cylinder.

5. Press

twice to return to the Run screen.

Purge Timer / Alarm Settings (M2)

When activate, the Purge Timer will automatically dispense a shot if the machine is idle (not dispensing material) for a programmed duration of time. This prevents the mixed material from hardening in the static mixer. To set the Purge Timer;

Figure 17Maintenance Screen (M1)
KeyA Full Retract ICON B Full Extend ICON C Change Dispense Valve Mode

From the Run screen, press

once. The following screen will be displayed.

Graco PR70 — Purge Timer / Alarm Settings (M2) diagram (page 17)
Fig. 21 · Purge Timer / Alarm Settings (M2)

= Opens at Cylinder Entrance (Automatic) D Current Piston Position E Current Dispense Valve Mode F Screen Number (C1)

G

keys will navigate to adjacent screens.

Manual Piston Control:

Figure 18M2 after Purge Timer Selection
1. Press
1. Press

to extend the piston.

2. Press

to enter the purge timer value. This idle time allowed before the machine will automatically dispense a shot to clear the mixer.

2. Press

to retract the piston.

Show 10 more labels / short text on this page
Priming and Calibration · Figure 17) is · then press · , then press · , and then · press · = Always Open · = Always Closed · & · or
Page 18 of the Graco PR70 user manual — Cycle Counter and Silent Mode Control (M3)
Page 18 · click to enlarge
Page 18
3. Press

to retain the previous value.

to accept the value or

From the Run screen, press

2 times. The following screen will be displayed.

Graco PR70 — Silent Mode Operation: diagram (page 18)
Fig. 22 · Silent Mode Operation:
Graco PR70 — Silent Mode Operation: diagram (page 18)
Fig. 23 · Silent Mode Operation:
Figure 19M2 after Purge Shot Size Prompt
4. Press

to enter the purge shot size (in grams). Enter a number with at least as much volume as the mixer.

Figure 21M3 Cycle Counter and Silent Mode Control

Key: A Total Pump Cycle Counter Value (Not Resettable) B Resettable Cycle Counter Value C Current Silent Mode State ICON

5. Press

to retain the previous value.

to accept the value or

6. Press

twice to return to the Run screen.

Silent Mode On D Reset Cycle Counter ICON E Toggle Silent Mode ICON. I Screen Number (M3)

Activating the purge timer automatically activates the

. This is the amount of time before the purge timer reaches zero that the machine will sound a warning beep to signaling that it is about to take a purge shot. To change the Purge Alarm value;

J

keys will navigate to adjacent screens.

1. Press

From the Run screen, press

2. Press

to retain the previous value.

to accept the value or

once. The following screen will be displayed.

Graco PR70 — J diagram (page 18)
Fig. 24
3. Press

twice to return to the Run screen.

Silent Mode Operation:

The default setting is

, Silent Mode Off, where audio feedback is provided when a valid key (1 short tone), or an invalid key (3 short tones) is pressed.

Figure 20M2 after Purge Alarm Selection

, Silent Mode On, audio feedback is not provided. Silent Mode On has no effect on the audio sounds provided for the purge timer alarm, an error code, or when power is initially applied to the machine.

1. Press
2. Press

to enter the purge alarm duration (in seconds). The minimum value is 2 seconds, and a maximum of 59 seconds or the value of the purge timer if the timer is more than 59 seconds.

To toggle or change the silent mode:

From the Run screen, press

2 times. Screen M3, see Figure 21, will be displayed.

3. Press

to retain the previous value.

to accept the value or

1. Press
4. Press

twice to return to the Run screen.

2. Press

to retain the previous setting.

to accept the change or

Cycle Counter and Silent Mode Control (M3)

Resetting the Cycle Counter:

3. Press

twice to return to the Run screen.

The cycle counter shown on the Run screen, see Figure 6, shows the number of pump cycles since the last time the cycle counter was reset. To reset the cycle counter:

Show 17 more labels / short text on this page
Miscellaneous Machine Setups · , then press · , and then · press · or · Silent Mode Off · purge alarm · & · , then press · , and then · press · In · or · , then press · , and · then press · or
Page 19 of the Graco PR70 user manual — J
Page 19 · click to enlarge
Page 19

Date and Time Settings (M4)

1. Press

. The M4 screen will appear as follows.

At the bottom right corner of the Run screen the date is shown in DD-MM-YY format and the time is shown in HH:MM, 24 hour format. The formats cannot be changed.

Graco PR70 — Date and Time Settings (M4) diagram (page 19)
Fig. 25 · Date and Time Settings (M4)

To set the current date:

From the Run screen, press

3 times. The following screen will be displayed.

Figure 25M4 after Time Set Selection
Graco PR70 — Date and Time Settings (M4) diagram (page 19)
Fig. 26 · Date and Time Settings (M4)
2. Press

to enter the hour (0 - 23).

3. Press

to retain the previous setting.

to accept the change or

4. Press

to enter the minutes (0 - 59).

Figure 23: M4 Screen for Setting the Date and Time Key: A Current Date (DD-MM-YY) B Current Time (HH:MM, 24 Hour Format) C Current Software Revision

5. Press

to retain the previous setting.

to accept the change or

6. Press

twice to return to the Run screen.

Tank Level Sensing and Velocity Change (“

Dsp = Display Module FCM = Fluid Control Module D Date Set ICON E Time Set ICON. I Screen Number (M4)

”) Options (C6)

If tank level sensors are installed into the system, an alarm is generated when a tank is almost empty. If the

feature is turned ON, a Tank A low (“

”), a Tank B

J

keys will navigate to adjacent screens.

”) error will be generated if the condition exists.

”), or a both tanks are low (“

1. Press

. The M4 screen will appear as follows.

The machine also measures the piston velocity and will generate an alarm if the piston velocity has changed significantly since the machine was last calibrated. A significant change is piston velocity, usually caused by a change in air pressure, can degrade shot size accuracy.

Graco PR70 — J diagram (page 19)
Fig. 27
Figure 24M4 Screen after Date Set Selection

The user has the capability to turn the

by selecting a level of 0%, or ON by selecting

levels of 20%, 40% or 60%. For instance, if 40% is selected, and the piston velocity changes by + or – 40%, an error code will be generated after the corresponding shot to inform the operator of the situation. If the velocity

3. Press

to enter the year.

4. Press

to retain the previous setting.

to accept the change or

increases above the selected level, a

error will be generated, and if the velocity decreases below the

5. Press

to enter the month.

6. Press

to retain the previous setting.

to accept the change or

error will be generated.

feature is automatically disabled when the machine is in Operator mode, or when the machine is executing a purge shot.

7. Press

to enter the day.

8. Press

to retain the previous setting.

to accept the change or

From the Run screen, press

9. Press

twice to return to the Run screen.

5 times. The following screen will be displayed.

To set the current time:

Show 16 more labels / short text on this page
Miscellaneous Machine Setups · , then press · , and then · press · and · and · & · low (“ · feature OFF · and · and · selected level a · The · and · , then press · , then press
Page 20 of the Graco PR70 user manual — Setting/Clearing an Administrative Password:
Page 20 · click to enlarge
Page 20
Graco PR70 — (C6) diagram (page 20)
Fig. 28

Level ICON I Screen Number (C6)

J

keys will navigate to adjacent screens.

To turn the Tank Level Sensors On/Off:

1. Press
2. Press

to retain the previous setting.

to accept the change or

Figure 26Tank Level and

(C6)

3. Press

twice to return to the Run screen.

KeyA Current Tank Level Mode

To turn the Velocity Change On/Off:

= OFF,

= ON

1. Press
2. Press

to retain the previous setting.

to accept the change or

= OFF

= 20% change before warning

3. Press

twice to return to the Run screen.

= 40% change before warning

= 60% change before warning D Turn ON / OFF Tank Level Sensing ICON

Graco PR70 — = OFF diagram (page 20)
Fig. 29

Password Setup / Clearing (C5)

The machine has the capability to limit access to the Maintenance and Calibration screens. The password option can be configured into 1 of the following 3 possibilities:

a. No Password (default configuration, when machine

shipped): All users can access all setup screens to configure the system.

Figure 29C5 Screen with at least 1 Password

Configured Key: A Administrative Password ICON B Access Indicator for Administrative Password D Entry Status (Only filled after password change). E Maintenance ONLY Password ICON F Access Indicator for Maintenance ONLY Password G Administrative Password Set/Clear ICON H Maintenance ONLY Password Set/Clear ICON I Screen Number (C5)

b. One password (“

”)Allows access to both the

maintenance and calibration screens (

).

c. Two passwords. One password allows access to

both the calibration and maintenance screen (

). The second password only allows

access to the maintenance screens (

).

To alter the password configuration:

J

keys will navigate to adjacent screens.

From the Run screen, press

4 times. The following screen will be displayed.

Setting/Clearing an Administrative Password:

1. Press

. The following screen will appear.

Show 14 more labels / short text on this page
Miscellaneous Machine Setups · E Change · & · or · B Current · level · + · = · + · = · & · , then press · , and then · press
Page 21 of the Graco PR70 user manual — Setting/Clearing a Maintenance ONLY Password:
Page 21 · click to enlarge
Page 21
Graco PR70 — Resetting Passwords diagram (page 21)
Fig. 30 · Resetting Passwords
3. Press

to accept.

4. Re-enter the same 6-digit number.
5. Press

to accept.

6. If both 6-digit passwords match, the C5 screen will be displayed, and an “OK” after the second row of symbols. If the 2 numbers do not match, the process will need to be repeated.
Figure 30Administrative Password Entry with NO
7. Press

twice to return to the Run screen.

If a previous Administrative password has been entered, the number at the top of the screen is the existing password. A zero indicates no Administrative password. To clear the password, enter “000000”.

With a Maintenance ONLY password, after the user enters the password from the Password Entry screen, the following screen will be displayed.

Graco PR70 — Resetting Passwords diagram (page 21)
Fig. 31 · Resetting Passwords
2. Enter a 6-digit sequence, by pressing the corresponding soft keys, G-J in Figure 5. After the 6th key entry, the enter LED will blink.
3. Press

to accept.

Figure 32Mode Selection Screen after
4. Re-enter the same 6-digit number.

Maintenance ONLY Password Entry

5. Press

to accept.

6. If both 6-digit passwords match, the C5 screen will be displayed, and an “OK” after the first row of symbols. If the 2 numbers do not match, the process will need to be repeated.

Resetting Passwords

If for whatever reason, the passwords for the machine are not known, the passwords can be reset.

To reset all the passwords to 000000:

7. Press

twice to return to the Run screen.

1. Temporarily remove power to the HMI.

Setting/Clearing a Maintenance ONLY Password:

2. Re-apply power to the HMI.
3. Immediately after the completion of the startup
1. Press

. The following screen will appear.

, ….), press and hold the second soft key for at least 6 seconds.

Graco PR70 — Setting/Clearing a Maintenance ONLY Password: diagram (page 21)
Fig. 32 · Setting/Clearing a Maintenance ONLY Password:

If the press and hold does not start immediately after the animation sequence, or the press and hold is interrupted, the procedure will need to be restarted at step 1.

4. After 6 seconds, the HMI will generate a single tone indicating that the passwords have been cleared.
Figure 31Maintenance ONLY Password Entry with
5. New passwords may be entered by following the steps in Password Setup / Clearing.

NO Previous Password Stored

If a previous Maintenance Only password has been entered, the number at the top of the screen is the existing password. A zero indicates no Administrative password.

To clear the password, enter “000000”.

2. Enter a 6-digit sequence, by pressing the corresponding soft keys, G-J in Figure 5. After the 6th key entry, the enter LED will blink.
Show 7 more labels / short text on this page
Password Setting/Clearing · Previous Password Stored · sequence ( · , · , · , · ,
Page 22 of the Graco PR70 user manual — HMI Demo Mode Operation
Page 22 · click to enlarge
Page 22

Hibernate and Demo Modes

If the press and hold does not start immediately after the animation sequence, or the press and hold is interrupted, the previous and this step may need to be repeated.

Miscellaneous Machine Features

HMI Hibernate Mode

To help preserve the life of the HMI backlight, the HMI will enter a Hibernate mode after the machine has remained idle for an extended period of time. To exit Hibernate mode, the user simply needs to activate a HMI key or the machine footswitch.

4. After 6 seconds, the HMI will generate a single tone and the Demo Mode ON or OFF state will be changed.
5. When in Demo Mode, a “D” will remain on the bottom left-hand corner of the Run screen, as indicated in the following figure.

When in Hibernate mode, the HMI LCD backlight will be turned OFF, and the enter LED will blink at a slow duty cycle (1 part ON, 8 parts OFF).

Graco PR70 — HMI Hibernate Mode diagram (page 22)
Fig. 33 · HMI Hibernate Mode

If the machine performs a purge shot when the HMI is hibernating, the HMI will remain in Hibernate mode.

HMI Startup Animation Sequence

When power is applied to the machine, the electronics need time to initialize communication. An “Hour Glass” animation sequence is generated

Figure 33Typical Run Screen in Demo Mode

, ….). Attempts to use the machine during the startup period will be rejected.

6. To switch the HMI out of Demo Mode, repeat the previous steps.

HMI Demo Mode Operation

Limitations of Demo Mode Simulation

The machine HMI is equipped with a demonstration mode. When in “Demo Mode”, the HMI will not send any requests to the Fluid Control Module and the machine will not operate. The HMI will simulate normal operation and provide audio feedback to the user. All Demo Mode Maintenance and Calibration screens are identical to screens provided in normal mode operation.

Even though Demo Mode provides a good training simulation for the user, it does have limitations when compared to the HMI operating in normal mode.

  • On the Run screen, all the shot mode shots are simulated as single piston stroke shots regardless of the shot size and calibration numbers entered.

Demo Mode can be used as a training tool for the user. The user simply has to connect the HMI unit to a separate power supply module, and the HMI will operate normally without the machine attached.

  • The run screen animation sequence of the piston movement is not as gradual as in real operation.
  • On the Run screen, during Operator mode operation, a stalled piston condition is not simulated.

Any calibration, passwords, shot sizes, purge timer settings, or other miscellaneous settings entered while operating in Demo mode WILL NOT alter any normal mode settings. Also, the first time Demo mode is entered, all the calibration & maintenance screen setups previously described will need to be repeated.

  • The piston cycle counter is not stored for use after power interruption, so if power is cycled to the HMI, the cycle count will be reset.
  • The piston position numbers provided on the C1 screen are simulated.

To configure the HMI into and out of Demo Mode:

  • All error codes will be NOT be generated, except a stuck key error (E11) if the condition exists.
1. Temporarily remove power to the HMI.
2. Re-apply power to the HMI.
3. Immediately after the completion of the startup

, ….), press and hold the first soft key for at least 6 seconds.

Show 10 more labels / short text on this page
( · , · , · , · , · sequence ( · , · , · , · ,
Page 23 of the Graco PR70 user manual — Error Codes
Page 23 · click to enlarge
Page 23

Pressure Relief and Shutdown Procedures, Error Codes

Graco PR70 — Pressure Relief Procedure diagram (page 23)
Fig. 34 · Pressure Relief Procedure

Pressure Relief Procedure

With the machine in an idle state:

1. If the machine pistons are not fully retracted,

retract the pistons by pressing

in the M1 screen. See Figure 17.

2. Manually open the dispense valve by pressing

the third M1 soft key until the “

” ICON is shown in the Current DV field. See Figure 17.

Figure 34Typical Error Code Screen
3. Remove the incoming air pressure by closing the air inlet valve (item 13 in Figure 54).

Key: A Error Code Animation Field B Error Code Number Field D Error Code ICON E Error Code Acknowledgement ICON

Standby/Shutdown Procedure

If the machine is to remain idle for an extended period of time, implement the following:

When an error code is generated, the user will need to acknowledge the condition by pressing the soft key

1. Remove any static mixer installed at the end of the dispense valve.

ICON.

2. Place a container below the valve, and activate a small shot to flush material away from the end of the valve.

After the user activates the

key, the error number generated in the Figure 34 example, will be displayed on the bottom left hand corner of the Run screen, while the condition is still present.

3. To prevent accidental pump movement, press
Graco PR70 — Standby/Shutdown Procedure diagram (page 23)
Fig. 35 · Standby/Shutdown Procedure

(red).

4. With a clean rag, clean the end of the dispense valve to remove excess material.
5. Install a nightcap at the end of the valve.

Error Codes

Figure 35Typical Run Screen with an Active

When the machine is operating and a fault is detected, it will report the condition by generating an error code. Error codes are typically generated when the machine is idle after dispensing a shot.

The example E12 number on the main run screen will remain on the run screen as long as the error condition exists. If the problem is corrected the example E12 number will be removed.

When error codes are generated, a screen will be displayed which contains an animation sequence, the error code number and an ICON symbol representing the condition detected. The HMI will also output an error code tone sequence. The tone sequence cannot be disabled.

If more than 1 error code condition exists for the machine, the corresponding “EXX” numbers will be listed on the bottom left corner, separated by commas.

When errors are generated, the machine will automatically be disabled and remain in an idle state until the user acknowledges the condition. Any active purge timer present prior to error code generation will be suspended, and will need re-started by requesting a shot after the error is acknowledged.

The following typical screen is generated when an error code is generated:

under the · Error Code Condition

Page 24 of the Graco PR70 user manual — Title # Cause, Details ICON
Page 24 · click to enlarge
Page 24

Error Code Table

Title # Cause, Details ICON

Stuck Key Error E11 A key on membrane has been active (pressed) for > 30 seconds continuously. Replace the HMI. This error code does not require user acknowledgment and will clear itself automatically if the condition is removed.

E12 The Display module has lost communication with the Fluid Control Module. Material dispensing will be disabled if this condition exists. Check communication cables between the 2 electronic components, or check the HMI and/or the Fluid Control Module.

This error will be regenerated continuously while the condition exists.

No or Invalid Run Token Error

E13 The Run Token in the FCM is missing (not installed), or does not have the correct data.

Piston Stroke Time-out Error

E21 A piston stroke action has taken > 55 seconds. Typically caused by no/too little air pressure to the machine or a mechanical interference with the piston has occurred. Check machine input line pressure.

Less than Minimum Shot Requested Error

E23 User has requested a shot < the minimum allowable size entered during calibration. (< 15% of stoke, N/A in Operator Mode).

E24 The calibration done on the machine is invalid, so the requested shot cannot be executed. For instance, a Large Stroke Calibration Shot mass which is less than the Short Stroke Calibration Shot mass (C4 screen) will create this error code. If the wiring to the linear position transducer is reversed this error will appear. If invalid piston positions are calibrated into the machine (C1 screen) this error will appear.

Delta Velocity (“V”) Minus Error

E25 The piston velocity is slower than the calibration velocity measured, by the percentage amount selected by the user (20%, 40% or 60%). If the user selects 0%, this monitoring or alarm feature is disabled.

If generated, shot size accuracy may be degraded. Typically the problem is created when the machine pressure regulator is adjusted to different value from when the machine was calibrated. Another less likely cause could be a mechanical failure with dispensing (worn piston, etc.). This error will not be generated for a purge shot or when the machine is in Operator mode.

Delta Velocity (“V”) Plus Error

E26 The piston velocity is faster than the calibration velocity measured, by the percentage amount selected by the user (20%, 40% or 60%). If the user selects 0%, this monitoring or alarm feature is disabled.

If generated, shot size accuracy may be degraded. Typically the problem is created when the machine pressure regulator is adjusted to different value from when the machine was calibrated. Another less likely cause could be a mechanical failure with dispensing (worn piston, etc.). This error will not be generated for a purge shot, or when the machine is in Operator mode.

Low Material Level, Tank A Alarm or Error

E27 Tank A is low (only generated if tank sensing is enabled). Fill tank A with material.

Tank level errors will be generated after every shot if the condition still exists.

Low Material Level, Tank B Alarm or Error

E28 Tank B is low (only generated if tank sensing is enabled). Fill tank B with material.

Tank level errors will be generated after every shot if the condition still exists.

Error Code Table · Communication Error · Improper Calibration Error

Page 25 of the Graco PR70 user manual — Error Code Table
Page 25 · click to enlarge
Page 25

Low Material Level, Both Tanks Alarm or Error

E29 Both tanks are low (only generated if tank sensing is enabled). Fill both tanks with material.

Tank level errors will be generated after every shot if the condition still exists.

Bad Linear Position Sensor

E50 There is a fault with the linear position sensor. Check wiring or replace.

Table 1Error Code Table

Error Code Table

Page 26 of the Graco PR70 user manual — Error Code Table
Page 26 · click to enlarge
Page 26
Graco PR70 — Error Code Table diagram (page 26)
Fig. 36 · Error Code Table

Red Stop or Cancel (Stops Operation Immediately, regardless of Screen). All

Up (Used to Raise Numerical Entry, Screen Navigation or Shot Selection). Many

Down (Used to Lower Numerical Entry, Screen Navigation or Shot Selection). Many

Table 2PR70 HMI ICON Table
Graco PR70 — Error Code Table diagram (page 26)
Fig. 37 · Error Code Table
Tables 3PR70 Screen ICON Tables

ICON Tables

Page 27 of the Graco PR70 user manual — Error Code Table
Page 27 · click to enlarge
Page 27
Graco PR70 — Error Code Table diagram (page 27)
Fig. 38 · Error Code Table
Tables 4PR70 Screen ICON Tables (Continued)

ICON Tables

Page 28 of the Graco PR70 user manual — Run Token
Page 28 · click to enlarge
Page 28

Maintenance, Software Upgrades and Run Token

4. Insert a black programming token into the slot provided. Make sure it snaps into place when inserted.

Maintenance

The following items should be checked daily, once during a shift, or as required for the application:

5. Turn ON the AC power switch.
  • Air Filter - Check air filter and release any water circuit water trapped in the base of the filter.
6. Verify the red LED on the FCM or HMI starts blinking at a fast steady rate, then the red LED stops flashing accordingly. Verify the Green LED is on continuously, and the amber LED blinks every few seconds.
  • Tanks – Check material levels and refill as necessary. Verify the material reservoirs are vented properly.
7. Turn OFF the AC power switch.
  • Air Dryer - Check the condition of the desiccant air dryer, and replace if necessary.
8. Remove the programming token from the FCM or HMI. If the second electronic component needs updating, insert the token into the other electronic module. If the FCM was re-programmed, re-insert the blue run token in the slot provided.
  • Pump Shafts – Clean both pump shafts with solvent and lubricate with approved lubricant such as mesamoll or Silicon oil.
  • Dispense Head – Dismantle, clean thoroughly and re-assemble. Lubricate all parts with a thin coat of approved lubricant, or silicon oil.
9. If programming a second electronic module, repeat steps 5 through 8.
10. Re-apply machine power.
  • Ratio Check – If material ratio is critical for the application, implement the ratio check procedure as required.
11. Go to the M4 screen to verify the new software revision(s).

Run Token

Software Upgrades, Run Token

The PR70 Fluid control module (FCM) contains a blue run token, installed in the socket provided. It has identical appearance to the black programming token, but is blue.

When software in the HMI or Fluid Control Module (FCM) needs updating, a black Graco update token is used.

Graco PR70 — Run Token diagram (page 28)
Fig. 39 · Run Token

If the token is not installed into the FCM, the machine will not operate, and an E13 error will be generated on the display module. Hence, if the FCM software is updated, it will need to be re-installed at the end of the re-programming procedure.

Graco PR70 — Run Token diagram (page 28)
Fig. 40 · Run Token
Graco PR70 — Run Token diagram (page 28)
Fig. 41 · Run Token
Figure 36Standard Graco Data Token

To transfer an updated software program from the token to the PR70 HMI or FCM:

1. Turn OFF the AC power switch in the back of the machine.
2. If updating the Fluid Control Module (FCM), open the access door to the FCM by loosening the 2 access screws. Remove the Blue Run token from the FCM.
3. If updating the Human Machine Interface (HMI), remove the HMI from the mounting bracket and remove the back cover by removing the 4 screws on the back of the enclosure.
Page 29 of the Graco PR70 user manual — PROBLEM CAUSE SOLUTION
Page 29 · click to enlarge
Page 29

Troubleshooting

3. Allow the machine to cool, if the machine has a heat control option.

Try the recommended solutions in the order given for the each problem to avoid unnecessary repairs. Also verify all circuit breakers, switches, and controls are properly set and wiring is correct before assuming there is a problem.

Before starting any troubleshooting procedures:

1. Relieve pressure (refer to Pressure Relief Procedure Section).
2. Disconnect AC power to the machine.

PROBLEM CAUSE SOLUTION

No Power Verify rear AC Power switch is ON. Fuse Blown Replace Machine fuses (Refer to “Miscellaneous Mechanical Assemblies” Section). Loose connection Tighten 5 pin cable on HMI. Bad HMI Replace HMI

HMI Display Completely Dark

Ball Valve Closed Open Tank Ball Valve (if installed). Tank empty Fill tank with material Tank Clogged Verify no obstruction in the tank Air in material Prime the machine until the air is removed. Check valve malfunction Remove, clean or replace check valve. Piston worn or broken Remove and replace piston if worn.

No or incorrect amount of material dispensed from either side

Re-connect input air line to machine. Increase air pressure regulator adjustment. Mixer blocked Replace static mixer. Incorporate or decrease purge time amount to prevent mixer blockage. ODV adjustment too late Re-adjust the ODV setting to occur sooner (C3 screen section). Blocked Check valve Remove check valve, clean and replace. Air Cylinder Failure Remove air cylinder and re-install cylinder kit items if necessary. Significant material leaking from pump rear seal

Input Air Reduced or removed

Piston stalled (E21 Error)

Pump Shaft worn Remove pump shaft assembly, and re-install rear pump re-built kit.

Specific gravity of 1 or more of the 2 materials has changed since calibration.

Mix materials in tanks, dispense another shot, then re-weigh. Re-calibrate if necessary (C4 section). Machine Air pressure has changed since calibration.

Re-adjust air pressure regulator to value used when machine was calibrated, or re-calibrate (C4

Material dispensed not correct weight

% level. Not enough material in 1 or more tanks

section). Turn ON or decrease

Check tank levels, and fill and prime if necessary. Mixer has slight obstruction Replace static mixer. Re-prime machine. Check valve malfunction Remove check valve(s), clean or replace if necessary. Piston worn or broken Remove and replace piston(s) if necessary.

One tank is empty Check tank levels. Add material if necessary. Tank Ball valve Closed Open tank ball valve. Re-prime machine. Machine out of phase Re-phase machine (C2 section). Check valve malfunction Remove check valve(s), clean or replace if necessary. Piston worn or broken Remove and replace piston(s) if necessary. Pumps drawing material back from valve hose

Machine dispensing off ratio

Check valve stuck open Remove check valve(s), clean or replace if necessary.

Troubleshooting

Page 30 of the Graco PR70 user manual — Major Mechanical Assemblies, and Attachments
Page 30 · click to enlarge
Page 30

Base Frame and Air Cylinder Assemblies

Repair

Major Mechanical Assemblies, and Attachments

Graco PR70 — Major Mechanical Assemblies, and Attachments diagram (page 30)
Fig. 42 · Major Mechanical Assemblies, and Attachments
Figure 38PR70 Top View w/o Tanks with Footswitch and HMI Illustrated
Figure 39PR70 Base Frame to Air Cylinder, Pump and Drive Block Attachments

Key:

Ref P/N Description QTY Ref P/N Description QTY 1 LC0112 Pump Assembly, PR70 1 5 LC0107 Drive Block Assembly, PR70 1 2 120913 Screw, SHC, M8-1.25 x 25 4 6 121166 Screw, SHC, M6-1.0 x 40 4 3 120919 Nut, Hex, M14 7 LC0109 Base Frame Assembly 1 4 LC0110, or LC0111

Air Cylinder Assemblies, 3.0” or 4.5” 1 8 121167 Screw, SHC, M8 - 1.25 x 40 4

Page 31 of the Graco PR70 user manual — Base Frame Assembly
Page 31 · click to enlarge
Page 31

Base Frame and Air Cylinder Assemblies

Figure 40PR70 Power Entry Bracket and Control Bracket Assembly Attachments

Key:

Ref P/N Description QTY Ref P/N Description QTY 1 120885 Screw, SHC, M5 – 0.8 x 14 4 3 LC0106 Power Entry Assembly, PR70 1 2 LC0108 Control Bracket Assembly, PR70 1 4 120885 Screw, SHC, M5 – 0.8 x 14 2

Base Frame Assembly

Figure 41PR70 Base Frame Assembly (LC0109)

Key:

Ref P/N Description QTY Ref P/N Description QTY 1 120599 PIN, DOWEL, 3/8DIAX1.50LG, SS 2 5 15K796 CLAMP 1 2 120885 SCREW,SHC, M5-0.8X14,MS,E 2 6 LC0033 TRANSDUCER ASSY, LINEAR, PR70S 1 3 120913 SCREW,SHC, M8X1.25X25,MS, E 2 7 120918 GUIDE, LINEAR 1 4 15K788 FRAME, BASE, PR70S, MACHINED 1 8 120886 SCREW, SHC,M6-1.0X25,MS,E 4

Page 32 of the Graco PR70 user manual — Air Cylinder Assemblies, and Rebuild Kits
Page 32 · click to enlarge
Page 32

Base Frame and Air Cylinder Assemblies

Air Cylinder Assemblies, and Rebuild Kits

Figure 42PR70 Air Cylinder System and Schematic
Page 33 of the Graco PR70 user manual — Air Cylinder Assemblies, and Rebuild Kits
Page 33 · click to enlarge
Page 33
Graco PR70 — Air Cylinder Assemblies, and Rebuild Kits diagram (page 33)
Fig. 43 · Air Cylinder Assemblies, and Rebuild Kits
Figure 43PR70 Air Cylinder Assemblies, 3.0” & 4.5” Diameters (LC0110 & LC0111)

Key:

(LC0110, 3.0” DIA. Assy., PR70) (LC0111, 4.5” DIA. Assy., PR70)

Ref P/N Description QTY Ref P/N Description QTY 1 107571 ORING, VIT, BAD 1 1 107571 ORING,VIT,BAD 1 2 114100 SCREW, SHC, M4X0.7X55, MS, E 3 2 114100 SCREW, SHC, M4X0. 7X55,MS,E 3 3 120875 ORING, VIT, CCE 1 3 104131 ORING,VIT,CDG 1 4 120880 SCREW, SHC, M8-1.25 X 125, MS, E 4 4 120880 SCREW,SHC,M8-1.25X125,MS,E 4 5 120881 BEARING, 1.00ID X 1.252 OD X 1.00LG, 1 5 120881 BEARING, 1.00IDX1.252ODX 1.00LG 1 6 120884 SCREW, SHC, M12-1.75 X 20, MS 1 6 120884 SCREW, SHC,M12-1.75X20,MS 1 7 120899 VALVE, 4W, 3P, COE, DSSC, ¼ NPT, 24VDC 1 7 120899 VALVE, 4W, 3P,COE, DSSC, 1/4NPT, 24VDC 1 8 120900 VALVE, PWR, 4W, SSSR, 1/4NPT, 24VDC 1 8 120900 VALVE,PWR,4W, SSSR, ¼ NPT, 24VDC 1 9 120922 MUFFLER, AIR, ¼ NPT, FLOW CONTROL 1 9 120922 MUFFLER,AIR, 1/4NPT, FLOW CONTROL 1 10 120923 ELBOW, SWVL, ¼ TUBE X 10-32, FXM, 90o, 1 10 120923 ELBOW, SWVL, ¼ X 10-32, FXM, 90o, CM/PL 1 11 120932 ORING, VIT, JDA 2 11 104271 ORING,VIT,JDG 2 12 121018 ELBOW, SWVL, 3/8 TUBE X ¼ NPT, FXM, 90o 5 12 121018 ELBOW,SWVL,3/8TUBEX ¼ NPT, FXM, 90DE 5 13 121020 ELBOW, SWVL, EXT'D, ¼ X ¼ NPT, FXM, 90o 1 13 121020 ELBOW, SWVL, EXT'D, ¼ X ¼ NPT, FXM, 90o 1 14 121021 MUFFLER, AIR, ¼ NPT, BRONZE 3 14 121021 MUFFLER,AIR, ¼ NPT, BRONZE 3 15 121022 ELBOW, SWVL, ¼ TUBE X ¼ NPT, FXM, 90o 2 15 121022 ELBOW, SWVL, ¼ TUBE X ¼ NPT, FXM, 90DE 2 16 15K790 TUBE, AIR CYL, 3.0 I.D., PR70S 1 16 15K789 TUBE, AIR CYL,4.5 I.D.,PR70S 1 17 15K791 BLOCK, AIR CYL, ROD END, PR70S 1 17 15K791 BLOCK, AIR CYL, ROD END, PR70S 1 18 15K792 BLOCK, AIR CYL, BLIND END, PR70S 1 18 15K792 BLOCK, AIR CYL, BLIND END, PR70S 1 19 15K793 PISTON,AIR CYL, 3.0 I.D., PR70S 1 19 15K794 PISTON, AIR CYL,4.5 I.D.,PR70S 1 20 15K795 ROD, PISTON, AIR CYL, PR70S 1 20 15K795 ROD, PISTON, AIR CYL,PR70S 1

Air Cylinder Assemblies

Page 34 of the Graco PR70 user manual — NOTICE
Page 34 · click to enlarge
Page 34

To install a new Air Cylinder Kit:

12. Remove the cylinder rod from the rod end block, then remove the rod o-ring (item 3 of Figure 40) from the rod end block and replace.
1. Follow the Pressure Relief Procedure and turn off the machine.
13. Liberally apply Graco high temperature lubricant Grease (Graco P/N 115982) to the inside of the tube (16), the outside of the piston (19), all the o-rings and the cylinder rod (20).
2. Disconnect the airline, remove the PR70 Shroud, and remove the machine power entry assembly (item 3 or Figure 40) from the machine by removing the 2 attachment screws (4 of Figure 40).
14. Re-assemble the air cylinder. Attach the 2 drive blocks by reinstalling the 4 long screws (4) finger tight. Then
3. Remove the 2 air valves (items 7 & 8) from the cylinder end block (18) by removing the 3 attachment screws (2).

torque the screws as specified in note

of Figure 43 in a crisscross pattern.

4. Disconnect the air cylinder piston rod (20) from the machine drive block assembly (item 5 of Figure 39) by removing all hex nuts (item 3 of Figure 39) from the piston rod (additional nuts may be installed if the machine has a Hydracheck option). An open-end wrench will be required to prevent the rod from turning when the nuts are removed.

NOTICE

In the previous step, air cylinder damage may result if screws are not installed in a crisscross pattern.

15. Air Cylinder damage may result if bolts are not installed in a crisscross pattern.
5. Disconnect the air cylinder from the machine frame base assembly (item 7 of Figure 39) by removing the 4 screws (item 8 of figure 39), which attach the cylinder rod end block (17) to the frame. Access the screw through the 4 holes in the blind end block (18) using a long allen wrench.
16. Reinsert the air cylinder into the back of the machine by inserting the cylinder rod through the hole in the base frame and in the drive block.
17. Before the cylinder is completely in place, re-connect the airlines to the cylinder block elbows fittings (12). Verify the correct airlines are connected (see Figure 43).
6. Remove the air cylinder by pulling on the cylinder from the back of the machine.
18. Reattach the cylinder to the base frame by reinstalling the 4 screws (item 8 of Figure 39).
7. With the cylinder partially removed, disconnect the airlines at the air cylinder elbow fittings (12).
8. On a bench, disassemble the air cylinder by removing the 4 long screws (4), which connect the 2 cylinder blocks.
19. Reattach the cylinder to the drive block by reinstalling the hex nut (item 3 of Figure 39) to the cylinder rod. Torque

the nut as specified in note

of Figure 39.

9. Inspect the cylinder tube (16) and piston (19) to verify no scratches exists. Replace if necessary.
20. Reattach the valves to the blind end block by reattaching the 3 screws (2).
10. Using a clean dry cloth, remove any existing grease from the inside of the tube (16), the outside of the piston (19) and the cylinder rod (20).
21. Reattach the power entry assembly by reinstalling the 2 attachment screws (item 4 of Figure 40).
11. Remove the 2 cylinder block o-rings (item 2 of Figure 40) from the blocks and replace. Remove the piston o-ring and replace (item 1 of Figure 40).
22. Reconnect input air into the machine. Operate the machine accordingly , and verify no air leaks are found. Recalibrate the machine.
Graco PR70 — NOTICE diagram (page 34)
Fig. 44
Graco PR70 — NOTICE diagram (page 34)
Fig. 45

Figure 44: PR70 Air Cylinder Rebuild Kits, 4.5” and 3.0” Diameter Versions (LC0092 & LC0091).

Key:

(LC0092, 4.5” DIA. Rebuild Kit) (LC0091, 3.0” DIA. Rebuild Kit) Ref P/N Description QTY Ref P/N Description QTY 1 104131 ORING, VIT, CDG 1 1 120875 ORING, VIT, CCE 1 2 104271 ORING, VIT, JDG 2 2 120932 ORING, VIT, JDA 2 3 107571 ORING, VIT, BAD 1 3 107571 ORING, VIT, BAD 1

Pump Assembly

Page 35 of the Graco PR70 user manual — Pump Assemblies and Rebuild Kits
Page 35 · click to enlarge
Page 35

Drive Block Assembly

Graco PR70 — Drive Block Assembly diagram (page 35)
Fig. 46 · Drive Block Assembly
Figure 45PR70 Drive Block Assembly (LC0107)

Key:

Ref P/N Description QTY Ref P/N Description QTY 1 120891 SCREW, SHS, M6-1.0 X 8, MS 2 4 15K805 BLOCK, DRIVE, PR70S 1 2 15K801 ROD, ALIGNMENT 2 5 15K868 WASHER, SPERICAL, ½ DIA. MODIFIED 2 3 15K802 NUT, RETAINER 2 6 84/0130- 27/11 LABEL, HAND CRUSH, 1.3 X 1.1, TRIANGLE, ISO

Pump Assemblies and Rebuild Kits

Figure 46PR70 Pump Assembly (LC0112)

Pump Assembly

Page 36 of the Graco PR70 user manual — Drive Block Assembly
Page 36 · click to enlarge
Page 36

Key:

Ref P/N Description QTY Ref P/N Description QTY 1 106258 ORING, VIT, JCB 2 9 15K803 COLLAR, PUMP 2 2 108712 NUT, HEX, M8 X 1.25, MS 2 10 15K804 HOUSING, BEARING, SEAL, PR70S 2 3 120887 POSIPAK, 0.375ID X 0.625OD, COIL 2 11 15K824 SHAFT, PISTON, 3/8, PR70S, SS 2 4 120890 RING, RET, INT, 1.00, SS 2 12 15K828 WASHER, SEAL, 3/8, PR70S, SS 2 6 120982 SCREW, SHC, M8 X 1.25 X 65, MS, E 8 13 15K895 HOUSING, CHECK VALVE 2 7 15K786 HOUSING, PUMP, PR70S, MACHINED 1 14 LC0093 KIT, REBUILD, VALVE, CHECK, PR70S 2 8 15K787 CAP, END, PUMP, PR70S, MACHINED 2 To install a new Check Valve Rebuild Kit:

8. With the rounded inside surface of the check valve seat (item 4 of figure 47) facing down, place the seat on top of the check valve ball.
1. With the machine in an idle state and a bucket below the dispense valve to catch material, fully
9. Holding both ends of the assembled check valve assembly, install the check valve into the un-threaded end of the check housing (13) with the ball end facing out. Apply some pressure to the valve to snugly fit the completed check valve into the housing and the fit the check valve seat (item 4 of figure 47) into the valve guide.

extend the piston by pressing

in the M1 screen.

2. To prevent machine movement, press

(red).

3. With a bucket below the check valve to be replaced, disconnect the male hose fitting from the check valve housing (13), by loosing the hose from the housing. Catch any material draining from the hose into the bucket.
10. Verify when the assembled check valve and housing (13) are turned up-side down, that the contents of the valve stays in place.
4. Remove the check valve housing (13) from the pump endcap (8) by loosening the housing with a wrench.
11. Re-insert the new valve and valve housing into the pump end cap, using a wrench.
12. Re-install the material male hose fitting into the check valve housing using a wrench.
5. Remove the existing check valve (14) from the housing (13) by inserting a screwdriver or dowel rod into the female threaded end of the check valve housing.
13. Before re-using the machine for operation, activate a few shots to purge any air present in the material hose lines due to the procedure.
6. With the new check valve ball guide (item #3 in figure 43) on a bench with the open end up, install the check valve spring (item 2 of figure 47) into the guide.
14. Re-calibrate the machine if necessary.
7. Install the check valve ball (item 1 of figure 47) on top of the spring.
Graco PR70 — Drive Block Assembly diagram (page 36)
Fig. 47 · Drive Block Assembly
Figure 47PR70 Check Valve Rebuild Kit (LC0093)

Key:

Ref P/N Description QTY Ref P/N Description QTY 1 105445 BALL,CHECK VALVE 1 3 15D312 BUSHING, BALL GUIDE 1 2 121084 SPRING, 0.30OD X 0.44LG, 22#/IN, 20PSI, S 1 4 196832 SEAT, LAPPED, CHECK VALVE 1

Pump Assembly

Page 37 of the Graco PR70 user manual — Drive Block Assembly
Page 37 · click to enlarge
Page 37
Graco PR70 — Drive Block Assembly diagram (page 37)
Fig. 48 · Drive Block Assembly
Figure 48PR70 Rear Pump Rebuild Kit (LC0094)

Key:

Ref P/N Description QTY Ref P/N Description QTY 1 106258 ORING, VIT, JCB 1 3 120887 POSIPAK, 0.375ID X 0.625OD, COIL 1 2 120890 RING, RET, INT, 1.00, SS 1

To install a new Rear Pump Rebuild Kit:

10. Apply 1 layer of thin masking tape over the male threads of the pump shaft, which mates with the drive block. This will prevent the threads from damaging the seal or Posipak (3).
1. Drain the pump by taking several shots with either the tank ball valves closed (if installed), or by activating enough shots to empty the tanks.
11. Using extreme caution, slide the pump shaft through the hole in the bearing housing as indicated in Figure 48. Align the bearing housing in position next to the pump housing.
2. Disconnect the pump shaft (item 11 of Figure 46) from the drive block assembly by loosening the shaft locking nut (item 2 of Figure 46), then turning the shaft with a wrench while preventing the drive block alignment rod (item 2 of Figure 45) from rotating with a wrench. Manually push the pump shaft forward toward the extend position to separate the shaft from the drive block.
12. Re-install the pump collar over the bearing housing and attach it to the pump housing using the 2 screws (item 5 on Figure 46) previously removed.

Torque the screws as specified in note

of Figure 46.

3. Remove the shaft lock nut from the shaft.
4. Remove the pump collar (item 9 on Figure 46) from the pump housing (item 7 on Figure 46) by removing the 2 screws (item 5 on Figure 46).
13. Remove the masking tape from pump shaft.
14. Re-install the pump shaft lock nut to the pump shaft.
15. Re-install the pump shaft to the drive block alignment rod.
5. Slide the pump bearing housing (item 10 of Figure 46) away from the pump housing to remove.
6. Remove the existing rear pump build components (refer to Figure 48 items) from the pump bearing housing.
16. Re-tighten the lock nut.
17. Open the tank ball valves (if installed) and put more material into the tanks.
7. Using a clean dry cloth, remove any existing grease from the bearing housing.
18. Instigate several shot to fill the pump with new material.
8. Apply new high temperature grease lubricant (Graco P/N 115982) to the inside of the pump bearing housing, and the new rebuild components.
19. Re-calibrate and re-phase the machine, due to the procedure performed.
9. Install the new rebuild kit components into the bearing housing as indicated in Figure 48.

Pump Assembly

Page 38 of the Graco PR70 user manual — LCE - 160
Page 38 · click to enlarge
Page 38

Pistons & Metering Tubes

Piston Cylinders or Metering Tubes

Figure 49 PR70 Nylon and UHMWPE Piston Replacement Kits

Key:

Ref Description QTY Ref Description QTY 1 Piston 1 3 Oring 2 2 Screw 1

When ordering a piston replacement kit, the following intelligent part numbering system applies for Nylon based pistons:

The items indicated in Figure 49 above will be supplied with the kit. Refer to the Models section for the available standard piston sizes.

LCF - 120

CodeA

Piston Size (mm2)

When ordering a UHMWPE replacement kit, the following numbering applies:

LCE - 160

CodeA

Piston Size (mm2)

Page 39 of the Graco PR70 user manual — NYLON PISTONS (SEE FIGURE 50)
Page 39 · click to enlarge
Page 39

Pistons & Metering Tubes

To install a new Piston or Piston/Cylinder Replacement Kit:

installed), or by activating enough shots to empty the tanks.

1. Drain the machine pistons by instigating several shots with either the tank ball valves closed (if
2. To prevent machine movement, press

(red).

3. Remove the pump end caps (item 8 of figure 46) by removing the 4 end cap screws (item 6 of figure 46). Allow the cap to hang by the hose.
9. Select an operating mode, then retract the

in the M1 screen.

10. To prevent machine movement, press

(red).

4. Remove the cylinder and Orings (items 1 and 6 of figure 50) from the pump housing (item 7 of figure 46) and pump cap.
11. Lubricate the new o-rings with a high temperature grease, Graco P/N 115982 or equivalent. Place the lubricated o-rings into the inside circle placements in the pump housing and pump end caps.
5. Select an operating mode, then fully extend the

pistons by activating the

option in the M1 screen.

12. Install the cylinder between the pump housing and end cap, then secure the cylinder and Orings by re-attaching the 4 end cap screws (item 6 of figure 46).
6. To prevent machine movement, press

(red).

7. Remove the existing piston (1) and any front or rear washers (items 3 & 4 of figure 50) from the pump shaft (item 11 of figure 46) by removing the piston screw (2). A wrench will be required near the drive block to prevent the pump shaft from rotating while the screw is removed.
13. Open the tank ball valves (if installed) or put more material into the tanks.
14. Instigate several shot to fill the pump with new material.
8. Install the new piston and any rear or front washers, by re-installing the piston screw into the pump shaft. When tightening the piston screw, tighten the screw until the piston stops rotating, then turn the screw an additional ¼ turn.
15. Re-calibrate the machine, due to the procedure performed.

NYLON PISTONS (SEE FIGURE 50)

Tube Piston Frt. Washer

Back Washer Screw O-ring

Part No. Rev. Series Area Item 1 Item 2 Item 3 Item 4 Item 5 Item 6 LC1080 A A 80 LCC080 LCB080 15M089 NOT REQ

LC1100 A A 100 LCC100 LCB 100 15M089 NOT REQ LC1120 A A 120 LCC120 LCB 120 NOT REQ NOT REQ LC1140 A A 140 LCC 140 LCB 140 NOT REQ NOT REQ LC1160 A A 160 LCC 160 LCB 160 15M099 15K887 LC1180 A A 180 LCC 180 LCB 180 15M099 15K887 LC1200 A A 200 LCC 200 LCB 200 15M099 15K887 LC1220 A A 220 LCC 220 LCB 220 15M099 15K887 LC1240 A A 240 LCC 240 LCB 240 15M100 15K887 LC1260 A A 260 LCC 260 LCB 260 15M100 15K887 LC1280 A A 280 LCC 280 LCB 280 15M100 15K887 LC1300 A A 300 LCC 300 LCB 300 15M100 15K887 LC1320 A A 320 LCC 320 LCB 320 15M100 15K888 LC1360 A A 360 LCC 360 LCB 360 15M100 15K888 LC1400 A A 400 LCC 400 LCB 400 15M100 15K888 LC1440 A A 440 LCC 440 LCB 440 15M100 15K888 LC1480 A A 480 LCC 480 LCB 480 15M100 15K888 LC1520 A A 520 LCC 520 LCB 520 15M100 15K888 LC1560 A A 560 LCC 560 LCB 560 15M101 15K888 LC1600 A A 600 LCC 600 LCB 600 15M101 15K888 LC1640 A A 640 LCC 640 LCB 640 15M101 15K890 LC1720 A A 720 LCC 720 LCB 720 15M101 15K890 LC1800 A A 800 LCC 800 LCB 800 15M101 15K890 LC1880 A A 880 LCC 880 LCB 880 15M101 15K890 LC1960 A A 960 LCC 960 LCB 960 15M101 15K890

pistons by pressing · 120933 120874

Page 40 of the Graco PR70 user manual — NYLON PISTONS (SEE FIGURE 50)
Page 40 · click to enlarge
Page 40

Pistons & Metering Tubes

NYLON PISTONS (SEE FIGURE 50)

Tube Piston Frt. Washer

Back Washer Screw O-ring

Part No. Rev. Series Area Item 1 Item 2 Item 3 Item 4 Item 5 Item 6 LC2160 A A 160 LCA160 LCB160 15M099 15K887

LC2180 A A 180 LCA180 LCB 180 15M099 15K887 LC2200 A A 200 LCA200 LCB 200 15M099 15K887 LC2220 A A 220 LCA220 LCB 220 15M099 15K887 LC2240 A A 240 LCA240 LCB 240 15M100 15K887 LC2260 A A 260 LCA260 LCB 260 15M100 15K887 LC2280 A A 280 LCA280 LCB 280 15M100 15K887 LC2300 A A 300 LCA300 LCB 300 15M100 15K887 LC2320 A A 320 LCA320 LCB 320 15M100 15K888 LC2360 A A 360 LCA360 LCB360 15M100 15K888 LC2400 A A 400 LCA400 LCB400 15M100 15K888 LC2440 A A 440 LCA440 LCB440 15M100 15K888 LC2480 A A 480 LCA480 LCB480 15M100 15K888 LC2520 A A 520 LCA520 LCB520 15M100 15K888 LC2560 A A 560 LCA560 LCB560 15M101 15K888 LC2600 A A 600 LCA600 LCB600 15M101 15K888 LC2640 A A 640 LCA640 LCB640 15M101 15K890 LC2720 A A 720 LCA720 LCB720 15M101 15K890 LC2800 A A 800 LCA800 LCB800 15M101 15K890 LC2880 A A 880 LCA880 LCB880 15M101 15K890 LC2960 A A 960 LCA960 LCB960 15M101 15K890

Graco PR70 — NYLON PISTONS (SEE FIGURE 50) diagram (page 40)
Fig. 49
Graco PR70 — NYLON PISTONS (SEE FIGURE 50) diagram (page 40)
Fig. 50

Front and Rear Washer Reference Guide Tube Area Frt. Washer Back Washer 080 to 119 15M089 NOT REQ 120 to 159 NOT REQ NOT REQ 160 to 239 15M099 15K887 240 to 319 15M100 15K887 320 to 559 15M100 15K888 560 to 639 15M101 15K888 640 to 960 15M101 15K890

Figure 50Available PR70 Piston and Cylinder (Metering Tubes) Kits

Key:

Ref Description QTY Ref Description QTY 1 Cylinder or Metering Tube 1 4 Back Washer See Fig. 2 Piston 1 5 Screw 1 3 Front Washer See Fig.

120933 120874 · 6 Oring 2

Page 41 of the Graco PR70 user manual — Hose Assemblies
Page 41 · click to enlarge
Page 41
Graco PR70 — Hose Assemblies diagram (page 41)
Fig. 51 · Hose Assemblies
2. To prevent machine movement, press

(red).

3. Remove the existing Piston plug (1) from the pump end cap (item 8 of figure 46) with a wrench. Remove the existing Oring (2).
4. Lubricate the new Oring with a high temperature grease, Graco P/N 115982 or equivalent. Place the lubricated Oring into the cap location of the end cap.

Figure 51 PR70 Piston Plug Assembly

Key:

5. Re-install the piston plug (1) back into the end cap.

Ref P/N Description QTY 1 15K815 Plug 2/Machine 2 111457 Oring 2/Machine To install a new Piston Plug Assembly:

6. Open the tank ball valves (if installed) or put more material into the tanks.
7. Instigate several shot to fill the pump with new material.
1. Drain the machine pistons by instigating several shots with either the tank ball valves closed (if installed), or by activating enough shots to empty the tanks.
8. Re-calibrate the machine, due to the procedure performed.

Hose Assemblies

Graco PR70 — Hose Assemblies diagram (page 41)
Fig. 52 · Hose Assemblies

Figure 52 Piston to DV Hose Assemblies

Pistons

Page 42 of the Graco PR70 user manual — Hose Assemblies
Page 42 · click to enlarge
Page 42
Graco PR70 — Hose Assemblies diagram (page 42)
Fig. 53 · Hose Assemblies

Figure 53 Heated Piston to DV Hose Assemblies

Hose Assemblies

Page 43 of the Graco PR70 user manual — Miscellaneous Mechanical Assemblies
Page 43 · click to enlarge
Page 43

Miscellaneous Mechanical Assemblies

Figure 54PR70 Power Entry Bracket Assembly (LC0106)

Key:

Ref P/N Description QTY Ref P/N Description QTY 1 119912 SCREW, PAN, M3X6, PHILLIPS, SS 3 11 84/0130-26/11 LABEL, PE 1 2 121018 ELBOW, SWVL, 3/8 X ¼ NPT, FXM, 90DE 1 12 LC0034 HARNESS, WIRE, REMOTE SIGNAL 1 3 120876 PWR SUPPLY, 24VDC, 40W, 100-240VAC IN 1 13 121178 VALVE, LOCKOUT, ¼ NPT 1 4 120882 FILTER, 1/4NPT 1 14 121179 QUIKCLAMP, ¼ NPT 2 5 120883 NUT, HEX, 7/8-14, MS 1 15 121180 MULTIPORT, [3] ¼ NPT 1 6 120910 PWR ENTRY, 120/240VAC, DUAL FUSE, EMI 1 16 94/0762/99 VALVE, RELIEF, ¼ NPT, M, 110PSI, SIL 1 7 120916 SCREW,FHSC, M3X0.5 X 10, SS 2 17 94/0430/99 PLUG, SKT HD, ¼ NPT, MS 2 8 120993 NUT, HEX, M5X0.8, WITH STAR WASHER 2 18 81/1054-4/11 FUSE 5X20MM, 4AMP, FAST, TYPE F, 250VAC 2 9 15K798 BRACKET, SWITCH, AIR 1 19 LC0031 CABLE ASSY, POWER IN 1 10 15K800 FITTING, BULKHEAD 1 To Replace the Fuses:

2. Replace the blown fuse(s) (18) into the fuse holder.
1. Remove the machine fuse holder from the PWR Entry module (6) by inserting a flat-head screwdriver between the holder and the back the PWR Entry module (The fuse holder is above where AC power is connected to the machine).
3. Re-install the holder into the PWR Entry Module.

Miscellaneous Assemblies

Page 44 of the Graco PR70 user manual — Miscellaneous Mechanical Assemblies
Page 44 · click to enlarge
Page 44
Figure 55PR70 Control Bracket Assembly (LC0108)

Key: Ref P/N Description QTY Ref P/N Description QTY 1 84/0153-1/89 CLAMP, HARNESS, REUSEABLE, 5/8,NYL 2 6 121019 ELBOW, SWVL, 3/8 X 3/8 NPT, FXM, 90DE 1 2 120885 SCREW, SHC, M5-0.8 X 14, MS, E 2 7 LC0124 CONTROLLER, FCM 1 3 120897 REGULATOR, 100PSI, 3/8NPT, GAGE 1 8 15K797 BRACKET, ELECTRICAL, 1 4 120954 MANIFOLD, PN, 3/8NPTX3/8T X ¼ TX1/4T 1 9 84/0130-25/11 LABEL,.375X.375 1 5 120993 NUT, HEX, M5X0.8, WITH STAR WASHER 5 10 LC0035 HARNESS, WIRE, I/O 1

Graco PR70 — Miscellaneous Mechanical Assemblies diagram (page 44)
Fig. 54 · Miscellaneous Mechanical Assemblies
Figure 56PR70 Shroud Assembly (LC0113)

Key:

Ref P/N Description QTY 1 15V962 SHIELD, PR70, FIXED RATIO, GCA 1 2 15M511 LABEL, WARNING 4 3 16P016 PR70, FIXED RATIO 1

Miscellaneous Assemblies

Page 45 of the Graco PR70 user manual — Miscellaneous Mechanical Assemblies
Page 45 · click to enlarge
Page 45
Figure 57PR70 Hydracheck Components
Figure 58PR70 HMI Components

Key:

Ref P/N Description QTY Ref P/N Description QTY 1 288446 Display Module, PR70 1 3 120999 Termination Plug 1 2 255235 Bracket, HMI 1

Miscellaneous Assemblies

Page 46 of the Graco PR70 user manual — Wiring Diagrams
Page 46 · click to enlarge
Page 46
Figure 59PR70 Wiring Interconnect Illustration

Wiring Diagrams

Wiring Diagrams

Page 47 of the Graco PR70 user manual — Wiring Diagrams
Page 47 · click to enlarge
Page 47
Graco PR70 — Wiring Diagrams diagram (page 47)
Fig. 55 · Wiring Diagrams
Figure 60Wiring Diagram, PR70

(121685) · Wiring Diagrams

Page 48 of the Graco PR70 user manual — Technical Data
Page 48 · click to enlarge
Page 48

Technical Data

Metering Pump Effective Area 80 – 960 mm2 (0.124 – 1.49 in2) per side

Small Air Cylinder Effective Area 4560 mm2 (7.07 in2)

Large Air Cylinder Effective Area 10260 mm2 (15.9 in2)

Maximum Stroke Length 38.1 mm (1.50 in)

Minimum Stroke Length 5.8 mm (0.23 in)

Volume per Cycle 2 – 70 cc (0.12 – 4.3 in3)

Pump Cycles per 1L (0.26 gal) 500 – 14.3

Ratios (fixed) 1:1 to 12:1 (depending upon cylinders selected)

Maximum Fluid Working Pressure 3000 psi (20.7 MPa, 207 bar)

Maximum Air Input Pressure 100 psi (0.7 MPa, 7 bar)

Maximum Cycle Rate 30 cpm

Maximum Operating Temperature 70 C (160 F), nylon pistons 50 C (120 F) UHMWPE pistons or PE Tanks

Air Inlet Size ¼ NPT (f)

Pump Fluid Outlet Size -03, -04, -06, -08 or –12 JIC fittings for 3/16 in (4.8 mm), ¼ in (6.4 mm), 3/8 in

(9.5 mm), ½ in (12.7 mm), ¾ in (19.1 mm) hoses

Wetted Parts 303/304, 17-4 PH, hard chrome, Chromex, carbide, Chemical Resistant O-rings, PTFE, nylon, UHMWPE

Weight 55 kg (120 Lbs) typical with two 7.5L tanks 150 kg (330 Lbs) typical with two 60 L tanks

Sound Power Level 4 in Air Cylinder Measured Per ISO Standard 9614-2

100 psi/30 cpm - 81 dBA

50 psi/15cpm – 77 dBA

Compressed Air < 10 scfm typical (varies with cycle times)

Electrical Power 100-240 V 50/60Hz, 1 phase for machine – 80 Watts 208-240V 50/60Hz, 1 phase for heat – 11 kW max. 120 or 240 VAC 50/60Hz 1 phase for on-board agitators, 80 Watts 240 VAC 50/60Hz 1 phase for off-board agitators, 830 Watts

Technical Data · Category Data

Page 49 of the Graco PR70 user manual — Dimensions
Page 49 · click to enlarge
Page 49

Dimensions

Graco PR70 — Dimensions diagram (page 49)
Fig. 56 · Dimensions

Figure 36: PR70 Dimensions (ON-Board PE Tank version Illustrated) A typical PR70 Machine, with the standard On-Board twin 8 liter PE Tanks has the following dimensions: Dimension In. (mm) Dimension In. (mm) A (width) 18.49 (469.6) C (depth) 30.62 (777.7) B (height) 26.39 (670.3) D (height in Back) 13.39 (340.1)

A typical PR70 Machine, with the standard On-Board 7.5 liter Stainless Steel Tanks has the following dimensions: Dimension In. (mm) Dimension In. (mm) A (width) 15.5 (393.7) C (depth) 30.62 (777.7) B (height) 27.37 (695.2) D (height in Back) 13.39 (340.1)

Technical Data

Page 50 of the Graco PR70 user manual — Graco Information
Page 50 · click to enlarge
Page 50

Warranty and Graco Contact Information

Graco Ohio Standard Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non- Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information

For the latest information about Graco products, visit www.graco.com TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Toll Free: 1-800-746-1334 or Fax: 330-966-3006

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

For patent information, see www.graco.com/patents

Original instructions. This manual contains English. MM 312393

Graco HeadquartersMinneapolis International Offices: Belgium, China, Japan, Korea
  • GRACO INC. AND SUBSIDIARIES
  • P.O. BOX 1441
  • MINNEAPOLIS MN 55440-1441
  • USA

Copyright 2007, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.

www.graco.com

Revised November 2013

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Fix-it

Troubleshooting

Common problems, likely causes, and what to do.

ProblemPossible causeRemedy
HMI Display Completely DarkNo PowerVerify rear AC Power switch is ON. p.29
HMI Display Completely DarkFuse BlownReplace Machine fuses (Refer to “Miscellaneous Mechanical Assemblies” Section). p.29
HMI Display Completely DarkLoose connectionTighten 5 pin cable on HMI. p.29
HMI Display Completely DarkBad HMIReplace HMI p.29
No or incorrect amount of material dispensed from either sideBall Valve ClosedOpen Tank Ball Valve (if installed). p.29
No or incorrect amount of material dispensed from either sideTank emptyFill tank with material p.29
No or incorrect amount of material dispensed from either sideTank CloggedVerify no obstruction in the tank p.29
No or incorrect amount of material dispensed from either sideAir in materialPrime the machine until the air is removed. p.29
No or incorrect amount of material dispensed from either sideCheck valve malfunctionRemove, clean or replace check valve. p.29
No or incorrect amount of material dispensed from either sidePiston worn or brokenRemove and replace piston if worn. p.29
Piston stalled (E21 Error)Input Air Reduced or removedRe-connect input air line to machine. Increase air pressure regulator adjustment. p.29
Piston stalled (E21 Error)Mixer blockedReplace static mixer. Incorporate or decrease purge time amount to prevent mixer blockage. p.29
Piston stalled (E21 Error)ODV adjustment too lateRe-adjust the ODV setting to occur sooner (C3 screen section). p.29
Piston stalled (E21 Error)Blocked Check valveRemove check valve, clean and replace. p.29
Piston stalled (E21 Error)Air Cylinder FailureRemove air cylinder and re-install cylinder kit items if necessary. p.29
Significant material leaking from pump rear sealPump Shaft wornRemove pump shaft assembly, and re-install rear pump re-built kit. p.29
Material dispensed not correct weightSpecific gravity of 1 or more of the 2 materials has changed since calibration.Mix materials in tanks, dispense another shot, then re-weigh. Re-calibrate if necessary (C4 section). p.29
Material dispensed not correct weightMachine Air pressure has changed since calibration.Re-adjust air pressure regulator to value used when machine was calibrated, or re-calibrate (C4 section). Turn ON or decrease % level. p.29
Material dispensed not correct weightNot enough material in 1 or more tanksCheck tank levels, and fill and prime if necessary. p.29
Material dispensed not correct weightMixer has slight obstructionReplace static mixer. Re-prime machine. p.29
Material dispensed not correct weightCheck valve malfunctionRemove check valve(s), clean or replace if necessary. p.29
Material dispensed not correct weightPiston worn or brokenRemove and replace piston(s) if necessary. p.29
Machine dispensing off ratioOne tank is emptyCheck tank levels. Add material if necessary. p.29
Machine dispensing off ratioTank Ball valve ClosedOpen tank ball valve. Re-prime machine. p.29
Machine dispensing off ratioMachine out of phaseRe-phase machine (C2 section). p.29
Machine dispensing off ratioCheck valve malfunctionRemove check valve(s), clean or replace if necessary. p.29
Machine dispensing off ratioPiston worn or brokenRemove and replace piston(s) if necessary. p.29
Pumps drawing material back from valve hoseCheck valve stuck openRemove check valve(s), clean or replace if necessary. p.29

Ask about the Graco PR70

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco PR70

Be the first to ask — other owners or our team will answer.

Original document

Graco PR70 manual PDF

50 pages·2.2 MB·Water Dispenser·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…