GTP10 Herbicide Pump

For pumping herbicides. Do not use to pump other fluids including water.
Model 260410, 10 gpm (38 lpm), 12 VDC (CSA C/US listed motor) Model 260411, 10 gpm (38 lpm), 12 VDC (CSA C/US listed motor)
Includes 8 ft (2.44 m) hose, nozzle and inlet suction tube Model 260408, 12 gpm (45 lpm), 115 VAC Model 260409, 12 gpm (45 lpm), 115 VAC
10 psi (0.07 MPa, 0.7 bar) Maximum Working Pressure

CSA mark applies only to 12 VDC motors for Class I, Div I, Group D Hazardous Locations.
Graco Inc. P.O. Box 1441 Minneapolis, MN 55440-1441 Copyright 2005, Graco Inc. is registered to I.S. EN ISO 9001

The following general warnings are for the setup, use, grounding, maintenance, and repair of this equipment. Addi- tional, more specific warnings may be found throughout the body of this manual where applicable. Symbols appear- ing in the body of the manual refer to these general warnings. When these symbols appear throughout the manual, refer back to these pages for a description of the specific hazard.

BURN HAZARD Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe burns, do not touch hot fluid or equipment. Wait until equipment/fluid has cooled completely.

suction tube assembly (5c) and screw the suction tube into the pump inlet (1j).
When unpacking pump, check for shipping damage. Report any shipping damage to delivering carrier imme- diately.


To install wiring for a negative ground system:
Power cable can be cut to shorter length if 18 feet (5.5 m) is not required. Cut to proper length and proceed with steps 3 and 4.
For tanks deeper than 36 in. (914 mm) you will need a standard 1 in. (25 mm) pipe with 1 in. npt threads on one end. Suction tubes longer than 60 in. (1.52 m) require a foot valve (Graco Part No. 260217) at the bottom of the tube to prevent loss of prime.
Installation

On 115 VAC pumps, electrical connections must be made by a licensed electrician per requirements of local, state, and national codes regarding class 1, group D installations. Only rigid conduit with threaded connections should be used. Conduit opening in pump must be sealed with waterproof, herbicide-resistant sealant. Failure to comply with this warning could result in injury from electrical shock.
Installation

Maintenance
Before servicing, turn pump off and open the nozzle to relieve pressure.
Do not operate pump dry. Do not run pump for more than 5 minutes with nozzle closed. Do not operate pump for more than 30 minutes continuously in 1 hour.
On/Off switch lever (8d) is located under nozzle holder. Remove nozzle before turning pump on.
Proper flushing of pump after use with herbicides and chemicals is essential for long service life. Many herbi- cides dry quickly and will make pump inoperative if allowed to dry inside pump.
Operation

Maintenance

Troubleshooting

Troubleshooting


Parts Drawing · 260452 253719

Ref. No. Description Qty. 1 260458 KIT, pump with swivel, blue (includes items 1a-1k) 253723 KIT, pump with swivel, black (includes items 1a-1k) 1a BODY, assembly 1 1b COVER, gear 1 1c (10a) GEAR 2 1d SHAFT, gear 2 1e FITTING, outlet, 3/4 in. npt, street elbow (not shown)
Ref. No. Description Qty.
5 260300 KIT, suction, pipe; includes items 5a-5d (Models 260411, 260409 only) 5a PIPE, PVC 2 5b COUPLER, PVC, female 1 5c ADAPTER, PVC, male 1 5d CEMENT, PVC (not shown) 1 6* 260454 KIT, cable, 12 V (includes items 6a-6c) 6a CLAMP, battery 2 BLACK SLEEVE 1 RED SLEEVE 1 6b STRAIN RELIEF 1 6c ASSEMBLY, power cable, 18 ft (5.5 m), fuse holder, 20 amp fuse
1f (10c) SEAL, gear cover 1 1g (10b) KEY, drive 1 1h SEAL, shaft 1 1i BOLT, hex, 5/16-18 x 3/4 in. 4 1j FITTING, inlet 1 1k NUT, union 1 2 260450 KIT, motor, 12 VDC, blue (includes items 2a-2i) 260452 KIT, motor, 115 VAC, blue (includes items 2a-2i) 253719 KIT, motor, 12 VDC, black (includes items 2a-2i) 253721 KIT, motor, 115 VAC, black (includes items 2a-2i) 2a COVER, electrical 1 2b HOUSING, electrical, 12 V 1 2c BOLT, hex, 1/4-20 x 3/4 in. 10 2d NUT, 10-32 2 2e WIRE NUT, 260450 2 WIRE NUT, 260452 3 2f FLAG TERMINAL 2 2g MOTOR, electric 1 2h COVER, nozzle 1 2i GUIDE, nozzle 1 3 260456 KIT, filter, universal (includes items 3a-3d) 3a COVER, strainer 1 3b SCREEN 1 3c SCREW, hex head, 10-24 x 3/8 in. 4 3d SEAL, strainer cover 1 4 260544 KIT, popoff (includes items 4a-4d) 4a POPPET, relief valve 1 4b SPRING, relief valve 1 4c SEAL, relief valve 1 4d RING, retaining 1
7 260084 GASKET, inlet 1 8 260433 KIT, switch, blue (includes items 8a-8g) 253718 KIT, switch, black (includes items 8a-8g) 8a COVER, switch 1 8b BRACKET, switch 1 8c CAM, actuator switch 1 8d SWITCH, actuator assy. 1 8e SWITCH 1 8f SCREW, phillips, 8-32 x 3/8 in. 2 8g SCREW, phillips, 6-32 x 1/4 in. 1 9 260061 ADAPTER, bung 1 10 260277 KIT, gear (includes 10a-10c) 10a (1c) GEAR 2 10b (1g) KEY, drive 1 10c (1f) SEAL, gear, cover 1 11 260310 HOSE, 8 ft, 3/4 in. (MBE), (Models 260411, 260409 only) (not shown) 12 260079 NOZZLE, 3/4 npt (f), (Models 260411, 260409 only) (not shown) 13▲15G901 LABEL, warning (not shown)
▲Replacement Danger and Warning labels, tags, and
cards are available at no cost.
* Used on 12 VDC models only
Parts List

Working pressure 10 psi (0.07 MPa, 0.7 bar) Inlet size 1 in. npt Outlet size 3/4 in. npt Weight 20 lb (9 kg) Power cable 18 ft (5.5 m), 14 AWG (12 VDC models only) Current draw 12 VDC models: 12.5 amps
115 VAC models: 2 amps Duty cycle 30 min/hour Suction tube 1 in. x 34 in. (25.4 mm x 864 mm) Wetted parts carbon steel with zinc plating, 416 and 302 stainless
steel, fluoroelastomer, Buna-N, Aluminum, Valox®, Nylon, Nitrile, PVC, Vellumoid, PTFE, EPDM
Valox® is a registered trademark of the General Electric Company
!
GPMLPM
0!24.5-"%23 ,%'%.$ ! 6$#

Technical Data

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6928 or Toll Free: 1-800-533-9655, Fax: 612-378-3590
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
This manual contains English. MM 311628 Graco Headquarters: Minneapolis International Offices: Belgium, China, Japan, Korea
www.graco.com 311628 10/2006 Revised 9/2009
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Motor runs but pump will not prime. | Motor rotation wrong. (12 VDC units only.) | Check wiring instructions for possible problems. | p.8 |
| Motor runs but pump will not prime. | Missing relief valve o-ring seal (4c). | Remove gear cover (1b) inspect seal (4c), replace if missing or damaged. | p.8 |
| Motor runs but pump will not prime. | Sheared drive key (1g). | Remove cover (1b) and inspect key (1g/10b), replace if worn or sheared. | p.8 |
| Motor runs but pump will not prime. | Dirt under relief poppet (4a) or seal (4c). | Remove cover (1b) and inspect, clean or replace if damaged. | p.8 |
| Motor runs but pump will not prime. | Strainer seal (3d) leaking. | Inspect and replace if damaged. | p.8 |
| Motor runs but pump will not prime. | Suction height too high to prime. | See Priming Pump, page 5. | p.8 |
| Motor runs but pump will not prime. | Worn or damaged gears. | Remove cover (1b) and inspect gears. Replace if worn or damaged. | p.8 |
| Motor runs but pump will not prime. | Fluid level low. | Refill tank. | p.8 |
| Motor runs but pump will not prime. | Cover seal (1f/10c) damaged. | Replace if worn or damaged. | p.8 |
| Motor runs but pump will not prime. | Inlet strainer (3b) clogged. | Remove and clean or replace. | p.8 |
| Motor runs but pump will not prime. | Air leak in suction tube. | Inspect all joints in suction tube, make sure all joints have sealant applied. | p.8 |
| Motor runs but pump will not prime. | Air lock in system. | This may occur if filter or meter or automatic shut-off nozzle is used. If this occurs, fill pump and meter with herbicide through top of pump. | p.8 |
| Motor runs but pump will not prime. | Motor does not run at proper speed. | Check electric connections. Check supply voltage for proper voltage level. | p.8 |
| Unit pumps but output flow is low. | Clogged inlet strainer (3b). | Clean or replace. | p.8 |
| Unit pumps but output flow is low. | Air leak in suction tube. | Check to make sure all joints in suc- tion tube are sealed. | p.8 |
| Unit pumps but output flow is low. | Suction tube too close to tank bottom. | Suction tube must have a 2 in. (51 mm) minimum clearance. | p.8 |
| Unit pumps but output flow is low. | Tank empty. | Refill tank. | p.8 |
| Unit pumps but output flow is low. | Tank not vented. | Tank must be vented to atmosphere. | p.8 |
| Unit pumps but output flow is low. | Worn or damaged gears. | Remove cover (1b) and inspect gears. Replace if worn or damaged. | p.8 |
| Unit pumps but output flow is low. | Damaged motor. | Replace motor. | p.8 |
| Unit pumps but output flow is low. | Clogged suction tube, hose, or nozzle. | Inspect and clean. | p.8 |
| Motor stalls when nozzle is closed. | Bypass relief valve (4a) stuck. | Inspect relief valve, making sure poppet is free. Replace if damaged. | p.8 |
| Motor stalls when nozzle is closed. | Low supply voltage. | Check supply voltage. | p.8 |
| Motor stalls when nozzle is closed. | Gears (1c/10a) damaged and binding. | Inspect gears. Gears should turn freely. Replace if damaged. | p.8 |
| Motor stalls when nozzle is closed. | Faulty motor. | Replace motor. | p.8 |
| Herbicide leaking in motor mount. | Faulty or damaged motor shaft seal (1h). | Replace shaft seal | p.9 |
| Herbicide leaking in motor mount. | Operating pump extended time with nozzle closed. | Do not exceed 5 minutes of operation with nozzle closed. | p.9 |
| Herbicide leaking in motor mount. | Motor shaft worn. | Replace motor if shaft has groove worn in seal area. | p.9 |
| Motor overheating. | Gears (1c/10a) binding. | Check to make sure gears turn freely on shaft. | p.9 |
| Motor overheating. | Operating pump extended time with nozzle closed. | Do not exceed 5 minutes of operation with nozzle closed. | p.9 |
| Motor overheating. | Clogged inlet strainer (3b). | Clean or replace, see Maintenance, page 6. | p.9 |
| Motor overheating. | Clogged suction tube, hose, or nozzle. | Inspect and clean if required. | p.9 |
| Motor overheating. | Operating pump more than 30 min- utes continuous duty. | Limit operation to 30 minutes per hour. | p.9 |
| Switch will not turn pump on. | Blown fuse. | Replace fuse. 20 amp automotive fuse (Littelfuse ATO 257020 or Bussman ATC-20). | p.9 |
| Switch will not turn pump on. | Electrical problem. | Check that supply voltage is proper and getting to pump. | p.9 |
| Switch will not turn pump on. | Defective switch (8e). | Check and replace if defective. | p.9 |
| Switch will not turn pump on. | Mechanical problem. | Check switch actuator cam (8c). Cam should be actuating the switch (8e). | p.9 |
| Switch will not turn pump on. | Damaged or defective motor. | Check motor, replace if damaged or defective. | p.9 |
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.