Check-Mate ® Pump Packages
For use with non-heated bulk supply of medium to high viscosity sealant and adhesive materials. For professional use only.
Not approved for use in European explosive atmosphere locations.
See page 3 for model information. See page 32 for maximum working pressure and approvals.


Related Manuals
Related Manuals 2 Models 3 Warnings 4 Component Identification, Supply Unit Installation 6 Component Identification, Typical Installation . . . 8 Installation 9
:
Grounding 9 System Accessories 10 Setup 11
Wet Cup 11 Pressure Relief Procedure 12 Prime/Flush 13 Start Up and Adjust Pump 13 Shutdown 15
Overnight Shutdown 15 Troubleshooting 16 Repair 18
Disconnect Displacement Pump 18 Reconnect Displacement Pump 20 Parts 22
23 Pump Packages with L060xx Displacement Pumps
24 Pump Packages with L100xx Displacement Pumps
26 Pump Packages with L200xx Displacement Pumps
27 Pump Packages with L250xx Displacement Pumps
28 Pump Packages with L500xx Displacement Pumps
29 Dimensions 30 Technical Data 32 Performance Charts 33 Graco Standard Warranty 40 Graco Information 40
Related Manuals

Check your pump package’s identification (ID) plate (located on side of air motor) for the 6-digit part number of your pump package. Use the following matrix to define the construction of your pump package, based on the six dig- its. For example, pump package P29RSM represents the pump package (P); a pressure ratio of 29:1 with an NXT3400 motor and a 250cc displacement pump (29); a low noise motor with remote DataTrak (R); and a displacement pump constructed of stainless steel (S) with MaxLife® coatings, packings, and enclosed wet cup (M).
MAX AIR WPR RATIO MAX FLUID WPR
ID plate located on side of air motor.
Some configurations in the following matrix cannot be built. See the Product Selection Guide for available systems.
To order replacement parts, see Parts section starting on page 22. The digits in the matrix do not correspond to the Ref. Nos. in the Parts drawings and lists.
Models · Artwork 293287

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbol refers to procedure-specific risk. Refer back to these warnings. Additional, product-specific warnings may be found throughout the body of this manual where applicable.


Component Identification, Supply Unit Installation

E
M
U
A
B
Y
G
T
S
K
R
F
J
D P
F IG . 1
Key: A Ram Assembly B Air Motor C Check-Mate Displacement Pump D Platen E Remote DataTrak (single systems) or Display Module (tandem systems) F Fluid Control Module (tandem systems only; under shroud) G Air Control Module J Platen Bleed Port K Power Supply Box L Blowoff Air Supply Line
M Lift Rod P Pump Bleed Valve R Wet Cup S Fluid Line (not supplied) T Air Line (not supplied) U Air Line Drain Valve (not supplied) V Air Filter (not supplied) W Air Shutoff Relief Valve (for accessories, not supplied) X Drum Low/Empty Sensor Y Air Motor Solenoid
CM14BA Model Shown

Component Identification, Supply Unit Installation

Key: BA Elevator Cart BB Air Motor BC Displacement Pump BD Platen BF Elevator and Pump Air Controls J Platen Bleed Port P Pump Bleed Valve R Wet Cup (behind air controls)

Component Identification, Typical Installation

U
AA
AC
R
AH
AJ
P
AK
AB
AF
AE
F IG . 3
Key: AA Air Motor AB Coupling Assembly AC Tie Rods AE Displacement Pump AF Fluid Outlet AG Fluid Inlet (not shown) AH Air Regulator AJ Bleed Type Air Motor Valve
AK Pump Runaway Valve P Pump Bleed Valve R Wet Cup U Air Line Drain Valve (not supplied) V Air Filter (not supplied) W Air Shutoff Relief Valve (for accessories, not supplied)
P40RCM Model Shown

Grounding
The equipment must be grounded. Grounding reduces the risk of static and electric shock by providing an escape wire for the electrical current due to static build up or in the event of a short circuit.
Pump: use a ground wire and clamp. Loosen the grounding lug locknut and washer. Insert one end of a 1.5 mm2 (12 ga) minimum ground wire into the slot in lug and tighten the locknut securely. Connect the other end of the wire to a true earth ground. Order Part 237569 Ground Wire and Clamp.

Air and fluid hoses: use only electrically conductive hoses.
Air compressor: follow manufacturer's recommenda- tions.
Spray gun/dispense valve: ground through connection to a properly grounded fluid hose and pump.
Fluid supply container: follow your local code.
Object being sprayed: follow your local code.
Solvent pails used when flushing: follow local code. Use only conductive metal pails, placed on a grounded surface. Do not place the pail on a nonconductive sur- face, such as paper or cardboard, which interrupts grounding continuity.
To maintain grounding continuity when flushing or relieving pressure: hold metal part of the spray gun/dispense valve firmly to the side of a grounded metal pail, then trigger the gun/valve.
Installation

A main air bleed valve and pump bleed valve (P) are required. These accessories help reduce the risk of serious injury, including fluid injection and splashing of fluid in the eyes or on the skin, and injury from moving parts if you are adjusting or repairing the pump.
The main air shutoff valve shuts off the air to the pump and ram. The air motor valve relieves air trapped between this valve and the pump after the air is shut off. Trapped air can cause the pump to cycle unexpect- edly. Locate the valve close to the pump.
The pump bleed valve assists in relieving fluid pressure in the displacement pump, hose, and gun/valve. Trig- gering the gun/valve to relieve pressure may not be sufficient.
If using Check-Mate pump with Graco Supply Sys- tems, refer to Supply Systems Operation manual for system accessory installation instructions.
Install the following accessories as listed. Refer to FIG. 2 to see fluid line accessories represented in a typical supply unit installation.
For use with all other systems, use this section for accessory installation instructions.
Be sure all air lines (T) and fluid lines (S) are properly sized and pressure-rated for your system. Use only electrically conductive hoses. Fluid hoses must have spring guards on both ends.
Mount the pump package to suit the type of installation planned. Pump dimensions are shown on page 30. Refer to Check-Mate Displacement Pump manual 312375 for mounting hole layout.
Install the following accessories as listed. Refer to FIG. 1 to see air line accessories represented in a typical sup- ply unit installation.

Wet Cup
To torque the wet cup, use the following steps.
Before starting, fill the wet cup (R) 1/3 full with Graco Throat Seal Liquid (TSL) or compatible solvent.
The enclosed wet cup has a fill port in the cover.
The wet cup is torqued at the factory; however, throat packing seals on Severe Duty pumps may relax over time. Check wet cup torque frequently after initial start-up and periodically after the first week of produc- tion. Maintaining proper wet cup torque is important to extending seal life.

MaxLife pumps use a special u-cup throat seal that is non-adjustable and does not require periodic torquing.
Setup

a. Close the air motor slider valve and the main air slider valve.
b. Set the ram director valve to DOWN. The ram will slowly drop.
c. Jog the director valve up and down to bleed air
from ram cylinders.


a. Close the air motor valve and the elevator direc- tor valve. The ram will slowly drop.
If you suspect that the spray tip/nozzle or hose is com- pletely clogged, or that pressure has not been fully relieved after following the steps above, very slowly loosen the tip guard retaining nut, nozzle, or hose end coupling and relieve pressure gradually, then loosen completely. Now clear the tip/nozzle or hose.

Start Up and Adjust Pump
Keep hands and fingers away from the priming piston during operation and whenever the pump is charged with air. The priming piston extends beyond the intake housing to pull material into the pump and can ampu- tate a hand or finger caught between it and the intake housing. Follow the Pressure Relief Procedure on page 12 before checking, clearing, or cleaning the priming piston.
The pump is tested with lightweight oil, which is left in to protect the pump parts. If the fluid you are using may be contaminated by the oil, flush it out with a compatible solvent before using the pump.
Flush with a fluid that is compatible with the fluid you are pumping and with the wetted parts in your system. Check with your fluid manufacturer or supplier for rec- ommended flushing fluids and flushing frequency. Always flush the pump before fluid dries on the displace- ment rod.
a. Set ram air regulator to about 50 psi (3.5 bar).
b. Set the ram director valve to down.




a. Close elevator director valve. The ram will slowly drop.
b. If necessary, press blowoff push button to pause elevator descent.
When changing fluid containers with the hose and gun/valve already primed, open the pump bleed valve (P), to help prime the pump and vent air before it enters the hose. Close the valve when all air is eliminated.

CAUTION Do not allow the pump to run dry. It will quickly accel- erate to a high speed, causing damage. If your pump is running too fast, stop it immediately and check the fluid supply. If the container is empty and air has been pumped into the lines, refill the container and prime the pump and the lines, or flush and leave it filled with a compatible solvent. Eliminate all air from the fluid system.

To reduce the risk of fluid injection, do not use your hand or fingers to cover the bleed hole on the under- side of the bleed valve body (P) when priming the pump. Use the handle or a crescent wrench to open and close the bleed plug. Keep your hands away from the bleed hole.
Always use lowest possible fluid pressure to bleed air out of pump.



Pump fails to operate. Restricted line or inadequate air sup- ply; closed or clogged valves.
Clear; increase air supply. Ensure that all valves are open. Obstructed fluid hose or gun/valve; fluid hose ID is too small.
Open, clear*; use a hose with a larger ID.
Fluid dried on displacement rod. Clean. Always stop pump at bottom of stroke. Keep enclosed wet cup 1/3 filled with a compatible solvent. Dirty, worn, or damaged motor parts. Clean or repair; see separate motor man- ual. Runaway occurred. See runaway section of Supply Units Oper- ation manual 313526. Pump operates but output is low on both strokes.
Restricted line or inadequate air sup- ply; closed or clogged valves.
Clear; increase air supply. Ensure all valves are open. Increase air pressure to ram for better load- ing. Obstructed fluid hose or gun/valve; fluid hose ID is too small.
Open, clear*; use a hose with a larger ID.
Bleed-type air valve is partially open. Close bleed-type air valve. Air is leaking into supply container. Check ram plate seal. Fluid is too heavy for pump priming. Use drain/purge valve. Use a ram. See Supply Units Operation manual 313526. Held open or worn intake valve or seals.
Clear valve; replace seals. See separate Check-Mate Displacement Pump manual 312375. Worn packings in displacement pump. Replace packings. See separate Check-Mate Displacement Pump manual 312375. Pump operates, but output is low on downstroke.
Fluid is too heavy for pump priming. Use drain/purge valve. Use a ram. See Supply Units Operation manual 313526. Held open or worn intake valve or seals.
Clear valve. Replace seals. See separate Check-Mate Displacement Pump manual 312375. Pump operates, but output is low on upstroke.
Held open or worn intake valve or seals.
Clear valve. Replace seals. See separate Check-Mate Displacement Pump manual 312375.
Troubleshooting · Problem Cause Solution

Erratic or accelerated pump speed.
Exhausted fluid supply. Refill and prime. Fluid is too heavy for pump priming. Use drain/purge valve. Use a ram. See Supply Units Operation manual 313526. Increase ram air pressure. Held open or worn intake valve or seals.
Clear valve. Replace seals. See separate Check-Mate Displacement Pump manual 312375. Held open or worn priming piston. Clear; service. See separate Check-Mate Displacement Pump manual 312375. Worn packings in displacement pump. Replace packings.See separate Check-Mate Displacement Pump manual 312375.
* To determine if fluid hose or gun is obstructed, follow Pressure Relief Procedure, page 12. Disconnect fluid hose and place a container at pump fluid outlet to catch any fluid. Turn on air just enough to start pump. If pump starts when air is turned on, the obstruction is in the fluid hose or gun.
Troubleshooting · Problem Cause Solution

If your system includes a remote DataTrak, discon- nect the air motor harness from the motor as well.

Keep hands and fingers away from the priming piston during operation and whenever the pump is charged with air to reduce the risk of injury. On the pump down- stroke the priming piston extends beyond the intake housing to pull the material into the pump. The priming piston works under extreme force. During operation and whenever the pump is charged with air, the priming piston can severely injure or amputate a hand or finger, or break a tool, caught between it and the intake hous- ing. Always relieve the pressure before checking, clear- ing, cleaning, flushing, or servicing any part of the pump.

On Premier air-powered pumps, the rocker arms (located beneath the rocker arm covers) move when air is supplied to the motor. Never operate the pump with the rocker arm covers removed.

CAUTION Be sure to use at least two people when lifting, mov- ing, or disconnecting the pump. This pump is too heavy for one person. If you are disconnecting the dis- placement pump from a motor that is still mounted (for example, on a ram), be sure to support the displace- ment pump while it is being disconnected, to prevent it from falling and causing injury or property damage. Do this by securely bracing the displacement pump, or by having at least two people hold it while another disconnects it.



Repair

CAUTION Be sure to use at least two people when lifting, mov- ing, or connecting the pump. This pump is too heavy for one person. If you are connecting the displace- ment pump to a motor that is still mounted (for exam- ple, on a ram), be sure to support the displacement pump while it is being connected, to prevent it from falling and causing injury or property damage. Do this by securely bracing the displacement pump, or by having at least two people hold it while another con- nects it.

On Premier models, ensure that the rod adapter (6) has not loosened during maintenance. Proper torque is necessary to prevent the rod adapter from loosening during the pump operation.
If the rod adapter (6) has loosened during mainte- nance, remove the adapter and apply Loctite 2760 (or equivalent) to the rod adapter and air motor pis- ton threads, and then torque to 230-250 ft-lbs (312-340 N•m).
60cc 75-80 ft-lbs (102-108 N•m)
500cc 230-250 ft-lbs (312-340 N•m)


Repair · Displacement Pump Torque

Repair



Parts

Model P39LCS Shown Model P40RCM Shown



Torque to 50-60 ft-lb (68-81 N•m)
Torque to 124-155 ft-lb (196-210 N•m)
Torque to 230-250 ft-lbs (312-340 N•m)

Ref. Part Description Qty. 3 171313 ROD, tie 3 5 100681 NUT, jam, hex 3 7 184128 COUPLING, assy. 1
Ref. Part Description Qty.
8 15T311 COUPLER, cover 1 11 257663 ADAPTER, rod 21 100186 WASHER, lock, internal tooth 1 23 112887 WRENCH, spanner; not shown 1 25 15V909 SCREW, ground 1
Reference Number and Description
1 2 4 6 14 16 17 18
Reed Assy. Switch Screw
C38267 (3) 15M675 112339 NA NA 100133 P05LCM M02LN0 L060CM
P05LSM M02LN0 L060SM
P11LCS M04LN0 L060CS
P11LCM M04LN0 L060CM
NA NA
P11LSS M04LN0 L060SS
P11LSM M04LN0 L060SM
P11RCS M04LN0 L060CS
P11RCM M04LN0 L060CM
C38267 (6) 15M675 121843
NA
P11RSS M04LN0 L060SS
P11RSM M04LN0 L060SM
24A032 15V719
P11SCS M04LH0 L060CS
P11SCM M04LH0 L060CM
P11SSS M04LH0 L060SS
P11SSM M04LH0 L060SM
P20LCS M07LN0 L060CS
P20LCM M07LN0 L060CM
NA
P20LSS M07LN0 L060SS
P20LSM M07LN0 L060SM
C38267 (6) NA 121843
NA NA
P20RCS M07LN0 L060CS
24A032 P20RCM M07LN0 L060CM
P20RSS M07LN0 L060SS
P20RSM M07LN0 L060SM
Qty. 1 1 3 or 6 1 3 1 1 3

Reference Number and Description
1 2 4 6 14 16 17 18
Reed Assy. Switch Screw
C38267 (6) NA 121843 24A032 15V719 NA P20SCM M07LH0 L060CM
P20SSM M07LH0 L060SM
P38LCS M12LN0 L060CS
P38LCM M12LN0 L060CM
NA NA
P38LSS M12LN0 L060SS
P38LSM M12LN0 L060SM
P38RCS M12LN0 L060CS
P38RCM M12LN0 L060CM
C38267 (6) NA 121843
NA
P38RSS M12LN0 L060SS
P38RSM M12LN0 L060SM
24A032 15V719
P38SCS M12LH0 L060CS
P38SCM M12LH0 L060CM
P38SSS M12LH0 L060SS
P38SSM M12LH0 L060SM
P61LCS M18LN0 L060CS
P61LCM M18LN0 L060CM
NA NA
P61LSS M18LN0 L060SS
P61LSM M18LN0 L060SM
P61RCS M18LN0 L060CS
P61RCM M18LN0 L060CM
C38267 (6) NA 121843
NA
P61RSS M18LN0 L060SS
P61RSM M18LN0 L060SM
24A032 15V719
P61SCS M18LH0 L060CS
P61SCM M18LH0 L060CM
P61SSS M18LH0 L060SS
P61SSM M18LH0 L060SM
Qty. 1 1 3 or 6 1 3 1 1 3

Ref. Part Description Qty. 3 257360 ROD, tie 3 15K750 ROD, tie (P63DCS and P63ECS only) 3 4 108098 WASHER, lock, spring 3 5 106166 NUT, mach, hex 3
Ref. Part Description Qty.
6 15H392ROD, adapter 1 7 244819 COUPLING, assy. 1 8 197340 COUPLER, cover 1 9 244820 CLIP, hairpin with lanyard 1 20 120588 PLUG, pipe, round 1
Reference Number and Description
P40LCM N22LN0 L100CM
P40LSS N22LN0 L100SS
P40LSM N22LN0 L100SM
P40SSM N22LH0 L100SM
P40SSS N22LH0 L100SS
P40SCS N22LH0 L100CS
P40RCS N22LR0 L100CS
P40RCM N22LR0 L100CM
P40RSM N22LR0 L100SM
P40RSS N22LR0 L100SS
P63LCS N34LN0 L100CS
P63LCM N34LN0 L100CM
P63LSM N34LN0 L100SM
P63LSS N34LN0 L100SS
P63RCS N34LR0 L100CS
P63RCM N34LR0 L100CM
P63RSM N34LR0 L100SM
P63RSS N34LR0 L100SS
P63SSM N34LH0 L100SM
P63SSS N34LH0 L100SS
P63MCS N34LT0 L100CS
P63DCS N34DN0 L100CS
P63ECS N34DT0 L100CS
Qty. 1 1

Ref. Part Description Qty. 4 108098 WASHER, lock, spring 3 5 106166 NUT, mach, hex 3 20 120588 PLUG, pipe, round 1
Reference Number and Description
1 2 3 6 7 8 9 11 12
ment Pump (see 312375)
Screw, cap head P23LCS N22LN0 L200CS
assy.
P23LCM N22LN0 L200CM P23LSS N22LN0 L200SS P23LSM N22LN0 L200SM P23RCS N22LR0 L200CS P23RCM N22LR0 L200CM P23RSS N22LR0 L200SS P23RSM N22LR0 L200SM P36LCS N34LN0 L200CS
P36LCM N34LN0 L200CM P36LSS N34LN0 L200SS P36LSM N34LN0 L200SM P36RCS N34LR0 L200CS P36RCM N34LR0 L200CM P36RSS N34LR0 L200SS P36RSM N34LR0 L200SM P68LCS N65LN0 L200CS
P68LCM N65LN0 L200CM P68LSS N65LN0 L200SS P68LSM N65LN0 L200SM P68RCS N65LR0 L200CS P68RCM N65LR0 L200CM P68RSS N65LR0 L200SS P68RSM N65LR0 L200SM P68MCS N65LT0 L200CS P68SCS N65LH0 L200CS P68DCS N65DN0 L200CS 15K750 P68ECS N65DT0 L200CS Qty. 1 1 3 1 3

Ref. Part Description Qty. 4 108098 WASHER, lock, spring 3 5 106166 NUT, mach, hex 3 20 120588 PLUG, pipe, round (NXT3400 and NXT6500 motors only)
Reference Number and Description
1 2 3 6 7 8 9 10
ment Pump (see 312375)
Motor (see 311238 or
Coupler (Premier only) P29LCS N34LN0 L250CS
assy.
P29LCM N34LN0 L250CM P29LSS N34LN0 L250SS P29LSM N34LN0 L250SM P29RCS N34LR0 L250CS P29RCM N34LR0 L250CM P29RSS N34LR0 L250SS P29RSM N34LR0 L250SM P29MCS N34LT0 L250CS P29DCS N34DN0 L250CS 15K750 P29ECS N34DT0 L250CS P55LCS N65LN0 L250CS
P55LCM N65LN0 L250CM P55LSS N65LN0 L250SS P55LSM N65LN0 L250SM P55RCS N65LR0 L250CS P55RCM N65LR0 L250CM P55RSS N65LR0 L250SS P55RSM N65LR0 L250SM P55MCS N65LT0 L250CS P55DCS N65DN0 L250CS 15K750 P55ECS N65DT0 L250CS P82LCS 222800 L250CS
184381 15H392 244819 197340 244820 15M631 P82LCM 222800 L250CM P82LSS 222800 L250SS P82LSM 222800 L250SM Qty. 1 1 3 1

Ref. Part Description Qty. 4 108098 WASHER, lock, spring 3 5 106166 NUT, mach, hex 3 20 120588 PLUG, pipe, round (NXT3400 and NXT6500 motors only)
Reference Number and Description
1 2 3 6 7 8 9 10
ment Pump (see 312375)
Motor (see 311238 or
Coupler (Premier only P14LCS N34LN0 L500CS
P14LCM N34LN0 L500CM P14LSS N34LN0 L500SS P14LSM N34LN0 L500SM P14RCS N34LR0 L500CS P14RCM N34LR0 L500CM P14RSS N34LR0 L500SS P14RSM N34LR0 L500SM P14MCS N34LT0 L500CS P14DCS N34DN0 L500CS 15K750 P14ECS N34DT0 L500CS P26LCS N65LN0 L500CS
P26LCM N65LN0 L500CM P26LSS N65LN0 L500SS P26LSM N65LN0 L500SM P26RCS N65LR0 L500CS P26RCM N65LR0 L500CM P26RSS N65LR0 L500SS P26RSM N65LR0 L500SM P26MCS N65LT0 L500CS P26SSS N65LH0 L500SS P26SCS N65LH0 L500CS P26DCS N65DN0 L500CS 15K750 P26ECS N65DT0 L500CS P39LCS 222800 L500CS
184381 15H370 184129 186925 N/A 15M631 P39LCM 222800 L500CM P39LSS 222800 L500SS P39LSM 222800 L500SM Qty. 1 1 3 1 2 1 1 1

Pump Packages with NXT 2200, NXT 3400, and
Pump Packages with Premier Air Motors
NXT 6500 Air Motors
B


A
D
D
Pump Packages with NXT 200, NXT 400, NXT 700,
NXT 1200, and NXT 1800 Air Motors
A
Dimensions · ti11079a ti11080a · r_p20lcs_312376_3e

Ratio (xx:1) Motor
A in. (mm)
B in. (mm)
C in. (mm)
D in. (mm)
05 NXT200 60 8.12 (206.2) 8.11 (205.9) 29.54 (750.3) 37.66 (956.6) 56 (25) 11 NXT400 60 8.28 (210.3) 8.11 (205.9) 29.54 (750.3) 37.82 (960.6) 58 (26) 14 NXT3400 500 13.70 (348.0) 14.00 (355.6) 39.13 (993.9) 52.83 (1,341.9) 152 (69) 20 NXT700 60 8.44 (214.4) 8.11 (205.9) 29.54 (750.3) 37.98 (964.7) 63 (29) 23 NXT2200 200 16.35 (415.3) 12.40 (315.0) 36.27 (921.3) 52.62 (1,336.5) 130 (59) 26 NXT6500 500 13.78 (350.0) 16.20 (411.5) 39.13 (993.9) 52.91 (1,343.9) 169 (77) 29 NXT3400 250 13.70 (348.0) 14.00 (355.6) 39.20 (995.7) 52.90 (1,343.7) 128 (58) 36 NXT3400 200 13.70 (348.0) 14.00 (355.6) 39.27 (997.5) 52.97 (1,345.4) 128 (58) 38 NXT1200 60 8.60 (218.4) 12.30 (312.4) 29.54 (750.3) 38.14 (968.8) 69 (31) 39 Premier 500 15.76 (400.3) 17.90 (454.7) 44.30 (1,125.2) 60.06 (1,525.5) 157 (71) 40 NXT2200 100 13.45 (341.6) 12.40 (315.0) 38.18 (969.8) 51.63 (1,311.4) 97 (44) 55 NXT6500 250 13.78 (350.0) 16.20 (411.5) 39.20 (995.7) 52.98 (1,345.7) 145 (66) 61 NXT1800 60 8.76 (222.5) 14.79 (375.7) 29.54 (750.3) 38.30 (972.8) 74 (34) 63 NXT3400 100 13.70 (348.0) 14.00 (355.6) 38.18 (969.8) 51.88 (1,317.8) 101 (46) 68 NXT6500 200 13.78 (350.0) 16.20 (411.5) 39.27 (997.5) 53.05 (1,347.5) 145 (66) 82 Premier 250 15.76 (400.3) 17.90 (454.7) 44.37 (1,127.0) 60.13 (1,527.3) 132 (60)

Air motor piston diameter Refer to separate air motor manual.
Stroke length 100cc, 200cc, 250cc, 500cc: 4.75 in. (120.65 mm) 60cc: 2.5 in. (63.5 mm)
Displacement pump effective area Refer to Check-Mate Displacement Pump manual 312375.
Maximum fluid operating temperature 180° F (82.3° C)
Air Inlet Size NXT200 and NXT400 air motors: 1/4 npt (f) NXT700, NXT1200, and NXT1800 air motors: 1/2 npt (f) NXT2200, NXT3400, and NXT6500 air motors: 3/4 npt (f) Premier air motor: 1.0 in. npsm
Fluid outlet size Refer to Check-Mate Displacement Pump manual 312375.
Displacement Pump weight Refer to Check-Mate Displacement Pump manual 312375.
Maximum pump speed (Do not exceed maximum recommended speed of fluid pump, to prevent premature pump wear)
Wetted parts Refer to Check-Mate Displacement Pump manual 312375.
Refer to separate motor manual for sound data and mounting hole layout.
Maximum Fluid Working Pressure and Flow Rate at Full Air Pressure (100 psi)
Flow Rate gpm (lpm)
Maximum Air Inlet Pressure psi (MPa, bar)
Pump (cc per cycle)
Pressure psi (MPa, bar) Motor
30 cpm 60 cpm
05 100 (0.7, 7.0) 500 (3.4, 34) NXT200 60 0.5 (2.0) 0.9 (3.4)
11 100 (0.7, 7.0) 1100 (7.6, 76) NXT400 60 0.5 (2.0) 0.9 (3.4)
14 100 (0.7, 7.0) 1400 (9.8, 98) NXT3400 500 4.0 (15.0) 7.8 (30.0)
20 100 (0.7, 7.0) 2000 (13.8, 138) NXT700 60 0.5 (2.0) 0.9 (3.4)
23 100 (0.7, 7.0) 2300 (16.1, 161) NXT2200 200 1.6 (6.0) 3.2 (12.0)
26 100 (0.7, 7.0) 2600 (18.2, 182) NXT6500 500 4.0 (15.0) 7.8 (30.0)
29 100 (0.7, 7.0) 2900 (20.3, 203) NXT3400 250 2.0 (7.5) 4.0 (15.0)
36 100 (0.7, 7.0) 3600 (25.2, 252) NXT3400 200 1.6 (6.0) 3.2 (12.0)
38 100 (0.7, 7.0) 3800 (26.2, 262) NXT1200 60 0.5 (2.0) 0.9 (3.4)
39 100 (0.7, 7.0) 3900 (27.3, 273) Premier 500 4.0 (15.0) 7.8 (30.0)
40 100 (0.7, 7.0) 4000 (28.0, 280) NXT2200 100 0.8 (3.0) 1.6 (6.0)
55 100 (0.7, 7.0) 5500 (38.5, 385) NXT6500 250 2.0 (7.5) 4.0 (15.0)
61 100 (0.7, 7.0) 6100 (42.1, 421) NXT1800 60 0.5 (2.0) 0.9 (3.4)
63 100 (0.7, 7.0) 6300 (44.1, 441) NXT3400 100 0.8 (3.0) 1.6 (6.0)
68 91 (0.64, 6.4) 6200 (43.4, 434) NXT6500 200 1.6 (6.0) 3.2 (12.0)
82 76 (0.53, 5.3) 6200 (43.4, 434) Premier 250 2.0 (7.5) 4.0 (15.0)

Calculate Pump Air Flow/Consumption
To calculate fluid outlet pressure (psi/MPa/bar) at a spe- cific fluid flow (gpm/lpm) and operating air pressure (psi/MPa/bar), use the following instructions and pump data charts.
To calculate pump air flow/consumption (scfm or m3/min) at a specific fluid flow (gpm/lpm) and air pres- sure (psi/MPa/bar), use the following instructions and pump data charts.
Key: Air Pressure A 100 psi (0.7 MPa, 7 bar) B 70 psi (0.5 MPa, 5.0 bar) C 40 psi (0.3 MPa, 2.8 bar) D 90 psi (0.63 MPa, 6.3 bar)
Key:Test Fluid E No. 10 weight oil F 100,000 centipoise sealant test fluid G 4,000,000 centipoise silicon test fluid H 4,000,000 centipoise weldable rubber base sealer J 8,000,000 centipoise pseudoplastic (expandable plastisal sealer (500,000 centipoise at flow conditions))
05:1 (E) Check-Mate Pumps 11:1 (E) Check-Mate Pumps
12 (0.3)
1400 (9.6, 96)
25 (0.7)
Fluid Pressure in psig (MPa, bar)
Fluid Pressure in psig (MPa, bar)
Air Flow in SCFM (m3/min)
Air Flow in SCFM (m3/min)
500 (34, 3.4)
8 (0.2)
1000 (6.8, 68)
17 (0.5)
A
B
5 (0.1)
600 (4.1, 41)
11 (0.3)
100 (0.7, 7)
2 (.06)
200 (1.4, 14)
4 (0.1)
0.2 (0.8)
0.4 (1.5)
0.6 (2.2)
0 0.8 (2.2)
0.2 (0.8)
0.4 (1.5)
0.6 (2.2)
0.8 (2.2)
Fluid Flow in gpm (lpm)
Fluid Flow in gpm (lpm)

14:1 (E) Check-Mate Pumps
14:1 (J) Check-Mate Pumps
Fluid Pressure in psig (MPa, bar)
160 (4.5)
Fluid Pressure in psig (MPa, bar)
160 (4.5)
(11.2, 112)
Air Flow in SCFM (m3/min)
(11.2, 112)
Air Flow in SCFM (m3/min)
120 (3.4)
120 (3.4)
(8.4, 84)
(8.4, 84)
80 (2.2)
80 (2.2)
(5.6, 56)
(5.6, 56)
40 (1.1)
40 (1.1)
(2.8, 28)
(2.8, 28)
0 2.6 3.9 1.3 (6.4) (9.8) (14.8)
6.5 (24.6) 5.2 (19.7)
7.8 (29.5)
0 2.6 3.9 1.3 (6.4) (9.8) (14.8)
6.5 (24.6) 5.2 (19.7)
7.8 (29.5)
Fluid Flow in gpm (lpm)
Fluid Flow in gpm (lpm)
20:1 (E) Check-Mate Pumps
35 (0.1)
Fluid Pressure in psig (MPa, bar)
Air Flow in SCFM (m3/min)
B
1500 (10.5, 105)
21 (0.6)
500 (3.5, 35)
7 (0.2)
0.2 (0.8)
0.4 (1.5)
0.6 (2.2)
0.8 (2.2)
Fluid Flow in gpm (lpm)
23:1 (E) Check-Mate Pumps
23:1 (J) Check-Mate Pumps
Fluid Pressure in psig (MPa, bar)
100 (2.8)
Fluid Pressure in psig (MPa, bar)
100 (2.8)
(17.5, 175)
Air Flow in SCFM (m3/min)
(17.5, 175)
Air Flow in SCFM (m3/min)
A
A
B
60 (1.7)
60 (1.7)
(10.5, 105)
(10.5, 105)
B
B
20 (0.6)
20 (0.6)
(3.5, 35)
(3.5, 35)
0 1.5 0.5 (1.9) (5.7)
2.5 (9.5)
3.2 (12.1)
0 1.5 0.5 (1.9) (5.7)
2.5 (9.5)
3.0 (11.4)
3.0 (11.4)
Fluid Flow in gpm (lpm)
Fluid Flow in gpm (lpm)

26:1 (J) Check-Mate Pumps
26:1 (E) Check-Mate Pumps
3000 (21.0, 210)
240 (6.7)
3000 (21.0, 210)
240 (6.7)
Fluid Pressure in psig (MPa, bar)
Fluid Pressure in psig (MPa, bar)
Air Flow in SCFM (m3/min)
Air Flow in SCFM (m3/min)
160 (4.5)
160 (4.5)
(14.0, 140)
(14.0, 140)
B
B
B
80 (2.2)
80 (2.2)
(7.0, 70)
(7.0, 70)
0 2.6 3.9 1.3 (6.4) (9.8) (14.8)
7.8 (29.5) 6.5 (24.6) 5.2 (19.7)
0 2.6 3.9 1.3 (6.4) (9.8) (14.8)
7.8 (29.5) 6.5 (24.6) 5.2 (19.7)
Fluid Flow in gpm (lpm)
Fluid Flow in gpm (lpm)
29:1 (E) Check-Mate Pumps
29:1 (J) Check-Mate Pumps
Fluid Pressure in psig (MPa, bar)
180 (5.0)
3000 (21.0, 210)
240 (6.7)
(21.0, 210)
Air Flow in SCFM (m3/min)
Fluid Pressure in psig (MPa, bar)
Air Flow in SCFM (m3/min)
A
B
120 (3.4)
160 (4.5)
(14.0, 140)
(14.0, 140)
60 (2.2)
80 (2.2)
(7.0, 70)
(7.0, 70)
2.0 3.0 1.0 (3.8) (7.6) (11.4)
4.0 (15.2)
0 2.0 1.0 (3.8) (7.6)
4.0 (15.2) 3.0 (11.4)
Fluid Flow in gpm (lpm)
Fluid Flow in gpm (lpm)
36:1 (E) Check-Mate Pumps
36:1 (J) Check-Mate Pumps
Fluid Pressure in psig (MPa, bar)
160 (4.5)
400 (11.2)
Fluid Pressure in psig (MPa, bar)
(28.0, 280)
(28.0, 280)
Air Flow in SCFM (m3/min)
Air Flow in SCFM (m3/min)
A A
300 (8.4)
120 (3.4)
(21.0, 210)
(21.0, 210)
B
B
80 (2.2)
200 (5.6)
(14.0, 140)
(14.0, 140)
B
100 (2.8)
40 (1.1)
(7.0, 70)
(7.0, 70)
0 1.6 0.8 (3.1) (6.1)
3.2 (12.1)
0 0.8 (3.1)
1.6 (6.1)
2.4 (9.1)
3.2 (12.1)
2.4 (9.1)
Fluid Flow in gpm (lpm)
Fluid Flow in gpm (lpm)

38:1 (E) Check-Mate Pumps
4500 (31.5, 315)
60 (12.5)
Air Flow in SCFM (m3/min)
47 (1.3)
(24.5, 245)
2500 (17.5, 175)
34 (0.6)
B
1500 (10.5, 150)
20 (0.6)
500 (3.5, 35)
7 (0.2)
0.2 (0.8)
0.4 (1.5)
0.6 (2.2)
0.8 (2.2)
Fluid Flow in gpm (lpm)
39:1 (G) Check-Mate Pumps
32 40 0 24 16 8
Fluid Pressure in psig (MPa, bar)
400 (11.2)
(28.0, 280)
Air Flow in SCFM (m3/min)
300 (8.4)
(21.0, 210)
200 (5.6)
(14.0, 140)
A
100 (2.8)
(7.0, 70)
0 2.0 1.0 (3.8) (7.6)
3.0 (11.4)
4.0 (15.2)
5.0 (19.0)
Fluid Flow in gpm (lpm)
40:1 (E) Check-Mate Pumps
40:1 (J) Check-Mate Pumps
Fluid Pressure in psig (MPa, bar)
90 (2.5)
Fluid Pressure in psig (MPa, bar)
90 (2.5)
(31.5, 315)
(31.5, 315)
Air Flow in SCFM (m3/min)
Air Flow in SCFM (m3/min)
70 (2.0)
70 (2.0)
(24.5, 245)
(24.5, 245)
A
50 (1.4)
50 (1.4)
(17.5, 175)
(17.5, 175)
30 (0.8)
30 (0.8)
(10.5, 150)
(10.5, 150)
500 (3.5, 35)
10 (0.3)
500 (3.5, 35)
10 (0.3)
0 0.8 1.2 0.4 (1.5) (3.1) (4.5)
1.6 (6.1)
0 0.8 1.2 0.4 (1.5) (3.1) (4.5)
1.6 (6.1)
(6.1)
Fluid Flow in gpm (lpm)
Fluid Flow in gpm (lpm)

55:1 (E) Check-Mate Pumps
55:1 (J) Check-Mate Pumps
Fluid Pressure in psig (MPa, bar)
Fluid Pressure in psig (MPa, bar)
240 (6.7)
240 (6.7)
(42.0, 420)
Air Flow in SCFM (m3/min)
(42.0, 420)
A A
160 (4.5)
160 (4.5)
(28.0, 280)
(28.0, 280)
B
B
80 (2.2)
80 (2.2)
(14.0, 140)
(14.0, 140)
0 2.0 3.0 1.0 (3.8) (7.6) (11.4)
4.0 (15.2)
0 2.0 3.0 1.0 (3.8) (7.6) (11.4)
4.0 (15.2)
Fluid Flow in gpm (lpm)
Fluid Flow in gpm (lpm)
61:1 (E) Check-Mate Pumps
64 (2.5)
7000 (49.0, 1490)
Air Flow in SCFM (m3/min)
64 (1.8)
(35.0, 350)
B
38 (1.1)
(21.0, 210)
13 (0.4)
1000 (7.0, 70)
0.2 (0.8)
0.4 (1.5)
0.6 (2.2)
0.8 (2.2)
Fluid Flow in gpm (lpm)
63:1 (E) Check-Mate Pumps
63:1 (J) Check-Mate Pumps
Fluid Pressure in psig (MPa, bar)
175 (4.9)
Fluid Pressure in psig (MPa, bar)
175 (4.9)
(49.0, 1490)
Air Flow in SCFM (m3/min)
(49.0, 1490)
Air Flow in SCFM (m3/min)
125 (3.5)
125 (3.5)
(35.0, 350)
(35.0, 350)
B
B
75 (2.1)
75 (2.1)
(21.0, 210)
(21.0, 210)
25 (0.7)
25 (0.7)
(7.0, 70)
(7.0, 70)
0 0.8 1.2 0.4 (1.5) (3.1) (4.5)
1.6 (6.1)
0 0.8 1.2 0.4 (1.5) (3.1) (4.5)
1.6 (6.1)
Fluid Flow in gpm (lpm)
Fluid Flow in gpm (lpm)

68:1 (E) Check-Mate Pumps
68:1 (J) Check-Mate Pumps
Fluid Pressure in psig (MPa, bar)
240 (6.7)
Fluid Pressure in psig (MPa, bar)
240 (6.7)
(56.0, 560)
Air Flow in SCFM (m3/min)
(56.0, 560)
Air Flow in SCFM (m3/min)
D D
180 (5.0)
180 (5.0)
(42.0, 420)
(42.0, 420)
B
B
120 (3.4)
120 (3.4)
(28.0, 280)
(28.0, 280)
60 (1.7)
60 (1.7)
(14.0, 140)
(14.0, 140)
0 1.6 0.8 (3.1) (6.1)
3.2 (12.1)
0 1.6 0.8 (3.1)
2.4 (9.1)
3.2 (12.1)
2.4 (9.1)
Fluid Flow in gpm (lpm)
Fluid Flow in gpm (lpm)
82:1 (E) Check-Mate Pumps
82:1 (H) Check-Mate Pumps
51 34 18 60 67 0 51 34 18 60
Fluid Pressure in psig (MPa, bar)
6000 (42.0, 420)
300 (8.4)
6000 (42.0, 420)
300 (8.4)
Fluid Pressure in psig (MPa, bar)
Air Flow in SCFM (m3/min)
Air Flow in SCFM (m3/min)
B
200 (5.6)
200 (5.6)
(28.0, 280)
(28.0, 280)
B
100 (2.8)
100 (2.8)
(14.0, 140)
(14.0, 140)
4.0 (15.2) 0 2.0 3.0 1.0 (3.8) (7.6) (11.4)
0 2.0 3.0 1.0 (3.8) (7.6) (11.4)
4.0 (15.2)
Fluid Flow in gpm (lpm)
Fluid Flow in gpm (lpm)

Performance Charts

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents
2ULJLQDOLQVWUXFWLRQV This manual contains English. MM 312376
Copyright 2007, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
www.graco.com Revision L, March 2014
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Pump fails to operate. | Restricted line or inadequate air sup- ply; closed or clogged valves. | Clear; increase air supply. Ensure that all valves are open. | p.16 |
| Pump fails to operate. | Obstructed fluid hose or gun/valve; fluid hose ID is too small. | Open, clear*; use a hose with a larger ID. | p.16 |
| Pump fails to operate. | Fluid dried on displacement rod. | Clean. Always stop pump at bottom of stroke. Keep enclosed wet cup 1/3 filled with a compatible solvent. | p.16 |
| Pump fails to operate. | Dirty, worn, or damaged motor parts. | Clean or repair; see separate motor man- ual. | p.16 |
| Pump fails to operate. | Runaway occurred. | See runaway section of Supply Units Oper- ation manual 313526. | p.16 |
| Pump operates but output is low on both strokes. | Restricted line or inadequate air sup- ply; closed or clogged valves. | Clear; increase air supply. Ensure all valves are open. | p.16 |
| Pump operates but output is low on both strokes. | Increase air pressure to ram for better load- ing. | p.16 | |
| Pump operates but output is low on both strokes. | Obstructed fluid hose or gun/valve; fluid hose ID is too small. | Open, clear*; use a hose with a larger ID. | p.16 |
| Pump operates but output is low on both strokes. | Bleed-type air valve is partially open. | Close bleed-type air valve. | p.16 |
| Pump operates but output is low on both strokes. | Air is leaking into supply container. | Check ram plate seal. | p.16 |
| Pump operates but output is low on both strokes. | Fluid is too heavy for pump priming. | Use drain/purge valve. Use a ram. See Supply Units Operation manual 313526. | p.16 |
| Pump operates but output is low on both strokes. | Held open or worn intake valve or seals. | Clear valve; replace seals. See separate Check-Mate Displacement Pump manual 312375. | p.16 |
| Pump operates but output is low on both strokes. | Worn packings in displacement pump. | Replace packings. See separate Check-Mate Displacement Pump manual 312375. | p.16 |
| Pump operates, but output is low on downstroke. | Fluid is too heavy for pump priming. | Use drain/purge valve. Use a ram. See Supply Units Operation manual 313526. | p.16 |
| Pump operates, but output is low on downstroke. | Held open or worn intake valve or seals. | Clear valve. Replace seals. See separate Check-Mate Displacement Pump manual 312375. | p.16 |
| Pump operates, but output is low on upstroke. | Held open or worn intake valve or seals. | Clear valve. Replace seals. See separate Check-Mate Displacement Pump manual 312375. | p.16 |
| Erratic or accelerated pump speed. | Exhausted fluid supply. | Refill and prime. | p.17 |
| Erratic or accelerated pump speed. | Fluid is too heavy for pump priming. | Use drain/purge valve. Use a ram. See Supply Units Operation manual 313526. | p.17 |
| Erratic or accelerated pump speed. | Increase ram air pressure. | p.17 | |
| Erratic or accelerated pump speed. | Held open or worn intake valve or seals. | Clear valve. Replace seals. See separate Check-Mate Displacement Pump manual 312375. | p.17 |
| Erratic or accelerated pump speed. | Held open or worn priming piston. | Clear; service. See separate Check-Mate Displacement Pump manual 312375. | p.17 |
| Erratic or accelerated pump speed. | Worn packings in displacement pump. | Replace packings.See separate Check-Mate Displacement Pump manual 312375. | p.17 |
Owners and our team usually reply within a day — and your question helps the next person too.