® A-25
P L U R A L C O M P O N E N T P R O P O R T I O N E R
For spraying or dispensing 1:1 ratio polyurethane foam formulations and other 1:1 fast setting materials.
Not for use in explosive atmospheres or hazardous locations.
This model is field-configurable to the following supply voltages: 230 V, 1 Phase 230 V, 3 Phase 380 V, 3 Phase
2000 psi (14 MPa, 138 bar) Maximum Fluid Working Pressure 80 psi (550 kPa, 5.5 bar) Maximum Air Working Pressure
See page 9 for model information, including maximum working pressure and approvals.


All proportioners can be configured to operate on 380V (4 wire), 230V (3 wire), or 230V 1Ø.
All systems include a proportioner, spray gun, and 60 ft (18.3 m) of heated hose.
Manuals are available at www.graco.com
Component manuals in English:
Proportioner Models

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
ELECTRIC SHOCK HAZARD This equipment must be grounded. Improper grounding, setup, or usage of the system can cause electric shock.
TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed.
PERSONAL PROTECTIVE EQUIPMENT You must wear appropriate protective equipment when operating, servicing, or when in the operating area of the equipment to help protect you from serious injury, including eye injury, hearing loss, inhalation of toxic fumes, and burns. This equipment includes but is not limited to:
BURN HAZARD Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe burns:

FIRE AND EXPLOSION HAZARD Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:
SKIN INJECTION HAZARD High-pressure fluid from gun, hose leaks, or ruptured components will pierce skin. This may look like just a cut, but it is a serious injury that can result in amputation. Get immediate surgical treatment.

EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury.
PRESSURIZED ALUMINUM PARTS HAZARD Use of fluids that are incompatible with aluminum in pressurized equipment can cause serious chemical reaction and equipment rupture. Failure to follow this warning can result in death, serious injury, or property damage.
THERMAL EXPANSION HAZARD Fluids subjected to heat in confined spaces, including hoses, can create a rapid rise in pressure due to the thermal expansion. Over-pressurization can result in equipment rupture and serious injury.
MOVING PARTS HAZARD Moving parts can pinch, cut or amputate fingers and other body parts.

Isocyanate Conditions
Moisture Sensitivity of Isocyanates
Isocyanates (ISO) are catalysts used in two component foam and polyurea coatings. ISO will react with moisture (such as humidity) to form small, hard, abrasive crystals, which become suspended in the fluid. Eventually a film will form on the surface and the ISO will begin to gel, increasing in viscosity. If used, this partially cured ISO will reduce performance and the life of all wetted parts.
Spraying or dispensing materials containing isocyanates creates potentially harmful mists, vapors, and atomized particulates.
Read material manufacturer’s warnings and material MSDS to know specific hazards and precautions related to isocyanates.
Prevent inhalation of isocyanate mists, vapors, and atomized particulates by providing sufficient ventilation in the work area. If sufficient ventilation is not available, a supplied-air respirator is required for everyone in the work area.
To prevent exposing ISO to moisture:
To prevent contact with isocyanates, appropriate personal protective equipment, including chemically impermeable gloves, boots, aprons, and goggles, is also required for everyone in the work area.
Some materials may become self-igniting if applied too thickly. Read material manufacturer’s warnings and material MSDS.
Foam Resins with 245 fa Blowing Agents
Some foam blowing agents will froth at temperatures above 90°F (33°C) when not under pressure, especially if agitated. To reduce frothing, minimize preheating in a circulation system.
Cross-contamination can result in cured material in fluid lines which could cause serious injury or damage equipment. To prevent cross-contamination of the equipment’s wetted parts, never interchange component A (isocyanate) and component B (resin) parts.

Changing the material types used in your equipment requires special attention to avoid equipment damage and downtime.

Typical Installation, without Circulation

* Shown exposed for clarity. Wrap with tape during operation.
Key for FIG. 1
A Reactor Proportioner B Heated Hose C Fluid Temperature Sensor (FTS) D Heated Whip Hose E Spray Gun F Proportioner and Gun Air Supply Hose G Feed Pump Air Supply Lines H Waste Containers J Fluid Supply Lines K Feed Pumps L Agitator (if required)
M Desiccant Dryer N Bleed Lines/Over Pressure Relief P Gun Fluid Manifold

Typical Installation, with Circulation
Key for FIG. 2
A Reactor Proportioner B Heated Hose C Fluid Temperature Sensor (FTS) D Heated Whip Hose E Spray Gun F Proportioner and Gun Air Supply Hose
G Feed Pump Air Supply Lines J Fluid Supply Lines K Feed Pumps L Agitator (if required) M Desiccant Dryer N Recirculation/Over Pressure Relief Return Hoses P Gun Fluid Manifold

* Shown exposed for clarity. Wrap with tape during operation.


AB
U
Component Identification

Key:
R Main Disconnect Switch - Controls power to heating circuits. I
AH *Primary Heater Over-Temperature Switches -
Sends signal to temperature controller if heater exceeds maximum temperature condition.
S Main Air Filter - Filters system air supply.
AI Resin (B) Pump Wet Cup - Access for daily wet cup refill.
T Resin (B) Pressure Gauge - Displays pressure in resin proportioning system (B side).
DD Main Air Inlet Ball Valve - (1/2 NPT female fitting)
U Resin (B) - Inlet Supply Valve
FF ISO (A) Inlet - Fitting (3/4 swivel fitting)
GG Resin (B) Inlet - Fitting (3/4 swivel fitting)
V Resin (B) Fluid Y-Strainer - (20 mesh)
W ISO (A) Pressure Gauge - Displays pressure in isocyanate proportioning system (A side).
X ISO (A) - Inlet Supply Valve
Y ISO (A) Fluid Y-Strainer - (20 mesh)
Z ISO (A) Pump Lube System - Behind Proportioner shroud. (A side only)
AA ISO (A) - Packing Nut and Lube Cup - (A side
AB *Primary Heater Thermocouples - Senses
temperature of primary heater and inputs that information.
AC FTS Jumper Harness - Carries electrical signal
from FTS sensor in isocyanate hose to hose temperature controller.
AD Primary Heaters - Heats material to required
dispensing temperature.
AE ISO (A) - (Isocyanate) Proportioning Pump -
Draws in and dispenses a fixed volume of isocyanate to gun.
AF Resin (B) Proportioning Pump - Draws in and
dispenses a fixed volume of resin to gun.
AG Power-Lock™ Hose Heat Connection - Connects
power to heated hoses.
Component Identification · only)


DataTrak (optional) See page 32. See Tempera- ture Controls and Indicators
E L EC T RO N IC M O N I T O R IN G S Y S T E M
Air Motor Pressure Gauge
Air Motor Shutoff Valve

To prevent damage to the softkey buttons, do not press the buttons with sharp objects such as pens, plastic cards, or fingernails.

Zone A Arrow Keys
Heater A On/Off Key
Zone B Arrow Keys
Heater B On/Off Key
Hose Zone Arrow Keys
Hose Heater On/Off Key

Temperature Displays
Located on right side of unit, page 11. Turns heater
Show actual temperature or target temperature of heater zones, depending on selected mode. Defaults to actual at startup. Range is 32-190°F (0-88°C) for A and B, 32-180°F (0-82°C) for hose.
power ON and OFF . Does not turn
heater zones or pumps on.
Actual Temperature Key/LED
Press to display actual temperature.
Located inside Reactor cabinet.
Press and hold to display electrical current.

Press to display target temperature.
Press and hold to display heater control circuit

board temperature.
Press or to change temperature scale.
Heater Zone On/Off Keys/LEDs
Press to turn heater zones on and off. Also clears
heater zone diagnostic codes, see page 35.
Press , then press or to adjust tem-
perature settings in 1 degree increments.
Component Identification

Locate Reactor A-25
Electrical Requirements
Improper wiring may cause electric shock or other serious injury if work is not performed properly.
Reactor A-25 can be wired to 3 types of power source:
Setup

230V, 1 Phase: Use a screwdriver to connect two power leads to the top two middle terminal positions as shown. Connect green to ground (GND). See page 17 for proper jumper positions.
230V, 3 Phase Delta: Use a screwdriver to connect three power leads to top three left terminals as shown. Connect green to ground (GND). See page 17 for proper jumper positions.
a. Feed power cord through strain relief (SR) on right side of unit. Push black die release lever (RL) down to release contacts block (PD) for easy wiring.
b. Connect power leads to Power Disconnect Switch (PD). Snap contacts block (PD) back onto switch.
c. Tighten strain relief nut.
380V, 3 Phase WYE: Use a screwdriver to connect four power leads to the top terminals as shown. Connect neutral only to N. Connect green to ground (GND). See page 17 for proper jumper positions.
d. Connect ground wire to ground lug (GL).

GL
Setup

Find location for power jumpers which are in a plastic bag tie wrapped to the ground lug.
ti17569a Heater Jumpers Install Power Jumpers
TB2
Terminal Blocks Install red jumpers
Step Three - Reposition Heater Jumpers (if necessary)
Find location of Heater Jumpers.
Machines are shipped with heaters wired for 6000 watts. To reposition heater jumpers for 3000 watts, change jumper positions as shown below.
TB2
Terminal Blocks Position red jumpers
Setup · Power Jumper Location

Fluid Supply Connections

Feed pumps are typically used. Siphon feeding is not recommended. Connect material supply to inlets of proportioning unit as follows:
The equipment must be grounded to reduce the risk of static sparking and electric shock. Electric or static sparking can cause fumes to ignite or explode. Improper grounding can cause electric shock. Grounding provides an escape wire for the electric current.

Connect main air supply (F) to air inlet 1/2 in. npt (f) valve (DD) at air filter (S). Hose fitting requires a 1/2 NPT male fitting.

Prepare isocyanate pump lubrication system as follows:
The lubrication system is now ready for operation; no priming is required.
Setup

Connect Heated Hose


Do not install shutoffs downstream of the PRESSURE RELIEF/SPRAY valve outlets (BA, BB). The valves function as over pressure relief valves when set to SPRAY. Lines must be open so valves can automatically relieve pressure when machine is operating.
The fluid temperature sensor (FTS) and whip hose must be used with heated hose; see page 19. Hose length, including whip hose, must be 60 ft (18.3 m) min- imum.
If circulating fluid back to the supply drums, use high pressure hose rated to withstand the maximum working pressure of this equipment.
If Recirculating to Supply Drum: Connect high pressure hose (R) to relief fittings (BA, BB) of both PRESSURE RELIEF/SPRAY valves. Route hose back to component A and B drums. Refer to manual 309852.

Alternate recirculation hoses (requires adapter fittings):
249508 - ISO (A) (moisture guard) red hose, 1/4 in. (6 mm) ID; #5 JIC fittings (m x f); 35 ft (10.7 m) long.
249509 - Resin (B) blue hose; 1/4 in. (6 mm) ID, #6 JIC fittings (m x f), 35 ft (10.7 m) long.

BB
Install FTS between main hose and whip hose. See Heated Hose manual for instructions.
Setup

For Probler P2 guns: Connect hoses to inlet valves.

For Fusion guns: Connect hoses to inlet manifold. Do not connect manifold to gun.


Fusion AP Gun shown.
Setup


a. For Probler P2 guns: Loosen hose fittings and bleed out air until air-free fluid comes from hoses.
Do not operate Reactor without all covers and shrouds in place.
b. For Fusion guns: Hold gun fluid manifold over two grounded waste containers. Open fluid valves A and B until clean, air-free fluid comes from valves. Close valves.

The Fusion AP Gun is shown.

See hose manual. Pressure check for leaks. If no leaks, wrap hose and electrical connections to protect from damage.

Always provide two grounded waste containers to keep component A and component B fluids separate.
Initial Startup

for each zone.
See Setup, page 15.
zone.
perature.
scale.


When in manual current control mode, monitor hose temperature with thermometer. Install per instructions below. Thermometer reading must not exceed 160°F (71°C). Never leave machine unattended when in manual current control mode.
or until display shows desired temper-
If FTS is disconnected or display shows diag- nostic code E04, turn main power switch OFF
then ON to clear diagnostic
startup, display will show hose current (0A). See step 9, page 22.
code and enter manual current control mode.
display will show current to hose. Current

is not limited by target temperature.
Do not turn on hose heat without fluid in hoses.
Press or to adjust current setting.
To prevent overheating, install hose thermome- ter close to gun end, within operator view. Insert thermometer through foam cover of A compo- nent hose so stem is next to inner tube. Ther- mometer reading will be about 20°F less than actual fluid temperature.
heat hose (15-60 min). Indicator will flash very slowly when fluid reaches target temperature. Dis- play shows actual fluid temperature in hose near FTS.

If thermometer reading exceeds 160°F (71°C),
reduce current with key.
Thermal expansion can cause over pressurization, resulting in equipment rupture and serious injury, including fluid injection. Do not pressurize system when preheating hoses.
Initial Startup

Pump rod and connecting rod move during operation. Moving parts can cause serious injury such as pinching or amputation. Keep hands and fingers away from wet-cup during operation. Close main air valve before filling wet-cup.
Z
Initial Startup


E L EC T RO N IC M O N I T O R IN G S Y S T E M
Spraying

Flow rate, atomization, and amount of overspray are affected by four variables.

GB


Spraying


Park the pumps at the end of the day to cycle propor- tioner pumps to home position, submerging displace- ment rod.

Shutdown
The Fusion AP gun is shown.
Park

Flush equipment only in a well-ventilated area. Do not spray flammable fluids. Do not turn on heaters while flushing with flammable solvents.
SB SA
N
Only use flush solvents that are compatible with Fluoroelastomer seals. Non-compatible solvents will damage seals and cause hazardous conditions, such as high pressure leaks.
Flushing

Daily Start-up Procedure

To prevent excessive pressure build-up in heated hoses, always bring hoses and primary heater up to operating temperature before opening air motor shutoff valve.


Uncoil heated hoses before turning on hose heater switch to prevent overheating and hot spots within hose.
Operation

The Fusion AP gun is shown.


Operation

Circulation Through Reactor

and heat zones by pressing .
Do not turn on heat zone unless hoses are
Do not circulate fluid containing a blowing agent without consulting with your material supplier regarding fluid temperature limits.
already loaded with fluid.
To circulate through gun manifold and preheat hose, see page 31.

and temperatures reach targets. Increase
the pressure once the temperatures are on target.
Do not install shutoffs downstream of the PRESSURE RELIEF/SPRAY valve outlets (BA, BB). The valves function as overpressure relief valves
when set to SPRAY . Lines must be open so valves can automatically relieve pressure when machine is operating.


Fluid Circulation

, , and heat zones by pressing
Do not circulate fluid containing a blowing agent without consulting with your material supplier regarding fluid temperature limits.
Circulating fluid through the gun manifold allows rapid preheating of hose.
and temperatures reach targets. Increase
the pressure once the temperatures are on target.

R CK
The Fusion AP gun manifold is shown.
Table 1: Circulation Kit (CK) Part Gun Manual 246362 Fusion AP 309818 256566 Fusion CS 313058 GC1703 Probler P2 313213
Fluid Circulation

DataTrak Controls and Indicators
The DataTrak on the Reactor A-25 sprayers do not have runaway protection. For setup and operation instructions see DataTrak Operation, page 33.
Key for FIG. 4
AB Combined Lower Displacement (user settable)
RK Reset Key (Resets faults. Press and hold for 3 seconds to
clear the batch totalizer.) Push to toggle between flow rate and cycle rate. CF Cycle/Flow Rate BT Batch Totalizer GT Grand Totalizer RT Runaway Toggle (leave disabled)
AC Flow Rate Units (user settable to gpm [US], gpm
[Imperial], oz/min [US], oz/min [Imperial], l/min, or cc/min) AD LED (fault indicator when lit) AE Display PF Prime/Flush Key (Enables Prime/Flush mode. While in
Prime/Flush mode, the batch totalizer [BT] will not count.) LED will flash while in Prime/Flush mode.
AE, see details at right


CF BT
AD
RT
AC

RK PF
FIG. 4. DataTrak Controls and Indicators

See FIG. 4, page 32. The last digit of the batch totalizer (BT) represents tenths of gallons or liters. To reset the totalizer, press any key to wake up the display, then
press and hold for 3 seconds.
Press to toggle between flow rate units and cycles. A letter under the BT display indicates that both BT and GT are displaying gallons (g) or liters (l). No letter means both BT and GT are displaying cycles.
disable runaway protection press to change the
value, then to save the value and move the cur- sor to the next data field.
See FIG. 4, page 32. The display (AE) will turn off after 1 minute of inactivity in Run mode or 3 minutes in Setup mode. Press any key to wake up the display.
then press once more to exit Setup mode.
See DataTrak Diagnostic Codes page 35.
. The Prime/Flush symbol will appear in the dis-
play and the LED will flash .
the display, then press . The Prime/Flush sym- bol will disappear from the display and the LED will stop flashing.
DataTrak Operation

Maintenance

Temperature Control Diagnostic Codes
Temperature control diagnostic codes appear on tem- perature display.
Code Code Name Alarm Zone
01 High fluid temperature Individual
These alarms turn off heat. E99 clears automatically when communication is regained. Codes E03 through
02 High zone current Individual
03 No zone current Individual
E06 can be cleared by pressing . For other codes,
04 FTS or thermocouple disconnected Individual
05 Control board over temperature Individual
06 Communication cable unplugged Individual
turn main power OFF then ON to clear.
30 Momentary loss of communication All
99 Loss of communication All
See repair manual for corrective action. NOTE: For hose zone only, if FTS is disconnected at startup, display will show hose current 0A.
DataTrak can diagnose several problems with the pump. When the monitor detects a problem, the LED (AD, FIG. 4) will flash and a diagnostic code will appear on the dis- play.
To acknowledge the diagnosis and return to the normal
operating screen, press once to wake up the display, and once more to clear the diagnostic code screen.
Symbol Code Code Name Diagnosis Cause
E-2 Diving Down Leak during downstroke. Worn intake valve.
E-3 Low Battery Battery voltage too low to stop runaway.
Low battery. Replace battery; see Reactor A-25 Repair manual.
E-6 Blown Fuse Fuse is blown. Replace fuse; see Reactor A-25 Repair manual.
Diagnostic Codes



Dimension in. (mm) in. (mm) A 43.5 (1105) 43.5 (1105) B 29 (736.6) 21.5 (546) C 30 (762) 24.5 (622)
Dimensions

Category Data Maximum Fluid Working Pressure 2000 psi (14 MPa, 138 bar) Maximum Air Supply Pressure 125 psi (0.9 MPa, 9 bar) Maximum Air Working Pressure 80 psi (550 kPa, 5.5 bar) Pressure Ratio 25:1 Air consumption with 02 tip at 1500 psi stall pres- sure
28 scfm (0.8m3/min)
Machine Maximum Power with hose 9000 Watts Voltage Requirement (50/60 Hz)
230 V, 1 Phase 230 V, 3 Phase (Delta) 380 V, 3 Phase (WYE 220 V to Neutral) Amperage Requirement (Full Load Peak)* 40 amps @ 230 V, 1 Phase 32 amps @ 230 V, 3 Phase 18.5 amps @ 380 V, 3 Phase Maximum Heater Fluid Temperature 190 °F (88 °C) Maximum Hose Fluid Temperature 180 °F (82 °C) Maximum Ambient Temperature 120 °F (49 °C) Maximum Output 25 lb/min. (11.4 kg/min.) Output Per Cycle (A and B) 0.025 gal/cycle (0.095 ltr/cycle) Heater Power 6000 Watts Hose Power 2790 Watts Sound Pressure (see NXT air motor manual) 70.2 dB(A) Sound Power (see NXT air motor manual) 80.1 dB(A) Viscosity Range 250-1500 centipoise (typical) Maximum Fluid Inlet Pressure 300 psi (2.1 MPa, 21 bar) or 15% of output pressure Fluid Inlet/Strainer Filter 20 mesh standard Air inlet Filter Mesh 40 Micron Component B (Resin) Inlet 3/4 npt(f) swivel Component A (Isocyanate) Inlet 3/4 npt(f) swivel Recirculation/Block Hose Connections Iso (A) side: #5 JIC (m); Resin (B) side: #6 JIC (m) Maximum Heated Hose Length*** 210 ft of 3/8 ID Weight 310 lb (140.6 kg) Wetted Parts Carbon steel, stainless steel, chrome, aluminum, Fluoroelastomer, PTFE, nylon
*Full load amps with all devices operating at maximum capabilities with 210 ft (64.1 m) of hose.
***210 ft (64 m) of heated hose will produce the maximum allowable heat capacity. 310 ft (94 m) of heated hose may be used, but will have 25% less heat capacity.
Technical Data

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents
Original instructions. This manual contains English. MM 3A1569
Copyright 2011, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.