Husky™15120 Air-Operated
Diaphragm Pump 3A2889A EN
Polypropylene or PVDF pumps for fluid transfer applications, including high viscosity materials. For professional use only. Not for use in European explosive atmosphere locations.

PROVEN QUALITY. LEADING TECHNOLOGY.


The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:
Static charge may build up on plastic parts during cleaning and could discharge and ignite flammable vapors. To help prevent fire and explosion:
Fluid from the equipment, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury.



Distributor Note
a. Use the 20–digit number from the ID plate on the pump. If you only have the Graco 6–digit part number, use the Online Husky Selector Tool to find the corresponding 20–digit number.
Please call your distributor.
b. Use the Configuration Number Matrix on the next page to understand which parts are described by each digit.
Use the Online Husky Selector Tool on the Process Equipment page at www.graco.com
c. Refer to the main Parts illustration and to the Parts/Kits Quick Reference. Follow the page references on these two pages for further ordering information, as needed.
Please call your distributor.
Ordering Information

Check the identification plate (ID) for the Configuration Number of your pump. Use the following matrix to define the components of your pump.


Graco Inc., P.O. Box 1441 Mpls, MN 55440 USA



Configuration Number Matrix


Troubleshooting

Troubleshooting


Follow the Pressure Relief Procedure whenever you see this symbol.


This equipment stays pressurized until pressure is relieved manually. To help prevent serious injury from pressurized fluid, such as splashing in the eyes or on skin, follow the Pressure Relief Procedure when you stop pumping and before you clean, check, or service the equipment.
Follow these instructions to install Air Valve Replacement Kit 24B773.
Repair

Follow these instructions to service the air valve with one of the available repair kits. Air Valve Seal Kit parts are marked with a †. Air Valve Repair Kit parts are marked with a ♦. Air Valve End Cap Kit parts are marked with a ‡.
Disassemble the Air Valve

Lips face down.
Lips face up.
Reassemble the Air Valve
Repair

7. Grease and install the detent assembly (203♦) into the piston. Install the o-ring (214♦) on the cup (213♦). Apply a light film of grease to the outside surface of the o-ring and the inside mating surface of the base (212♦). Orient the end of the base that has a magnet toward the end of the cup that has the larger cutout. Engage the opposite end of the parts. Leave the end with the magnet free. Tilt the base toward the cup and fully engage the parts, using care so that the o-ring remains in place. Install the spring (211♦) onto the protrusion on the cup. Align the magnet in the base with the air inlet and install the cup assembly.

Apply lithium- based grease.
U-cup lips must face piston.
Apply lithium- based grease to contact surface.
Air inlet.
Repair


Disassemble the Check Valve
Reassemble the Check Valve
Figure 1 Check valve assembly
Torque to 190 to 200 in-lb (21 to 25 N·m). Follow torque sequence. See Torque Instructions, page 19.
Arrow (A) must point toward outlet manifold
The chamfered side of the seat must face the ball.
Repair

a. Orient the pump so one of the fluid covers faces up. Use a 17 mm socket wrench to remove the fluid cover screws (5, 6), then pull the fluid cover (2) up off the pump. Turn the pump over and remove the other fluid cover.
b. Hold the hex of one fluid side diaphragm plate (15) with a 1–1/2 socket or box end wrench. Use another wrench (same size) on the hex of the other plate to remove. Then remove all parts of each diaphragm assembly.
Disassemble the Diaphragm and Center Section
a. Orient the pump so one of the fluid covers (2) faces up. Use a 17 mm socket wrench to remove the fluid cover bolts (5, 6), then pull the fluid cover up off the pump.
b. The exposed diaphragm (12) will screw off by hand. The shaft will either release and come off with this diaphragm, or remain attached to the other diaphragm. If the diaphragm shaft bolt (14) remains attached to the shaft (108), remove it. Remove the air side diaphragm plate (11) and washer (17).
c. Turn the pump over and remove the other fluid cover. Remove the diaphragm (and the shaft, if necessary).
d. If the shaft is still attached to either diaphragm, grasp the diaphragm firmly and use a wrench on the flats of the shaft to remove. Also remove the air side diaphragm plate (11) and washer (17). Continue with Step 5.
Repair

Reassemble the Diaphragm and Center Section
Follow all notes in the illustration. These notes contain important information.
e. Grease the shaft u-cups (106*) and the length and ends of the diaphragm shaft (108*). Slide the shaft into the housing.
f. Reattach one fluid cover (3). Arrow (A) must point toward the air valve. See Torque Instructions, page 19.
g. Repeat Steps b-d for the other diaphragm assembly and install on the exposed end of the shaft.
h. Tighten by hand as much as possible. Go to Step 8.
a. Assemble the diaphragm (12), the backup diaphragm (13, if present), the air side diaphragm plate (11), and the washer (17) on the fluid side plate (10) exactly as shown.
b. Apply primer and medium-strength (blue) thread locker to the threads of the screw on the fluid side plate. Screw the assembly into the shaft hand-tight.
c. Grease the shaft u-cups (106*) and the length and ends of the diaphragm shaft (108*). Slide the shaft into the housing.
a. Clamp the shaft flats in a vise.
d. Repeat for the other diaphragm assembly and install on the exposed end of the shaft.
b. If diaphragm setscrew comes loose or is replaced, apply permanent (red) thread locker to diaphragm side threads. Screw into diaphragm until tight.
e. Hold one of the plates with a wrench, and torque the other plate to 65–70 ft-lb (88–95 N•m) at 100 rpm maximum. Do not over-torque.
c. Assemble the air side plate (11) and washer (17) onto the diaphragm. The rounded side of the plate must face the diaphragm.
f. Reattach one fluid cover (3). Arrow (A) must point toward the air valve. See Torque Instructions, page 19.
d. Apply primer and medium-strength (blue) thread locker to the threads of the diaphragm assembly. Screw the assembly into the shaft as tight as possible by hand.
Repair

SP and FK Models PO Models


PT Models Rounded side faces diaphragm
Apply lithium based grease.

Apply primer and medium-strength (blue) thread locker. Torque to 65-70 ft-lb (88–95 N•m).
AIR SIDE markings on diaphragm must face center housing.
If screw comes loose or is replaced, apply permanent (red) thread locker to diaphragm side threads. Apply primer and medium-strength (blue) thread locker to shaft side threads.
Lips must face out of housing.
Cartridges (109) must be installed before pilot valves (111).
Torque to 20-25 in.-lb (2-3 N•m).

Repair

c. Supply a minimum of 20 psi (0.14 MPa, 1.4 bar) air pressure to the air valve. Shop air may be used. The diaphragm will shift so the second fluid cover will seat properly. Keep air pressure on until the second fluid cover is attached.
a. Place the supplied tool (302) where the air valve gasket (105) normally goes. Arrows (A) must face toward the fluid cover that is already attached.
d. Attach the second fluid cover (3). See Torque Instructions, page 19.

e. Remove the air valve and the tool (302), replace the gasket (105), and reattach the air valve. See Torque Instructions, page 19.
f. Reassemble the ball check valves and manifolds as explained in Check Valve Repair, page 14.
Figure 2 Fluid cover tool
b. Reattach the air valve.
Repair

If fluid cover or manifold fasteners have been loosened, it is important to torque them using the following procedure to improve sealing.
Inlet and Outlet Manifold Screws

Air Valve Screws and Pilot Valves


Torque Instructions · Fluid Cover Screws



Use this table as a quick reference for parts/kits. Go to the pages indicated in the table for a full description of kit contents.


11 24W231 Air Side Diaphragm Plate; includes washer (Ref. 17); see page 29
24W220 PTFE/Santoprene 2-Piece, bolt-through; includes backup diaphragm (Ref. 13)
6 24W211 Fluid Cover Fastener Kit; see page 26
▲Replacement Warning labels, signs, tags, and cards are available at no cost.



101 HOUSING, center, not sold separately
108* SHAFT, center 1
109* CARTRIDGE, pilot receiver 2
102 VALVE, air, see page 24 1
110* O-RING, Buna-N 2
103 SCREW, hi-lo stud 4
111* VALVE, pilot, assembly 2
104* NUT, hex, flange, serrated 4
105* GASKET, air valve 1
113* RING, retaining 2
106* U-CUP, center shaft 2
107* BEARING, shaft 2
* Included in Center Section Rebuild Kit.
Sample Configuration Number · Ref Description Qty · Ref Description Qty

Center Section and Air Valve
Seats Balls Diaphragms Seat and Manifold Seal
Center Section Rebuild Kits (*)
Center Shaft Kits (*)
P01A with 2–Piece diaphragms (PT) or standard diaphragms (SP, FK)
P01A with 2–Piece diaphragms (PT) or standard diaphragms (SP, FK)
PO1G with overmolded diaphragms (PO)
PO1G with overmolded diaphragms (PO)
Kits include:
Kits include:
Center Shaft Bearing Kit
Kit includes:
Pilot Valve Assembly Kit
Kit includes:


201 HOUSING, not sold separately
209✦✝ SCREW, #4, thread forming 2
210‡ RETAINING RING 2
203✦ PISTON ASSEMBLY, detent 1
211✦ SPRING, detent 1
204✦ CAM, detent 1
212✦ BASE, cup 1
205✦ PLATE, air valve 1
206 ✦✝ ‡ O-RING 2
214✦ O-RING, cup 1
207‡ CAP, end 2
✦Parts included in Air Valve Repair Kit.
‡ Parts included in Air Valve End Cap Kit.
✝Parts included in Air Valve Seals Kit..
Sample Configuration Number · Ref Description Qty · Ref Description Qty

Center Section and Air Valve
Seats Balls Diaphragms Seat and Manifold Seal
✝Air Valve Seals Kit
Air Valve Replacement Kit
Kit includes:
Kits include:
‡ Air Valve End Cap Kit
Kit includes:
✦Air Valve Repair Kit
Kit includes:




Kits include 1 manifold (4)
Kits include 1 fluid cover (2)
Fluid Cover Fastener Kits

Kit includes:
Kits include 1 manifold

Kit includes:
Kits include 1 manifold (3)

Center Section and Air Valve
Seats Balls Diaphragms Seat and Manifold Seal
FK 24W230
SS 24W227
PT 24W228
SP 24W226
SP 24W229
PV 24W223
Kits include:
Kits include:


1–Piece Bolt-Through Diaphragm Kits
SP 24W218
FK 24W219
Kits include:
Kits include:


Sample Configuration Number · Overmolded Diaphragm Kit


2-Piece Bolt-Through Diaphragm Kit
PT 24W220
F2 24W222
Kits include:
Kits include:
Kits include:


Center Section and Air Valve
Seats Balls Diaphragms Seat and Manifold Seal
Kits include:

Muffler 111897 Legacy or remote exhaust muffler option.
Replacement Air Valve Kit 24B774, Polypropylene, DataTrak Compatible Kit includes nuts, valve, and gasket.
Accessories

Husky 15120 Diaphragm Pump
Maximum fluid working pressure 125 psi 0.86 MPa, 8.6 bar
Air pressure operating range 20 to 125 psi 0.14 to 0.86 MPa, 1.4 to 8.6 bar
Air inlet size 1/2 in. (npt(f)
Air exhaust size 1 in.
Fluid inlet and outlet size (ANSI/DIN flange)
1.5 in 38 mm
Maximum suction lift (reduced if balls don’t seat well due to damaged balls or seats, lightweight balls, or extreme speed of cycling)
Maximum size pumpable solids 1/4 in. 6.3 mm
Minimum ambient air temperature for operation and storage. NOTE: Exposure to extreme low temperatures may result in damage to plastic parts.
Air Consumption 43 scfm at 70 psi, 60 gpm 1.2 m3/min at 0.48 MPa, 4.8 bar, 227 lpm
Maximum Air Consumption 85 scfm 2.4 m3/min
Noise (dBa) Sound power measured per ISO-9614–2. Sound pressure was tested 3.28 ft (1 m) from equipment.
90.9 at 70 psi and 50 cpm 90.9 at 4.8 bar and 50 cpm Sound Power
102.1 at 100 psi and full flow 102.1 at 7.0 bar and full flow
83.6 at 70 psi and 50 cpm 83.6 at 4.8 bar and 50 cpm Sound Pressure
95.7 at 100 psi and full flow 95.7 at 7.0 bar and full flow
Fluid flow per cycle
1–piece bolt-through diaphragms 0.63 gallons 2.4 liters
2–piece bolt-through diaphragms 0.66 gallons 2.5 liters
Overmolded diaphragms 0.59 gallons 2.3 liters
1–piece bolt-through diaphragms 122 gpm 462 lpm
2–piece bolt-through diaphragms 120 gpm 454 lpm
Overmolded diaphragms 115 gpm 435 lpm
Technical Data · US Metric · Maximum free-flow delivery


Wetted parts include material(s) chosen for seat, ball, and diaphragm options, plus the pump’s material of construction: Polypropylene or PVDF

FKM Fluoroelastomer 32° to 150° 32° to 225° 0° to 66° 0° to 107°
Polypropylene 32° to 150° 32° to 150° 0° to 66° 0° to 66°
PTFE overmolded diaphragm 40° to 150° 40° to 180° 4° to 66° 4° to 82°
PTFE check balls 40° to 150° 40° to 220° 4° to 66° 4° to 104°
PVDF 32° to 150° 32° to 225° 0° to 66° 0° to 107°
Santoprene 32° to 150° 32° to 180° 0° to 66° 0° to 82°
40° to 150° 40° to 180° 4° to 66° 4° to 82°
Technical Data · Fluid Temperature Range

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of five years from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within six (6) years of the date of sale..
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties..
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com For patent information, see www.graco.com/patents
To place an order, contact your Graco Distributor or call to identify the nearest distributor.
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original Instructions. This manual contains English. MM 3A2889
Copyright 2014, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
Pages referenced in this manual — manufacturer, support and downloads.
Common problems, likely causes, and what to do.
| Problem | Possible cause | Remedy | |
|---|---|---|---|
| Pump cycles but will not prime. | Pump is running too fast, causing cavitation before prime. | Reduce air inlet pressure. | p.8 |
| Pump cycles but will not prime. | Check valve ball severely worn or wedged in seat or manifold. | Replace ball and seat. | p.8 |
| Pump cycles but will not prime. | Seat severely worn. | Replace ball and seat. | p.8 |
| Pump cycles but will not prime. | Outlet or inlet clogged. | Unclog. | p.8 |
| Pump cycles but will not prime. | Inlet or outlet valve closed. | Open. | p.8 |
| Pump cycles but will not prime. | Inlet fittings or manifolds loose. | Tighten. | p.8 |
| Pump cycles but will not prime. | Manifold o-rings damaged. | Replace o-rings. | p.8 |
| Pump cycles at stall or fails to hold pressure at stall. | Worn check valve balls, seats, or o-rings. | Replace. | p.8 |
| Pump will not cycle, or cycles once and stops. | Air valve is stuck or dirty. | Disassemble and clean air valve. Use filtered air. | p.8 |
| Pump will not cycle, or cycles once and stops. | Check valve ball severely worn and wedged in seat or manifold. | Replace ball and seat. | p.8 |
| Pump will not cycle, or cycles once and stops. | Pilot valve worn, damaged, or plugged. | Replace pilot valve. | p.8 |
| Pump will not cycle, or cycles once and stops. | Air valve gasket damaged. | Replace gasket. | p.8 |
| Pump will not cycle, or cycles once and stops. | Dispensing valve clogged. | Relieve pressure and clear valve. | p.8 |
| Pump operates erratically. | Clogged suction line. | Inspect; clear. | p.8 |
| Pump operates erratically. | Sticky or leaking check valve balls. | Clean or replace.. | p.8 |
| Pump operates erratically. | Diaphragm (or backup) ruptured. | Replace. | p.8 |
| Pump operates erratically. | Restricted exhaust. | Remove restriction. | p.8 |
| Pump operates erratically. | Pilot valves damaged or worn. | Replace pilot valves. | p.8 |
| Pump operates erratically. | Air valve damaged. | Replace air valve. | p.8 |
| Pump operates erratically. | Air valve gasket damaged. | Replace air valve gasket. | p.8 |
| Pump operates erratically. | Air supply erratic. | Repair air supply. | p.8 |
| Pump operates erratically. | Exhaust muffler icing. | Use drier air supply. | p.8 |
| Air bubbles in fluid. | Suction line is loose. | Tighten. | p.9 |
| Air bubbles in fluid. | Diaphragm (or backup) ruptured. | Replace. | p.9 |
| Air bubbles in fluid. | Loose manifolds, damaged seats or o-rings. | Tighten manifold bolts or replace seats or o-rings. | p.9 |
| Air bubbles in fluid. | Pump cavitation. | Reduce pump speed or suction lift. | p.9 |
| Air bubbles in fluid. | Loose diaphragm shaft bolt. | Tighten. | p.9 |
| Exhaust air contains fluid being pumped. | Diaphragm (or backup) ruptured. | Replace. | p.9 |
| Exhaust air contains fluid being pumped. | Loose diaphragm shaft bolt. | Tighten or replace. | p.9 |
| Moisture in exhaust air. | High inlet air humidity. | Use drier air supply. | p.9 |
| Pump exhausts excessive air at stall. | Worn air valve cup or plate. | Replace cup and plate. | p.9 |
| Pump exhausts excessive air at stall. | Damaged air valve gasket. | Replace gasket. | p.9 |
| Pump exhausts excessive air at stall. | Damaged pilot valve. | Replace pilot valves. | p.9 |
| Pump exhausts excessive air at stall. | Worn shaft seals or bearings. | Replace shaft seals or bearings. | p.9 |
| Pump leaks air externally. | Air valve or fluid cover screws loose. | Tighten. | p.9 |
| Pump leaks air externally. | Diaphragm damaged. | Replace diaphragm. | p.9 |
| Pump leaks air externally. | Air valve gasket damaged. | Replace gasket. | p.9 |
| Pump leaks fluid externally from joints. | Loose manifold screws or fluid cover screws. | Tighten manifold screws or fluid cover screws. | p.9 |
| Pump leaks fluid externally from joints. | Manifold o-rings worn out. | Replace o-rings. | p.9 |