PrecisionSwirl ™ Module
An orbital dispenser used to apply sealant and adhesive materials for a variety of applications.
3500 psi (24.1 MPa, 241 bar) Maximum Fluid Working Pressure

See page 2 for List of Models.
U.S. Patent No. 6,499,673 EU Patent No. 0852160

MAIN RUN / ENABLE
CONTROL SELECT
MANUAL SPEED CONTROL
AUTOMATIC MANUAL
PrecisionSwirl Orbital Dispenser 243402 and 243403
8037B PrecisionSwirl Control Assembly
918616 289261 and 289262
PrecisionSwirl Orbital Dispenser

Tool Mounted Dispensers
PrecisionSwirl Orbital Dispenser and Control Assembly Kit includes 233123, 243403, 617829, 617870 and 918616.
PrecisionSwirl Orbital Dispenser and Control Assembly Kit includes 233123, 243402, 617829, 617870 and 918616.
PrecisionSwirl Orbital Dispenser and Control Assembly Kit includes 233123, 289261, 617829, 617870 and 918616.
PrecisionSwirl Orbital Dispenser and Control Assembly Kit includes 233123, 289262, 617829, 617870 and 918616.
Cable Assemblies
Part No. 233125
6 ft (1.8 m) Motor Extension Cable Assembly
Part No. 233124
9 ft (2.7 m) Motor Extension Cable Assembly
15 ft (4.6 m) Motor Extension Cable Assembly
55 ft (16.8 m) Motor Extension Cable Assembly
40 ft (12.2 m) Robot Interface Cable Assembly
List of Models · Tool Mount · PrecisionSwirl Control Assembly


The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.




Unpacking the Product
The PrecisionSwirl orbital dispenser and control assem- bly were carefully packaged for shipment by Graco. When the package arrives, perform the following proce- dure to unpack the units:
When the PrecisionSwirl orbital dispenser requires ser- vice, it is the purchaser’s responsibility to have the unit repaired. As an option, the purchaser can have the unit repaired by an authorized Graco distributor. For addi- tional information, read the following subsections.
PrecisionSwirl components are customarily serviced by the purchaser or an authorized Graco technician. When service is required, follow the Service procedures in this manual.
The PrecisionSwirl orbital dispenser can be serviced by an authorized Graco distributor after completing a Return Goods Authorization (RGA) form. The purchaser must re–package and ship the orbital dispenser to the Graco distributor. When repacking the orbital dispenser, perform the following steps:
Unpacking and Repacking

PrecisionSwirl Capabilities
The PrecisionSwirl orbital dispenser is regulated through the control assembly. The orbital dispenser is used to swirl sealant and adhesives in a variety of appli- cations.
In a basic robotic system, the control assembly serves as the interface between the robot controller and the orbital dispenser via an interface cable. Refer to Robot Interface Cable Assembly on page 52.
The orbital dispenser is operated either manually from the control assembly or automatically from a robot con- troller where the orbital dispenser is programmed to apply material continuously, or at interrupted intervals, or both. The orbital dispenser can be stopped, started, and regulated to suit the application, making high quality swirl patterns that hold form after the material is dis- pensed.
The orbital dispenser applies a continuous swirled bead of material directly on components in targeted areas, such as the hem flanges on car doors, the interior seams of the chassis, and on the fixed glass openings of autos.
Bead profile is “pre–shaped” in a uniform pattern of overlaid circular loops (see FIG. 2). Bead shape is affected by nozzle size, material composition, flow rate, stand off distance, and orbital dispenser motor speed. The oscillating nozzle on the orbital dispenser can apply an accurate swirled bead of material on vertical and hor- izontal planes.
The orbital dispenser is small enough to apply sealant and adhesives on any type of surface or material, and can be directed on any programmable path, including: a series of crevices, creases, or around a maze of straight lines, sharp angles, contours, curves, corners, and openings.
The material source for the orbital dispenser is com- monly supplied via a dual ram pump fluid supply system, which can be equipped with filters, temperature condi- tioning, and a fluid supply header.
PrecisionSwirl Overview

4 Automatic control cable (PrecisionSwirl). Also called robot interface cable in this manual. 5 6, 9, or 15 ft (1.8, 2.7, or 4.6 m) flexible motor cable for robot mounting (PrecisionSwirl) 6 55 ft (16.8 m) motor cable (PrecisionSwirl) 7 Dispense valve (not included) 8 Sealer robot 9 Robot controller 10 Fluid supply system 11 Fluid supply header
FIG. 3 shows the PrecisionSwirl components in a basic robotic system. The following list identifies the Preci- sionSwirl components:
No. Description 1 Control assembly (PrecisionSwirl) 2 Orbital dispenser (PrecisionSwirl)

PrecisionSwirl Overview

Installing the Control Assembly
To install the control assembly:
Allow sufficient space for mounting and using the equip- ment:
ELECTROCUTION HAZARD Installing and servicing this equipment requires access to parts which could cause an electric shock or other serious injury. Have only qualified electricians access the control assembly.
Before installing the control assembly:
EQUIPMENT MISUSE HAZARD The PrecisionSwirl control assembly weighs approxi- mately 23.5 lb (10.7 kg). Exercise care when mounting and handling the control assembly to prevent equip- ment damage or personal injury.

Installing the Control Assembly


Grounding the Control Assembly
If power and grounding connections are not done properly, the equipment may be damaged and the warranty will be voided.
To help avoid damage to equipment, make sure that the robot and PrecisionSwirl equipment are grounded to the same point.
Connect a ground wire from the GND terminal in the PrecisionSwirl control assembly (shown in FIG. 5) to a true earth ground.
'.$
'.$
'.$
'.$
'.$
,,.0% 6!# 0( (:
'.$

Perform the following procedure to connect the control assembly to a power source.
To connect the control assembly to the electrical source:
ELECTRIC SHOCK HAZARD Do not connect the PrecisionSwirl control assembly to a power source unless you are a trained electrician. Failure to follow standard procedures or to observe the necessary precautions could result in serious bodily injury or equipment damage.
0/7%2 3500,9 !54/-!4)##/.42/,
If power and grounding connections are not done properly, the equipment may be damaged and the warranty will be voided.
7/8 in. Diameter power supply entry
Have a qualified electrician connect the PrecisionSwirl control assembly to a grounded electrical source that has the following required service ratings:
Any fitting that is used to connect a power cord (or conduit for power wiring) to the control assembly must provide a liquid–tight seal.
Full Load Amps 0.42 at 120 Vac
Circuit Breaker 5 Amp
Power to the control assembly must be supplied from a source with a lockable–off disconnect switch, or by use of a cord with a plug–and–socket connection to the source of power.

'.$
'.$
'.$
'.$
'.$
,,.0% 6!# 0( (:
'.$
Checking Resistance Between the Control Assembly and the True Earth Ground
FIRE, EXPLOSION, AND ELECTRIC SHOCK HAZARD To reduce the risk of fire, explosion, or electric shock, the resistance between the supply unit components and true earth ground must be less than 0.25 ohms.
Have a qualified electrician check the resistance between each system component and the true earth ground. The resistance must be less than 0.25 ohms. If the resistance is greater than 0.25 ohms, a different ground site may be required. Do not operate the Preci- sionSwirl module until the problem is corrected.

Installing the Dispense Valve
To install the dispense valve:
Attach the dispense valve to the mounting bracket on a stationary support or robotic arm, using two socket head screws (38) and flat washers (39).
The customer must provide a four–way pneumatic valve, activated by a separate on/off dispense sig- nal via the robot, to control material flow.
Securely connect air lines to dispense valve air ports (F). Make sure to connect the appropriate air lines to the appropriate ports.
Securely connect the material hose to dispense valve inlet port (A).
Refer to Dispense Valve manuals 308876 and 309376.

Always make connections to the control assembly with power turned off.
Motor control cables are supplied in four lengths, 6 ft (1.8 m), 9 ft (2.7 m), 15 ft (4.6 m), and 55 ft (16.8). The 55 ft cable may be used by itself. The 6 ft, 9 ft, and 15 ft cable must be used with the 55 ft cable.
To connect the motor cable between the control assem- bly and the orbital dispenser, do the following:
0/7%2 3500,9 !54/-!4)##/.42/,

0/7%2 -/4/2&!5,4 25.
Motor Control Cable (15 ft)
-!). 25.%.!",%
#/.42/,3%,%#4
-!.5!,30%%$#/.42/,
!54/-!4)# -!.5!,
Motor Control Cable (55 ft)
Installing Cable Assemblies · ti0657B

Automatic control cable receptacle

Always make connections to the control assembly with power turned off.
The PrecisionSwirl control assembly is provided with a 9–pin receptacle for the robot interface cable.
Any wiring from an external source, such as a robot controller, must follow the robot manufacturer’s instructions and must comply with the appropriate codes and standards.
To connect the automatic control cable (P/N 617829) between the control assembly and the robot, perform the following steps:

Enable The 24V enable signal starts the orbital dis- penser motor.
This 0-10 VDC analog signal is used to adjust the motor speed. (0-10 VDC = 6600-24,000 RPM)
The alarm relay activates when the motor speed drops below 1500 RPM or does not start. The relay contacts are normally closed.
A fault will be generated if any of the front panel controls are in the wrong position for automatic operation
This analog signal can be used to monitor motor speed. (0-10 VDC = 0-24,000 RPM)
For information about specific control assembly circuitry and connections, read the chart below and see the Wir- ing Diagrams on pages 56 and 57, and FIG. 11.

Installing Cable Assemblies · ti0827A

Verifying Ground Continuity
Verify ground continuity between:
The PrecisionSwirl orbital dispenser is calibrated at the factory. No adjustment is required during initial setup.
Before applying power, read the reference information provided about controls and indicators to become famil- iar with the equipment.
Inspect the orbital dispenser cables, material, and air hoses daily for leakage and other visible damage.
FIRE AND EXPLOSION HAZARD To reduce the risk of a fire, explosion, and serious injury, proper electrical grounding of every part of your system is essential. Read the warning section, FIRE AND EXPLOSION HAZARD, on page 5 and follow the grounding instructions below.
The following grounding instructions are minimum requirements for a basic dispensing system. Your sys- tem may include other equipment or objects which must be grounded. Check your local electrical code for detailed grounding instructions for your area and type of equipment. Your system must be connected to a true earth ground.
Verifying Ground Continuity

Reading the PrecisionSwirl Control Assembly Controls and Indicators
Table 1 describes the controls on the PrecisionSwirl control assembly. See FIG. 12 for an illustration of the controls and indicators.
Table 1. Control Assembly Controls
Button/Switch What it does
MAIN ON/OFF Switch Controls power to the system.
Control Select Switch AUTOMATIC / MANUAL
Switches the orbital dispenser to automatic or manual control.
RUN / ENABLE Button Pushing the RUN/ENABLE (black) button starts the orbital dispenser motor in manual mode or enables the motor to be started in automatic mode.
STOP Button Pushing the STOP (red) button removes power from the orbital dispenser.
MANUAL SPEED CONTROL Knob (potentiometer)
Regulates the motor speed of the orbital dispenser in the manual control mode.
Table 2 describes the indicators on the PrecisionSwirl control assembly. See FIG. 12 for an illustration of the controls and indicators.
Table 2. Control Assembly Indicators
Indicator Light is Meaning
POWER (white ON Power is on.
OFF Power is off.
RUN (green) ON PrecisionSwirl orbital dispenser is ready for operation, or is operating in manual control mode.
OFF PrecisionSwirl orbital dispenser is not ready for operation, or is not operating in manual control mode.
MOTOR FAULT (red) ON Motor is not rotating. Or, the motor is rotating below the mini- mum speed.
OFF Motor is functioning properly.
PrecisionSwirl Module Operation · Button/Switch

0/7%2 -/4/2&!5,4 25.
-!).
25.%.!",%
#/.42/,3%,%#4
-!.5!,30%%$#/.42/,
!54/-!4)# -!.5!,
Setting Operation Modes
Material flow rate and “ON/OFF” flow are not con- trolled by the PrecisionSwirl orbital dispenser. These must be controlled by the other interfaces. Contact your Graco Distributor for assistance.
The PrecisionSwirl module has two operating states:
The PrecisionSwirl orbital dispenser is in an idle state until you press the RUN/ENABLE button on the control assembly. The only time the PrecisionSwirl orbital dis- penser can swirl material is when the RUN/ENABLE button is pressed in either Automatic or Manual mode. When the STOP button is pressed, the PrecisionSwirl orbital dispenser becomes idle and will not swirl mate- rial.
The procedures in this section configure the module for manual or automatic operation.
PrecisionSwirl Module Operation

The system is now ready to dispense. Make sure dispensing will not endanger people or equipment before proceeding.
To put the PrecisionSwirl module into Automatic mode:
You are about to place the system under robotic control. Make sure dispensing will not endanger people or equipment before proceeding.
The PrecisionSwirl orbital dispenser motor starts imme- diately.
To stop manual swirling and idle the module:
The PrecisionSwirl orbital dispenser is now disabled and will stop swirling material.
The PrecisionSwirl orbital dispenser is now enabled. When it receives a 24 Volt RUN/ENABLE command from the robot, the PrecisionSwirl orbital dispenser motor starts and reaches full speed in about one sec- ond. The orbital dispenser motor stops when the 24 Volt RUN/ENABLE command is removed.
Circuitry on the relay board monitors the motor speed to verify that the motor is functioning properly.
When the motor functions improperly, the circuitry on the relay board activates the motor fault alarm. The alarm turns on when:
To leave Automatic dispense mode and idle the module:
When a fault occurs, the motor fault light on the control panel illuminates, and the alarm relay activates sending the fault signal out via the automatic control cable. The alarm remains turned on until the fault condition is cor- rected or the run command is removed.
A fault will also be generated if any of the front panel controls are not in the correct position for automatic operation (power switch, enable switch, manual/auto switch).

Adjust the orbital dispenser motor speed in the manual or automatic control mode as described in the following para- graphs.
Manual Mode:
Automatic Mode:
Adjust motor speed by rotating the MANUAL SPEED CONTROL knob on the control box. See FIG. 12.
Use the motor speed chart (FIG. 13) to find the voltage setting required to achieve the desired motor speed. When the control signal voltage is increased, the motor speed increases. When the control signal voltage is decreased, the motor speed decreases.
Rotate the knob clockwise to increase speed and coun- terclockwise to decrease speed. Use the motor speed chart (FIG. 13) to find the manual control setting required to achieve the desired motor speed.
Exceeding the maximum analog speed control volt- age may result in damage to the motor controller.
PrecisionSwirl Motor Speed Command
SPEED IN RPM x 1000
0 0 1 2 3 4 5 6 7 8 9
Analog speed signal from robot (Volts dc)
OR Manual control setting
PrecisionSwirl Module Operation

Some solutions require disassembling the dispense valve or orbital dispenser. Always relieve system pressure before performing these procedures.
Table 3 provides troubleshooting information. For other troubleshooting situations, call your Graco distributor.
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pres- sure Relief Procedure (see manual 309043). To reduce the risk of serious injury whenever you are instructed to remove, change, check, clean, or han- dle the nozzle in any manner, always disconnect the motor control cable from the control assembly (see FIG. 8 on page 17), or place the control assembly in the MANUAL mode of operation using the CON- TROL SELECT switch. (See FIG. 12 on page 22.)
Table 3. Troubleshooting
No material being dispensed Clogged nozzle Change nozzle.
No material or pressure Check fluid delivery system.
Broken or clogged dispense tube Rebuild the orbital dispenser.
Fault in dispense valve Refer to Dispense Valve manuals 308876 or 309376.
Material dispensing but not swirling (Motor fault light is on)
Motor not operating Check wiring connections and cable.
Tube bearing defective; replace tube bearing.
Motor defective; replace motor.
Check for fluid leak.
Control assembly failure Check analog voltage control setting and enable signal.
Check RPM setting.
Check power and fuses.
Check wiring.
Orbiter bearing failure Replace bearing.
Material dispensing but not swirling
Material accumulating on nozzle Clean nozzle.
(Motor fault light is off)
Motor is rotating but poor swirl pat- tern or change in bead size
Flow rate has changed Check flow rate.
Motor speed has changed Check analog speed signal.
Material viscosity has changed Check material parameters.
Partially clogged nozzle Clean nozzle.
Troubleshooting · Problem Cause Solution

Servicing the Control Assembly
This part of the manual provides information about the following control assembly components:
Refer to the Parts information on pages 34, 36, and 38 while servicing the control assembly.
Lamp Button and Switch Removal
Remove the light bulb as follows:
ELECTROCUTION HAZARD Installing and servicing this equipment requires access to parts which could cause an electric shock or other serious injury. Have only qualified electricians access the control assembly.
ELECTROCUTION HAZARD Installing and servicing this equipment requires access to parts which could cause an electric shock or other serious injury. Have only qualified electricians access the control assembly.
Replace the light bulb as follows:
Control Assembly Service

MAIN Power Switch Replacement
Remove the MAIN power switch as follows:

Replace the MAIN power switch as follows:
ELECTROCUTION HAZARD Installing and servicing this equipment requires access to parts which could cause an electric shock or other serious injury. Have only qualified electricians access the control assembly

Control Assembly Service

Potentiometer Replacement
Remove the potentiometer as follows:
Replace the potentiometer as follows:
ELECTROCUTION HAZARD Installing and servicing this equipment requires access to parts which could cause an electric shock or other serious injury. Have only qualified electricians access the control assembly.
Terminals 1 and 3
2172 8034B

This part of the manual provides information about the following panel assembly components:

*

Swirl Control Board Replacement
Remove the relay board as follows:
Replace the relay board as follows:
ELECTROCUTION HAZARD Installing and servicing this equipment requires access to parts which could cause an electric shock or other serious injury. Have only qualified electricians access the control assembly.
Panel Assembly Service

RFI Filter Replacement
Remove the RFI Filter as follows:
Replace the RFI filter as follows:
ELECTROCUTION HAZARD Installing and servicing this equipment requires access to parts which could cause an electric shock or other serious injury. Have only qualified electricians access the control assembly.
Panel Assembly Service

Relay Replacement
Remove the relay as follows:
Replace the relay as follows:

Relays are always P/N 15A797, 24 VDC. If the robot run command signal for automatic control mode is 24 VDC, then relay is also P/N 15A797.
ELECTROCUTION HAZARD Installing and servicing this equipment requires access to parts which could cause an electric shock or other serious injury. Have only qualified electricians access the control assembly.

*
Panel Assembly Service

Remove the fuse as follows:

Replace the fuse as follows:
Check the new fuse (24) to ensure that it matches the Amp rating of the failed fuse.
ELECTROCUTION HAZARD Installing and servicing this equipment requires access to parts which could cause an electric shock or other serious injury. Have only qualified electricians access the control assembly.

*
Lift the top of the fuse holder to unlock
Fuse location (2 places)
Panel Assembly Service

Ref. No. Part No. Description Qty. 1 241487 CABINET, PrecisionSwirl 1 2 194896 LABEL, front panel, 1 3 241580 PANEL, ASSY, control 1 4 241600 CONNECTOR, motor 1 5 617771 GASKET, flange, electrical connec- tor, #14
6 241599 CONNECTOR, robot 1 8 C19949 SCREW, SHC, #4-40 x 0.25 4 9 115237 SWITCH, power, rotary 1 13 617777 LIGHT base, direct supply 2 14 617778 LENS, light, white, 7/8 1 15 617779 LENS, light, green, 7/8 1 16 617780 LAMP, incandescent, 24V 2 17 617781 SWITCH BASE, 1-NO, 1-NC 2 18 617782 ACTUATOR, switch, 2–PB, rect 1 19 617783 ACTUATOR, switch, 2 position 1 20 617775 POTENTIOMETER, 10 turn, 10K ohm, 0.5W
21 617776 DIAL, vernier, 15 turn 1 22† 113285 TERMINAL, ring, #10 2 23† 100718 WASHER 2 24† 617774 NUT, hex, #10-32, brass 4 31 194897 LABEL, cable connector 1 32▲† 617472 LABEL, danger, electric shock 1 34† C19738 SCREW, drive, round head 4 35 C78216 CLAMP, ty–rap 10 36 C78321 TIE, cable, 3.62 long 18 42 100731 WASHER 4 43 100133 WASHER, lock 4 44† 100307 NUT, full, hex 4 45 195899 DUCT, wire, 10 in. 1 47† 114887 KEY, latch, door 1 51 115217 SCREW, female, kit 1 52 194984 COVER, wire, duct, 10 in. 1 53 115434 LENS, light, red, 7/8 1
† These parts are not shown on the parts drawing.
▲Replacement Danger and Warning labels, tags, and
cards are available at no cost.
Control Assembly Parts

POWER MOTOR FAULT RUN
MAIN RUN / ENABLE
CONTROL SELECT
MANUAL SPEED CONTROL
AUTOMATIC MANUAL
8037B
8, 4, 5 6, 51 46
0/7%2 3500,9 !54/-!4)##/.42/,

13, 53, 16 13, 15, 16
'.$
36 45, 48 52 17, 19 35

'.$
'.$
'.$
'.$
,. 0%
6!# 0( (:

Ref. No. Part No. Description Qty.
Ref. No. Part No. Description Qty. 1 194693 PLATE 1 2 115215 POWER SUPPLY 1 3 194895 RAIL, mount 2 5 244355 BOARD, swirl control 1 7 102410 SCREW, cap, socket head 2 8 100272 WASHER, lock, internal tooth 2 9 112443 BLOCK, terminal, ground 8 10 514556 HOLDER, fuse 2 11 115234 COVER, terminal 1 12 112446 BLOCK, clamp, end 7 13 112442 BLOCK, terminal 23
14 103833 SCREW, machine, bdgn 12 15 115212 FILTER, RFI 1 16 194894 DUCT, wire 1 21 194976 LABEL, wiring 1 22 100718 WASHER 12 23† 115130 JUMPER PIN 1 24† 115216 FUSE, 2 AMP High Interrupting 2 26 194985 COVER, wire, duct, 14 in. 1
† These parts are not shown on the parts drawing.

*
2 11 10, 26 9
Control Assembly Parts · 7, 8

Control Assembly Parts

Motor Control Cable Assemblies
Table 5. Motor Control Cables
The motor control cables that are provided with the module are OLFLEX® brand cables. The 55 ft (16.8) motor cable (617870) can be used alone.
Part Number Length Description
617870 55 ft (16.8 m) Motor cable assembly
FUNCTION V+ SENSOR 1 SENSOR 2 SENSOR 3 V- SHIELD TIED TO CONNECTOR SHELL SHIELD TIED TO CONNECTOR SHELL
A B C D E
WHITE BROWN GREEN YELLOW
GREY
H J K L M
H J K L M
RED 1 RED 2 RED 3 GREEN/YELLOW
MOTOR PH. A MOTOR PH. B MOTOR PH. C GROUND
Accessory Parts

Table 6. Motor Control Cables
Part Number Length Description
For robot applications that have a lot of torsional motion to the cable in addition to bending. These cables are made from Olflex 900 series robot cable that are designed to handle more torsional loads. The cables must be used in conjunction with the 55 ft motor cable.
233125 6 ft (1.8 m) Motor cable assembly
233124 9 ft (2.7 m) Motor cable assembly
233123 15 ft (4.6 m) Motor cable assembly
FUNCTION V+ SENSOR 1 SENSOR 2 SENSOR 3 V-
A B C D E
WHITE BROWN GREEN YELLOW
GREY
H J K L M
H J K L M
MOTOR PH. A MOTOR PH. B MOTOR PH. C GROUND
CONNECTION DIAGRAM
Accessory Parts

The length of robot interface cable assembly 617829 is 40 ft (12.2 m). FIG. 26 shows the 9-pin cable and identi- fies the cable interface signals.
REFERENCE FUNCTION
SHIELD
RED GREEN BLACK GREEN/BLACK
1 2 3 4 5 6 7 8 9
0-10 VDC ACTUAL SPEED SIGNAL DC COMMON NOT USED RUN COMMAN SIGNAL ALARM RELAY IN ALARM RELAY OUT NOT USED RUN COMMAND NEUT/COM
BLUE WHITE/BLACK
WHITE
CONNECTION DIAGRAM
Dispenser Valve Adapter Fittings
Ref. No. Part No. Description Qty. 1 197504 Straight flange adapter, EnDure 1 2 197842 45 degree nosepiece 1 3 198323 Alternative orbiter nut 1 4 198324 Fitting, nosepiece to orbiter 1
45 degree orbiter mount uses reference numbers 2-4.
Accessory Parts

Motor Controller Wiring, Lines 200-238
6!# (:
,.
,.
'.$
,.
'.$
,.
2/"/4 !.!,/'
!54/ #2
-!.5!, .#
25.%.!",%

-/4 *
'.$ -0 -
25..%5#/-
%84%2.!, !54/-!4)#
#/.42/,
'2!#/37)2,#/.42/,
).054
25.6
!,!2-2%,!9).

Control Assembly Input power 100 - 240 Vac, 50/60Hz, 1 PH Output power Proprietary PWM voltage to the motor, less than 24V Automatic control analog input 0-10 VDC for 6600-24,000 RPM Speed signal output 0-10 VDC for 0-24,000 RPM Auto control relay contact rating 3 Amps at 30 VDC Weight 23.5 lbs (10.7 kg)
Orbital Dispenser Input power Proprietary PWM voltage to the motor, less than 24V Motor torque 1.5 oz–in. Maximum motor speed 24,000 RPM Maximum operating pressure 3500 psi (241 bar, 24.1 MPa) Fluid inlet 3/4-16 37° JIC female swivel Nozzle attachment #10-32 proprietary connection Wetted components Stainless steel, nickel alloy, brazing alloy, epoxy, EPDM
rubber Noise levels Sound pressure level - 67 dBa Weight 1.6 lbs (0.7 kg)
PrecisionSwirl™ is a trademark of Graco, Inc.
PARKER O LUBE™ is a trademark of Parker Hannifin Corp.
Loctite® is a registered trademark of the Loctite Corporation.
Technical Data

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
This manual contains English. MM 310554
Copyright 2001, Graco Inc. is registered to ISO 9001
www.graco.com Revised 11/2009
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| No material being dispensed | Clogged nozzle | Change nozzle. | p.25 |
| No material being dispensed | No material or pressure | Check fluid delivery system. | p.25 |
| No material being dispensed | Broken or clogged dispense tube | Rebuild the orbital dispenser. | p.25 |
| No material being dispensed | Fault in dispense valve | Refer to Dispense Valve manuals 308876 or 309376. | p.25 |
| Material dispensing but not swirling (Motor fault light is on) | Motor not operating | Check wiring connections and cable. | p.25 |
| Material dispensing but not swirling (Motor fault light is on) | Tube bearing defective; replace tube bearing. | p.25 | |
| Material dispensing but not swirling (Motor fault light is on) | Motor defective; replace motor. | p.25 | |
| Material dispensing but not swirling (Motor fault light is on) | Check for fluid leak. | p.25 | |
| Material dispensing but not swirling (Motor fault light is on) | Control assembly failure | Check analog voltage control setting and enable signal. | p.25 |
| Material dispensing but not swirling (Motor fault light is on) | Check RPM setting. | p.25 | |
| Material dispensing but not swirling (Motor fault light is on) | Check power and fuses. | p.25 | |
| Material dispensing but not swirling (Motor fault light is on) | Check wiring. | p.25 | |
| Material dispensing but not swirling (Motor fault light is on) | Orbiter bearing failure | Replace bearing. | p.25 |
| Material dispensing but not swirling (Motor fault light is off) | Material accumulating on nozzle | Clean nozzle. | p.25 |
| Motor is rotating but poor swirl pat- tern or change in bead size | Flow rate has changed | Check flow rate. | p.25 |
| Motor is rotating but poor swirl pat- tern or change in bead size | Motor speed has changed | Check analog speed signal. | p.25 |
| Motor is rotating but poor swirl pat- tern or change in bead size | Material viscosity has changed | Check material parameters. | p.25 |
| Motor is rotating but poor swirl pat- tern or change in bead size | Partially clogged nozzle | Clean nozzle. | p.25 |
Owners and our team usually reply within a day — and your question helps the next person too.