Operation

Husky ™1050HP 2:1

Air-Operated Diaphragm Pump 334014A EN

1–inch high-pressure pump with modular air valve for fluid transfer applications. For professional use only.

Graco 334014A — Operation diagram (page 1)
Fig. 1 · Operation
Maximum Fluid Working Pressure200 psi (1.38 MPa, 13.8 bar)
Maximum Air Input Pressure100 psi (0.69 MPa, 6.9 bar)

PROVEN QUALITY. LEADING TECHNOLOGY.

Page 3 of the Graco 334014A user manual — To Order Replacement Parts
Page 3 · click to enlarge
Page 3

Ordering Information

To Find Your Nearest Distributor

Distributor Note

1. Visit www.graco.com.
1. To find part numbers for replacement parts:
2. Click on Where to Buy and use the Distributor Locator.

a. Use the 20–digit number from the ID plate on the pump.

b. Use the Configuration Number Matrix on the next page to understand which parts are described by each digit.

To Specify the Configuration of a New Pump

c. Use the Repair/Parts Manual. Refer to the main Parts illustration and to the Parts/Kits Quick Reference. Follow the page references on these two pages for further ordering information, as needed.

Please call your distributor.

To Order Replacement Parts

2. Please call Graco Customer Service to order.

Please call your distributor.

Ordering Information

Page 4 of the Graco 334014A user manual — Configuration Number Matrix
Page 4 · click to enlarge
Page 4

Configuration Number Matrix

Graco 334014A — Configuration Number Matrix diagram (page 4)
Fig. 2 · Configuration Number Matrix

Check the identification plate (ID) for the 20–digit Configuration Number of your pump. Use the following matrix to define the components of your pump.

Sample Configuration Number:

Graco 334014A — Configuration Number Matrix diagram (page 4)
Fig. 3 · Configuration Number Matrix
1050HPA01AA1SSSPSP Pump ModelCenter Section and Air ValveManifoldsSeatsBallsDiaphragms
Graco 334014A — Configuration Number Matrix diagram (page 4)
Fig. 4 · Configuration Number Matrix
PumpCenter Section and Air Valve MaterialAir ValveManifolds 1050HP AluminumAluminumA01AStandardA1 Alumin A2 Alumin S1 Stainle S2 Stainleum, standard ports, npt um, standard ports, bsp ss steel, standard ports, npt ss steel, standard ports, bsp
Check Valve SeatsCheck Valve BallsDiaphragm Material Manifold O-Rings SS316 Stainless SteelSPSantopreneSPSantoprene PT PTFE

Configuration Number Matrix

Page 5 of the Graco 334014A user manual — PRESSURIZED EQUIPMENT HAZARD
Page 5 · click to enlarge
Page 5

Warnings

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.

WARNING

FIRE AND EXPLOSION HAZARD

Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:

  • Use equipment only in well ventilated area.
  • Eliminate all ignition sources; such as pilot lights, cigarettes, portable electric lamps, and plastic drop cloths (potential static arc).
  • Keep work area free of debris, including solvent, rags and gasoline.
  • Do not plug or unplug power cords, or turn power or light switches on or off when flammable fumes are present.
  • Ground all equipment in the work area. See Grounding instructions.
  • Use only grounded hoses.
  • Hold gun firmly to side of grounded pail when triggering into pail. Do not use pail liners unless they are antistatic or conductive.
  • Stop operation immediately if static sparking occurs or you feel a shock. Do not use equipment until you identify and correct the problem.
  • Keep a working fire extinguisher in the work area.
  • Route exhaust away from all ignition sources. If diaphragm ruptures, fluid may be exhausted with air.

PRESSURIZED EQUIPMENT HAZARD

Fluid from the equipment, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury.

  • Follow the Pressure Relief Procedure when you stop spraying/dispensing and before cleaning, checking, or servicing equipment.
  • Tighten all fluid connections before operating the equipment.
  • Check hoses, tubes, and couplings daily. Replace worn or damaged parts immediately.
Page 6 of the Graco 334014A user manual — Warnings
Page 6 · click to enlarge
Page 6
WARNING EQUIPMENT MISUSE HAZARD Misuse can cause death or serious injury. • Do not operate the unit when fatigued or under the influence of drugs or alcohol. • Do not exceed the maximum working pressure or temperature rating of the lowest rated system component. See Technical Data in all equipment manuals. • Use fluids and solvents that are compatible with equipment wetted parts. See Technical Data in all equipment manuals. Read fluid and solvent manufacturer’s warnings. For complete information about your material, request MSDS from distributor or retailer. • Do not leave the work area while equipment is energized or under pressure. • Turn off all equipment and follow the Pressure Relief Procedure when equipment is not in use. • Check equipment daily. Repair or replace worn or damaged parts immediately with genuine manufacturer’s replacement parts only. • Do not alter or modify equipment. Alterations or modifications may void agency approvals and create safety hazards. • Make sure all equipment is rated and approved for the environment in which you are using it. • Use equipment only for its intended purpose. Call your distributor for information. • Route hoses and cables away from traffic areas, sharp edges, moving parts, and hot surfaces. • Do not kink or over bend hoses or use hoses to pull equipment. • Keep children and animals away from work area. • Comply with all applicable safety regulations. THERMAL EXPANSION HAZARD Fluids subjected to heat in confined spaces, including hoses, can create a rapid rise in pressure due to the thermal expansion. Over-pressurization can result in equipment rupture and serious injury. • Open a valve to relieve the fluid expansion during heating. • Replace hoses proactively at regular intervals based on your operating conditions. PLASTIC PARTS CLEANING SOLVENT HAZARD Many solvents can degrade plastic parts and cause them to fail, which could cause serious injury or property damage. • Use only compatible water-based solvents to clean plastic structural or pressure-containing parts. • See Technical Data in this and all other equipment instruction manuals. Read fluid and solvent manufacturer’s MSDSs and recommendations.
Page 7 of the Graco 334014A user manual — Warnings
Page 7 · click to enlarge
Page 7
WARNING TOXIC FLUID OR FUMES HAZARD Toxic fluids or fumes can cause serious injury or death if splashed in the eyes or on skin, inhaled, or swallowed. • Read MSDSs to know the specific hazards of the fluids you are using. • Route exhaust away from work area. If diaphragm ruptures, fluid may be exhausted into the air. • Store hazardous fluid in approved containers, and dispose of it according to applicable guidelines. BURN HAZARD Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe burns: • Do not touch hot fluid or equipment. PERSONAL PROTECTIVE EQUIPMENT Wear appropriate protective equipment when in the work area to help prevent serious injury, including eye injury, hearing loss, inhalation of toxic fumes, and burns. This protective equipment includes but is not limited to: • Protective eyewear, and hearing protection. • Respirators, protective clothing, and gloves as recommended by the fluid and solvent manufacturer.
Page 8 of the Graco 334014A user manual — Mounting
Page 8 · click to enlarge
Page 8

Grounding

The Typical Floor Mount Installation, page 12, is only a guide for selecting and installing system components. Contact your Graco distributor for assistance in planning a system to suit your needs.

Graco 334014A — Grounding diagram (page 8)
Fig. 5 · Grounding

Tighten Fasteners Before Setup

The equipment must be grounded to reduce the risk of static sparking. Static sparking can cause fumes to ignite or explode. Grounding provides an escape wire for the electric current.

Before using the pump for the first time, check and retorque all external fasteners. Follow Torque Instructions, page 16. After the first day of operation, retorque the fasteners.

  • Pump: Loosen the grounding screw (GS). Insert one end of a 12 ga. minimum ground wire (R) behind the grounding screw and tighten the screw securely. Connect the clamp end of the ground wire to a true earth ground. A ground wire and clamp, Part 238909, is available from Graco.

Mounting

  • The pump exhaust air may contain contaminants. Ventilate to a remote area. See Air Exhaust Ventilation, page 10 .
Graco 334014A — Mounting diagram (page 8)
Fig. 6 · Mounting
  • Never move or lift a pump under pressure. If dropped, the fluid section may rupture. Always follow the Pressure Relief Procedure, page 13 , before moving or lifting the pump.
1. Be sure the mounting surface can support the weight of the pump, hoses, and accessories, as well as the stress caused during operation.
2. For all mountings, be sure the pump is bolted directly to the mounting surface. Mount the pump horizontally, with the feet at the bottom of the pump. Do not mount the pump on a vertical surface, such as a wall.

Figure 1 Grounding Screws and Wires

3. For ease of operation and service, mount the pump so air valve, air inlet, fluid inlet and fluid outlet ports are easily accessible.
Page 9 of the Graco 334014A user manual — Air Line
Page 9 · click to enlarge
Page 9
  • Air and fluid hoses: Use only grounded hoses with a maximum of 500 ft (150 m) combined hose length to ensure grounding continuity.

gauge to control the fluid pressure. The fluid stall pressure will be the same as the setting of the air regulator.

  • Air compressor: Follow manufacturer’s recommendations.
2. Locate a bleed-type master air valve (B) close to the pump and use it to relieve trapped air. Be sure the valve is easily accessible from the pump and located downstream from the regulator.
  • Fluid supply container: Follow your local code.
  • Solvent pails used when flushing: Follow your local code. Use only conductive metal pails placed on a grounded surface. Do not place the pail on a nonconductive surface, such as paper or cardboard, which interrupts the grounding continuity

Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury from splashing.

Check your system electrical continuity after the initial installation, and then set up a regular schedule for checking continuity to be sure proper grounding is maintained.

3. Locate another master air valve (E) upstream from all air line accessories and use it to isolate them during cleaning and repair.
4. An adjustable inlet air valve or needle valve (G) my be installed for pump speed control.

Air Line

5. Install a grounded, flexible air hose (A) between the accessories and the 3/4 npt(f) pump air inlet (D). Use a minimum 5/8 in. (16 mm) ID air hose.

See Typical Floor Mount Installation, page 12

1. Install an air filter/regulator (C). An air line filter removes harmful dirt and moisture from the compressed air supply. Use the regulator and
Page 10 of the Graco 334014A user manual — KEY
Page 10 · click to enlarge
Page 10

Air Exhaust Ventilation

2. Install a grounded air exhaust hose (U). Connect the muffler (T) to the other end of the hose. The minimum size for the air exhaust hose is 3/4 in. (19 mm) ID. If a hose longer than 15 ft (4.57 m) is required, use a larger diameter hose. Avoid sharp bends or kinks in the hose.

The air exhaust port is 3/4 npt(f). Do not restrict the air exhaust port. Excessive exhaust restriction can cause erratic pump operation.

3. Place a container at the end of the air exhaust line to catch fluid in case a diaphragm ruptures. If the diaphragm ruptures, the fluid being pumped will exhaust with the air.

To provide a remote exhaust:

1. Remove the muffler (T) from the pump air exhaust port.
Graco 334014A — Air Exhaust Ventilation diagram (page 10)
Fig. 7 · Air Exhaust Ventilation

Figure 2 Vent exhaust air

KEY

A Air supply line G Optional needle valve for pump speed adjustment.

B Bleed-type master air valve T Muffler

C Air filter/regulator U Grounded air exhaust hose

D Air inlet V Container for remote air exhaust

E Master air valve (for accessories)

Page 11 of the Graco 334014A user manual — Fluid Inlet and Outlet Ports
Page 11 · click to enlarge
Page 11

Fluid Supply Line

Fluid Outlet Line

See Typical Floor Mount Installation, page 12

See Typical Floor Mount Installation, page 12.

1. Use grounded flexible, fluid supply hoses (G). See Grounding, page 8 .
1. Use grounded, flexible fluid hoses (L). See Grounding, page 8 .
2. If the inlet fluid pressure to the pump is more than 25% of the outlet working pressure, the ball check valves will not close fast enough, resulting in inefficient pump operation.
2. Install a fluid drain valve (J) near the fluid outlet.
3. Install a shutoff valve (K) in the fluid outlet line.

Fluid Inlet and Outlet Ports

3. Excessive inlet fluid pressure also will shorten diaphragm life. Approximately 3 - 5 psi (0.020.03 MPa, 0.21-0.34 bar) should be adequate for most materials.
4. For maximum suction lift (wet and dry), see Technical Data, page 20 . For best results, always install the pump as close as possible to the material source.

1050HP — Aluminum Manifolds

The fluid inlet and outlet manifolds each have two 1 in. npt(f) or bspt threaded ports (M, N). Close off the unused port using the supplied plugs.

1050HP — Stainless Steel Manifolds

The fluid inlet and outlet manifolds each have one 1 in. npt(f) or bspt port.

Page 12 of the Graco 334014A user manual — KEY
Page 12 · click to enlarge
Page 12

Typical Floor Mount Installation

Graco 334014A — Typical Floor Mount Installation diagram (page 12)
Fig. 8 · Typical Floor Mount Installation

Figure 3 Typical floor mount installation

KEY

A Air supply line J Fluid drain valve (required)

B Bleed-type master air valve (required for pump)

K Fluid shutoff valve

C Air filter and regulator L Flexible fluid outlet hose

D Air inlet M Fluid inlet (2 ports on aluminum manifolds,1 port on SST manifolds)

E Master air valve (for accessories) N Fluid outlet (2 ports on aluminum manifolds,1 port on SST manifolds)

F Flexible fluid suction hose R Ground wire (required; see Grounding, page 8 ).

G Optional needle valve for pump speed adjustment.

Page 13 of the Graco 334014A user manual — High/Low Lever
Page 13 · click to enlarge
Page 13

Operation

Pressure Relief Procedure

4. Open the fluid drain valve (installed on the system) to relieve all fluid pressure. Have a container ready to catch the drainage.
Graco 334014A — Pressure Relief Procedure diagram (page 13)
Fig. 9 · Pressure Relief Procedure

Follow the Pressure Relief Procedure whenever you see this symbol.

Tighten Fasteners Before Setup

Before using the pump for the first time, check and retorque all external fasteners. Follow Torque Instructions, page 16. After the first day of operation, retorque the fasteners.

This equipment stays pressurized until pressure is relieved manually. To help prevent serious injury from pressurized fluid, such as splashing in the eyes or on skin, follow the Pressure Relief Procedure when you stop pumping and before you clean, check, or service the equipment.

Flush the Pump Before First Use

The pump was tested in water. If water could contaminate the fluid you are pumping, flush the pump thoroughly with a compatible solvent. See Flushing and Storage, page 15.

1. Shut off the air supply to the pump.
2. Open the dispensing valve, if used.
3. Shift the high/low pressure lever back and forth two times. Leave the lever in the “Low” position as shown.
Graco 334014A — Flush the Pump Before First Use diagram (page 13)
Fig. 10 · Flush the Pump Before First Use

High/Low Lever

Use the High/Low lever to set the desired pressure mode. When the lever is set to “Low,” the fluid outlet pressure is slightly less than the air inlet pressure. When the lever is set to “High,” the fluid outlet pressure is slightly less than two times the inlet air pressure. Note that the High pressure setting increases both fluid outlet pressure and inlet air consumption.

Operation

Page 14 of the Graco 334014A user manual — NOTICE
Page 14 · click to enlarge
Page 14

Start and Adjust the Pump

9. Slowly increase air pressure with the air regulator until the pump starts to cycle. Allow the pump to cycle slowly until all air is pushed out of the lines and the pump is primed.
1. Be sure the pump is properly grounded. Refer to Grounding, page 8 .
2. Ensure the High/Low pressure lever is in the “Low” position before starting the pump.
3. Check all fittings to be sure they are tight. Use a compatible liquid thread sealant on all male threads. Tighten fluid inlet and outlet fittings securely.
10. If you are flushing, run the pump long enough to thoroughly clean the pump and hoses.
11. Close the dispensing valve, if used.
4. Place the suction tube (if used) in the fluid to be pumped.
12. Close the bleed-type master air valve.

Pump Shutdown

NOTICE

Excessive fluid inlet pressure can reduce diaphragm life and may result in pump damage.

At the end of the work shift and before you check, adjust, clean or repair the system, follow the Pressure Relief Procedure, page 13.

5. Place the end of the fluid hose into an appropriate container.
6. Close the fluid drain valve.
7. Turn the air regulator knob to 0. Open all bleed-type master air valves.
8. If the fluid hose has a dispensing device, hold it open.

Operation

Page 15 of the Graco 334014A user manual — Tighten Threaded Connections
Page 15 · click to enlarge
Page 15

Maintenance

Maintenance Schedule

Flushing and Storage

Establish a preventive maintenance schedule, based on the pump’s service history. Scheduled maintenance is especially important to prevent spills or leakage due to diaphragm failure.

  • Flush before fluid can dry in the equipment, at the end of the day, before storing, and before repairing equipment.

Lubrication

The pump is lubricated at the factory. It is designed to require no further lubrication for the life of the pump. An inline lubricator is not needed, and is not recommended, under normal operating conditions.

  • Flush at the lowest pressure possible. Check connectors for leaks and tighten as necessary.
  • Flush with a fluid that is compatible with the fluid being dispensed and the equipment wetted parts.

Flush the pump often enough to prevent the fluid you are pumping from drying or freezing in the pump and damaging it. Use a compatible solvent.

Tighten Threaded Connections

Before each use, check all hoses for wear or damage, and replace as necessary. Check to be sure all threaded connections are tight and leak-free. Check fasteners. Tighten or retorque as necessary. Although pump use varies, a general guideline is to retorque fasteners every two months. See Torque Instructions, page 16.

Always flush the pump and relieve the pressure before storing it for any length of time.

Maintenance

Page 16 of the Graco 334014A user manual — Torque Instructions
Page 16 · click to enlarge
Page 16

Torque Instructions

Fluid cover, center diaphragm joint, and manifold fasteners: 100 in-lb (11.3 N•m)

Lubricate air valve fasteners prior to reassembly to prevent galling. Retorque the air valve fasteners in a crisscross pattern to specified torque.

Air valve fasteners80 in-lb (9.0 N•m)

If fluid cover, center diaphragm joint, or manifold fasteners have been loosened, it is important to torque them using the following procedure to improve sealing.

Graco 334014A — Torque Instructions diagram (page 16)
Fig. 11 · Torque Instructions

Start all fluid cover or center diaphragm joint screws a few turns. Then turn down each screw just until head contacts cover. Then turn each screw by 1/2 turn or less working in a crisscross pattern to specified torque. Repeat for manifolds.

Graco 334014A — Torque Instructions diagram (page 16)
Fig. 12 · Torque Instructions
Graco 334014A — Torque Instructions diagram (page 16)
Fig. 13 · Torque Instructions

Fluid Covers and Center Diaphragm Joint Manifolds

Maintenance · Air Valve Fasteners

Page 17 of the Graco 334014A user manual — KEY
Page 17 · click to enlarge
Page 17

Dimensions and Mounting

KEY

Aluminum SST Aluminum and SST

A 12.7 in (323 mm) 11.8 in (300 mm) H 6.2 in (157 mm)

B 14.4 in (366 mm) 12.9 in (328 mm) J 9.4 in (239 mm)

C 15.3 in (389 mm) 13.7 in (348 mm) K 15.6 in (396 mm)

D 10.9 in (277 mm) 9.5 in (241 mm) L 3/4 npt(f) Air Inlet

E 1.8 in (46 mm) 1.1 in (28 mm) M 1 in npt(f) or 1 in. bspt Fluid Inlet (2 for aluminum manifolds; 1 for SST manifolds) F 10.8 in (274 mm) 10.7 in (272 mm) N 1 in npt(f) or 1 in. bspt Fluid Outlet (2 for aluminum manifolds; 1 for SST manifolds) G 21.5 in (546 mm) 20.6 in (523 mm) P 3/4 npt(f) Air Exhaust Port

Graco 334014A — KEY diagram (page 17)
Fig. 14
Graco 334014A — KEY diagram (page 17)
Fig. 15

Dimensions and Mounting

Page 18 of the Graco 334014A user manual — D
Page 18 · click to enlarge
Page 18

Performance Charts

Low Pressure Setting

Fluid Pressure

Approximate Cycles per Minute

56 112 168 224 280

100 (0.70, 7.0)

80 (0.55, 5.5)

60 (0.41, 4.1)

A 100 psi (0.7 MPa, 7.0 bar)

B

40 (0.28, 2.8)

B 70 psi (0.48 MPa, 4.8 bar)

20 (0.14, 1.4)

C 40 psi (0.28 MPa, 2.8 bar)

D

D 20 psi (0.14 MPa, 1.4 bar)

Fluid Flow — gpm (lpm)

How to Read the Charts

Air Consumption

1. Locate fluid flow rate along bottom of chart.

Approximate Cycles per Minute

56 112 168 224 280

2. Follow vertical line up to intersection with selected operating air pressure curve.

75 (2.1)

60 (1.7)

3. Follow left to scale to read fluid outlet pressure (top chart) or air consumption (bottom chart)

45 (1.3)

scfm (Nm3/min.)

30 (0.8)

B

15 (0.4)

D

Fluid Flow — gpm (lpm)

Show 13 more labels / short text on this page
Performance Charts · Operating Air Pressure · PSI (MPa, bar) · 0 10 (38) · 20 (76) · 30 (114) · 40 (151) · 50 (189) · 0 10 (38) · 20 (76) · 30 (114) · 40 (151) · 50 (189)
Page 19 of the Graco 334014A user manual — D
Page 19 · click to enlarge
Page 19

High Pressure Setting

Fluid Pressure

Approximate Cycles per Minute

50 100 150 200 250

200 (1.38, 13.8)

160 (1.10, 11.0)

120 (0.83, 8.3)

A 100 psi (0.7 MPa, 7.0 bar)

80 (0.55, 5.5)

B

B 70 psi (0.48 MPa, 4.8 bar)

40 (0.28, 2.8)

C 40 psi (0.28 MPa, 2.8 bar)

D

D 20 psi (0.14 MPa, 1.4 bar)

Fluid Flow — gpm (lpm)

How to Read the Charts

Air Consumption

1. Locate fluid flow rate along bottom of chart.

Approximate Cycles per Minute

50 100 150 200 250

2. Follow vertical line up to intersection with selected operating air pressure curve.

120 (3.4)

96 (2.7)

3. Follow left to scale to read fluid outlet pressure (top chart) or air consumption (bottom chart)

72 (2.0)

scfm (Nm3/min.)

B

48 (1.4)

24 (0.7)

D

Fluid Flow — gpm (lpm)

Show 13 more labels / short text on this page
Performance Charts · Operating Air Pressure · PSI (MPa, bar) · 0 10 (38) · 20 (76) · 30 (114) · 40 (151) · 50 (189) · 0 10 (38) · 20 (76) · 30 (114) · 40 (151) · 50 (189)
Page 20 of the Graco 334014A user manual — Technical Data
Page 20 · click to enlarge
Page 20

Technical Data

Maximum fluid working pressure 200 psi 1.4 MPa,14.0 bar

Air pressure operating range 20-100 psi 0.14-0.69 MPa, 1.4-6.9 bar

Fluid displacement per cycle

Low Pressure Setting 0.17 g 0.64 l

High Pressure Setting 0.20 g 0.76 l

Air consumption at 70 psi, 20 gpm at 4.8 bar, 76 lpm

Low Pressure Setting 26 scfm 0.7 cubic meters per minute

High Pressure Setting 51 scfm 1.4 cubic meters per minute

Maximum values with water as media under submerged inlet conditions at ambient temperature:

Low Pressure Setting 59 scfm 1.7 cubic meters per minute

High Pressure Setting 95 scfm 2.7 cubic meters per minute

Low Pressure Setting 50 gpm 189 lpm

High Pressure Setting 46 gpm 174 lpm

Low Pressure Setting 280 cpm

High Pressure Setting 225 cpm

Maximum suction lift (varies widely based on ball/seat selection and wear, operating speed, material properties, and other variables)

16 ft dry, 29 ft wet 4.9 m dry 8.8 m wet

Maximum size pumpable solids 1/8 in 3.2 mm

Recommended cycle rate for continuous use

93–140 cpm (in Low or High pressure setting) Recommended cycle rate for circulation systems

20 cpm (in Low or High pressure setting) Air inlet size 3/4 npt(f)

Fluid inlet size 1 in. npt(f) or 1 in. bspt

Fluid outlet size 1 in. npt(f) or 1 in. bspt

Weight 48 lb (aluminum manifolds) 60 lb (SST manifolds) 21.8 kg (aluminum manifolds) 27.2 kg (SST manifolds)

Show 5 more labels / short text on this page
Technical Data · US Metric · Maximum air consumption · Maximum free-flow delivery · Maximum pump speed
Page 21 of the Graco 334014A user manual — NOTICE
Page 21 · click to enlarge
Page 21

Sound Power (measured per ISO-9614–2)

At 70 psi (0.48 MPa, 4.8 bar) and 50 cpm

Low Pressure Setting 78 dBa

High Pressure Setting 91 dBa

At 100 psi (0.7 MPa, 7.0 bar) and full flow

Low Pressure Setting 90 dBa

High Pressure Setting 102 dBa

Sound Pressure (tested 3.28 ft [1 m] from equipment)

At 70 psi (0.48 MPa, 4.8 bar) and 50 cpm

Low Pressure Setting 84 dBa

High Pressure Setting 96 dBa

At 100 psi (0.7 MPa, 7.0 bar) and full flow

Low Pressure Setting 84 dBa

High Pressure Setting 96 dBa

Wetted parts aluminum plus the material(s) chosen for seat, ball,

and diaphragm options. Non-wetted external parts aluminum, coated carbon steel

Fluid Temperature Range

NOTICE

Temperature limits are based on mechanical stress only. Certain chemicals will further limit the fluid operating temperature range. Stay within the temperature range of the most-restricted wetted component. Operating at a fluid temperature that is too high or too low for the components of your pump may cause equipment damage.

Diaphragm/Ball Material Fahrenheit Celsius

Santoprene® (SP) -40° to 180°F -40° to 82°C

Technical Data · Fluid Temperature Range

Page 22 of the Graco 334014A user manual — Graco Information
Page 22 · click to enlarge
Page 22

Graco Standard Husky Pump Warranty

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of five years from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.

This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.

This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.

THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.

Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within six (6) years of the date of sale..

GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties..

In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.

FOR GRACO CANADA CUSTOMERS

The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.

Graco Information

For the latest information about Graco products, visit www.graco.com For patent information, see www.graco.com/patents

To place an order, contact your Graco Distributor or call to identify the nearest distributor.

Phone612-623-6921 or Toll Free: 1-800-328-0211 Fax: 612-378-3505

All written and visual data contained in this document reflects the latest product information available at the time of publication.

Graco reserves the right to make changes at any time without notice.

Original Instructions. This manual contains English. MM 334014

Graco HeadquartersMinneapolis International Offices: Belgium, China, Japan, Korea
  • GRACO INC. AND SUBSIDIARIES
  • P.O. BOX 1441
  • MINNEAPOLIS MN 55440-1441
  • USA

Copyright 2014, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.

www.graco.com

Sources

References & links

Pages referenced in this manual — manufacturer, support and downloads.

Ask about the Graco 334014A

Owners and our team usually reply within a day — and your question helps the next person too.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
No questions yet about the Graco 334014A

Be the first to ask — other owners or our team will answer.

Original document

Graco 334014A manual PDF

22 pages·4.1 MB·Marine Sanitation System·PDF
Click any page above to open it here
Page 1 / …
100%
Loading pages…