Husky ™1050HP 2:1
Air-Operated Diaphragm Pump 334014A EN
1–inch high-pressure pump with modular air valve for fluid transfer applications. For professional use only.

PROVEN QUALITY. LEADING TECHNOLOGY.


Distributor Note
a. Use the 20–digit number from the ID plate on the pump.
b. Use the Configuration Number Matrix on the next page to understand which parts are described by each digit.
c. Use the Repair/Parts Manual. Refer to the main Parts illustration and to the Parts/Kits Quick Reference. Follow the page references on these two pages for further ordering information, as needed.
Please call your distributor.
Please call your distributor.
Ordering Information


Check the identification plate (ID) for the 20–digit Configuration Number of your pump. Use the following matrix to define the components of your pump.
Sample Configuration Number:


Configuration Number Matrix

The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclamation point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
Flammable fumes, such as solvent and paint fumes, in work area can ignite or explode. To help prevent fire and explosion:
Fluid from the equipment, leaks, or ruptured components can splash in the eyes or on skin and cause serious injury.



The Typical Floor Mount Installation, page 12, is only a guide for selecting and installing system components. Contact your Graco distributor for assistance in planning a system to suit your needs.

The equipment must be grounded to reduce the risk of static sparking. Static sparking can cause fumes to ignite or explode. Grounding provides an escape wire for the electric current.
Before using the pump for the first time, check and retorque all external fasteners. Follow Torque Instructions, page 16. After the first day of operation, retorque the fasteners.

Figure 1 Grounding Screws and Wires

gauge to control the fluid pressure. The fluid stall pressure will be the same as the setting of the air regulator.
Trapped air can cause the pump to cycle unexpectedly, which could result in serious injury from splashing.
Check your system electrical continuity after the initial installation, and then set up a regular schedule for checking continuity to be sure proper grounding is maintained.
See Typical Floor Mount Installation, page 12

The air exhaust port is 3/4 npt(f). Do not restrict the air exhaust port. Excessive exhaust restriction can cause erratic pump operation.
To provide a remote exhaust:

Figure 2 Vent exhaust air
A Air supply line G Optional needle valve for pump speed adjustment.
B Bleed-type master air valve T Muffler
C Air filter/regulator U Grounded air exhaust hose
D Air inlet V Container for remote air exhaust
E Master air valve (for accessories)

Fluid Outlet Line
See Typical Floor Mount Installation, page 12
See Typical Floor Mount Installation, page 12.
1050HP — Aluminum Manifolds
The fluid inlet and outlet manifolds each have two 1 in. npt(f) or bspt threaded ports (M, N). Close off the unused port using the supplied plugs.
1050HP — Stainless Steel Manifolds
The fluid inlet and outlet manifolds each have one 1 in. npt(f) or bspt port.


Figure 3 Typical floor mount installation
A Air supply line J Fluid drain valve (required)
B Bleed-type master air valve (required for pump)
K Fluid shutoff valve
C Air filter and regulator L Flexible fluid outlet hose
D Air inlet M Fluid inlet (2 ports on aluminum manifolds,1 port on SST manifolds)
E Master air valve (for accessories) N Fluid outlet (2 ports on aluminum manifolds,1 port on SST manifolds)
F Flexible fluid suction hose R Ground wire (required; see Grounding, page 8 ).
G Optional needle valve for pump speed adjustment.


Follow the Pressure Relief Procedure whenever you see this symbol.
Before using the pump for the first time, check and retorque all external fasteners. Follow Torque Instructions, page 16. After the first day of operation, retorque the fasteners.
This equipment stays pressurized until pressure is relieved manually. To help prevent serious injury from pressurized fluid, such as splashing in the eyes or on skin, follow the Pressure Relief Procedure when you stop pumping and before you clean, check, or service the equipment.
The pump was tested in water. If water could contaminate the fluid you are pumping, flush the pump thoroughly with a compatible solvent. See Flushing and Storage, page 15.

Use the High/Low lever to set the desired pressure mode. When the lever is set to “Low,” the fluid outlet pressure is slightly less than the air inlet pressure. When the lever is set to “High,” the fluid outlet pressure is slightly less than two times the inlet air pressure. Note that the High pressure setting increases both fluid outlet pressure and inlet air consumption.
Operation

Excessive fluid inlet pressure can reduce diaphragm life and may result in pump damage.
At the end of the work shift and before you check, adjust, clean or repair the system, follow the Pressure Relief Procedure, page 13.
Operation

Flushing and Storage
Establish a preventive maintenance schedule, based on the pump’s service history. Scheduled maintenance is especially important to prevent spills or leakage due to diaphragm failure.
The pump is lubricated at the factory. It is designed to require no further lubrication for the life of the pump. An inline lubricator is not needed, and is not recommended, under normal operating conditions.
Flush the pump often enough to prevent the fluid you are pumping from drying or freezing in the pump and damaging it. Use a compatible solvent.
Before each use, check all hoses for wear or damage, and replace as necessary. Check to be sure all threaded connections are tight and leak-free. Check fasteners. Tighten or retorque as necessary. Although pump use varies, a general guideline is to retorque fasteners every two months. See Torque Instructions, page 16.
Always flush the pump and relieve the pressure before storing it for any length of time.
Maintenance

Fluid cover, center diaphragm joint, and manifold fasteners: 100 in-lb (11.3 N•m)
Lubricate air valve fasteners prior to reassembly to prevent galling. Retorque the air valve fasteners in a crisscross pattern to specified torque.
If fluid cover, center diaphragm joint, or manifold fasteners have been loosened, it is important to torque them using the following procedure to improve sealing.

Start all fluid cover or center diaphragm joint screws a few turns. Then turn down each screw just until head contacts cover. Then turn each screw by 1/2 turn or less working in a crisscross pattern to specified torque. Repeat for manifolds.


Fluid Covers and Center Diaphragm Joint Manifolds
Maintenance · Air Valve Fasteners

Aluminum SST Aluminum and SST
A 12.7 in (323 mm) 11.8 in (300 mm) H 6.2 in (157 mm)
B 14.4 in (366 mm) 12.9 in (328 mm) J 9.4 in (239 mm)
C 15.3 in (389 mm) 13.7 in (348 mm) K 15.6 in (396 mm)
D 10.9 in (277 mm) 9.5 in (241 mm) L 3/4 npt(f) Air Inlet
E 1.8 in (46 mm) 1.1 in (28 mm) M 1 in npt(f) or 1 in. bspt Fluid Inlet (2 for aluminum manifolds; 1 for SST manifolds) F 10.8 in (274 mm) 10.7 in (272 mm) N 1 in npt(f) or 1 in. bspt Fluid Outlet (2 for aluminum manifolds; 1 for SST manifolds) G 21.5 in (546 mm) 20.6 in (523 mm) P 3/4 npt(f) Air Exhaust Port


Dimensions and Mounting

Fluid Pressure
Approximate Cycles per Minute
56 112 168 224 280
100 (0.70, 7.0)
80 (0.55, 5.5)
60 (0.41, 4.1)
A 100 psi (0.7 MPa, 7.0 bar)
40 (0.28, 2.8)
B 70 psi (0.48 MPa, 4.8 bar)
20 (0.14, 1.4)
C 40 psi (0.28 MPa, 2.8 bar)
D 20 psi (0.14 MPa, 1.4 bar)
Fluid Flow — gpm (lpm)
How to Read the Charts
Approximate Cycles per Minute
56 112 168 224 280
75 (2.1)
60 (1.7)
45 (1.3)
scfm (Nm3/min.)
30 (0.8)
15 (0.4)
Fluid Flow — gpm (lpm)

Fluid Pressure
Approximate Cycles per Minute
50 100 150 200 250
200 (1.38, 13.8)
160 (1.10, 11.0)
120 (0.83, 8.3)
A 100 psi (0.7 MPa, 7.0 bar)
80 (0.55, 5.5)
B 70 psi (0.48 MPa, 4.8 bar)
40 (0.28, 2.8)
C 40 psi (0.28 MPa, 2.8 bar)
D 20 psi (0.14 MPa, 1.4 bar)
Fluid Flow — gpm (lpm)
How to Read the Charts
Approximate Cycles per Minute
50 100 150 200 250
120 (3.4)
96 (2.7)
72 (2.0)
scfm (Nm3/min.)
48 (1.4)
24 (0.7)
Fluid Flow — gpm (lpm)

Maximum fluid working pressure 200 psi 1.4 MPa,14.0 bar
Air pressure operating range 20-100 psi 0.14-0.69 MPa, 1.4-6.9 bar
Fluid displacement per cycle
Low Pressure Setting 0.17 g 0.64 l
High Pressure Setting 0.20 g 0.76 l
Air consumption at 70 psi, 20 gpm at 4.8 bar, 76 lpm
Low Pressure Setting 26 scfm 0.7 cubic meters per minute
High Pressure Setting 51 scfm 1.4 cubic meters per minute
Maximum values with water as media under submerged inlet conditions at ambient temperature:
Low Pressure Setting 59 scfm 1.7 cubic meters per minute
High Pressure Setting 95 scfm 2.7 cubic meters per minute
Low Pressure Setting 50 gpm 189 lpm
High Pressure Setting 46 gpm 174 lpm
Low Pressure Setting 280 cpm
High Pressure Setting 225 cpm
Maximum suction lift (varies widely based on ball/seat selection and wear, operating speed, material properties, and other variables)
16 ft dry, 29 ft wet 4.9 m dry 8.8 m wet
Maximum size pumpable solids 1/8 in 3.2 mm
Recommended cycle rate for continuous use
93–140 cpm (in Low or High pressure setting) Recommended cycle rate for circulation systems
20 cpm (in Low or High pressure setting) Air inlet size 3/4 npt(f)
Fluid inlet size 1 in. npt(f) or 1 in. bspt
Fluid outlet size 1 in. npt(f) or 1 in. bspt
Weight 48 lb (aluminum manifolds) 60 lb (SST manifolds) 21.8 kg (aluminum manifolds) 27.2 kg (SST manifolds)

Sound Power (measured per ISO-9614–2)
At 70 psi (0.48 MPa, 4.8 bar) and 50 cpm
Low Pressure Setting 78 dBa
High Pressure Setting 91 dBa
At 100 psi (0.7 MPa, 7.0 bar) and full flow
Low Pressure Setting 90 dBa
High Pressure Setting 102 dBa
Sound Pressure (tested 3.28 ft [1 m] from equipment)
At 70 psi (0.48 MPa, 4.8 bar) and 50 cpm
Low Pressure Setting 84 dBa
High Pressure Setting 96 dBa
At 100 psi (0.7 MPa, 7.0 bar) and full flow
Low Pressure Setting 84 dBa
High Pressure Setting 96 dBa
Wetted parts aluminum plus the material(s) chosen for seat, ball,
and diaphragm options. Non-wetted external parts aluminum, coated carbon steel
Temperature limits are based on mechanical stress only. Certain chemicals will further limit the fluid operating temperature range. Stay within the temperature range of the most-restricted wetted component. Operating at a fluid temperature that is too high or too low for the components of your pump may cause equipment damage.
Diaphragm/Ball Material Fahrenheit Celsius
Santoprene® (SP) -40° to 180°F -40° to 82°C
Technical Data · Fluid Temperature Range

Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of five years from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within six (6) years of the date of sale..
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties..
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com For patent information, see www.graco.com/patents
To place an order, contact your Graco Distributor or call to identify the nearest distributor.
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
Original Instructions. This manual contains English. MM 334014
Copyright 2014, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
Pages referenced in this manual — manufacturer, support and downloads.
Owners and our team usually reply within a day — and your question helps the next person too.
Be the first to ask — other owners or our team will answer.